Abstract: Peristaltic pumping is an inherently delicate fluids such as blood. They are also
multiphysics problem where the deformation of useful for applications requiring rugged pumps
the tube and the pumped fluid are strongly with minimal maintenance. They are used in a
coupled. We used COMSOL Multiphysics to wide range of industries including
investigate the performance of a 180 degree pharmaceutical, petrochemical, biomedical and
rotary peristaltic pump with two metallic rollers, food processing.
and an elastomeric tube pumping a viscous
The optimal peristaltic pump design depends
Newtonian fluid. The model captures the
on the application, and most specifically on the
peristaltic flow, the flow fluctuations that result
nature of the fluid and the desired flow rate. The
when the rollers engage and disengage the tube,
main design variables governing pump
and the contact interaction between the rollers
performance are the pump speed, inner tube
and the tube. We are using the model to
diameter, tube material, degree of tube occlusion,
investigate the effect of pump design variations
and back pressure. In general, increasing pump
such as tube occlusion, tube diameter, and roller
speed, inner tube diameter, and occlusion
speed, on the flow rate, flow fluctuations, and
increases the flow rate. Increasing fluid viscosity
stress state in the tube.
reduces the flow rate. Tube failure due to the
high stress cyclic loading is one of the main
Keywords: Fluid-structure interaction,
constraints on pump performance.
peristaltic pumping, multiphysics, nonlinear
material, pump modeling
2. Literature Review
1. Introduction
Most analyses on peristaltic pumps are
performed using empirical relations or analytical
A peristaltic pump is a type of positive
equations based on idealized flow and pump
displacement pump that moves fluid by
geometry, and are valid for a specific range of
squeezing a tube or hose causing the fluid inside
Reynolds numbers1,2. Numerical simulations
to follow the motion of the roller. Peristaltic
have been performed based on lubrication
pumps are valuable for pumping abrasive or
theory3, and CFD4,5. In most cases displacement
corrosive fluids that could damage or
of the fluid wall is explicitly assumed.
contaminate rotors or gears and for pumping
Solid contours: Mises stress
Fluid arrows: Velocity field