Sei sulla pagina 1di 1

Operating 1. Safety against being blocked by debris and dirt.

With
instructions GB safety pressure gauges (see dial symbol k) it
WARNING! must be ensured that the free space behind the
Before installation, commission- blow-out back is at least 15 mm.
ing and operation, ensure that the
Pressure gauges appropriate pressure gauge has been After mounting, set the compen-
selected in terms of measuring range, sating valve (if available) from
design and suitable wetted material (corrosion) CLOSE to OPEN.
for the specific measuring conditions. In order to With models 4 and 7, do not open the flange
Examples: guarantee the measuring accuracy and long-term mounting screws.
stability specified, the corresponding load limits
must be observed. Requirements for the installation point

Only qualified persons authorised by the plant If the line to the gauge is not sufficiently rigid for
manager are permitted to install, maintain and vibration-free mounting, a pipe-support bracket
Model 732.14, service the pressure gauges. should be used to secure it (possibly via a
overpressure safety flexible capillary). If vibration cannot be prevented
up to 400 bar For hazardous media such as oxygen, acetylene, through suitable installation, liquid-filled gauges
Model 432.56, flammable or toxic gases or liquids, and refrigera- should be used. The instruments should be
overpressure safety tion plants, compressors, etc., in addition to all protected against coarse dirt and wide fluctua-
up to 100 bar standard regulations, the appropriate existing tions in ambient temperature.
codes or regulations must also be followed. Note for model 732.14 for front bezel mounting:
Model 213.40
The front bezel serves as centring and as the
After an external fire, pressure media can leak aperture in the mounting panel.
out, particularly at soft solder joints. All gauges Securing and thus the weight-bearing must be
must be checked and, if necessary, replaced made via the pressure connection piping.
before recommissioning the plant.
3. Permissible ambient and operating
Non-observance of the respective regulations temperatures
Notes in accordance with Pressure Equipment can result in serious injury and/or damage to
Directive 97/23/EC equipment. When mounting the pressure gauge it must be
„„ The pressure gauges are "pressure accessories" ensured that, taking into consideration the influ-
2. Mechanical connection ence of convection and heat radiation, no devia-
in accordance with Article 1, Paragraph 2.1.4
„„ The volume of the pressure bearing housings of tion above or below the permissible ambient and
In accordance with the general technical regula- medium temperatures can occur. The influence
WIKA pressure gauges is < 0.1 L
tions for pressure gauges (e.g. EN 837-2). When of temperature on the display accuracy must be
„„ The pressure gauges carry CE marking for Fluid
screwing the gauges in the force required for this observed.
Group 1G in accordance with Annex 2, Table 1
must not be applied through the case or termi-
when their permissible working pressure
nal box, rather only through the spanner flats 4. Storage
exceeds 200 bar
provided for this purpose (using a suitable tool).
Pressure gauges that do not carry the CE mark
are manufactured in accordance with Article 3, The pressure gauge should be kept in its original
Paragraph 3 "Sound engineering practice". packing until installation. The gauge should be
Mounting with
protected from external damage during storage.
Applied standards spanner
Storage temperature range: -40 ... +70 °C.
EN 837-1 Bourdon tube pressure gauges, dimensions, Protect the gauges from humidity and dust.
metrology, requirements and testing
EN 837-2 Selection and installation recommendations Correct sealing of pressure gauge connections
with parallel threads  must be made using 5. Maintenance and repairs
for pressure gauges
EN 837-3 Diaphragm and capsule pressure gauges, suitable sealing rings, sealing washers or WIKA
profile seals. The sealing of tapered threads (e.g. The instruments are maintenance-free. Checks
dimensions, metrology, requirements and should be carried out on a regular basis to ensure
testing NPT threads) is made by providing the thread
 with additional sealing material such as, for the measuring accuracy of the pressure gauge.
Specifications: see data sheet on www.wika.de example, PTFE tape (EN 837-2). The checks or recalibrations must be carried out
by qualified skilled personnel with the appropriate
Subject to technical modifications. equipment.
© WIKA Alexander Wiegand SE & Co. KG 2009 Sealing by When dismounting, close the compensating valve
Spanner flats the thread (if available).

Sealing face 
WARNING!
Residual media in dismounted
2408976.04 11/2013

WIKA Alexander Wiegand SE & Co. KG pressure gauges can result in a risk
Alexander-Wiegand-Straße 30 The torque depends on the seal used. Connect- to personnel, the environment and
63911 Klingenberg/Germany ing the gauge using a clamp socket or a union nut equipment. Take sufficient precaution-
Tel. +49 9372 132-0 is recommended, so that it is easier to orientate ary measures.
Fax +49 9372 132-406 the gauge correctly. When a blow-out device is
info@wika.de fitted to a pressure gauge, it must be protected
www.wika.de

Potrebbero piacerti anche