Type : A318/A319/A320/A321 Selected applicability : ALL


Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

** ON A/C ALL

TASK 28-11-00-790-802-A
Leak Test of the Wing Tanks and the Center Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN
CAUSE DAMAGE TO THE EQUIPMENT.

WARNING: MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.

1. Reason for the Job


Self explanatory
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTY DESIGNATION


No specific AR ACCESS PLATFORM 6M (20 FT)
No specific AR SAFETY BARRIER(S)
No specific AR WARNING NOTICE(S)
(98D27803000000) 1 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
(DETTPS8001) 1
(DETTPSH0AI00) 1 AIRBUS HOLDER FOR VENT PLUGS
(DETTPSTAAI001) 1 DRAIN-WATER, INTERFACES

** ON A/C 001-010
(DETTPSVPAI04) 1 VENT PLUG KIT

** ON A/C 011-300
(DETTPSVPAI07) 1 PLUGS-NACA VENT

** ON A/C ALL
(DETW40052) 1

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


140 CENTER WING
540 FUEL TANK
550 VENT SURGE TANK
640 FUEL TANK
650 VENT SURGE TANK

C. Referenced Information

Print Date: January 09, 2018 Page 1 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

REFERENCE DESIGNATION
(Ref. 12-11-28-650-003-A). Pressure Refuel with Automatic Control
(Ref. 12-34-24-869-001-B). Aircraft Bonding and Grounding (Earthing) for the Refuel/Defuel or
Oxygen Servicing Operations
(Ref. 24-41-00-861-002-A). Energize the Aircraft Electrical Circuits from the External Power
(Ref. 24-41-00-861-002-A-01). Energize the Aircraft Electrical Circuits from the APU
(Ref. 24-41-00-861-002-A-02). Energize the Aircraft Electrical Circuits from Engine 1(2)
(Ref. 24-41-00-862-002-A). De-energize the Aircraft Electrical Circuits Supplied from the External
Power
(Ref. 24-41-00-862-002-A-01). De-energize the Aircraft Electrical Circuits Supplied from the APU
(Ref. 24-41-00-862-002-A-02). De-energize the Aircraft Electrical Circuits Supplied from the Engine
1(2)
(Ref. 27-50-00-866-008-A). Extension of the Flaps on the Ground
(Ref. 27-50-00-866-008-A-01). Extension of the Flaps/Slats on the Ground
(Ref. 27-50-00-866-009-A). Retraction of the Flaps on the Ground
(Ref. 27-50-00-866-009-A-01). Retraction of the Flaps/Slats on the Ground
(Ref. 27-80-00-866-004-A). Extending the Slats on the Ground
(Ref. 27-80-00-866-005-A). Retracting the Slats on the Ground
(Ref. 28-10-00-910-001-A). Safety Procedures When You Do Work in a Fuel Tank
(Ref. 28-10-00-910-002-A). Access to the Fuel Tanks and the Work Areas
(Ref. 28-11-00-790-009-A). Leak Test of the Fuel Tanks - Without Fuel - Helium Procedure
(Ref. 28-12-41-200-003-A). Inspection of the Overpressure Protector
(Ref. 28-25-00-650-001-A). Pressure Defuel
(Ref. 28-25-00-650-003-A). To Drain Remaining Fuel from the Wing Tanks and the Center Tank
(Ref. 28-25-00-650-003-A-01). To Drain Remaining Fuel from the Wing Tanks and the Center Tank
(Ref. 31-60-00-860-001-A). EIS Start Procedure
(Ref. 31-60-00-860-002-A). EIS Stop Procedure
(Ref. 51-76-12-300-001-A). Local Repair of the Fuel Tank Sealant
(Ref. 57-27-11-400-001-A). Installation of the Access Panel
(Ref. 57-27-11-400-002-A). Installation of the Access Panel
Helium Mapping Kit - Left Wing Tank and Center Tank - Connections SHEET 1
Helium Mapping Kit - Right Wing Tank - Connections SHEET 1

Print Date: January 09, 2018 Page 2 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

TPS

AIR/HELIUM
SUPPLY
Fans Pressurization System

TANK PRESSURE
MEASUREMENT

NOTE:
1. WATER DRAIN-VALVE ADAPTER
2. NACA PLUG
3. NACA PLUG HOLDER
4. CONTROL UNIT

N_MM_281100_5_NAM0_01_00

Figure 28-11-00-991-04100-00-A / SHEET 1/1 - Helium


Mapping Kit - Left Wing Tank and Center Tank - Connections
** ON A/C ALL

Print Date: January 09, 2018 Page 3 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

TPS

AIR/HELIUM
SUPPLY
Fans Pressurization System

2
TANK PRESSURE
MEASUREMENT

NOTE:
1. WATER DRAIN-VALVE ADAPTER
2. CONTROL UNIT
3. NACA PLUG HOLDER
4. NACA PLUG

N_MM_281100_5_NBM0_01_00

Figure 28-11-00-991-04200-00-A / SHEET 1/1 - Helium Mapping Kit - Right Wing Tank - Connections
** ON A/C ALL

Print Date: January 09, 2018 Page 4 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

3. Job Set-up
Subtask 28-11-00-941-119-A
A. Safety Precautions

WARNING: OBEY THE SAFETY PROCEDURES WHEN YOU DO WORK IN A FUEL TANK.

(1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-
00-910-001) .
(2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flight controls.
(3) Put the LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION (98D27803000000) on the slat/flap
control lever.
(4) Put the SAFETY BARRIER(S) in position.
Subtask 28-11-00-860-129-A
B. Aircraft Maintenance Configuration
(1) Make sure that the aircraft is grounded (earthed) correctly (Ref. AMM TASK 12-34-24-869-001) .
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) .
(3) In the cockpit:
(a) On the panel 25VU, make sure that the APU MASTER SW P/BSW is in the off position (the ON
legend is off).
(b) On the panel 115VU, make sure that the ENG/MASTER 1 and ENG/MASTER 2 switches are in
the OFF position.
(c) On the panel 40VU, make sure that the X FEED P/BSW is released (the ON legend is off).
(4) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001) , then:
· On the ECAM control panel (CP), push (in) the FUEL P/BSW
· Make sure that the FUEL page shows on the ECAM lower display unit (DU).
(5) On the ECAM lower DU, make sure that:
· The engine LP valves are shown closed (amber cross-line)
· The APU LP valve shows closed (green crossed line)
· The X FEED valve shows closed (green crossed line).
(6) On the refuel/defuel panel 800VU, make sure that:
· The MODE SELECT switch is in the OFF and guarded position
· All the REFUEL VALVE switches are in the SHUT position.
(7) Defuel the applicable fuel tank(s) (Ref. AMM TASK 28-25-00-650-001) .
(8) Drain the remaining fuel from the applicable fuel tank(s) (Ref. AMM TASK 28-25-00-650-003) .
(9) Fully extend the flaps and the slats (Ref. AMM TASK 27-50-00-866-008) and (Ref. AMM TASK 27-
80-00-866-004) .
(10) Make sure that the LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION (98D27803000000) is
installed on the slat/flap control lever.
(11) Make sure that the applicable overpressure protector on each NACA inlet is serviceable
(Ref. AMM TASK 28-12-41-200-003) .
(12) Make sure that the manhole access panels of all wing tanks are installed correctly
(Ref. AMM TASK 57-27-11-400-001) and (Ref. AMM TASK 57-27-11-400-002) .
(13) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002) .

Print Date: January 09, 2018 Page 5 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

(14) De-energize the aircraft electrical circuits


(Ref. AMM TASK 24-41-00-862-002) .
Subtask 28-11-00-010-092-A
C. Get Access
(1) Put the ACCESS PLATFORM 6M (20 FT) in position below the applicable access panel.
(2) Remove the applicable access panels.
(a) To get access to the front of the fuel tank, remove the applicable wing leading-edge access-
panels.
(b) To get access to the rear of the fuel tank, remove the applicable wing trailing-edge access-
panels.
(c) To get access to the center tank, remove the applicable belly fairing access-panel.
4. Procedure

** ON A/C 001-010
Subtask 28-11-00-790-098-A

CAUTION: MAKE SURE THAT THE MAXIMUM PRESSURE IN THE TANK IS NOT MORE THAN 0.1378
BAR (2.0 PSI). THIS WILL PREVENT DAMAGE TO THE FUEL SYSTEM.

A. Leak Test of the Left Wing Tank and the Center Tank - Without Fuel - Pressurized Air and Helium/Air
Procedure
(Ref. Fig. Helium Mapping Kit - Left Wing Tank and Center Tank - Connections SHEET 1)

NOTE: To do the test, use the applicable items from:


- The (DETTPS8001)
- The (DETW40052)
- The VENT PLUG KIT (DETTPSVPAI04)
- The AIRBUS HOLDER FOR VENT PLUGS (DETTPSH0AI00) and
- The DRAIN-WATER, INTERFACES (DETTPSTAAI001) .

(1) Connect the compressed air supply to the control unit (4).
(2) Connect the power supply and set the control unit (4) switch to the ON position.
(3) Install the NACA plug holder (3) on the NACA plug (2).
(4) Install the NACA plug (2) on the left-wing NACA inlet.
(5) Make sure that the NACA plug (2) is connected to the control unit (4).
(6) Connect the water drain-valve adapter (1) from the control unit (4) to the water drain valve 25QM.
(7) Do an air leak test as follows:
(a) Operate the control unit (4) to start the air test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(b) When the pressure has got to 0.10 bar (1.5 psi), monitor the pressure in the tank(s) for a period
of 10 minutes.
(c) If the pressure in the tank(s) decreases to less than 0.09 bar (1.3 psi), find the exit point of the
leak.

Print Date: January 09, 2018 Page 6 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

NOTE: The control unit (4) will keep the air pressure supplied to help to find the exit point of the
leak.

(d) Listen around the tank(s) boundaries for any hissing sounds of air pressure leak.
(e) If a hissing sound is heard, repair the leak.
(f) If the pressure in the tank(s) is stable at 0.09 bar (1.3 psi), operate the control unit (4) to
depressurize the tank(s).
(g) Make sure that the pressure in the tank(s) is back to atmospheric pressure.
(8) Do the air/helium leak test as follows:
(a) Connect the helium supply to the control unit (4).
(b) Set the control unit (4) to supply the air and the helium to the tank(s).
(c) Operate the control unit (4) to start the test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(d) Wait for 10 minutes to let the helium mix with the air in the tank(s). This makes sure that there is
approximately 10 percent helium and 90 percent air.
(e) Use the portable helium detector to find the leak point on external surfaces of the tank(s).

NOTE: A fuel leak can move for a long distance in the aircraft structure. Compressed air can be
used to remove the helium build up in the area. This will make it easier to find the point of
the leak.

(f) Make a mark at each exit point as you find them.

NOTE: This will help you to find them when you do a leak test to find the source of the leak.

NOTE: The exit point of leakage can be at a long distance from the source of the leak.

NOTE: Air/helium can leak through the system valves and effect the test results.

(g) Operate the control unit (4) to depressurize the tank(s).


(h) Make sure that the pressure in the tank(s) is fully released before you continue.
(i) Get access to the applicable fuel tank(s) (Ref. AMM TASK 28-10-00-910-002) .
1 Make sure that the remaining helium content in the tank(s) is fully removed, to prevent the
background signal.
(j) Do a leak test at each of the exit points where you made a mark (Ref. AMM TASK 28-11-00-
790-009) .
(k) At source of each leak:
1 Do the necessary repair procedure (Ref. AMM TASK 51-76-12-300-001) .
2 Do the step (8) again to make sure that the leak is repaired.
(9) Remove the NACA plug (2) from the left-wing NACA inlet.
(10) Remove the NACA plug holder (3) from the NACA plug (2).
(11) Remove the water drain-valve adapter (1) from the water drain valve 25QM.
(12) Disconnect the compressed air supply and the helium supply from the control unit (4).

Print Date: January 09, 2018 Page 7 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

Subtask 28-11-00-790-099-A

CAUTION: MAKE SURE THAT THE MAXIMUM PRESSURE IN THE TANK IS NOT MORE THAN 0.1378
BAR (2.0 PSI). THIS WILL PREVENT DAMAGE TO THE FUEL SYSTEM.

B. Leak Test of the Right Wing Tank - Without Fuel - Pressurized Air and Helium/Air Procedure
(Ref. Fig. Helium Mapping Kit - Right Wing Tank - Connections SHEET 1)

NOTE: To do the test, use the applicable items from:


- The (DETTPS8001)
- The (DETW40052)
- The VENT PLUG KIT (DETTPSVPAI04)
- The AIRBUS HOLDER FOR VENT PLUGS (DETTPSH0AI00) and
- The DRAIN-WATER, INTERFACES (DETTPSTAAI001) .

(1) Connect the compressed air supply to the control unit (2).
(2) Connect the power supply and set the control unit (2) switch to the ON position.
(3) Install the NACA plug holder (3) on the NACA plug (4).
(4) Install the NACA plug (4) on the right-wing NACA inlet.
(5) Make sure that the NACA plug (4) is connected to the control unit (2).
(6) Connect the water drain-valve adapter (1) from the control unit (2) to the water drain valve 26QM.
(7) Do an air leak test as follows:
(a) Operate the control unit (2) to start the air test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(b) When the pressure has got to 0.10 bar (1.5 psi), monitor the pressure in the tank for a period of
10 minutes.
(c) If the pressure in the tank decreases to less than 0.09 bar (1.3 psi), find the exit point of the leak.

NOTE: The control unit (2) will keep the air pressure supplied to help to find the exit point of the
leak.

(d) Listen around the tank boundaries for any hissing sounds of air pressure leak.
(e) If a hissing sound is heard, repair the leak.
(f) If the pressure in the tank is stable at 0.09 bar (1.3 psi), operate the control unit (2) to
depressurize the tank.
(g) Make sure that the pressure in the tank is back to atmospheric pressure.
(8) Do the air/helium leak test as follows:
(a) Connect the helium supply to the control unit (2).
(b) Set the control unit (2) to supply the air and the helium to the tank.
(c) Operate the control unit (2) to start the test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(d) Wait for 10 minutes to let the helium mix with the air in the tank. This makes sure that there is
approximately 10 percent helium and 90 percent air.

Print Date: January 09, 2018 Page 8 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

(e) Use the portable helium detector to find the leak point on external surfaces of the tank.

NOTE: A fuel leak can move for a long distance in the aircraft structure. Compressed air can be
used to remove the helium build up in the area. This will make it easier to find the point of
the leak.

(f) Make a mark at each exit point as you find them.

NOTE: This will help you to find them when you do a leak test to find the source of the leak.

NOTE: The exit point of leakage can be a long distance from the source of the leak.

NOTE: Air/helium can leak through the system valves and effect the test results.

(g) Operate the control unit (2) to depressurize the tank.


(h) Make sure that the pressure in the tank is fully released before you continue.
(i) Get access to the applicable fuel tank(s) (Ref. AMM TASK 28-10-00-910-002) .
1 Make sure that the remaining helium content in the tank is fully removed, to prevent the
background signal.
(j) Do a leak test at each of the exit points where you made a mark (Ref. AMM TASK 28-11-00-
790-009) .
(k) At source of each leak:
1 Do the necessary repair procedure (Ref. AMM TASK 51-76-12-300-001) .
2 Do the step (8) again to make sure that the leak is repaired.
(9) Remove the NACA plug (4) from the right-wing NACA inlet.
(10) Remove the NACA plug holder (3) from the NACA plug (4).
(11) Remove the water drain-valve adapter (1) from the water drain valve 26QM.
(12) Disconnect the compressed air supply and the helium supply from the control unit (2).

** ON A/C 011-300
Subtask 28-11-00-790-098-B

CAUTION: MAKE SURE THAT THE MAXIMUM PRESSURE IN THE TANK IS NOT MORE THAN 0.1378
BAR (2.0 PSI). THIS WILL PREVENT DAMAGE TO THE FUEL SYSTEM.

A. Leak Test of the Left Wing Tank and the Center Tank - Without Fuel - Pressurized Air and Helium/Air
Procedure
(Ref. Fig. Helium Mapping Kit - Left Wing Tank and Center Tank - Connections SHEET 1)

NOTE: To do the test, use the applicable items from:


- The (DETTPS8001)
- The (DETW40052)
- The PLUGS-NACA VENT (DETTPSVPAI07)
- The AIRBUS HOLDER FOR VENT PLUGS (DETTPSH0AI00) and
- The DRAIN-WATER, INTERFACES (DETTPSTAAI001) .

(1) Connect the compressed air supply to the control unit (4).
(2) Connect the power supply and set the control unit (4) switch to the ON position.

Print Date: January 09, 2018 Page 9 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

(3) Install the NACA plug holder (3) on the NACA plug (2).
(4) Install the NACA plug (2) on the left-wing NACA inlet.
(5) Make sure that the NACA plug (2) is connected to the control unit (4).
(6) Connect the water drain-valve adapter (1) from the control unit (4) to the water drain valve 25QM.
(7) Do an air leak test as follows:
(a) Operate the control unit (4) to start the air test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(b) When the pressure has got to 0.10 bar (1.5 psi), monitor the pressure in the tank(s) for a period
of 10 minutes.
(c) If the pressure in the tank(s) decreases to less than 0.09 bar (1.3 psi), find the exit point of the
leak.

NOTE: The control unit (4) will keep the air pressure supplied to help to find the exit point of the
leak.

(d) Listen around the tank(s) boundaries for any hissing sounds of air pressure leak.
(e) If a hissing sound is heard, repair the leak.
(f) If the pressure in the tank(s) is stable at 0.09 bar (1.3 psi), operate the control unit (4) to
depressurize the tank(s).
(g) Make sure that the pressure in the tank(s) is back to atmospheric pressure.
(8) Do the air/helium leak test as follows:
(a) Connect the helium supply to the control unit (4).
(b) Set the control unit (4) to supply the air and the helium to the tank(s).
(c) Operate the control unit (4) to start the test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(d) Wait for 10 minutes to let the helium mix with the air in the tank(s). This makes sure that there is
approximately 10 percent helium and 90 percent air.
(e) Use the portable helium detector to find the leak point on external surfaces of the tank(s).

NOTE: A fuel leak can move for a long distance in the aircraft structure. Compressed air can be
used to remove the helium build up in the area. This will make it easier to find the point of
the leak.

(f) Make a mark at each exit point as you find them.

NOTE: This will help you to find them when you do a leak test to find the source of the leak.

NOTE: The exit point of leakage can be at a long distance from the source of the leak.

NOTE: Air/helium can leak through the system valves and effect the test results.

(g) Operate the control unit (4) to depressurize the tank(s).


(h) Make sure that the pressure in the tank(s) is fully released before you continue.

Print Date: January 09, 2018 Page 10 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

(i) Get access to the applicable fuel tank(s) (Ref. AMM TASK 28-10-00-910-002) .
1 Make sure that the remaining helium content in the tank(s) is fully removed, to prevent the
background signal.
(j) Do a leak test at each of the exit points where you made a mark (Ref. AMM TASK 28-11-00-
790-009) .
(k) At source of each leak:
1 Do the necessary repair procedure (Ref. AMM TASK 51-76-12-300-001) .
2 Do the step (8) again to make sure that the leak is repaired.
(9) Remove the NACA plug (2) from the left-wing NACA inlet.
(10) Remove the NACA plug holder (3) from the NACA plug (2).
(11) Remove the water drain-valve adapter (1) from the water drain valve 25QM.
(12) Disconnect the compressed air supply and the helium supply from the control unit (4).
Subtask 28-11-00-790-099-B

CAUTION: MAKE SURE THAT THE MAXIMUM PRESSURE IN THE TANK IS NOT MORE THAN 0.1378
BAR (2.0 PSI). THIS WILL PREVENT DAMAGE TO THE FUEL SYSTEM.

B. Leak Test of the Right Wing Tank - Without Fuel - Pressurized Air and Helium/Air Procedure
(Ref. Fig. Helium Mapping Kit - Right Wing Tank - Connections SHEET 1)

NOTE: To do the test, use the applicable items from:


- The (DETTPS8001)
- The (DETW40052)
- The PLUGS-NACA VENT (DETTPSVPAI07)
- The AIRBUS HOLDER FOR VENT PLUGS (DETTPSH0AI00) and
- The DRAIN-WATER, INTERFACES (DETTPSTAAI001) .

(1) Connect the compressed air supply to the control unit (2).
(2) Connect the power supply and set the control unit (2) switch to the ON position.
(3) Install the NACA plug holder (3) on the NACA plug (4).
(4) Install the NACA plug (4) on the right-wing NACA inlet.
(5) Make sure that the NACA plug (4) is connected to the control unit (2).
(6) Connect the water drain-valve adapter (1) from the control unit (2) to the water drain valve 26QM.
(7) Do an air leak test as follows:
(a) Operate the control unit (2) to start the air test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(b) When the pressure has got to 0.10 bar (1.5 psi), monitor the pressure in the tank for a period of
10 minutes.
(c) If the pressure in the tank decreases to less than 0.09 bar (1.3 psi), find the exit point of the leak.

NOTE: The control unit (2) will keep the air pressure supplied to help to find the exit point of the
leak.

(d) Listen around the tank boundaries for any hissing sounds of air pressure leak.

Print Date: January 09, 2018 Page 11 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

(e) If a hissing sound is heard, repair the leak.


(f) If the pressure in the tank is stable at 0.09 bar (1.3 psi), operate the control unit (2) to
depressurize the tank.
(g) Make sure that the pressure in the tank is back to atmospheric pressure.
(8) Do the air/helium leak test as follows:
(a) Connect the helium supply to the control unit (2).
(b) Set the control unit (2) to supply the air and the helium to the tank.
(c) Operate the control unit (2) to start the test.

NOTE: The system will automatically increase the pressure to 0.10 bar (1.5 psi).

(d) Wait for 10 minutes to let the helium mix with the air in the tank. This makes sure that there is
approximately 10 percent helium and 90 percent air.
(e) Use the portable helium detector to find the leak point on external surfaces of the tank.

NOTE: A fuel leak can move for a long distance in the aircraft structure. Compressed air can be
used to remove the helium build up in the area. This will make it easier to find the point of
the leak.

(f) Make a mark at each exit point as you find them.

NOTE: This will help you to find them when you do a leak test to find the source of the leak.

NOTE: The exit point of leakage can be a long distance from the source of the leak.

NOTE: Air/helium can leak through the system valves and effect the test results.

(g) Operate the control unit (2) to depressurize the tank.


(h) Make sure that the pressure in the tank is fully released before you continue.
(i) Get access to the applicable fuel tank(s) (Ref. AMM TASK 28-10-00-910-002) .
1 Make sure that the remaining helium content in the tank is fully removed, to prevent the
background signal.
(j) Do a leak test at each of the exit points where you made a mark (Ref. AMM TASK 28-11-00-
790-009) .
(k) At source of each leak:
1 Do the necessary repair procedure (Ref. AMM TASK 51-76-12-300-001) .
2 Do the step (8) again to make sure that the leak is repaired.
(9) Remove the NACA plug (4) from the right-wing NACA inlet.
(10) Remove the NACA plug holder (3) from the NACA plug (4).
(11) Remove the water drain-valve adapter (1) from the water drain valve 26QM.
(12) Disconnect the compressed air supply and the helium supply from the control unit (2).

** ON A/C ALL
5. Close-up
Subtask 28-11-00-410-091-A

Print Date: January 09, 2018 Page 12 of 13


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : HVN Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Nov 01, 2017
28-11-00-790-802-A - Leak Test of the Wing Tanks and the Center
Tank - Without Fuel - Pressurized Air and Helium/Air Procedure

A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) If applicable, install the wing leading-edge access-panels.
(3) If applicable, install the wing trailing-edge access-panels.
(4) If applicable, install the belly fairing access-panels.
Subtask 28-11-00-860-130-A
B. Aircraft Maintenance Configuration
(1) Refuel the applicable fuel tank(s) (Ref. AMM TASK 12-11-28-650-003) .
(2) If applicable, retract the flaps and the slats fully (Ref. AMM TASK 27-50-00-866-009) and
(Ref. AMM TASK 27-80-00-866-005) .
Subtask 28-11-00-942-122-A
C. Removal of Equipment
(1) Remove the SAFETY BARRIER(S).
(2) Remove the access platform(s).
(3) Remove the warning notice(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other
items.

End of document

Print Date: January 09, 2018 Page 13 of 13