Sei sulla pagina 1di 42

NARI

NARI SOLUTION

PT.NARI INDONESIA FOREVER


June 2018
Content

Part 01 NARI Profile


Part 02 NARI Solution
Part 03 Advantages of the NARI
Part 04 NARI Technical Description
Part 05 References
NARI
NARI Profile
Part 01 About Us
Who are we?

NARI
About Us Who are we? NARI Group Corporation

1.1 Company Profile

1.2 Business Scope

1.3 A Whole Solution Provider

1.4 Enterprise Influence


1.1 Company Profile
Part 01 Introduction
Employees
With over 17,000 employees and
covering 1,000,000 m2 area.
Market Value
Total market value of 11 billion USD and
increased 65 times since listed in SSE.
Revenue
FY 2018 revenue 5.14 billion USD.

Patents
2992 International and National
Patents
Industry Standards
Leading 15 International Standards and
112 National Standards
Ranking
Ranked NO.2 in National Enterprise
Technology Center Evaluation

NARI
1.2 Business Scope
Part 01 Introduction
Intelligent
Intelligent
Distributi Railway
on Transporta
Intelligent Intelligent tion
Transmiss Transforma
ion tion
Intelligent
Dispatch
Intelligent
Power
Consumpt
Smart ion Rail
Power Transit
Devices Automati
on
Electric
Railway
Hydroelec
tric Power
Automati
on
Green
Ports

 More than 40 product lines


 Diversified products with independent intellectual property rights
 More than 500 technical solutions
 More than 1000 creations, many of which ranked NO.1 in china
and worldwide

NARI
1.3 A Whole Solution Provider
Part 01 Introduction

R&D Engineering Manufacture Commissioning Service


NARI
1.4 Enterprise Influence
Part 01 Introduction
Activities of International Organizations
NARI is a member of the board of directors of IERE and the core group of IERE-TIS
Asia, participates actively in international organizations such as the International
Electrotechnical Commission (IEC), the International Conference on Large High
Voltage Electric System (CIGRE), the Institute of Electrical and Electronic Engineers
(IEEE), with 30 experts as important members.

Predominate Role in International Standards and Chinese Equipment


Development
NARI plays a predominate roll in 10 international standards in the technology fields
International Organization Membership of power dispatching, electrical vehicles, relay protection, and UHV transmission, of
 International Organization for Standardization(ISO) which 5 standards are released, and 6 Chinese standard schemes successfully have
 International Conference on Large High Voltage been incorporated into the IEC standard system.
Electric System(CIGRE)
 International Electrotechnical Commission(IEC)
 Institute of Electrical and Electronic Engineers(IEEE)
 International Electric Research Exchange(IERE)
 International Federation of Automatic Control(IFAC)
 International Conference on Insulated Power Cables
(JICABLE)

NARI
1.5 PT.NARI INDONESIA FOREVER Introduction
Part 01 Introduction
NARI Group Corporation open the representative’s office
PT .NARI Indonesia Forever, which is located in AIA
Central Building Jendral 25 Floor Sudirman, Jakarta.
Indonesia, and has been established since 2013.
Combining with the advanced technology and successful
experience of Chinese electrical power construction and
in accordance with Indonesian national conditions and
characteristics, PT. NARI Indonesia Forever will provide
total solutions, related products and localization service
of power generation, transmission, transformation,
distribution, new energy, information & communication,
industrial automation and other fields.

And Also PT NARI Indonesia Forever can provides EPC


services for certain projects and Integrated provider for
helping our customer with total solution.
NARI
NARI Solution

Part 02
Brief Introduction to the Solution

NARI
NARI Solution Brief Introduction to the Solution

2.1 Hardware Infrastructure 2.2 Software Infrastructure 2.3 Technical Infrastructure

NARI
2.1 Hardware Infrastructure
Part 02 : NARI Solution
 Distribution Network
• Conductors
• Pole Structure HV/MV Part
• Distribution Transformer Distribution
• Break Switches/Isolators Substation
Target:
 Substation Distribution • Automation, Reliable, Resiliency
Automation • Loss & Power Quality
• Renewable Energy Accessible
• RTU • Flexible Consumption
• DTU
• Compensation Capacitor
FTU
 Communication System
• Backbone: MPLS
• Cellular
• OLT DTU
• ONU

 Informatization
LV Part
• OMS
• GIS

 Micro-grid
Phase Switching
• BESS Switchgear
Compensation Smart Meters
EV Charger DG and BESS
Capacitor
• Distributed Energy
Access and Control

NARI
2.2 Software Infrastructure
Part 02 : NARI Solution Renewable Energy and Smart Park Management
Distributed energy Distributed energy Distribution network Smart community Smart home/Smart Smart Water/Smart
resources (DER) plug and resources (DER) cluster energy management integrated management building/Smart Energy...
play control service platform community

Distribution Distribution O&M


automation management
Primary and
secondary system Terminal plug and Technical Power
Distribution
integration play technology extension physical asset distribution
technology management repair command
Standard power
Accurate equipment
management
distribution and
utilization model parameters
Dispatching and New power Distribution Distribution
distribution distribution automatic intelligent
integration master station operation and inspection
technology technology Cloud computing, Big data, maintenance management
Intelligent Intelligent
control IoT, mobile internet, AI O&M
Distribution Distribution
Single-phase Feeder network
grounding device status
automation awareness operation
troubleshooting Comprehensive process control
Complete electrical measurement
topology information
Information Distributed energy Distribution
services resource power supply Power mobile
interaction & management management application
integration system (DERMS) Intellisense

Grid static data Grid dynamic data


Power grid Grid O&M Feeder Station Line fault Power distribution Portable Electricity Scheduling
locating equipment status mobile information ...
NARI
equipment graphics resources FTU DTU device information terminal collection system automation
2.3 Technical Infrastructure
Part 02 : NARI Solution
 Generation: Distributed Photovoltaic,
Energy Storage, CCHP(Combined
 Operation Control System
 Terminal & Smart Meter Cooling, Heating and Power)
(SCADA/EMS/DMS)
 Information and Communication  Network: Microgrid, Access and
 Microgrid Opration Control
Facilities Intelligent Supply and Distribution
Management System
 IOT Equipment Management Network
 Information System (CBS/GIS/TC)
 Load: Electric Vehicles, Shore Power,
Lighting, Air Conditioning

Information Internet of Things(IOT) Physical Energy Network

Comprehensive DER Access, Control Multi-system Information Integration of Distribution Network


Construction of and Consumption Information Integration and Primary and Energy Conservation
Distribution Interaction Based on Comprehensive Secondary Power and Energy
Automation IEC 61968 Application of Power Distribution Efficiency
Distribution and Equipment Management
Utilization
Development Focus

NARI
Advantages of the NARI

Part 03
Advantages and Opportunities of the Solution

NARI
2
Renewable

1
Less Outage and Energy Access

More Stability

3
Demand
Response

What Smart System Brings Us :


Advantages and Opportunities of the Solution

NARI
3.1 Less Outage and More Stability
Part 03:Advantages of the NARI
56.83 minute 100% 99.99%

97.89% 99.96%
10.86 minute

Average Switching Operation Time Grid Interconnect Rate Power Supply Reliability

26.92 minute Smart Distribution Bring Us in SGCC 99.95%


 By the end of 2017, the total capacity of
SGCC 110 kV and below is 28.6 billion 99.90%
3.94 minute KVA, and the total length of 110kV to
10kV lines is 4.54 million kilometers.
 The reliability of power supply for urban
Power Supply Recovery Time
in Non- Failure Area
and rural power networks is 99.948% and Voltage Qualified Rate
99.784%, respectively. 99.50%
33.94 minute
 Compared with 2010, the annual power
24.52 minute
outage time per household was
shortened by 3.7 hours and 13 hours 90.00%
respectively.
 The reliability 99.9999%, the annual
power outage time per household is less
NARI
Average Rush Repair Arrival Time Informatization Integrity
than 0.5 minutes.
3.2 Renewable Energy Access
Part 03 :Advantages of the NARI

 Wind-Solar-Storage Co-generation
• Wind Farm Control System
• Battery Storage
• Solar panel and smart
inverters
Renewable Energy
Dispatch and Control • …

Less Pollution and More


Environmental Friendly

Renewable Energy Dispatch


and Control
NARI
3.3 Demand Response
Part 03 :Advantages of the NARI

Typical Distribution Network with DER and more Power Peak Load Voltage Drop Voltage Regulation with OLTC,
Electronics SVC

Utility Company should use active control method to


realize demand response function, like,
→ Conservative Voltage Regulation
→ Distributed Battery Storage

Distribution Loss Analysis


NARI
NARI Technical
Description

Part 04
Architecture, Function, Highlights, Advantages

NARI
4.1 Smart Distribution Overall Solution
Part 04:NARI Technical Description
SCADA DMS GIS OMS DERMS
Master
Station

Dispatching
Backbone Center Substation
Network
Substation
Substation Substation

OLT xPON OLT

Access eLTE/
ONT Public Network
Network

ONU CPE

Terminal
RTU FLTU DTU TTU FICU
NARI
4.2 Advanced Distribution Management System (ADMS) Architecture Overall Solution
Part 04:NARI Technical Description
QF1 c O c QF2

IR1 IR2 IR3

110/11 kV 110/11 kV

Substation 2
Substation 1
c c O c

IR4 IR5 IR6 IR7 QF3

Self-healing Function in DA GIS Based Outage Management Mobile Workforce Management

 Fault event detection and location  Outage event detection and fault affected area location
 Affected area isolation and power  Display outage information on the map
restoration to non fault area
 Automatically send work orders and crew to the outage site
 Outage analysis and switching plan
 Outage cause analysis and restoration time estimation
 Full power restoration

NARI
4.3 Advanced Distribution Management System (ADMS) Architecture Overview
Part 04:NARI Technical Description
 Control Systems  DMZ Zone
SCADA DMS OMS DERMS IS&R WEB/ICCP Patch
Database Servers Servers Servers Servers Servers Servers /IEB NMS Updates
GPS
Firewall
Stacked Stacked
Switches IS&R Switches

Patch& Security Network


Workstations DTS Servers A/V Mant. Mant.
ICCP Firewall
FES
Servers Servers Router Stacked
Stacked Cluster Switches
Switches

Router
DA  DTS  Management Cluster
DA
Firewall Firewall GIS AMI ….

Router Router
Cluster Cluster

MPLS
SDH -VPN

Control Center

NARI
4.4 Fault Location, Isolation & Service Restoration (FLISR)
Part 04:NARI Technical Description
 Normal State

RMU RMU RMU RMU RMU RMU RMU

 Fault Occurs & Affected Area

RMU RMU RMU RMU RMU RMU RMU

 Isolate and Restore Load Transformer

RMU RMU RMU RMU RMU RMU RMU

NARI
4.5 Outage Management System (OMS) Overview
Part 04:NARI Technical Description
Improving Customer Satisfaction
With Efficiency and Interaction
8. Reply to Customers 4. Fault Location

7. Cause of Outageand
Customers GIS OMS Procedures
Repair Situation

1. Fault Step 1: Report fault (customers)


3. Fault Information
Information
Step 2: Input fault into OMS
2. Fault
Step 3: Fault analysis
Information
Call Center 5. Cause of Outage Step 4: Fault location
and the Regions Affected
4. Fault Location OMS Step 5: Affected areaanalysis Step
Step 6: Fault recovery

Step 7: Feedback fault causes and repair


3. Fault progress
Information
6. Emergency Step 8: Reply to customers
Maintenance
Status
Emergency Maintenance Distribution Master
Station NARI
4.6 GIS Overview
Part 04:NARI Technical Description

NARI
4.7 Communication Network System
Part 04:NARI Technical Description ↙ Communication Layer
 Backbone: MPLS
 Cellular
 OLT
 Optical splitter ↙ Field Area Network
 ONU  PLC Mesh
 RF Mesh
 Ad Hoc Wireless

← Interface Layer
 RTU
 DTU
 FTU

↖ Physical Layer (NOT SHOWN HERE)


 Substation: Circuit Breaker, Power Transformer…
 Feeders
Distribution Grid - Cyber Physical System  Distribution Transformer
 Capacitor Banks

NARI
4.8-1 Digital Substation Automation System Based on IEC 61850
Part 04:NARI Technical Description
IEC 61850 is an international standard defining Basic Terms:
communication protocols for intelligent electronic • MMS: Manufacturing Message Specification
devices at substations. • GOOSE: Generic Object Oriented Substation Event
• SMV: Sampled Measured Values
• ACSI: Abstract Communications Service Interface

Typical Topology of Digital Substation, NARI


Star or Ring Network Depends on Engineering,
All Schemes Supported
NARI
4.8-2 Digital Substation Automation System Based on IEC 61850
Part 04:NARI Technical Description • Main Benefits from IEC 61850
What’s the difference between MMS, GOOSE, SMV? • Easy for design, specification,
Why we need independent networks for above? configuration, setup, and
maintenance.
– High-level services enable self-
describing devices &
automatic object
• discovery
– Standardized naming conventions
with power system context
OSI 7 Layer Model vs. MMS, SMV & GOOSE
– Configuration file formats
eliminate device dependencies
and tag mapping and enables
exchange of device configuration.
• Strong functional support for substation
• communication
– Higher performance multi-cast
messaging for inter-relay
communications
IED Subtracts to a Server/Client mode • Extensible enough to support
All data was self-described with LD, LN and DO hierarchy system evolution
NARI
4.9 System Optimization: MMS + GOOSE + Conventional Analog Input
Part 04:NARI Technical Description

Full Digital – GOOSE, SMV Optimization: MMS + GOOSE + Analog Input


Conventional Type – Analog Input, Binary Input
• Add more critical intermediate to • Protection is mostly bay-oriented
protection, make more fixed delay of – Analog inputs’ quantity is limited and
trip and more complexity. Fixed
• Merging unit will be a dedicated – Cross-bay protection analog inputs
device must be installed. Increase extension is rare, busbar is typical.
the budget Busbar can use a distributed scheme
• MU is strongly related to primary to easy extended.
equipment, the expected lifetime – Using GOOSE to ease binary input
is not match with primary parts. design, engineering and
installation.
• Save the cost of merging unit which is much
higher than saved cables
– Sampling Synchronization problem
solved
– Disturbance of Optical or Weak
transduce signal is avoided.
• Conventional PT/CT’s lifetime is testified.
4.10 Up-to-Date Switchyard Installed Automation (Protection & Control)
Part 04:NARI Technical Description
• NOT relying on time synchronization
• Eliminate majority of copper wiring to better utilize resources
for the design, building, commissioning and maintenance of
power system protection and control
• Robust and simple architecture for deploying IEC 61850
process bus
• Extremely rugged hardened switchyard interface suitable for
harsh environments
• Built as an extension of Basic Module, is available for a wide
array of protection applications
• Limits exposure to cyber security threats to physical
interruption
• Improves employee safety by limiting the number of high-
energy signals in the control building
• Save up to 50% in P&C labor costs
NARI References

Part 05

NARI
5.1-1 NARI Typical References
Part 05:NARI References
Thailand, Brazil,
Philippine,Laos,Vietnam, Australia,
Greek and Sudan over 16 countries
Within these international projects,
NARI gains lots of experience and
successfully integrated with
automation substation systems of
different manufactures, including
SIEMENS, ABB, GE, CEPEL etc.

NARI
5.1-2 NARI Typical References
Part 05:NARI References

NARI
5.1-3 NARI Typical References
Part 05:NARI References

NARI
5.1-4 NARI Typical References
Part 05:NARI References

NARI
5.2 NARI Reference List in Indonesia
Part 05:NARI References

NARI
No. Contract Name Actual Date of Product
Operation
1 PT.PJPP 2*15MW project phase Two 2006SCADA
2 PT.CI 2*7MW Thermal power plant extend 2006SCADA
3 Indonesia Paiton 1 X 660 MW 2007Ash from ESP
4 Indonesia Ecogreen 1x7.5MW 2007Excitation System
5 Indonesia Perawang Project 2x36MW 2007Excitation System
6 Indonesia Perawang Extention Project 1x150MW 2007Excitation System
7 North Sulawisi wind harbour 2*115MW PLTU 2007SCADA
8 PT.NJ 2*7.5MW Thermoelectricity project 2007SCADA
9 PT CP 1*3MW power plant 2008SCADA
10 PT.EIP 1*7.5MW power plant 2008SCADA
11 PT.PPE 2*7MW power plant 2008SCADA
12 PLTG power plant 2008SCADA
13 Longwan power plant 2008SCADA
14 SIBAYAK Geothermal Power Plant Project NS2000/MGT 2008IED
15 Indonesia Muyin Power Plant 2x150MW 2008Excitation System & Ash
from ESP
16 PT.MSE 2*7.5MW power plant 2009 SCADA
17 ATAMBUA 4*7MW power plant 2009 SCADA
18 ECOGREEN 1*7.5MW Thermal Power Plant Project 2009 SCADA NARI
No. Contract Name Actual Date of Product
Operation
19 Sulawesi power plant 2010 SCADA
20 PT.IFI 1*15MW power plant engineering auxiliary equipment 2010 IED
21 PT.SJM 1*7MW power plant engineering auxiliary equipment 2010 IED
22 PT.PI 2*15MW power plant engineering auxiliary equipment 2010 IED
23 West Kalimantan 2*50MW power plant automation system 2010 SCADA
24 Thermal Power Plant in East Kalimantan Indonesia 2010 SCADA
25 Sulawisi 2*50MW PLTU 2011 SCADA
26 PLTU MALUKU(AMBON)2*15MW SCADA 2011 SCADA
27 PT.KP2*15MW power plant automation system 2011 SCADA
28 PT.TLG 2*12.5MW power plant electrical equipment 2011 SCADA
procurement
29 Indonesia Sinar Mas Asia Pulp & Paper (APP) 1x150MW 2011 Excitation System
30 Coal Fired Power Plant Project in West Sumatra Indonesia 2011 SCADA
31 2×25MW Thermal Power Plant NS2000 in East Kalimantan 2011 SCADA
Indonesia
32 PT.BA2*8MW power plant engineering auxiliary equipment 2012 IED NARI
No. Contract Name Actual Date Product
of Operation
33 PT.BAU BAU 2*7MW power plant engineering auxiliary equipment 2012 IED
34 PT.PLN KENDARI 1*10MW power plant microcomputer protection 2012 SCADA
SCADA
35 PT.PHPO 1*12MW power plant engineering auxiliary equipment 2012 IED
36 PT.WIJAYA 1*30MW power plant electric control device 2013 IED
37 PT.PHPO 1*6MW power plant automation system phase two 2013 SCADA
38 PT.EEI 2*7MW power plant automation system 2013 SCADA
39 EMBALUT 1X60MW Power Plant Expansion Project in East Kalimantan 2013 SCADA
Indonesia
40 Indonesia Sumatera Sumsel 5 Power Plant 2X150MW 2013 Ash from ESP and
Economizer
41 Indonesia Banten Power Plant 1X670MW 2013 Ash from ESP and
Economizer
42 Phosphoric acid PKG project automation system 2014 SCADA
43 PARIT BARU project microcomputer protection and related equipment 2014 IED

44 PT.PJPP 2*18MW power plant equipment 2014 SCADA


45 PARIT BARU project supplement line protection and related device 2014 IED
NARI
No. Contract Name Actual Date of Product
Operation
46 Indonesia Central Java Power Plant 2X1000MW 2014 Ash from ESP and Economizer
47 Indonesia Medan Power Plant #1, #2 2X150MW 2015 Ash from ESP and Economizer
48 Sinergy power plant thermoelectric project power plant 2016 SCADA
automation system
49 Indonesia Tanjung Jati ‘B’ Coal Fired Power Plant 2016 Fly Ash Conveying System
50 Indonesia Likupang 21 MW solar project 2017 EPC solar project
51 Indonesia Prinaggabaya 7MW solar project 2017 EPC solar project
52 Indonesia Senlong 7MW solar project 2017 EPC solar project
53 Indonesia Sengkol 7MW solar project 2017 EPC solar project
54 Indonesia JAVA 7 Coal Fire Power Plant 2X1075MW 2017 Excitation System
55 Indonesia Jatigede Hydro Electric Power 2X56MW 2018 SCADA AND SWITCHGEAR AND
Relay Protection AND Fault
Recording System
56 PLN DISTRIBUSI JAKARTA RAYA 2018 Gateway

NARI
For You For Us For the World

Copyright©2019 PT.NARI INDONESIA FOREVER. All Rights Reserved.

NARI

Potrebbero piacerti anche