Electronic Overload Relays

EOCR

®
U
NABCB
QM 030

ISO 9001 : 2008


http://www.cacindia.net
Electronic Overload Relays EOCR
CONCORD has been the pioneer of the Electronic Motor Protection technology in the Indian market with innovative and useful products for the
Industry since 1997. We design build and supply a vast array of Electronic Protection Relays and our vision is to become the best supplier for Motor
protection and Motor management for its customers nationwide.

Salient Features
Ÿ
Compact Design Ÿ
Ammeter Function Ÿ
Test Function
Ÿ
2/3 Integral Current Transformers Ÿ
Trip Indication/ Fault Diagnosis Ÿ
Suitable for use with External CT’s upto 600A
Ÿ
Multiple Protection Features Ÿ
Highly Accurate Ÿ
Ambient Insensitive
Ÿ
Wide Current Adjustment Range Ÿ
Looping Options Ÿ
Low Energy Consumption
Ÿ
Manual/ Electrical Remote Reset

D-Time (Starting delay Time)


The D-Time is the time taken by the motor before it reaches it’s normal
running current. During start the motor draws much higher levels of
current and the D-Time setting is to ensure that the EOCR does not
cause any nuiscance trippings before this set time has elapsed. After the
D-Time setting is over the relay monitors the normal running currents.

TIME
O-Time (Operating Time) D-Time O-Time Full Load Current
Normal Load
O-Time is the operating time in the event of overload. When motor
Set Current
current exceeds the desired set current value, the EOCR detects the
increase and trips the motor within the set O-Time preventing excess

TRIP
heating and long periods of overload.
CURRENT

Test Function Reset Function


The TEST function facility on the front face of the relay is provided to By pressing the RESET button or disconnecting the electrical supply
check the health status of the relay without electrically nergizing the will trip the relay immediately. Once the relay has tripped due to any
relay. On pressing the TEST button the internal relay will trip after the D- Over Load or any other fault, the relay has to be reset to start the
Time + O-Time settings have elapsed. After using this test facility , the motor again.
RESET button has to be pressed to operate the relay

TEST RESET

Looping Option

The Looping option is required in case the amount of current


measurement is desired to be more accurate and precise. The wire from
the main line when passing through the Internal EOCR CT is looped one
or more times depending upon the current range of the relay to suit the
application.

[A] 1x 2x 3x 4x 5x
-05 0,5-6 0,25-6 0,17-2 0,13-1,5 0,1-1,2

-30 2,5-30 1,25-15 0,83-10 0,62-7,5 0,5-6

-60 5-60 2,5-30 1,7-20 1,25-15 1-12

External CT Option

By using External CT’s with secondary rating of 5A the EOCR can be


used to monitor and protect motors with normal running currents of
upto 600A. This is used with an 05 Type relay with current setting range
of 0.5 - 6A. In Digital models the display current values are selectable as
desired.
EOCR SS
CONCORD
EOCR DS EOCR SSD
SOLID STATE MCU BASED DIGITAL

Protection Functions Protection Functions Protection Functions


Overcurrent O-Time Overcurrent O-Time Over current O-Time
Phase Loss O-Time Phase Loss Within 4 seconds Phase Loss Within 4 sec
Locked Rotor O-Time + D-Time Locked Rotor Within D-Time Locked Rotor 0.5 sec after D Time
Phase Reverse 0.1sec has elapsed
Features Features Features
2 Integral Current Transformer’s 3 Integral Current Transformers 2 CT based Digital Protection Relay
Electronic Shear Pin Function Independently adjustable D-Time and O-Time Current Display of Max. current in any phase
Independently Adjustable D-Time and O-Time Independent Mounting Highly accurate protection for Locked Rotor
Independent Mounting Run Monitor and Fault Diagnosis with 2 LED’s Compact Size and Ambient Insensitive
Indepebdent settings for D-Time and O-Time

Specifications Specifications Specifications


Current Setting Type Range Current Setting Type Range Current Setting 05 0.5-6A
05 0.5-6A 05 0.5-6A 30 3-30A
30 3-30A 30 3-30A 60 5-60A
60 5-60A 60 5-60A
100A and above With External CT Starting Delay Time 1-30 sec
100A and above With External CT (D-Time)
Time Setting Start(D-Time 1 - 50sec
Time Setting Start(D-Time 0.2-30sec
Trip (O-Time) 0.2-10sec Operating Time 1-10 sec
Trip (O-Time) 0.2-10sec Control Voltage Control Voltage 180-260VAC (O-Time)
Control Voltage 220 90-260VAC Contact Rating Contact Rating 1SPDT(1C) Reset Manual/Remote
440 320-480VAC Rating(R) 3A 250VAC
Normally Overcurrent Trip Definite
Contact Rating Mode 1SPDT(1C) Status
Rating(R) 3A 250VAC Energized Control Voltage 110V AC/220V AC
Status Normally Time Current Contact Rating 2SPST 3A/250V AC Resistive
Characteristic Definite Fault Diagnosis 7 Segment LED Display
Energized
Operating Mounting 35mm DIN Rail/Base
Time Current Definite
(Trip Indication 2 LED with Fault Diagnosis
Characteristic
Mounting 35mm DIN Rail/Base
Operating 2 LED
(Trip Indication)
Mounting 35mm DIN Rail/Base
Wiring Diagram Wiring Diagram
Wiring Diagram L1 L2 L3 L1 L2 L3
L1 L2 L3
Tr. Fuse Tr.
Tr.
OFF/RESET
OFF
(RESET)
OFF/RESET MC
ON
MC MC ON
MC MC

MC ON MC
EOCR DS3
L1 L2 95 96 97 98

N 98
97
96
R 95
A2
L1 L2 95 96 98

A1
EOCR SS

M EOCR SSD N TYPE


M

Overall DImensions
M Overall DImensions 58 62.2
51 10
6-M3.5 7 10
Overall Dimesnions
19.5

12
10
CONCORD
16

12

8888
81
69

50.8
65

46
54
44

8.4 58 39
5 - M3.5 6-M3.5
DIN RAIL TYPE
54 77.2
CONCORD
Wiring Diagram
EOCR 3DE / 3EZ
L1 L2 L3 L1 L2 L3
DIGITAL
FUSE * Tr. FUSE Tr.

MC
OFF MC OFF

RESET
RESET
MC MC MC
ON
MC ON
ALERT
TRIP

A1 A2 Z1 Z2 97 98 5758
MC R MC Aux R G Y
G

EOCR 3EZ
A1 A2 95 96 97 98 0708
Stop Run Trip/GR

EOCR 3DE
A1 96 98 08 STOP Aux
OL/ AL/ A1 Z1 98 58
UL UL OL/UL GR
EOCR
EOCR Aux

~
-3DE
Z1(k) -3EZ

A2 95 97 07 Z2(k) A2 Z2 97 57

Protection Functions M EOCR 3DE M EOCR 3EZ


3DE 3EZ
Protection
Trip Time Trip Time
Overcurren O-Time O-Time Overall DImensions
Undercurrent 0.5-30 sec 0.5-30 sec 10
Phase Loss 3 sec 3 sec
Phase Unbalance 8 sec 8 sec

16

15
Phase Reverse 0.1-0.3 sec 0.1-0.3 sec
Locked Rotor D-Time D-Time
Ground Fault NA 0.05-10 sec

7.5
71
59
53
Features
MCU Based Design
3 Integral Current Transformers
Multiple Protection Features
Digital Ammeter and Fault Diagnosis 70
DIN RAIL TYPE
Wide Current Adjustment range
User selectable Time Current curves - Definite/Inverse
Manual/Remote reset Trip Characteristic
Ambient Insensitive TIME (sec)
Alert Function before trip 10000
HOT
TIME ( sec)
COLD
Adjustable

Specifications 1000

3DE 3EZ
Current Setting 05/60A 05/60A
100
Above 60A With Suitable External CT
Ground Fault setting NA A:0.02-3A, B:0.2-10A 30
30
Alert Setting 5-100%/OFF NA 10 20
30
20

Start Delay Tim 10 10


5
5
(D-Time) 1-200 sec
1 1
Trip Delay Time INV 1-30 sec 0.2
(O-Time) DEF 0.2-30 sec 0 1 2 3 4 5 6
Current
Control Voltage 110VAC/220VAC 0.1
1 2 4 6 8 10 Multiples of Current Setting
Contact Rating 2 SPST 3A/250V Resistive CURRENT
Multiples of Current Setting
Trip Time INV/DEF- Refer to Graph Inverse Type - EOCR 3DE/EZ Definite Type - EOCR SS/SSD/DS
Characteristic
Fault Diagnosis 7 segment LED Display
Mounting 35mm DIN Rail/Base *We reserve the right to change specification without notice

For More details/information, please contact:


CONCORD AUTOMATION & CONTROLS
Available in your area with:
G 43, DLF Industrial Estate, 1 Faridabad
121003 Haryana (INDIA)
Phone : 0129 2278256, 2273860
Mobile : +91 9810659379
Fax : 0129 2278350
Email : info@cacindia.net
Website : http://www.cacindia.net

Potrebbero piacerti anche