Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Tank Data
Computed Values
A-1
FIXED ROOF TANK CALCULATION (AP-42: Chapter 7 Method)
Tank Data
Computed Values
A-1
FUGITIVE HYDROCARBON CALCULATIONS - CARB/KVB METHOD
Page 1 of 2
ADMINISTRATIVE INFORMATION
Attachment: A-3
Company: ABC Oil, Inc. Version:
Facility: Leroy Pine Date:
Processed by: JJM
Date: 7/16/2019
Path & File Name:
Model #1: Number of wells on lease is less than 10 and the GOR is less than 500.
Model #2: Number of wells on lease is between 10 and 50 and the GOR is less than 500.
Model #3: Number of wells on lease is greater than 50 and the GOR is less than 500.
Model #4: Number of wells on lease is less than 10 and the GOR is greater than 500.
Model #5: Number of wells on lease is between 10 and 50 and the GOR is greater than 500.
Model #6: Number of wells on lease is greater than 50 and the GOR is greater than 500.
Efficiency Factor: (70% for well cellars, 0% for uncovered WW tanks, sumps and pits)
Unit Type/Emissions Factor
Heavy Oil Service Light Oil Service
Primary 0.0941 0.138 (lb ROC/ft2-day)
Secondary 0.0126 0.018 (lb ROC/ft2-day)
Tertiary 0.0058 0.0087 (lb ROC/ft2-day)
0.00 0.00
Covered Wastewater Tanks Equipped with Vapor Recovery
Efficiency Factor: varies (85% for cover, 95% for VRS, 0% for open top)
Emissions Factor: 560 (lb ROC/MM Gal)
fhc-kvb5.xls
24-Oct-00
METHOD
Tertiary
0.00
0.00
Tertiary
0.00
0.00
Tertiary
0.00
Total
lb/day
0.0
LOADING RACK EMISSION CALCULATION (ver 3.0)
Hourly
THLH = (R)(42 gal/bbl)(LL/1000) = 0.19 lbs/hr
Daily
THLD = (THLH)(HLPD) = 1.80 lbs/day
Annual
THLA = (HLPY)((THLH)(1/2000) = 0.13 TPY
Hourly
THLHC = (THLH)(1-eff) = 0.01 lbs/hr
Daily
THLDC = (THLD)(1-eff) = 0.09 lbs/day
Annual
THLAC = (THLA)(1-eff) = 0.01 TPY
Notes:
DATA
Emissions
NOx ROC SOx CO PM PM10
lb/hour 1.19 1.51 0.90 6.48 0.35 0.35
lb/day 28.56 36.16 21.55 155.40 8.40 8.40
ton/year 5.21 6.60 3.93 28.36 1.533 1.533
FUGITIVE ROC EMISSIONS CALCULATION
ADMINISTRATIVE INFORMATION
Attachment: A-6
Company: ABC Oil, Inc.
Facility: North
Processed by: JJM
Date: February 2014
Path & File Name:
Oil Service
Valves - Acc/Inacc 125 0.0041 0.56
Valves - Unsafe 0.0041 0.56
Valves - E-500 0.0041 0.56
Valves - E-100 0.0041 0.56
Flanges - Acc/Inacc 1,000 0.0020 0.56
Flanges - Unsafe 0.0020 0.56
Flanges - E-500 0.0020 0.56
Flanges - E-100 0.0020 0.56
Pump Seals - Single 16 0.0039 0.56
Pump Seals - E-500 0.0039 0.56
Pump Seals - E-100 0.0039 0.56
PSV - To Atm 0.2670 0.56
PSV - To VRS 0.2670 0.56
PSV - E-500 0.2670 0.56
PSV - E-100 0.2670 0.56
Sub Total 1,141
Total 1,747
Notes:
1. Source:
2. APCD P&P # 6100.060.1998.
3. APCD P&P # 6100.061.1998
4. A 80% efficiency is assigned to fugitive components Rule 331 implementation.
ROC EMISSIONS CALCULATION
Table 2.
Facility Potential to Emit
NOx ROC CO SOx PM PM10
Towne Exploration- Luton Lease
lbs/day 30.28 52.55 169.58 24.00 8.76 8.76
tons/year 5.53 9.59 30.95 4.38 1.60 1.60
Table 3.
Net Emissions Increase
NOx ROC CO SOx PM PM10
Towne Exploration- Luton Lease
lbs/day 30.28 52.55 21.80 11.18 1.27 8.76
tons/year 5.53 9.59 3.98 2.04 0.23 1.60
Table 4.
Exempt Emissions
NOx ROC CO SOx PM PM10
Towne Exploration- Luton Lease
lbs/day 0.00 0.00 0.00 0.00 0.00 0.00
tons/year 0.00 0.00 0.00 0.00 0.00 0.00