Ultimate strength analysis girder-cross section: PIER2 , Variante: CS1

Action forces and capacity factor


No. Analysis-Parameters N My Mz Capacity factor Remarks
[kN] [kNm] [kNm] [-]
1 C:TTGHCD -5936.0 6207.0 1997.0 0.305

Analysis-Parameters "TTGHCD", Code: Eurocode ENV/EN


A.Typ --Diagram Strain Limits Adm.Stress Resistance factors Various parameters
Concrete PT.Steel cu.c cu.b su s.adm c s p a  
[‰] [‰] [‰] [N/mm²] [-] [-] [-] [-] [-] [-]
C 2/0 1 -2.0 -3.0 20.0 1.00 1.00 1.00 1.00 45.00 0

Extreme stresses and strain


Name Class yq zq  / 
[m] [m] [‰] [N/mm²] [-]
CS5 C20/25 6.8457 0.8115 -2.9 -17.0 1.18
CS5 C20/25 0.1257 0.0115 20.9 0 1.18
PR38 S200 6.8332 0.7815 -2.0 -200.0 1.00
PR10 S200 0.1381 0.0415 20.0 200.0 1.00

Stresses and strain during the last iterations step = Ultimate state
Internal forces Strain and Curvature Stiffness Values
N My Mz x y z N/x My/y Mz/z
[kN] [kNm] [kNm] [‰] [km-1] [km-1] [kN] [kNm²] [kNm²]
-1808.4 1890.5 608.3 9.0 29.2 0.1 2.013E+5 64742.80 9.51E+6