Operation Instructions Operation Instructions

1. Reading Cards
Position a card in front of the blue reading head within 5 Press 1 time, display current time: , e.g.:
cm, then hold down the button for approximately 1
second. 4 flashes of the red indicator light accompanied
by 1 “beep” sound means that a reading has been Press 2 times,display data:
made. The LCD screen shows the last 4 digital code of Press 3, 4, 5 times, display hex card number in three
this card. (see Fig 1)
sections, e.g.: , ,

LCD display Where: H represents 16 hexadecimal, 210015B386


10-digit card number.
Botton
EMID Card
3. Turning Off
Automatically turns off if no cards are read or if the
LED button is not pressed for 10 seconds.

4. Data Upload
Connect the communication station to the PC USB port,
Fig 1 Reading Cards and place the probe reader in its indentation.
Running inspection management software , clicking
2.Turning On "Read Probe" operation button, and the software system
Press the button to turn on the reader. It may display the will automatically read inspection probe number,
current time. when GS-6000E doesn't read card; the LCD automatically calibrate the probe’s internal clock time,
screen displays the current time and the previous card upload, save and process data, etc.
reading data number in sequence.

Operation Instructions Operation Instructions

Data Sheet
Card Format EMID
4MBit Flash RAM,
Memory
30,000Records
Reading Range 0~5cm
Power Capacity >500,000 Readings
Battery 3.6V lithium battery
Working Temp. -40℃~70℃
Working Hum. 0~95℅
Fig 2 Data Upload Dimensions 147×42×26mm
Weight 200g
When connecting the communication station with PC,
The buzzer will ring long, and the red indicator at top Status Indications
right corner will be lit long, meaning the communication 1. 1 Beep With 4 Flashes: Reading is successful.
station work right. 2. 4 Beeps With 4 Flashes and the LCD shows

5.First-Time Usage :
Before reading signal cards, should connect the probe The reader’s internal clock is erroneous and should be
with the PC first, and start the software to calibrate the calibrated with the PC before further reading card.
reader’s internal clock. Wait until it automatically shuts
down before performing readings. 3. Continuous Flashes: The batter is low and needs to be
changed.
Operation Instructions

4. After card reading, buzzer produces 1long beep 、 1


short beep and indicator flashes 2 times, it means the
Guard Tour Reader
reader’s storage is full, the LCD shows during
card reading, the data needs to be uploaded.
Usage Manual
Trouble shooting (GS-6000E)

Failed to Scan Signal Cards


Solution 1: After communicating with the PC, wait for
the probe shutting down before starting to scan signal
cards again.
Solution 2: The reader’s memory may be full. Connect
with a PC to upload data before scanning more signal
cards.
Failed to Communicate with PC:
Solution 1: Make sure that the PC software is operating
properly, Select " GS-6000D,E,F " among the inspection
“probe type”, click "Read Probe" operation button.
Solution 2: Make sure that the GS-6000T wireless
communication station is properly connected to the PC,
and that it has been found by the PC software, select port QUALITY SOURCE SPECIAL
(it's COM3 under most scenarios, or view CP2101
converted port number in the device administrator).