Cables and Cordsets for

Extreme Applications MARINE CABLE

• ABS Approved

• Certified per IEEE-45

• UL listed for Marine


Applications to STD UL 1309

• Meets IEC 332-3 Category A


Flame Test

• CSA listed to C22.2 No. 245

• Jacket Material Provides


Impact Protection to
-50˚C (-58˚F)

• Available in Multiple
Configurations

www.turck.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

extremelife™ cables are heavy duty for extreme temperature environments. These cables provide excellent resistance to
extreme cold temperatures and oilfield drilling muds. TURCK offers multiple single and twisted pair conductor options.
extremelife cables are available in two jacket types, extremelife-25 and extremelife-55. The following characteristics are
specific to each cable.

Characteristics extremelife-25 extremelife-55


Cable Gage Range 16 to 22
UL Rating UL1309
CSA Rating CSA 22.2 No. 245
ABS Approval No. 03-HS400763-PDA
IEEE Approvals IEEE 45-1998 and IEEE 1580-2001
Flexible Stranding Yes
Standard Insulation T75 and T90 UL and CSA, T75 IEEE
XLPE Insulation 110X for increased electrical properties required for network applications
Flame Retardancy IEEE 1202/FT4 and IEC 332-3 Category A
Cold Bend Pass Temperature -40°C (-40°F) -55°C (-67°F)
Cold Impact Pass Temperature Good -50°C (-58°F)
Cut through and Abrasion Resistance Good Excellent
Moisture and Oil Resistance Excellent
Installation Handling Good
Oilfield Drilling Mud Resistance Excellent
Braided Armor Available with or without
Sunlight Resistance Yes

1 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

extremelife™ cables have been extensively tested in various drilling muds/fluids.


Samples of five different drilling fluids were used to evaluate how extremelife cables
handle harsh environments. Cable samples were placed in the muds and put in a
test oven at +65.6°C (+150°F). Shrink/swell as well as tensile strength/elongation
were monitored throughout a 28 day aging test.

The extremelife cables, with their exclusive jacket materials, were compared with the
industry standard neoprene cables. All tested cables passed the tensile strength and
elongation tests. The extremelife cables proved to be much more stable in size
through the tests when compared to the neoprene jacketed cables.

Drilling Mud Types Used:


• Water based
• Synthetic based (two types)
• Diesel based
• Mineral oil based

extremelife Cables:
• Standard cables are stocked for quick delivery, and custom designs ship within 6 to 10 weeks.
• Multiple designs and custom configurations can be built using 16 to 22 AWG wires and up to 42
single conductors or 48 twisted pairs.
• Bronze armor styles combined with stable tinned-copper armor.
• Cost effective cables, since extremelife can be made with 22 AWG conductors and
tinned-copper armor.
• Assorted conductor sizes and insulation materials allow usage in network applications.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 2

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

Hazardous Locations
TURCK process wiring systems provide flexibility and functionality for use in hazardous locations. When installed correctly,
the system is FM approved for use in Class 1, Divisions 1 and 2 per TURCK drawing QCF-00147, found at
www.TURCK.com/fmcd.

Class 1, Division 2 - Quick Disconnect Basics

Hazardous Nonhazardous
minifast Location Location
Device Entry
Receptacle
lokfast™ guards are used on
all minifast ® connections in
minifast
hazardous locations. The
Cordsets molded construction of the
integral home-run connector
and the gas/vapor tight
continuous sheath of cable
Nonincendive meet the requirements of the
Equipment NEC, Article 501-5(E)(2) for
minifast
lokfast Guard cable seals in Division 2.

Boundary Cable
Seal Not Required

Class 1, Division 1 - Explosion Proof Method

Explosion Proof Cable Gland


The explosion proof method can be used in Class 1, Division 1
locations by connecting an explosion proof cable gland to the
Armored
extremelife Cable transmitter. Armored extremelife™ marine shipboard cable, with
an overall impervious sheath over the armor, is the recommended
wiring method for this environment.

Class 1, Division 1 - Intrinsically Safe Circuits

Hazardous Location Nonhazardous


Location Instrisically safe circuits do not
Boundary Cable
Seal Not Required require lokfast guards on quick
Intrinsically
disconnects. Boundary seals are not
Intrinsically
Safe Apparatus Safe required as the molded construction
Barriers of the home-run connector and the
gas/vapor tight continous sheath of
the cable meet the requirements of
Molded Connector the NEC, Article 501-5(C) for cable
Provides gas/vapor seal. seals in Class 1, Divisions 1 and 2.

3 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

Cable is only part of the story. TURCK has been building connectivity products
for over 15 years. TURCK connectors are approved by DNV and ABS for use in
marine shipboard environments. TURCK also provides connectivity products
for hazardous areas including our exclusive lokfast™, which changes any
TURCK connector into a tool-only removable connection. For wire
consolidation, TURCK has an entire line of junction boxes. From off-the-shelf
junctions for 4-20 mA transmitters to custom boxes for any application, TURCK
reduces costs by making wiring faster, easier and more reliable.

Table of Contents

Introduction, extremelife™ Overview . . . . . . . . . . . . . . . . 1-3

minifast ® Control Cordsets . . . . . . . . . . . . . . . . . . . 5-6

minifast Control Cordset Part Number Key, Extensions . . . . . . . . . . . 6

minifast Control Receptacles, 1/2-14NPT, 3/4-14NPT, and M20 Threads . . . . . 7-12

minifast Network Cordsets . . . . . . . . . . . . . . . . . . . . 13

minifast Network Cordset Part Number Key, Extensions . . . . . . . . . . 14

minifast Network Receptacles, 1/2-14NPT, 3/4-14NPT, and M20 Threads . . . . 15-17

extremelife Cable Selection Guide . . . . . . . . . . . . . . . . . 18-20

minifast Field Wireables . . . . . . . . . . . . . . . . . . . . 21-22

minifast lokfast™ Guards . . . . . . . . . . . . . . . . . . . . 23

minifast Closure Caps . . . . . . . . . . . . . . . . . . . . . 24-26

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 4

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

4, 5, 7 and 8-Wire minifast ® Control Cordsets

• Female Connectors
• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Cable Features Pinouts


PVC Black
3x18 AWG, 1 STP with GND
extremelife™-25
Foil/Drain
P-RKV 40-180-*M UL 1309 approved
90°C, 300 V, 9 A
2-wire Analog
8.4 mm OD
Cable #RF51180-*M†
PVC Black, Braided Armor
extremelife-25
3x18 AWG, 1 STP with GND 1. BU
Braided Armor
Foil/Drain 2. BN
P-RKV .. P-RKV 40-181-*M Cable
90°C, 300 V, 9 A 3. Drain
UL 1309 approved
12.5 mm OD 4. GN/YE
2-wire Analog
Cable #RF51181-*M†
TPE Black
3x18 AWG, 1 STP with GND
extremelife-55
Foil/Drain
P-RKV 40-188-*M UL 1309 approved
90°C, 300 V, 9 A
2-wire Analog
8.4 mm OD
Cable #RF51188-*M†

PVC Blue extremelife-25 1. BK


5x18 AWG, Foil/Drain UL 1309 approved 2. BU
P-RKV 56-964-*M 90°C, 300 V, 9 A 5-wire with 3. GN/YE
10.4 mm OD Foil/Drain 4. BN
Cable #RF50964-*M† (not connected) 5. WH

PVC Black 1. BU
5x18 AWG, 2 STP with GND 2. BN
extremelife-25 3. Drain
Foil/Drain
P-RKV 70-182-*M UL 1309 approved 4. WH
90°C, 300 V, 9 A
2-wire Analog x 2 5. BK
10.4 mm OD
P-RKV .. 6. Drain
Cable #RF51182-*M† 7. GN/YE
PVC Blue, Braided Armor
extremelife-25
8x18 AWG, 4 STP
Braided Armor
Foil/Drain
P-RKV 80-073-*M Cable 1. BK
90°C, 300 V, 9 A
UL 1309 approved 2. WH
17.8 mm OD 3. BU
2-wire Analog x 4
Cable #RF51073-*M† 4. RD
TPE Black 5. YE
8x18 AWG, 4 STP 6. BN
extremelife-55 7. GY
Foil/Drain
P-RKV 80-158-*M UL 1309 approved 8. GN
90°C, 300 V, 9 A
2-wire Analog x 4
15.1 mm OD
Cable #RF51158-*M†

* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.
For male connectors: change part number (P-RKV... to P-RSV). See page 6 for extensions.
Standard coupling nut material is 316 stainless steel "P-RK(S)V .."; "P-RK(S)M .." indicates nickel plated brass.

See pages 19-20 for reelfast ® bulk cable information and extremelife Cable Selection Guide.

5 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

9-Wire minifast ® Control Cordsets

Housing Part Number Cable Features Pinout


PVC Black
9x18 AWG, 4 STP with GND
extremelife™-25 1. WH/BK
Foil/Drain
P-RKV .. P-RKV 100-183-*M UL 1309 approved 2. BK/WH
90°C, 300 V, 7 A
2-wire Analog x 4 3. WH/GN
13.2 mm OD 4. GN/WH
Cable #RF51183-*M† 5. WH/RD
TPE Black 6. RD/WH
9x18 AWG, 4 STP with GND 7. N/C
extremelife-55 8. GN/YE
Foil/Drain
P-RKV 100-189-*M UL 1309 approved 9. WH/OG
90°C, 300 V, 7 A
2-wire Analog x 4 10. OG/WH
15.1 mm OD
Cable #RF51189-*M†

* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.
For male connectors: change part number (P-RKV... to P-RSV). See below for extensions.
Standard coupling nut material is 316 stainless steel "P-RK(S)V .."; "P-RK(S)M .." indicates nickel plated brass.

See pages 19-20 for reelfast ® bulk cable information and extremelife Cable Selection Guide.

minifast Extension Cordset Part Number Key - Control Cable


Part Number Keys are to assist in IDENTIFICATION ONLY. Consult Factory for catalog items not identified.

R S V R K V 40-180 - 4M S..

minifast
R = Straight /S = Consult Factory, Special
W = Right Angle /CS = Consult Factory, Special
/SI599 = Closure caps assembled on cordsets
Gender
Length in Meters
K = Female Connector, Female Threads
S = Male Connector, Male Threads
Y = Male Connector, Female Threads
Number of Wires / AWG / Conductor Colors
Coupling Nut Material
40-180 3/18 AWG BN, BU, GN/YE
(Blank) = Nylon 40-181 3/18 AWG BN, BU, GN/YE
M = Nickel Plated Brass 40-188 3/18 AWG BN, BU, GN/YE
V = 316 Stainless Steel 56-964 5/18 AWG BK, BU, GN/YE, BN, WH
70-182 5/18 AWG BU,BN, WH, BK, GN/YE
80-073 8/18 AWG BK, WH, BU, RD, YE, BN, GY, GN
Insertion Point of Extension Cable 2nd Prefix* 80-158 8/18 AWG BK, WH, BU, RD, YE, BN, GY, GN
* Male Connector Listed 1st, Female Connector 2nd 100-183 9/18 AWG WH/BK, BK/WH, WH/GN, GN/WH, WH/RD,
Example: RSV RKV 40-180-4M RD/WH, N/C, GN/YE, WH/OG, OG/WH
100-189 9/18 AWG WH/BK, BK/WH, WH/GN, GN/WH, WH/RD,
RD/WH, N/C, GN/YE, WH/OG, OG/WH
Extension Examples:

R S V R K V 40-180 - 4M W S V R K V 40-180 - 4M

R S V W K V 40-180 - 4M W S V W K V 40-180 - 4M

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 6

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

4 and 5-Wire minifast ® Control Receptacles, Front Mount, 1/2-14NPT Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male
P-RSFV 40-*/14.5/NPT

UL, CSA 1. BU
P-RSFV .. 3x18 AWG 2. BN
105°C 3. N/C Female
600 V, 9 A 4. GN/YE

P-RKFV 40-*/14.5/NPT

1/2-14NPT
Threads
P-RKFV .. Male

P-RSFV 56-*/14.5/NPT

UL, CSA 1. BK
5x18 AWG 2. BU
3. GN/YE Female
105°C
4. BN
600 V, 9 A
5. WH

P-RKFV 56-*/14.5/NPT

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
1/2-14NPT Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

7 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

7, 8 and 10-Wire minifast ® Control Receptacles, Front Mount, 1/2-14NPT Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male

P-RSFV 70-*0.5/14.5/NPT
1. BU
UL, CSA 2. BN
P-RSFV .. 7x18 AWG 3. GY
4. WH Female
105°C
5. BK
600 V, 8 A
6. GY
7. GN/YE
P-RKFV 70-*0.5/14.5/NPT

P-RKFV ..
Male

P-RSFV 80-*0.3/14.5/NPT
1. BK
2. WH
UL, CSA 3. BU
8x18 AWG 4. RD
105°C 1/2-14NPT 5. YE Female
600 V, 8 A Threads 6. BN
7. GY
8. GN
P-RKFV 80-*0.3/14.5/NPT

P-RSFV .. Male

P-RSFV 100-*0.3/14.5/NPT 1. WH/BK


2. BK/WH
3. WH/GN
UL, CSA 4. GN/WH
10x18 AWG 5. WH/RD
P-RKFV .. 105°C 6. RD/WH Female
600 V, 8 A 7. GY
8. GN/YE
9. WH/OG
P-RKFV 100-*0.3/14.5/NPT 10. OG/WH

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
1/2-14NPT Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 8

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

4, 5 and 7-Wire minifast ® Control Receptacles, Front Mount, 3/4-14NPT Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male
P-RSFV 40-*/14.75/NPT
P-RSFV ..
UL, CSA 1. BU
3x18 AWG 2. BN
105°C 3. N/C
600 V, 9 A 4. GN/YE Female

P-RKFV 40-*/14.75/NPT

P-RKFV ..

Male

P-RSFV 56-*/14.75/NPT
1. BK
UL, CSA 2. BU
5x18 AWG 3. GN/YE
105°C 3/4-14NPT 4. BN Female
600 V, 9 A Threads 5. WH

P-RKFV 56-*/14.75/NPT

P-RSFV ..
Male

P-RSFV 70-*/14.75/NPT

1. BU
UL, CSA 2. BN
7x18 AWG 3. GY
4. WH Female
P-RKFV .. 105°C
5. BK
600 V, 8 A
6. GY
7. GN/YE
P-RKFV 70-*/14.75/NPT

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
3/4-14NPT Thread receptacles recommend 1-1/16" (27.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

9 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

4-Wire minifast ® Explosion Proof Feed Through Receptacle, 1/2-14NPT Thread

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection
FM approved as an explosion proof feed-thru
when installed per TURCK Control drawing.
QCF-00147 (www.turck.com/fmcd/) using
specified accessory equipment.

Housing Part Number Lead Specs Features Pinouts

Male
P-RSFV .. P-RSFV 40D EX-*/14.5/NPT

Explosion
UL, CSA 1. BU
Proof
4x18 AWG 2. BN
Receptacle,
105°C 3. GY
1/2-14NPT Female
600 V, 9 A 4. GN/YE
Threads

P-RKFV 40D EX-*/14.5/NPT


Consult factory for Availability

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
1/2-14NPT Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

4 and 5-Wire minifast ® Control Receptacles, Front Mount, M20 Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male
P-RSFV 40-*/M20

UL, CSA 1. BU
P-RSFV .. 3x18 AWG 2. BN
105°C 3. N/C
Female
600 V, 9 A 4. GN/YE

P-RKFV 40-*/M20

M20x1.5
Threads
P-RKFV .. Male

P-RSFV 56-*/M20

UL, CSA 1. BK
5x18 AWG 2. BU
3. GN/YE
105°C Female
4. BN
600 V, 9 A
5. WH

P-RKFV 56-*/M20

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
M20 Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

11 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

7, 8 and 10-Wire minifast ® Control Receptacles, Front Mount, M20 Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male

P-RSFV 70-*/M20
1. BU
UL, CSA 2. BN
7x18 AWG 3. GY
P-RSFV .. 4. WH
105°C Female
5. BK
600 V, 8 A
6. GY
7. GN/YE
P-RKFV 70-*/M20

Male
P-RKFV ..

P-RSFV 80-*/M20
1. BK
2. WH
UL, CSA 3. BU
8x18 AWG 4. RD
105°C M20x1.5 5. YE Female
600 V, 8 A Threads 6. BN
7. GY
8. GN
P-RKFV 80-*/M20

Male

P-RSFV .. P-RSFV 100-*/M20 1. WH/BK


2. BK/WH
3. WH/GN
UL, CSA 4. GN/WH
10x18 AWG 5. WH/RD
105°C 6. RD/WH
600 V, 8 A 7. GY Female
8. GN/YE
P-RKFV 100-*/M20 9. WH/OG
10. OG/WH
Consult factory for Availability

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
M20 Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."P-RS(K)FV.."; "P-RS(K)F.." indicates nickel plated cast zinc.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 12

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

2, 4 and 5-Wire minifast ® Network Cordsets

• Female Connectors
• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

• 300 V, 9 A

Housing Part Number Cable Features Pinouts

RKV .. Type 5728, TPE Black


2x16 AWG, PVC, Power extremelife™-55 1. Drain
2x18 AWG, XLPE, Data UL 1309 approved 2. RD (+ Voltage)
RKV 5728-*M Foil/Drain Braid Braided Shield 3. BK (- Voltage)
90°C 4. WH (CAN-H)
13.5 mm OD 5. BU (CAN-L)
Cable #RB51107-*M†

Type 4910, TPE Black


2x18 AWG, XLPE, Data extremelife-55
18 AWG, Device GND UL 1309 approved
RKV .. RKV 4910-*M Foil/Drain Foil Shield
90°C
8.9 mm OD 1. BU (- Voltage)
FOUNDATION™ fieldbus
Cable #RB51047-*M† 2. BN (+ Voltage)
Type 4911, TPE Black 3. Drain
Braided Armor extremelife-55 4. GN/YE (Ground)
2x18 AWG, XLPE, Data Braided Armor Cable
18 AWG, Device GND UL 1309 approved
RKV 4911-*M Foil/Drain
90°C
FOUNDATION™ fieldbus
13 mm OD
Cable #RB51048-*M†

RKV ..
Type 258, TPE Yellow
Braided Armor 1. BN (+ Voltage)
extremelife-55
2x16 AWG, Data 2. N/C
RKV 258-*M Braided Armor Cable
90°C 3. BU (- Voltage)
UL 1309 approved
12.7 mm OD 4. N/C
Cable #RB51246-*M†

* Length in meters. Standard cable lengths are 0.3, 0.5, 1.0, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0, 8.0, 10, 15....50 meters. Consult factory for other lengths.
For male connectors: change part number (RKV... to RSV). See page 14 for extensions.
Standard coupling nut material is 316 stainless steel "RK(S)V .."; "RK(S)M .." indicates nickel plated brass.

See pages 19-20 for reelfast ® bulk cable information and extremelife Cable Selection Guide.

13 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

minifast ® Extension Cordset Part Number Key - Network Cable


Part Number Keys are to assist in IDENTIFICATION ONLY. Consult Factory for catalog items not identified.

R S V R K V 5728 - 4M /S..

minifast
R = Straight /S = Consult Factory, Special
W = Right Angle /CS = Consult Factory, Special
/SI599 = Closure caps assembled on cordsets
Gender
Length in Meters
K = Female Connector, Female Threads
S = Male Connector, Male Threads
Y = Male Connector, Female Threads
Number of Wires / AWG / Conductor Colors
5728 2/16 2/18 AWG RD, BK, WH, BU
Coupling Nut Material 4910 3/18 AWG BU, BN, GN/YE
(Blank) = Nylon 4911 3/18 AWG BU, BN, GN/YE
M = Nickel Plated Brass 258 2/16 AWG BN, BU
V = Stainless Steel

Insertion Point of Extension Cable 2nd Prefix*


* Male Connector Listed 1st, Female Connector 2nd
Example: RSV RKV 5728-2M

Extension Examples:

R S V R K V 5728 - 4M W S V R K V 5728 - 4M

R S V W K V 5728 - 4M W S V W K V 5728 - 4M

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 14

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

2, 4 and 5-Wire minifast ® Network Receptacles, Front Mount, 1/2-14NPT Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male

RSFV 57-*M/14.5

RSFV .. UL, CSA 1. GY


5x22 AWG 2. RD (+ Voltage)
3. BK (- Voltage)
105°C
4. WH (CAN_H) Female
600 V, 9 A
5. BU (CAN_L)

RKFV 57-*M/14.5

1/2-14NPT
RKFV .. Threads
RSFV 49-*M/14.5
UL, CSA 1. BU (- Voltage) Male
FOUNDATION™ fieldbus 4x18 AWG 2. BN (+ Voltage)
3. GY (Drain -
105°C
RKFV only)
600 V, 9 A
4. GN/YE (Ground)
RKFV 49-*M/14.5
FOUNDATION™ fieldbus

Female

RSFV 25-*M/14.5
UL, CSA 1. BN (+ Voltage)
2x18 AWG 2. N/C
105°C 3. BU (- Voltage)
600 V, 9 A 4. N/C
RKFV 25-*M/14.5

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
1/2-14NPT Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."RS(K)FV.."; "RS(K)F.." indicates nickel plated cast zinc.

15 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

2, 4 and 5-Wire minifast ® Network Receptacles, Front Mount, 3/4-14NPT Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male

RSFV 57-*M/14.75

UL, CSA 1. GY
5x22 AWG 2. RD (+ Voltage)
RSFV ..
3. BK (- Voltage) Female
105°C
4. WH (CAN_H)
600 V, 9 A
5. BU (CAN_L)

RKFV 57-*M/14.75

3/4-14NPT
RSFV 49-*M/14.75 Threads
RKFV .. UL, CSA 1. BU (- Voltage) Male
FOUNDATION™ fieldbus 4x18 AWG 2. BN (+ Voltage)
3. GY (Drain -
105°C
RKFV only)
600 V, 9 A
4. GN/YE (Ground)
RKFV 49-*M/14.75
FOUNDATION™ fieldbus

Female

RSFV 25-*M/14.75
UL, CSA 1. BN (+ Voltage)
2x18 AWG 2. N/C
105°C 3. BU (- Voltage)
600 V, 9 A 4. N/C
RKFV 25-*M/14.75

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
3/4-14NPT Thread receptacles recommend 1-1/16" (27.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."RS(K)FV.."; "RS(K)F.." indicates nickel plated cast zinc.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 16

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

2, 4 and 5-Wire minifast ® Network Receptacles, Front Mount, M20 Threads

• Male and Female Receptacles


• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Lead Specs Features Pinouts

Male

RSFV 57-*M/M20

UL, CSA 1. GY
RSFV .. 5x22 AWG 2. RD (+ Voltage)
3. BK (- Voltage) Female
105°C
4. WH (CAN_H)
600 V, 9 A
5. BU (CAN_L)

RKFV 57-*M/M20

M20x1.5
RKFV .. RSFV 49-*M/M20 Threads
UL, CSA 1. BU (- Voltage)
Male
FOUNDATION™ fieldbus 4x18 AWG 2. BN (+ Voltage)
105°C 3. GY (Drain - RKFV only)
600 V, 9 A 4. GN/YE (Ground)
RKFV 49-*M/M20
FOUNDATION™ fieldbus
Female

RSFV 25-*M/M20
UL, CSA 1. BN (+ Voltage)
2x18 AWG 2. N/C
105°C 3. BU (- Voltage)
600 V, 9 A 4. N/C
RKFV 25-*M/M20

* Length in meters. Standard lead length is 0.3 meters. Consult factory for other lengths.
M20 Thread receptacles recommend 13/16" (21.0 mm) hole for panel mounting.
Standard housing material is 316 stainless steel.."RS(K)FV.."; "RS(K)F.." indicates nickel plated cast zinc.

17 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 18

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

Control and Network extremelife™ Cable Selection Guide

• UL Marine 1309 Approved • ABS Approved

Diagram A Diagram B
JACKET FOIL SHIELD BRAIDED ARMOR*
JACKET
FOIL SHIELD
DRAIN WIRE DRAIN WIRE
BROWN
BROWN
BLUE
BLUE
YELLOW/GREEN
YELLOW/GREEN
DEVICE GROUND
INNER JACKET
OVERALL FOIL SHIELD
*AVAILABLE ON SOME CABLE TYPES

Diagram C Diagram D
JACKET
FOIL SHIELD
JACKET FOIL SHIELD

BROWN DRAIN WIRE


WHITE
GREEN/YELLOW {UpSeetopage4 STP
20 for
DRAIN WIRE conductor colors.
BLACK
BLUE DEVICE GROUND
OVERALL FOIL SHIELD

Diagram E Diagram F
BRAIDED ARMOR BRAIDED ARMOR*
JACKET JACKET
FOIL SHIELD BRAIDED SHIELD
DRAIN WIRE
DRAIN WIRE
RED & BLUE WHITE
BLACK & WHITE BLUE
YELLOW & BROWN RED
GREEN & GREY BLACK

FOIL SHIELD
INNER JACKET INNER JACKET*
*AVAILABLE ON SOME CABLE TYPES

Diagram G Diagram H
JACKET BRAIDED ARMOR* JACKET
FOIL SHIELD FOIL SHIELD
DRAIN WIRE DRAIN WIRE

BROWN GREEN
BLUE RED
YELLOW/GREEN
DEVICE GROUND
INNER JACKET*
BRAIDED SHIELD
*AVAILABLE ON SOME CABLE TYPES FOUNDATION™ fieldbus

Diagram I Diagram J
BRAIDED ARMOR* BRAIDED ARMOR
JACKET JACKET
BRAIDED SHIELD

BLUE
RED
DRAIN BROWN
GREEN

FOIL SHIELD INNER JACKET


INNER JACKET*
*AVAILABLE ON SOME CABLE TYPES

STP = Shielded Twisted Pair


Note: See page 20 for corresponding bulk cable specifications.

19 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

ics

)
lbs
nd.

rist

er

C)
t. (
Co

mb
cte
m

°
p. (
pW
gra

. of

eld
Nu
Ch t
ara
G

ke

Tem
CSA

Typ
AW
Dia

Shi

Shi
Jac
No

UL
Conductor Colors

ID
8.4 mm OD, RF51180-30M 7 90°C
STP
A 3 18 PVC, BK, 300 V, RF51180-100M 21 1 pair = (BU, BN), GN/YE, Drain (20)
Foil/Drain
* * -40°C
extremelife™-25 RF51180-200M 42

12.5 mm OD, RF51181-30M 17


STP 90°C
B 3 18 PVC, ARMOR, BK, RF51181-100M 57 1 pair = (BU, BN), GN/YE, Drain (20)
Foil/Drain
* *
-40°C
300 V, extremelife-25 RF51181-200M 114

8.4 mm OD, RF51188-30M 6


STP 90°C
A 3 18 TPE, BK, 300 V, RF51188-100M 20 1 pair = (BU, BN), GN/YE, Drain (20)
Foil/Drain
* *
-55°C
extremelife-55 RF51188-200M 40

10.4 mm OD, RF50964-30M 10


90°C
C 5 18 PVC, BU, 300 V, RF50964-100M 33 BN, WH, BK, BU, GN/YE, Drain (20) Foil/Drain * *
-40°C
extremelife-25 RF50964-200M 66

10.4 mm OD, RF51182-30M 10


2 pair = (BN, BU), (BK, WH), GN/YE, STP 90°C
D 5 18 PVC, BK, 300 V, RF51182-100M 32
Drain (20) Foil/Drain
* *
-40°C
extremelife-25 RF51182-200M 64

17.8 mm OD, RF51073-30M 31


4 pair = (BK, WH), (BU, RD), (YE, BN), STP 90°C
E 8 18 PVC, ARMOR, BU, RF51073-100M 103
(GY, GN), Drain (20) Foil/Drain
* *
-40°C
300 V, extremelife-25 RF51073-200M 206

15.1 mm OD, RF51158-30M 18


4 pair = (BK, WH), (BU, RD), (YE, BN), STP 90°C
D 8 18 TPE, BK, 300 V, RF51158-100M 60
(GY, GN), Drain (20) Foil/Drain
* *
-55°C
extremelife-55 RF51158-200M 120

13.2 mm OD, RF51183-30M 16 4 pair = (WH/BK, BK/WH), (WH/GN,


STP 90°C
D 9 18 PVC, BK, 300 V, RF51183-100M 52 GN/WH), (WH/RD, RD/WH), (WH/OG,
Foil/Drain
* *
-40°C
extremelife-25 RF51183-200M 104 OG/WH), GN/YE, Drain (20)
UL1309
15.1 mm OD, RF51189-30M 19 4 pair = (WH/BK, BK/WH), (WH/GN, IEEE 1202/FT4
STP 90°C
D 9 18 TPE, BK, 300 V, RF51189-100M 60 GN/WH), (WH/RD, RD/WH),
Foil/Drain
* * IEEE 45-1998 -55°C
extremelife-55 RF51189-200M 120 (WH/OG, OG/WH), GN/YE, Drain (20) IEEE 1580-
2001
Power Pair: 2x16 AWG = BU, WH CSA LL54185
13.5 mm OD,TPE, RB51107-30M† DCR (/1000ft) Insulation=4.1 W PVC ABS App. No.
17
16 BK, 300 V Data Pair: 2x18 AWG = BK, RD Foil/Drain 03-HS400-763- 90°C
F 4
18 Type 5728
RB51107-150M 83
DCR (/1000ft) Insulation=6.0 W XL PE Braid
* *
-55°C
RB51107-300M 165 PDA
extremelife-55 Drain (18)

Power Pair: 2x16 AWG = BU, WH


18.5 mm OD,TPE, RB51186-30M† DCR (/1000ft) Insulation=4.1W PVC
34
16 ARMOR, BK, 300 V Data Pair: 2x18 AWG = BK, RD Foil/Drain 90°C
F 4
18 Type 5729
RB51186-150M 132
DCR (/1000ft) Insulation=6.0 W XL PE Braid
* *
-55°C
RB51186-300M 264
extremelife-55 Drain (18)

8.9 mm OD,TPE, BK, RB51047-30M† Data Pair: BU, BN


7
300 V DCR (/1000ft) Insulation=6.5 W XL PE 90°C
G 3 18
Type 4910
RB51047-150M 33
Ground: GN/YE
Foil/Drain * *
-55°C
RB51047-300M 66
extremelife-55 Drain (20) FOUNDATION™ fieldbus

13 mm OD,TPE, RB51048-30M† Data Pair: BU, BN


19
ARMOR, BK, 300 V DCR (/1000ft) Insulation=6.5 W XL PE Foil/Drain 90°C
G 3 18
Type 4911
RB51048-150M 92
Ground: GN/YE
* *
-55°C
RB51048-300M 183
extremelife-55 Drain (20) FOUNDATION™ fieldbus

11.3 mm OD,TPE, RB51072-30M† Data Pair: RD, GN


10
VT, 300 V DCR (/1000ft) Insulation=16.5 W XL PE Foil/Drain 90°C
H 2 22
Type 4512
RB51072-150M 48
Drain (22) Braid
* *
-55°C
RB51072-300M 96
extremelife-55
16.5 mm OD,TPE, RB51135-30M† 26 Data Pair: RD, GN
ARMOR, VT, 300 V 128 DCR (/1000ft) Insulation=16.5 W XL PE Foil/Drain 90°C
I 2 22
Type 4513
RB51135-150M 258 Drain (22) Braid
* *
-55°C
extremelife-55 RB51135-300M 5
12.7 mm OD,TPE, RB51246-30M† Data Pair: BN, BU
18
ARMOR, YE, 300 V DCR (/1000ft) Insulation=4.1.5 W PVC 90°C
J 2 16
Type 258
RB51246-150M 90 * *
-55°C
RB51246-300M 180
extremelife-25

Network cable also available in 75 and 225 meter spools.
STP = Shielded Twisted Pair

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 20

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

4 and 5-Pin minifast ® Field Wireables

• Stainless Steel Coupling Nuts


• Male and Female Connectors
• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Specs Application Pinouts


Mates only with
female 4-pin
BSV 4148-0/9 PROFIBUS®
cordsets and
receptacles 1. BN (+ Voltage)
(pin 4 is long pin) 2. N/C
3. BU (- Voltage)
Glass filled nylon, Mates with all 4. Drain
Stainless steel coupling nut male 4-pin
BV 4148-0/9 PG 9 cable gland, cordsets and
accepts 6-8 mm receptacles
cable diameter
Male
BSV 41 .. Screw terminals, Mates only with
accepts up to 16 AWG female 4-pin
BSV 4149-0/9 conductors PROFIBUS
90°C cordsets and
600 V, 9 A receptacles
(pin 4 is long pin)

Mates with all Female


male 4-pin
BV 4149-0/9 cordsets and
Male
receptacles 1. BU (- Voltage)
2. BN (+ Voltage)
Mates only with 3. Drain
Glass filled nylon, female 4-pin 4. GN/YE (Ground)
BV 41 .. Stainless steel coupling nut Foundation™
BSV 4149-0/16
PG 16 cable gland, feildbus cordsets
accepts 12-14 mm and receptacles
cable diameter (pin 4 is long pin)
Screw terminals,
accepts up to 16 AWG Mates with all
conductors male 4-pin
BV 4149-0/16 90°C cordsets and
600 V, 9 A receptacles
Female

Mates only with Male


female 5-pin
Glass filled nylon, DeviceNet™
BSV 4157-0/13.5 Stainless steel coupling nut cordsets and
PG 13.5 cable gland, receptacles
accepts 10-12 mm (pin 3 is long pin) 1. Drain
cable diameter 2. RD (+ Voltage)
3. BK (- Voltage) Female
Screw terminals,
4. WH (CAN_H)
accepts up to 16 AWG
5. BU (CAN_L)
conductors Mates with all
90°C male 5-pin
BV 4157-0/13.5 600 V, 9 A cordsets and
receptacles

21 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

4 and 5-Pin minifast ® Field Wireables

• Nylon Coupling Nuts


• Male and Female Connectors
• NEMA 1, 3, 4, 6P and
IEC IP 67 Protection

Housing Part Number Specs Application Pinouts

Glass filled nylon


BS 4141-0/9 PG 9 cable gland,
accepts 6-8 mm cable diameter Mates with all 4-pin Male
Screw terminals, cordsets and
accepts up to 16 AWG conductors receptacles
85°C
B 4141-0/9
250 V, 9 A

BS 41 .. Female
Glass filled nylon
BS 4141-0/13.5 PG 13.5 cable gland,
accepts 10-12 mm cable diameter Mates with all 4-pin
Screw terminals, cordsets and
accepts up to 16 AWG conductors receptacles
85°C
B 4141-0/13.5
250 V, 9 A

Male
Glass filled nylon
BS 4151-0/9 PG 9 cable gland,
accepts 6-8 mm cable diameter Mates with all 5-pin
B 41 .. Screw terminals, cordsets and
accepts up to 16 AWG conductors receptacles
85°C
B 4151-0/9 Male
250 V, 9 A

Glass filled nylon


BS 4151-0/13.5 PG 13.5 cable gland,
Female accepts 10-12 mm cable diameter Mates with all 5-pin
Screw terminals, cordsets and
accepts up to 16 AWG conductors receptacles
Female
85°C
B 4151-0/13.5
250 V, 9 A

Glass filled nylon


BS 4151-0/16 PG 16 cable gland,
accepts 12-14 mm cable diameter Mates with all 5-pin
Screw terminals, cordsets and
accepts up to 16 AWG conductors receptacles
85°C
B 4151-0/16
250 V, 9 A

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 22

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

minifast ® lokfast™ Guards

• Straight and Right Angle minifast


Style Connectors

• Nylon 66

Part Number Application

LOCK-MINI
Locking guard for straight minifast standard body connectors
(RKM, RKV, RSM and RSV) in Class I, Division 2 installations*
LOCK-MINI (10/BAG)

LOCK-MINI-ANGLE
Locking guard for right angle minifast standard body connectors
(WKM, WKV, WSM and WSV) in Class I, Division 2 installations*
LOCK-MINI-ANGLE (10/BAG)

LOCK-MINI-FW
Locking guard for straight minifast field wireable connectors
(BS 41..., and B 41...) in Class I, Division 2 installations*
LOCK-MINI-FW (10/BAG)

LOCK-MINI-B&C
Consult Factory for Availability
Locking guard for straight minifast "B" Style and "C" Style connectors
(RKM, RKV, RSM and RSV) in Class I, Division 2 installations*
LOCK-MINI-B&C (10/BAG)
Consult Factory for Availability

LOCK-MINI-B&C-ANGLE
Consult Factory for Availability
Locking guard for right angle minifast "B" Style and "C" Style connectors
(WKM, WKV, WSM and WSV) in Class I, Division 2 installations*
LOCK-MINI-B&C-ANGLE (10/BAG)
Consult Factory for Availability

* See TURCK Control Drawing QCF-00147 (www.TURCK.com/fmcd/) for guidance on installation in hazardous locations.

lokfast Open lokfast Closed

23 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

minifast ® Closure Caps, Standard

• 7/8-16UN Thread
• Nickel Plated Brass and
Stainless Steel

• Male and Female Caps

Housing Part Number Specs Application


Nickel plated brass
RKM-CC 7/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to male cordsets,
Stainless steel receptacles
RKMV-CC 7/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSM-CC 7/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSMV-CC 7/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKF-CC 7/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to male
receptacles
Stainless steel
RKFV-CC 7/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSF-CC 7/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
receptacles
Stainless steel
RSFV-CC 7/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKF-MC 7/8-16UN threads
BUNA-N gasket
Closure cap, mates to male
receptacles
Stainless steel
RKFV-MC 7/8-16UN threads
BUNA-N gasket

Nickel plated brass


RSF-MC 7/8-16UN threads
BUNA-N gasket and O-ring
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSFV-MC 7/8-16UN threads
BUNA-N gasket and O-ring

Note: Add "/S1599" to the end of Part Number for closure caps assembled on cordsets.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 24

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TURCK
Process Connectivity Products

minifast ® Closure Caps, "B" Style

• 1-16UN Threads
• Nickel Plated Brass and
Stainless Steel

• Male and Female Caps

Housing Part Number Specs Application


Nickel plated brass
RKMB-CC 1-16UN threads
6" stainless steel lanyard
Closure cap, mates to male cordsets,
Stainless steel receptacles
RKMBV-CC 1-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSMB-CC 1-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSMBV-CC 1-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKFB-CC 1-16UN threads
6" stainless steel lanyard
Closure cap, mates to male
receptacles
Stainless steel
RKFBV-CC 1-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSFB-CC 1-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
receptacles
Stainless steel
RSFBV-CC 1-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKFB-MC 1-16UN threads
BUNA-N gasket and O-ring
Closure cap, mates to male
receptacles
Stainless steel
RKFBV-MC 1-16UN threads
BUNA-N gasket and O-ring

Nickel plated brass


RSFB-MC 1-16UN threads
BUNA-N gasket and O-ring
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSFBV-MC 1-16UN threads
BUNA-N gasket and O-ring

Note: Add "/S1599" to the end of Part Number for closure caps assembled on cordsets.

25 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process
Automation

minifast ® Closure Caps, "C" Style

• 11/8-16UN Threads
• Nickel Plated Brass and
Stainless Steel

• Male and Female Caps

Housing Part Number Specs Application


Nickel plated brass
RKMC-CC 11/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to male cordsets,
receptacles
Stainless steel
RKMCV-CC 11/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSMC-CC 11/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSMCV-CC 11/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKFC-CC 11/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to male
receptacles
Stainless steel
RKFCV-CC 11/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RSFC-CC 11/8-16UN threads
6" stainless steel lanyard
Closure cap, mates to female
receptacles
Stainless steel
RSFCV-CC 11/8-16UN threads
6" stainless steel lanyard

Nickel plated brass


RKFC-MC 11/8-16UN threads
BUNA-N gasket and O-ring
Closure cap, mates to male
receptacles
Stainless steel
RKFCV-MC 11/8-16UN threads
BUNA-N gasket and O-ring

Nickel plated brass


RSFC-MC 11/8-16UN threads
BUNA-N gasket and O-ring
Closure cap, mates to female
cordsets, receptacles
Stainless steel
RSFCV-MC 11/8-16UN threads
BUNA-N gasket and O-ring

Note: Add "/S1599" to the end of Part Number for closure caps assembled on cordsets.

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com 26

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
The Industry Leader in Proximity Sensing,
Connectivity, Network and Interface Products

Process
Automation
Process
Wiring
Process
Connectivity
Isolated Barriers
and Amplifiers
Interface
Solutions

Order B4100

Order B4101

Order B4000

Network Media Order B4400


excom®
Remote I/O Order B4203

AS-Interface®
Proximity
Sensors

Connectivity

Order B3000

Order B0168

Order B9040

Order B1005

Order B2004

TURCK USA TURCK Canada TURCK Mexico


TURCK Process Automation CHARTWELL TURCK Mexico S. de R.L. de C.V.
3000 Campus Drive ELECTRONICS, INC. Carr. Saltillo-Zacatecas km 4.5 s/n
Minneapolis, MN 55441 140 Duffield Drive Parque Industrial La Angostura
Phone: 1-800-544-7769 Markham, Ontario Saltillo, COAH. CP. 25070
FAX: (763) 553-0708 Canada, L6G 1B5 Phone: 011 52 (844) 482 6924
Phone: (905) 513-7100 FAX: 011 52 (844) 482-6926
FAX: (905) 513-7101 Toll Free: (Mexico only)
01-800-01-88725 (TURCK)

Printed in USA B2200 2/06


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Potrebbero piacerti anche