Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
ELECTRIC
Global partner. Local friend. FACTORY AUTOMATION
HMI
Visualisation Tools
Powerful Communication
Simple Words and Pictures
System and Process Visualisation /// Touch Screen and Key Operation ///
MITSUBISHI Powerful Maintenance Tools /// PLC Program Display /// Direct MES
ELECTRIC Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Gothaer Straße 8 /// D-40880 Ratingen /// Germany
FACTORY AUTOMATION Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// info@mitsubishi-automation.com /// www.mitsubishi-automation.com
Specifications subject to change /// Art. no. 207075-C /// 10.2009 Integration /// HMIs /// GOTs /// IPCs /// SCADA /// Software ///
All trademarks and copyrights acknowledged.
HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000
Perfect Vision
More than a terminal Advanced communication
High resolution screens offer bright
With innovative technology Mitsubishi Electric has clear displays that can be viewed from Direct Connection to a SQL database through a dedi-
created new standards in operator interaction. Fea- a wide range of angles. cated MES interface gives users greater access to oper-
tures such as the ladder monitoring function enhance Advanced screen design software ational data from across their entire plant – and all
and support the work of programmers, operators and such as GT Designer enable screens from the shop floor.
maintenance staff. to be quickly and efficiently created. Ultra-slim designs occupy less
panel space/depth.
Simple configuration
All of the HMI software packages come with
pre-defined graphic libraries to help users get started
Easier operation quickly. Some of the software programs also have sim-
ulators so that system operation can be checked
Simple intuitive keyboards are complimented by flexi- before downloading into an HMI or IPC.
ble and dynamic touch screen solutions. Each type of
HMI solution allows data to be gathered from various
FA devices and facilitates its access as information
using powerful graphic and text tools.
Intelligent design
Units with high IP ratings ensure easy
and carefree cleaning, especially
connectivity and mounting as many
units can be used in portrait or
Reliable and economical
useful for situations that require full landscape configurations. Ultra slim mounting as well as optional screen orienta-
High performance, market leading, operator terminals wash downs.
tion make Mitsubishi HMI’s simple and economical to
are the result of intelligent yet carefully planned add to almost any system. Conformance to shipping
design. For example front mounted USB ports make approvals and standards are a clear demonstration of
programming and data access simpler and quicker Mitsubishi’s commitment to quality.
than ever before. High-speed operation thanks to
fast processors.
Flexible operation allows Mitsubishi
HMIs to be used in industrial and
commercial applications.
2 3
HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000 /// E1000 /// IPC1000 /// HMI /// GOT1000
Perfect Vision
More than a terminal Advanced communication
High resolution screens offer bright
With innovative technology Mitsubishi Electric has clear displays that can be viewed from Direct Connection to a SQL database through a dedi-
created new standards in operator interaction. Fea- a wide range of angles. cated MES interface gives users greater access to oper-
tures such as the ladder monitoring function enhance Advanced screen design software ational data from across their entire plant – and all
and support the work of programmers, operators and such as GT Designer enable screens from the shop floor.
maintenance staff. to be quickly and efficiently created. Ultra-slim designs occupy less
panel space/depth.
Simple configuration
All of the HMI software packages come with
pre-defined graphic libraries to help users get started
Easier operation quickly. Some of the software programs also have sim-
ulators so that system operation can be checked
Simple intuitive keyboards are complimented by flexi- before downloading into an HMI or IPC.
ble and dynamic touch screen solutions. Each type of
HMI solution allows data to be gathered from various
FA devices and facilitates its access as information
using powerful graphic and text tools.
Intelligent design
Units with high IP ratings ensure easy
and carefree cleaning, especially
connectivity and mounting as many
units can be used in portrait or
Reliable and economical
useful for situations that require full landscape configurations. Ultra slim mounting as well as optional screen orienta-
High performance, market leading, operator terminals wash downs.
tion make Mitsubishi HMI’s simple and economical to
are the result of intelligent yet carefully planned add to almost any system. Conformance to shipping
design. For example front mounted USB ports make approvals and standards are a clear demonstration of
programming and data access simpler and quicker Mitsubishi’s commitment to quality.
than ever before. High-speed operation thanks to
fast processors.
Flexible operation allows Mitsubishi
HMIs to be used in industrial and
commercial applications.
2 3
Interfaces between human and technology /// A complete line /// Interfaces between human and technology /// A complete line /// Interfaces between human and technology
4 5
Interfaces between human and technology /// A complete line /// Interfaces between human and technology /// A complete line /// Interfaces between human and technology
4 5
Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal ///
6 7
Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal /// GOT1000 /// Graphical Operation Terminal ///
6 7
Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interfa
Highly compatible
8 9
Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interface /// E1000 /// Human Machine Interfa
Highly compatible
8 9
Industrial PCs /// IPC1000 /// Industrial PCs /// IPC1000 /// Industrial PCs /// IPC1000 /// Software package GT Works /// GT Soft /// GT Designer /// Software package GT Works /// GT W
IPC1000 – GT Works –
Industrial PCs A Complete Software Suite
쐽 The economical solution
Not all applications require full PC expan-
IPC or HMI?
sion and processing. This is exactly where
GT Works is a single software environment
the IPCs of the MicroClient series are in a
that can be used to develop screen
class of their own. These ultra compact
designs/content for either a PC/IPC or a tra-
Panel PCs provide basic PC operation and
ditional hardware unit such as the
offer a choice of 12.1” and 15” displays. The
GOT1000 series.
MicroClient solution provides entry level
PC power and rugged design all for a bud- This flexibility from a single design tool
get price. means reduced cost of ownership as users
only have to learn one software tool. In
For reducing the unit size and removing
addition there is a greater re-use of existing
one of the major moving parts that could
projects.
fail, the MicroClient panels are also
designed to operate without a cooling fan.
10 11
Industrial PCs /// IPC1000 /// Industrial PCs /// IPC1000 /// Industrial PCs /// IPC1000 /// Software package GT Works /// GT Soft /// GT Designer /// Software package GT Works /// GT W
IPC1000 – GT Works –
Industrial PCs A Complete Software Suite
쐽 The economical solution
Not all applications require full PC expan-
IPC or HMI?
sion and processing. This is exactly where
GT Works is a single software environment
the IPCs of the MicroClient series are in a
that can be used to develop screen
class of their own. These ultra compact
designs/content for either a PC/IPC or a tra-
Panel PCs provide basic PC operation and
ditional hardware unit such as the
offer a choice of 12.1” and 15” displays. The
GOT1000 series.
MicroClient solution provides entry level
PC power and rugged design all for a bud- This flexibility from a single design tool
get price. means reduced cost of ownership as users
only have to learn one software tool. In
For reducing the unit size and removing
addition there is a greater re-use of existing
one of the major moving parts that could
projects.
fail, the MicroClient panels are also
designed to operate without a cooling fan.
10 11
Software Packages /// E-Designer /// Software Packages /// E-Designer /// Software Packages /// MX4 - SCADA /// Software Packages /// MX4 - SCADA /// Software Packages /// MX4
E-Designer – MX4 –
Clear, Simple, Easy SCADA and HMI in Harmony
This is complimented by a library of Increase your Return On Assets (ROA) with
ready-to-use symbols and objects which MX4 SCADA, delivering scalable, flexible
speed up screen design and creation. and reliable control and monitoring sys-
tems that reduce your operating costs and
improve productivity. A fully integrated
Multilingual projects package, MX4 SCADA’s easy-to use config-
uration tools and powerful features enable
Users who export control systems with you to quickly develop and deploy solu-
local language displays will find E-Design- tions which can handle the most complex
ers multilingual project support a big bene- requirements for any size enterprise.
fit. Up to ten screen languages can be
loaded in to a small database allowing
operators to switch between any loaded
languages. All text blocks from the data-
base can be easily exported and imported
with the Application Languages Manager.
12 13
Software Packages /// E-Designer /// Software Packages /// E-Designer /// Software Packages /// MX4 - SCADA /// Software Packages /// MX4 - SCADA /// Software Packages /// MX4
E-Designer – MX4 –
Clear, Simple, Easy SCADA and HMI in Harmony
This is complimented by a library of Increase your Return On Assets (ROA) with
ready-to-use symbols and objects which MX4 SCADA, delivering scalable, flexible
speed up screen design and creation. and reliable control and monitoring sys-
tems that reduce your operating costs and
improve productivity. A fully integrated
Multilingual projects package, MX4 SCADA’s easy-to use config-
uration tools and powerful features enable
Users who export control systems with you to quickly develop and deploy solu-
local language displays will find E-Design- tions which can handle the most complex
ers multilingual project support a big bene- requirements for any size enterprise.
fit. Up to ten screen languages can be
loaded in to a small database allowing
operators to switch between any loaded
languages. All text blocks from the data-
base can be easily exported and imported
with the Application Languages Manager.
12 13
Visualisation and productivity /// Visualisation and productivity /// Automation solutions /// Automation solutions /// Automation solutions /// Automation solutions /// Automation
Visualisation A world of
and productivity automation solutions
In fact some HMIs have the ability to report Robots
Enterprise PC Servo amplifiers
(MES/ERP/SCADA) errors remotely, even contacting the main-
tenance team before the line operators are Motion control and servos
aware there is a problem. The potential of
LV circuit protection Inverters
visualisation tools to improve process
“uptime” is enormous.
Remote I/Os
Micro PLCs
14 15
/// GOT1000 /// E1000 /// IPC1000 ///
More information?
This product catalogue is designed to give an overview of the extensive range of operator terminals of the GOT1000, E1000 series and Indus-
trial PCs and Visualization software. If you cannot find the information you require in this catalogue, there are a number of ways you can get
further details on configuration and technical issues, pricing and availability.
For technical issues visit the www.mitsubishi-automation.com website.
Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and
services. Manuals and catalogues are available in several different languages and can be downloaded for free.
For technical, configuration, pricing and availability issues contact our distributors and partners.
Mitsubishi partners and distributors are only too happy to help answer your technical questions or help with configuration building.
For a list of Mitsubishi partners please see the back of this catalogue or alternatively take a look at the “contact us” section of our website.
2 MITSUBISHI ELECTRIC
/// CONTENTS
MITSUBISHI ELECTRIC 3
/// INTRODUCTION AND CONFIGURATION
6
4 5
with a PC running the intuitive Windows- MNOP
1
QRST
2
UVWX
3
YZ!? C1-C4 < >()
ü
machines and require nearly no additional ALARM ACK
Vision 1000
Mitsubishi Electric's Vision 1000 contains terminals, IPCs, and visualization software, proprietary and open solutions, exactly co-
different product lines for human- machine and summarizes them as a concept, with ordinated with the respective application.
communication, e.g. operator
GOT series GT10 (14 models) GT11 (5 models) GT15 (22 models) GT16 (12 models)
Display dimensions 3.7"/ 4.5" / 4.7" / 5.7" 5.7" 5.7" – 15" 8.4" – 15"
text (lines x characters) User definable User definable User definable User definable
graphical resolution (pixels) 160x64 / 288x96 / 320x240 320x240 320x240 to 1024x768 680x480 to 1024x768
Power supply 5 V DC / 24 V DC 24 V DC 24 V DC / 220 V AC 24 V DC / 220 V AC
Network possibilities Serial Serial Ethernet (TCP/IP), CC-Link (IE), RS232, RS422, RS485, A-Bus, Q-Bus,
MELSECNET/10/H, Modbus TCP
IP Rating (front panel) IP67 IP67 / IP65 (portable models) IP67 IP67
4 MITSUBISHI ELECTRIC
INTRODUCTION AND CONFIGURATION ///
4
MNOP
1
YZ!?
-
+/*=
ç
8
EFGH
5
QRST
2
C1-C4
5
°%#
9
IJKL
6
UVWX
3
< >()
è
.
_'@,
ETHERNET devices and data exchange are all standard 1
features in today’s factory automation sys-
PREV HOME NEXT
ü
ALARM ACK
6 ü
4 5 ALARM ACK
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
P R O F I
means you can monitor and edit your con-
PROCESS FIELD BUS
B U S
figuration, programs and data from the
7
ABCD
4
MNOP
1
YZ!?
-
+/*=
8
EFGH
5
QRST
2
C1-C4
5
°%#
9
IJKL
6
UVWX
3
< >()
.
_'@,
ç
PREV HOME
ALARM
è
NEXT
ü
ACK
comfort of your desk.
7 8 9
ABCD EFGH IJKL
4 5 6
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
°%# _'@,
Interfaces
+/*=
ç è
PREV HOME NEXT
ü
ALARM ACK
앬 RS422
앬 RS232C
앬 RS485/RS422*
앬 MELSEC A-BUS*
앬 Modem Links 앬 PROFIBUS/DP
앬 MELSEC Q-BUS*
Enables connections over larger E series control units can be connected
distances. as slaves in systems using the open field 앬 PROFIBUS/DP*
앬 Ethernet bus protocol. 앬 Modbus TCP*
앬 Multidrop-Net 앬 Ethernet TCP/IP (coaxial or twisted
Enables programming and data logging pair)*
from a central location using a PC; the 앬 CC-Link*
앬 MELSECNET/10/H and CC-Link IE individual stations operate autonomous- 앬 USB*
Enables high-speed access (up to ly and independently of one another. *Standard or optional dependent on the operator
1 Gbaud) to the PLC from multiple 앬 No-Protocoll-Link terminal type
locations via the GT15. Enables connection of barcode readers
앬 Multi Driver support and other serial devices to the PLC via
The control units can be used e.g. as the E series control units.
a gateway between 2 systems (E1000) 앬 A-BUS/Q-BUS
and a gateway between 4 systems Direct connection of the GT15 /GT16
(GT15/GT16). to the PLC’s expansion port for fast
communications.
type LCD, mono- LCD, mono- LCD, mono- TFT TFT TFT TFT TFT TFT
chrome chrome chrome
Display dimensions 89.6x17.9 mm 90.2x24.0 mm 135x36 mm 3.5" 5.7" 5.7" 6.5" 10.4" 15"
text (lines x characters) User definable
graphical resolution (pixels) 160 x32 240x64 240x64 320x240 320x240 320x240 640x480 800x600 1024x768
Power supply 24 V DC (20 – 30 V)
Keyboard Membrane Membrane Membrane Touch-panel Membrane Touch-panel Membrane/ Membrane/ Touch-panel
Touch-panel Touch-panel
Function keys Yes Yes Yes Touch keys Yes Touch keys Yes/Touch keys Yes/Touch keys Touch keys
serial RS232, RS422 / RS232
Interfaces
others — — USB USB USB USB USB USB USB
Network possibilities Ethernet (TCP/IP) (optional) Ethernet (TCP/IP), Modbus TCP, MPI (all integrated); Profibus/DP (optional)
IP Rating (front panel) IP66
MITSUBISHI ELECTRIC 5
/// OPERATOR TERMINALS GOT
GOT1000
Complex processes displayed simply With the GOT1000 the user accesses all A vast number of indicating instruments
MELSEC PLCs special function modules in like indicators, pressure gauges, analog and
The graphic operator terminals of the
order to test individual parts of the plant. digital measuring devices, etc. can be
GOT1000 series represent the top products
The PLC programs can be monitored graph- replaced by corresponding graphical
by MITSUBISHI ELECTRIC.They provide a
ically (ladder diagram). objects.
high-resolution fully graphical display and a
touch-sensitive user surface. The depth of The control units are programmed with Lots of ready-to-use practical objects are
only 50 mm makes it to one of the slimmest the GT Works software package running on included in the MS Windows® compatible
2 operator panel on the market. State
changes and user inputs can be entered
a PC under MS Windows®.
Programs can be stored either in the control
programming software and reduce pro-
gram development time.
easily. unit’s integrated, battery-powered RAM, in All units feature an integrated real-time
plug-in EPROM modules or on Compact
OPERATOR TERMINALS GOT
The 64-bit RISC processor used in the clock, password access control and alarm
flash memory cards. and recipe handling.
GOT1000 series is combined with a specially
developed high-speed graphics processor. The GOT1000 features Unicode 2.1 support.
Together, they deliver impressive response This enables users to easily create multi-lan-
and display drawing times. guage displays.
MELSECNET/10/H, CC-Link (IE) and Ethernet In perfect interaction with the powerful iQ
as well as the four-driver-concept (4 drivers platform this function helps to decrease
at the same time and the possibility of data downtimes.
6 MITSUBISHI ELECTRIC
OPERATOR TERMINALS GOT ///
GT1020/GT1030
GT01-C30R2-6P GT10-C30R2-6P/EN
2
GT10-C30R4-8P
QJ71BR11
QY80 Q64AD RUN MNG
QX80 T.PASS D.LINK
Q06HCPU 01234567 RUN RD
Q06HCPU 01234567 SD
89ABCDEF ERROR L ERR.
89ABCDEF FUSE ERR.
POWER MODE
MELSEC MODE
RUN
Q61P-A2 V+
RUN L
ERR. C STATION NO.
ERR. L
1 H
V-
USER 1 X10
USER 2
1 I+
BAT. 2 L
BAT. SLD
BOOT L
3 X1
BOOT 3
4 L
4
0 C
V+
0
0 L
5 H
V-
1 MODE
5
1 1 2 I+
6 L
6
2 2
7
2 L
7 SLD
3
3 8 3 V+
8 L
4 C
V-
4
BASE UNIT
MODEL Q38B 9 4 L
9 H
3 5
5 A 5 I+
SERIAL 0205020E A L
6
6 L
B 6 SLD
PULL
B
C 7 V+ 7
PULL C 7 L
C V- 8
8 L
D 8 H
D
E 9 4 I+ 9
USB
USB E 9 L
F SLD
F L
COM A.G.
PULL NC
(FG)
COM
X15 A/D
X3 X5 X7 X11 X13 12VDC
X1 X14 0~±10V
100-240 S/S
X2 X4 X6 X10 X12 24VDC
L N X0 0~20mA
VAC 24VDC 0.5A
0 1 2 3
4 5 6 7
RS-232 4mA
8 9 10 11
RS-232
12 13 14 15 QJ71BR11
MITSUBISHI IN
POWER MITSUBISHI
RUN
ERROR
FX1N-24MR
OUT
0 1 2 3
4 5 6 7
10 11
MELSEC System Q
24MR
Y3 Y5 Y6 Y10 -ES/UL
Y1 Y2 Y11
0V Y0 COM4 Y7
COM2 COM3 Y4
24+ COM0 COM1
QY80 Q64AD
QJ71BR11
RUN MNG
GT01-C30R2-GP GT01-C30R2-9S
QX80 T.PASS D.LINK
Q06HCPU 01234567 RUN RD
Q06HCPU 01234567 SD
89ABCDEF ERROR L ERR.
89ABCDEF FUSE ERR.
POWER MODE
MELSEC MODE
RUN
Q61P-A2 V+
RUN L
ERR. C STATION NO.
ERR. L
1 H
V-
USER 1 X10
USER 2
1 I+
BAT. 2 L
BAT. SLD
BOOT L
3 X1
BOOT 3
4 L
4
0 C
V+
0
0 L
5 H
V-
1 MODE
5
1 1 2 I+
6 L
6
2 2
7
2 L
7 SLD
3
3 8 3 V+
8 L
4 C
V-
4
BASE UNIT
MODEL Q38B 9 4 L
9 H
3 5
5 A 5 I+
SERIAL 0205020E A L
6
6 L
B 6 SLD
PULL
B
C 7 V+ 7
PULL C 7 L
C V- 8
8 L
D 8 H
GT01-C30R4-25P
D
E 9 4 I+ 9
USB
USB E 9 L
F SLD
F L
COM A.G.
PULL NC
(FG)
COM
A/D
12VDC
0~±10V
24VDC
24VDC 0~20mA
0.5A
RS-232 4mA
RS-232
QJ71BR11
MITSUBISHI
MELSEC System Q
GT01-C30R4-8P
X15
X3 X5 X7 X11 X13
X1 X14
100-240 S/S
X2 X4 X6 X10 X12
L N X0
VAC
0 1 2 3
4 5 6 7
8 9 10 11
12 13 14 15
MITSUBISHI IN
POWER
RUN
ERROR
Personal Computer
FX1N-24MR
OUT
0 1 2 3
4 5 6 7
10 11
24MR
Y3 Y5 Y6 Y10 -ES/UL
Y1 Y2 Y11
0V Y0 COM4 Y7
COM2 COM3 Y4
24+ COM0 COM1
MITSUBISHI ELECTRIC 7
/// OPERATOR TERMINALS GOT
MITSUBISHI
MITSUBISHI
MITSUBISHI
2
OPERATOR TERMINALS GOT
The micro GOTs GT1020 and GT1030 offer The new models GT1040 and GT1050 Apart from many automation components
a bright monochrome STN 3.7“ or 4.5“ provide a 2-colour (16 scales of blue/white) of MITSUBISHI ELECTRIC also devices of
display with touchscreen functionality and STN display, GT1045 and GT1055 a 256 third party manufacturers and PCs can be
tri-colour background illumination (LBDW colour STN display. The monitor sizes of connected. The integrated high-speed USB
and LBLW models, also with white GT1040/GT1045 amount to 4.7” and of interface (not available for GT1020/GT1030)
background available) for a broad variety of GT1050/GT1055 amount to 5.7”. All displays allows the programming of Mitsubishi PLCs,
applications. feature a graphical resolution of 320x240 frequency inverters and servo amplifiers by
Small in dimensions, the versatile micro pixels and are designed as touch screens. using transparent mode.
GOTs offer a number of outstanding The internal memory, used for projects and All GOT1000 can be programmed easily via
powerful features. Different fonts and system data, is 3 MB. This is twice as big as PC with the software package GT Designer 2.
languages can be used, and when an error the memory of a GT1030. With an option All GOT1000 panels can be mounted and
occurs the background can be light-up in module it is possible to save GOT project used horizontal or vertical, which increases
red as an eye catcher. data. Suitable connection cables for the the flexibility in planning and application.
They are available with an RS422 (LBL and back side interfaces (e.g. USB, RS422, and
LBD models) or RS232 (LBL2 and LBD2 RS232) are available, too.
models) programming interface.
Order information Art. no. 200738 / 200491 / 200492 / 208670 / 208668 / 208669
206969 / 206970 / 206971 / 206972
221929
218492
221930
218491
Accessories Programming software (refer to page 39), cables and interface adapters (refer to page 18)
8 MITSUBISHI ELECTRIC
OPERATOR TERMINALS GOT ///
MITSUBISHI
POWER
2
The GT11 series graphic operating The GT1150HS-QLBD and The GT1550 and GT1555 models provide
terminals GT1150-QLBD and GT1155HS-QSBD are handsome portable an exceptionally clear 5.7“ display compris-
GT1150HS-QLBD (display with 16 grey terminals that boast top level quality for ing 16 grey scale steps over 4,096 colours
scales), GT1155-QSBD and medium sized terminals. They share the up to 65,536 colours and full VGA resolution
GT1155HS-QSBD (256 colours) are the same functions as all GT11 series terminals. quality (640x480 pixels).
standard models of the versatile GOT1000 Mitsubishi Electric Controllers, inverters and Windows fonts are utilized for clear text pre-
series. They offer a wide range of basic servo amplifiers can be easily programmed sentation as well as CF card interface for
functions for stand-alone use. via the transparent USB functionality. project operation systems and data storage
Beside their outstanding speed and perfor- All GT11 terminals feature recipes, alarms, are available.
mance they features a modern design and a multi-language and Unicode support. These models open the door to visualiza-
first on the market front USB port for project Furthermore they offer various graphical tion of complex processes with modern
download and PLC maintenance. object libraries. functions and full network support.
The panels can be mounted and used hori-
zontally or vertically.
MITSUBISHI ELECTRIC 9
/// OPERATOR TERMINALS GOT
2
POWER
POWER POWER POWER
OPERATOR TERMINALS GOT
The proprietary operating MELSEC PLCs can easily be In terms of networks, the GT15 The Video models
system as well as the programmed using the front are especially powerful with GT1585V-STBD and
completely new developed USB port with integrated options for MELSECNET/10/H, GT1575V-STBD additionally
hardware result in an outstand- Transparent Mode, so updates CC-Link (IE) and Ethernet as well support video/RGB input to
ing performance and quality of on PLCs, servo amplifiers, as the four-driver-concept (4 monitor images from PC's,
the GT15 operator terminals. inverters and GOT terminals drivers at the same time and the cameras and vision sensors
The user can choose between can be accomplished without possibility of data exchange via directly on the GOT.
several fast project up- and opening the cabinet. gateway between the drivers as All GT15 operator terminals
download options; high-speed The file system of the CF card is well as third party manufactur- listed on this page are available
serial connection with 115 PC compatible. Projects and ers). as AC type ( models*) or as DC
kBaud, USB or project transfer operating system components By using an MES option card the type ( models).
via CF-card is available. can be downloaded to the CF GT15 are able to communicate *Not for the video models
In addition, the GT15 offer card. The GT15 can load the files direct with Windows databases
Ethernet project transfer via the from the CF card. This is a without needing a Gateway-PC.
optional Ethernet interface crucial advantage for manufac-
GT15-J71E71-100. turers of serial machines.
Accessories Programming software (refer to page 39), cables and interface adapters (refer to page 18)
10 MITSUBISHI ELECTRIC
OPERATOR TERMINALS GOT ///
The new all-in-one models of Using separate expansions units The high-resolution TFT monitor bleshooting videos or to record
the GT16 series are packed with it is very easy to upgrade the shows pictures, windows, dia- and analyze event-driven videos.
all the solutions to meet the GT16 with special functions or grams and touchkeys in highest The build-in Self-diagnosis func-
needs of customers. This leads additional interfaces. The quality and up to 65536 colours. tion recognizes problems and
GT16 terminals to become full high-speed USB ports on the All screens can be created indi- plays an instruction video or
components of system control front panel allow the user to vidually with the GT Designer 2 shows helpful hints. In perfect
management. save and restore project data software, installed on a standard interaction with the powerful iQ
Many of the well-known useful and PLC programs via standard PC. Every item can be moved platform this function helps to
functions are already integrated, USB memory sticks. This is very freely on the whole monitor. decrease downtimes.
e.g. avariety of networkconnec- helpful if the PLC CPU needs to This makes using easier even for
Using an MES option card GT16
tionssuchasEthernet and RS422/ be exchanged. The PLC program complex applications.
operator terminals can
RS485 beside the generously can be backuped and restored Up to four CCD cameras can be communicate directly with
measured project and data plus saving of historical informa- connected, and with an installed Windows databases without the
memory of 15 MB (with CF card tion (e.g. trends, alarms) using multimedia option card it is pos- need of a gateway PC.
expandable up to 57 MB max.). the USB port of the GT16. sible to play prerecorded trou-
Display unit text (lines x characters) User definable User definable User definable User definable
character height (mm) User definable, Windows fonts User definable, Windows fonts User definable, Windows fonts User definable, Windows fonts
STB첸: 800x600
graphical resolution (pixels) VTB첸: STB첸: 800x600 800x600 (SVGA) 1024x768 (XGA)
640x480 VTB첸: 640x480
A types 100 – 240 V AC 100 – 240 V AC 100 – 240 V AC 100 – 240 V AC
Power supply
D types 24 V DC 24 V DC 24 V DC 24 V DC
Memory capacity 15 MB 15 MB 15 MB 15 MB (expandable up to 57 MB)
Internal memory capacity 1 (compact flash) 1 (compact flash) 1 (compact flash) 1 (compact flash)
Keyboard type Touch-panel Touch-panel Touch-panel Touch-panel
internal Touch keys Touch keys Touch keys Touch keys
Function keys
external — — — —
LED indicators 1 (POWER) 1 (POWER) 1 (POWER) 1 (POWER)
Interfaces Ethernet (TCP/IP), RS232, RS422/485, USB (front), CF slot, Human sensor, optional: function cards
Interface slot for optional cards 1 CF-Slot 1 CF-Slot 1 CF-Slot 1 CF-Slot
Multimedia capability Integrated Integrated Integrated Optional
Real-time clock Integrated Integrated Integrated Integrated
Network communication possibilities Ethernet (TCP/IP), CC-Link (IE), Modbus, RS232, RS422/485, A-Bus, Q-Bus, MELSECNET/10/H
IP Rating (front panel) IP67 IP67 IP67 IP67
Dimensions WxHxD (mm) 241x190x52 303x214x49 316x242x52 397x296x61
Weight (kg) 1.7 2.1 2.7 5.0
Accessories Programming software (refer to page 39), cables and interface adapters (refer to page 18)
MITSUBISHI ELECTRIC 11
/// OPERATOR TERMINALS E SERIES
4 L
4
0 C
V+
0
0 L
5 H
V-
1 MODE
5
1 1 2 I+
6 L
6
2 2
7
2 L
7 SLD
3
3 8 3 V+
PULL
B L
C 7 V+ 7
PULL C 7 L
C V- 8
8 L
D 8 H
D
E 9 4 I+ 9
USB
USB E 9 L
F SLD
F L
COM A.G.
PULL NC
(FG)
COM
A/D
12VDC
0~±10V
24VDC
24VDC 0~20mA
0.5A
RS-232 4mA
RS-232
QJ71BR11
MITSUBISHI
7 8 9
ABCD EFGH IJKL
4 5 6
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
ç è
PREV HOME NEXT
ü
ALARM ACK
1
QRST
2
UVWX
3
text blocks is not limited by the number of
YZ!?
-
C1-C4
5
°%#
< >()
.
_'@,
lines on the screen.
+/*=
ç
PREV HOME
è
NEXT
The blocks can be output to a printer under
ALARM ACK
ü
PLC control.
The graphics block size is limited by the
display which has a resolution of
240x64 pixel up to 1024x768 pixel.
Static objects for example, can be displayed
in different font sizes or with predefined
graphic objects.
Dynamic objects are predefined as well for
easier application development and can be
scaled to any size.
In addition to these predefined objects
self-created bitmap graphics can be
7
ABCD
8
EFGH
9
IJKL
ç
PREV HOME
è
NEXT
imported and managed in libraries.
6 ü
4 5 ALARM ACK
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
12 MITSUBISHI ELECTRIC
OPERATOR TERMINALS E SERIES ///
Communications
All E series control units are fitted with an
RS232C RS422 and an RS232 interface for connec-
tion to the PLC.
7
ABCD
4
MNOP
1
8
EFGH
5
QRST
2
9
IJKL
6
UVWX
3
ç
PREV HOME
ALARM
è
NEXT
ü
ACK
This second port enables the unit to be run
in transparent mode.
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
4 5 6 4 5 6
MNOP QRST UVWX MNOP QRST UVWX
1 2 3 1 2 3
YZ!? C1-C4 < >() YZ!? C1-C4 < >()
- 5 . - 5 .
+/*= °%# _'@, +/*= °%# _'@,
ç è ç è
PREV HOME NEXT PREV HOME NEXT
ü ü
ALARM ACK ALARM ACK
ç è
7 8 9 HOME NEXT
PREV
ABCD EFGH IJKL
6 ü
4 5 ALARM ACK
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
Networking Ethernet
All E1000 operator terminals feature an
integrated Ethernet adapter to realize an
Ethernet network.
7 8 9
ABCD EFGH IJKL
4 5 6
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
ç è
PREV HOME NEXT
ç è ç è
7 8 9 HOME NEXT 7 8 9 HOME NEXT
PREV PREV
ABCD EFGH IJKL ABCD EFGH IJKL
6 ü 6 ü
4 5 ALARM ACK 4 5 ALARM ACK
MNOP QRST UVWX MNOP QRST UVWX
2 3 2 3
- 5 . - 5 .
+/*= °%# _'@, +/*= °%# _'@,
4
MNOP
1
YZ!?
8
EFGH
5
QRST
2
C1-C4
9
IJKL
6
UVWX
3
< >()
- 5 .
+/*= °%# _'@,
ç è
PREV HOME NEXT
ü
ALARM ACK
PROFIBUS/DP
Dual Driver
The operator terminal can communicate
with two components of different manufac-
tures; also data exchange between the two
drivers is possible. 7
ABCD
4
MNOP
1
8
EFGH
5
QRST
2
9
IJKL
6
UVWX
3
ç
PREV HOME
ALARM
è
NEXT
ü
ACK
- 5 .
+/*= °%# _'@,
MITSUBISHI ELECTRIC 13
/// OPERATOR TERMINALS E SERIES
7 8 9
ABCD EFGH IJKL
4 5 6
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
ç è
PREV HOME NEXT
è ü
8 9 ç
7 PREV HOME NEXT
ALARM ACK
6 ü
4 5 ALARM ACK
MNOP QRST UVWX
1 2 3
YZ!? C1-C4 < >()
- 5 .
+/*= °%# _'@,
6
3
OPERATOR TERMINALS E SERIES
E1012, E1022 and E1032 have The E1041 and E1043 termi- The E1060 and E1062 units More features of the E1060 to
programmable function keys nals have a 3.5" TFT touch provide a 5.7” TFT display with E1063 are: Recipes,text and
and a separate keypad. The screen (65,536 colours or 16 65,536 colours or 2 colours editing changes are entered via
graphic-capable displays illus- grey scales). Recipes, text and (blue/white). Both models keys. Password levels protect
trate symbols, alarms, line dia- editing changes are entered via feature screen-oriented the system against unauthor-
grams and text in arbitrary keys. Password levels protect function keys for user- friendly ised access, while sixteen
sizes. Formulas, text and the system against unauthor- operation. separate alarm groups keep
changes in the sequence pro- ised access, while sixteen sepa- The E1061 and E1063 terminals you informed on all-important
gram can be done directly via rate alarm groups keep you have a 5.7" TFT touch screen developments.
the keys. informed on all-important de- (65,536 colours or 16 grey Each unit features two PLC
velopments. The unit features scales). Recipes, text and editing ports, one USB host port to con-
two PLC ports, a USB host port changes are entered via touch nect mouse, keyboard, printer
to connect mouse, keyboard, keys on the display. and USB memory sticks as well
printer and USB memory as well as an integrated Ethernet inter-
as an integrated Ethernet inter- face.
face. Profibus/DP is available via
Profibus/DP is available via a
a separate extension module.
separate extension module.
Specifications E1012 / E1022 E1032 E1041 / E1043 E1060 / E1062 E1061 / E1063
type LCD monochrome LCD monochrome TFT colour / TFT grey scale TFT colour / TFT grey scale TFT colour / TFT grey scale
dimensions (mm) 89.6x17.9 / 90.2x24.0 135x36 75x54 (3.5") 120x91 (5.7") 145x110 (5.7")
Display unit text (lines x characters) User definable User definable User definable User definable User definable
character height (mm) User definable, Windows fonts User definable, Windows fonts User definable, Windows fonts User definable, Windows fonts User definable, Windows fonts
graphical resolution (pixels) 160x32 / 240x64 240x64 320x240 320x240 320x240
Power supply 24 V DC (20 – 30 V) 24 V DC (20 – 30 V) 24 V DC (20 – 30 V) 24 V DC (20 – 30 V) 24 V DC (20 – 30 V)
Internal memory capacity 512 kB 12 MB 12 MB 12 MB 12 MB
Flash memory — 32 MB (Intel Strata Flash) 32 MB (Intel Strata Flash) 32 MB (Intel Strata Flash) 32 MB (Intel Strata Flash)
Keyboard type Membrane Membrane Touch-panel Membrane Touch-panel
internal 6 8 Touch keys 16 Touch keys
Function keys
external — — — — —
LED indicators 6 (integrated in keys) 16 (8 integrated in keys) 1 (Power ON) 16 (8 integrated in keys) 1 (Power ON)
serial RS232C, RS422/RS485 RS232C, RS422/RS485 RS232C, RS422/RS485 RS232C, RS422/RS485 RS232C, RS422/RS485
Interfaces parallel — — — — —
others — USB USB USB USB
Interface slot for optional cards 1 1 1 1 1
Real-time clock Integrated Integrated Integrated Integrated Integrated
Ethernet (TCP/IP), Modbus Ethernet (TCP/IP), Modbus Ethernet (TCP/IP), Modbus Ethernet (TCP/IP), Modbus
Network communication possibilities Ethernet (TCP/IP) (optional) TCP, MPI (all integrated); TCP, MPI (all integrated); TCP, MPI (all integrated); TCP, MPI (all integrated);
Profibus/DP (optional) Profibus/DP (optional) Profibus/DP (optional) Profibus/DP (optional)
IP Rating (front panel) IP 66 IP 66 IP 66 IP 66 IP 66
Dimensions WxHxD (mm) 155x114x40 / 155x155x41 202x187x63 156x119x63 275x168x63 201x152x63
Weight (kg) 0.4 / 0.5 0.9 0.56 1.1 0.87
Order information Art. no. 202084 / 202085 169297 169298 / 169299 216254 / 216306 216305 / 216307
Accessories Programming software E-Designer (refer to page 40), cables and interface adapters (refer to page 18)
14 MITSUBISHI ELECTRIC
OPERATOR TERMINALS E SERIES ///
9 7 8 9
7 8 EFGH IJKL
IJKL ABCD
ABCD EFGH
5 6 4 5 6
4 QRST UVWX
UVWX MNOP
MNOP QRST
1 2 3 1 2 3
YZ!? C1-C4 < >()
YZ!? C1-C4 < >()
. - 5 .
- 5
_'@, +/*= °%# _'@,
+/*= °%#
ç è ç è
HOME NEXT PREV HOME NEXT
PREV
ü ü
ALARM ACK ALARM ACK
6
7
Network communication possibilities Ethernet TCP/IP, Modbus TCP, MPI Ethernet TCP/IP, Modbus TCP, MPI Ethernet TCP/IP, Modbus TCP, MPI Ethernet TCP/IP, Modbus TCP, MPI
(all integrated); Profibus/DP (optional) (all integrated); Profibus/DP (optional) (all integrated); Profibus/DP (optional) (all integrated); Profibus/DP (optional)
IP Rating (front panel) IP65 IP65 IP65 IP65
Dimensions WxHxD (mm) 285x177x62 219x154x61 382x252x64 302x228x64 , 398x304x60
Weight (kg) 1.3 1.1 2.3 2.0 / 3.7
Order information Art. no. 156096 / 203301 156097 / 203302 156098 / 203303 156099 / 203324
156100 / 203325 / DT1151: 203326
Accessories Programming software E-Designer (refer to page 40), cables and interface adapters (refer to page 18)
MITSUBISHI ELECTRIC 15
/// INDUSTRIAL PC'S
Personal computers are a part The ETX technology permits A wide operating and storage The CANopen, DeviceNet or
of everyday life as Industrial PCs scalable CPU performances for temperature range, tough Profibus field buses can option-
4 are a part of automation and
process control.
a wide range of industrial appli-
cations.
vibration resistance and high IP
ratings mean these IPCs can be
ally be integrated directly on
board of the V panels.
The IPC1000 line based on ETX Ruggedly designed for used in locations users could
INDUSTRIAL PCs
16 MITSUBISHI ELECTRIC
ACCESSORIES ///
The HMI communications and interface Adapter type (use) Interface name Application Order number
adapters support connection directly to a GT15-75ABUSSL GT15/GT16 (1 channel), slim model 166243
PLC or directly to a network. GT15-ABUS GT15/GT16 (1 channel), standard model 169467
All GT15 modules can be used for the new MELSEC A-Bus interface
GT15-75ABUS2SL GT15/GT16 (2 channels), slim model 166304
GT16 terminals, too, except the Ethernet
GT15-ABUS2 GT15/GT16 (2 channels), standard model 169468
module GT15-J71E71-100.
GT15-75QBUSSL GT15/GT16 (1 channel), slim model 166305
Further details on request.
GT15-QBUS GT15/GT16 (1 channel), standard model 169465
MELSEC Q-Bus interface
GT15-75QBUS2SL GT15/GT16 (2 channels), slim model 166306
GT15-QBUS2 GT15/GT16 (2 channels), standard model 169466
Ethernet RJ45 GT15-J71E71-100 GT15 166309
GT15-RS2-9P GT15/GT16 (serial interface RS232, 9-pin D-Sub) 169469
GT15-RS2T4-9P GT15/GT16 (converter RS232 -> RS422; 9-pin D-Sub) 166307
Serial interface GT15-RS4-9S GT15/GT16 (serial interface RS422/485, 9-pin D-Sub) 169470
GT15-RS4-TS GT15/GT16 (serial interface RS422/485, screw terminals) 169471
GT15-RS2T4-25P GT15/GT16 (converter RS232 -> RS422; 25-pin D-Sub) 166308
GT15-J61BT13 GT15/GT16 203494
CC-Link interface
GT15-J71GP23-SX GT15/GT16, CCLink IE interface, 1 GBaud, optical ring 218576
GT15-J71BR13 GT15/GT16 (for coaxial connection) 229843
MELSECNET/10/H
GT15-J71LP23-25 GT15/GT16 (for optical SI cable) 229842
USB GT15-PRN GT15/GT16 (for USB connection to pictbridge compatible
printers) 170169
MES option card (for direct GT15-MESB48M GT15 option card with 48 MB expansion memory and
MES functionality 203473
5
database connection)
GT16M-MESB GT16 option card with MES functionality 221369
ACCESSORIES
왎 Option Cards for GT15
The operator terminals of the GT15 series are Option card Application Order number
able to use several special functions built into Option card for the use of special functions
GT15-FNB 166313
the terminal. To use multi-channel communi- (without System Q support)
cation, document display, System Q ladder Option card for the use of special functions
GT15-QFNB 166314
monitor and MES functionality an option (with System Q support)
board is required. They are fitted in the expan- Option card for the use of special functions
GT15-QFNB16M 166315
sion slot on the rear side of the terminal and (with System Q support and 16 MB expansion memory for project data)
are recognized automatically by the GT15. Option card for the use of special functions
GT15-QFNB32M (with System Q support and 32 MB expansion memory for project data) 166316
Further details on request.
GT15-QFNB48M Option card for the use of special functions
(with System Q support and 48 MB expansion memory for project data) 166317
Video interfaces can be used with the Video unit Application Order number
GT15/GT16 video panels to support video GT15V-75V4 Video input unit for GT15 video compatible models, 4 x NTSC/PAL inputs 203497
functions. With the help of these interfaces,
GT15V-75R1 Video input unit for GT15 video compatible models, 1 x RGB composite input 203498
images from PC's, cameras and vision sensors
can be monitored on the GOT. GT15V-75V4R1 Video input unit for GT15 video compatible models, 4 x NTSC/PAL inputs,
1 x RGB composite input 203499
Further details on request.
GT15V-75ROUT Video input unit for GT15 video compatible models, 1 x RGB composite output 203500
GT16M-MMR GOT multimedia option board for GT16 HMIs 221362
GT16M-V4 GOT Video Input Unit for GT16 HMIs, 4x NTSC/PAL inputs 75 Ohm 221363
GT16M-V4R1 GOT Video Input Unit for GT16, 4x NTSC/PAL inputs, 1x RGB composite input 221364
GT16M-R2 GOT Video Input Unit for GT16 HMIs, 2x RGB composite input 221365
GT16M-ROUT GOT Video Output Unit for GT16, 1x RGB composite output 221366
MITSUBISHI ELECTRIC 17
/// ACCESSORIES
왎 Cables
For all GOT and E series operator terminals All cables have to be ordered separately The length for all cables is 3.0 m, if not dif-
is a wide variety of different cables avail- due to the specific application. ferently indicated.
able.
Programming cable
18 MITSUBISHI ELECTRIC
ACCESSORIES ///
왎 Cables
ACCESSORIES
E1000 RS232 D-SUB female CAB30
D-SUB female Personal Computer 163002
connector 9 pin connector 9 pin
* GOT RS422/RS485 cable adapter, 0.2 m. This adapter is to be used with a standard GOT1000 communication cable, e.g. GT01-C30R4-8P.
MITSUBISHI ELECTRIC 19
/// ACCESSORIES
These cables can only be used for the con- CAB30 is a connection cable for E1000 CAB11 can also be used for GOT1000 series
nection of an GOT1000 or E1000 operator series terminals, it connects the Siemens (with selfmade GT11+GT15 cable).
terminal to a Third Party Manufacturer PLC. HMI adapter for MPI with the RS232 port. Below an example is shown.
They all have the name CAB with a specific CAB8 is a communications adapter for
number. RS485 networks by using the RS422 port.
CAB11 is an HMI adapter cable for the con-
nection of a Siemens SIMATIC S7/MPI with
CAB30 (for E1000 series).
GT11H-C30-37P / GT11H-C30 /
Specifications GT11H-C60-37P / GT11H-C60 / GT11H-C15R4-8P GT11H-C15R4-25P GT11H-C15R2-6P
GT11H-C100-37P GT11H-C100
Cable type External cable for GT11 handy External cable for GT11 handy Relay cable Relay cable Relay cable
Connector 1 Round female connector 32 pin Round female connector 32 pin D-SUB female connector 37 pin D-SUB female connector 37 pin D-SUB female connector 37 pin
Connector 2 D-SUB male connector 37 pin Open terminals MINI-DIN male connector 8 pin D-SUB male connector 25 pin MINI-DIN male connector 6 pin
Further connections — — For power supply and external For power supply and external For power supply and external
signals signals signals
햲
Applicable CPU type — Factory automation periphery MELSEC FX family MELSEC AnS/QnAS and AnU/QnA MELSEC System Q
Length m 3.0 / 6.0 / 10.0 3.0 / 6.0 / 10.0 1.5 1.5 1.5
Order information Art. no. 191013 / 191014 / 191015 191016 / 191017 / 191018 191019 191020 191021
햲
For the connection of the PLC CPU a further cable is required (GT11H-C15R4-8P for MELSEC FX CPU or GT11H-C15R4-25P for MELSEC AnS/QnAS CPU or GT11H-C15R2-6P for MELSEC System Q CPU)
20 MITSUBISHI ELECTRIC
ACCESSORIES ///
왎 General Accessories
Stands
For the GT10/GT11 and GT15/GT16 terminals
stands for table-top installation are available. The
stands are useful for debugging the GOT screen
data, as they can set the GOT at a proper angle on
the table.
ACCESSORIES
GT10- GT10- GT11- GT11H- GT15- GT15- GT15- GT15- GT15- GT16- GT16- GT16- GT16-
Specifications
20PSCB 30PSCB 50PSCB 50PSC 50PSCB 60PSCB 70PSCB 80PSCB 90PSCB 60PSCB 70PSCB 80PSCB 90PSCB
Type of accessory Protective film sheets for the display surface
GT11H GT155x GT15 GT15 GT15 GT15 GT16 GT16 GT16 GT16
Use for operator terminal GT1020 GT1030 GT11 handy with 5.7" with 8.4" with 10.4" with 12.1" with 15" with 8.4" with 10.4" with 12.1" with 15"
GOTs display display display display display display display display display
Set of 5 5 5 5 5 5 5 5 5 5 5 5 5
Order information Art. no. 200501 206973 163645 191023 203501 166329 166333 166337 169476 221959 221958 221958 221370
Order information Art. no. 206836 206837 206838 206839 168155 168122 168156 168123 168154
Use for operator terminal GOT1000 with GOT1000 with GOT1000 with GOT1000 with GT15/GT16 All E1000 series models
5.7" display 8.4" and 10.4" display 12.1" display 15" display
Set of 1 1 1 1 1 1
Order information Art. no. 203502 166341 166342 218577 166345 217656
MITSUBISHI ELECTRIC 21
/// ACCESSORIES
왎 Communications Adapter
Specifications E1000-EM-Profibus/DP
Use for operator terminal E1000 series
Type Adapter
Application Profibus/DP Slave
GOT1000 models are available. GT15-DIO Optional interface for digital I/Os, 16 (max. 128) inputs, 16 outputs 209827
Further details on request. GT15-DIOR Digital I/O-card for GT15/GT16, 16 inputs, 16 outputs, negative common input 221953
GT01-RS4-M RS-485 Multi-drop master unit, 16 GOTs to one FX/Q PLC 225497
GT10-9PT5S GOT RS-485 adapter for GT10 QVGA and GT11 QVGA models, 9-pin DSUB 225498
GT10-50FMB GOT data transfer memory board for GT105x 218493
22 MITSUBISHI ELECTRIC
DIMENSIONS ///
13*
66 +1-0
Switchboard cutout
65
74
13*
113 27
105 +1-0
All dimensions in mm
145 4.5 6
10 84 10
DIMENSIONS
max. 80 65
84
76
10 84 10 21
29.5
25
13*
Switchboard cutout
All dimensions in mm
13*
137+-01
MITSUBISHI ELECTRIC 23
/// DIMENSIONS
왎 GT1040, GT1045
5
103 +1
–0
112
102
Switchboard cutout
139 41 130 +1
–0
All dimensions in mm
왎 GT1050, GT1055
6 RS232
RS422
121 +2
–0
135
6
* 7 * 7 S D Q H O F X W
120
R X W V L ] H V D P H D V ) * 2 7
Switchboard cutout
DIMENSIONS
USB
+2
164 56 153 –0
All dimensions in mm
왎 GT1150HS-QLBD / GT1155HS-QSBD
18 75
72
50 62
16
204
209
3.5
74
168
176
All dimensions in mm
24 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 GT1150-QLBD, GT1155-QSBD
164 164
120
10
120
135
135
10
120
164
5
120
Switchboard cutout
47
53
53
153 x 121
+2
–0
+2
–0
152
135
All dimensions in mm
6
왎 GT1550-QLBD, GT1555-QSBD, GT1555-QTBD, GT1555-VTBD
DIMENSIONS
167
110
10
Switchboard cutout
135
120
153 x 121
+2
–0
+2
–0
10
110
5
6
60
152
All dimensions in mm
MITSUBISHI ELECTRIC 25
/// DIMENSIONS
왎 GT1562-VNBA, GT1565-VTBA
GT1562-VNBD, GT1565-VTBD
241
175.5
10
190
175
Switchboard cutout
227 x 165
+2
–0
+2
–0
10
175.5
5
52
56
6
226
All dimensions in mm
6
왎 GT1572-VNBA, GT1575-VNBA, GT1575-VTBA, GT1575-STBA
DIMENSIONS
Switchboard cutout
289 x 200
+2
–0
+2
–0
All dimensions in mm
26 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 GT1585-STBA, GT1585-STBD
316
263
10
242
227
10
250
5
Switchboard cutout
52
56
302 x 228
6
+2 +2
–0 –0
301
All dimensions in mm
6
왎 GT1595-XTBA, GT1595-XTBD
DIMENSIONS
397
10
320
296
281
320
10
5
6
61
Switchboard cutout
383.5 x 282.5
+2
–0
+2
–0
382
All dimensions in mm
MITSUBISHI ELECTRIC 27
/// DIMENSIONS
241
175.5
10
190
175
Switchboard cutout
227 x 167
+2
–0
+2
–0
10
175.5
6
52
56
226
All dimensions in mm
6
DIMENSIONS
303
252
10
199
214
Switchboard cutout
289 x 200
+2
–0
+2
–0
222
10
49
56
+2
–0
+2
–0
288
All dimensions in mm
28 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 GT1685M-STBA, GT1685M-STBD
316
240
10
227
242
10
240
Switchboard cutout
302 x 228
+2 +2
6
–0 –0
52
56
All dimensions in mm
301
6
DIMENSIONS
왎 GT1695M-XTBA, GT1695M-XTBD
397
320
10
281
296
320
10
6
61
Switchboard cutout
383.5 x 282.5
+2
–0
+2
–0
10 382 10
All dimensions in mm
MITSUBISHI ELECTRIC 29
/// DIMENSIONS
왎 E1022
40.6
6 34.6 6.5 –9.0 mm
18.6 118 18.6 155.2
7.5 mm minimum thickness
9.2
155.2
136.1
9.9
All dimensions in mm
6
DIMENSIONS
왎 E1032
Switchboard cutout
166 × 149
COM2 COM1
RS232 RS422/485
19.3 163.4
202
9.8
Dip switches
147.4
USB
187
Ethernet
max. 7.5
56.9
62.9
All dimensions in mm
30 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 E1041 / E1043
Switchboard cutout
139 × 105
COM2 COM1
RS232 RS422/485
9.7 137.4
155.8
9
102.7
119
A
max. 7.2
56.8
A
62.8
All dimensions in mm
6
DIMENSIONS
왎 E1060 / E1062
Switchboard cutout
240 × 130
COM1
COM2 RS422/485
RS232
63.3
18.8 237.4 57.3
max. 7.5 275
17.7
CF memory
card
Battery
CF
Dip switches
128.5
168
USB
Ethernet
All dimensions in mm
MITSUBISHI ELECTRIC 31
/// DIMENSIONS
왎 E1061 / E1063
Switchboard cutout
180 ×130 mm
COM2 COM1
RS232 RS422/485
62.8
56.6
12.4 178.6 max. 7.5
201
10.9
CF memory
card
Battery
CFswitches
Dip
128.7
152
USB
Ethernet
6 All dimensions in mm
DIMENSIONS
왎 E1070
246±1
139±1
Switchboard cutout
244
27 285
20
134
177
A
24 V DC
max. 9
A
56
62
All dimensions in mm
32 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 E1100
343±1
208±1
Switchboard cutout
342
22 382
23
207
252
max. 9
A
58
24 V DC
A 64
All dimensions in mm 6
DIMENSIONS
왎 E1071
188±1
188,5±1
137.5±1
137,5±1
Switchboard cutout
187
21 219
6
154
136
max. 9
55
61
All dimensions in mm
MITSUBISHI ELECTRIC 33
/// DIMENSIONS
왎 E1101
264,5±1
206±1
Switchboard cutout
263
25
302
13
228
204
max. 9
58
64
6 All dimensions in mm
DIMENSIONS
왎 E1151
354
22
398
14
277
304
max. 9
60
66
Switchboard cutout
278.5±1 x 355.5±1 mm
All dimensions in mm
34 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 DT1151
56
22 354
50 398
14
304
277
All dimensions in mm
DIMENSIONS
왎 Keyboard Extension X-Key-16
Rubber gasket
included
200 28 5.5
15
Text strips
110
80
22
RS-485 13
15
RS-422
24 V DC
6 × Ø3,5
95 95 Max. 16
6
Min. 14
88±4
100
Switchboard cutout
2 186±1
All dimensions in mm
MITSUBISHI ELECTRIC 35
/// DIMENSIONS
왎 IPC-MC1121
380 46.75
343 6
14.75
127.5
116.5
255
273
300
83.5
127.5
9.5
325
Switchboard cutout
325 × 255
All dimensions in mm
6
DIMENSIONS
왎 IPC-MC1151
51.25
452 6
415 19.25
161.25
128.75
322.5
335
362
71.25
161.25
9.5
400
Switchboard cutout
400 × 322.5
All dimensions in mm
36 MITSUBISHI ELECTRIC
DIMENSIONS ///
왎 IPC-VP1151
152.75
449.4 34.25
422.4 6
372.4
277
354
327
311
406.4
Switchboard cutout
406.4 × 311
All dimensions in mm
DIMENSIONS
왎 IPC-VP1171
461 160
434 41.5
361 6
356
299
399
372
418
Switchboard cutout
418 × 356
All dimensions in mm
MITSUBISHI ELECTRIC 37
/// SOFTWARE AND PROGRAMMING
With the MELSOFT software family Mitsubishi Electric offers efficient software packages
helping to reduce programming and setup times to a high degree.
The MELSOFT software family provides instant access, direct communications, compatibil-
ity, and open exchange of variables.
MX4 HMI
MX4 HMI is a reduced version of MX4 SCADA. It includes many of the functions of
MX4 SCADA, but has been designed for standalone HMI applications.
The main features are:
앬 A large number of I/O points ranging from 100 to a maximum of 600, with the ability to
connect to three different types of drivers.
앬 It is a scalable solution that can be upgraded from a HMI to a SCADA solution and then
7 have additional upward connectivity to business systems.
앬 Basic functions like alarms, trend analysis and reports have been set-up and are
ready-to-use, saving you time and the expertise needed to program them.
SOFTWARE & PROGRAMMING
앬 The use of super genies enables you to save repetitive machinery processes, and repli-
cate the process by a click of a button. This saves time and the cost of skilled labour, al-
lowing a complex task to be performed much more simply.
38 MITSUBISHI ELECTRIC
SOFTWARE AND PROGRAMMING ///
GT Works
GTWorks is a wide-ranging programming and visualization control tool from Mitsubishi.
Included are the two main program parts GT SoftGOT1000 and GT Designer as well as a HMI
simulator and a converter for former projects. The software language is English, a German
version is also available. Please remark when ordering.
GT Designer
As part of GTWorks, GT Designer is a drawing program designed to create HMI screens for all
GOT series. A user-friendly Windows environment provides the user with a simple and
recognisable interface, reducing the time of their learning curve and the training costs asso-
ciated with it. The package consists of:
앬 An extensive picture and graphics library editor that enables you to modify the
graphics to meet your exact specifications.
앬 A tree format of the project gives you an overview of the structure of the project. This
gives you the opportunity to navigate through your project and add, delete or move
any programs or functions, creating a more logical flow to your menu structure.
7
A major benefit of GT SoftGOT1000 is that visualisation screens can be created independ-
ently of their final target platform, i. e. a hardware platform such as GOT1000 or a PC based
앬 Platform independent, screens created can be used for software-based HMIs or hard-
ware based GOT HMIs.
앬 Remote monitoring and operation by intranet LAN is possible.
앬 E-mail support for alarms
앬 Recording of historical Data in user-friendly formats
앬 Communication with MELSEC PLCs via serial communication, USB (to System Q port),
CC-Link IE PC card or Ethernet possible
앬 Windows and Microsoft programs can be accessed from within GT SoftGOT1000.
MITSUBISHI ELECTRIC 39
/// SOFTWARE AND PROGRAMMING
Programming HMI
왎 E-Designer
앬 Full support of the Windows editing functions (e.g. cut, copy, paste etc.)
앬 Extensive documentation and storage functions
앬 Different projects can be edited simultaneously.
앬 Multi-language support for up to 10 languages in the application
앬 The name list is compatible to GX IEC Developer.
앬 E-Designer is supported by MX-Change.
앬 Simulation mode for E1000 projects
40 MITSUBISHI ELECTRIC
MITSUBISHI ELECTRIC 41
Accessories E series operator terminals Interface Adapter and Cables for
Cables, general . . . . . . . . . . . . . . . . 18 DT1151 . . . . . . . . . . . . . . . . . . . . . 15 GT15/GT16
Cables for Handy-GOTs . . . . . . . . . . . 20 E1012 . . . . . . . . . . . . . . . . . . . . . . 14 CR01-R2/R4 SET. . . . . . . . . . . . . . . . 22
Cables for Third Party Manufacturers . . 20 E1022 . . . . . . . . . . . . . . . . . . . . . . 14 CR01-R4/R4 . . . . . . . . . . . . . . . . . . 22
CR01-R2/R4 SET. . . . . . . . . . . . . . . . 22 E1032 . . . . . . . . . . . . . . . . . . . . . . 14 GT01-RS4-M . . . . . . . . . . . . . . . . . . 22
CR01-R4/R4 . . . . . . . . . . . . . . . . . . 22 E1041 . . . . . . . . . . . . . . . . . . . . . . 14 GT10-50FMB. . . . . . . . . . . . . . . . . . 22
Interface converter . . . . . . . . . . . . . 22 E1043 . . . . . . . . . . . . . . . . . . . . . . 14 GT10-9PT5S . . . . . . . . . . . . . . . . . . 22
Keyboard extension . . . . . . . . . . . . . 21 E1060 . . . . . . . . . . . . . . . . . . . . . . 14 GT15-75ABUS(2)SL. . . . . . . . . . . . . . 17
Option cards. . . . . . . . . . . . . . . . . . 17 E1061 . . . . . . . . . . . . . . . . . . . . . . 14 GT15-75QBUS(2)SL . . . . . . . . . . . . . 17
Protective film sheets . . . . . . . . . . . . 21 E1062 . . . . . . . . . . . . . . . . . . . . . . 14 GT15-ABUS . . . . . . . . . . . . . . . . . . 17
Stands. . . . . . . . . . . . . . . . . . . . . . 21 E1063 . . . . . . . . . . . . . . . . . . . . . . 14 GT15-ABUS2 . . . . . . . . . . . . . . . . . . 17
Video Interfaces . . . . . . . . . . . . . . . 17 E1070 . . . . . . . . . . . . . . . . . . . . . . 15 GT15-DIO. . . . . . . . . . . . . . . . . . . . 22
E1070 Pro+. . . . . . . . . . . . . . . . . . . 15 GT15-DIOR . . . . . . . . . . . . . . . . . . . 22
Cables E1071 . . . . . . . . . . . . . . . . . . . . . . 15 GT15-J61BT13 . . . . . . . . . . . . . . . . . 17
CAB11 . . . . . . . . . . . . . . . . . . . . . . 20 GT15-J71BR13. . . . . . . . . . . . . . . . . 17
E1071 Pro+. . . . . . . . . . . . . . . . . . . 15
CAB17 . . . . . . . . . . . . . . . . . . . . . . 19 GT15-J71E71-100. . . . . . . . . . . . . . . 17
E1100 . . . . . . . . . . . . . . . . . . . . . . 15
CAB18 . . . . . . . . . . . . . . . . . . . . . . 19 GT15-J71GP23-SX . . . . . . . . . . . . . . 17
E1100 Pro+. . . . . . . . . . . . . . . . . . . 15
CAB19 . . . . . . . . . . . . . . . . . . . . . . 19 GT15-J71LP23-25. . . . . . . . . . . . . . . 17
E1101 . . . . . . . . . . . . . . . . . . . . . . 15
CAB30 . . . . . . . . . . . . . . . . . . . . . . 19 GT15-MESB48M. . . . . . . . . . . . . . . . 17
E1101 Pro+. . . . . . . . . . . . . . . . . . . 15
CAB34/3 . . . . . . . . . . . . . . . . . . . . 19 GT15-PRN . . . . . . . . . . . . . . . . . . . 17
E1151 . . . . . . . . . . . . . . . . . . . . . . 15
CAB36 . . . . . . . . . . . . . . . . . . . . . . 19 GT15-QBUS . . . . . . . . . . . . . . . . . . 17
E1151 Pro+. . . . . . . . . . . . . . . . . . . 15
CAB8 . . . . . . . . . . . . . . . . . . . . . . 20 GT15-QBUS2. . . . . . . . . . . . . . . . . . 17
Introduction . . . . . . . . . . . . . . . . . . 12
F9GT-HCAB-3M . . . . . . . . . . . . . . . . 20 GT15-RS2-9P. . . . . . . . . . . . . . . . . . 17
FA-LTBGTR4CBL05 . . . . . . . . . . . . . . 19 GOT series operator terminals GT15-RS2T4-25P . . . . . . . . . . . . . . . 17
FA-LTBGTR4CBL10 . . . . . . . . . . . . . . 19 GT1020 . . . . . . . . . . . . . . . . . . . . . .8 GT15-RS2T4-9P . . . . . . . . . . . . . . . . 17
FA-LTBGTR4CBL20 . . . . . . . . . . . . . . 19 GT1030 . . . . . . . . . . . . . . . . . . . . . .8 GT15-RS4-9S. . . . . . . . . . . . . . . . . . 17
GT01-C30R2-6P . . . . . . . . . . . . . . . . 18 GT1040 . . . . . . . . . . . . . . . . . . . . . .8 GT15-RS4-TS . . . . . . . . . . . . . . . . . . 17
GT01-C30R4-25P . . . . . . . . . . . . . . . 18 GT1045 . . . . . . . . . . . . . . . . . . . . . .8 GT16M-MESB . . . . . . . . . . . . . . . . . 17
GT01-C30R4-8P . . . . . . . . . . . . . . . . 18 GT1050 . . . . . . . . . . . . . . . . . . . . . .8
GT09-C20USB-5P . . . . . . . . . . . . . . . 18 GT1055 . . . . . . . . . . . . . . . . . . . . . .8 Option Cards for GT15
GT10-C30R2-6P . . . . . . . . . . . . . . . . 18 GT1150 . . . . . . . . . . . . . . . . . . . . . .9 GT15-FNB . . . . . . . . . . . . . . . . . . . 17
GT10-C30R4-8P . . . . . . . . . . . . . . . . 18 GT1150HS . . . . . . . . . . . . . . . . . . . .9 GT15-MESB48M. . . . . . . . . . . . . . . . 17
GT10-RS2TUSB-5S . . . . . . . . . . . . . . 18 GT1155 . . . . . . . . . . . . . . . . . . . . . .9 GT15-QFNB . . . . . . . . . . . . . . . . . . 17
GT11H-C100 . . . . . . . . . . . . . . . . . . 20 GT1155HS . . . . . . . . . . . . . . . . . . . .9 GT15-QFNB16M . . . . . . . . . . . . . . . 17
GT11H-C100-37P . . . . . . . . . . . . . . . 20 GT1550 . . . . . . . . . . . . . . . . . . . . . .9 GT15-QFNB32M . . . . . . . . . . . . . . . 17
GT11H-C15R2-6P . . . . . . . . . . . . . . . 20 GT1555 . . . . . . . . . . . . . . . . . . . . . .9 GT15-QFNB48M . . . . . . . . . . . . . . . 17
GT11H-C15R4-25P . . . . . . . . . . . . . . 20 GT1562 . . . . . . . . . . . . . . . . . . . . . 10
Overviews
GT11H-C15R4-8P . . . . . . . . . . . . . . . 20 GT1565 . . . . . . . . . . . . . . . . . . . . . 10
Cables . . . . . . . . . . . . . . . . . . . . . . 18
GT11H-C30. . . . . . . . . . . . . . . . . . . 20 GT1572 . . . . . . . . . . . . . . . . . . . . . 10
E series . . . . . . . . . . . . . . . . . . . . . 12
GT11H-C30-37P. . . . . . . . . . . . . . . . 20 GT1575 . . . . . . . . . . . . . . . . . . . . . 10
GOT series . . . . . . . . . . . . . . . . . . . .6
GT11H-C60. . . . . . . . . . . . . . . . . . . 20 GT1575V . . . . . . . . . . . . . . . . . . . . 10
Networks. . . . . . . . . . . . . . . . . . . . .5
GT11H-C60-37P. . . . . . . . . . . . . . . . 20 GT1585 . . . . . . . . . . . . . . . . . . . . . 10
GT15-A1SC30B . . . . . . . . . . . . . . . . 18 GT1585V . . . . . . . . . . . . . . . . . . . . 10 Software
GT15-AC30B . . . . . . . . . . . . . . . . . . 18 GT1595 . . . . . . . . . . . . . . . . . . . . . 10 E-Designer . . . . . . . . . . . . . . . . . . . 40
GT15-QC30B. . . . . . . . . . . . . . . . . . 18 GT1665M . . . . . . . . . . . . . . . . . . . . 11 GT Works2 . . . . . . . . . . . . . . . . . . . 39
GT16-C20R4-9S . . . . . . . . . . . . . . . . 19 GT1675M . . . . . . . . . . . . . . . . . . . . 11 MX4 HMI . . . . . . . . . . . . . . . . . . . . 38
Overview . . . . . . . . . . . . . . . . . . . . 18 GT1685M . . . . . . . . . . . . . . . . . . . . 11
GT1695M . . . . . . . . . . . . . . . . . . . . 11 Stands
Communications adapter Introduction. . . . . . . . . . . . . . . . . . .6 GT05-50STAND . . . . . . . . . . . . . . . . 21
E1000-EM-Profibus/DP . . . . . . . . . . . 22 GT15-70STAND . . . . . . . . . . . . . . . . 21
Industrial PCs GT15-80STAND . . . . . . . . . . . . . . . . 21
Dimensions Dimensions . . . . . . . . . . . . . . . . . . 36 GT15-90STAND . . . . . . . . . . . . . . . . 21
E1000 series operator terminals . . . . . 30
Introduction . . . . . . . . . . . . . . . . . . 16
GOT series opeartor terminals . . . . . . 23 Video Interfaces for GT15/GT16
IPC-MC1121 . . . . . . . . . . . . . . . . . . 16
Industrial PCs . . . . . . . . . . . . . . . . . 36 GT15V-75R1 . . . . . . . . . . . . . . . . . . 17
IPC-MC1151 . . . . . . . . . . . . . . . . . . 16
IPC-VP1151 . . . . . . . . . . . . . . . . . . 16 GT15V-75ROUT . . . . . . . . . . . . . . . . 17
IPC-VP1171 . . . . . . . . . . . . . . . . . . 16 GT15V-75V4 . . . . . . . . . . . . . . . . . . 17
GT15V-75V4R1 . . . . . . . . . . . . . . . . 17
GT16M-MMR . . . . . . . . . . . . . . . . . 17
GT16M-R2 . . . . . . . . . . . . . . . . . . . 17
GT16M-ROUT . . . . . . . . . . . . . . . . . 17
GT16M-V4 . . . . . . . . . . . . . . . . . . . 17
GT16M-V4R1 . . . . . . . . . . . . . . . . . 17
42 MITSUBISHI ELECTRIC
Visualisation and productivity /// Visualisation and productivity /// Automation solutions /// Automation solutions /// Automation solutions /// Automation solutions /// Automation
Visualisation A world of
and productivity automation solutions
In fact some HMIs have the ability to report Robots
Enterprise PC Servo amplifiers
(MES/ERP/SCADA) errors remotely, even contacting the main-
tenance team before the line operators are Motion control and servos
aware there is a problem. The potential of
LV circuit protection Inverters
visualisation tools to improve process
“uptime” is enormous.
Remote I/Os
Micro PLCs
14 15
MITSUBISHI
ELECTRIC
Global partner. Local friend. FACTORY AUTOMATION
HMI
Visualisation Tools
Powerful Communication
Simple Words and Pictures
System and Process Visualisation /// Touch Screen and Key Operation ///
MITSUBISHI Powerful Maintenance Tools /// PLC Program Display /// Direct MES
ELECTRIC Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Gothaer Straße 8 /// D-40880 Ratingen /// Germany
FACTORY AUTOMATION Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// info@mitsubishi-automation.com /// www.mitsubishi-automation.com
Specifications subject to change /// Art. no. 207075-C /// 10.2009 Integration /// HMIs /// GOTs /// IPCs /// SCADA /// Software ///
All trademarks and copyrights acknowledged.