Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
TMD 0001 CAD Manual- All sections (except section 5 – Electrical operating diagrams) are
legacy documents and shall be used for reference purposes only. ASA standard
T MU MD 00006 ST Engineering Drawings and CAD Requirements, Version 1.0 supersedes this
document from 01 March 2016.
Authorisation:
Technical content Checked and Interdisciplinary Authorised for
prepared by approved by coordination release
checked by
Signature
Date
Name Harpreet Singh Jagath Peiris John Paff Graham Bradshaw
Position CAD Specialist Manager Network A/Chief Engineer Rail Director
Standards Network Standards
and Services
Engineering Manual
TMD 0001
SIGNAL – SECTION 6
Version 1.6
Disclaimer
This document was prepared for use on the RailCorp Network only.
RailCorp makes no warranties, express or implied, that compliance with the contents of this document shall be
sufficient to ensure safe systems or work or operation. It is the document user’s sole responsibility to ensure that the
copy of the document it is viewing is the current version of the document as in use by RailCorp.
RailCorp accepts no liability whatsoever in relation to the use of this document by any party, and RailCorp excludes
any liability which arises in any manner by the use of this document.
Copyright
The information in this document is protected by Copyright and no part of this document may be reproduced, altered,
stored or transmitted by any person without the prior consent of RailCorp.
Document control
Version Date Summary of change
NOTE TO USER
© RailCorp Page 2 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Contents
6.1.3 Definitions...................................................................................................6
6.2.1 General.......................................................................................................7
Level .........................................................................................................10
6.3.1 General.....................................................................................................10
6.4.1 General.....................................................................................................14
6.4.6 Text...........................................................................................................19
6.5.1 General.....................................................................................................22
6.6.2 Size...........................................................................................................24
6.7.1 Scale.........................................................................................................24
© RailCorp Page 3 of 63
6.8
Other Drawings........................................................................................................25
© RailCorp Page 4 of 63
6.1 Introduction
6.1.1 Scope
This section of the CADD Manual is intended to address the production of CAD drawings
associated with signalling works and assist to:
If, in special cases or for particular clients, it becomes necessary to deviate from these
practices, then the Signal Design Manager must first give approval. Any proposed
permanent change or alternative to these procedures must be circulated to Signal Design
Section staff for their comment and subsequent agreement. Changes shall be
incorporated in this Manual.
This section of the Manual also contains information and advice on the detailing of
drawings. The use of this information should lead to the best and most economic solution
of drafting problems, (resulting in savings in time and effort) even when the drafting
officer is not fully familiar with the particular work.
This policy will be strictly enforced. The CAD Team will be going around to each
individual to explain the structure and help sort out files in their H: Drive.
Specified Areas
Only the R: drive will be used. There are specific folders for each type of document.
These are:
© RailCorp Page 5 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
• Signalling/Track Plans
• Track Insulation Plans
• Train Order Working (not everyone will need to use this)
• Proposals and Misc. (used for work which doesn’t fall into any other specific folder)
Within these folders there will be a folder for that specific area eg> Signalling
Plans\Sutherland – Cronulla or Drivers Diagrams\Dubbo. This system is the same as
used for Circuit Books.
Then with each folder there is a sub-folder specific to each type of task:
Designer - This folder is used to do any work for the design process and can contain any
number of other folders. It will be electronically secured for the user, so he/she will be the
only one who can alter the drawing and has total control of how this area is used. Once
the design is done, it can be used to store the drawings until the updates are ready to
commence. No work shall be done to this folder without consulting the original owner.
The CAD controller will always notify the designer about any changes via e-mail.
Maint_Update – This folder is used when updating the drawings to COC’s for
maintenance updating.
When all files have been updated, issued, new CDs burnt and masters returned to the
planroom, all files should be removed except any outstanding design work (and PDF/TIF
files). The updating team will have to liaise with the designer to ensure that all parties
know that this is happening.
Please be patient. We want this system to be flexible and as user friendly as possible, it
is being set up to aid everyone. I know there will be problems, if you have any, please do
not hesitate to contact any of us.
6.1.3 Definitions
© RailCorp Page 6 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
6.2.1 General
• All documentation and drawings including those submitted for review, shall be laid
out in a clear and logical fashion and shall be such as to facilitate understanding,
checking, construction and maintenance.
• Current digitised Signalling Plans, Track Insulation Plans are in MicroStation
software and Circuit Diagrams in AutoCAD software. New and amended plans,
including Signalling Plans, Track Insulation Plans, Detailed Site Survey Drawings,
Drivers Diagrams, Weekly Notice Insertions, Equipment Housing Plans, Level
Crossing Plans plus other plans and drawings associated with signalling projects
shall be prepared using MicroStation v8.1 or higher. New and amended circuit
diagrams shall be prepared using AutoCAD LT2000 or AutoCAD 2000 or later
version.
• Final digitised drawings shall be provided on write once Compact Discs.
• Documentation and drawings shall be prepared for A4 or A3 size paper and roll
plans. Roll plans shall be divided into manageable and logical lengths and with
height of 450mm wide (max.). A2 and A1 size paper may be allowed for detailed
mechanical and structural drawings.
• Geographically oriented drawings shall have the Sydney direction at the left hand
side.
• Each design drawing including amended drawings shall be distinctively and
uniquely identified as shall each controlled copy of a drawing.
• Each drawing shall include the names of the designer, checker and approver.
Details shall be provided for each amendment/issue of the drawing.
© RailCorp Page 7 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Where several CDs are required for a circuit book the CDs shall be numbered as part of
the set. By way of example, where 10 CDs are required for a circuit book the Compact
Disc number shall be in the following form:
In addition to the original copy a Backup copy of each drawing compact disc shall be
provided. These backup copy CDs shall have detailed labels as provided on the original
copy drawing compact discs. Additionally, the Backup copy shall carry the name
"BACKUP COPY DRAWINGS".
e.g. C0750A25.DWG
Indicator Diagram:
F Circuit Book Nos. 0 or 1 010
000 - 999 0 = As Built Fixed
1 = Work in Progress
e.g. F0610010.DGN
© RailCorp Page 8 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Drivers Diagram:
Mechanical Drawing:
Figure 1
RailCorp name:
Drawing Type: (eg Signalling Plan, Track Insulation Plan, Circuit Diagram,
Signalling Arrangements)
Drawing Number:
Version Date:
© RailCorp Page 9 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
For each amendment to the drawing the following details shall be included;
M:\Rail\ustn_wsV8\RC_Modules\Signals\cell
M:\Rail\ustn_wsV8\RC_Modules\Signals\dgnlib\SD_Level.dgnlib.
6.3.1 General
Signalling Plans shall include details in accordance with Specification SPG 0703 and
cover the whole of the Works including interface details at the Contract limits. Plans shall
extend sufficiently at Contract limits to detail approach locking points and overlap
clearance points for all signals included in the Works.
6.3.2 Overlapping
Overlapping of Signalling Plans shall be kept to a minimum. However individual plans
shall extend sufficiently to detail clearance points for all controlled signals included in the
plan. Each end of the plan shall include the name and drawing number of the adjoining
plan.
© RailCorp Page 10 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
6.3.4 Centreline
The centreline of all symbols for equipment and structures shall be as longitudinally
correct to scale as feasible and laterally correct relative to the track centre lines and
laterally spaced for legibility.
a) The scale for all plans on screen shall be 1:1000, multi-scaling for plotted
drawings may be presented for approval.
c) A Signalling Plan shows the track layout for the area involved on a single line
basis ie. each pair of rails shown as a single line. The Signalling Plans are
drawn such that Sydney is on the left of the plan, the lines are drawn straight.
Curve and gradient details are drawn above the track layout. The curve
diagram illustrates where they occur in the track, the curve radius shown in
metres and the gradient details shown relative to the track and illustrate the
differing gradients by the ratio of the rise or fall. Eg. 1 in 50 etc.
Symbols used to represent the various details on the Signalling Plan shall be in
accordance with the symbols included in Appendix D.
e) The area between 12cm and 14cm (or the Co-ordinate y = 0.012 and y = 0.014)
above the coordinate where y = 0 shall be kept clear for use others for scaling
purposes.
© RailCorp Page 11 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 12 of 63
© RailCorp Page 13 of 63
6.4.1 General
Signalling circuits shall include details in accordance with Specification SPG 0703.
© RailCorp Page 14 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 15 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 16 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Telephones/Communications W1 - W9
Spare W10 - 99
Notes:
Where multiple level crossings are within the same circuit book circuits are to be grouped
by crossings.
© RailCorp Page 17 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Circuit drawings shall include layers, linework, text, plus system variables and support
operating variables preset to values listed in the tables below.
If other layers, colours and/or linestyles for temporary use are utilised, then they shall be
removed from the drawing before the final discs are submitted.
6.4.5 Linework
PLINE shall be used for line-work.
0mm and 0.5mm are the only allowable widths.
© RailCorp Page 18 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
6.4.6 Text
Text can be placed in the drawing using either the TEXT or DTEXT command using the
necessary justification.
The A3 border block is a master sheet block. A library of standard master sheet blocks
already exists. eg. 'Q' type relay analysis sheet, cable analysis sheet, fuse and terminal
list sheets, etc...
Master sheet blocks shall be inserted in the drawing at (0,0), X scale factor = 1, Y scale
factor = 1 and rotation angle = 0 degrees.
NB: Master sheet blocks listed are the only acceptable blocks that may be placed in
any circuit drawing for the purpose of a MASTER SHEET.
Where a master sheet that is not listed needs to be created then full details of the sheet
shall be referred for approval.
BLOCKS shall be placed on a 5mm GRID in the circuit drawing and connected to other
BLOCKS using PLINES.
Where a circuit element that is not listed needs to be created then full details of the
element shall be referred for approval.
Maintenance New/Removed
Drawing Drawing
---- Pen ---- ---- Pen ---
© RailCorp Page 19 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Each sheet or part of an extended sheet shall be plotted on 80 gsm (420mm x 297mm)
A3 media.
© RailCorp Page 20 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
<CATEGORY> - 1 character
Identifies the type of information stored in the
file.
CIRCUIT DRAWINGS are represented by the
letter "C".
<CB NUMBER> - 3 character
Identifies the CIRCUIT BOOK by circuit book
number.
SHALL BE 3 characters. ie:CB:1 = 001
<SIGNALLING STANDARD - Standard book identified by : STD ie:CSTD
DRAWING> DRAWING>
<SHEET NUMBER> - 4 characters
Identifies the SHEET whose data is stored in
the file. SHALL BE 4 characters. ie:sheet A26
= A026
[FILE SEPARATER] - is always the 9th character. This character is
always a "." (period).
Its purpose is to separate the FILE NAME from
the FILENAME EXTENSION
015 = CB number
© RailCorp Page 21 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
FILENAME FORMAT
C015A027.DWG
Version Number
The Circuit book number shall be in the form - CB No: 27, CB No: 143, etc.
6.5.1 General
a) Detailed Site Survey Drawings shall include details in accordance with
Specification SPG 0703. The content of Detailed Site Survey Drawings (DSS
Drawings) shall be kept to manageable areas and shall be numbered to form a
logical pattern. An overall index shall be provided.
b) The software version of the detailed site survey drawings shall be drawn at 1:1
scale and plotted to the required scale on A3 paper. All text and symbols are to
be legible when plotted on A4 paper. In very complex areas, the vertical scale
may be abandoned but all vertical dimensions must be shown to the relevant
trackside equipment. One hundred-metre sections plotted to a scale of 1:250 is
preferred in most cases but scales of 1:200 and 1:500 are permissible.
c) Where mapping files are available these are to be used as a basis for detailed
site surveys.
e) DSS drawings shall be fully dimensioned to show the location of every kilometre
and half kilometre post, the final cable routes, underline crossings (ULX's),
station buildings, signal boxes, relay rooms, housings, location cases and
lineside equipment with reference to the running face of the nearest railway line
and, where applicable, existing buildings which are to remain and/or overhead
wiring structures.
© RailCorp Page 22 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
f) Detailed Site Survey Drawings shall also show those existing items which affect
the construction of the new works, and which are subsequently to be removed.
After removal they shall be deleted from the as built drawings.
Layer Colour
Name
L0 White Page Set Set of the border, Title Lines and the Legend
L1 Yellow Km Ref References in kilometres
L2 Cyan Cable Rt Cable Route with all the trackside equipment
L3 Blue Environ Environment: buildings, roads, stairways,
pathways
L4 Red Deminsio Dimensions
L5 Green Text Labels and descriptions
L5 Green Text Labels and descriptions
L6 Brown Others
L7 Magenta Existing trackside equipment, buildings and cable routes etc.
that become redundant
c) Drawing sheet sizes shall be A3 with a border layout as per the Signalling
Circuit Design Standards SC 00140000 SP. The sheet (MBORDA4) shall be
396mm (X direction) and 273mm (Y direction).
6.6.1 Format
Current drawings are in MicroStation and AutoCAD 2000. Unless otherwise approved
new and amended drawings shall be prepared using AutoCAD LT2000 or AutoCAD 2000
or later.
© RailCorp Page 23 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Note: * Weights not applicable if True Type text fonts, such as Arial, are used.
6.6.2 Size
Shall conform to suitable reduction for publication in Weekly Notice. Standard sized
sheets are available and shall be used. CAD generated diagrams shall be programmed to
conform to these sizes. All drawing content shall be drawn as size permitted in proportion
to drawing.
6.6.3 Reduction
Signal symbols, lettering size, line thickness and gaps between lines (particularly in
congested areas) shall be large enough to be clearly legible when reduced for
publication. (Diagram may be photocopy-reduced to appropriate size for verification).
RAC of N.S.W.
WYONG
SIGNALLING ARRANGEMENT
6.7.1 Scale
Track Insulation Plans shall be straight line plans drawn to longitudinal scales of 1:500 for
interlocking areas and 1:1000 for other areas.
© RailCorp Page 24 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 25 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
N:\Groups\Sig_des\COMMON\GRAPHICS.
SD_mstplan.cel
CELL NAME CELL DESCRIPTION
LINE
2LGHT2
SIG6..
NTCBRD
CUPBRD
FRAME1
XSIGN.
TRNSFM
POINTS
CLMLCK
CHOKE.
MUTXRX
MLTCRS
SGLPT.
DBLPTS
ISJNT4
ISJNT1
ISJNT2
CIRCLE
XOVER2
SCLBAR
XOVER4
BOLTLK
S250
S500
S1000
S2000
S5000
S10000
S20000
XOVER5
SYMB15
LNMARK
RELSW2
POST..
INDR13
INDR15
INDR14
INDR9.
POST1.
SIGBOX
ISJNT5
CTTRK1
PLUS
BALVER
© RailCorp Page 26 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
CONTAC
SCSYM
SIG3..
SIG4..
SIG5..
SOLAR
REYRL
ISJNT6
PWRFD3
PWRFD4
BCROSS
SMCRSS
BANNER
CUTTRK
CLRPST
XOVER1
TUMURX
EARTH1
EARTH2
ISLBND
STPBRD
DSTBRD
STDFRM
FLAG
XOVRIS
ST87
NOLGHT
TRSFM2
CB1...
TRSFM1
EOC1..
EOC...
MTRMGR
VARSB1
IDCTBD
MAINBD
VARSBD
VARBD.
IDPBD.
CBBD..
IVAPBD
THYRS1
THYRS2
SPDBRD
MAKER1
SHUNT1
INDR16
INDR12
CLSUP1
RELSW3
PHONE2
MARKE0
1LGHT1
2LGHT1
3LGHT1
© RailCorp Page 27 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
2LGHT3
3LGHT2
3LIGHT
5LIGHT
POINT2
GNSIG1
GNSIG2
GNSIG3
GNSIG4
GNSIG5
GNSIG6
GNSIG7
4LIGHT
5LGHT1
SIG82.
SIG444
SIG1..
SIG7
SIG2..
SIG8..
SIG81.
1LGHT2
RABSIG
WRNGRD
BELL..
XING1.
XING2.
XING3.
PHONE1
RELSW1
TSTOP.
LOCK..
DERAIL
REYRL1
ARESTR
INDR11
DCFEED
1LGHT3
JOIN BLOCK JOIN FOR TIP
BOND1 BOND FOR TIP
DOT01 DOT01 FOR TIP
TEXT04 TEXT04 FOR TIP
TEXT05 TEXT05 FOR TIP
CONN CONNECT FOR TIP
TU001 TU001 FOR TIP
TU002 TU002 FOR TIP
TU004 TU004 FOR TIP
ARR01 ARR01 FOR TIP
TU005 TU005 FOR TIP
ARR02 ARR02 FOR TIP
TEXT06 TEXT06 FOR TIP
TEXT07 TEXT07 FOR TIP
TEXT08 TEXT08 FOR TIP
ACFD01 ACFEED FOR TIP
FUSE01 FUSE01 FOR TIP
© RailCorp Page 28 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 29 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
title.cel
CELL NAME CELL DESCRIPTION
© RailCorp Page 30 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
OverrideWeight
ElementAccess
ByLevelWeight
OverrideColor
GlobalDisplay
OverrideStyle
ByLevelColor
ByLevelStyle
Description
Number
Name
Plot
C-TRAK-NORM 4000 Track Normal Linework 0 0 0 6 0 2
C-TRAK-RDNT 4001 Track Linework New 0 0 0 3 0 1
C-TRAK-DASH 4002 Track Linework Removed 0 0 0 3 0 0
(Dashed)
C-TRAK-CURV 4003 Track Curve 0 0 0 3 0 0
C-TRAK-GRAD 4004 Track Gradient 0 0 0 3 0 0
C-TRAK-NOTE 4005 Track Name 0 0 0 3 0 0
C-TRAK-LABL 4006 Track Length 0 0 0 3 0 0
C-TRAK-CELL 4007 Track Signal Symbology 0 0 0 4 0 0
SGNL
C-TRAK-CELL 4008 Track Structural Symbology 0 0 0 5 0 1
STRU
C-TRAK-ROUT 4009 Track Route Information 0 0 0 5 0 2
C-STRU-GANT 4010 Structures Gantries 0 0 0 3 0 0
C-STRU-PLAT 4011 Structures Platform Linework 0 0 0 3 0 0
C-STRU-BRIG 4012 Structures Bridge Linework 0 0 0 3 0 0
C-STRU-STRT 4013 Structures Street Linework 0 0 0 3 0 0
C-SGNL-CELL 4014 Signal Symbol 0 0 0 3 0 0
SYMB
C-SGNL-TEXT 4015 Signal Text 0 0 0 0 0 0
C-SGNL-AREA 4016 Signal Location Boundary 0 0 0 3 0 0
C-POWR-CELL 4017 Power Supply Diagram Cells 0 0 0 5 0 1
C-POWR-LINE 4018 Power Supply Diagram Positive 0 0 0 5 0 1
PSTV
C-POWR-LINE 4019 Power Supply Diagram 0 0 0 5 0 1
NGTV Negative
C-POWR-TEXT 4020 Power Supply Diagram General 0 0 0 5 0 1
Text
C-POWR-LABL 4021 Power Supply Diagram 0 0 0 5 0 1
Labelling
C-SIGN-CELL 4022 Sign Speed Posting 0 0 0 3 0 0
C-PANL-TRAK 4023 Panel Track Linework 0 0 0 3 0 2
C-PANL-GRID 4024 Panel Grid 0 0 0 2 0 0
C-PANL-LGHT 4025 Panel Lights 0 0 0 2 0 0
C-PANL-CTRL 4026 Panel Controls Buttons 0 0 0 2 0 0
BTTN
C-PANL-CTRL 4027 Panel Controls Lights 0 0 0 2 0 0
LGHT
C-PANL-LMRK 4028 Panel Frames and Platforms 0 0 0 2 0 0
C-PANL-TEXT 4029 Panel Text 0 0 0 2 0 0
C-INSU-BOND 4030 Insulation Bonding 0 0 0 2 0 0
C-INSU-DOTT 4031 Insulation Positive 0 0 0 2 0 0
C-INSU-FILL 4032 Insulation Negative 0 0 0 2 0 0
C-INSU-BLKJ 4033 Insulation Blockjoints 0 0 0 2 0 0
C-INSU-STAN 4034 Insulation Stanchions and 0 0 0 2 0 0
Spark Gaps
C-INSU-SIGS 4035 Insulation Cell and Text 0 0 0 2 0 0
C-INSU-FEED 4036 Insulation Feed and Relay 0 0 0 2 0 0
Information
© RailCorp Page 31 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
OverrideWeight
ElementAccess
ByLevelWeight
OverrideColor
GlobalDisplay
OverrideStyle
ByLevelColor
ByLevelStyle
Description
Number
Name
Plot
C-WORK-NEW 4037 New Work 0 0 0 4 0 0
C-WORK-RMOV 4038 Work to be Removed 0 0 0 2 0 0
C-LOCK-DPLX 4039 Duplex Locks 0 0 0 2 0 0
C-LOCK-BARS 4040 Locking Bars and Rods 0 0 0 2 0 0
C-LOCK-ELEC 4041 Electric Locks 0 0 0 2 0 0
C-LOCK-CTCH 4042 Catch Rods and Lights 0 0 0 2 0 0
C-LOCK-KEYS 4043 Locking Keys 0 0 0 2 0 0
C-KLMG 4044 Kilometrage Cells and Text 0 0 0 3 0 0
C-DIMS-PRIM 4045 Dimensions Primary 0 0 0 2 0 0
C-DIMS-SECD 4046 Dimensions Secondary 0 0 0 2 0 0
C-DIMS-GNRL 4047 Dimensions General 0 0 0 2 0 0
C-DIMS-MISC 4048 Dimensions Miscellaneous 0 0 0 2 0 0
C-HIDD-LINE-OVER 4049 Hidden Lines Over 0 3 0 3 3 0
C-HIDD-LINE-UNDR 4050 Hidden Lines Underneath 0 2 0 3 2 0
C-TEXT-LABL-MINR 4051 Minor Labelling 0 0 0 2 0 2
C-TEXT-LABL-MAJR 4052 Major Labelling 0 0 0 2 0 3
C-TEXT-TABL 4053 All Drawing Tables 0 0 0 2 0 1
C-TEXT-SCHD 4054 All Drawing Schedules 0 0 0 2 0 1
C-TEXT-175 4055 General Text 1.75 0 0 0 2 0 0
C-TEXT-25 4056 General Text 2.5 0 0 0 2 0 0
C-TEXT-35 4057 General Text 3.5 0 0 0 2 0 1
C-TEXT-50 4058 General Text 5.0 0 0 0 2 0 1
C-TEXT-70 4059 General Text 7.0 0 0 0 2 0 1
© RailCorp Page 32 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZZARROW 13O 1 1 1 X 1 1 1 ARROW (used for
tap-off points in
circuits)
ZZBELLB 19A 1 1 1 X X 1 X BELL Block (single
stroke)
ZZBELLT 19B 1 1 1 X X 1 X BELL Trembling
ZZBICNC 19N 1 1 1 X X 1 X Block Instrument
stick Relay
Normally closed
ZZBIR 19M 1 1 1 X X 1 X Block Instrument
stick Relay
ZZBMC 13H 1 1 1 X X 1 1 Battery Multiple
Cell
ZZBSC 13G 1 1 1 X X 1 1 Battery Single Cell
ZZBSIGC 6G 1 1 1 X X 1 X Banner Signal
Contact
ZZBUSPS 13I 1 1 1 X X 1 X Bus Power Supply
ZZBUSTS1 13E 1 X 1 X X 1 1 BUS Terminal
Supply 1 only
ZZBUSTS2 13F 1 X 1 X X 1 1 BUS Terminal
Supply 2 only
ZZCAC 4L 1 1 1 X X 1 X Contactor A.C.
ZZCACMI 4J 1 1 1 X X 1 X Contactor A.C.
Mechanically
Interlocked
ZZCAP 20A 1 1 1 X X 1 1 CAPacitor
ZCAPE 20B 1 1 1 X X 1 1 CAPacitor
Electrytic
ZCAPVSP 20C 1 1 1 X X 1 1 CAPacitor Voltage
Surge Protection
ZCBCC 2E 1 1 1 X X 1 X Contactor Back
Contact Closed
ZCBCO 2D 1 1 1 X X 1 X Contactor Back
ContactOpened
ZCCLUT 100 1 1 1 X X 1 X Contact CLUTch
ZCCRK1 10R 1 1 1 X X 1 X Contact CRanK
type 1 (points
machine)
ZCDC 4K 1 1 1 X X 1 X Contactor D.C.
ZCDLNO 10Q 1 1 1 X X 1 X Contact Duplex
Lock Normally
Open
ZCFCC 2A 1 1 1 X X 1 X Contactor Front
ContactClosed
ZCFCO 2B 1 1 1 X X 1 X Contactor Front
Contact Open
ZCOIL 12A 1 X 1 1 1 1 1 COIL (air core)
© RailCorp Page 33 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZCOILC1 3L 1 1 1 X X 1 X X COIL Clutch
type 1
ZCOILH1 3R 1 1 1 X X 1 X X COIL pick-up &
Holdclear type 1
ZCOILIC 12B 1 X 1 1 1 1 1 COIL (Iron Core)
ZCOILT 12C 1 X 1 X X 1 1 COIL Transformer
ZCOM 13B 1 1 1 X X 1 X COMmon terminal
ZDIMCOIL 12G 1 1 1 X X 1 X DIMming COIL
ZDIODE 20P 1 1 1 X X 1 1 DIODE
ZDIODER 20R 1 1 1 X X 1 X DIODE bridge
Rectifier
ZDIODEZ 20Q 1 1 1 X X 1 1 DIODE Zener
ZEARTH 20O 1 1 1 X 1 1 1 EARTH
connection
ZEDCSCO 8C 1 1 1 X X 1 X Electrical Detector
Contact Sw.only
Change Over
ZEDCSN 8A 1 1 1 X X 1 X Electrical Detector
Contact Sw only
Normal
ZEDCSPN 8E 1 1 1 X X 1 X Electrical Detector
Contact Sw. &
Plunger Normal
ZEDCSPR 8F 1 1 1 X X 1 X Electrical Detector
Contact Sw. &
Plunger Reverse
ZEDCSR 8B 1 1 1 X X 1 X Electrical Detector
Contact Sw. only
Reverse
ZEDESC 8D 1 1 1 X X 1 X Electrical Detector
ESCapement slide
contact
ZEDPLCN 8G 1 1 1 X X 1 X Electrical Detector
PLunger Lock
Contact Normal
ZEDPLCR 8H 1 1 1 X X 1 X Electrical Detector
PLunger Lock
Contact Reverse
ZELL 9A 1 1 1 X X 1 X Electric Lock Lever
ZELLCC 9B 1 1 1 X X 1 X Electric Lock Lever
Contact Closed
ZELCO 9C 1 1 1 X X 1 X Electric Lock Lever
Contact Open
ZELP 9G 1 1 1 X X 1 X Electric Lock
Plunger
ZELRS 9D 1 1 1 X X 1 X Electric Lock
Releasing Switch
ZELRSCC 9E 1 1 1 X X 1 X Electric Lock
Releasing Switch
Contact Closed
ZELRSCO 9F 1 1 1 X X 1 X Electric Lock
Releasing Switch
Contact Open
ZEREV 6P 1 1 1 X X 1 X Electrical
REVerser
ZESMCCON 10F 1 1 1 x x 1 x Electrical Sw.
Mach. Contact
Change-Over
(Nippon)
© RailCorp Page 34 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZESMCN 10A 1 1 1 1 X 1 X Electrical Sw.
Mach. Contact
Normal
ZESMCNN 10D 1 1 1 1 X 1 X Electrical Sw.
Mach Contact
Normal (Nippon)
ZESMCR 10B 1 1 1 1 X 1 X Electrical Sw.
Mach. Contact
Reverse
ZESMCCL 10C 1 1 1 1 X 1 X Electrical Sw.
Mach Contact
Clamp Lock
ZESMCRN 10E 1 1 1 1 X 1 X Electrical Sw.
Mach. Contact
Reverse (Nippon)
ZESML 10P 1 1 1 1 X 1 X Electrical Sw.
Mach. Lock
ZFL1 11M 1 1 1 X X 1 X FLasher unit type
1 (thermal type)
ZFL2 11N 1 1 1 X X 1 X FLasher unit type
2 (email type)
ZRFC 2R 1 1 1 X X 1 X FLashing Relay
Contact
ZFUSE 13A 1 1 1 X X 1 X FUSE
ZFUSE1 13B 1 1 1 X X 1 1 FUSE type 1
(without wire tags)
ZGPO 13D 1 1 1 X X 1 X General Purpose
Outlet (ie. 240V)
ZHDCB 2I 1 1 1 X X 1 X Heavy Duty
Contactor Busbar
ZHDCFCC 2G 1 1 1 X X 1 X Heavy Duty
Contactor Front
Contact Closed
ZHDCFCO 2H 1 1 1 X X 1 X Heavy Duty
Contactor Front
Contact Open
ZIEC 18A 1 1 1 X X 1 X Indicator Eyeball
inseparate Case
ZIED 18B 1 1 1 X X 1 X Indicator Eyeball in
Diagram
ZIL 18D 1 1 1 X X 1 X Indicator Lamp
ZILC 18E 1 1 1 X X 1 X Indicator Lamp in
sep. case
ZILEV 18G 1 1 1 X X 1 X Indicator LEVer
light
ZILMI1 21M 1 1 1 X X 1 X Indicator Lamp
Module
Incandescent type
1
ZILML1 21A 1 1 1 X X 1 X Indicator Lamp
Module LED type
1 (3mm LED)
ZILML2 21B 1 1 1 1 X 1 X Indicator Lamp
Module LED type
2 (3mm LED)
ZILML3 21D 1 1 1 X X 1 X Indicator Lamp
LED type 3 (3mm
LED)
ZILML4 21E 1 1 1 X X 1 X Indicator Lamp
Module LED type
4 (3mm LED)
© RailCorp Page 35 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZILML5 21F 1 1 1 X X 1 X Indicator Lamp
Module LED type
5 (3mm LED)
ZILML6 21C 1 1 1 X X 1 X Indicator Lamp
Module LED type
6 (3mm LED)
ZILSI 18H 1 1 1 X X 1 X Indicator Lamp
with Store no.1
transformer
ZIRNT 18C 1 1 1 X X 1 X Indicator Repeater
Needle Type
ZIRST 18F 1 X 1 X X 1 X Indicator Repeater
Semaphore Type
ZLA 13P 1 1 1 X X 1 X Lighting Arrestor
ZLA2 13Q 1 1 1 X X 1 X Lighting Arrestor
type 2
ZLCCRNC 17G 1 1 1 X X 1 X Lever Contact
CatchRodNormally
Closed
ZLCCRNO 17H 1 1 1 X X 1 X Lever Contact
CatchRodNormally
Open
ZLCE 17B 1 1 1 1 X 1 X Lever Contact
Electric switch
ZLCMCO 17L 1 1 1 1 X 1 X Lever Contact
Minature type
Change Over
ZLCMNC 17J 1 1 1 X X 1 X Lever Contact
Minature type
Normally Closed
ZLCMNO 17K 1 1 1 X X 1 X Lever Contact
Minature type
Normally Opened
ZLCR 17A 1 1 1 X X 1 X Lever Contact
Rotary
ZLCS 17C 1 1 1 X X 1 X Lever Contact
route Setting
switch
ZLINK1 13K 1 1 1 X X 1 X LINK type 1
ZLOC 13M 1 X 1 X X 1 X LOCation terminal
single
ZLOC1 13N 1 X 1 X X 1 1 LOCation terminal
double (type 1)
ZLQSC 6J 1 1 1 1 X 1 X Lower Quadrant
Signal Contact
ZMETER 13R 1 1 1 X X 1 1 METER (eg.
voltage, current,
etc)
ZMOTOR 7A 1 1 1 X X 1 X MOTOR (eg.
banner signal)
ZMOTOR2 7C 1 X 1 X X 1 X MOTOR type 2
(western railroad
boom gates)
ZMOTOR3 7D 1 X 1 X X 1 X MOTOR type 3
(western railroad
boom gates type
B)
ZMOTOR4 7B 1 1 1 X X 1 X MOTOR type 4
(eg. nippon points
motor)
© RailCorp Page 36 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZMOTOR5 7E 1 X 1 X X 1 X MOTOR type 5
(eg. pedestrian
barriers)
ZNVRAC 3K 1 1 1 X X 1 X Non Vital Relay
A.C (ie. HH23
type)
ZNVRBCC 1N 1 1 1 X X 1 X Non Vital Relay
Back Contact
Closed
ZNVRBCO 1M 1 1 1 X X 1 X Non Vital Relay
Back Contact
Open
ZNVRDC 3N 1 1 1 X X 1 X Non Vital Relay
D.C. (ie. HH23
type)
ZNVRDCP 3Q 1 1 1 X X 1 X Non Vital Relay
D.C. (PC board
type)
ZNVRDFCC 1P 1 1 1 X X 1 X Non Vital Relay
Dependant Front
Contact Closed
ZNVRDFCO 1Q 1 1 1 X X 1 X Non Vital Relay
Dependant Front
Contact Open
ZNVRFCC 1J 1 1 1 X X 1 X Non Vital Relay
Front Contact
Closed
ZNVRFCO 1K 1 1 1 X X 1 X Non Vital Relay
Front Contact
Open
ZPB3F 16A 1 1 1 X X 1 X Push Button 3
position (push to
make)
ZPB3FM 16C 1 1 1 X X 1 X Push Button 3
position (pull to
break)
ZPB3T 16B 1 1 1 X X 1 X Push Button 3
position (pull to
make)
ZPBBBCO 16R 1 1 1 X X 1 X Push Button Block
Bell Change Over
type
ZPBNC 16G 1 1 1 X X 1 X Push Button
Normally Closed
ZPBNO 16H 1 1 1 X X 1 X Push Button
Normally Open
ZPBRSNO 16Q 1 1 1 X X 1 X Push Button
Release Switch
Normally Open
ZPBTF 16J 1 1 1 X X 1 X Push Button (push
to break/push to
make)
ZPC 13J 1 1 1 X X 1 1 Plug Coupler
ZPSM1 11A 1 1 1 X X 1 X Power Supply
Module type 1
ZR3P 3H 1 1 1 X X 1 X Relay a.c.3
Position
ZRAC 3B 1 1 1 X X 1 X Relay A.C.
ZRACDE 3E 1 1 1 X X 1 X Relay A.C. Double
Element
© RailCorp Page 37 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZRACSR 3I 1 1 1 X X 1 X Relay A.C. Slow
Release
ZRACTS 4E 1 1 1 X X 1 X Relay A.C. Track
relay Shelf
ZRBCC 1E 1 1 1 X X 1 X Relay Back
Contact Closed
ZRBCO 1D 1 1 1 X X 1 X Relay Back
Contact Open
ZRDC 3A 1 1 1 X X 1 X Relay D.C.
ZRDCB 3D 1 1 1 X X 1 X Relay D.C. Biased
ZRDCL 3P 1 1 1 X X 1 X Relay D.C.
Latched
ZRDQ1 4C 1 1 1 X X 1 X Relay D.C. QTR1
type
ZRDCSP 3G 1 1 1 X X 1 X Relay D.C. Slow
Pick
ZRDCSPR 3M 1 1 1 X X 1 X Relay D.C. Slow
Pick andRelease
ZRDCSR 3J 1 1 1 X X 1 X Relay D.C. Slow
Release
ZRDCT 4A 1 1 1 X X 1 X Relay D.C. Timer
ZRDCTQ3 4B 1 1 1 X X 1 X Relay D.C.Timer
QTD3 type
ZRDFCC 1G 1 1 1 X X 1 X Relay Dependant
Front Contact
Closed
ZRDFCO 1H 1 1 1 X X 1 X Relay Dependant
Front Contact
Open
ZRES 20G 1 1 1 X X 1 X RESistor fixed
ZRESV 20H 1 1 1 X X 1 X RESistor Variable
ZRESV2 20I 1 1 1 X X 1 X RESistor Variable
type 2
ZRESV3 20J 1 1 1 1 1 1 X RESistor Variable
type 3
ZRFCC 1A 1 1 1 X X 1 X Relay Front
Contact Closed
ZRFCO 1B 1 1 1 X X 1 X Relay Front
Contact Open
ZRTJS 4I 1 1 1 X X 1 X Relay Rack
Jeumont
Schneider
ZSAC 4N 1 1 1 X X 1 X Solenoid A.C.
ZSCNC 15G 1 1 1 X X 1 X Switch Contact
Normally Closed
ZSCNO 15H 1 1 1 X X 1 X Switch Contact
Normally Open
ZSDC 4M 1 1 1 X X 1 X Solenoid D.C.
ZSDP 15D 1 1 1 X X 1 X Switch Double
Pole
ZSDPS 15F 1 1 1 X X 1 X Switch Double
Pole Snap action
ZSLC 6A 1 1 1 X X 1 X Search Light
signal Contact
ZSLCN 6B 1 1 1 X X 1 X Search Light
signal Contact
Normal
ZSLINDN 6C 1 1 1 X X 1 X Search Light
signal INDicatioN
(signal operating)
© RailCorp Page 38 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZSSHELF 15P 1 1 1 X X 1 X Switch SHELF
type (used with
mechanical levers)
ZSSHELF1 15Q 1 1 1 X X 1 X Switch SHELF
type 2 (used with
mechanical
levers)
ZSSPNC 15A 1 1 1 X X 1 X Switch Single Pole
Normally Closed
ZSSPNO 15B 1 1 1 X X 1 X Switch Single Pole
Normally Open
ZSSPNOD 15N 1 1 1 X X 1 X Switch Single Pole
Normally Open for
Dimming
ZSSPS 15C 1 1 1 X X 1 X Switch Single Pole
Snap action
ZSTP1 14M 1 1 1 X X 1 X STraP type 1 (for
timer relays -
ZRDCT)
ZSTP2 14N 1 1 1 X X 1 X STraP type 2 (for
timer relays -
ZRDCT)
ZSTP3 14O 1 1 1 X X 1 X STraP type 3 (for
timer relays -
ZRDCT)
ZRTP4 14P 1 1 1 X X 1 X STraP type 4 (for
timer relays -
ZRDCT)
ZTSCN 14B 1 1 1 X X 1 X Train Stop Contact
Normal
ZTSCNR 14F 1 1 1 X X 1 X Train Stop Contact
made Normal to
almost Reverse
ZTSCR 14C 1 1 1 X X 1 X Train Stop Contact
Reverse
ZTSM 14A 1 1 1 X X 1 X Train Stop Motor
ZUQC 5A 1 1 1 X X 1 X Upper Quadrant
Contact (0
degrees)
ZUQC0010 5B 1 1 1 X X 1 X Upper Quadrant
Contact (0 to 10
degrees)
ZUQC0045 5C 1 1 1 X X 1 X Upper Quadrant
Contact (0 to 45
degrees)
ZUQC0088 5D 1 1 1 X X 1 X Upper Quadrant
Contact (0 to 88
degrees)
ZUQC45 5E 1 1 1 X X 1 X Upper Quadrant
Contact (45
degrees)
ZUQC0690 5F 1 1 1 X X 1 X Upper Quadrant
Contact (6 to 90
degrees)
ZUQC4590 5G 1 1 1 X X 1 X Upper Quadrant
Contact (45 to 90
degrees)
ZUQC8890 5H 1 1 1 X X 1 X Upper Quadrant
Contact (88 to 90
degrees)
ZVARES 20K 1 1 1 X X 1 X VAREStor
© RailCorp Page 39 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZNWAR 19G 1 X 1 X * * * New Work
ARrow
ZRWAR 19H 1 X 1 X * * * Removal Work
ARrow
Block Fig X Y - 0 +
Name No. + - + - 90 90 Description
ZLABEL 19I 1 X 1 X X X X Label for
extended sheets
© RailCorp Page 40 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 41 of 63
Issued September 2010 UNCONTROLLED WHEN PRINTED Version 1.6
Superseded by T MU MD 00006 ST v1.0 RailCorp Engineering Manual — Design — Signal
CAD and Drafting Manual – Signal – Section 6 TMD 0001
© RailCorp Page 42 of 63
© RailCorp Page 43 of 63
© RailCorp Page 44 of 63
© RailCorp Page 45 of 63
© RailCorp Page 46 of 63
© RailCorp Page 47 of 63
© RailCorp Page 48 of 63
© RailCorp Page 49 of 63
© RailCorp Page 50 of 63
© RailCorp Page 51 of 63
© RailCorp Page 52 of 63
© RailCorp Page 53 of 63
© RailCorp Page 54 of 63
© RailCorp Page 55 of 63
© RailCorp Page 56 of 63
© RailCorp Page 57 of 63
© RailCorp Page 58 of 63
© RailCorp Page 59 of 63
© RailCorp Page 60 of 63
© RailCorp Page 61 of 63
© RailCorp Page 62 of 63
© RailCorp Page 63 of 63