Sei sulla pagina 1di 8

UNIVERSIDAD NACIONAL DE

SAN AGUSTÍN

Facultad de Ingeniería de Producción y


Servicios
Escuela Profesional de Ingeniería Eléctrica

Curso: ESTABILIDAD DE SISTEMAS DE POTENCIA

Alumna : UMASI HUAMANI , MIRIAM FIORELLA


VILCA YEPEZ , ANTHONY
NUÑEZ CHOQUE , VICTOR ABEL
CHOQQUEPURA CACERES, JHONATAN

Tema: INFORME NRO3 : SIMULACION DE LA CENTRAL


TERMICA MOLLENDO DIESEL

Docente: ING. YURI ALENCASTRE

Arequipa-Perú
2019
Escuela profesional de
Ingenieria Electrica

MODELADO EN PSAT DE LA CENTRAL TERMICA DE MOLLENDO DIESEL


MODELED IN PSAT OF THE DIESEL MOLLENDO THERMAL CENTRAL

CHOQQUEPURA CACERES ,JHONATAN

NUNEZ CHOQUE ,VICTOR ABEL

UMASI HUAMANI , MIRIAM FIORELLA

VILCA YEPEZ , ANTHONY

DEDICATORIA

El presente informe esta dedicado a nuestra familia por ser un soporte emocional y
económico importante en nuestro proceso de formación y al docente del curso por ser
nuestro guía fundamental en esta etapa de nuestra carrera

AGRADECIMIENTO

- Agradecemos a Dios por permitirnos estar aquí .


- A la Universidad por brindarnos las herramientas necesarias para
- A nuestras familias por su apoyo incondicional
- Al docente del curso por aportar a nuestra formación

RESUMEN

Se realizo la descomposición y el análisis del circuito perteneciente a la Central Termica de


Mollendo Diesel , con la información técnica en Linea brindada en por el Comité De
Operacion Económica Del Sistema Interconectado Nacional (COES) y el archivo de
simulacion en el software de Digsilent con datos otorgados por la Sociedad Electrica del Sur
Escuela profesional de
Ingenieria
Oeste (SEAL) ; para poder extraer de maneraElectrica
adecuada los valores numéricos de cada Generador ,
transformador y línea que corresponde a la Central térmica de Mollendo .

Una vez extraídos los datos técnicos , se toman los datos para convertirlos en valores pu y
poder introducirlos en el software PSAT , donde se introducirán valores completamente
reales .

Finalmente los valores resultantes de flujo de potencia en el software didáctico PSAT serán
comparados con los resultados del flujo en Digsilent .

PALABRAS CLAVE

PSAT: Power System Analysis Toolbox , es una caja de herramientas (toolbox) para Matlab
y GNU Octave que permite realizar análisis de sistemas de potencia. Esta caja de
herramientas permite incorporar sistemas eléctricos de potencia mediante un entorno gráfico
basado en Simulink.

SEAL : Sociedad Electrica del Sur Oeste , distribuidora de electricidad en toda la región
Arequipa, con energía del Sistema Interconectado Nacional, manteniendo aún la generación
a través de unos poco Sistemas Aislados, los que tienen a ser reemplazados a corto plazo
por dicho Sistema.

COES : Comité De Operacion Económica Del Sistema Interconectado Nacional , es una


entidad privada, sin fines de lucro y con personería de Derecho Público. Está conformado
por todos los Agentes del SEIN (Generadores, Transmisores, Distribuidores y Usuarios
Libres) y sus decisiones son de cumplimiento obligatorio por los Agentes. Su finalidad
principal es coordinar la operación de corto, mediano y largo plazo del SEIN al mínimo
costo,preservando la seguridad del sistema.

Flujo de Potencia : También conocido como flujo de carga, es una herramienta importante
que involucra análisis numérico aplicado a un sistema de potencia operando en estado
estacionario . En el estudio del flujo de potencia usualmente se usa una notación
simplificada tal como el diagrama unifilar y el sistema por unidad, y se centra en varias
formas de la potencia eléctrica AC (por ejemplo, voltajes, ángulos de los voltajes, potencia
activa y potencia reactiva).
Escuela profesional de
Ingenieria Electrica

ABSTRACT

The decomposition and analysis of the circuit of the Mollendo Diesel Thermal Power Plant
was carried out, with the technical information on the Line provided in the Committee of
Economic Operations of the National Interconnected System (COES) and the simulation file
in the Digsilent software with data granted by the Electricity Company of the South West

(SEAL); to be able to adequately extract the numerical values of each Generator,


transformer and line that corresponds to the Mollendo Thermal Power Plant.

Once we extract the technical data, we convert it into data to convert it into values, and we
can introduce it into the PSAT software, where we will introduce completely real values.

Finally, the resulting values of power flow in the didactic software will be compared with the
results of the flow in Digsilent.

KEYWORDS

PSAT: Power System Analysis Toolbox, is a toolbox for Matlab and GNU Octave that allows
analysis of power systems. This toolbox allows the incorporation of electrical power systems
through a graphical environment based on Simulink.

SEAL: Sociedad Electrica del Sur Oeste, electricity distributor in the entire Arequipa region,
with energy from the National Interconnected System, still maintaining the generation
through a few Isolated Systems, which have to be replaced in the short term by said System.

COES: Economic Operation Committee of the National Interconnected System, is a private


entity, non-profit and with Public Law. It is made up of all SEIN Agents (Generators,
Transmitters, Distributors and Free Users) and its decisions are mandatory by the Agents. Its
main purpose is to coordinate the short, medium and long term operation of the SEIN at the
minimum cost, preserving the security of the system.

Power Flow: Also known as a load flow, it is an important tool that involves numerical
analysis applied to a power system operating in a stationary state. In the study of power flow
usually simplified notation is used such as the one-line diagram and the system per unit, and
focuses on various forms of AC electrical power (eg voltages, angle of voltages, active power
and power). reactive).
Escuela profesional de
Ingenieria Electrica

INTRODUCCION

En el siguiente informe describiremos el comportamiento de la Central Termica de


Mollendo Diesel mediante la simulacion en PSAT de la misma , tomando como fuente de
Datos a COES y SEAL , con el objetivo de hacer el diseño correcto del sistema ;acentuando
de esta manera los conocimiento adquiridos en clase .

PLANTEAMIENTO DEL PROBLEMA

En años recientes hemos sido testigos del constante avance de la tecnología ,al cual
tenemos que hacerle el alcance dominando diferentes softwares de simulacion útiles para
realizar el procesamiento de datos reales .

En vista de que la Empresa distribuidora SEAL ,solo hace uso del software Disgsilent para la
simulacion de sus sistemas ,tenemos la necesidad de hacer la modelación de la Central
Termica de Mollendo Diesel en un software mas didáctico como es PSAT utilizando los
mismos valores reales .

IMPORTANCIA

Es de vital importancia para los estudiantes del curso de “Estabilidad de Sistemas de


Potencia “ de la Escuela Profesional de Ingenieria Electrica , poner en practica los
conocimientos adquiridos en la materia para incursionar en el rubro de Investigacion y
profundizar los conceptos básicos adquiridos a lo largo de la carrera .
Escuela profesional de
Ingenieria Electrica

OBJETIVOS

OBJETIVO CENTRAL

 Realizar el modelado en PSAT de la Central Termica de Mollendo Diesel

OBEJTIVOS ESPECIFICOS

 Extraer datos técnicos de la plataforma virtual del COES


 Extraer los datos técnicos del software Digsilent
 Concurrir a la distribuidora de energía para completar los datos si es que fuese
necesario .
 Realizar un proceso matemático para llevar los datos técnicos a valores por unidad .
 Introducir los valores reales en el software PSAT y correr el flujo
 Hacer una comparación de datos entre los resultados obtenidos en Digsilent con los
datos obtenidos en PSAT .

METODOLOGIA

TIPO Y DISEÑO DE INVESTIGACION

El tipo de proyecto realizado es de tipo Investigacion-accion y el diseño que hara a través


de estudios cuantitativos obtenidos de Digsilent previamente descargados del portal web
del COES .

HIPOTESIS

La simulación de la Central Térmica Mollendo Diesel en el software PSAT generara el


análisis mas didáctico a comparación del software Digsilent ,acentuando al mismo tiempo
los conocimientos de sistemas de potencia adquiridos en clase .

ANALISIS E INTERPRETACION DE LOS RESULTADOS


Escuela profesional de
Ingenieria Electrica

CONCLUSIONES

BIBLIOGRAFIA

 http://www.coes.org.pe/Portal/home/
 http://www.seal.com.pe/Paginas/Inicio.aspx
 http://www.osinergmin.gob.pe/
 https://www.upv.es/entidades/ICE/info/U0594888.pdf
 https://www.ugr.es/~rarroyo/material/Investigaci%C3%B3n.pdf
 http://www.coes.org.pe/Portal/home/
 http://www.seal.com.pe/Paginas/Inicio.aspx
Escuela profesional de
Ingenieria Electrica

Potrebbero piacerti anche