Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
1. Determine the occupancy category of the building or other structures. (See NSCP 2015, Table
103-1)
2. Determine the basic wind speed, V, for the applicable risk category. (See NSCP 2015, Figure
2071.5-1A,B or C)
3. Determine wind load parameters:
Wind directionality factor, 𝐾𝑑 , (See Section 207A.6 and Table 207A.6-1)
Exposure Category B, C or D, (See Section 207A.7)
Topographic factor, 𝐾𝑧𝑡 , (See Section 207A.8 and Figure 207A.8-1)
𝑲𝒛𝒕 = (𝟏 + (𝑲𝟏 )(𝑲𝟐 )(𝑲𝟑 ))𝟐
Where:
Note:
If the site conditions and locations of structures do not meet all the conditions specified in
Section 207A.8.1 then 𝑲𝒛𝒕 = 1.0
4. Determine the velocity pressure exposure coefficient, 𝐾𝑧 or 𝐾ℎ , (See Section 207C.4.4, Table
207C.3-1)
6. Determine external pressure coefficient, (𝐺𝐶𝑝 ), using Figure 207C.4-1 for flat and gable roofs.
7. Calculate wind pressure, 𝑝, from the Equation 207C.4-1.
Where:
Where:
𝑝 = wind pressure
𝐴 = projected area normal to the wind