DEFLECTION LIMITS AS PER IS 800:2007

Live load/wind load Purlin and girts Elastic cladding Span/150


Brittle cladding Span/l 80
Live load simple span Elastic cladding Span/240
Brittle cladding Spatr/300
Live load cantilever span Elastic cladding Span/120
Brittle cladding Span/150
Live load/wind load rafter supporting Profiled Metal Sheeting Sparr/180
Plastered Sheeting Span/240
Crane load,manual Gantry Crane Spaa/500
Crane load, electric ope up to 50t Gantry Crane Span/150
Crane load, electric ope over 50t Gantry Crane Span/1000
no cranes Column Elastic cladding Height/l 50
Masonry/Brittle cladding Height/240
Crane + wind Gantry (lateral) Crane (absolute) Span/400
Relative displacement 10 mm
Crane + wind Column/frame Gantry (Elastic cladding pendent operated) Height/200
Gantry (Brittle cladding; cab Height/400
Live load Floor and Roof Elements not susceptible to cracking Sparr/300
Elements susceptible to cracking Spsm/360
Live load Cantilever Elements not susceptible to cracking Span/l 50
Elements susceptible to cracking Span/180
Wind Building Elastic cladding Height/300
Brittle cladding Height/500
Wind Inter storey drift -- Storey height/300