= 2764,169 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 2764,169 m3
= 3178,795 m3
b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve (C.2)
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana:
H = (3/2) Dt
C-1
C-2
3 3178,795 x 8
=√
3 x 3,14
= 13,924 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3 (C.4)
= 0,13 x (13,924)3
= 353,199 m3
Volume Silinder, Vs:
Vs = Vt – Ve (C.5)
= 3178,795 – 353,199
= 2410,97 m3
Tinggi Tangki Total, Ht:
Tinggi slinder, H = (3/2) × Dt (C.6)
= (3/2) x 13,924 m
= 20,886 m
Tinggi ellipsoidal, h = (1/4) Dt (C.7)
= (1/4) x 13,924 m
= 3,481 m
Maka, Ht = H + h (C.8)
= (20,886 + 3,481) m
= 17,405 m
Tebal Dinding Tangki, t:
P×D
t = +C (Tabel 14-4 Peter Timmerhaus, 1991) (C.9)
2 ×SE- 0,2 × P
Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 13,924 m
C-3
t = 0,003 cm
OD = 2t + Dt (C.10)
= 2 (0,003) + 13,924 m
= 13,947 m
= 1651,006 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 1651,006 m3
C-4
= 1898,656 m3
b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana: H = (3/2) Dt
h = (1/4) Dt (Tabel 6-51 Perry,1997)
maka,
3 Vt x 8
Dt = √ 3 x π
3 1898,656 x 8
=√ 3 x 3,14
= 11,726 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3
= 0,13 x (11,726)3
= 211,153 m3
Volume Silinder, Vs:
Vs = Vt – Ve
= 1898,656 – 211,153
= 1687,503 m3
Tinggi Tangki Total, Ht:
Tinggi slinder, H = (3/2) × Dt
= (3/2) x 11,726 m
= 17,589 m
Tinggi ellipsoidal, h = (1/4) Dt
= (1/4) x 11,726 m
= 2,931 m
Maka, Ht = H + h
= (17,589 + 2,931) m
= 20,521 m
C-5
Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 11,726 m
S = working stress yng diizinkan = 13700 psi = 932,226 atm
E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
1 atm x 11,726 m
t = + 0,0032 m
(2 x 932,226 atm x 0,85)- (0,2 x 1 atm)
t = 1,06 cm
OD = 2t + D
= 2 (1,06) + 11,726 m
= 11,747 m
Kondisi operasi
Temperatur : 30 oC
Tekanan : 1 atm
Laju alir, W : 11379,36 kg/jam
Densitas, 𝜌 : 1225,18 kg/m3
Lama persediaan, t : 7 hari
Safety Factor : 15%
Perhitungan:
C-6
a. Volume tangki, V
W x t x 24 jam/hari
V =
ρ
kg
11379,36 x 7 hari x 24 jam/hari
jam
=
1225,18 kg/m3
= 1560,36 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 1560,36 m3
= 1794,42 m3
b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana: H = (3/2) Dt
h = (1/4) Dt (Tabel 6-51 Perry,1997)
maka,
3 Vt x 8
Dt = √
3xπ
3 1898,656 x 8
=√
3 x 3,14
= 11,507 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3
= 0,13 x (11,507)3
= 199,56 m3
Volume Silinder, Vs:
Vs = Vt – Ve
= 1794,42 – 199,56
= 1594,86 m3
C-7
Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 11,726 m
S = working stress yng diizinkan = 13700 psi = 932,226 atm
E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
1 atm x 11,726 m
t = + 0,0032 m
(2 x 932,226 atm x 0,85)- (0,2 x 1 atm)
t = 1,06 cm
OD = 2t + D
= 2 (1,06) + 11,726 m
= 11,528 m
Jumlah : 1 unit
Data :
Temperatur , T = 30°C = 86°F
Laju Alir, W = 16199,05 kg/jam = 595,314 lb/menit
Densitas, ρ = 981,244 kg/m3 = 61,258 (lb)/ft3
Viscositas, μ = 0,312 cP = 0,00021 (lb)/ft
Kapasitas Pompa, Qf:
Qf = 1 + (0,1×w/ρ) (C.11)
= 1 + (0,1× (595,314 lb/menit)/(61,258 lb/ft3 ))
= 0,161 ft3/detik
Qf = 9,718 ft3/menit
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
1
IPS = 22 in
ID = 2,469 in = 0,206 ft
OD = 2,875 in = 0,240 ft
Luas Penampang = 0,033 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a (C.13)
= (0,161 ft3/detik)/( 0,033 ft2)
= 4,875 ft/detik
C-9
Panjang ekivalen,
Le = 2,400 ft + 5,144 ft + 0,154 f
= 7,698 ft
4. Menghitung Kehilangan Fraksi
a. Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (Geankoplis,1993 tabel 2.10-1)
V2
Hf = Kf ( ) (C.15)
2 x α xgc
ft 2
(4,875 )
detik
=0, 75( )
2 x 1 x 32,174
= 997,487 ft.lbf/lbm
b. Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( ) (C.16)
2 x α xgc
ft 2
(4,875 )
detik
= 0,17( )
2 x 1 x 32,174
= 0,062 ft.lbf/lbm
c. Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( ) (C.17)
2 x α xgc
ft 2
(4,875 detik)
= 6( )
2 x 1 x 32,174
= 2,216 ft.lbf/lbm
Total Hf = 0,277 ft.lbf/lbm + 0,062 ft.lbf/lbm + 2,216 ft.lbf/lbm
= 2,556 ft.lbf/lbm
ft 2
(4,875 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174
= 0,203 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
) (C.19)
ft 2
(4,875 )
detik
= (1-0)x ( )
2 x 1 x 32,174
= 0,369 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx ( )x ( ) (C.20)
ID 2 x α x gc
ft 2
30 (4,875 )
detik
= 4 x 30 x (
7,698
) x (2 x 1 x 32,174)
= 137,977 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff (C.21)
= 0,203 ft.lbf/lbm + 0,369 ft.lbf/lbm + 137,977 ft.lbf/lbm
= 137,977 ft.lbf/lbm
= 191,939 ft.lbf/lbm
Daya Pompa:
P = m x Wp (C.24)
= 9,921 lbm/s x 212,687 ft.lbf/lbm
= 1904,405 ft.lbf/s = 3,462 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
C-13
Suction pipe
SN = 40
1
IPS = 22 in
ID = 2,469 in = 0,206 ft
OD = 2,875 in = 0,240 ft
Luas Penampang = 0,033 ft2
Bahan Konstruksi = pipa commercial steel
ft 2
(1,345 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,021 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(1,345 )
detik
= 0,17( )
2 x 1 x 32,174
= 0,004 ft.lbf/lbm
C-15
ft 2
(1,345 )
detik
=6 ( )
2 x 1 x 32,174
= 0,168 ft.lbf/lbm
Total Hf = 0,021 ft.lbf/lbm + 0,004 ft.lbf/lbm + 0,0168 ft.lbf/lbm
= 0,194 ft.lbf/lbm
ft 2
(1,345 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174
= 0,015 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(1,345 )
detik
= (1-0)x ( )
2 x 1 x 32,174
= 0,028 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx ( )x ( )
ID 2 x α x gc
ft 2
30 (1,345 )
detik
= 4 x 30 x ( ) x (2 x 1 x 32,174)
7,698
= 38,078 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,200 ft.lbf/lbm + 0,362 ft.lbf/lbm + 38,078 ft.lbf/lbm
C-16
= 38,122 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 66,404 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 2,789 x 66,404 ft.lbf/lbm
= 184,931 ft.lbf/s = 0,33 hp
Qf = 9,7183 ft3/menit
Penentuan Ukuran Pipa
Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,161972 ft3/detik)0,45× (61,2571 (lb/ft3)0,13
= 2,935233 in
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 3 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
ft 2
(0,2503 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,0073 ft.lbf/lbm
C-19
ft 2
(0,2503 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,00166 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf =Kf ( )
2 x α xgc
ft 2
(0,2503 )
detik
=6 ( )
2 x 1 x 32,174
= 0,00536 ft.lbf/lbm
Total Hf = 0,0073 ft.lbf/lbm + 0,00166 ft.lbf/lbm + 0,00536 ft.lbf/lbm
= 0,0674 ft.lbf/lbm
ft 2
(0,2503 detik)
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )
= 0,000536 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,2503 )
detik
= (1-0)x ( )
2 x 1 x 32,174
= 0,000974 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff = 4 x f x ( ID ) x ( 2 x α x gc)
C-20
ft 2
0,00454 (0,2503 detik)
=4 x 0,00545 x (0,25566) x ( 2 x 1 x 32,174 )
= 0,00346 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000536 ft.lbf/lbm + 0,000974 ft.lbf/lbm + 0,00346 ft.lbf/lbm
= 0,003461 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 18,7577 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 184,931 ft.lbf/s
= 0,33 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 3 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
ft 2
(0,2503 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,0073 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf( )
2 x α xgc
ft 2
(0,2503 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,00166 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,2503 )
detik
=6 ( )
2 x 1 x 32,174
= 0,00536 ft.lbf/lbm
Total Hf = 0,0073 ft.lbf/lbm + 0,00166 ft.lbf/lbm + 0,00536 ft.lbf/lbm
= 0,0674 ft.lbf/lbm
ft 2
(0,2503 )
detik
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )
= 0,000536 ft.lbf/lbm
C-24
ft 2
(0,2503 )
detik
= (1-0)x ( 2 x 1 x 32,174 )
= 0,000974 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,2503 )
detik
=4 x 0,00545 x (
0,25566
) x ( 2 x 1 x 32,174 )
= 0,00346 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000536 ft.lbf/lbm + 0,000974 ft.lbf/lbm + 0,00346 ft.lbf/lbm
= 0,003461 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 18,7577 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 184,931 ft.lbf/s = 0,33 hp
C-25
Data :
Temperatur , T = 80°C = 176 °F
Laju Alir, W = 20.745,88 kg/jam = 12,7068 lb/s
Densitas, ρ = 984,3764 kg/m3 = 61,45262 (lb)/ft3
Viscositas, μ = 0,4416 cP = 0,00029 (lb)/ft
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 31/2 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
C-26
ft 2
(0,2067 )
detik
= 0,75 ( 2 x 1 x 32,174 )
= 0,00771 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf (2 x α xgc)
ft 2
(0,2067 )
detik
= 0,17 ( )
2 x 1 x 32,174
= 0,00175 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,2067 )
detik
= 6 ( 2 x 1 x 32,174 )
= 0,00616 ft.lbf/lbm
Total Hf = 0,00771 ft.lbf/lbm + 0,00175 ft.lbf/lbm + 0,00616 ft.lbf/lbm
= 0,07113 ft.lbf/lbm
C-28
ft 2
(0,2067 )
detik
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )
= 0,000565 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1- )x ( )
A2 2 x α x gc
ft 2
(0,2067 )
detik
= (1-0)x ( 2 x 1 x 32,174 )
= 0,0001208 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,2067 )
detik
= 4 x 0,00545 x (
0,25566
) x ( 2 x 1 x 32,174 )
= 0,006964 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000565 ft.lbf/lbm + 0,0001208 ft.lbf/lbm + 0,006964 ft.lbf/lbm
= 0,008557 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
-15,0098
=
-0,80
= 18,7622 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 238,4084 ft.lbf/s
= 0,43347 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa. (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 32,469 in = 0,205 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a
= (0,0926 ft3/detik)/( 0,647 ft2)
= 0,14133 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,205 ft × 0,14133 ft/detik × 75,2624 (lb)/ft3)/( 0,0002 (lb)/ft)
= 10.937,75 (Turbulent, NRe > 2100)
ft 2
(0,14133 detik)
=0,75 ( 2 x 1 x 32,174 )
= 0,00239 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,14133 detik)
= 0,17 ( 2 x 1 x 32,174 )
= 0,0000541 ft.lbf/lbm
C-32
ft 2
(0,14133 )
detik
=6( )
2 x 1 x 32,174
= 0,00191 ft.lbf/lbm
Total Hf = 0,00239 ft.lbf/lbm + 0,0000541 ft.lbf/lbm + 0,00191 ft.lbf/lbm
= 0,002203 ft.lbf/lbm
ft 2
(0,14133 )
detik
=0,55 x (1-0)x ( )
2 x 1 x 32,174
= 0,000175 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,14133 )
detik
= (1-0) x ( )
2 x 1 x 32,174
= 0,0003183 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,14133 )
detik
=4 x 0,00548 x (0,25566) x ( )
2 x 1 x 32,174
= 0,002915 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000175 ft.lbf/lbm + 0,0003183 ft.lbf/lbm + 0,002915 ft.lbf/lbm
= 0,003408 ft.lbf/lbm
C-33
= 18,7557 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
6,9698 lbm/s x 18,7557 ft.lbf/lbm
= 130,725 ft.lbf/s
= 0,2376 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
ft 2
(0,14133 )
detik
= 0,75 ( )
2 x 1 x 32,174
= 0,00239 ft.lbf/lbm
C-36
ft 2
(0,14133 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,0000541 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,14133 )
detik
=6 ( )
2 x 1 x 32,174
= 0,00191 ft.lbf/lbm
Total Hf = 0,00239 ft.lbf/lbm + 0,0000541 ft.lbf/lbm + 0,00191 ft.lbf/lbm
= 0,002203 ft.lbf/lbm
= 0,000175 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,14133 )
detik
=(1-0) x ( )
2 x 1 x 32,174
= 0,0003183 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
C-37
ft 2
0,00454 (0,14133 )
detik
=4 x 0,00548 x (
0,25566
)x ( 2 x 1 x 32,174
)
= 0,002915 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000175 ft.lbf/lbm + 0,0003183 ft.lbf/lbm + 0,002915 ft.lbf/lbm
= 0,003408 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 18,7557 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
6,9698 lbm/s x 18,7557 ft.lbf/lbm
= 130,725 ft.lbf/s
= 0,2376 hp
Data :
Temperatur , T = 82,81 °C = 181,058°F
Laju Alir, W = 9.366,52 kg/jam = 5,7369 lb/s
Densitas, ρ = 822,6675 kg/m3 = 51,3574 (lb)/ft3
Viscositas, μ = 0,2579 cP = 0,000173 (lb)/ft
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a
= (0,111707 ft3/detik)/( 0,647 ft2)
= 0,17264 ft/detik
C-39
Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,205 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,205 ft = 0,154 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,154 ft
C-40
= 7,6984 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, Geankoplis 1993)
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,17264 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,00347 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,17264 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,0000788 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,17264 )
detik
=6
2 x 1 x 32,174
= 0,00278 ft.lbf/lbm
Total Hf = 0,00347 ft.lbf/lbm + 0,0000788 ft.lbf/lbm + 0,00278 ft.lbf/lbm
= 0,003206 ft.lbf/lbm
= 0,000255 ft.lbf/lbm
C-41
= 0,000463 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff = 4 x f x ( ID ) x ( )
2 x α x gc
ft 2
0,00454 (0,17264 )
detik
=4 x 0,00548 x (
0,2575
) x ( 2 x 1 x 32,174 )
= 0,006375 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000255 ft.lbf/lbm + 0,000463 ft.lbf/lbm + 0,006375 ft.lbf/lbm
= 0,007093 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 18,76 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 5,7369 lb/s x 18,76 ft.lbf/lbm
C-42
= 107,628 ft.lbf/s
= 0,195 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
C-43
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
ft 2
(0,17264 )
detik
= 0,75( )
2 x 1 x 32,174
= 0,00347 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,17264 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,0000788 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,17264 )
detik
=6 ( )
2 x 1 x 32,174
= 0,00278 ft.lbf/lbm
Total Hf = 0,00347 ft.lbf/lbm + 0,0000788 ft.lbf/lbm + 0,00278 ft.lbf/lbm
C-45
= 0,003206 ft.lbf/lbm
= 0,000255 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1- )x ( )
A2 2 x α x gc
ft 2
(0,17264 )
detik
=(1-0)x ( )
2 x 1 x 32,174
= 0,000463 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,17264 )
detik
=4 x 0,00548 x (
0,2575
) x ( 2 x 1 x 32,174 )
= 0,006375 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000255 ft.lbf/lbm + 0,000463 ft.lbf/lbm + 0,006375 ft.lbf/lbm
= 0,007093 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
-15,0083
=
-0,80
= 18,76 ft.lbf/lbm
Daya Pompa:
P = m x Wp
= 5,7369 lb/s x 18,76 ft.lbf/lbm
= 107,628 ft.lbf/s
= 0,1956 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 1 1/4 in
ID = 1,38 in = 0,115 ft
OD = 1,66 in = 0,138 ft
Luas Penampang = 0,362 ft2
Bahan Konstruksi = pipa commercial steel
Dari data nilai NRe = 1.434,914 (< 2100, laminar flow) dan nilai ε/D = 0,0013
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,019
ft 2
(0,0429 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,0000215 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
C-49
ft 2
(0,0429 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,0000488 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,0429 )
detik
=6 ( )
2 x 1 x 32,174
= 0,000172 ft.lbf/lbm
Total Hf = 0,000021 ft.lbf/lbm + 0,0000488 ft.lbf/lbm + 0,000172 ft.lbf/lbm
= 0,000199 ft.lbf/lbm
= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1-
A2
)x ( 2 x α x gc
)
ft 2
(0,0429 )
detik
=(1-0)x ( )
2 x 1 x 32,174
= 0,0000287 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,0429 )
detik
=4 x 0,019 x (
0,155
) x ( 2 x 1 x 32,174 )
= 0,01134 ft.lbf/lbm
C-50
= 18,765 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 0,9473 lb/s x 18,765 ft.lbf/lbm
= 17,77 ft.lbf/s
= 0,0323 hp
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 2 1/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,000257 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
=0,17 ( )
2 x 1 x 32,174
= 0,0000582 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
= 6( )
2 x 1 x 32,174
= 0,002054 ft.lbf/lbm
Total Hf = 0,000257 ft.lbf/lbm + 0,0000582 ft.lbf/lbm + 0,002054 ft.lbf/lbm
= 0,002369 ft.lbf/lbm
ft 2
( 0,1484 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174
= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1- )x ( )
A2 2 x α x gc
ft 2
(0,1484 )
detik
= (1-0)x ( 2 x 1 x 32,174 )
C-54
= 0,000342 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,1484 )
detik
=4 x 0,00548 x (
0,20575
) x ( 2 x 1 x 32,174 )
= 0,00548 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,0000158 ft.lbf/lbm + 0,000342 ft.lbf/lbm + 0,00548 ft.lbf/lbm
= 0,00601 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
= 18,759 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 4,789 lb/s x 18,759 ft.lbf/lbm
= 89,849 ft.lbf/s
= 0,163 hp
C-55
Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 2 1/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
C-56
ft 2
(0,1484 )
detik
=0,75 ( )
2 x 1 x 32,174
= 0,000257 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
=0,17(
2 x 1 x 32,174
)
= 0,0000582 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
=6 ( )
2 x 1 x 32,174
= 0,002054 ft.lbf/lbm
Total Hf = 0,000257 ft.lbf/lbm + 0,0000582 ft.lbf/lbm + 0,002054 ft.lbf/lbm
= 0,002369 ft.lbf/lbm
C-58
= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1- )x ( )
A2 2 x α x gc
ft 2
(0,1484 )
detik
=(1-0)x ( )
2 x 1 x 32,174
= 0,000342 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,1484 )
detik
=4 x 0,00548 x (
0,20575
) x ( 2 x 1 x 32,174 )
= 0,00548 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,0000158 ft.lbf/lbm + 0,000342 ft.lbf/lbm + 0,00548 ft.lbf/lbm
= 0,00601 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ
-15,0721
=
-0,80
= 18,759 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 4,789 lb/s x 18,759 ft.lbf/lbm
= 89,849 ft.lbf/s
= 0,163 hp
= 583,367 ft3
Faktor keamanan fk = 20 %
Volume tangki = 700,04 ft3
Diameter tangki dan tinggi tangki :
Direncanakan :
-tinggi silinder : diameter (Hs:D) = 2:1
V = 1/4 π D2H (C.26)
700,04 ft3 = ¼ π D2 (2/1 D)
D = 8,108 ft
H = 16,21 ft
R = 4,05 ft =48,65 in
C-60
700,04 ft3
=1 = 13,563 ft
x 3,14 x (8,108 ft)2
4
g
ρ. h.
gc
Pdesain = + Poperasi (C.28)
144
61,21 x 13,563 x 1
= + 14,7 psia
144
= 20,46 psia
Faktor keamanan 20 % Pdesain = 1,2 x 20,46 psia = 24,55 psia
Tebal shell, t
PR
t = +(c . n) dimana R = D/2 (Mc Cetta, 1993) (C.29)
SE-0,6 P
24,55 x 4,05
= + (0,01 x 20)
(12650 x 0,8)- (0,6 x 24,55)
= 0,318 in
Dari tabel 5.4, Brownell, 1979, dipilih tebal tangki standar ½ in.
3. Tebal tutup
Tebal tutup dianggap sama dengan tebal shell karena terbuat dari bahan
yang sama = ½ in
C.15 Perhitungan Heat Exchanger (HE-01)
C-61
Fungsi :Memanaskan larutan metil formiat dari suhu 30,31oC menjadi 65oC
Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
Shell Side Tube Side
ID = 29 inch Number and Length = 120, 15’0’’
Baffle Space = 24.65 inch OD, BWG, pitch = 1½ , 18 BWG, 17⁄8 inch
Passes = 2 Passes = 4
1. Heat balance:
Metil formiat,Q = 2.082.011.936,07 joule/jam = 1.973.366,31 btu/jam
Air ,Q = 2.082.011.936,07 joule/jam = 1.973.366,31 btu/jam
4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.1 Data Temperatur HE-01
Fluida panas Fluida Dingin Selisih
212°F T1 s.tinggi 149°F t2 36°F
140°F T2 s.rendah 86,56°F t1 53°F
72°F T1-T2 Selisih 89,44°F t2 - t1 17°F
a. Menghitung ΔTLMTD
C-62
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t ) (C.30)
ln 2
(T2- t )
1
36℉ – 53℉
= 36℉
ln ( )
53℉
= 44,1473ºF
𝑇1 −𝑇2
b. R = (C.31)
𝑡2 −𝑡1
212℉ -140℉
=
149℉-86,56℉
= 0,8050 ºF
𝑡2 − 𝑡1
c. S = (C.32)
𝑇1 − 𝑡1
176℉- 86,56℉
=
212℉-86,56℉
= 0,713°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,845 maka,
d. Δt = FT . LMTD (C.33)
Δt = 0,845 × 44,1473℉
= 37,3045oF
= 705,318 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 1/2 in
Diameter dalam tube (ID) = 1,4 in
Jenis tube = 18 BWG
Pitch (PT) = 1 7/8 in square pitch
C-64
Panjang tube, L = 15 ft
Luas permukaan luar (a”) = 0, 3925 ft2/ft
e. Jumlah tube
A
Nt = (C.37)
L . a''
705,318 ft2
=
(15 ft)(0,3925 ft2 /ft)
= 119,7992 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 120 buah tube dengan OD tube 1 1/2 in, 17/8 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = square pitch
b. Jumlah aliran, n = 2 aliran (passes)
c. Pitch, PT = 1 7/8 in = 0,16 ft
d. Diameter shell, ID = 29 in = 2,4166 ft
e. Baffle Space = 0,85 × 29 in = 24,65 in
f. C = PT – OD tube
= 0,38 in
g. A Terkoreksi = Nt . L . a (C.38)
= 119,7992×15 ft ×0,3925 ft2/ft
= 705,318 ft2
h. Ud Terkoreksi
Q
UD = (C.39)
A . t
1.973.366,31 Btu/jam
= 2
705,318 ft . 37,3045°F
= 75 Btu/jam.ft2.oF
f. Analisa Kinerja HE
= 0,5 ft2
= 128,4706
jH = 200 (Fig. 24, Kern,1965)
Shell :
Viskositas pada tc = 131,28ºF
μ liquid = 0,3134 cP (Fig. 14, Kern, 1965)
= 0,7581 lb/ft.jam
1,48
Dc =
12
= 0,1233 ft (Fig. 28, Kern,1965)
D ×Gs
Res = (C.47)
μ
0,1233 ft × 71.940,0561 lb/jam ft2
=
0,7581 lb/ft.jam
= 11.703,0894 ft
jH = 60 (Fig. 28, Kern,1965)
d. Menentukan Thermal Function
Tube :
C-67
e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film Coefficient
(ho)
Tube :
1
ℎ𝑖 k c. μ 3
∅𝑡
= jH ( D) ( k ) (C.50)
0,3933 Btu/jam.lbm.ft. ºF
= 200 × ( ) × 0,5148 Btu/(hr) (ft2) (ºF/ft)
0,1166 ft
= 160,0567 Btu/hr.ft2. ºF
C-68
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡 (C.51)
c
Shell :
1
ℎ𝑜 k c. μ 3
∅𝑠
= jH (De) ( k ) (C.52)
= 215,4931 Btu/hr.ft2. ºF
k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k
(C.53)
= 215,4931 Btu/hr.ft2. ºF × 0,7829
= 168,7132 Btu/hr.ft2. ºF
= 149.39 Btu/hr.ft2. ºF
ID
hio = hi × x ∅𝑡 (C.55)
OD
= 149.39 Btu/hr.ft2. ºF x 0,9468
= 141,5 Btu/hr.ft2. ºF
Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).
215,4931 Btu/hr.ft2. ºF
= 131,28ºF + x
149.39 Btu/hr.ft2. ºF+ 215,4931 Btu/hr.ft2. ºF
(176 ºF - 131,28ºF)
= 158,2781ºF
Tube :
Pada tw = 158,2781ºF, µw = 0,412 cp (Fig. 14, Kern,1965)
= 0,9966 lb/ft.jam
𝜇
Sehingga, ∅𝑡 = (𝜇𝑤)0,14 (C.57)
= 0,9468
Shell;
Pada tw = 158,2781ºF, µw = 1,8 cp (Fig. 14, Kern,1965)
= 4,3543 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14 (C.58)
μw
0,7581 lb/ft.jam 0,14
=( )
4,3543 lb/ft.jam
= 0,7829
Menghitung Clean Overall Coefficient (Uc)
hio × ho
Uc = (C.59)
hio + ho
141,5 Btu/hr.ft2.ºF × 168,7132 Btu/hr.ft2. ºF
=
41,5 Btu/hr.ft2.ºF + 168,7132 Btu/hr.ft2. ºF
= 76,9423 Btu/hr.ft2.ºF
= 0,0036 Btu/hr.ft2.ºF
C-70
ft2 lb
0,00016 × (493.035,9058 ) 2 × 15 × 4
in2 jam.ft2
=
5,22 × 1010 × 0,1166 ft × 0,9597 × 0,9468
= 0,2108 psi
V2
= 0,033 psi (Fig. 27, Kern,1965)
2g′
V2
4×n
b. ∆Pr = × 2g' (C.62)
s
4×4
= × 0,033 psi
0,9597
= 0,2750 psi
∆Ptotal = ∆Pt + ∆Pr (C.63)
= 0,2108 psi + 0,2750 psi
= 0,4858 psi
∆Pt < 10 psi (memenuhi)
b. Shell :
1. Menentukan Faktor Friksi (f)
Res = 11.703 ft
ft2
f = 0,002 in2 (Fig. 29, Kern,1965)
C-71
= 0,0359 psi
∆Ps < 10 psi (memenuhi)
= 7,3022 in
C.16 Perhitungan Heat Exchanger (HE-02)
Fungsi :Mendinginkan larutan metil formiat dan metanol dari suhu 82,81oC
menjadi 40oC
Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
Shell Side Tube Side
ID = 21,25 inch Number and Length = 111, 15’0’’
Baffle Space = 18,0625 inch OD, BWG, pitch = 1 1/4 , 18 BWG, 19⁄16
Passes = 2 inch
Passes = 4
1. Heat balance:
Metil formiat dan metanol ,
Q = 376.039.276,51 joule/jam = 356.416,42 btu/jam
Air ,Q = 376.039.276,51 joule/jam = 356.416,42 btu/jam
2. Fluida Dingin (tube)
C-72
a. Menghitung ΔTLMTD
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1
(181,5℉ – 122℉ )- (104℉ – 86℉ )
= (181,5℉ – 122℉ )
ln (
(104℉ – 86℉ )
7,2℉ – 18℉
= 7,2℉
ln ( )
18℉
= 11,7866ºF
T1 -T2
b. R =
t2 -t1
129,2℉ -104℉
=
122℉-86℉
= 0,7 ºF
t2 - t1
c. S =
T1 - t1
C-73
122℉- 86℉
=
181,5℉-86℉
= 0,833°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,74 maka,
d. Δt = FT . LMTD
Δt = 0,74 × 11,7866℉
= 8,7221oF
Tube :
Pada t = 104ºF
μ = 0,7972 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg
356.416,42 btu/jam
=
(75 Btu/jam.ft2 .℉ )( 8,7221℉)
= 544,8466 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 1/4 in
Diameter dalam tube (ID) = 1,15 in
Jenis tube = 18 BWG
Pitch (PT) = 1 9/16 in square pitch
Panjang tube, L = 15 ft
Luas permukaan luar (a”) = 0, 3271 ft2/ft
e. Jumlah tube
A
Nt =
L . a''
544,8466 ft2
=
(15 ft)(0,3271 ft2 /ft)
= 111,0548 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 111 buah tube dengan OD tube 1 1/4 in, 19/16 in Tringular pitch untuk 4
passes (Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = Tringular pitch
C-75
= 75 Btu/jam.ft2.oF
f. Analisa Kinerja HE
½ ID × C' × B
as =
144 × PT
= 0,27 ft2
= 8.946,2218 ft
15 ft
L/D =
0,0958 ft
= 156,5217
jH = 39 (Fig. 24, Kern, 1965)
Shell :
Viskositas pada tc = 116,6ºF
μ liquid = 0,3686 cP (Fig. 14, Kern, 1965)
= 0,8917 lb/ft.jam
1.23
Dc =
12
= 0,0758 ft (Fig. 28, Kern, 1965)
D ×Gs
Res =
μ
0,0758 ft × 77.470,7092 lb/jam ft2
=
0,0.8917 lb/ft.jam
= 8.904,4133 ft
jH = 51 (Fig. 28, Kern, 1965)
e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film Coefficient
(ho)
Tube :
1
hi k c. μ 3
∅t
= jH ( D) ( k )
0,3572 Btu/jam.lbm.ft.°F
= 39 × ( ) × 1,7955 Btu/(hr) (ft2) (ºF/ft)
0,0958 ft
= 133,7427 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c
= 384,9261,0223 Btu/hr.ft2. ºF
C-79
k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k
= 123,0433 Btu/hr.ft2. ºF
hio ID
hio = × x ∅𝑡
∅t OD
384,9261 Btu/hr.ft2. ºF
= 104ºF + x
123,0433 Btu/hr.ft2. ºF+ 384,9261 Btu/hr.ft2. ºF
(116,6 ºF - 104ºF)
= 113,4813ºF
Tube :
Pada tw = 113,4813ºF, µw = 0,65 cp (Fig. 14, Kern, 1965)
= 1,5724 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
1,9284 lb/ft.jam 0,14
=( )
1,5724 lb/ft.jam
= 1,0289
Shell;
C-80
0,8917 lb/ft.jam
=( )0,14
1,2821 lb/ft.jam
= 0,9504
h. Menghitung Clean Overall Coefficient (Uc)
hio × ho
Uc =
hio + ho
126.61 Btu/hr.ft2.ºF ×329,1077 Btu/hr.ft2. ºF
=
126.61 Btu/hr.ft2.ºF +329,1077 Btu/hr.ft2. ºF
= 91,4347 Btu/hr.ft2.ºF
= 0,0060 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern, 1965)
2
f × Gt × L × n
a. ∆Pt =
5,22 × 1010 × D × s × ϕt
ft2 lb
0,00028 × (180.036,1607 ) 2 × 15 × 4
in2 jam.ft2
=
5,22 × 1010 × 1,15 × 0,0958 ft × 1,0289
= 0,0527 psi
V2
= 0,0048 psi (Fig. 27, Kern, 1965)
2g′
V2
4×n
b. ∆Pr = × 2g'
s
4×4
= × 0,0048 psi
0,0958
= 0,0382 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0527 psi + 0,0382 psi
= 0,0909 psi
∆Pt < 10 psi (memenuhi)
b. Shell :
d. Menentukan Faktor Friksi (f)
Res = 8.904,4133 ft
ft2
f = 0,0023 in2 (Fig. 29, Kern, 1965)
ft2 lb 2
0,0023 × (77.470,7092 ) × 1,7708 ft (9,9653 in)
in2 hr.ft2
= 10
5,55 × 10 × (0,1025 ft) × 0,0119 × 0,9504
= 3,8535 psi
∆Ps < 10 psi (memenuhi)
4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.3 Data Temperatur HE-03
Fluida panas Fluida Dingin Selisih
145,2°F T1 s.tinggi 122°F t2 23,2°F
104°F T2 s.rendah 86°F t1 18°F
41,2°F T1-T2 Selisih 36°F t2 - t1 -5°F
a. Menghitung ΔTLMTD
C-83
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1
23,2℉ – 18℉
= 23,2℉
ln ( )
18℉
= 20,4901ºF
𝑇 −𝑇
b. R = 𝑡1 −𝑡2
2 1
145,2℉ -104℉
=
122℉-86℉
= 1,1444 ºF
t2 - t1
c. S =
T1 - t1
122℉- 86℉
=
145,2℉-86℉
= 0,608°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,852 maka,
d. Δt = FT . LMTD
Δt = 0,852 × 20,4901℉
= 17,4576oF
Shell :
Pada T = 124,6ºF
μ = 0,3344 cP (Fig. 15, Kern, 1965)
Tube :
Pada t = 104ºF
μ = 0,7972 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg
= 538,7972 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 in
Diameter dalam tube (ID) = 0,81 in
C-85
e. Jumlah tube
A
Nt =
L . a''
538,7972 ft2
=
(18 ft)(0,2618 ft2 /ft)
= 114,3360 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 114 buah tube dengan OD tube 1 1/4 in, 19/16 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = Square pitch
b. Jumlah aliran, n = 2 aliran (passes)
c. Pitch, PT = 1 1/4 in = 1,25 ft
d. Diameter shell, ID = 19,25 in = 1,6041 ft
e. Baffle Space = 0,85 × 19,25 in = 16,3625 in
f. C = PT – OD tube
= 0,25 in
g. A Terkoreksi = Nt . L . a
= 114,3360 ×18 ft ×0,2618 ft2/ft
= 538,7972 ft2
h. Ud Terkoreksi
Q
UD =
A . t
705.458,19 btu/jam
=
538,7972 ft2x 17,4576F
= 75 Btu/jam.ft2.oF
f. Analisa Kinerja HE
C-86
= 0,22 ft2
17.239,84 lb/jam
=
0,22 ft2
= 5.875.8606 ft
18 t
L/D =
0,0675 ft
= 266,6666
jH = 29 (Fig. 24, Kern, 1965)
Shell :
Viskositas pada tc = 124,6 ºF
μ liquid = 0,3344 cP (Fig. 14, Kern, 1965)
= 0,8090 lb/ft.jam
0,99
Dc =
12
= 0,0825 ft (Fig. 28, Kern, 1965)
D ×Gs
Res =
μ
C-88
= 8.036,6079 ft
jH = 36 (Fig. 28, Kern, 1965)
0,3572 Btu/jam.lbm.ft.°F
= 29 × ( ) ×1,7955 Btu/(hr) (ft2)
0,0675 ft
(ºF/ft)
= 126,7188 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c
= 126,7188Btu/hr.ft2. ºF x 1,0405
= 131,8619 Btu/hr.ft2. ºF
Shell :
1
ℎ𝑜 k c. μ 3
∅𝑠
= jH (De) ( k )
0,0946 Btu/(hr) (ft2) (ºF/ft)
= 36 x ( )x2,5301 Btu/(hr) (ft2)
0,0825 ft
(ºF/ft)
= 394,3904 Btu/hr.ft2. ºF
1
k c. μ 3
ho = jH (D ) ( k ) 1/3 ∅𝑠
c
ID
hio = hi × x ∅𝑡
OD
= 102,64 Btu/hr.ft2. ºF x 1,0405
= 106,81 Btu/hr.ft2. ºF
Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).
g. Menghitung Temperatur Wall
ℎ𝑜
∅𝑠
tw = tc + ℎ𝑖𝑜 ℎ𝑜 (Tc - tc)
+
∅𝑡 ∅𝑠
394,3904 Btu/hr.ft2. ºF
= 104ºF + x
102,64 Btu/hr.ft2. ºF+ 394,3904 Btu/hr.ft2. ºF
(124,6 ºF - 104ºF)
= 120,2100 ºF
Tube :
Pada tw = 120,2100ºF, µw = 0,6 cp (Fig. 14, Kern,1965)
= 1,4514 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
1,928 lb/ft.jam
=( )0,14
1,4514 lb/ft.jam
= 1,0405
Shell;
Pada tw = 120,2100ºF, µw = 0,5 cp (Fig. 14, Kern,1965)
= 1,2095 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14
μw
0,8090 lb/ft.jam 0,14
=( )
1,2095 lb/ft.jam
= 0,9452
= 83,0222 Btu/hr.ft2.ºF
= 0,0012 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)
ft2 lb
0,00016 × (167.875,2728 ) 2 × 18 × 4
in2 jam.ft2
=
5,22 × 1010 × 0.675 × 0,9597 ft × 1,0405
= 0,0461 psi
2
V
V2
4×n
d. ∆Pr = × 2g'
s
4×4
= × 0,001 psi
0,09597
C-92
= 0,00833 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0461 psi + 0,00833 psi
= 0,1294 psi
∆Pt < 10 psi (memenuhi)
2. Shell :
d. Menentukan Faktor Friksi (f)
Res = 8.036,6079 ft
ft2
f = 0,002 in2 (Fig. 29, Kern,1965)
ft2 lb 2
0,002 × (78.816,1732 ) × 1,6041 ft (13,200 in)
in2 hr.ft2
=
5,55 × 1010 × (0,0825 ft) × 0,9479 × 0,9452
= 0,0641 psi
∆Ps < 10 psi (memenuhi)
= 13,200 in
4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.4 Data Temperatur HE-04
Fluida panas Fluida Dingin Selisih
289,2°F T1 s.tinggi 176°F t2 113,2°F
86°F T2 s.rendah 77°F t1 9°F
203,2°F T1-T2 Selisih 99°F t2 - t1 -104°F
a. Menghitung ΔTLMTD
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1
(289,2℉ – 176℉)- (86℉ – 77℉ )
= (289,2℉ – 176℉)
ln (
(86℉ – 77℉ )
113,2℉ – 9℉
= 113,2℉
ln ( )
9℉
C-94
= 41,1543ºF
T1 -T2
g. R =
t2 -t1
289,2℉ -86℉
=
176℉-77℉
= 2,0525 ºF
t2 - t1
h. S =
T1 - t1
176℉- 77℉
=
289,2℉-77℉
= 0,467°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,467 maka,
i. Δt = FT . LMTD
Δt = 0,467 × 41,1543℉
= 35,3927oF
Tube :
Pada t = 126,5ºF
C-95
2.971.965,85 btu/jam
=
(75 Btu/jam.ft2 .℉ )( 35,3927℉)
= 1119,6140 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 in
Diameter dalam tube (ID) = 0,81 in
Jenis tube = 18 BWG
Pitch (PT) = 1 1/4 in square pitch
Panjang tube, L = 18 ft
Luas permukaan luar (a”) = 0, 2618 ft2/ft
d. Jumlah tube
A
Nt =
L . a''
C-96
1119,6140 ft2
=
(18 ft)(0,2618 ft2 /ft)
= 237,5889 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 238 buah tube dengan OD tube 1 in, 1 1/4 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
i. Susunan tube = Square pitch
j. Jumlah aliran, n = 2 aliran (passes)
k. Pitch, PT = 1 1/4 in = 1,25 ft
l. Diameter shell, ID = 25 in = 2,08333 ft
m. Baffle Space = 0,85 × 25 in = 21,25 in
n. C = PT – OD tube
= 0,25 in
o. A Terkoreksi = Nt . L . a
= 237,5889 ×18 ft ×0,2618 ft2/ft
= 1.119,6140 ft2
p. Ud Terkoreksi
Q
UD =
A . t
2.971.965,85 btu/jam
=
1.119,6140 ft2x 35,3927 F
= 75 Btu/jam.ft2.oF
e. Analisa Kinerja HE
Analisa kinerja HE meliputi :
1) Menghitung Koefisien Overall Perpindahan Panas (U)
2) Menghitung Rd
3) Menghitung ∆P
Nt . a't
at =
144 . n
237,5889 × 0,515
=
144 × 4
= 0,2124 ft2 (Tabel.10, Kern,1965)
Shell
½ ID × C' × B
as =
144 × PT
= 0,37 ft2
0,81
=
12
= 0,0675 ft (Table. 10, Kern,1965)
Dc ×Gt
Ret =
μ
0,0675 ft × 94.373 lbm/jam ft2
=
2,154 lb/ft.jam
= 2957,3109 ft
18 t
L/D =
0,0675 ft
= 266,6666
jH = 10 (Fig. 24, Kern,1965)
Shell :
Viskositas pada tc = 187,6 ºF
μ liquid = 0,3015 cP (Fig. 14, Kern,1965)
= 0,7295 lb/ft.jam
0,99
Dc =
12
= 0,0825 ft (Fig. 28, Kern,1965)
D ×Gs
Res =
μ
0,0825 ft × 68.000,9825 lb/jam ft 2
=
0,8090 lb/ft.jam
= 7.690,1582 ft
jH = 49 (Fig. 28, Kern,1965)
= 105,3091 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c
Shell :
1
ho k c. μ 3
∅s
= jH (De) ( k )
0,0952 Btu/(hr) (ft2) (ºF/ft)
= 49 x ( ) x 1,061 Btu/(hr) (ft2) (ºF/ft)
0,0825 ft
= 60.0856 Btu/hr.ft2. ºF
k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k
= 85,3004 Btu/hr.ft2. ºF
hi ID
hio = × x ∅𝑡
∅t OD
60.0856 Btu/hr.ft2. ºF
= 126,5ºF +
85,3004 Btu/hr.ft2. ºF+ 60.0856 Btu/hr.ft2. ºF
x (187,6ºF – 126,5ºF)
= 150,3030 ºF
Tube :
Pada tw = 150,3030F, µw = 0,44 cp (Fig. 14, Kern,1965)
C-101
= 1,0643 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
2,154 lb/ft.jam
=( )0,14
1,0643 lb/ft.jam
= 1,1037
Shell;
Pada tw = 150,3030ºF, µw = 0,8 cp (Fig. 14, Kern,1965)
= 1,9352 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14
μw
0,7295 lb/ft.jam 0,14
=( )
1,9352 lb/ft.jam
= 0,8723
= 33,6697 Btu/hr.ft2.ºF
= -0,0163 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)
Ret = 2.957,3109 ft
ft2
f = 0,00038 (Fig. 26, Kern,1965)
in2
= 0,0311 psi
V2
= 0,001 psi (Fig. 27, Kern,1965)
2g′
V2
4×n
b. ∆Pr = × 2g'
s
4×4
= × 0,001 psi
1,0073
= 0,0079 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0311 psi + 0,0079 psi
= 0,0390 psi
∆Pt < 10 psi (memenuhi)
Shell :
1. Menentukan Faktor Friksi (f)
Res = 7.690,1582 ft
ft2
f = 0,0026 in2 (Fig. 29, Kern,1965)
ft2 lb 2
0,0026 × (68.000,9825 ) × 2,0833 ft (10,1647 in)
in2 hr.ft2
= 10
5,55 × 10 × (0,0825 ft) x 1,0119 × 0,8923
= 0,0629 psi
∆Ps < 10 psi (memenuhi)
= 10,1647 in
Input CD-01
RB-01
Gambar C.1 Menara Distilasi D-01
2. Struktur kuat
3. Tahan terhadap korosifitas tinggi
C. Kondisi Operasi
Langkah-langkah perhitungannya adalah sebagai berikut:
1. Menentukan kondisi operasi atas dan bawah menara distilasi
2. Menentukan volatilitas rata-rata
3. Mengecek pemilihan light key component (LK) dan heavy key component
(HK) dengan persamaan Shira’s et. Al. pada Rm
KLK
α= (Coulson, 1983) (C.66)
KHK
αtop +αbottom
αAvg = (Coulson, 1983) (C.67)
2
4. Menghitung jumlah plate minimum dengan persamaan Fenske (R. Van
Wingkle;eg : 5.118 ; p 236)
Log[(XLK /XHK )D x (XHK /XLK )B ]
Nm= (Coulson, 1983) (C.68)
Log(αlk )
9366,52 11379,36
Total 20745,88 1,00 1,00
20745,88
Keterangan:
A, B, C, D, E = konstanta
P = tekanan uap komponen (pa)
T = tekanan (K)
Konstanta untuk tiap-tiap komponen dapat dilihat pada tabel berikut:
Tabel C.6 Konstanta Tekanan Uap
Komponen A B C D E
HCOOCH3 77,184 -5606,01 -8,392 7,85x10-6 2
H2O 73,649 -7258,2 -7,3037 4,17 x10-6 2
HCOOH 50,323 -5378,2 -4,203 3,47 x10-6 2
CH3OH 81,77 -6878 -8,7078 7,19 x10-6 2
Sumber: (Carl L. Yaws,2005)
Pemilihan light key dan heavy key tepat karena dari hasil perhitungan diatas metil
formiat dan asam formiat terdistribusi
NM = 10,718
RM = 1,429
m
Log = 0,9
p
m
=9
p
m=9p
N = m+p
12 = 9 p+p
p =1
m = N-p
=12-1
=11
⅀yD
ρliquid = yD (C.78)
⅀
ρi
= 824,156 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
ρuap = (BM x P) /RT (C.79)
C-112
⅀yD
ρuap = yD (C.80)
⅀
ρi
= 1,149 kg/m3
Densitas pada suhu bawah (416,05 K)
Tabel C.12 Hasil Perhitungan Densitas Liquid
Komponen BM Bottom xB, B ρ Liquid xB/ρi
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 0,00 0,00 975 4,47 x 10-11
H2O 18,02 308,17 0,07 994,1 6,68 x 10-5
HCOOH 46,03 11063,19 0,93 1226,47 7,60 x 10-4
CH3OH 32,04 8,00 0,00 810 1,20 x 10-6
⅀xB
ρliquid = xB
⅀
ρi
= 1207,14 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
ρ uap = (BM x P) /RT
C-113
⅀xB
ρuap = xB
⅀
ρi
= 1,221 kg/m3
2. Menghitung Tegangan Permukaan
Tegangan permukaan dihitung dengan persamaan Sudgen:
Pch (𝜌𝐿−𝜌𝑣) 4
σ=[ ] x 10-12 (Coulson, 1983) (C.81)
𝑀
Keterangan :
σ = Tegangan permukaan (dyne/cm)
Pch = Sudgen’s parachor
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
M = Berat molekul (kg/kmol)
Tabel C.14 Data untuk menentukan Pch (Coulson, 1983)
Atom, group or bond Contribution Atom, group or bond Contribution
C 4,8 Si 25,0
H 17,1 Al 38,6
H in (OH) 11,3 Sn 57,9
O 20,0 As 50,1
O2 60,0 Double bond: terminal
N 12,5 2,3 position 23,2
C-114
Keterangan :
FLV = Liquid-vapor flow factor
LW = Laju alir massa cairan (Kg/h)
VW = Laju alir massa uap (kg/h)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
9366,52 1,149
FLV, top = √
9366,52 824,156
= 0,037
Untuk tray spacing = 0,4 m dan FLV = 0,037 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 top:
σ top 0,2
K1’ top = K1 [ ] (Coulson, 1983) (C.83)
0,02
0,00004 0,2
K1’ top = 0,065 [ 0,02
]
C-116
= 0,018
9366,52 1,221
FLV, bottom = 9366,52
√1207,14
= 0,031
Untuk tray spacing = 0,4 m dan FLV = 0,031 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 bottom:
σ bottom 0,2
K1’ bottom = K1 [ ] (Coulson, 1983) (C.84)
0,02
0,0000657 0,2
K1’ bottom = 0,06 [ ]
0,02
= 0,019
Keterangan :
uf = Kecepatan flooding (m/s)
K1 = Konstanta
C-117
kg kg )
(824,156 - 1,149
uf, top = 0,018 √ m3 m3
1,149 kg/m3
= 0,150 m/s
Kecepatan flooding bagian bawah (bottom) :
kg kg )
(1207,14 - 1,221
uf, bottom = 0,019 √ m3 m3
1,221 kg/m3
= 0,096
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding (Coulson,
1983) untuk perancangan diambil uv = 80% uf.
Kecepatan uap pada bagian atas (top) :
uv, top = 80% x uf top (C.86)
= 80% x 0,150 m/s
= 0,120 m/s
Kecepatan uap pada bagian bawah (bottom) :
uv, bottom = 80% x uf bottom (C.87)
= 80% x 0,096 m/s
= 0,076 m/s
Keterangan :
Qv = Laju alir volumetrik maksimum (m3/s)
Vw = Laju alir massa uap (kg/s)
ρv = Densitas uap (m3/s)
Laju alir volumetrik maksimum bagian atas (top) :
9.366,52 kg/h
Qv, top =
1,149 kg/m3 x 3600 sec/h
C-118
= 0,226 m3/s
Laju alir volumetrik maksimum bagian bawah (bottom) :
9.366,52 kg/h
Qv, bottom =
1,221 kg/m3 x 3600 sec/h
= 0,212 m3/s
= 1,883 m2
Luas area netto bagian bawah (bottom) :
0,212 m3/s
An, bottom =
0,076 m/s
= 2,079 m2
7. Menentukan Luas Penampang Lintang Menara :
An
Ac = (C.90)
1-Ad
Luas penampang downcomer (Ad) = 20% dari luas keseluruhan, sehingga :
1,883 m2
Ac, top =
(1 – 0,2)
= 2,354 m2
2,079 m2
Ac, bottom =
(1 – 0,2)
= 2,559 m2
C-119
4. Ac
Menghitung diameter menara : Dc =√
π
4. 2,534 m2
Dc, top =√
3,14
= 1,731 m
Diameter menara bagian bawah (bottom)
4. 2,599 m2
Dc, bottom =√
3,14
= 1,819 m
9. Menentukan Jenis Aliran (Flow Pattern)
Kecepatan volumetris maksimum cairan :
Lw, B
QL.B = (C.91)
ρL,B
11.379,36 kg/jam
= kg x
1207,14 3600 sec/jam
m3
= 0,026 m3/s
Keterangan :
QL.bot = laju alir volumetrik bagian bottom (m3/s)
Lw = laju alir massa cairan bagian bottom (kg/s)
ρL = densitas cairan bagian bottom (kg/m3)
dari fig 11.28 (Coulson, 1983) untuk QL.B = 0,0026 m3/s maka jenis alirannya
adalah cross flow (single pass).
a. Perancangan Tray
Tray spacing = 0,4 m
Diameter menara, DC = 1,819 m
Luas menara, Ac = 2,984 m2
Luas Downcomer, Ad = 0,358 m2
Luas netto, An = 2,626 m2
Luas aktif, Aa = 2,268 m2
C-120
Untuk menara distilasi ini digunakan bahan carbon steel, sehingga tebal plate yang
digunakan = 5 mm. (Coulson vol 6 1ed p465, 1983).
keterangan :
Lw = liquid flow rate, kg/s
Iw = weir length, m
ρL = densitas liquid, kg/m3
how = weir crest, mm liquid
1. Menara Bagian Atas
0,260 kg/s
how max = 750 ( )
1207,14 kg/m3 x 1,485 m
= 4,735 mm liquid
0,208 kg/s
how min = 750 ( )
1207,14 kg/m3 x 1,485 m
= 3,788 mm liquid
Pada minimum rate, (ho + how) = 54,735 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,4
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh = (C.93)
(ρv)1/2
C-122
Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,4 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,793 m/s
(1,149 kg/m3)1/2
= 3,233 mm liquid
2,081 kg/s
how min = 750 ( )
824,156 kg/m3 x 1,485 m
= 2,586 mm liquid
Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,5 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,544 m/s
(1,121 kg/m3)1/2
hd = 1,436 mm liquid
Keterangan :
Uh = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Qv.bottom = Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = Densitas uap bagian bottom (kg/m3)
ρL = Densitas liquid bagian bottom (kg/m3)
C0 = Orifice coefficient
hd = Dry Plate drop (mm)
Residual Head
12,5 x 103
hr =
ρL
= 15,167 mm liquid
Keterangan :
hr = residual head (mm)
ρL = Densitas liquid bagian bottom (kg/m3)
C-124
Keterangan :
hr = residual head (mm)
hd = Dry Plate drop (mm)
hw = tinggi weir (mm)
how = tinggi weir liquid (mm cairan)
hT = total plate pressure drop (mm liquid)
Check Entrainment
Actual Percentage Flooding For Design Area
Entrainment dihitung dari %flooding, dengan persamaan :
uv
%flooding = x 100% (C.100)
uf
Layout Tray
Digunakan cartridge-type construction dengan 50 mm unperforated strip around
tray edge dan 50 mm wide calming zones. Dari fig.11.32 (Coulson, 1983, hal.465),
untuk lw/Dc = 0,76, maka : θc = 102°
- Derajat tray edge
α = 180-θc
α =180 – 102 = 78°
- Panjang rata-rata unperforated edge strips
θ
Lm = (Dc - hw) x 3,14 (180) (C.101)
78
Lm = (1,95 - 0,05) x 3,14 ( )
180
Lm = 2,585 m
C-128
0,05 2
Aoh = 3,14
4
Aoh = 19,625 mm2
Aoh = 1,9625 x 10-5 m2
Jumlah Lubang
Ah
= (C.107)
Aoh
C-129
0,068
=
1,9625 x 10−5 m2
= 3467 lubang
a. Spesifikasi Tray
Diameter menara, DC = 1,819 m
Diameter lubang, dh = 3 mm = 0,003 m
Hole pitch = 0,0125 m
Jumlah hole = 3467 lubang
Turn down ratio = 80%
Tray spacing = 0,4 m
Tray thickness = 0,003 m
Panjang weir = 1,4859 m
Tinggi weir = 0,05 m
Total pressure drop = 763,942706 pa
G. Mechanical Design
A. Head Menara
1. Menentukan Tebal Dinding dan Head Menara
OD
OA b=depth
icr of dish
A
sf B
ID
t
a
r
W
1
4
3 r
icr (C.109)
W = 1,723 in
C-131
thead = 0,885 in
Untuk tebal head 1,75 in,dari tabel 5,8 Brownell and Young maka:
Sf = 1,5 – 4,5 in
Diambil sf = 3,5 in
ID 2
b = rc -√(rc -icr )2 - ( -icr ) (C.110)
2
76,77 in 2
b = 30 in -√(30 in-1,98 in)2 - ( -1,98 in)
2
b = 51 in
= 1,3 m
= 28,02 in
= 0,712 m
=√36,412 -28,022
= 23,250 in
= 0,59 m
5. Tinggi Menara
Data perhitungan:
Diameter kolom, Dc = 1,819 m
Luas kolom, Ac = 2,985 m2
Volume head = 0,000049 (D3)
= 0,000049 (1,95)3
= 0,0003633 m3
π
Volume head pada sf = x ID2 x sf (C.115)
4
HL = 4,53 m
20.745,88 kg/jam
=
984,376 kg/m3
= 21,075 m3/jam
= 5,85 x 10-3 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37 (C.124)
= 352,8 x 5,7200,52 x (0,441 x 10-3)0,03 x 984 30,37
= 54,314 mm
= 3,277 in
9.366,52 kg/jam
=
822,667 kg/m3
= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
9.366,52 kg/jam
=
822,667 kg/m3
= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
11.379,36 kg/jam
=
1205,59 kg/m3
= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
11.379,36 kg/jam
=
1205,59 kg/m3
= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
Direncanakan manhole dipasang pada bagian samping sisi kolom sebanyak 2 buah
dengan ukuran standar 20 in berdasarkan rekomendasi API standar 12 C. Maka
konstruksi manhole berdasarkan rekomendasi API standar 12 C (Brownell and
Young, appendix F item 3 dan 4) dengan spesifikasi:
Diameter Manhole (ID) = 20 in
Ketebalan cover plate = 5/8 in
Bolting-flange thickness after finishing = ½ in
Dimensi manhole 20 in berdasarkan rekomendasi API Standard 12 C:
Ketebalan shell manhole = 0,3125 in
Ukuran Fillet Weld A = 0,1875 in
Ukuran Fillet Weld B = 0,3125 in
Approx Radius ® = 5/8 in
Length of Side (L) = 45 in
Width of Renforcing Plate (W) = 54 in
Max Diameter of Hole in Shell = 24,5 in
Inside Diameter of Manhole = 20 in
Diameter Bolt Circle (DB) = 26,25 in
Diameter of Cover Plate (DC) = 28,75 in
C-140
Input CD-02
RB-02
Gambar C.8 Menara Distilasi D-02
D. Kondisi Operasi
Langkah-langkah perhitungannya adalah sebagai berikut:
1. Menentukan kondisi operasi atas dan bawah menara distilasi
2. Menentukan volatilitas rata-rata
3. Mengecek pemilihan light key component (LK) dan heavy key component
(HK) dengan persamaan Shira’s et. Al. pada Rm
KLK
α= (Coulson, 1983)
KHK
αtop +αbottom
αAvg = (Coulson, 1983)
2
1546,65 7819,87
Total 9366,52 1,00 1,00
9366,52
Keterangan:
A, B, C, D, E = konstanta
P = tekanan uap komponen (pa)
T = tekanan (K)
Konstanta untuk tiap-tiap komponen dapat dilihat pada tabel berikut:
Tabel C.18 Konstanta Tekanan Uap
Komponen A B C D E
HCOOCH3 77,184 -5606,01 -8,392 7,85x10-6 2
H2O 73,649 -7258,2 -7,3037 4,17 x10-6 2
HCOOH 50,323 -5378,2 -4,203 3,47 x10-6 2
CH3OH 81,77 -6878 -8,7078 7,19 x10-6 2
Sumber: (Carl L. Yaws,2005)
C-143
αD = 1,871
αB = 1,577
αtop +αbottom
αAvg = (Eq 8.11 Ludwig, 1980)
2
1,871 + 1,577
αAvg =
2
αAvg = 1,724
B. Menentukan stage minimum
Dengan menggunakan metode Fenske
Log[(XLK /XHK )D x (XHK /XLK )B ]
NM =
Log(αAvg )
NM = 4,794
C. Mencari Refluks ratio minimum
1 Xd LK α(1-Xd LK)
RM = [ - ]
α-1 XF LK (1-XF LK)
RM = 0,809
R operasi berkisar antara 1,2 – 1,5 Rm (Geankoplis, 1993)
Diambil Roperasi = 1,2 x Rm
= 1,2 x 0,809
= 0,9708
C-145
Rm
= 0,447
Rm +1
Nm = 4,794
4,794
N = 0,4
N = 11
N actual = 11 + 1 (stage reboiler)
= 12
C-146
E. Feed Location
Feed location ditentukan dengan menggunakan metode Kirkbride.
m B X (X ) 2
Log p = 0,206 Log {D ( XHK ) [(X LK )B ] } (vol.6 Eq 11.62 Coulson,1983)
LK F HK D
m
Log = 0,9
p
m
=9
p
m=9p
N = m+p
11 = 9 p+p
p =1
m = N-p
=11-1 =10
= 963,194 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
C-147
R = 8.314,34 Pa/kmol.K
ρuap = (BM x P) /RT
= 2,280 kg/m3
= 811,36 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
C-148
⅀xB
ρuap = xB
⅀
ρi
= 1,165 kg/m3
2. Menghitung Tegangan Permukaan
Tegangan permukaan dihitung dengan persamaan Sudgen:
Pch (𝜌𝐿−𝜌𝑣) 4
σ=[ ] x 10-12 (Coulson, 1983)
𝑀
Keterangan :
σ = Tegangan permukaan (dyne/cm)
Pch = Sudgen’s parachor
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
M = Berat molekul (kg/kmol)
Tabel C.26 Data untuk menentukan Pch (Coulson, 1983)
Atom, group or bond Contribution Atom, group or bond Contribution
C 4,8 Si 25,0
H 17,1 Al 38,6
H in (OH) 11,3 Sn 57,9
O 20,0 As 50,1
O2 60,0 Double bond:terminal
C-149
Keterangan :
FLV = Liquid-vapor flow factor
LW = Laju alir massa cairan (Kg/h)
VW = Laju alir massa uap (kg/h)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
1546,65 2,280
FLV, top = 1546,65
√963,194
= 0,048
Untuk tray spacing = 0,3 m dan FLV = 0,048 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 top:
σ top
K1’ top = K1 [ 0,02 ]0,2 (Coulson, 1983)
0,00008 0,2
K1’ top = 0,065 [ ]
0,02
= 0,021
1546,65 1,165
FLV, bottom = 1546,65
√811,36
C-151
= 0,037
Untuk tray spacing = 0,3 m dan FLV = 0,037 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 bottom:
σ bottom 0,2
K1’ bottom = K1 [ ] (Coulson, 1983)
0,02
0,00003 0,2
K1’ bottom = 0,06 [ ]
0,02
= 0,016
Keterangan :
uf = Kecepatan flooding (m/s)
K1 = Konstanta
C-152
kg kg )
(963,194 – 2,280
uf, top = 0,021 √ m3 m3
2,280 kg/m3
= 0,150 m/s
kg kg )
(811,36 - 1,165
uf, bottom = 0,016 √ m3 m3
1,165 kg/m3
= 0,096
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding (Coulson, 1983)
untuk perancangan diambil uv = 80% uf.
Kecepatan uap pada bagian atas (top) :
uv, top = 80% x uf top
Keterangan :
Qv = Laju alir volumetrik maksimum (m3/s)
Vw = Laju alir massa uap (kg/s)
ρv = Densitas uap (m3/s)
Laju alir volumetrik maksimum bagian atas (top) :
1546,65 kg/h
Qv, top = 2,280 kg/m3 x 3600 sec/h
= 0,114 m3/s
C-153
= 0,223 m3/s
12. Menentukan Luas Area Netto Untuk Kontak Uap-Cair
Qv
An = uv
Keterangan :
An = Luas Area Netto (m2)
Qv = Laju alir volumetrik (m3/s)
uv = Kecepatan uap (m/s)
= 1,949 m2
Luas area netto bagian bawah (bottom) :
0,223 m3/s
An, bottom = 0,076 m/s
= 2,079 m2
13. Menentukan Luas Penampang Lintang Menara :
An
Ac = 1-A
d
= 2,436 m2
2,079 m2
Ac, bottom = (1 – 0,2)
= 2,599 m2
4. Ac
Menghitung diameter menara : Dc =√
π
C-154
4. 2,436 m2
Dc, top =√
3,14
= 1,861 m
Diameter menara bagian bawah (bottom)
4. 2,599 m2
Dc, bottom =√
3,14
= 1,95 m
15. Menentukan Jenis Aliran (Flow Pattern)
Kecepatan volumetris maksimum cairan :
Lw, B
QL.B =
ρL,B
7819,87 kg/jam
= kg x
811,36 3600 sec/jam
m3
= 0,003 m3/s
Keterangan :
QL.bot = laju alir volumetrik bagian bottom (m3/s)
Lw = laju alir massa cairan bagian bottom (kg/s)
ρL = densitas cairan bagian bottom (kg/m3)
dari fig 11.28 (Coulson, 1983) untuk QL.B = 0,0026 m3/s maka jenis alirannya
adalah cross flow (single pass).
b. Perancangan Tray
Tray spacing = 0,3 m
Diameter menara, DC = 1,95 m
Luas menara, Ac = 2,984 m2
Luas Downcomer, Ad = 0,358 m2
Luas netto, An = 2,626 m2
Luas aktif, Aa = 2,268 m2
Luas hole, Ah = 0,068 m2
Dari figure 11.31 (Coulson,1983), untuk Ad/Ac = 0,12 maka:
C-155
Iw/Dc = 0,762
Panjang Weir, Iw = 0,762 x Dc
= 1,485 m
Tebal Tray
Untuk bahan carbon steel tebal plate yang digunakan adalah 5 mm (3/16 in),
sedangkan untuk bahan stainless steel tebal plate yang digunakan adalah 3 mm.
C-156
Untuk menara distilasi ini digunakan bahan carbon steel, sehingga tebal plate yang
digunakan = 5 mm. (Coulson vol 6 1ed p465, 1983).
Pemeriksaan Weeping Rate
9.366,52 kg/jam
Lwmax = = 0,260 kg/s
3600 s/jam
keterangan :
Lw = liquid flow rate, kg/s
Iw = weir length, m
ρL = densitas liquid, kg/m3
how = weir crest, mm liquid
3. Menara Bagian Atas
0,260 kg/s
how max = 750 ( )
1207,14 kg/m3 x 1,485 m
= 4,051 mm liquid
0,208 kg/s
how min = 750 ( )
1207,14 kg/m3 x 1,485 m
= 3,848 mm liquid
Pada minimum rate, (ho + how) = 54,051 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,4
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh =
(ρv)1/2
Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
C-157
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,4 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,793 m/s
(1,149 kg/m3)1/2
= 3,233 mm liquid
2,081 kg/s
how min = 750 ( )
824,156 kg/m3 x 1,485 m
= 2,586 mm liquid
Pada minimum rate, (ho + how) = 53,233 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,5
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh =
(ρv)1/2
Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,5 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,544 m/s
(1,121 kg/m3)1/2
hd = 1,436 mm liquid
Keterangan :
Uh = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Qv.bottom = Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = Densitas uap bagian bottom (kg/m3)
ρL = Densitas liquid bagian bottom (kg/m3)
C0 = Orifice coefficient
hd = Dry Plate drop (mm)
Residual Head
12,5 x 103
hr = ρL
= 12,977 mm liquid
Keterangan :
hr = residual head (mm)
ρL = Densitas liquid bagian bottom (kg/m3)
Total Plate Pressure Drop
hT = hd + (hw + how) + hr
= 67,649 mm liquid
Keterangan :
hr = residual head (mm)
C-159
Lw
hdc = 166 [ρ ]2
L Aap
Check Entrainment
Actual Percentage Flooding For Design Area
Entrainment dihitung dari %flooding, dengan persamaan :
uv
%flooding = u x 100%
f
Layout Tray
Digunakan cartridge-type construction dengan 50 mm unperforated strip around
tray edge dan 50 mm wide calming zones. Dari fig.11.32 (Coulson, 1983, hal.465),
untuk lw/Dc = 0,76, maka : θc = 102°
- Derajat tray edge
α = 180-θc
α =180 – 102 = 78°
- Panjang rata-rata unperforated edge strips
θ
Lm = (Dc - hw) x 3,14 ( )
180
78
Lm = (1,95 - 0,05) x 3,14 ( )
180
Lm = 2,585 m
- Luas unperforated edge strip (Aup)
Aup = hw . Lm
= 0,05 (2,5852)
= 0,129 m2
- Luas calming zone (Acz)
Acz = 2 x hw x (lw - (2 x hw)
= 2 x 0,129 x (1,482 m) – 2 x 0,129)
= 0,138 m2
- Total area perforated (Ap)
Ap = Aa – (Aup + Acz)
= 2,269 m2 – (0,129 m2 + 0,138 m2)
= 2,001 m2
Ah 0,068
=
Ap 2,001
C-163
0,05 2
Aoh = 3,14 4
= 3467 lubang
b. Spesifikasi Tray
Diameter menara, DC = 1,95 m
Diameter lubang, dh = 5 mm = 0,005 m
Hole pitch = 0,0125 m
Jumlah hole = 3467 lubang
Turn down ratio = 80%
Tray spacing = 0,3 m
Tray thickness = 0,003 m
Panjang weir = 1,4859 m
Tinggi weir = 0,05 m
C-164
G. Mechanical Design
A. Head Menara
1. Menentukan Tebal Dinding dan Head Menara
OD
OA b=depth
icr of dish
A
sf B
ID
t
a
r
Keterangan:
th = tebal head (in)
icr = inside corner radius (in)
r = radius of dish (in)
sf = straight flange (in)
OD = diameter luar (in)
ID = diameter dalam (in)
b = depth of dish (in)
OA = tinggi head (in)
3 atm.0,975 m
tsilinder = + 0,002 M
2 (932,2297 atm)(0,85) - 0,6 x 3 atm
W
1
43 r
icr
W = 1,723 in
thead = 0,885 in
thead = 1,75 in
C-166
Untuk tebal head 1,75 in,dari tabel 5,8 Brownell and Young maka:
Sf = 1,5 – 4,5 in
Diambil sf = 3,5 in
ID 2
b = rc -√(rc -icr )2 - ( 2 -icr )
76,77 in 2
b = 30 in -√(30 in-1,98 in)2 - ( 2 -1,98 in)
b = 51 in
= 1,3 m
AC = √AB2 -BC2
=√36,412 -28,022
= 23,250 in
= 0,59 m
C-167
5. Tinggi Menara
Data perhitungan:
Diameter kolom, Dc = 1,95 m
Luas kolom, Ac = 2,985 m2
Volume head = 0,000049 (D3)
= 0,000049 (1,95)3
= 0,0003633 m3
π
Volume head pada sf = 4 x ID2 x sf
Q = 11,222 m3/jam
Q = 0,187 m3/menit
Waktu tinggal dibawah plate terakhir: 5 – 10 menit (Ulrich,1984). Waktu
tinggal cairan dipilih = 5 menit.
Vcairan = Q x waktu tinggal
= 0,187 m3/menit x 5 menit
= 0,935 m3
Tinggi cairan dalam shell (HL):
π
Vcairan = 4 Dc2 HL
HL = 4,53 m
C-168
= 21,075 m3/jam
= 5,85 x 10-3 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 5,7200,52 x (0,441 x 10-3)0,03 x 984 30,37
= 54,314 mm
= 3,277 in
C-169
9.366,52 kg/jam
=
822,667 kg/m3
= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
C-170
= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
C-171
= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
C-172
= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
C-173
Direncanakan manhole dipasang pada bagian samping sisi kolom sebanyak 2 buah
dengan ukuran standar 20 in berdasarkan rekomendasi API standar 12 C. Maka
konstruksi manhole berdasarkan rekomendasi API standar 12 C (Brownell and
Young, appendix F item 3 dan 4) dengan spesifikasi:
Diameter Manhole (ID) = 20 in
Ketebalan cover plate = 5/8 in
Bolting-flange thickness after finishing = ½ in
Dimensi manhole 20 in berdasarkan rekomendasi API Standard 12 C:
Ketebalan shell manhole = 0,3125 in
Ukuran Fillet Weld A = 0,1875 in
Ukuran Fillet Weld B = 0,3125 in
Approx Radius ® = 5/8 in
Length of Side (L) = 45 in
Width of Renforcing Plate (W) = 54 in
Max Diameter of Hole in Shell = 24,5 in
Inside Diameter of Manhole = 20 in
Diameter Bolt Circle (DB) = 26,25 in
Diameter of Cover Plate (DC) = 28,75 in
C-175
1
ρ mix = Xi/ρi (C.125)
1
ρ mix = 0,00102
= 984,375955 kg/m3
= 61,45262 lb/ft3
Laju alir massa
Laju alir volumetrik (V1) = Densitas campuran (C.126)
45.736,78 lb/jam
= 61,45262 lb/ft3
= 744.2607961 ft3/jam
Laju alir mol M-formiat (FAO) = 267,25 kgmol/jam = 594,699935 lbmol/jam
C-177
FAo
Konsentrasi awal M-formiat (CAo) = (C.127)
V1
594,699935 lbmol/jam
= 744.2607961 ft3/jam
= 0,791645282 lbmol/ft3
B. Menentukan Waktu Tinggal Reaktor
Perhitungan waktu tinggal, τ
τ = Vr / V1 (Perry, 1999) (C.128)
713,6399219 ft3
=
744.2607961 ft3/jam
= 0,9499 jam
Volume bahan masuk (Vr) = τ x V umpan
= 0,9499 jam x 20,745 ft3/jam
= 19,70805 m3
= 713,6399 ft3
Faktor keamanan = 20 %
= 20% x Vm
=0,2 x 713,6399219 ft3
= 141,4057 ft3
Volume total = Vf + Vfk (C.129)
= 707,0286 ft3 + 141,4057 ft3
= 848,4344 ft3
3 8 x 848,4344 ft3
Dt = √ 3 x 3,14
= 8,965 ft
=107,580534 in
R = 4,482522 ft
= 53,7902 in
Tinggi tangki, H;
H = (3/2) Dt
= (3/2) 8,965 ft
= 13,44756 ft
= 164,371 in
= 99,27048 ft3
Volume cairan dalam Shell (Vc);
(Vc) = Vt – 2Vh (C.132)
= 848,4344 ft3– 2 (99,27048 ft3)
= 659,8934 ft3
Tinggi cairan (h);
659,8934 ft3
=
3,14 x (8,965 ft )2 /4
= 10,45921 ft
Perhitungan Tekanan Desain
Pdesain = Phidrostatik + Poperasi (C.134)
C-179
Tekanan hidrostatik :
g
ρ. h.
gc
Phidrostatik = (C.135)
144
Keterangan :
g : Percepatan gravitasi = 32,174 ft/det2
gc : Faktor konversi percepatan gravitasi = 32,1740 g.cm/gf.det2
lb
61,45262 x 10,45921 ft x 1
ft3
=
144
= 4,4635 psia
Poperasi = 3 atm = 44,1psia
Pdesain = 44,1 psia + 4,4635 psia
= 48,5635 psia
Perhitungan Tebal Sheel, t
Bahan yang digunakan adalah stainless steel, dimana :
- Allowable Working Stress (S) = 12650 psia
- Efisiensi sambungan (E) = 0,8
- Faktor korosi = 0,13 – 0,5 mm/ tahun
- Diambil = 0,01 in/ tahun
- Umur alat = 20 tahun
PR
t = SE−0,6 P +(c . n) dimana R = D/2 (Mc Cetta, 1993) (C.136)
48,5635 psia x 53,7902 in
= (12650 psia x 0,8)− 0,6 x48,5635 psia + (0,01 in/tahun x 20 tahun)
= 0,458872 in
Dari tabel 5.4, Brownell, 1979, dipilih tebal tangki standar ½ in.
C-180
OD
OA
b
icr
ID
B A
Sf
a
C
a = ID /2 = 107,5805 in /2 = 53,7902 in
ID
AB = – icr = 53,7902 in - 1,5 = 52,2902 in
2
F. Perancangan Pengaduk
Digunakan jenis six pitched blade turbine. Karena dapat digunakan untuk
campuran berviskositas < 10.000 cp ( Geankoplis 1993,hal 143). Pengaduk didesain
dengan standar sebagai berikut :
C-182
Da : Dt =1:4
W : Dt = 1 : 20
C : Dt =1:4
L : Dt =1:4
Dimana :
Da = Diameter pengaduk
Dt = Diameter tangki
W = Lebar daun pengaduk (blade)
C = Jarak pengaduk dari tangki dasar
L = Panjang daun pengaduk (blade)
J = Lebar baffle
Jadi :
Diameter pengaduk (Da) = 1/3 x Dt = 1/3 x 8,96504 ft = 2,98834 ft
Lebar daun pengaduk (W) = 1/5 x Da = 1/5 x 2,98834 ft = 0,1494 ft
Jarak pengaduk dari tangki dasar (C) = ¼ x Dt = ¼ x 8,96504 ft = 2,2412 ft
Panjang daun pengaduk (L) = ¼ x Dt = ¼ x 8,96504 ft = 2,2412 ft
Diameter batang pengaduk (Dd) = 2/3 Da = 2/3 x 2,98834 ft = 1,9922 ft
Lebar baffle (J) = 0,17 x Dt = 0,17 x 8,96504 ft = 0,508 ft
Tebal baffle = 1/5 x Da = 1/5 x 2,98834 ft = 0,59766 ft
Jarak baffle dari dasar tangki (offset 1) = ½ x Da = ½ x 2,98834 f = 1,4941 ft
Jarak baffle dari permukaan cairan ( offset 2) = 1/6 x J = 1/6 x 0,508 ft = 0,08466 ft
C-183
Rasio H/D maksimum untuk penggunaan 1 buah impeller adalah 1,5 untuk
viskositas liquid <25000 cP dan rasio H/D = 1,5 maka jumlah impeller yang
digunakan sebanyak 1 buah. Kecepatan putaran motor standar yang tersedia secara
komersil adalah 37, 45, 56, 68, 84, 100, 125, 155, 190 dan 320 rpm (Walas,
1990).
N = 125 rpm = 2 rps
Bilangan Reynold,
ρ (Da)2 N
NRe = (C.141)
µ
lb
61,45262 x (2,98834 ft)2 x 2 rps
ft3
=
0,4416127 cP
= 2.485,3709
Dari gambar 9-13 mc cabe1jilid 1 untuk kurva A diperoleh angka daya,
Np =2
2. Kebutuhan Daya Teoritis :
Np ρN3 D5a
P = (C.142)
gc
lb
2 x 61,45262 x (2)3 .((2,98834 ft))5
ft3
P =
32,174
= 7.283,0168 ft.lbf/s
= 7.283,0168 ft.lbf/s / 2.571,875651
= 2,93035 hp
Efisiensi motor = 80 %
2,93035 hp
Motor yang digunakan =
0,80
= 3,66294 hp
digunakan secara luas, mudah dalam pengelasan dan biaya awalnya rendah. Data
perancangan:
Tekanan desain (p) = 48,64052991 psia
Temperatur desain = 80 0C
Material flange = Stainless steel SA 283 GRADE C
Bolting steel = SA 193 Grade B7 (Brownell and Young, 1959)
Material gasket = Asbestos composition, stainless steel
(Gambar12.11, Brownell and Young, 1959)
Diameter luar shell (B) = 110,3642 in = 9,19702 ft
Ketebalan shell = 0,463757671 in
Diameter dalam shell = 109,4367 in
Tegangan dari material flange = 18.750 psi
Tegangan dari bolting material (fb) = 20.000 psi
Keterangan:
P = tekanan desain (psi)
do = diameter luar gasket (in)
di = diameter dalam gasket (in)
C-186
Do = 107,5805 in x 1,000333862
= 108,5345 in
Lebar gasket minimum
do-di
N = (C.144)
2
108,5345 in - 107,5805 in
=
2
= 0,018117 in
Keterangan :
N = Lebar gasket minimum (in)
do = Diameter luar gasket (in)
di = Diameter dalam gasket (in)
Digunakan gasket dengan lebar standar 0,25 in (Gambar 12.12, Brownell and
Young,1959).
Diameter gasket rata-rata (G) :
G = di + lebar gasket (C.145)
= 107,5805 in + 0,25 in
= 108,7482 in
Dari Fig 12.12 B & Y, kolom 1, tipe 1.a, didapat :
bo = N/2 (C.146)
=0,25/2
= 0,125 in
C-187
= 0,161401361 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas) (C.148)
= 3,9 x (0,161401361 )0,45 x (48,63)0,13
= 2,930 in
Dipilih untuk nozzle pemasukan umpan menggunakan pipa dengan diameter
standar: 3 in
2. Nozzle umpan air
Laju alir umpan masuk H2O = 4645,73 kg/jam = 2,845 lb/s
Densitas umpan = 62,3022 lb/ft3
Laju Alir
Debit umpan =
Densitas
2,845 lb/s
=
62,3022 lb/ft3
= 0,045664 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas)
= 3,9 x (0,045664)0,45 x (48,63)0,13
= 1,6640 in
Dipilih untuk nozzle pemasukan umpan menggunakan pipa dengan diameter
standar: 2 in
3. Nozzle keluaran reaktor
Laju alir umpan masuk = 45.736,7774 lb/jam =12,7046 lb/s
Densitas umpan = 61,4526 lb/ft3
Laju Alir
Debit umpan =
Densitas
C-188
12,7046 lb/s
=
61,4526 lb/ft3
= 0,206739 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas)
= 3,9 x (0,206739 ft3/s)0,45 x (61,4526 lb/ft3)0,13
= 3,277729 in
Dipilih untuk nozzle keluaran reaktor menggunakan pipa dengan diameter standar:
3 ½ in
4. Manhole
Setiap vessel yang dalam operasinya melibatkan cairan ataupun yang di
dalamnya terdapat alat lain seperti impeller, sebaiknya dilengkapi dengan manhole.
Manhole sangat dibutuhkan dalam vessel tertutup untuk pemeriksaan, pembersihan
kolom dan perbaikan. Direncanakan manhole dipasang pada kolom bagian atas
reaktor dengan ukuran standar 20 in berdasarkan rekomendasi API Standard 12 C
(Brownell and Young, Ap. F item 4), dengan spesifikasi :
Tebal shell = 0,3125 in
Tebal flange = 1 ½ in
Jumlah = satu
Ukuran potongan :
Weld A = 7/8 in
Weld B = 1,5 in
Panjang sisi = 42,5 in
Lebar reinforcement (W) = 49 in
Diameter manhole, ID = 20 in
Maksimum diameter lubang,
Dp = 27 in
Diameter plat penutup
cover plate = 28,75 in
Diameter bolt circle, DB = 26,25 in
C-189
= 0,003924 m = 0,5452 in