Sei sulla pagina 1di 190

LAMPIRAN C

PERHITUNGAN SPESIFIKASI PERALATAN

C.1 Tangki Penyimpanan Metil Formiat (TK-01)


Fungsi : Menyimpan Metil Formiat
Bahan Konstruksi : Carbon stell SA-283 Grade C
Bentuk :Silinder vertikal dengan alas datar dan tutup ellipsoidal
Jumlah : 1 unit
Kondisi operasi
Temperatur : 30 oC
Tekanan : 1 atm
Laju alir, W : 16144,79 kg/jam
Densitas, 𝜌 : 981,24 kg/m3
Lama persediaan, t : 7 hari
Safety Factor : 15%
Perhitungan:
a. Volume tangki, V
W x t x 24 jam/hari
V = (C.1)
ρ
kg
16144,79 x 7 hari x 24 jam/hari
jam
=
981,244 kg/m3

= 2764,169 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 2764,169 m3
= 3178,795 m3
b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve (C.2)
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana:
H = (3/2) Dt

C-1
C-2

H = (1/4) Dt (Tabel 6-51 Perry,1997)


maka,
3 Vt x 8
Dt = √ (C.3)
3xπ

3 3178,795 x 8
=√
3 x 3,14

= 13,924 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3 (C.4)
= 0,13 x (13,924)3
= 353,199 m3
Volume Silinder, Vs:
Vs = Vt – Ve (C.5)
= 3178,795 – 353,199
= 2410,97 m3
Tinggi Tangki Total, Ht:
Tinggi slinder, H = (3/2) × Dt (C.6)
= (3/2) x 13,924 m
= 20,886 m
Tinggi ellipsoidal, h = (1/4) Dt (C.7)
= (1/4) x 13,924 m
= 3,481 m
Maka, Ht = H + h (C.8)
= (20,886 + 3,481) m
= 17,405 m
Tebal Dinding Tangki, t:
P×D
t = +C (Tabel 14-4 Peter Timmerhaus, 1991) (C.9)
2 ×SE- 0,2 × P

Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 13,924 m
C-3

S = working stress yang diizinkan = 13700 psi = 932,226 atm


E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
1 atm x 13,924 m
t = + 0,0032 m
(2 x 932,226 atm x 0,85) - (0,2 x 1 atm)

t = 0,003 cm
OD = 2t + Dt (C.10)
= 2 (0,003) + 13,924 m
= 13,947 m

C.2 Tangki Penyimpanan Metanol (TK-02)


Fungsi : Menyimpan Produk Samping Metanol
Bahan Konstruksi : Carbon stell SA-283 Grade C
Bentuk :Silinder vertikal dengan alas datar dan tutup ellipsoidal
Jumlah : 1 unit
Kondisi operasi
Temperatur : 30 oC
Tekanan : 1 atm
Laju alir, W : 7819,87 kg/jam
Densitas, 𝜌 : 795,72 kg/m3
Lama persediaan, t : 7 hari
Safety Factor : 15%
Perhitungan:
a. Volume tangki, V
W x t x 24 jam/hari
V =
ρ
kg
7819,87 x 7 hari x 24 jam/hari
jam
=
795,72 kg/m3

= 1651,006 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 1651,006 m3
C-4

= 1898,656 m3
b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana: H = (3/2) Dt
h = (1/4) Dt (Tabel 6-51 Perry,1997)
maka,
3 Vt x 8
Dt = √ 3 x π

3 1898,656 x 8
=√ 3 x 3,14

= 11,726 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3
= 0,13 x (11,726)3
= 211,153 m3
Volume Silinder, Vs:
Vs = Vt – Ve
= 1898,656 – 211,153
= 1687,503 m3
Tinggi Tangki Total, Ht:
Tinggi slinder, H = (3/2) × Dt
= (3/2) x 11,726 m
= 17,589 m
Tinggi ellipsoidal, h = (1/4) Dt
= (1/4) x 11,726 m
= 2,931 m
Maka, Ht = H + h
= (17,589 + 2,931) m
= 20,521 m
C-5

Tebal Dinding Tangki, t:


P×D
t= +C (Tabel 14-4 Peter Timmerhaus,1991)
2 ×SE− 0,2 × P

Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 11,726 m
S = working stress yng diizinkan = 13700 psi = 932,226 atm
E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
1 atm x 11,726 m
t = + 0,0032 m
(2 x 932,226 atm x 0,85)- (0,2 x 1 atm)

t = 1,06 cm
OD = 2t + D
= 2 (1,06) + 11,726 m
= 11,747 m

C.3 Tangki Penyimpanan Asam Formiat (TK-03)


Fungsi : Menyimpan Produk Utama Asam Formiat
Bahan Konstruksi : Carbon stell SA-283 Grade C
Bentuk : Silinder vertikal dengan alas datar dan tutup ellipsoidal
Jumlah : 1 unit

Kondisi operasi
Temperatur : 30 oC
Tekanan : 1 atm
Laju alir, W : 11379,36 kg/jam
Densitas, 𝜌 : 1225,18 kg/m3
Lama persediaan, t : 7 hari
Safety Factor : 15%

Perhitungan:
C-6

a. Volume tangki, V
W x t x 24 jam/hari
V =
ρ
kg
11379,36 x 7 hari x 24 jam/hari
jam
=
1225,18 kg/m3

= 1560,36 m3
Safety Factor = 15%, maka
Vt = (1 + 0,15) x 1560,36 m3
= 1794,42 m3

b. Diameter Tangki, Dt
Volume total = volume silinder + volume ellipsoidal head
Vt = VS + Ve
= (π/4 × Dt 2 H) + (π/12 × Dt 3 )
Dimana: H = (3/2) Dt
h = (1/4) Dt (Tabel 6-51 Perry,1997)
maka,
3 Vt x 8
Dt = √
3xπ

3 1898,656 x 8
=√
3 x 3,14

= 11,507 m
Volume Ellipsoidal:
Ve = 𝜋/24 Dt3
= 0,13 x (11,507)3
= 199,56 m3
Volume Silinder, Vs:
Vs = Vt – Ve
= 1794,42 – 199,56
= 1594,86 m3
C-7

Tinggi Tangki Total, Ht:


Tinggi slinder, H = (3/2) × Dt
= (3/2) x 11,507 m
= 17,261 m
Tinggi ellipsoidal, h = (1/4) Dt
= (1/4) x 11,726 m
= 2,876 m
Maka, Ht = H + h
= (17,589 + 2,931) m
= 20,521 m
Tebal Dinding Tangki, t:
P×D
t= +C (Tabel 14-4 Peter Timmerhaus, 1991)
2 ×SE- 0,2 × P

Dimana,
P = tekanan desain = 1 atm
D = diameter tangki = 11,726 m
S = working stress yng diizinkan = 13700 psi = 932,226 atm
E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
1 atm x 11,726 m
t = + 0,0032 m
(2 x 932,226 atm x 0,85)- (0,2 x 1 atm)

t = 1,06 cm
OD = 2t + D
= 2 (1,06) + 11,726 m
= 11,528 m

C.4 Pompa (P-01)


Fungsi : Untuk mengalirkan bahan baku metil formiat dari tangki
penyimpanan metil formiat (TK-01)
Tipe : Pompa Sentrifugal
C-8

Jumlah : 1 unit
Data :
Temperatur , T = 30°C = 86°F
Laju Alir, W = 16199,05 kg/jam = 595,314 lb/menit
Densitas, ρ = 981,244 kg/m3 = 61,258 (lb)/ft3
Viscositas, μ = 0,312 cP = 0,00021 (lb)/ft
Kapasitas Pompa, Qf:
Qf = 1 + (0,1×w/ρ) (C.11)
= 1 + (0,1× (595,314 lb/menit)/(61,258 lb/ft3 ))
= 0,161 ft3/detik
Qf = 9,718 ft3/menit

Penentuan Ukuran Pipa


1. Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus,1991) (C.12)
= 3,9 × (0.0161 ft3/detik)0,45× (61,258 lb/ft3 )0,13
= 18,527 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
1
IPS = 22 in

ID = 2,469 in = 0,206 ft
OD = 2,875 in = 0,240 ft
Luas Penampang = 0,033 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a (C.13)
= (0,161 ft3/detik)/( 0,033 ft2)
= 4,875 ft/detik
C-9

Reynold Number, NRe:


NRe = ( Dvρ)/µ (C.14)
NRe = (0,206 ft × 4,875 ft/detik × 61,258 (lb)/ft3)/(0,00021 (lb)/(ft.jam)
= 292896,1 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,206 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/(0,206 ft) = 0,0007
Dari data nilai NRe = 292896,1 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 4,2

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,206 ft = 2,400 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,206 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,206 ft = 0,154 ft
C-10

Panjang ekivalen,
Le = 2,400 ft + 5,144 ft + 0,154 f
= 7,698 ft
4. Menghitung Kehilangan Fraksi
a. Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (Geankoplis,1993 tabel 2.10-1)
V2
Hf = Kf ( ) (C.15)
2 x α xgc

ft 2
(4,875 )
detik
=0, 75( )
2 x 1 x 32,174

= 997,487 ft.lbf/lbm
b. Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( ) (C.16)
2 x α xgc

ft 2
(4,875 )
detik
= 0,17( )
2 x 1 x 32,174

= 0,062 ft.lbf/lbm
c. Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( ) (C.17)
2 x α xgc

ft 2
(4,875 detik)
= 6( )
2 x 1 x 32,174

= 2,216 ft.lbf/lbm
Total Hf = 0,277 ft.lbf/lbm + 0,062 ft.lbf/lbm + 2,216 ft.lbf/lbm
= 2,556 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1- )x ( ) (C.18)
A2 2 x α x gc
C-11

ft 2
(4,875 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,203 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
) (C.19)

ft 2
(4,875 )
detik
= (1-0)x ( )
2 x 1 x 32,174

= 0,369 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx ( )x ( ) (C.20)
ID 2 x α x gc

ft 2
30 (4,875 )
detik
= 4 x 30 x (
7,698
) x (2 x 1 x 32,174)

= 137,977 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff (C.21)
= 0,203 ft.lbf/lbm + 0,369 ft.lbf/lbm + 137,977 ft.lbf/lbm
= 137,977 ft.lbf/lbm

5. Menentukan Daya Pompa


Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws (C.22)
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 137,977 + Ws = 170,151


Ws = -153,551
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp = (C.23)

-153,551
=
-0,80
C-12

= 191,939 ft.lbf/lbm

Daya Pompa:
P = m x Wp (C.24)
= 9,921 lbm/s x 212,687 ft.lbf/lbm
= 1904,405 ft.lbf/s = 3,462 hp

C.5 Pompa (P-02)


Fungsi : Untuk mengalirkan bahan baku air
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 80°C = 176°F
Laju Alir, W = 4546,83 kg/jam = 167,096 lb/menit
Densitas, ρ = 997,986 kg/m3 = 62,302 (lb)/ft3
Viscositas, μ = 0,8007 cP = 0,000538 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (167,096 lb/menit)/(62,302 lb/ft3 ))
= 0,044 ft3/detik
Qf = 2,682 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter,1991 Ed.3)
= 3,9 × (0,044 ft3/detik)0,45× (62,302 lb/ft3 )0,13
= 1,648 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
C-13

Suction pipe
SN = 40
1
IPS = 22 in

ID = 2,469 in = 0,206 ft
OD = 2,875 in = 0,240 ft
Luas Penampang = 0,033 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (0,044 ft3/detik)/( 0,033 ft2)
= 1,345 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,206 ft ×1,345 ft/detik × 62,302 (lb)/ft3)/(0,000538 (lb)/ft
= 32057,961 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,206 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/(0,206 ft) = 0,0007
Dari data nilai NRe = 32057,961 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 4,2
C-14

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,206 ft = 2,400 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,206 ft = 5,144 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,206 ft = 0,154 ft
Panjang ekivalen,
Le = 2,400 ft + 5,144 ft + 0,154 f
= 7,698 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (Geankoplis tabel 2.10-1, 93)
V2
Hf = Kf (2 x α xgc)

ft 2
(1,345 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,021 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(1,345 )
detik
= 0,17( )
2 x 1 x 32,174

= 0,004 ft.lbf/lbm
C-15

Terdapat 1 buah globe valve, Kf = 6


V2
Hf = Kf( )
2 x α xgc

ft 2
(1,345 )
detik
=6 ( )
2 x 1 x 32,174

= 0,168 ft.lbf/lbm
Total Hf = 0,021 ft.lbf/lbm + 0,004 ft.lbf/lbm + 0,0168 ft.lbf/lbm
= 0,194 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1- )x ( )
A2 2 x α x gc

ft 2
(1,345 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,015 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(1,345 )
detik
= (1-0)x ( )
2 x 1 x 32,174

= 0,028 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx ( )x ( )
ID 2 x α x gc

ft 2
30 (1,345 )
detik
= 4 x 30 x ( ) x (2 x 1 x 32,174)
7,698

= 38,078 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,200 ft.lbf/lbm + 0,362 ft.lbf/lbm + 38,078 ft.lbf/lbm
C-16

= 38,122 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 38,122 + Ws = 53,123


Ws = -53,123
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-53,123
=
-0,80

= 66,404 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 2,789 x 66,404 ft.lbf/lbm
= 184,931 ft.lbf/s = 0,33 hp

C.6 Pompa (P-03)


Fungsi : Untuk mengalirkan campuran keluaran dari mixer
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 30°C = 86°F
Laju Alir, W = 16199,05 kg/jam = 35.718,9 lb/menit
Densitas, ρ = 981,244 kg/m3 = 61,2571 (lb)/ft3
Viscositas, μ = 0,3122 cP = 0,00021 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (35.718,9 lb/menit)/( 61,2571 (lb/ft3))
= 0,161972 ft3/detik
C-17

Qf = 9,7183 ft3/menit
Penentuan Ukuran Pipa
Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,161972 ft3/detik)0,45× (61,2571 (lb/ft3)0,13
= 2,935233 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 3 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (9,7183 ft3/menit)/( 0,647 ft2)
= 0,2503 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,2556 ft ×0,2503 ft/detik × 61,2571 lb/ft3)/( 0,00021 (lb)/ft
= 18.687,16 (Turbulent, NRe > 2100)
Menghitung Fanning Friction Factor, f:
Faktor koreksi:
Diameter pipa :
ID = 0,2556 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
C-18

(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)


ε/D = (0,00015ft )/( 0,2556 ft) = 0,0006
Dari data nilai NRe = 18.687,16 (> 2100, Turbulent flow) dan nilai ε/D = 0,0006
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00454

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 20 m = 65,6168 ft
Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,2556 ft = 2,9827 ft
1. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,2556 ft = 6,3916 ft
2. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,2556 ft = 0,19175 ft
Panjang ekivalen,
Le = 2,9827 ft + 6,3916 ft + 0,19175 ft
= 9,566194 ft
3. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1 Geankoplis,1993)
V2
Hf =Kf( )
2 x α xgc

ft 2
(0,2503 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,0073 ft.lbf/lbm
C-19

Terdapat 1 buah gate valve, Kf = 0,17


V2
Hf = Kf( )
2 x α xgc

ft 2
(0,2503 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,00166 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf =Kf ( )
2 x α xgc

ft 2
(0,2503 )
detik
=6 ( )
2 x 1 x 32,174

= 0,00536 ft.lbf/lbm
Total Hf = 0,0073 ft.lbf/lbm + 0,00166 ft.lbf/lbm + 0,00536 ft.lbf/lbm
= 0,0674 ft.lbf/lbm

Contraction loss pada tank exit:


A V2
Hc = 0,55 x (1- A1 ) x ( 2 x α x gc)
2

ft 2
(0,2503 detik)
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )

= 0,000536 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,2503 )
detik
= (1-0)x ( )
2 x 1 x 32,174

= 0,000974 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff = 4 x f x ( ID ) x ( 2 x α x gc)
C-20

ft 2
0,00454 (0,2503 detik)
=4 x 0,00545 x (0,25566) x ( 2 x 1 x 32,174 )

= 0,00346 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000536 ft.lbf/lbm + 0,000974 ft.lbf/lbm + 0,00346 ft.lbf/lbm
= 0,003461 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,003461 + Ws = 53,123


Ws = -15,0062
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp = -μ
-15,0062
= -0,80

= 18,7577 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 184,931 ft.lbf/s
= 0,33 hp

C.7 Pompa (P-04)


Fungsi : Untuk mengalirkan campuran keluaran dari HE-01
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 80°C = 176 °F
Laju Alir, W = 16199,05 kg/jam = 9,9219 lb/s
C-21

Densitas, ρ = 981,244 kg/m3 = 61,2571 (lb)/ft3


Viscositas, μ = 0,3122 cP = 0,00021 (lb)/ft
Kapasitas Pompa, Qf:
Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (35.718,9 lb/menit)/( 61,2571 (lb/ft3))
= 0,161972 ft3/detik
Qf = 9,7183 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus,1991 Ed.3)
= 3,9 × (0,161972 ft3/detik)0,45× (61,2571 (lb/ft3)0,13
= 2,935233 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 3 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (9,7183 ft3/menit)/( 0,647 ft2)
= 0,2503 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,2556 ft ×0,2503 ft/detik × 61,2571 lb/ft3)/( 0,00021 (lb)/ft
C-22

= 18.687,16 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,2556 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,2556 ft) = 0,0006
Dari data nilai NRe = 18.687,16 (> 2100, Turbulent flow) dan nilai ε/D = 0,0006
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00454

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 20 m = 65,6168 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,2556 ft = 2,9827 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,2556 ft = 6,3916 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,2556 ft = 0,19175 ft
Panjang ekivalen,
Le = 2,9827 ft + 6,3916 ft + 0,19175 ft
= 9,566194 ft
C-23

4. Menghitung Kehilangan Fraksi


Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1 Geankoplis, 1993)
V2
Hf =Kf ( )
2 x α xgc

ft 2
(0,2503 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,0073 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf( )
2 x α xgc

ft 2
(0,2503 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,00166 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,2503 )
detik
=6 ( )
2 x 1 x 32,174

= 0,00536 ft.lbf/lbm
Total Hf = 0,0073 ft.lbf/lbm + 0,00166 ft.lbf/lbm + 0,00536 ft.lbf/lbm
= 0,0674 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1- )x ( )
A2 2 x α x gc

ft 2
(0,2503 )
detik
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )

= 0,000536 ft.lbf/lbm
C-24

Expantion loss entrance tank:


A1 V2
Hex = (1- )x ( )
A2 2 x α x gc

ft 2
(0,2503 )
detik
= (1-0)x ( 2 x 1 x 32,174 )

= 0,000974 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,2503 )
detik
=4 x 0,00545 x (
0,25566
) x ( 2 x 1 x 32,174 )

= 0,00346 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000536 ft.lbf/lbm + 0,000974 ft.lbf/lbm + 0,00346 ft.lbf/lbm
= 0,003461 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,003461 + Ws = 53,123


Ws = -15,0062
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0062
=
-0,80

= 18,7577 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 184,931 ft.lbf/s = 0,33 hp
C-25

C.8 Pompa (P-05)


Fungsi : Untuk mengalirkan campuran keluaran dari Reaktor
Tipe : Pompa Sentrifugal
Jumlah : 1 unit

Data :
Temperatur , T = 80°C = 176 °F
Laju Alir, W = 20.745,88 kg/jam = 12,7068 lb/s
Densitas, ρ = 984,3764 kg/m3 = 61,45262 (lb)/ft3
Viscositas, μ = 0,4416 cP = 0,00029 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (12,7068 lb/s)/( 61,45262 lb/ft3)
=0,16124 ft3/detik
Qf = 9,745 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,16124 ft3/detik)0,45× (61,45262 (lb)/ft3)0,13
= 3,2775 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 31/2 in
ID = 3,068 in = 0,2556 ft
OD = 3,5 in = 0,29166 ft
C-26

Luas Penampang = 0,804 ft2


Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a
= (0,16124 ft3/detik)/( 0,804 ft2)
= 0,2067 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,2556 ft × 0,2067 ft/detik × 61,4526 lb/ft3)/( 0,00021 (lb)/ft
= 13.616,48 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,2556 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,2556 ft) = 0,0006
Dari data nilai NRe = 13.616,48 (> 2100, Turbulent flow) dan nilai ε/D = 0,0006
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00454

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,2556 ft = 2,9827 ft
C-27

2. Digunakan 1 buah globe valve


Le/D = 300 in
Le = 1 x 25 x 0,2556 ft = 6,3916 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,2556 ft = 0,19175 ft
Panjang ekivalen,
Le = 2,9827 ft + 6,3916 ft + 0,19175 ft
= 9,566194 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1 Geankoplis,1993)
2
V
Hf = Kf (2 x α xgc)

ft 2
(0,2067 )
detik
= 0,75 ( 2 x 1 x 32,174 )

= 0,00771 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf (2 x α xgc)

ft 2
(0,2067 )
detik
= 0,17 ( )
2 x 1 x 32,174

= 0,00175 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,2067 )
detik
= 6 ( 2 x 1 x 32,174 )

= 0,00616 ft.lbf/lbm
Total Hf = 0,00771 ft.lbf/lbm + 0,00175 ft.lbf/lbm + 0,00616 ft.lbf/lbm
= 0,07113 ft.lbf/lbm
C-28

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1- )x ( )
A2 2 x α x gc

ft 2
(0,2067 )
detik
= 0,55 x (1-0)x ( 2 x 1 x 32,174 )

= 0,000565 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1- )x ( )
A2 2 x α x gc

ft 2
(0,2067 )
detik
= (1-0)x ( 2 x 1 x 32,174 )

= 0,0001208 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4xfx (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,2067 )
detik
= 4 x 0,00545 x (
0,25566
) x ( 2 x 1 x 32,174 )

= 0,006964 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000565 ft.lbf/lbm + 0,0001208 ft.lbf/lbm + 0,006964 ft.lbf/lbm
= 0,008557 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,008557 + Ws = 53,123


Ws = -15,0098
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

C-29

-15,0098
=
-0,80

= 18,7622 ft.lbf/lbm

5. Daya Pompa:
P = m x Wp
= 9,9219 lbm/s x 18,7577 ft.lbf/lbm
= 238,4084 ft.lbf/s
= 0,43347 hp

C.9 Pompa (P-06)


Fungsi : Untuk mengalirkan campuran keluaran BTM D-01
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 142,9 °C = 289,22 °F
Laju Alir, W = 11.379,36 kg/jam = 6,9698 lb/s
Densitas, ρ = 1.205,588 kg/m3 = 75,2624 (lb)/ft3
Viscositas, μ = 0,3015 cP = 0,0002 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (6,9698 lb/s)/( 5,2624 (lb)/ft3)
=0,0926 ft3/detik
Qf = 5,556 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,0926 ft3/detik)0,45× (75,2624 (lb)/ft3)0,13
= 2,344 in
C-30

Ukuran-ukuran Pipa
Data standar dimensi pipa. (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 32,469 in = 0,205 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a
= (0,0926 ft3/detik)/( 0,647 ft2)
= 0,14133 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,205 ft × 0,14133 ft/detik × 75,2624 (lb)/ft3)/( 0,0002 (lb)/ft)
= 10.937,75 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,205 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,205 ft) = 0,0007
Dari data nilai NRe = 10.937,75 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548
C-31

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 20 m = 65,6168 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1991)
Le/D = 35 in
Le = 4 x 2,91667 x 0,205 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,205 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,205 ft = 0,154 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,154 ft
= 7,6984 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (Geankoplis tabel 2.10-1,1993)
V2
Hf = Kf (2 x α xgc)

ft 2
(0,14133 detik)
=0,75 ( 2 x 1 x 32,174 )

= 0,00239 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,14133 detik)
= 0,17 ( 2 x 1 x 32,174 )

= 0,0000541 ft.lbf/lbm
C-32

Terdapat 1 buah globe valve, Kf = 6


V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,14133 )
detik
=6( )
2 x 1 x 32,174

= 0,00191 ft.lbf/lbm
Total Hf = 0,00239 ft.lbf/lbm + 0,0000541 ft.lbf/lbm + 0,00191 ft.lbf/lbm
= 0,002203 ft.lbf/lbm

Contraction loss pada tank exit:


A V2
Hc = 0,55 x (1- A1 ) x ( 2 x α x gc)
2

ft 2
(0,14133 )
detik
=0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,000175 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,14133 )
detik
= (1-0) x ( )
2 x 1 x 32,174

= 0,0003183 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,14133 )
detik
=4 x 0,00548 x (0,25566) x ( )
2 x 1 x 32,174

= 0,002915 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000175 ft.lbf/lbm + 0,0003183 ft.lbf/lbm + 0,002915 ft.lbf/lbm
= 0,003408 ft.lbf/lbm
C-33

Menentukan Daya Pompa


Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,003408 + Ws = 53,123


Ws = -15,0046
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0046
=
-0,80

= 18,7557 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
6,9698 lbm/s x 18,7557 ft.lbf/lbm
= 130,725 ft.lbf/s
= 0,2376 hp

C.10 Pompa (P-07)


Fungsi : Untuk mengalirkan fluida keluaran HE-04
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 30 °C = 86 °F
Laju Alir, W = 11.379,36 kg/jam = 6,9698 lb/s
Densitas, ρ = 1.205,588 kg/m3 = 75,2624 (lb)/ft3
Viscositas, μ = 1,31365 cP = 0,0002 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (6,9698 lb/s)/( 5,2624 (lb)/ft3)
=0,0926 ft3/detik = 5,556 ft3/menit
C-34

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,0926 ft3/detik)0,45× (75,2624 (lb)/ft3)0,13
= 2,344 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (0,0926 ft3/detik)/( 0,647 ft2)
= 0,14133 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,20575 ft × 0,14133 ft/detik × 75,2624 (lb)/ft3)/( 0,00088 (lb)/ft)
= 2.510,897 (Turbulent, NRe > 2100)
Menghitung Fanning Friction Factor, f:
Faktor koreksi:
Diameter pipa :
ID = 0,20575 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
C-35

ε/D = (0,00015ft )/( 0,20575 ft) = 0,0007


Dari data nilai NRe = 2.510,897 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 20 m = 65,6168 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,205 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,205 ft = 0,154 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,154 ft
= 7,6984 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, Geankoplis 1993)
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,14133 )
detik
= 0,75 ( )
2 x 1 x 32,174

= 0,00239 ft.lbf/lbm
C-36

Terdapat 1 buah gate valve, Kf = 0,17


V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,14133 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,0000541 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,14133 )
detik
=6 ( )
2 x 1 x 32,174

= 0,00191 ft.lbf/lbm
Total Hf = 0,00239 ft.lbf/lbm + 0,0000541 ft.lbf/lbm + 0,00191 ft.lbf/lbm
= 0,002203 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc =0,55 x (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,14133 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,000175 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,14133 )
detik
=(1-0) x ( )
2 x 1 x 32,174

= 0,0003183 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
C-37

ft 2
0,00454 (0,14133 )
detik
=4 x 0,00548 x (
0,25566
)x ( 2 x 1 x 32,174
)

= 0,002915 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000175 ft.lbf/lbm + 0,0003183 ft.lbf/lbm + 0,002915 ft.lbf/lbm
= 0,003408 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,003408 + Ws = 53,123


Ws = -15,0046
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0046
=
-0,80

= 18,7557 ft.lbf/lbm

5. Daya Pompa:
P = m x Wp
6,9698 lbm/s x 18,7557 ft.lbf/lbm
= 130,725 ft.lbf/s
= 0,2376 hp

C.11 Pompa (P-08)


Fungsi : Untuk mengalirkan campuran keluaran UP D-01
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
C-38

Data :
Temperatur , T = 82,81 °C = 181,058°F
Laju Alir, W = 9.366,52 kg/jam = 5,7369 lb/s
Densitas, ρ = 822,6675 kg/m3 = 51,3574 (lb)/ft3
Viscositas, μ = 0,2579 cP = 0,000173 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (5,7369 lb/s)/ 0,000173 (lb)/ft
= 0,111707 ft3/detik
Qf = 6,702 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,111707 ft3/detik)0,45× (0,000173 (lb)/(ft.jam))0,13
= 2,427 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
Penentuan Suction velocity, v :
v = Qf/a
= (0,111707 ft3/detik)/( 0,647 ft2)
= 0,17264 ft/detik
C-39

Reynold Number, NRe:


NRe = ( Dvρ)/µ
NRe = (0,20575 ft × 0,17264 ft/detik × 75,2624 (lb)/ft3)/ 0,000173 (lb)/ft
= 2.510,897 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,20575 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,20575 ft) = 0,0007
Dari data nilai NRe = 2.510,897 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548
Perhitungan Panjang Pendek Pipa Ekivalen
Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)

Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,205 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,205 ft = 0,154 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,154 ft
C-40

= 7,6984 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, Geankoplis 1993)
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,00347 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,0000788 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
=6
2 x 1 x 32,174

= 0,00278 ft.lbf/lbm
Total Hf = 0,00347 ft.lbf/lbm + 0,0000788 ft.lbf/lbm + 0,00278 ft.lbf/lbm
= 0,003206 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1-
A2
)x ( 2 x α x gc
)
ft 2
( 0,17264 )
detik
= 0,55 x (1-0) x ( )
2 x 1 x 32,174

= 0,000255 ft.lbf/lbm
C-41

Expantion loss entrance tank:


A1 V2
Hex = (1-
A2
)x ( 2 x α x gc
)
ft 2
(0,17264 )
detik
=(1-0) x ( )
2 x 1 x 32,174

= 0,000463 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff = 4 x f x ( ID ) x ( )
2 x α x gc

ft 2
0,00454 (0,17264 )
detik
=4 x 0,00548 x (
0,2575
) x ( 2 x 1 x 32,174 )

= 0,006375 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000255 ft.lbf/lbm + 0,000463 ft.lbf/lbm + 0,006375 ft.lbf/lbm
= 0,007093 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,007093 + Ws = 53,123


Ws = -15,0083
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0083
=
-0,80

= 18,76 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 5,7369 lb/s x 18,76 ft.lbf/lbm
C-42

= 107,628 ft.lbf/s
= 0,195 hp

C.12 Pompa (P-09)


Fungsi :Untuk mengalirkan campuran keluaran HE-02
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 40 °C = 104 °F
Laju Alir, W = 9.366,52 kg/jam = 5,7369 lb/s
Densitas, ρ = 822,6675 kg/m3 = 51,3574 (lb)/ft3
Viscositas, μ = 0,421 cP = 0,000283 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (5,7369 lb/s)/ 51,3574 (lb)/ft3
= 0,111707 ft3/detik
Qf = 6,702 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,111707 ft3/detik)0,45× (0,000173 (lb)/(ft.jam))0,13
= 2,427 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 21/2 in
ID = 2,469 in = 0,20575 ft
C-43

OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (0,111707 ft3/detik)/( 0,647 ft2)
= 0,17264 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,20575 ft × 0,17264 ft/detik × 75,2624 (lb)/ft3)/ 0,000173 (lb)/(ft.jam)
= 2.510,897 (Turbulent, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,20575 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,20575 ft) = 0,0007
Dari data nilai NRe = 2.510,897 (> 2100, Turbulent flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548
Perhitungan Panjang Pendek Pipa Ekivalen
Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
C-44

2. Digunakan 1 buah globe valve


Le/D = 300 in
Le = 1 x 25 x 0,205 ft = 5,143 ft
Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,205 ft = 0,154 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,154 ft
= 7,6984 ft
Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1 Geankoplis, 1993)
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
= 0,75( )
2 x 1 x 32,174

= 0,00347 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,0000788 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,17264 )
detik
=6 ( )
2 x 1 x 32,174

= 0,00278 ft.lbf/lbm
Total Hf = 0,00347 ft.lbf/lbm + 0,0000788 ft.lbf/lbm + 0,00278 ft.lbf/lbm
C-45

= 0,003206 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc =0,55 x (1-
A2
)x ( 2 x α x gc
)
ft 2
( 0,17264 )
detik
=0,55 x (1-0) x ( )
2 x 1 x 32,174

= 0,000255 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1- )x ( )
A2 2 x α x gc

ft 2
(0,17264 )
detik
=(1-0)x ( )
2 x 1 x 32,174

= 0,000463 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,17264 )
detik
=4 x 0,00548 x (
0,2575
) x ( 2 x 1 x 32,174 )

= 0,006375 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,000255 ft.lbf/lbm + 0,000463 ft.lbf/lbm + 0,006375 ft.lbf/lbm
= 0,007093 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,007093 + Ws = 53,123


Ws = -15,0083
C-46

Untuk efisiensi pompa, η = 80 %, maka:


WS
Wp = -μ

-15,0083
=
-0,80

= 18,76 ft.lbf/lbm
Daya Pompa:
P = m x Wp
= 5,7369 lb/s x 18,76 ft.lbf/lbm
= 107,628 ft.lbf/s
= 0,1956 hp

C.12 Pompa (P-10)


Fungsi : Untuk mengalirkan campuran keluaran UP D-02
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 31,72 °C = 189,096 °F
Laju Alir, W = 1.546,65 kg/jam = 0,947 lb/s
Densitas, ρ = 975,2436 kg/m3 = 60,8825 (lb)/ft3
Viscositas, μ = 0,312 cP = 0,00021 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (5,7369 lb/s)/ 51,3574 (lb)/ft3
=,01556 ft3/detik
Qf = 6,702 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3))
C-47

= 3,9 × (0,01556 ft3/detik)0,45× (0,00021 (lb)/(ft.jam))0,13


= 1,022 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 1 1/4 in
ID = 1,38 in = 0,115 ft
OD = 1,66 in = 0,138 ft
Luas Penampang = 0,362 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (0,01556 ft3/detik)/( 0,362 ft2)
= 0,0429 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,115 ft × 0,0429 ft/detik × 60,8825 (lb)/ft3 / 0,00021 (lb)/ft
= 1.434,914 (Laminar, NRe < 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,115 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,115 ft) = 0,0013
C-48

Dari data nilai NRe = 1.434,914 (< 2100, laminar flow) dan nilai ε/D = 0,0013
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,019

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,115 ft = 1,34 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,115 ft = 2,874 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,115 ft = 0,0086 ft
Panjang ekivalen,
Le = 1,34 ft + 2,874 ft + 0,0086 ft
= 4,302 ft
4. Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, Geankoplis 1993)
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,0429 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,0000215 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc
C-49

ft 2
(0,0429 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,0000488 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,0429 )
detik
=6 ( )
2 x 1 x 32,174

= 0,000172 ft.lbf/lbm
Total Hf = 0,000021 ft.lbf/lbm + 0,0000488 ft.lbf/lbm + 0,000172 ft.lbf/lbm
= 0,000199 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc =0,55 x (1-
A2
)x ( 2 x α x gc
)
ft 2
( 0,0429 )
detik
=0,55 x (1-0) x ( )
2 x 1 x 32,174

= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1-
A2
)x ( 2 x α x gc
)
ft 2
(0,0429 )
detik
=(1-0)x ( )
2 x 1 x 32,174

= 0,0000287 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,0429 )
detik
=4 x 0,019 x (
0,155
) x ( 2 x 1 x 32,174 )

= 0,01134 ft.lbf/lbm
C-50

Sehingga total friction loss yang terjadi pada sistem perpipaan:


∑f = Hc + Hex + Ff
= 0,0000158 ft.lbf/lbm + 0,0000287 ft.lbf/lbm + 0,01134 ft.lbf/lbm
= 0,011388 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,011388 + Ws = 53,123


Ws = -15,0126
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0126
=
-0,80

= 18,765 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 0,9473 lb/s x 18,765 ft.lbf/lbm
= 17,77 ft.lbf/s
= 0,0323 hp

C.12 Pompa (P-11)


Fungsi :Untuk mengalirkan campuran keluaran BTM D-02
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 62,91°C = 145,238 °F
Laju Alir, W = 7.819,87 kg/jam = 4,7896 lb/s
Densitas, ρ = 798,967 kg/m3 = 49,877 (lb)/ft3
Viscositas, μ = 0,3344 cP = 0,000225 (lb)/ft
C-51

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (4,7896 lb/s)/ 49,877 (lb)/ft3
= 0,096 ft3/detik
Qf = 5,7616ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,096 ft3/detik)0,45× (0,000225 (lb)/(ft.jam))0,13
= 2,258 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 2 1/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel

Penentuan Suction velocity, v :


v = Qf/a
= (0,096 ft3/detik)/( 0,647 ft2)
= 0,1484 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,20575 ft × 0,1484 ft/detik × 49,877 (lb)/ft3 / 0,000225 (lb)/ft
= 6.776,609 (Turbulen, NRe > 2100)
C-52

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,20575 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,20575 ft) = 0,0007
Dari data nilai NRe = 6.777,709 (> 2100, turbulen flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548

Perhitungan Panjang Pendek Pipa Ekivalen


Direncanakan:
Panjang pipa lurus = 30 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,20575 ft = 5,143 ft
3. Digunakan 1 buah gate valve
Le/D = 9 in
Le = 1 x 0,75 x 0,20575 ft = 0,1543 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,1543 ft
= 7,698 ft
Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, Geankoplis 1993)
C-53

V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,1484 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,000257 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,1484 )
detik
=0,17 ( )
2 x 1 x 32,174

= 0,0000582 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc
ft 2
(0,1484 )
detik
= 6( )
2 x 1 x 32,174

= 0,002054 ft.lbf/lbm
Total Hf = 0,000257 ft.lbf/lbm + 0,0000582 ft.lbf/lbm + 0,002054 ft.lbf/lbm
= 0,002369 ft.lbf/lbm

Contraction loss pada tank exit:


A1 V2
Hc = 0,55 x (1- )x ( )
A2 2 x α x gc

ft 2
( 0,1484 )
detik
= 0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex = (1- )x ( )
A2 2 x α x gc

ft 2
(0,1484 )
detik
= (1-0)x ( 2 x 1 x 32,174 )
C-54

= 0,000342 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,1484 )
detik
=4 x 0,00548 x (
0,20575
) x ( 2 x 1 x 32,174 )

= 0,00548 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,0000158 ft.lbf/lbm + 0,000342 ft.lbf/lbm + 0,00548 ft.lbf/lbm
= 0,00601 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,00601 + Ws = 53,123


Ws = -15,0721
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

-15,0721
=
-0,80

= 18,759 ft.lbf/lbm

5. Daya Pompa:
P = m x Wp
= 4,789 lb/s x 18,759 ft.lbf/lbm
= 89,849 ft.lbf/s
= 0,163 hp
C-55

C.13 Pompa (P-12)


Fungsi : Untuk mengalirkan campuran keluaran HE-03
Tipe : Pompa Sentrifugal
Jumlah : 1 unit
Data :
Temperatur , T = 30°C = 86 °F
Laju Alir, W = 7.819,87 kg/jam = 4,7896 lb/s
Densitas, ρ = 798,1859 kg/m3 = 49,829 (lb)/ft3
Viscositas, μ = 0, 4432 cP = 0,000298 (lb)/ft

Kapasitas Pompa, Qf:


Qf = 1 + (0,1×w/ρ)
= 1 + (0,1× (4,7896 lb/s)/ 49,829(lb)/ft3
= 0,096 ft3/detik
Qf = 5,7673 ft3/menit

Penentuan Ukuran Pipa


Diameter optimum, Dopt:
Dopt = 3,9 x Qf0,45 x ρ0,13 (Pers.14-15, Peter Timmerhaus, 1991 Ed.3)
= 3,9 × (0,096 ft3/detik)0,45× (0,000298 (lb)/(ft.jam))0,13
= 2,259 in

Ukuran-ukuran Pipa
Data standar dimensi pipa (Tabel. A.5-1 Geankoplis,1993)
Suction pipe
SN = 40
IPS = 2 1/2 in
ID = 2,469 in = 0,20575 ft
OD = 2,88 in = 0,24 ft
Luas Penampang = 0,647 ft2
Bahan Konstruksi = pipa commercial steel
C-56

Penentuan Suction velocity, v :


v = Qf/a
= (0,096 ft3/detik)/( 0,647 ft2)
= 0,1484 ft/detik
Reynold Number, NRe:
NRe = ( Dvρ)/µ
NRe = (0,20575 ft × 0,1484 ft/detik × 49,829 (lb)/ft3 / 0,000298 (lb)/ ft
= 5.114,296 (Turbulen, NRe > 2100)

Menghitung Fanning Friction Factor, f:


Faktor koreksi:
Diameter pipa :
ID = 0,20575 ft
Equivalent roughness (ε)
ε = 0,000046 m = 0,00015ft
(Fiq.2.10-3 commercial steel pipe Geankoplis, 1993)
ε/D = (0,00015ft )/( 0,20575 ft) = 0,0007
Dari data nilai NRe = 6.777,709 (> 2100, turbulen flow) dan nilai ε/D = 0,0007
maka dilakukan penarikan garis kurva pada Fiq.2.10-3 Grafik friction factor for
fluids inside pipes (Geankoplis, 1993) dan diperoleh nilai fanning friction factor (f)
= 0,00548
Perhitungan Panjang Pendek Pipa Ekivalen
Direncanakan:
Panjang pipa lurus = 40 m = 98,4252 ft
1. Digunakan 4 Buah Elbow 90° (tabel 2,10-1, hal 93 : Geankoplis,1993)
Le/D = 35 in
Le = 4 x 2,91667 x 0,20575 ft = 2,4 ft
2. Digunakan 1 buah globe valve
Le/D = 300 in
Le = 1 x 25 x 0,20575 ft = 5,143 ft
C-57

3. Digunakan 1 buah gate valve


Le/D = 9 in
Le = 1 x 0,75 x 0,20575 ft = 0,1543 ft
Panjang ekivalen,
Le = 2,4 ft + 5,143 ft + 0,1543 ft
= 7,698 ft
Menghitung Kehilangan Fraksi
Kehilangan fraksi pada elbow 90° dan valve :
Terdapat 4 buah elbow 90°, Kf = 0,75 (tabel 2.10-1, GeankopliS,1993)
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,1484 )
detik
=0,75 ( )
2 x 1 x 32,174

= 0,000257 ft.lbf/lbm
Terdapat 1 buah gate valve, Kf = 0,17
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,1484 )
detik
=0,17(
2 x 1 x 32,174
)

= 0,0000582 ft.lbf/lbm
Terdapat 1 buah globe valve, Kf = 6
V2
Hf = Kf ( )
2 x α xgc

ft 2
(0,1484 )
detik
=6 ( )
2 x 1 x 32,174

= 0,002054 ft.lbf/lbm
Total Hf = 0,000257 ft.lbf/lbm + 0,0000582 ft.lbf/lbm + 0,002054 ft.lbf/lbm
= 0,002369 ft.lbf/lbm
C-58

Contraction loss pada tank exit:


A1 V2
Hc =0,55 x (1-
A2
)x ( 2 x α x gc
)
ft 2
( 0,1484 )
detik
=0,55 x (1-0)x ( )
2 x 1 x 32,174

= 0,0000158 ft.lbf/lbm
Expantion loss entrance tank:
A1 V2
Hex =(1- )x ( )
A2 2 x α x gc

ft 2
(0,1484 )
detik
=(1-0)x ( )
2 x 1 x 32,174

= 0,000342 ft.lbf/lbm
Kehilangan pada pipa:
∆L V2
Ff =4 x f x (
ID
)x ( 2 x α x gc
)
ft 2
0,00454 (0,1484 )
detik
=4 x 0,00548 x (
0,20575
) x ( 2 x 1 x 32,174 )

= 0,00548 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑f = Hc + Hex + Ff
= 0,0000158 ft.lbf/lbm + 0,000342 ft.lbf/lbm + 0,00548 ft.lbf/lbm
= 0,00601 ft.lbf/lbm
Menentukan Daya Pompa
Dari persamaan Bernouli:
1 ∆V2 g ∆P
= + ∆Z + + ∑ F+ Ws
2α gc gc ρ

= 0 + 32,174 (0,466215) + 0,0012 + 0,00601 + Ws = 53,123


Ws = -15,0721
Untuk efisiensi pompa, η = 80 %, maka:
WS
Wp =

C-59

-15,0721
=
-0,80

= 18,759 ft.lbf/lbm
5. Daya Pompa:
P = m x Wp
= 4,789 lb/s x 18,759 ft.lbf/lbm
= 89,849 ft.lbf/s
= 0,163 hp

C.14 Mixer (M-01)


Fungsi : Untuk mencampur M-Formiat dari tangki bahan baku dengan
hasil recycle
Jenis : vessel vertikal
Tekanan = 1 atm = 14,7 psia
ρ campuran = 980,62 kg/m3 = 61,218 lb/ft3
laju massa larutan = 16.199,05 kg/jam = 35.712,749 lb/jam

1. Menghitung Diameter Dan Tinggi Tangki


Volume cairan dalam mixing tank = m/ρ (C.25)
35.712,749 lb/jam
=
61,218 lb/ft3

= 583,367 ft3
Faktor keamanan fk = 20 %
Volume tangki = 700,04 ft3
Diameter tangki dan tinggi tangki :
Direncanakan :
-tinggi silinder : diameter (Hs:D) = 2:1
V = 1/4 π D2H (C.26)
700,04 ft3 = ¼ π D2 (2/1 D)
D = 8,108 ft
H = 16,21 ft
R = 4,05 ft =48,65 in
C-60

2. Menghitung Tebal Shell Dan Tutup Tangki


Bahan yang digunakan adalah stainless steel, dimana :
- Allowable Working Stress (S) = 12650 psia
- Efisiensi sambungan (E) = 0,8
- Faktor korosi = 0,13 – 0,5 mm/ tahun
- Diambil = 0,01 in/ tahun
- Umur alat = 15 tahun
- Tekanan operasi (Poperasi) = 1 atm = 14,7 psia
Tekanan desain, Pdesain
volume
Tinggi cairan dalam tangki, h = 1 (C.27)
πD2
4

700,04 ft3
=1 = 13,563 ft
x 3,14 x (8,108 ft)2
4
g
ρ. h.
gc
Pdesain = + Poperasi (C.28)
144
61,21 x 13,563 x 1
= + 14,7 psia
144
= 20,46 psia
Faktor keamanan 20 % Pdesain = 1,2 x 20,46 psia = 24,55 psia

Tebal shell, t
PR
t = +(c . n) dimana R = D/2 (Mc Cetta, 1993) (C.29)
SE-0,6 P
24,55 x 4,05
= + (0,01 x 20)
(12650 x 0,8)- (0,6 x 24,55)

= 0,318 in
Dari tabel 5.4, Brownell, 1979, dipilih tebal tangki standar ½ in.
3. Tebal tutup
Tebal tutup dianggap sama dengan tebal shell karena terbuat dari bahan
yang sama = ½ in
C.15 Perhitungan Heat Exchanger (HE-01)
C-61

Fungsi :Memanaskan larutan metil formiat dari suhu 30,31oC menjadi 65oC
Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
Shell Side Tube Side
ID = 29 inch Number and Length = 120, 15’0’’
Baffle Space = 24.65 inch OD, BWG, pitch = 1½ , 18 BWG, 17⁄8 inch
Passes = 2 Passes = 4

1. Heat balance:
Metil formiat,Q = 2.082.011.936,07 joule/jam = 1.973.366,31 btu/jam
Air ,Q = 2.082.011.936,07 joule/jam = 1.973.366,31 btu/jam

2. Fluida Dingin (Shell)


Laju alir fluida dingin, W = 16.199.0467 kg/jam = 35.712.7424 lb/jam
a. Temperatur awal (t1) = 30°C = 86.56°F
b. Temperatur akhir (t2) = 65°C = 149°F

3. Fluida Panas (Tube)


Laju alir fluida panas, W = 71.630.3545 kg/jam = 157.917.7122 lb/jam
a. Temperatur awal (T1) = 100°C = 212°F
b. Temperatur akhir (T2) = 60°C = 140°F

4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.1 Data Temperatur HE-01
Fluida panas Fluida Dingin Selisih
212°F T1 s.tinggi 149°F t2 36°F
140°F T2 s.rendah 86,56°F t1 53°F
72°F T1-T2 Selisih 89,44°F t2 - t1 17°F

a. Menghitung ΔTLMTD
C-62

(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t ) (C.30)
ln 2
(T2- t )
1

(212℉ – 149℉ )- (140℉ – 86,56℉ )


= (212℉ – 149℉ )
ln (
(140℉ – 86,56℉ )

36℉ – 53℉
= 36℉
ln ( )
53℉

= 44,1473ºF
𝑇1 −𝑇2
b. R = (C.31)
𝑡2 −𝑡1
212℉ -140℉
=
149℉-86,56℉

= 0,8050 ºF
𝑡2 − 𝑡1
c. S = (C.32)
𝑇1 − 𝑡1
176℉- 86,56℉
=
212℉-86,56℉

= 0,713°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,845 maka,
d. Δt = FT . LMTD (C.33)
Δt = 0,845 × 44,1473℉
= 37,3045oF

b. Menghitung Temperatur Kalorik Tc dan tc


T1 + T2
Tc = (C.34)
2
212℉ + 140℉
=
2
= 176oF
t1 + t2
tc = (C.35)
2
86,56℉ + 149℉
=
2
= 131,28oF
C-63

Cek viskositas pada terminal dingin untuk tiap fluida


Tube :
Pada T = 176ºF
Μ = 0,279 cP (Fig. 15, Kern, 1965)
Shell :
Pada t = 131,28ºF
μ = 0,3134 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg

c. Pemilihan Jenis Alat Perpindahan Panas


Hot fluid = Tube
Cold fluid = Shell
Untuk campuran metil formiat dipilih light organics dengan :
Range Ud = 40 - 75 Btu/hr.ft2 ºF ( Tabel 8, Kern, 1965)
Ud dipilih = 75 Btu/hr.ft2 ºF
d. Luas permukaan untuk perpindahan panas
Q
A = (C.36)
UD . Δt
1.973.366,31 Btu/jam
=
(75 Btu/jam.ft2 .℉ )( 37,3045 ℉)

= 705,318 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 1/2 in
Diameter dalam tube (ID) = 1,4 in
Jenis tube = 18 BWG
Pitch (PT) = 1 7/8 in square pitch
C-64

Panjang tube, L = 15 ft
Luas permukaan luar (a”) = 0, 3925 ft2/ft

e. Jumlah tube
A
Nt = (C.37)
L . a''

705,318 ft2
=
(15 ft)(0,3925 ft2 /ft)

= 119,7992 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 120 buah tube dengan OD tube 1 1/2 in, 17/8 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = square pitch
b. Jumlah aliran, n = 2 aliran (passes)
c. Pitch, PT = 1 7/8 in = 0,16 ft
d. Diameter shell, ID = 29 in = 2,4166 ft
e. Baffle Space = 0,85 × 29 in = 24,65 in
f. C = PT – OD tube
= 0,38 in
g. A Terkoreksi = Nt . L . a (C.38)
= 119,7992×15 ft ×0,3925 ft2/ft
= 705,318 ft2
h. Ud Terkoreksi
Q
UD = (C.39)
A . t
1.973.366,31 Btu/jam
= 2
705,318 ft . 37,3045°F

= 75 Btu/jam.ft2.oF

f. Analisa Kinerja HE

Analisa kinerja HE meliputi :


C-65

1) Menghitung Koefisien Overall Perpindahan Panas (U)


2) Menghitung Rd
3) Menghitung ∆P

1) Menghitung Koefisien Overall Perpindahan Panas


a. Menghitung Flow area
Tube
Nt . a't
at = (C.40)
144 . n
119,7992 × 1,54
=
144 × 4
= 0,3203 ft2 (Tabel.10, Kern,1965)
Shell
½ ID × C' × B
as = (C.41)
144 × PT

½ 29 ft × 0,38 ft ' ×24,65 ft


=
144 × 1,875ft

= 0,5 ft2

b. Menghitung Mass Velocity


Tube :
W
Gt = (C.42)
at
157.917.7122 lb/jam
=
0,3202 ft2

= 493.035,9058 lbm/jam ft2


Shell :
W
Gs = (C.43)
as
35.712.7424 lb/jam
=
0,5 ft2

= 71.940,0561 lb/jam ft2


C-66

c. Menghitung Bilangan Reynold Number


Tube :
Viskositas pada Tc = 176°F
μ liquid = 0,279 cP (Fig. 15, Kern,1965)
= 0,6749 lb/ft.jam
de
Dc = (C.44)
12
1,4
=
12
= 0,1166 ft (Table. 10, Kern,1965)
Dc ×Gt
Ret = (C.45)
μ

0,1166 ft × 493.035,9058 lbm/jam ft2


=
0,6749 lbm/ft.jam
= 85225.4706 ft
15 ft
L/D = (C.46)
0,1166 ft

= 128,4706
jH = 200 (Fig. 24, Kern,1965)
Shell :
Viskositas pada tc = 131,28ºF
μ liquid = 0,3134 cP (Fig. 14, Kern, 1965)
= 0,7581 lb/ft.jam
1,48
Dc =
12
= 0,1233 ft (Fig. 28, Kern,1965)
D ×Gs
Res = (C.47)
μ
0,1233 ft × 71.940,0561 lb/jam ft2
=
0,7581 lb/ft.jam

= 11.703,0894 ft
jH = 60 (Fig. 28, Kern,1965)
d. Menentukan Thermal Function
Tube :
C-67

Viskositas pada Tc = 176°F


μ liquid = 0,279 cP (Fig. 15, Kern,1965)
= 0,6749 lb/ft.jam
Kapasitas panas, Cp :
Cp = 0,9 Btu/lb oF (Fig. 2, Kern,1965)
k = 0,3933 Btu/jam.lbm.ft. oF (Tabel 5, kern,1965)
1
c.μ
Pr = ( )3 (C.48)
k
0,9Btu/lb°F ×0,6749 lb/ft.jam )1/3
=(
0,3933 Btu/jam.lbm.ft.°F

= 0,5148 Btu/(hr) (ft2) (ºF/ft)


Shell :
Viskositas pada tc = 131,28ºF
μ liquid = 0,3134 cP (Fig. 14, Kern)
= 0,7581 lb/ft.jam
Kapasitas panas, Cp :
Cp = 0,4669 Btu/lb. ºF (Fig. 2, Kern,1965)
K = 0,1047 Btu/(hr) (ft2) (ºF/ft) (Table 4, Kern,1965)
1
c.μ
Pr = ( )3 (C.49)
k
0,4669 Btu/lb. ºF×0,7581 lb/ft.jam 1/3
=( )
0,1047 Btu/(hr) (ft2) (ºF/ft)

= 1,1262 Btu/(hr) (ft2) (ºF/ft)

e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film Coefficient
(ho)
Tube :
1
ℎ𝑖 k c. μ 3
∅𝑡
= jH ( D) ( k ) (C.50)

0,3933 Btu/jam.lbm.ft. ºF
= 200 × ( ) × 0,5148 Btu/(hr) (ft2) (ºF/ft)
0,1166 ft

= 160,0567 Btu/hr.ft2. ºF
C-68

1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡 (C.51)
c

= 160,0567 Btu/hr.ft2. ºF x 0,9468


= 151,5559 Btu/hr.ft2. ºF

Shell :
1
ℎ𝑜 k c. μ 3
∅𝑠
= jH (De) ( k ) (C.52)

0,1047 Btu/(hr) (ft2) (ºF/ft)


= 60 x ( ) x 1,1262 Btu/(hr) (ft2) (ºF/ft)
0,1233 ft

= 215,4931 Btu/hr.ft2. ºF
k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k

(C.53)
= 215,4931 Btu/hr.ft2. ºF × 0,7829
= 168,7132 Btu/hr.ft2. ºF

f. Menghitung Corrected Coefficient (hio)


Tube :
ℎio hi ID
= x (C.54)
∅𝑡 ∅t OD
1,4 inch
= 160,0567 Btu/hr.ft2. ºF x 1,5 inch

= 149.39 Btu/hr.ft2. ºF
ID
hio = hi × x ∅𝑡 (C.55)
OD
= 149.39 Btu/hr.ft2. ºF x 0,9468
= 141,5 Btu/hr.ft2. ºF
Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).

g. Menghitung Temperatur Wall


ho
∅s
tw = tc + hio ho (Tc - tc) (C.56)
+
∅t ∅s
C-69

215,4931 Btu/hr.ft2. ºF
= 131,28ºF + x
149.39 Btu/hr.ft2. ºF+ 215,4931 Btu/hr.ft2. ºF

(176 ºF - 131,28ºF)
= 158,2781ºF
Tube :
Pada tw = 158,2781ºF, µw = 0,412 cp (Fig. 14, Kern,1965)
= 0,9966 lb/ft.jam
𝜇
Sehingga, ∅𝑡 = (𝜇𝑤)0,14 (C.57)

0,6749 lb/ft.jam 0,14


=( )
0,9966 lb/ft.jam

= 0,9468
Shell;
Pada tw = 158,2781ºF, µw = 1,8 cp (Fig. 14, Kern,1965)
= 4,3543 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14 (C.58)
μw
0,7581 lb/ft.jam 0,14
=( )
4,3543 lb/ft.jam

= 0,7829
Menghitung Clean Overall Coefficient (Uc)
hio × ho
Uc = (C.59)
hio + ho
141,5 Btu/hr.ft2.ºF × 168,7132 Btu/hr.ft2. ºF
=
41,5 Btu/hr.ft2.ºF + 168,7132 Btu/hr.ft2. ºF

= 76,9423 Btu/hr.ft2.ºF

2) Menghitung Dirt Factor (Rd)


1 1
= 𝑈𝑐 + Rd (C.60)
𝑈𝑑
Uc - Ud
Rd =
Uc × Ud
2
76,9423 Btu/hr.ft2.ºF - 75 Btu/hr.ft . ºF
= 2
76,9423 Btu/hr.ft2.ºF x 75 Btu/hr.ft . ºF

= 0,0036 Btu/hr.ft2.ºF
C-70

Rd yang diperlukan = 0,002 Btu/hr.ft2.ºF (Table. 12, Kern,1965)

3) Menghitung Pressure Drops (∆P)


a. Tube :
1. Menetukan Faktor Friksi (f)
Ret = 85.225,4706 ft
ft2
f = 0,00016 in2 (Fig. 26, Kern,1965)

s = 0,9597 (Fig. 6, Kern,1965)


ϕt = 0,9468 (Fig. 24, Kern,1965)

2. Menentukan Pressure Drop Tube


2
f × Gt × L × n
a. ∆Pt = (C.61)
5,22 × 1010 × D × s × ϕt

ft2 lb
0,00016 × (493.035,9058 ) 2 × 15 × 4
in2 jam.ft2
=
5,22 × 1010 × 0,1166 ft × 0,9597 × 0,9468

= 0,2108 psi
V2
= 0,033 psi (Fig. 27, Kern,1965)
2g′
V2
4×n
b. ∆Pr = × 2g' (C.62)
s

4×4
= × 0,033 psi
0,9597

= 0,2750 psi
∆Ptotal = ∆Pt + ∆Pr (C.63)
= 0,2108 psi + 0,2750 psi
= 0,4858 psi
∆Pt < 10 psi (memenuhi)
b. Shell :
1. Menentukan Faktor Friksi (f)
Res = 11.703 ft
ft2
f = 0,002 in2 (Fig. 29, Kern,1965)
C-71

s = 0,9479 (Fig. 6, Kern,1965)


ϕs = 0,7829 (Fig. 24, Kern, 1965)
2. Menghitung Pressure Drop Shell
fGs 2 IDShell (N+1)
∆Ps = (C.64)
5,55 × 1010 Dc s ϕs
2
ft2 lb
0,002 2 × (71.940 ) × (2,4166 ft)x 7,3022
in hr.ft2
= 10
5,55 × 10 × (0,1233 ft) × 0,9479× 0,7829

= 0,0359 psi
∆Ps < 10 psi (memenuhi)

3. Menghitung Jumlah Baffle (Sekat)


L
N+1 = 12 × B (C.65)
15 ft
= 12 ×
24,65 in

= 7,3022 in
C.16 Perhitungan Heat Exchanger (HE-02)
Fungsi :Mendinginkan larutan metil formiat dan metanol dari suhu 82,81oC
menjadi 40oC
Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
Shell Side Tube Side
ID = 21,25 inch Number and Length = 111, 15’0’’
Baffle Space = 18,0625 inch OD, BWG, pitch = 1 1/4 , 18 BWG, 19⁄16
Passes = 2 inch
Passes = 4

1. Heat balance:
Metil formiat dan metanol ,
Q = 376.039.276,51 joule/jam = 356.416,42 btu/jam
Air ,Q = 376.039.276,51 joule/jam = 356.416,42 btu/jam
2. Fluida Dingin (tube)
C-72

Laju alir fluida dingin, W = 16.373.42 kg/jam = 36.097.16 lb/jam


a. Temperatur awal (t1) = 30°C = 86°F
b. Temperatur akhir (t2) = 50°C = 122°F
3. Fluida Panas (shell)
Laju alir fluida panas, W = 9.366,52 kg/jam = 20.649,61 lb/jam
a. Temperatur awal (T1) = 82,81°C = 181,05°F
b. Temperatur akhir (T2) = 40°C = 104°F
c. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.2 Data Temperatur HE-02
Fluida panas Fluida Dingin Selisih
181,5°F T1 s.tinggi 122°F t2 7,2°F
104°F T2 s.rendah 86°F t1 18°F
25,2°F T1-T2 Selisih 36°F t2 - t1 11°F

a. Menghitung ΔTLMTD
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1
(181,5℉ – 122℉ )- (104℉ – 86℉ )
= (181,5℉ – 122℉ )
ln (
(104℉ – 86℉ )

7,2℉ – 18℉
= 7,2℉
ln ( )
18℉

= 11,7866ºF

T1 -T2
b. R =
t2 -t1
129,2℉ -104℉
=
122℉-86℉
= 0,7 ºF
t2 - t1
c. S =
T1 - t1
C-73

122℉- 86℉
=
181,5℉-86℉

= 0,833°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,74 maka,
d. Δt = FT . LMTD
Δt = 0,74 × 11,7866℉
= 8,7221oF

b. Menghitung Temperatur Kalorik Tc dan tc


T1 + T2
Tc = 2
181,5℉ + 104℉
=
2
= 116,6oF
t1 + t2
tc =
2
86℉ + 122℉
=
2
o
= 104 F
Cek viskositas pada terminal dingin untuk tiap fluida
Shell :
Pada T = 116,6ºF
μ = 0,3686 cP (Fig. 15, Kern, 1965)

Tube :
Pada t = 104ºF
μ = 0,7972 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg

c. Pemilihan Jenis Alat Perpindahan Panas


Hot fluid = Shell
C-74

Cold fluid = Tube


Untuk campuran metil formiat dipilih light organics dengan :
Range Ud = 40 - 75 Btu/hr.ft2 ºF ( Tabel 8, Kern, 1965)
Ud dipilih = 75 Btu/hr.ft2 ºF

d. Luas permukaan untuk perpindahan panas


Q
A =𝑈
𝐷 . Δt

356.416,42 btu/jam
=
(75 Btu/jam.ft2 .℉ )( 8,7221℉)

= 544,8466 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 1/4 in
Diameter dalam tube (ID) = 1,15 in
Jenis tube = 18 BWG
Pitch (PT) = 1 9/16 in square pitch
Panjang tube, L = 15 ft
Luas permukaan luar (a”) = 0, 3271 ft2/ft

e. Jumlah tube
A
Nt =
L . a''

544,8466 ft2
=
(15 ft)(0,3271 ft2 /ft)

= 111,0548 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 111 buah tube dengan OD tube 1 1/4 in, 19/16 in Tringular pitch untuk 4
passes (Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = Tringular pitch
C-75

b. Jumlah aliran, n = 2 aliran (passes)


c. Pitch, PT = 1 9/16 in = 1,5625 ft
d. Diameter shell, ID = 21,25 in = 1,7708 ft
e. Baffle Space = 0,85 × 21,25 in = 18,0625 in
f. C = PT – OD tube
= 0,31 in
g. A Terkoreksi = Nt . L . a
= 111,0548 ×15 ft ×0,3271 ft2/ft
= 544,8466 ft2
h. Ud Terkoreksi
Q
UD = A . t
356.416,42 btu/jam
= 544,8466 ft2 x 8,7221oF

= 75 Btu/jam.ft2.oF

f. Analisa Kinerja HE

Analisa kinerja HE meliputi :


1) Menghitung Koefisien Overall Perpindahan Panas (U)
2) Menghitung Rd
3) Menghitung ∆P

1) Menghitung Koefisien Overall Perpindahan Panas


a. Menghitung Flow area
Tube
Nt . a't
at =
144 . n
111,0548 × 1,04
=
144 × 4
= 0,2004 ft2 (Tabel.10, Kern, 1965)
Shell
C-76

½ ID × C' × B
as =
144 × PT

½ 21,25 ft × 0,31 ft ' ×18,0625 ft


=
144 × 1,5625 ft

= 0,27 ft2

b. Menghitung Mass Velocity


Tube :
W
Gt =
at
36.097.16 lb/jam
=
0,2004 ft2

= 180.036,1607 lbm/jam ft2


Shell :
W
Gs =
as
20.649,61 lb/jam
=
0,27 ft2

= 77.470,7092 lb/jam ft2

c. Menghitung Bilangan Reynold Number


Tube :
Viskositas pada Tc = 104°F
μ liquid = 0,7972 cP (Fig. 15, Kern, 1965)
= 1,9284 lb/ft.jam
de
Dc =
12
1,15
=
12
= 0,0958 ft (Table. 10, Kern, 1965)
Dc ×Gt
Ret =
μ
0,0958 ft × 180.036,1607 lbm/jam ft2
=
1,9284 lb/ft.jam
C-77

= 8.946,2218 ft
15 ft
L/D =
0,0958 ft

= 156,5217
jH = 39 (Fig. 24, Kern, 1965)

Shell :
Viskositas pada tc = 116,6ºF
μ liquid = 0,3686 cP (Fig. 14, Kern, 1965)
= 0,8917 lb/ft.jam
1.23
Dc =
12
= 0,0758 ft (Fig. 28, Kern, 1965)
D ×Gs
Res =
μ
0,0758 ft × 77.470,7092 lb/jam ft2
=
0,0.8917 lb/ft.jam

= 8.904,4133 ft
jH = 51 (Fig. 28, Kern, 1965)

d. Menentukan Thermal Function


Tube :
Viskositas pada Tc = 104°F
μ liquid = 0,7972 cP (Fig. 15, Kern, 1965)
= 1,9284 lb/ft.jam
Kapasitas panas, Cp :
Cp = 1 Btu/lb oF (Fig. 2, Kern, 1965)
k = 0,3572 Btu/jam.lbm.ft. oF (Tabel 5, kern, 1965)
1
c.μ
Pr = ( )3
k
1 Btu/lb°F ×1,9284 lb/ft.jam 1/3
=( )
0,3572 Btu/jam.lbm.ft.°F
C-78

= 1,7995 Btu/(hr) (ft2) (ºF/ft)


Shell :
Viskositas pada tc = 116,6ºF
μ liquid = 0,3686 cP (Fig. 14, Kern, 1965)
= 0,8917 lb/ft.jam
Kapasitas panas, Cp :
Cp = 0,7687 Btu/lb. ºF (Fig. 2, Kern, 1965)
K = 0,1055 Btu/(hr) (ft2) (ºF/ft) (Table 4, Kern, 1965)
1
c.μ
Pr = ( )3
k
00,7687 Btu/lb. ºF×0,6239 lb/ft.jam 1/3
=( )
0,1055 Btu/(hr) (ft2) (ºF/ft)

= 2,1657 Btu/(hr) (ft2) (ºF/ft)

e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film Coefficient
(ho)
Tube :
1
hi k c. μ 3
∅t
= jH ( D) ( k )
0,3572 Btu/jam.lbm.ft.°F
= 39 × ( ) × 1,7955 Btu/(hr) (ft2) (ºF/ft)
0,0958 ft

= 133,7427 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c

= 133,7427 Btu/hr.ft2. ºF x 1,0289


= 137,6201 Btu/hr.ft2. ºF
Shell :
1
ℎ𝑜 k c. μ 3
∅𝑠
= jH (De) ( k )
0,1055 Btu/(hr) (ft2) (ºF/ft)
= 51x( ) x 2,1657 Btu/(hr) (ft2)(ºF/ft)
0,0758 ft

= 384,9261,0223 Btu/hr.ft2. ºF
C-79

k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k

= 384,9261,0223 Btu/hr.ft2. ºF × 0,9040


= 365,8503 Btu/hr.ft2. ºF
f. Menghitung Corrected Coefficient (hio)
Tube :
hio hi ID
= x
∅t ∅t OD
1,15 inch
= 133,7427 Btu/hr.ft2. ºF x
1,25 inch

= 123,0433 Btu/hr.ft2. ºF
hio ID
hio = × x ∅𝑡
∅t OD

= 123,0433 Btu/hr.ft2. ºF x 1,0289


= 126.61 tu/hr.ft2. ºF

Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).


g. Menghitung Temperatur Wall
ho
∅s
tw = tc + hio ho (Tc - tc)
+
∅t ∅s

384,9261 Btu/hr.ft2. ºF
= 104ºF + x
123,0433 Btu/hr.ft2. ºF+ 384,9261 Btu/hr.ft2. ºF

(116,6 ºF - 104ºF)
= 113,4813ºF
Tube :
Pada tw = 113,4813ºF, µw = 0,65 cp (Fig. 14, Kern, 1965)
= 1,5724 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
1,9284 lb/ft.jam 0,14
=( )
1,5724 lb/ft.jam

= 1,0289
Shell;
C-80

Pada tw = 113,4813ºF, µw = 0,53 cp (Fig. 14, Kern, 1965)


= 1,2821 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14
μw

0,8917 lb/ft.jam
=( )0,14
1,2821 lb/ft.jam
= 0,9504
h. Menghitung Clean Overall Coefficient (Uc)
hio × ho
Uc =
hio + ho
126.61 Btu/hr.ft2.ºF ×329,1077 Btu/hr.ft2. ºF
=
126.61 Btu/hr.ft2.ºF +329,1077 Btu/hr.ft2. ºF

= 91,4347 Btu/hr.ft2.ºF

2) Menghitung Dirt Factor (Rd)


1 1
= + Rd
𝑈𝑑 Uc
Uc - Ud
Rd =
Uc × Ud
91,4347 Btu/hr.ft2.ºF - 75 Btu/hr.ft
2
. ºF
= 2 2
91,4347 Btu/hr.ft .ºF x 75 Btu/hr.ft . ºF

= 0,0060 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern, 1965)

3) Menghitung Pressure Drops (∆P)


a. Tube :
1. Menetukan Faktor Friksi (f)
Ret = 8.946,2218 ft
ft2
f = 0,00028 in2 (Fig. 26, Kern, 1965)

s = 1,0036 (Fig. 6, Kern, 1965)


ϕt = 1,0289 (Fig. 24, Kern, 1965)

2. Menentukan Pressure Drop Tube


C-81

2
f × Gt × L × n
a. ∆Pt =
5,22 × 1010 × D × s × ϕt
ft2 lb
0,00028 × (180.036,1607 ) 2 × 15 × 4
in2 jam.ft2
=
5,22 × 1010 × 1,15 × 0,0958 ft × 1,0289

= 0,0527 psi
V2
= 0,0048 psi (Fig. 27, Kern, 1965)
2g′
V2
4×n
b. ∆Pr = × 2g'
s

4×4
= × 0,0048 psi
0,0958

= 0,0382 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0527 psi + 0,0382 psi
= 0,0909 psi
∆Pt < 10 psi (memenuhi)

b. Shell :
d. Menentukan Faktor Friksi (f)
Res = 8.904,4133 ft
ft2
f = 0,0023 in2 (Fig. 29, Kern, 1965)

s = 0,0119 (Fig. 6, Kern, 1965)


ϕs = 0,9504 (Fig. 24, Kern, 1965)
e. Menghitung Pressure Drop Shell
fGs 2 IDshell (𝑁+1)
∆Ps =
5,55 × 1010 Dc s ϕs

ft2 lb 2
0,0023 × (77.470,7092 ) × 1,7708 ft (9,9653 in)
in2 hr.ft2
= 10
5,55 × 10 × (0,1025 ft) × 0,0119 × 0,9504

= 3,8535 psi
∆Ps < 10 psi (memenuhi)

C.17 Perhitungan Heat Exchanger (HE-03)


C-82

Fungsi :Mendinginkan metanol dari suhu 62,91oC menjadi 40oC


Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
Shell Side Tube Side
ID = 19,25 inch Number and Length = 114, 18’0’’
Baffle Space = 16,3625 inch OD, BWG, pitch = 1, 13 BWG, 19⁄16 inch
Passes = 2 Passes = 4
1. Heat balance:
Metanol,Q = 744.297.884,66 joule/jam = 705.458,19 btu/jam
Air ,Q = 744.297.884,66 joule/jam = 705.458,19 btu/jam
2. Fluida Dingin (tube)
Laju alir fluida dingin, W = 7.784,32 kg/jam = 17.161,48 lb/jam
a. Temperatur awal (t1) = 30°C = 86°F
b. Temperatur akhir (t2) = 50°C = 122°F

3. Fluida Panas (shell)


Laju alir fluida panas, W = 7.819,87 kg/jam = 17.239,84 lb/jam
a. Temperatur awal (T1) = 54°C = 145,2°F
b. Temperatur akhir (T2) = 40°C = 104°F

4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.3 Data Temperatur HE-03
Fluida panas Fluida Dingin Selisih
145,2°F T1 s.tinggi 122°F t2 23,2°F
104°F T2 s.rendah 86°F t1 18°F
41,2°F T1-T2 Selisih 36°F t2 - t1 -5°F

a. Menghitung ΔTLMTD
C-83

(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1

(145,2℉ – 122℉ )- (104℉ – 86℉ )


= 145
(,2℉ – 122℉ )
ln (
(104℉ – 86℉ )

23,2℉ – 18℉
= 23,2℉
ln ( )
18℉

= 20,4901ºF
𝑇 −𝑇
b. R = 𝑡1 −𝑡2
2 1

145,2℉ -104℉
=
122℉-86℉
= 1,1444 ºF
t2 - t1
c. S =
T1 - t1
122℉- 86℉
=
145,2℉-86℉

= 0,608°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,852 maka,
d. Δt = FT . LMTD
Δt = 0,852 × 20,4901℉
= 17,4576oF

b. Menghitung Temperatur Kalorik Tc dan tc


T 1 + T2
Tc =
2
145,2℉ + 104℉
=
2
o
= 124,6 F
t1 + t2
tc =
2
86℉ + 122℉
=
2
o
= 104 F
Cek viskositas pada terminal dingin untuk tiap fluida
C-84

Shell :
Pada T = 124,6ºF
μ = 0,3344 cP (Fig. 15, Kern, 1965)

Tube :
Pada t = 104ºF
μ = 0,7972 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg

c. Pemilihan Jenis Alat Perpindahan Panas


Hot fluid = Shell
Cold fluid = Tube
Untuk metanol dipilih light organics dengan :
Range Ud = 40 - 75 Btu/hr.ft2 ºF ( Tabel 8, Kern, 1965)
Ud dipilih = 75 Btu/hr.ft2 ºF

d. Luas permukaan untuk perpindahan panas


Q
A =
UD . Δt
705.458,19 btu/jam
=
(75 Btu/jam.ft2 .℉ )( 17,45℉)

= 538,7972 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 in
Diameter dalam tube (ID) = 0,81 in
C-85

Jenis tube = 13 BWG


Pitch (PT) = 1 1/4 in square pitch
Panjang tube, L = 18 ft
Luas permukaan luar (a”) = 0, 2618 ft2/ft

e. Jumlah tube
A
Nt =
L . a''

538,7972 ft2
=
(18 ft)(0,2618 ft2 /ft)

= 114,3360 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 114 buah tube dengan OD tube 1 1/4 in, 19/16 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
a. Susunan tube = Square pitch
b. Jumlah aliran, n = 2 aliran (passes)
c. Pitch, PT = 1 1/4 in = 1,25 ft
d. Diameter shell, ID = 19,25 in = 1,6041 ft
e. Baffle Space = 0,85 × 19,25 in = 16,3625 in
f. C = PT – OD tube
= 0,25 in
g. A Terkoreksi = Nt . L . a
= 114,3360 ×18 ft ×0,2618 ft2/ft
= 538,7972 ft2
h. Ud Terkoreksi
Q
UD =
A . t
705.458,19 btu/jam
=
538,7972 ft2x 17,4576F

= 75 Btu/jam.ft2.oF
f. Analisa Kinerja HE
C-86

Analisa kinerja HE meliputi :


1) Menghitung Koefisien Overall Perpindahan Panas (U)
2) Menghitung Rd
3) Menghitung ∆P

1) Menghitung Koefisien Overall Perpindahan Panas


a. Menghitung Flow area
Tube
Nt . a't
at =
144 . n
114,3360, × 0,515
=
144 × 4
= 0,1022 ft2 (Tabel.10, Kern, 1965)
Shell
½ ID × C' × B
as =
144 × PT

½ 19,25 ft × 0,25 ft ' ×16,3625 ft


=
144 × 1,25 ft

= 0,22 ft2

b. Menghitung Mass Velocity


Tube :
W
Gt =
at
17.161,48 lb/jam
=
0,1022 ft2

= 167.875,2728 lbm/jam ft2


Shell :
W
Gs =
as
C-87

17.239,84 lb/jam
=
0,22 ft2

= 78.816,1732 lb/jam ft2

c. Menghitung Bilangan Reynold Number


Tube :
Viskositas pada Tc = 104°F
μ liquid = 0,7972 cP (Fig. 15, Kern, 1965)
= 1,9284 lb/ft.jam
de
Dc =
12
1,11
=
12
= 0,0675 ft (Table. 10, Kern, 1965)
Dc ×Gt
Ret =
μ
0,0675 ft × 167.875,2728 lbm/jam ft2
=
1,9284 lb/ft.jam

= 5.875.8606 ft
18 t
L/D =
0,0675 ft

= 266,6666
jH = 29 (Fig. 24, Kern, 1965)

Shell :
Viskositas pada tc = 124,6 ºF
μ liquid = 0,3344 cP (Fig. 14, Kern, 1965)
= 0,8090 lb/ft.jam
0,99
Dc =
12
= 0,0825 ft (Fig. 28, Kern, 1965)
D ×Gs
Res =
μ
C-88

0,0825 ft × 78.816,1732 lb/jam ft2


=
0,8090 lb/ft.jam

= 8.036,6079 ft
jH = 36 (Fig. 28, Kern, 1965)

d. Menentukan Thermal Function


Tube :
Viskositas pada Tc = 104°F
μ liquid = 0,7972 cP (Fig. 15, Kern, 1965)
= 1,9284 lb/ft.jam
Kapasitas panas, Cp :
Cp = 1 Btu/lb oF (Fig. 2, Kern, 1965)
k = 0,3572 Btu/jam.lbm.ft. oF (Tabel 5, Kern, 1965)
1
c.μ
Pr = ( )3
k
1 Btu/lb°F ×1,9284 lb/ft.jam 1/3
=( )
0,3572 Btu/jam.lbm.ft.°F

= 1,7995 Btu/(hr) (ft2) (ºF/ft)


Shell :
Viskositas pada tc = 124,6 ºF
μ liquid = 0,3344 cP (Fig. 14, Kern, 1965)
= 0,8090 lb/ft.jam
Kapasitas panas, Cp :
Cp = 0,8884 Btu/lb. ºF (Fig. 2, Kern, 1965)
K = 0,0946 Btu/(hr) (ft2) (ºF/ft) (Table 4, Kern, 1965)
1
c.μ
Pr = ( )3
k
0,8884 Btu/lb. ºF×0,8090 lb/ft.jam 1/3
=( )
0,0946 Btu/(hr) (ft2) (ºF/ft)

= 2,530 Btu/(hr) (ft2) (ºF/ft)


C-89

e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film


Coefficient (ho)
Tube :
1
ℎ𝑖 𝑘 𝑐. 𝜇 3
= jH (𝐷) ( 𝑘 )
∅𝑡

0,3572 Btu/jam.lbm.ft.°F
= 29 × ( ) ×1,7955 Btu/(hr) (ft2)
0,0675 ft

(ºF/ft)
= 126,7188 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c

= 126,7188Btu/hr.ft2. ºF x 1,0405
= 131,8619 Btu/hr.ft2. ºF
Shell :
1
ℎ𝑜 k c. μ 3
∅𝑠
= jH (De) ( k )
0,0946 Btu/(hr) (ft2) (ºF/ft)
= 36 x ( )x2,5301 Btu/(hr) (ft2)
0,0825 ft

(ºF/ft)
= 394,3904 Btu/hr.ft2. ºF
1
k c. μ 3
ho = jH (D ) ( k ) 1/3 ∅𝑠
c

= 394,3904 Btu/hr.ft2. ºF × 0,9452


= 372,8025 Btu/hr.ft2. ºF

f. Menghitung Corrected Coefficient (hio)


Tube :
hio hi ID
= x
∅t ∅t OD
0,81 inch
= 126,7188 Btu/hr.ft2. ºF x
1 inch
= 102,64 Btu/hr.ft2. ºF
C-90

ID
hio = hi × x ∅𝑡
OD
= 102,64 Btu/hr.ft2. ºF x 1,0405
= 106,81 Btu/hr.ft2. ºF
Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).
g. Menghitung Temperatur Wall
ℎ𝑜
∅𝑠
tw = tc + ℎ𝑖𝑜 ℎ𝑜 (Tc - tc)
+
∅𝑡 ∅𝑠

394,3904 Btu/hr.ft2. ºF
= 104ºF + x
102,64 Btu/hr.ft2. ºF+ 394,3904 Btu/hr.ft2. ºF

(124,6 ºF - 104ºF)
= 120,2100 ºF
Tube :
Pada tw = 120,2100ºF, µw = 0,6 cp (Fig. 14, Kern,1965)
= 1,4514 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
1,928 lb/ft.jam
=( )0,14
1,4514 lb/ft.jam

= 1,0405
Shell;
Pada tw = 120,2100ºF, µw = 0,5 cp (Fig. 14, Kern,1965)
= 1,2095 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14
μw
0,8090 lb/ft.jam 0,14
=( )
1,2095 lb/ft.jam

= 0,9452

h. Menghitung Clean Overall Coefficient (Uc)


hio × ho
Uc =
hio + ho
106,81 Btu/hr.ft2.ºF × 372,8025 Btu/hr.ft2. ºF
=
106,81 Btu/hr.ft2.ºF + 372,8025 Btu/hr.ft2. ºF
C-91

= 83,0222 Btu/hr.ft2.ºF

4) Menghitung Dirt Factor (Rd)


1 1
= + Rd
𝑈𝑑 Uc
Uc - Ud
Rd =
Uc × Ud
83,0222 Btu/hr.ft2.ºF - 75 Btu/hr.ft
2
. ºF
= 2 2
83,0222 Btu/hr.ft .ºF x 75 Btu/hr.ft . ºF

= 0,0012 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)

5) Menghitung Pressure Drops (∆P)


5. Tube :
1. Menetukan Faktor Friksi (f)
Ret = 5.875,8606 ft
ft2
f = 0,00016 (Fig. 26, Kern,1965)
in2

s = 0,9597 (Fig. 6, Kern,1965)


ϕt = 1,0405 (Fig. 24, Kern,1965)

3. Menentukan Pressure Drop Tube


2
f × Gt × L × n
c. ∆Pt =
5,22 × 1010 × D × s × ϕt

ft2 lb
0,00016 × (167.875,2728 ) 2 × 18 × 4
in2 jam.ft2
=
5,22 × 1010 × 0.675 × 0,9597 ft × 1,0405

= 0,0461 psi
2
V

2g' = 0,01 psi (Fig. 27, Kern,1965)

V2
4×n
d. ∆Pr = × 2g'
s
4×4
= × 0,001 psi
0,09597
C-92

= 0,00833 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0461 psi + 0,00833 psi
= 0,1294 psi
∆Pt < 10 psi (memenuhi)

2. Shell :
d. Menentukan Faktor Friksi (f)
Res = 8.036,6079 ft
ft2
f = 0,002 in2 (Fig. 29, Kern,1965)

s = 0,9479 (Fig. 6, Kern,1965)


ϕs = 0,9452 (Fig. 24, Kern,1965)
e. Menghitung Pressure Drop Shell
fGs 2 IDshell (𝑁+1)
∆Ps =
5,55 × 1010 Dc s ϕs

ft2 lb 2
0,002 × (78.816,1732 ) × 1,6041 ft (13,200 in)
in2 hr.ft2
=
5,55 × 1010 × (0,0825 ft) × 0,9479 × 0,9452

= 0,0641 psi
∆Ps < 10 psi (memenuhi)

f. Menghitung Jumlah Baffle (Sekat)


L
N+1 = 12 ×
B
18 ft
= 12 ×
16,3625 in

= 13,200 in

C.18 Perhitungan Heat Exchanger (HE-04)


Fungsi :Mendinginkan Asam Formiat dari suhu 142oC menjadi 30oC
Tipe : 2-4 Shell and Tube Exchanger
Dipakai :
C-93

Shell Side Tube Side


ID = 25 inch Number and Length = 238, 18’0’’
Baffle Space = 21,25 inch OD, BWG, pitch = 1, 18 BWG, 11⁄4 inch
Passes = 2 Passes = 4
1. Heat balance:
Asam Formiat ,Q = 3.135.590.361,67 joule/jam = 2.971.965,85 btu/jam
Air ,Q = 3.135.590.361,67 joule/jam = 2.971.965,85btu/jam
2. Fluida Dingin (tube)
Laju alir fluida dingin, W = 9.093,40 kg/jam = 20.047,49 lb/jam
c. Temperatur awal (t1) = 25°C = 77°F
d. Temperatur akhir (t2) = 80°C = 176°F

3. Fluida Panas (shell)


Laju alir fluida panas, W = 11.379,36 kg/jam = 25.087,17 lb/jam
c. Temperatur awal (T1) = 142°C = 289,2°F
d. Temperatur akhir (T2) = 30°C = 86°F

4. ∆t
∆𝑡 = beda suhu sebenarnya
Tabel C.4 Data Temperatur HE-04
Fluida panas Fluida Dingin Selisih
289,2°F T1 s.tinggi 176°F t2 113,2°F
86°F T2 s.rendah 77°F t1 9°F
203,2°F T1-T2 Selisih 99°F t2 - t1 -104°F
a. Menghitung ΔTLMTD
(T1- t )- (T2 - t )
2 1
a. LMTD = (T1- t )
ln 2
(T2- t )
1
(289,2℉ – 176℉)- (86℉ – 77℉ )
= (289,2℉ – 176℉)
ln (
(86℉ – 77℉ )

113,2℉ – 9℉
= 113,2℉
ln ( )
9℉
C-94

= 41,1543ºF
T1 -T2
g. R =
t2 -t1
289,2℉ -86℉
=
176℉-77℉
= 2,0525 ºF
t2 - t1
h. S =
T1 - t1
176℉- 77℉
=
289,2℉-77℉

= 0,467°F
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,467 maka,
i. Δt = FT . LMTD
Δt = 0,467 × 41,1543℉
= 35,3927oF

a. Menghitung Temperatur Kalorik Tc dan tc


T1 + T 2
Tc =
2
289,2℉ + 86℉
=
2
= 187,6oF
t1 + t2
tc =
2
77℉ + 1176℉
=
2
= 126,5oF
Cek viskositas pada terminal dingin untuk tiap fluida
Shell :
Pada T = 187,6ºF
μ = 0,3015 cP (Fig. 15, Kern, 1965)

Tube :
Pada t = 126,5ºF
C-95

μ = 0,8904 cP (Fig. 15, Kern, 1965)


Karena viskositas fluida pada terminal dingin < 1 cp (Kern, 1965, Hal: 111),
maka:
Tc = Tavg
tc = tavg

b. Pemilihan Jenis Alat Perpindahan Panas


Hot fluid = Shell
Cold fluid = Tube
Untuk asam formiat dipilih light organics dengan :
Range Ud = 40 - 75 Btu/hr.ft2 ºF ( Tabel 8, Kern, 1965)
Ud dipilih = 75 Btu/hr.ft2 ºF

c. Luas permukaan untuk perpindahan panas


Q
A =
UD . Δt

2.971.965,85 btu/jam
=
(75 Btu/jam.ft2 .℉ )( 35,3927℉)
= 1119,6140 ft2
Karena surface area (A) > 200 ft2, maka direncanakan tipe Shell and Tube
Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4 shell and tube
heat exchanger dengan spesifikasi:
Diameter luar tube (OD) = 1 in
Diameter dalam tube (ID) = 0,81 in
Jenis tube = 18 BWG
Pitch (PT) = 1 1/4 in square pitch
Panjang tube, L = 18 ft
Luas permukaan luar (a”) = 0, 2618 ft2/ft

d. Jumlah tube
A
Nt =
L . a''
C-96

1119,6140 ft2
=
(18 ft)(0,2618 ft2 /ft)

= 237,5889 tube
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih jumlah
tube = 238 buah tube dengan OD tube 1 in, 1 1/4 in Square pitch untuk 4 passes
(Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
i. Susunan tube = Square pitch
j. Jumlah aliran, n = 2 aliran (passes)
k. Pitch, PT = 1 1/4 in = 1,25 ft
l. Diameter shell, ID = 25 in = 2,08333 ft
m. Baffle Space = 0,85 × 25 in = 21,25 in
n. C = PT – OD tube
= 0,25 in
o. A Terkoreksi = Nt . L . a
= 237,5889 ×18 ft ×0,2618 ft2/ft
= 1.119,6140 ft2
p. Ud Terkoreksi
Q
UD =
A . t
2.971.965,85 btu/jam
=
1.119,6140 ft2x 35,3927 F

= 75 Btu/jam.ft2.oF
e. Analisa Kinerja HE
Analisa kinerja HE meliputi :
1) Menghitung Koefisien Overall Perpindahan Panas (U)
2) Menghitung Rd
3) Menghitung ∆P

1) Menghitung Koefisien Overall Perpindahan Panas


a. Menghitung Flow area
Tube
C-97

Nt . a't
at =
144 . n
237,5889 × 0,515
=
144 × 4
= 0,2124 ft2 (Tabel.10, Kern,1965)

Shell
½ ID × C' × B
as =
144 × PT

½ 25 ft × 0,25 ft ' ×21,25 ft


=
144 × 1,25 ft

= 0,37 ft2

b. Menghitung Mass Velocity


Tube :
W
Gt =
at
20.047,49 lb/jam
=
0,2124 ft2

= 94.373 lbm/jam ft2


Shell :
W
Gs =
as
25.087,17 lb/jam
=
0,37 ft2

= 68.000,9825 lb/jam ft2

c. Menghitung Bilangan Reynold Number


Tube :
Viskositas pada Tc = 126,5°F
μ liquid = 0,8904 cP (Fig. 15, Kern,1965)
= 2,154 lb/ft.jam
de
Dc =
12
C-98

0,81
=
12
= 0,0675 ft (Table. 10, Kern,1965)
Dc ×Gt
Ret =
μ
0,0675 ft × 94.373 lbm/jam ft2
=
2,154 lb/ft.jam

= 2957,3109 ft
18 t
L/D =
0,0675 ft

= 266,6666
jH = 10 (Fig. 24, Kern,1965)

Shell :
Viskositas pada tc = 187,6 ºF
μ liquid = 0,3015 cP (Fig. 14, Kern,1965)
= 0,7295 lb/ft.jam
0,99
Dc =
12
= 0,0825 ft (Fig. 28, Kern,1965)
D ×Gs
Res =
μ
0,0825 ft × 68.000,9825 lb/jam ft 2
=
0,8090 lb/ft.jam

= 7.690,1582 ft
jH = 49 (Fig. 28, Kern,1965)

d. Menentukan Thermal Function


Tube :
Viskositas pada Tc = 126,5°F
μ liquid = 0,8904 cP (Fig. 15, Kern,1965)
= 2,154 lb/ft.jam
Kapasitas panas, Cp :
C-99

Cp = 0,99 Btu/lb oF (Fig. 2, Kern,1965)


k = 0,3530 Btu/jam.lbm.ft. oF (Tabel 5, Kern,1965)
1
c.μ
Pr = ( )3
k
0,99 Btu/lb°F ×2,154 lb/ft.jam 1/3
=( )
0,3530 Btu/jam.lbm.ft.°F

= 2,0134 Btu/(hr) (ft2) (ºF/ft)


Shell :
Viskositas pada tc = 187,6 ºF
μ liquid = 0,3015 cP (Fig. 14, Kern,1965)
= 0,7295 lb/ft.jam
Kapasitas panas, Cp :
Cp = 0,4160 Btu/lb. ºF (Fig. 2, Kern,1965)
K = 0,0952 Btu/(hr) (ft2) (ºF/ft) (Table 4, Kern,1965)
1
c.μ
Pr = ( )3
k
0,4160 Btu/lb. ºF×0,7295 lb/ft.jam 1/3
=( )
0,0952 Btu/(hr) (ft2) (ºF/ft)

= 1,0617 Btu/(hr) (ft2) (ºF/ft)

e. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film


Coefficient (ho)
Tube :
1
hi k c. μ 3
∅t
= jH ( D) ( k )
0,3530 Btu/jam.lbm.ft.°F
= 10 × ( ) × 2,0134 Btu/(hr) (ft2) (ºF/ft)
0,0675 ft

= 105,3091 Btu/hr.ft2. ºF
1
k c. μ 3
hi = jH (D ) ( k ) ∅𝑡
c

= 105,3091 /hr.ft2. ºF x 1,1037


= 116,2324 Btu/hr.ft2. ºF
C-100

Shell :
1
ho k c. μ 3
∅s
= jH (De) ( k )
0,0952 Btu/(hr) (ft2) (ºF/ft)
= 49 x ( ) x 1,061 Btu/(hr) (ft2) (ºF/ft)
0,0825 ft

= 60.0856 Btu/hr.ft2. ºF
k c × μ 1/3
ho = jH ( ) ( ) ∅𝑠
Dc k

= 60,0856 Btu/hr.ft2. ºF × 0,8723


= 52,414 Btu/hr.ft2. ºF
f. Menghitung Corrected Coefficient (hio)
Tube :
ℎ𝑖𝑜 hi ID
= x OD
∅𝑡 ∅t
0,81 inch
= 105,3091 Btu/hr.ft2. ºF x 1 inch

= 85,3004 Btu/hr.ft2. ºF
hi ID
hio = × x ∅𝑡
∅t OD

= 85,3004 Btu/hr.ft2. ºF x 1,1037


= 94.15 Btu/hr.ft2. ºF
Dimana ∅𝑡 dan ∅𝑠 diperoleh dari perhitungan tw (temperatur wall).

g. Menghitung Temperatur Wall


ho
∅s
tw = tc + hio ho (Tc - tc)
+
∅t ∅s

60.0856 Btu/hr.ft2. ºF
= 126,5ºF +
85,3004 Btu/hr.ft2. ºF+ 60.0856 Btu/hr.ft2. ºF

x (187,6ºF – 126,5ºF)
= 150,3030 ºF
Tube :
Pada tw = 150,3030F, µw = 0,44 cp (Fig. 14, Kern,1965)
C-101

= 1,0643 lb/ft.jam
μ
Sehingga, ∅𝑡 =( )0,14
μw
2,154 lb/ft.jam
=( )0,14
1,0643 lb/ft.jam

= 1,1037
Shell;
Pada tw = 150,3030ºF, µw = 0,8 cp (Fig. 14, Kern,1965)
= 1,9352 lb/ft.jam
μ
Sehingga, ∅𝑠 =( )0,14
μw
0,7295 lb/ft.jam 0,14
=( )
1,9352 lb/ft.jam

= 0,8723

h. Menghitung Clean Overall Coefficient (Uc)


hio × ho
Uc =
hio + ho
94.15 Btu/hr.ft2.ºF × 52,4145 Btu/hr.ft2. ºF
=
94,15 Btu/hr.ft2.ºF + 52,4145 Btu/hr.ft2. ºF

= 33,6697 Btu/hr.ft2.ºF

6) Menghitung Dirt Factor (Rd)


1 1
= 𝑈𝑐 + Rd
𝑈𝑑
Uc - Ud
Rd = Uc × Ud
33,6697Btu/hr.ft2.ºF - 75 Btu/hr.ft
2
. ºF
= 2 2
33,6697 Btu/hr.ft .ºF x 75 Btu/hr.ft . ºF

= -0,0163 Btu/hr.ft2.ºF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)

7) Menghitung Pressure Drops (∆P)


Tube :
1. Menetukan Faktor Friksi (f)
C-102

Ret = 2.957,3109 ft
ft2
f = 0,00038 (Fig. 26, Kern,1965)
in2

s = 1,0073 (Fig. 6, Kern,1965)


ϕt = 1,1037 (Fig. 24, Kern,1965)

2. Menentukan Pressure Drop Tube


2
f × Gt × L × n
a. ∆Pt =
5,22 × 1010 × D × s × ϕt
ft2 lb
0,00038 × (94.373,2909 ) 2 × 18 × 4
in2 jam.ft2
=
5,22 × 1010 × 0.675 × 1,0073 ft × 1,1037

= 0,0311 psi
V2
= 0,001 psi (Fig. 27, Kern,1965)
2g′
V2
4×n
b. ∆Pr = × 2g'
s
4×4
= × 0,001 psi
1,0073

= 0,0079 psi
∆Ptotal = ∆Pt + ∆Pr
= 0,0311 psi + 0,0079 psi
= 0,0390 psi
∆Pt < 10 psi (memenuhi)
Shell :
1. Menentukan Faktor Friksi (f)
Res = 7.690,1582 ft
ft2
f = 0,0026 in2 (Fig. 29, Kern,1965)

s = 1,0119 (Fig. 6, Kern,1965)


ϕs = 0,8923 (Fig. 24, Kern,1965)
g. Menghitung Pressure Drop Shell
fGs 2 IDshell (𝑁+1)
∆Ps =
5,55 × 1010 Dc s ϕs
C-103

ft2 lb 2
0,0026 × (68.000,9825 ) × 2,0833 ft (10,1647 in)
in2 hr.ft2
= 10
5,55 × 10 × (0,0825 ft) x 1,0119 × 0,8923

= 0,0629 psi
∆Ps < 10 psi (memenuhi)

h. Menghitung Jumlah Baffle (Sekat)


L
N+1 = 12 ×
B
18 ft
= 12 ×
21,25 in

= 10,1647 in

C.19 Menara Distilasi (D-01)


Fungsi : Memisahkan Asam Formiat dari Campuran Metil Formiat dan
Air
Tipe : Sieve Tray Tower
C-104

Input CD-01

RB-01
Gambar C.1 Menara Distilasi D-01

Perhitungan ini dilakukan untuk mengetahui spesifikasi Menara Distilasi


(D-01), yang meliputi:
1. Kondisi operasi
2. Spesifikasi shell (diameter, tinggi dan tebal) dan head menara
3. Spesifikasi tray
4. Cek kondisi aliran (flooding dan weeping)
5. Isolasi (ketebalan)
6. Spesifikasi alat penunjang menara distilasi

A. Penentuan Tipe Kolom Distilasi


Dalam perancangan menara distilasi ini dipilih jenis Tray dengan
pertimbangan diameter kolom lebih dari 3 ft (0,91 m) (Walas, 1990). Sedangkan
jenis tray yang digunakan adalah sieve tray dengan pertimbangan:
1. Pressure drop rendah dan efesiensi tinggi (tab. 9.22, ludwig, 1980).
2. Lebih ringan, murah karena pembuatannya lebih mudah.
3. Biaya perawatan murah karena mudah dibersihkan.
B. Penentuan Bahan Konstuksi
Dipilih bahan konstruksi jenis Stainless SA 240 Grade B, dengan
pertimbangan:
1. Mempunyai allowable stress yang besar
C-105

2. Struktur kuat
3. Tahan terhadap korosifitas tinggi

C. Kondisi Operasi
Langkah-langkah perhitungannya adalah sebagai berikut:
1. Menentukan kondisi operasi atas dan bawah menara distilasi
2. Menentukan volatilitas rata-rata
3. Mengecek pemilihan light key component (LK) dan heavy key component
(HK) dengan persamaan Shira’s et. Al. pada Rm
KLK
α= (Coulson, 1983) (C.66)
KHK
αtop +αbottom
αAvg = (Coulson, 1983) (C.67)
2
4. Menghitung jumlah plate minimum dengan persamaan Fenske (R. Van
Wingkle;eg : 5.118 ; p 236)
Log[(XLK /XHK )D x (XHK /XLK )B ]
Nm= (Coulson, 1983) (C.68)
Log(αlk )

5. Mencari Refluks ratio minimum dengan persamaan Colburn & Underwood


1 Xd LK α(1-Xd LK)
RM = [ - ] (Coulson, 1983) (C.69)
α-1 XF LK (1-XF LK)

6. Menentukan lokasi feed plate dengan persamaan Kirkbride


m B X (X ) 2
Log =0,206 Log { ( HK ) [(X LK )B ] } (Coulson, 1983) (C.70)
p D X LK F HK D

1. Menentukan kondisi operasi atas dan bawah menara distilasi


Tabel C.5 Neraca Massa D-01
Neraca Neraca massa keluar
Komponen Fraksi (Xi)
massa masuk (kg/jam)
C-106

(kg/jam) Top Bottom Top Bottom

HCOOCH3 1604,90 1604,90 0,00 0,10 0,00


H2O 312,61 4,44 308,17 0,00 0,07
HCOOH 11070,25 7,06 11063,19 0,00 0,93
CH3OH 7758,12 7750,12 8,00 0,90 0,00

9366,52 11379,36
Total 20745,88 1,00 1,00
20745,88

Tekanan uap tiap komponen dihitung dengan menggunakan persamaan:


C2
P°=exp [C1 + +C3 ln T+C4 x TC5 ] (C.71)
T

Keterangan:
A, B, C, D, E = konstanta
P = tekanan uap komponen (pa)
T = tekanan (K)
Konstanta untuk tiap-tiap komponen dapat dilihat pada tabel berikut:
Tabel C.6 Konstanta Tekanan Uap
Komponen A B C D E
HCOOCH3 77,184 -5606,01 -8,392 7,85x10-6 2
H2O 73,649 -7258,2 -7,3037 4,17 x10-6 2
HCOOH 50,323 -5378,2 -4,203 3,47 x10-6 2
CH3OH 81,77 -6878 -8,7078 7,19 x10-6 2
Sumber: (Carl L. Yaws,2005)

Tabel C.7 Hasil Perhitungan Kondisi Umpan Kolom Distilasi (D-01)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)
C-107

HCOOCH3 67,68 26,73 0,05 1,535174669 0,07789195


H2O 6,87 17,35 0,03 0,155829751 0,00513367
HCOOH 6,94 240,53 0,46 0,157358973 0,07185679
CH3OH 10,65 242,12 0,46 0,241575254 0,11104615

Total 526,73 1,00 0,26592857

Tabel C.8 Hasil Perhitungan Top Produk Kolom Distilasi (D-01)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)

HCOOCH3 72,91 26,73 0,10 1,653812468 0,164307123


H2O 6,87 0,25 0,00 0,174412801 0,000159748
HCOOH 6,94 0,15 0,00 0,189583349 0,000108045
CH3OH 10,65 241,87 0,90 0,654107469 0,588149662

Total 269,00 1,00 0,752724578

Tabel C.9 Hasil Perhitungan Bottom Produk Kolom Distilasi (D-01)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)

HCOOCH3 275,58 0,0112 0,00 6,250590293 0,000000272


H2O 56,76 17,11 0,07 1,287380291 0,085447079
HCOOH 45,19 240,37 0,93 1,024914077 0,955895060
CH3OH 168,64 0,25 0,00 3,825182926 0,003704281

Total 257,73 1,00 1,045046692

C.1 Relatif Volatilitas Rata-Rata


αAvg = √αtop 𝑥 αbottom (C.72)
Keterangan :
C-108

αAvg = Volatilitas relatif rata-rata


αtop = Volatilitas relatif pada distilat
αbottom = Volatilitas relatif pada bottom
Dengan menggunakan persamaan tersebut diperoleh nilai αAvg sebagai berikut
Tabel C.10 Nilai αAvg tiap komponen

Komponen αAvg αtop αbottom


HCOOCH3 0,055 7,01 x 10-5
44,206
H2O 0,972 22,026
0,429
HCOOH 2,676 246,406
0,029
CH3OH 12,292 0,954
158,24

Total 15,997 202,158 269,387

A. Cek pemilihan light key (LK) dan heavy key (HK)


Adapun pemilihan komponen kunci adalah sebagai berikut
Light key : Metil Formiat
Heavy key : Asam Formiat
Menentukan distribusi komponen menggunakan Metode Shiras
xid x D (𝛼−1)𝑥 𝑋𝑙𝑘𝐷 𝑥 𝐷 (𝛼𝐿𝐾− 𝛼𝑖)𝑥 𝑋ℎ𝑘𝑑 𝑥 𝐷
= (𝛼𝐿𝐾−1)𝑥 𝑋𝑙𝑘𝑓 𝑥 𝐹 +
xif x F (𝛼𝐿𝐾−1)𝑥 𝑋 𝐻𝑘𝑓 𝑥 𝐹
xid x D
Komponen i terdistribusi jika -0,01≤ ( ) ≤1,01
xif x F
xid x D xid x D
Komponen i tak terdistribusi jika < -0,01 atau > 1,01
xif x F xif x F

Tabel C.11 Penentuan distribusi komponen


Komponen Xi, F Xi, D Xi, D x D Keterangan
Xi, F x F

HCOOCH3 0,05 0,10 0,0280 terdistribusi


H2O 0,03 0,00 0,413 terdistribusi
HCOOH 0,46 0,00 0,993 terdistribusi
CH3OH 0,46 0,90 0,413 terdistribusi

Total 257,73 1,00


C-109

Pemilihan light key dan heavy key tepat karena dari hasil perhitungan diatas metil
formiat dan asam formiat terdistribusi

C.2 Menentukan stage minimum


Dengan menggunakan metode Fenske

Log[(XLK /XHK )D x (XHK /XLK )B ]


NM = (C.73)
Log(αAvg )

NM = 10,718

C.3 Mencari Refluks ratio minimum


1 X LK α(1-Xd LK)
RM = α-1 [Xd LK - (1-XFLK)
] (C.74)
F

RM = 1,429

R operasi berkisar antara 1,2 – 1,5 Rm (Geankoplis, 1993)


Diambil Roperasi = 1,2 x Rm (C.75)
= 1,2 x 1,429
= 1,715
C.4 Penentuan Jumlah Stage
ROP
= 0,706
Rm +1
Rm
= 0,588
Rm +1
C-110

Gambar C.8 Grafik Penentuan Stage Ideal


Untuk menentukan jumlah plate teoritis digunakan korelasi Gilliland
sehingga didapat nilai R = 0,588.
Nm
= 0,62
N
Nm = 10,718
10,718
N =
0,62
N = 12,287

C.5 Feed Location


Feed location ditentukan dengan menggunakan metode Kirkbride.
m B X (X ) 2
Log p = 0,206 Log {D ( XHK ) [(X LK )B ] } (Coulson vol.6 Eq 11.62) (C.76)
LK F HK D
C-111

m
Log = 0,9
p
m
=9
p
m=9p

N = m+p
12 = 9 p+p
p =1
m = N-p
=12-1
=11

A. Menentukan Spesifikasi Menara Distilasi


1. Menentukan Sifat-sifat Fisika
Densitas pada suhu atas (355,96 K)
Tabel C.10 Hasil Perhitungan Densitas Liquid
Komponen BM Distilat yD, D ρ Liquid yD/ρi
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 1604,90 0,10 975 1,02 x 10-4
H2O 18,02 4,44 0,00 994,1 9,21 x 10-7
HCOOH 46,03 7,06 0,00 1226,47 4,65 x 10-7
CH3OH 32,04 7750,12 0,90 810 1,11 x 10-3

Total 9366,52 1,00 1,21 x 10-3

⅀yD
ρliquid = yD (C.78)

ρi

= 824,156 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
ρuap = (BM x P) /RT (C.79)
C-112

Tabel C.11 Hasil Perhitungan Densitas Uap


Komponen BM Distilat yD, D ρ Uap yD/ρi
(kg/kmol) (Kg/Jam) (kg/m3)

HCOOCH3 60,05 1604,90 0,10 2,0558937 0,04832474


H2O 18,02 4,44 0,00 0,6169393 0,00148462
HCOOH 46,03 7,06 0,00 1,5758998 0,00036164
CH3OH 32,04 7750,12 0,90 1,0969331 0,81970692

Total 9366,52 1,00 0,86987792

⅀yD
ρuap = yD (C.80)

ρi

= 1,149 kg/m3
Densitas pada suhu bawah (416,05 K)
Tabel C.12 Hasil Perhitungan Densitas Liquid
Komponen BM Bottom xB, B ρ Liquid xB/ρi
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 0,00 0,00 975 4,47 x 10-11
H2O 18,02 308,17 0,07 994,1 6,68 x 10-5
HCOOH 46,03 11063,19 0,93 1226,47 7,60 x 10-4
CH3OH 32,04 8,00 0,00 810 1,20 x 10-6

Total 11379,36 1,00 8,28 x 10-4

⅀xB
ρliquid = xB

ρi

= 1207,14 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
ρ uap = (BM x P) /RT
C-113

Tabel C.13 Hasil Perhitungan Densitas Uap


Komponen BM Bottom xB, B ρ Uap xB/ρ
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 0,00 0,00 1,758961434 2,475 x 10-8
H2O 18,02 308,17 0,07 0,527834888 0,12574545
HCOOH 46,03 11063,19 0,93 1,348293003 0,69173297
CH3OH 32,04 8,00 0,00 0,93850332 0,00103185

Total 11379,36 1,00 0,8185103

⅀xB
ρuap = xB

ρi

= 1,221 kg/m3
2. Menghitung Tegangan Permukaan
Tegangan permukaan dihitung dengan persamaan Sudgen:
Pch (𝜌𝐿−𝜌𝑣) 4
σ=[ ] x 10-12 (Coulson, 1983) (C.81)
𝑀
Keterangan :
σ = Tegangan permukaan (dyne/cm)
Pch = Sudgen’s parachor
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
M = Berat molekul (kg/kmol)
Tabel C.14 Data untuk menentukan Pch (Coulson, 1983)
Atom, group or bond Contribution Atom, group or bond Contribution
C 4,8 Si 25,0
H 17,1 Al 38,6
H in (OH) 11,3 Sn 57,9
O 20,0 As 50,1
O2 60,0 Double bond: terminal
N 12,5 2,3 position 23,2
C-114

S 48,2 3,4 position


P 37,7 Triple bond 46,6
F 25,7 Rings
Cl 54,3 3-membered 16,7
Br 68,0 4-membered 11,6
I 91,0 5-membered 8,5
Se 62,5 6-membered 6,1

Tabel C.15 Perhitungan σ top


Komponen BM yD, D Pch Σ yD x σ
(kg/kmol)
HCOOCH3 60,05 0,10 113,2 5,793572522 0,017148
H2O 18,02 0,00 54,2 37,5483439 0,000024
HCOOH 46,03 0,00 74,2 3,097879415 0,000184
CH3OH 32,04 0,90 93,2 32,84780902 0,027374

Total 1,00 0,044730


σ mix top = 0,044730 dyne/cm = 0,00004 N/m

Tabel C.16 Perhitungan σ bottom


Komponen BM yD, D Pch Σ yD x σ
(kg/kmol)
HCOOCH3 60,05 0,00 113,2 26,70583045 0,00000000163
H2O 18,02 0,07 54,2 173,0814108 0,000383
HCOOH 46,03 0,93 74,2 14,27986654 0,065313
CH3OH 32,04 0,00 93,2 151,4140049 0,000006

Total 1,00 0,065703


σ mix bottom = 0,065703 dyne/cm = 0,000065703 N/m
C-115

3. Menentukan Diameter Menara


Tinggi plate spacing pada umumnya antara 0,3-0,6 m (Coulson, 1983).
Diambil tray spacing = 0,4 m
1. Laju alir massa bagian atas
F = 20.745,88 kg/jam
D = 9.366,52 kg/jam
L = 9.366,52 kg/jam
V = 9.366,52 kg/jam

2. Laju alir massa bagian bawah


B = 11.379,36 kg/jam
L* = 12.639,844 kg/jam
V* = 11.379,36 kg/jam
3. Liquid-vapor flow factor
Lw ρL
FLV = √
V w ρv
(Coulson, 1983) ( C.82)

Keterangan :
FLV = Liquid-vapor flow factor
LW = Laju alir massa cairan (Kg/h)
VW = Laju alir massa uap (kg/h)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)

9366,52 1,149
FLV, top = √
9366,52 824,156

= 0,037
Untuk tray spacing = 0,4 m dan FLV = 0,037 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 top:
σ top 0,2
K1’ top = K1 [ ] (Coulson, 1983) (C.83)
0,02
0,00004 0,2
K1’ top = 0,065 [ 0,02
]
C-116

= 0,018
9366,52 1,221
FLV, bottom = 9366,52
√1207,14

= 0,031
Untuk tray spacing = 0,4 m dan FLV = 0,031 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 bottom:
σ bottom 0,2
K1’ bottom = K1 [ ] (Coulson, 1983) (C.84)
0,02
0,0000657 0,2
K1’ bottom = 0,06 [ ]
0,02

= 0,019

Gambar C.3. Flooding velocity, sieve plates


4. Menentukan Kecepatan Flooding
ρL - ρv
uf = K1’ √ (Coulson, 1983) (C.85)
ρv

Keterangan :
uf = Kecepatan flooding (m/s)
K1 = Konstanta
C-117

Kecepatan flooding bagian atas (top) :

kg kg )
(824,156 - 1,149
uf, top = 0,018 √ m3 m3
1,149 kg/m3

= 0,150 m/s
Kecepatan flooding bagian bawah (bottom) :

kg kg )
(1207,14 - 1,221
uf, bottom = 0,019 √ m3 m3
1,221 kg/m3

= 0,096
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding (Coulson,
1983) untuk perancangan diambil uv = 80% uf.
Kecepatan uap pada bagian atas (top) :
uv, top = 80% x uf top (C.86)
= 80% x 0,150 m/s
= 0,120 m/s
Kecepatan uap pada bagian bawah (bottom) :
uv, bottom = 80% x uf bottom (C.87)
= 80% x 0,096 m/s
= 0,076 m/s

5. Menentukan Laju Alir Volumetrik Maksimum


Vw
Qv = (C.88)
ρV

Keterangan :
Qv = Laju alir volumetrik maksimum (m3/s)
Vw = Laju alir massa uap (kg/s)
ρv = Densitas uap (m3/s)
Laju alir volumetrik maksimum bagian atas (top) :
9.366,52 kg/h
Qv, top =
1,149 kg/m3 x 3600 sec/h
C-118

= 0,226 m3/s
Laju alir volumetrik maksimum bagian bawah (bottom) :
9.366,52 kg/h
Qv, bottom =
1,221 kg/m3 x 3600 sec/h

= 0,212 m3/s

6. Menentukan Luas Area Netto Untuk Kontak Uap-Cair


Qv
An = (C.89)
uv
Keterangan :
An = Luas Area Netto (m2)
Qv = Laju alir volumetrik (m3/s)
uv = Kecepatan uap (m/s)

Luas area netto bagian atas (top) :


0,226 m3/s
An, top =
0,120 m/s

= 1,883 m2
Luas area netto bagian bawah (bottom) :
0,212 m3/s
An, bottom =
0,076 m/s

= 2,079 m2
7. Menentukan Luas Penampang Lintang Menara :
An
Ac = (C.90)
1-Ad
Luas penampang downcomer (Ad) = 20% dari luas keseluruhan, sehingga :
1,883 m2
Ac, top =
(1 – 0,2)

= 2,354 m2
2,079 m2
Ac, bottom =
(1 – 0,2)

= 2,559 m2
C-119

8. Menentukan Diameter Menara (Dc) Berdasarkan Kecepatan Flooding

4. Ac
Menghitung diameter menara : Dc =√
π

Diameter menara bagian atas (top)

4. 2,534 m2
Dc, top =√
3,14

= 1,731 m
Diameter menara bagian bawah (bottom)

4. 2,599 m2
Dc, bottom =√
3,14

= 1,819 m
9. Menentukan Jenis Aliran (Flow Pattern)
Kecepatan volumetris maksimum cairan :
Lw, B
QL.B = (C.91)
ρL,B
11.379,36 kg/jam
= kg x
1207,14 3600 sec/jam
m3

= 0,026 m3/s
Keterangan :
QL.bot = laju alir volumetrik bagian bottom (m3/s)
Lw = laju alir massa cairan bagian bottom (kg/s)
ρL = densitas cairan bagian bottom (kg/m3)
dari fig 11.28 (Coulson, 1983) untuk QL.B = 0,0026 m3/s maka jenis alirannya
adalah cross flow (single pass).
a. Perancangan Tray
Tray spacing = 0,4 m
Diameter menara, DC = 1,819 m
Luas menara, Ac = 2,984 m2
Luas Downcomer, Ad = 0,358 m2
Luas netto, An = 2,626 m2
Luas aktif, Aa = 2,268 m2
C-120

Luas hole, Ah = 0,068 m2


Dari figure 11.31 (Coulson,1983), untuk Ad/Ac = 0,12 maka:
Iw/Dc = 0,762
Panjang Weir, Iw = 0,762 x Dc
= 1,485 m

Gambar C.4 Grafik Penentuan Panjang Weir

Tinggi Weir (hw)


Untuk menara distilasi yang tekanan operasi di atas tekanan atmosfer, tinggi weir
yang digunakan antara 40-90 mm. Tinggi weir yang direkomendasikan adalah
antara 40 – 50 mm (Coulson,1983). Tinggi weir yang digunakan (hw) = 50 mm =
0,05 m
Diameter Hole (dh)
Diameter hole yang biasa yang digunakan adalah antara 2,5 – 12 mm, dan yang
direkomendasikan adalah 5 mm (Coulson, 1983). Diameter hole yang digunakan
adalah 5 mm.
Tebal Tray
Untuk bahan carbon steel tebal plate yang digunakan adalah 5 mm (3/16 in),
sedangkan untuk bahan stainless steel tebal plate yang digunakan adalah 3 mm.
C-121

Untuk menara distilasi ini digunakan bahan carbon steel, sehingga tebal plate yang
digunakan = 5 mm. (Coulson vol 6 1ed p465, 1983).

Pemeriksaan Weeping Rate


9.366,52 kg/jam
Lwmax = = 0,260 kg/s
3600 s/jam

turn-down ratio = 0,80


Kecepatan aliran cairan minimum:
Lw, min = 0,80 x 0,260 kg/s
= 0,208 kg/s
Tinggi weir liquid crest (how) :
Lw
how = 750( ) (C.92)
ρL x Iw

keterangan :
Lw = liquid flow rate, kg/s
Iw = weir length, m
ρL = densitas liquid, kg/m3
how = weir crest, mm liquid
1. Menara Bagian Atas
0,260 kg/s
how max = 750 ( )
1207,14 kg/m3 x 1,485 m

= 4,735 mm liquid
0,208 kg/s
how min = 750 ( )
1207,14 kg/m3 x 1,485 m

= 3,788 mm liquid
Pada minimum rate, (ho + how) = 54,735 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,4
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh = (C.93)
(ρv)1/2
C-122

Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,4 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,793 m/s
(1,149 kg/m3)1/2

Kecepatan uap minimum aktual (uam) :


Qv,t 0,226 m3/s
uam = = = 3,325 m/s
Ah 0,068 m2

2. Menara Bagian Bawah


0,260 kg/s
how max = 750 ( )
824,156 kg/m3 x 1,485 m

= 3,233 mm liquid
2,081 kg/s
how min = 750 ( )
824,156 kg/m3 x 1,485 m

= 2,586 mm liquid

Pada minimum rate, (ho + how) = 53,233 mm liquid


Dari fig. 11.30 Coulson, 1983 :
K2 = 30,5
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh =
(ρv)1/2

Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,5 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,544 m/s
(1,121 kg/m3)1/2

Kecepatan uap minimum aktual (uam) :


C-123

Qv,b 2,263 m3/s


uam = = = 3,129 m/s
Ah 0,068 m2

uam > Ŭh min sehingga tidak terjadi weeping.

Plate Pressure Drop


1. Menara Bagian Atas
Maksium vapour velocity through hole (Ŭh)
Qv,t
Ŭh = (C.94)
Ah
0,226 m3/s
= = 3,325 m/s
0,068 m2

Dari figure 11.34, untuk ketebalan plate/diameter lubang = 0,6


(Ah/Aa) x 100 = 10
Didapatkan nilai orifice coefficient (C0) = 0,74
Uh ρv
hd = 51 [ ]2 (C.95)
C0 ρL

hd = 1,436 mm liquid
Keterangan :
Uh = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Qv.bottom = Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = Densitas uap bagian bottom (kg/m3)
ρL = Densitas liquid bagian bottom (kg/m3)
C0 = Orifice coefficient
hd = Dry Plate drop (mm)
Residual Head
12,5 x 103
hr =
ρL

= 15,167 mm liquid
Keterangan :
hr = residual head (mm)
ρL = Densitas liquid bagian bottom (kg/m3)
C-124

Total Plate Pressure Drop


hT = hd + (hw + how) + hr (C.96)
= 71,339 mm liquid

Keterangan :
hr = residual head (mm)
hd = Dry Plate drop (mm)
hw = tinggi weir (mm)
how = tinggi weir liquid (mm cairan)
hT = total plate pressure drop (mm liquid)

∆Pt = 9,81 x 10-3 htρL


∆Pt = 576,774 Pa = 0,005692 atm
2. Menara Bagian Bawah
Uh = 3,129 m/s
hd = 0,922 mm liquid
hr = 10,355 mm liquid
ht = 64,511 mm liquid
∆Pt = 9,81 x 10-3 htρL
∆Pt = 763,942 Pa = 0,00754 atm
Downcomer Liquid Backup
1. Downcomer Liquid Backup
Pada saat menara distilasi dioperasikan, diharapkan tidak terjadi downcomer
liquid back-up. Besaran-besaran yang perlu dihitung untuk menentukan apakah
terjadi downcomer liquid back-up atau tidak adalah :
C-125

Gambar C.5 Gambar Cowncomer liquid back-up


Lw 2
hdc = 166 [ρ ] (C.97)
L Aap

hb = (how + hw) + ht + hdc (C.98)


keterangan : hap = tinggi ujung apron dari plate, mm
hw = tinggi weir, mm
Aap = luas permukaan clearance di bawah downcomer, m2
Lw = kecepatan massa cairan, kg/s
ρL = rapat massa cairan, kg/m3
hdc = head yang hilang di downcomer, mm liquid
hw = tinggi weir, mm liquid
how = tinggi cairan di atas weir, mm liquid
ht = plate pressure drop, mm liquid
1. Menara bagian atas
hap = 43 mm liquid
Aap = 0,063 m2
hdc = 3,820 mm liquid
hb = 129,894 mm liquid
hb = 0,129 m
1
(lt + hw) = 0,175 m
2
1
hb < 2 (lt + hw), maka pemilihan plate spacing 0,3 m sudah tepat
C-126

2. Menara bagian atas


hap = 43 mm liquid
Aap = 0,063 m2
hdc = 5,808 mm liquid
hb = 123,552 mm liquid
hb = 0,123 m
1
(lt + hw) = 0,175 m
2
1
hb < 2 (lt + hw), maka pemilihan plate spacing 0,3 m sudah tepat

Check Residence Time


Downcomer residence time perlu dihitung untuk menghindari terbawanya cairan
yang berisi udara melalui downcomer. Persamaan yang digunakan untuk
menghitung downcomer residence time adalah sebagai berikut :
Ad. hb. ρL
tr = (C.99)
Lw

Keterangan : tr = downcomer residence time, s


Ad = luas permukaan downcomer, m2
hb = clear liquid back-up, m
ρL = rapat massa cairan, kg/m3
Lw = kecepatan massa cairan, kg/s
Jika tr > 3 detik, maka tidak terjadi gelembung udara pada cairan yang masuk
melalui downcomer
Menara bagian atas
tr = 147,382 detik (<3 detik)
Menara bagian bawah
tr = 256,662 detik (<3 detik)
C-127

Check Entrainment
Actual Percentage Flooding For Design Area
Entrainment dihitung dari %flooding, dengan persamaan :
uv
%flooding = x 100% (C.100)
uf

Dengan: uv = kecepatan uap aktual, m/s


uf = kecepatan uap perancangan, m/s
Berdasarkan fig. 11.29, Coulson, 1986, dapat dilihat fractional entrainment, jika
Ψ<0,1, maka tidak terjadi entrainment.
1. Menara bagian atas
FLV = 0,037 m/s
%flooding = 80%
Dari fig. 11.29 diperoleh nilai Ψ 0,09 <0,1, maka tidak terjadi entrainment
2. Menara bagian bawah
FLV = 0,031 m/s
%flooding = 80%
Dari fig. 11.29 diperoleh nilai Ψ 0,08<0,1, maka tidak terjadi entrainment

Layout Tray
Digunakan cartridge-type construction dengan 50 mm unperforated strip around
tray edge dan 50 mm wide calming zones. Dari fig.11.32 (Coulson, 1983, hal.465),
untuk lw/Dc = 0,76, maka : θc = 102°
- Derajat tray edge
α = 180-θc
α =180 – 102 = 78°
- Panjang rata-rata unperforated edge strips
θ
Lm = (Dc - hw) x 3,14 (180) (C.101)
78
Lm = (1,95 - 0,05) x 3,14 ( )
180
Lm = 2,585 m
C-128

- Luas unperforated edge strip (Aup)


Aup = hw . Lm (C.102)
= 0,05 (2,5852)
= 0,129 m2
- Luas calming zone (Acz)
Acz = 2 x hw x (lw - (2 x hw) (C.103)
= 2 x 0,129 x (1,482 m) – 2 x 0,129)
= 0,138 m2
- Total area perforated (Ap)
Ap = Aa – (Aup + Acz) (C.104)
= 2,269 m2 – (0,129 m2 + 0,138 m2)
= 2,001 m2
Ah 0,068
=
Ap 2,001

Dari Fig. 11.33, hal 466, Coulson didapat nilai:


lp
= 2,5
dh
- Hole Pitch
lp
(lp) = x dh (C.105)
dh
= 2,5 x 5 mm
= 12,5 mm (0,0125 m)
- Jumlah Hole
Area untuk satu hole (Aoh)
dh2
Aoh = 3,14 (C.106)
4

0,05 2
Aoh = 3,14
4
Aoh = 19,625 mm2
Aoh = 1,9625 x 10-5 m2
Jumlah Lubang
Ah
= (C.107)
Aoh
C-129

0,068
=
1,9625 x 10−5 m2

= 3467 lubang
a. Spesifikasi Tray
Diameter menara, DC = 1,819 m
Diameter lubang, dh = 3 mm = 0,003 m
Hole pitch = 0,0125 m
Jumlah hole = 3467 lubang
Turn down ratio = 80%
Tray spacing = 0,4 m
Tray thickness = 0,003 m
Panjang weir = 1,4859 m
Tinggi weir = 0,05 m
Total pressure drop = 763,942706 pa
G. Mechanical Design
A. Head Menara
1. Menentukan Tebal Dinding dan Head Menara
OD

OA b=depth
icr of dish
A
sf B
ID
t

a
r

Gambar C.6 Skema Torispherical Head


Keterangan:
th = tebal head (in)
icr = inside corner radius (in)
r = radius of dish (in)
sf = straight flange (in)
C-130

OD = diameter luar (in)


ID = diameter dalam (in)
b = depth of dish (in)
OA = tinggi head (in)

2. Menentukan Tebal Shell


Material Stainless stell SA 240 (alasan pemilihan material: tahan terhadap
korosifitas dan memiliki struktur kuat).
Data perhitungan:
P = Tekanan Design = 3 atm = 44,088 psi
D = Diameter tangki = 1,819 m
ri = Jari-jari tangki = 0,975 m
S = Tekanan kerja yang diinginkan = 932,2297 atm
Cc = Korosi yang diinginkan = 0,02 m
Ej = Efisiensi pengelasan = 0,85
a =2
3 atm.0,975 m
tsilinder = + 0,02 m
2 (932,2297 atm)(0,85) - 0,6 x 3 atm

tsilinder = 0,024 m = 0,073 in


Digunakan tebal standar untuk shell: 3/16 in = 0,1875 in

3. Menentukan Tebal Head


OD = ID + (2 x ts) (C.108)
= 76,77 in + (2 x 3/16 in)
= 77,145 in
Dari Tabel 5.7 Brownell and Young:
Icr = 1,98 in
rc = 30 in

W
1
4 
3 r
icr  (C.109)
W = 1,723 in
C-131

44,088 psi (30 in) (1,723 in)


thead = + 0,7874 in
2 (13700 psi)(0,85)- 0,2 x 88,1757 psi

thead = 0,885 in

thead standar = 1,75 in maka tebal yang digunakan:


thead = 1,75 in

Untuk tebal head 1,75 in,dari tabel 5,8 Brownell and Young maka:
Sf = 1,5 – 4,5 in
Diambil sf = 3,5 in

ID 2
b = rc -√(rc -icr )2 - ( -icr ) (C.110)
2

76,77 in 2
b = 30 in -√(30 in-1,98 in)2 - ( -1,98 in)
2

b = 51 in
= 1,3 m

4. Tinggi Head (OA)


Dari Tabel 5.8 Brownell and Young, untuk ketebalan head = 1,75 in, sf = 1,5 -
4,5 in, dan dipilih sf = 3,5 in.
OA = th + b + sf (C.111)
= 1,75 + 51 + 3,5
= 56,25 in
= 1,43 m
AB = ri - icr (C.112)
= 38,39 in – 1,98 in
= 36,41 in
= 0,925 m
BC = rc - icr (C,113)
= 30 in – 1,98 in
C-132

= 28,02 in
= 0,712 m

AC = √AB2 -BC2 (C.114)

=√36,412 -28,022

= 23,250 in
= 0,59 m

5. Tinggi Menara
Data perhitungan:
Diameter kolom, Dc = 1,819 m
Luas kolom, Ac = 2,985 m2
Volume head = 0,000049 (D3)
= 0,000049 (1,95)3
= 0,0003633 m3
π
Volume head pada sf = x ID2 x sf (C.115)
4

= 3,14/4 x (76,77 in)2 x 3,5


= 16192,76 in3
= 0,2654 m3
Volume total Head = Vhead tanpa sf + Vhead pada sf (C.116)
= 0,0003633 m3 + 0,2654 m3
= 0,2657 m3
Blank diameter = OD + OD/24 + 2sf +2/3.icr (C.117)
= 77,145 in + 77,145 in/24 + 2 (3,5 in) + 2/3 (1,98)
= 88,679 in
Untuk bagian bottom kolom:
L
Q = ρL (C.118)
11379.36
Q =
1014
Q = 11,222 m3/jam
Q = 0,187 m3/menit
C-133

Waktu tinggal dibawah plate terakhir: 5 – 10 menit (Ulrich,1984). Waktu


tinggal cairan dipilih = 5 menit.
Vcairan = Q x waktu tinggal (C.119)
= 0,187 m3/menit x 5 menit
= 0,935 m3
Tinggi cairan dalam shell (HL):
π
Vcairan = 4 Dc2 HL (C.120)

HL = 4,53 m

6. Tinggi Total Menara


Jarak dari plate teratas =1m
Tinggi penyangga menara =1m
Jumlah plate = 12 buah
Tebal plate = 0,003 m
Tinggi head + tebal head = OA – sf (C.121)
= 1,43 m – 0,089 m = 1,341 m
Tinggi plate terbawah = HL + (OA –sf) (C.122)
= 1,403 m
Tinggi total = 1 + (14 x 0,3) + 0,005 + 1,341 + 1,403
= 7,013 m
= 313,976 in

H. Menentukan Perpipaan dan Nozzle Produk dan Umpan


a. Pipa Feed
Diketahui:
G = 20.745,88 kg/jam = 5,762 g/s
μ = 0,441 cp = 4,441 x 10-4 Pa.s
ρ = 984,376 kg/m3
G
Debit Aliran (Q) = (C.123)
ρ
C-134

20.745,88 kg/jam
=
984,376 kg/m3

= 21,075 m3/jam
= 5,85 x 10-3 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37 (C.124)
= 352,8 x 5,7200,52 x (0,441 x 10-3)0,03 x 984 30,37
= 54,314 mm
= 3,277 in

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 3 in
Schedule Member = 40 (standar)
ID = 3,068 in = 0,077 m
OD = 3,5 in
A’ = 7,38 in2 = 0,804 ft2
Kecepatan Aliran Feed (V) = 1,229 m/s
Nre = 213873,0579
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 3 in
OD of pipe = 3,5 in

b. Pipa Gas Keluar dari Puncak Menara


Diketahui:
G = 9.366,52 kg/jam = 2,602 g/s
π = 0,257 cp = 2,57 x 10-4 Pa.s
ρ = 822,667 kg/m3
G
Debit Aliran (Q) =
ρ
C-135

9.366,52 kg/jam
=
822,667 kg/m3

= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,023 m/s
Nre = 205444,4092
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

c. Pipa Cairan Refluks di Puncak Menara


Diketahui:
G = 9.366,52 kg/jam = 2,602 g/s
π = 0,257 cp = 2,57 x 10-4 Pa.s
ρ = 822,667 kg/m3
G
Debit Aliran (Q) =
ρ
C-136

9.366,52 kg/jam
=
822,667 kg/m3

= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,023 m/s
Nre = 205444,4092
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

d. Pipa Cairan Keluar dari Dasar Menara


Diketahui:
G = 11.379,36 kg/jam = 3,160 g/s
π = 0,301 cp = 3,01 x 10-4 Pa.s
ρ = 1205,59 kg/m3
G
Debit Aliran (Q) =
ρ
C-137

11.379,36 kg/jam
=
1205,59 kg/m3

= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,213 m/s
Nre = 11996565,94
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

e. Pipa Vapor Keluaran Reboiler


Diketahui:
G = 11.379,36 kg/jam = 3,160 g/s
π = 0,301 cp = 3,01 x 10-4 Pa.s
ρ = 1205,59 kg/m3
G
Debit Aliran (Q) =
ρ
C-138

11.379,36 kg/jam
=
1205,59 kg/m3

= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,213 m/s
Nre = 11996565,94
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

I. Design Manhole Acces (Shell Manhole)


Manhole merupakan lubang pemeriksaan yang diperlukan pada saat
pembersihan atau pemeriksaan pada bagian dalam kolom. Setiap pressure vessel
yang dalam operasinya melibatkan liquid ataupun vessel yang ada didalamnya
terdapat alat lain seperti impeler, packing, plate dan lainnya sebaiknya dilengkapi
dengan manhole yang tujuannya untuk pemeriksaan dan perbaikan. Untuk vessel
C-139

dengan diameter antara 48 in sampai 96 in, digunakan manhole dengan diameter


dalam minimal 15 in. (Megyesy, 1983). Manhole dipasang dengan tujuan sebagai
tempat untuk perbaikan plate.

Gambar C.7 Detail Design Manhole

Direncanakan manhole dipasang pada bagian samping sisi kolom sebanyak 2 buah
dengan ukuran standar 20 in berdasarkan rekomendasi API standar 12 C. Maka
konstruksi manhole berdasarkan rekomendasi API standar 12 C (Brownell and
Young, appendix F item 3 dan 4) dengan spesifikasi:
Diameter Manhole (ID) = 20 in
Ketebalan cover plate = 5/8 in
Bolting-flange thickness after finishing = ½ in
Dimensi manhole 20 in berdasarkan rekomendasi API Standard 12 C:
Ketebalan shell manhole = 0,3125 in
Ukuran Fillet Weld A = 0,1875 in
Ukuran Fillet Weld B = 0,3125 in
Approx Radius ® = 5/8 in
Length of Side (L) = 45 in
Width of Renforcing Plate (W) = 54 in
Max Diameter of Hole in Shell = 24,5 in
Inside Diameter of Manhole = 20 in
Diameter Bolt Circle (DB) = 26,25 in
Diameter of Cover Plate (DC) = 28,75 in
C-140

C.20 Menara Distilasi (D-02)


Fungsi : Memisahkan Metanol dari Campuran Metil Formiat
Tipe : Sieve Tray Tower

Input CD-02

RB-02
Gambar C.8 Menara Distilasi D-02

Perhitungan ini dilakukan untuk mengetahui spesifikasi Menara Distilasi


(D-02), yang meliputi:
1. Kondisi operasi
2. Spesifikasi shell (diameter, tinggi dan tebal) dan head menara
3. Spesifikasi tray
4. Cek kondisi aliran (flooding dan weeping)
5. Isolasi (ketebalan)
6. Spesifikasi alat penunjang menara distilasi

B. Penentuan Tipe Kolom Distilasi


Dalam perancangan menara distilasi ini dipilih jenis Tray dengan
pertimbangan diameter kolom lebih dari 3 ft (0,91 m) (Walas, 1990). Sedangkan
jenis tray yang digunakan adalah sieve tray dengan pertimbangan:
1. Pressure drop rendah dan efesiensi tinggi (tab. 9.22, ludwig, 1980).
2. Lebih ringan, murah karena pembuatannya lebih mudah.
3. Biaya perawatan murah karena mudah dibersihkan.
C-141

C. Penentuan Bahan Konstuksi


Dipilih bahan konstruksi jenis Stainless SA 240 Grade B, dengan
pertimbangan:
1. Mempunyai allowable stress yang besar
2. Struktur kuat
3. Tahan terhadap korosifitas tinggi

D. Kondisi Operasi
Langkah-langkah perhitungannya adalah sebagai berikut:
1. Menentukan kondisi operasi atas dan bawah menara distilasi
2. Menentukan volatilitas rata-rata
3. Mengecek pemilihan light key component (LK) dan heavy key component
(HK) dengan persamaan Shira’s et. Al. pada Rm
KLK
α= (Coulson, 1983)
KHK
αtop +αbottom
αAvg = (Coulson, 1983)
2

4. Menghitung jumlah plate minimum dengan persamaan Fenske (R. Van


Wingkle;eg : 5.118 ; p 236)
Log[(XLK /XHK )D x (XHK /XLK )B ]
Nm= (Coulson, 1983)
Log(αlk )

5. Mencari Refluks ratio minimum dengan persamaan Colburn & Underwood


1 Xd LK α(1-Xd LK)
RM = [ - ] (Coulson, 1983)
α-1 XF LK (1-XF LK)

6. Menentukan lokasi feed plate dengan persamaan Kirkbride


m B X (X ) 2
Log =0,206 Log { ( HK ) [(X LK )B ] } (Coulson, 1983)
p D X LK F HK D
C-142

2. Menentukan kondisi operasi atas dan bawah menara distilasi


Tabel C.17 Neraca Massa D-01

Neraca Neraca massa keluar


Fraksi (Xi)
Komponen massa masuk (kg/jam)
(kg/jam) Top Bottom Top Bottom

HCOOCH3 1604,90 1495,56 109,34 0,94 0,01


H2O 4,44 0,00 4,44 0,00 0,00
HCOOH 7,06 0,00 7,06 0,00 0,00
CH3OH 7750,12 51,09 7699,04 0,06 0,99

1546,65 7819,87
Total 9366,52 1,00 1,00
9366,52

Tekanan uap tiap komponen dihitung dengan menggunakan persamaan:


C2
P°=exp [C1 + +C3 ln T+C4 x TC5 ]
T

Keterangan:
A, B, C, D, E = konstanta
P = tekanan uap komponen (pa)
T = tekanan (K)
Konstanta untuk tiap-tiap komponen dapat dilihat pada tabel berikut:
Tabel C.18 Konstanta Tekanan Uap
Komponen A B C D E
HCOOCH3 77,184 -5606,01 -8,392 7,85x10-6 2
H2O 73,649 -7258,2 -7,3037 4,17 x10-6 2
HCOOH 50,323 -5378,2 -4,203 3,47 x10-6 2
CH3OH 81,77 -6878 -8,7078 7,19 x10-6 2
Sumber: (Carl L. Yaws,2005)
C-143

Tabel C.19 Hasil Perhitungan Kondisi Umpan Kolom Distilasi (D-02)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)

HCOOCH3 19,82 26,73 0,10 1,348830123 0,134006969


H2O 1,07 0,25 0,00 0,072897523 6,67 x 10-5
HCOOH 1,64 0,15 0,00 0,111842624 6,37 x 10-5
CH3OH 5,10 241,87 0,90 0,347275591 0,31225759

Total 269,00 1,00 0,446395067

Tabel C.20 Hasil Perhitungan Top Produk Kolom Distilasi (D-02)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)

HCOOCH3 111,87 24,90 0,94 7,612342363 7,154334317


H2O 14,69 0,00 0,00 0,999363794 5,17 x 10-8
HCOOH 14,36 0,00 0,00 0,977243806 2,50 x 10-9
CH3OH 50,97 1,59 0,06 3,468520195 2,09 x 10-1

Total 26,50 1,00 7,36

Tabel C.21 Hasil Perhitungan Bottom Produk Kolom Distilasi (D-02)


Komponen Tekanan Laju alir Fraksi mol Kesetimbangan Fraksi mol
(Pi) (kmol) (Xi) (Ki) (Yi = xi.ki)

HCOOCH3 0,00 1,82 0,01 9,869 x 10-6 7,409 x 10-8


H2O 0,68 0,25 0,00 0,046245374 7,698 x 10-5
HCOOH 1,13 0,15 0,00 0,077132138 4,876 x 10-5
C-144

CH3OH 3,42 240,28 0,99 0,232789301 0,230657838

Total 242,50 1,00 0,230753659

A. Relatif Volatilitas Rata-Rata


Komponen kunci
Light Key = Metil Formiat
Heavy Key = Asam Formiat
KLK
α = (Eq 8.13 Ludwig, 1980)
KHK

αD = 1,871
αB = 1,577
αtop +αbottom
αAvg = (Eq 8.11 Ludwig, 1980)
2
1,871 + 1,577
αAvg =
2
αAvg = 1,724
B. Menentukan stage minimum
Dengan menggunakan metode Fenske
Log[(XLK /XHK )D x (XHK /XLK )B ]
NM =
Log(αAvg )

NM = 4,794
C. Mencari Refluks ratio minimum
1 Xd LK α(1-Xd LK)
RM = [ - ]
α-1 XF LK (1-XF LK)

RM = 0,809
R operasi berkisar antara 1,2 – 1,5 Rm (Geankoplis, 1993)
Diambil Roperasi = 1,2 x Rm
= 1,2 x 0,809
= 0,9708
C-145

D. Penentuan Jumlah Stage


ROP
= 0,536
Rm +1

Rm
= 0,447
Rm +1

Gambar C.9 Grafik Penentuan Stage Ideal


Untuk menentukan jumlah plate teoritis digunakan korelasi Gilliland
sehingga didapat nilai R = 0,44.
Nm
= 0,4
N

Nm = 4,794
4,794
N = 0,4

N = 11
N actual = 11 + 1 (stage reboiler)
= 12
C-146

E. Feed Location
Feed location ditentukan dengan menggunakan metode Kirkbride.
m B X (X ) 2
Log p = 0,206 Log {D ( XHK ) [(X LK )B ] } (vol.6 Eq 11.62 Coulson,1983)
LK F HK D

m
Log = 0,9
p
m
=9
p
m=9p
N = m+p
11 = 9 p+p
p =1
m = N-p
=11-1 =10

F. Menentukan Spesifikasi Menara Distilasi


1. Menentukan Sifat-sifat Fisika
Densitas pada suhu atas (304,87 K)
Tabel C.22 Hasil Perhitungan Densitas Liquid
Komponen BM Distilat yD, D ρ Liquid yD/ρi
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 1495,56 0,94 975 9,64 x 10-4
H2O 18,02 0,00 0,00 994,1 5,21 x 10-11
HCOOH 46,03 0,00 0,00 1226,47 2,09 x 10-12
CH3OH 32,04 51,09 0,06 810 7,43 x 10-5

Total 1546,65 1,00 1,04 x 10-3


⅀yD
ρliquid = yD

ρi

= 963,194 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
C-147

R = 8.314,34 Pa/kmol.K
ρuap = (BM x P) /RT

Tabel C.23 Hasil Perhitungan Densitas Uap


Komponen BM Distilat yD, D ρ Uap yD/ρi
(kg/kmol) (Kg/Jam) (kg/m3)

HCOOCH3 60,05 1495,56 0,94 2,400 0,391


H2O 18,02 0,00 0,00 0,720 7,187 x 10-8
HCOOH 46,03 0,00 0,00 1,839 1,393 x 10-9
CH3OH 32,04 51,09 0,06 1,280 0,046

Total 1546,65 1,00 0,438


⅀yD
ρuap = yD

ρi

= 2,280 kg/m3

Densitas pada suhu bawah (336,06 K)


Tabel C.24 Hasil Perhitungan Densitas Liquid
Komponen BM Bottom xB, B ρ Liquid xB/ρi
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 109,34 0,01 975 7,70 x 10-6
H2O 18,02 4,44 0,00 994,1 1,02 x 10-6
HCOOH 46,03 7,06 0,00 1226,47 5,15 x 10-7
CH3OH 32,04 7699,04 0,99 810 1,22 x 10-3

Total 7819,87 1,00 1,23 x 10-3


⅀xB
ρliquid = xB

ρi

= 811,36 kg/m3
Densitas uap
P = 1 atm = 101325 Pa
R = 8.314,34 Pa/kmol.K
C-148

ρ uap = (BM x P) /RT

Tabel C.25 Hasil Perhitungan Densitas Uap


Komponen BM Bottom xB, B ρ Uap xB/ρ
(kg/kmol) (Kg/Jam) (kg/m3)
HCOOCH3 60,05 109,34 0,01 2,177 3,45 x 10-3
H2O 18,02 4,44 0,00 0,653 1,55 x 10-3
HCOOH 46,03 7,06 0,00 1,669 3,79 x 10-4
CH3OH 32,04 7699,04 0,99 1,161 0,852

Total 7819,87 1,00 0,858

⅀xB
ρuap = xB

ρi

= 1,165 kg/m3
2. Menghitung Tegangan Permukaan
Tegangan permukaan dihitung dengan persamaan Sudgen:
Pch (𝜌𝐿−𝜌𝑣) 4
σ=[ ] x 10-12 (Coulson, 1983)
𝑀

Keterangan :
σ = Tegangan permukaan (dyne/cm)
Pch = Sudgen’s parachor
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
M = Berat molekul (kg/kmol)
Tabel C.26 Data untuk menentukan Pch (Coulson, 1983)
Atom, group or bond Contribution Atom, group or bond Contribution
C 4,8 Si 25,0
H 17,1 Al 38,6
H in (OH) 11,3 Sn 57,9
O 20,0 As 50,1
O2 60,0 Double bond:terminal
C-149

N 12,5 2,3position 23,2


S 48,2 3,4 position
P 37,7 Triple bond 46,6
F 25,7 Rings
Cl 54,3 3-membered 16,7
Br 68,0 4-membered 11,6
I 91,0 5-membered 8,5
Se 62,5 6-membered 6,1

Tabel C.27 Perhitungan σ top


Komponen BM yD, D Pch Σ yD x σ
(kg/kmol)
HCOOCH3 60,05 0,94 113,2 10,766 8,73 x 10-2
H2O 18,02 0,00 54,2 69,777 7,42 x 10-10
HCOOH 46,03 0,00 74,2 5,756 4,45 x 10-10
CH3OH 32,04 0,06 93,2 61,042 9,86 x 10-4

Total 1,00 8,83 x 10-2


σ mix top = 0,08827 dyne/cm = 0,00008 N/m

Tabel C.28 Perhitungan σ bottom


Komponen BM yD, D Pch Σ yD x σ
(kg/kmol)
HCOOCH3 60,05 0,01 113,2 5,441 1,38 x 10-3
H2O 18,02 0,00 54,2 35,263 2,88 x 10-5
HCOOH 46,03 0,00 74,2 2,909 2,17 x 10-4
CH3OH 32,04 0,99 93,2 30,849 3,21 x 10-2

Total 1,00 3,37 x 10-2


σ mix bottom = 0,03374 dyne/cm = 0,00003 N/m
C-150

3. Menentukan Diameter Menara


Tinggi plate spacing pada umumnya antara 0,3-0,6 m (Coulson, 1983).
Diambil tray spacing = 0,3 m
Laju alir massa bagian atas
F = 9366,52 kg/jam
D = 1546,65 kg/jam
L = 1546,65 kg/jam
V = 1546,65 kg/jam
Laju alir massa bagian bawah
B = 7819,87 kg/jam
L* = 7819,87 kg/jam
V* = 7819,87 kg/jam
Liquid-vapor flow factor
Lw ρL
FLV = V √ρ (Coulson, 1983)
w v

Keterangan :
FLV = Liquid-vapor flow factor
LW = Laju alir massa cairan (Kg/h)
VW = Laju alir massa uap (kg/h)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
1546,65 2,280
FLV, top = 1546,65
√963,194

= 0,048
Untuk tray spacing = 0,3 m dan FLV = 0,048 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 top:
σ top
K1’ top = K1 [ 0,02 ]0,2 (Coulson, 1983)
0,00008 0,2
K1’ top = 0,065 [ ]
0,02

= 0,021
1546,65 1,165
FLV, bottom = 1546,65
√811,36
C-151

= 0,037
Untuk tray spacing = 0,3 m dan FLV = 0,037 maka K1 = 0,065 (Coulson, 1983)
Koreksi nilai K1 bottom:
σ bottom 0,2
K1’ bottom = K1 [ ] (Coulson, 1983)
0,02
0,00003 0,2
K1’ bottom = 0,06 [ ]
0,02

= 0,016

Gambar C.10. Flooding velocity, sieve plates


10. Menentukan Kecepatan Flooding
ρL - ρv
uf = K1’ √ (Coulson, 1983)
ρv

Keterangan :
uf = Kecepatan flooding (m/s)
K1 = Konstanta
C-152

Kecepatan flooding bagian atas (top) :

kg kg )
(963,194 – 2,280
uf, top = 0,021 √ m3 m3
2,280 kg/m3

= 0,150 m/s

Kecepatan flooding bagian bawah (bottom) :

kg kg )
(811,36 - 1,165
uf, bottom = 0,016 √ m3 m3
1,165 kg/m3

= 0,096
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding (Coulson, 1983)
untuk perancangan diambil uv = 80% uf.
Kecepatan uap pada bagian atas (top) :
uv, top = 80% x uf top

= 80% x 0,150 m/s


= 0,120 m/s
Kecepatan uap pada bagian bawah (bottom) :
uv, bottom = 80% x uf bottom

= 80% x 0,096 m/s


= 0,076 m/s

11. Menentukan Laju Alir Volumetrik Maksimum


Vw
Qv = ρV

Keterangan :
Qv = Laju alir volumetrik maksimum (m3/s)
Vw = Laju alir massa uap (kg/s)
ρv = Densitas uap (m3/s)
Laju alir volumetrik maksimum bagian atas (top) :
1546,65 kg/h
Qv, top = 2,280 kg/m3 x 3600 sec/h

= 0,114 m3/s
C-153

Laju alir volumetrik maksimum bagian bawah (bottom) :


1546,65 kg/h
Qv, bottom = 1,165 kg/m3 x 3600 sec/h

= 0,223 m3/s
12. Menentukan Luas Area Netto Untuk Kontak Uap-Cair
Qv
An = uv

Keterangan :
An = Luas Area Netto (m2)
Qv = Laju alir volumetrik (m3/s)
uv = Kecepatan uap (m/s)

Luas area netto bagian atas (top) :


0,114 m3/s
An, top = 0,120 m/s

= 1,949 m2
Luas area netto bagian bawah (bottom) :
0,223 m3/s
An, bottom = 0,076 m/s

= 2,079 m2
13. Menentukan Luas Penampang Lintang Menara :
An
Ac = 1-A
d

Luas penampang downcomer (Ad) = 20% dari luas keseluruhan, sehingga :


1,949 m2
Ac, top = (1 – 0,2)

= 2,436 m2
2,079 m2
Ac, bottom = (1 – 0,2)

= 2,599 m2

14. Menentukan Diameter Menara (Dc) Berdasarkan Kecepatan Flooding

4. Ac
Menghitung diameter menara : Dc =√
π
C-154

Diameter menara bagian atas (top)

4. 2,436 m2
Dc, top =√
3,14

= 1,861 m
Diameter menara bagian bawah (bottom)

4. 2,599 m2
Dc, bottom =√
3,14

= 1,95 m
15. Menentukan Jenis Aliran (Flow Pattern)
Kecepatan volumetris maksimum cairan :
Lw, B
QL.B =
ρL,B
7819,87 kg/jam
= kg x
811,36 3600 sec/jam
m3

= 0,003 m3/s
Keterangan :
QL.bot = laju alir volumetrik bagian bottom (m3/s)
Lw = laju alir massa cairan bagian bottom (kg/s)
ρL = densitas cairan bagian bottom (kg/m3)
dari fig 11.28 (Coulson, 1983) untuk QL.B = 0,0026 m3/s maka jenis alirannya
adalah cross flow (single pass).
b. Perancangan Tray
Tray spacing = 0,3 m
Diameter menara, DC = 1,95 m
Luas menara, Ac = 2,984 m2
Luas Downcomer, Ad = 0,358 m2
Luas netto, An = 2,626 m2
Luas aktif, Aa = 2,268 m2
Luas hole, Ah = 0,068 m2
Dari figure 11.31 (Coulson,1983), untuk Ad/Ac = 0,12 maka:
C-155

Iw/Dc = 0,762
Panjang Weir, Iw = 0,762 x Dc
= 1,485 m

Gambar C.11 Grafik Penentuan Panjang Weir

Tinggi Weir (hw)


Untuk menara distilasi yang tekanan operasi di atas tekanan atmosfer, tinggi weir
yang digunakan antara 40-90 mm. Tinggi weir yang direkomendasikan adalah
antara 40 – 50 mm (Coulson,1983). Tinggi weir yang digunakan (hw) = 50 mm =
0,05 m

Diameter Hole (dh)


Diameter hole yang biasa yang digunakan adalah antara 2,5 – 12 mm, dan yang
direkomendasikan adalah 5 mm (Coulson, 1983). Diameter hole yang digunakan
adalah 5 mm.

Tebal Tray
Untuk bahan carbon steel tebal plate yang digunakan adalah 5 mm (3/16 in),
sedangkan untuk bahan stainless steel tebal plate yang digunakan adalah 3 mm.
C-156

Untuk menara distilasi ini digunakan bahan carbon steel, sehingga tebal plate yang
digunakan = 5 mm. (Coulson vol 6 1ed p465, 1983).
Pemeriksaan Weeping Rate
9.366,52 kg/jam
Lwmax = = 0,260 kg/s
3600 s/jam

turn-down ratio = 0,80


Kecepatan aliran cairan minimum:
Lw, min = 0,80 x 0,260 kg/s
= 0,208 kg/s
Tinggi weir liquid crest (how) :
Lw
how = 750(ρ )
L x Iw

keterangan :
Lw = liquid flow rate, kg/s
Iw = weir length, m
ρL = densitas liquid, kg/m3
how = weir crest, mm liquid
3. Menara Bagian Atas
0,260 kg/s
how max = 750 ( )
1207,14 kg/m3 x 1,485 m

= 4,051 mm liquid
0,208 kg/s
how min = 750 ( )
1207,14 kg/m3 x 1,485 m

= 3,848 mm liquid
Pada minimum rate, (ho + how) = 54,051 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,4
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh =
(ρv)1/2

Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
C-157

dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,4 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,793 m/s
(1,149 kg/m3)1/2

Kecepatan uap minimum aktual (uam) :


Qv,t 0,226 m3/s
uam = = = 3,325 m/s
Ah 0,068 m2

4. Menara Bagian Bawah


0,260 kg/s
how max = 750 ( )
824,156 kg/m3 x 1,485 m

= 3,233 mm liquid
2,081 kg/s
how min = 750 ( )
824,156 kg/m3 x 1,485 m

= 2,586 mm liquid
Pada minimum rate, (ho + how) = 53,233 mm liquid
Dari fig. 11.30 Coulson, 1983 :
K2 = 30,5
Kecepatan uap minimum desain dihitung dengan persamaan Eduljee:
[K2 - 0,90 (25,4 - dh)]
Ŭh =
(ρv)1/2

Keterangan:
ŭh = kecepatan uap minimum desain, m/s
K2 = konstanta
dh = diameter hole, mm
ρv = densitas uap, kg/m3
[30,5 - 0,90 (25,4 – 5 mm)]
Ŭh = = 1,544 m/s
(1,121 kg/m3)1/2

Kecepatan uap minimum aktual (uam) :


Qv,b 2,263 m3/s
uam = = = 3,129 m/s
Ah 0,068 m2

uam > Ŭh min sehingga tidak terjadi weeping.


C-158

Plate Pressure Drop


3. Menara Bagian Atas
Maksium vapour velocity through hole (Ŭh)
Qv,t
Ŭh =
Ah
0,226 m3/s
= = 3,325 m/s
0,068 m2

Dari figure 11.34, untuk ketebalan plate/diameter lubang = 0,6


(Ah/Aa) x 100 = 10
Didapatkan nilai orifice coefficient (C0) = 0,74
Uh ρv
hd = 51 [ ]2
C0 ρL

hd = 1,436 mm liquid
Keterangan :
Uh = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Qv.bottom = Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = Densitas uap bagian bottom (kg/m3)
ρL = Densitas liquid bagian bottom (kg/m3)
C0 = Orifice coefficient
hd = Dry Plate drop (mm)
Residual Head
12,5 x 103
hr = ρL

= 12,977 mm liquid
Keterangan :
hr = residual head (mm)
ρL = Densitas liquid bagian bottom (kg/m3)
Total Plate Pressure Drop
hT = hd + (hw + how) + hr
= 67,649 mm liquid
Keterangan :
hr = residual head (mm)
C-159

hd = Dry Plate drop (mm)


hw = tinggi weir (mm)
how = tinggi weir liquid (mm cairan)
hT = total plate pressure drop (mm liquid)
∆Pt = 9,81 x 10-3 htρL
∆Pt = 639,213 Pa = 0,006308 atm
4. Menara Bagian Bawah
Uh = 3,129 m/s
hd = 1,436 mm liquid
hr = 15,406 mm liquid
ht = 71,656 mm liquid
∆Pt = 9,81 x 10-3 htρL
∆Pt = 570,340 Pa = 0,005628 atm
Downcomer Liquid Backup
2. Downcomer Liquid Backup
Pada saat menara distilasi dioperasikan, diharapkan tidak terjadi downcomer
liquid back-up. Besaran-besaran yang perlu dihitung untuk menentukan apakah
terjadi downcomer liquid back-up atau tidak adalah :

Gambar C.12 Gambar Cowncomer liquid back-up


C-160

Lw
hdc = 166 [ρ ]2
L Aap

hb = (how + hw) + ht + hdc


keterangan : hap = tinggi ujung apron dari plate, mm
hw = tinggi weir, mm
Aap = luas permukaan clearance di bawah downcomer, m2
Lw = kecepatan massa cairan, kg/s
ρL = rapat massa cairan, kg/m3
hdc = head yang hilang di downcomer, mm liquid
hw = tinggi weir, mm liquid
how = tinggi cairan di atas weir, mm liquid
ht = plate pressure drop, mm liquid
3. Menara bagian atas
hap = 43 mm liquid
Aap = 0,063 m2
hdc = 3,820 mm liquid
hb = 125,521 mm liquid
hb = 0,125 m
1
(lt + hw) = 0,175 m
2
1
hb < 2 (lt + hw), maka pemilihan plate spacing 0,3 m sudah tepat

4. Menara bagian atas


hap = 43 mm liquid
Aap = 0,063 m2
hdc = 5,808 mm liquid
hb = 132,274 mm liquid
hb = 0,132 m
1
(lt + hw) = 0,175 m
2
1
hb < 2 (lt + hw), maka pemilihan plate spacing 0,3 m sudah tepat
C-161

Check Residence Time


Downcomer residence time perlu dihitung untuk menghindari terbawanya cairan
yang berisi udara melalui downcomer. Persamaan yang digunakan untuk
menghitung downcomer residence time adalah sebagai berikut :
Ad. hb. ρL
tr = Lw

Keterangan : tr = downcomer residence time, s


Ad = luas permukaan downcomer, m2
hb = clear liquid back-up, m
ρL = rapat massa cairan, kg/m3
Lw = kecepatan massa cairan, kg/s
Jika tr > 3 detik, maka tidak terjadi gelembung udara pada cairan yang masuk
melalui downcomer
Menara bagian atas
tr = 166,446 detik (<3 detik)
Menara bagian bawah
tr = 184,689 detik (<3 detik)

Check Entrainment
Actual Percentage Flooding For Design Area
Entrainment dihitung dari %flooding, dengan persamaan :
uv
%flooding = u x 100%
f

Dengan: uv = kecepatan uap aktual, m/s


uf = kecepatan uap perancangan, m/s
Berdasarkan fig. 11.29, Coulson, 1986, dapat dilihat fractional entrainment, jika
Ψ<0,1, maka tidak terjadi entrainment.
3. Menara bagian atas
FLV = 0,048 m/s
%flooding = 80%
Dari fig. 11.29 diperoleh nilai Ψ 0,09 <0,1, maka tidak terjadi entrainment
C-162

4. Menara bagian bawah


FLV = 0,037 m/s
%flooding = 80%
Dari fig. 11.29 diperoleh nilai Ψ 0,08<0,1, maka tidak terjadi entrainment

Layout Tray
Digunakan cartridge-type construction dengan 50 mm unperforated strip around
tray edge dan 50 mm wide calming zones. Dari fig.11.32 (Coulson, 1983, hal.465),
untuk lw/Dc = 0,76, maka : θc = 102°
- Derajat tray edge
α = 180-θc
α =180 – 102 = 78°
- Panjang rata-rata unperforated edge strips
θ
Lm = (Dc - hw) x 3,14 ( )
180
78
Lm = (1,95 - 0,05) x 3,14 ( )
180
Lm = 2,585 m
- Luas unperforated edge strip (Aup)
Aup = hw . Lm
= 0,05 (2,5852)
= 0,129 m2
- Luas calming zone (Acz)
Acz = 2 x hw x (lw - (2 x hw)
= 2 x 0,129 x (1,482 m) – 2 x 0,129)
= 0,138 m2
- Total area perforated (Ap)
Ap = Aa – (Aup + Acz)
= 2,269 m2 – (0,129 m2 + 0,138 m2)
= 2,001 m2
Ah 0,068
=
Ap 2,001
C-163

Dari Fig. 11.33, hal 466, Coulson didapat nilai:


lp
= 2,5
dh
- Hole Pitch
lp
(lp) = x dhHN
dh
= 2,5 x 5 mm
= 12,5 mm (0,0125 m)
- Jumlah Hole
Area untuk satu hole (Aoh)
dh2
Aoh = 3,14 4

0,05 2
Aoh = 3,14 4

Aoh = 19,625 mm2


Aoh = 1,9625 x 10-5 m2
Jumlah Lubang
Ah
= Aoh
0,068
=
1,9625 x 10-5 m2

= 3467 lubang

b. Spesifikasi Tray
Diameter menara, DC = 1,95 m
Diameter lubang, dh = 5 mm = 0,005 m
Hole pitch = 0,0125 m
Jumlah hole = 3467 lubang
Turn down ratio = 80%
Tray spacing = 0,3 m
Tray thickness = 0,003 m
Panjang weir = 1,4859 m
Tinggi weir = 0,05 m
C-164

Total pressure drop = 763,942706 pa

G. Mechanical Design
A. Head Menara
1. Menentukan Tebal Dinding dan Head Menara
OD

OA b=depth
icr of dish
A
sf B
ID
t

a
r

Gambar C.13 Skema Torispherical Head

Keterangan:
th = tebal head (in)
icr = inside corner radius (in)
r = radius of dish (in)
sf = straight flange (in)
OD = diameter luar (in)
ID = diameter dalam (in)
b = depth of dish (in)
OA = tinggi head (in)

2. Menentukan Tebal Shell


Material Carbon Steel CS 300 (alasan pemilihan material: tahan terhadap
korosifitas dan memiliki struktur kuat).
Data perhitungan:
P = Tekanan Design = 3 atm = 44,088 psi
C-165

D = Diameter tangki = 1,95 m


ri = Jari-jari tangki = 0,975 m
S = Tekanan kerja yang diinginkan = 932,2297 atm
Cc = Korosi yang diinginkan = 0,02 m
Ej = Efisiensi pengelasan = 0,85
a =2

3 atm.0,975 m
tsilinder = + 0,002 M
2 (932,2297 atm)(0,85) - 0,6 x 3 atm

tsilinder = 0,024 m = 0,073 in


Digunakan tebal standar untuk shell: 3/16 in = 0,1875 in

3. Menentukan Tebal Head


OD = ID + (2 x ts)
= 76,77 in + (2 x 3/16 in)
= 77,145 in
Dari Tabel 5.7 Brownell and Young:
Icr = 1,98 in
rc = 30 in

W
1
43 r
icr 
W = 1,723 in

44,088 psi (30 in) (1,723 in)


thead = + 0,7874 in
2 (13700 psi)(0,85)- 0,2 x 88,1757 psi

thead = 0,885 in

thead standar = 1,75 in maka tebal yang digunakan:

thead = 1,75 in
C-166

Untuk tebal head 1,75 in,dari tabel 5,8 Brownell and Young maka:
Sf = 1,5 – 4,5 in
Diambil sf = 3,5 in

ID 2
b = rc -√(rc -icr )2 - ( 2 -icr )

76,77 in 2
b = 30 in -√(30 in-1,98 in)2 - ( 2 -1,98 in)

b = 51 in
= 1,3 m

4. Tinggi Head (OA)


Dari Tabel 5.8 Brownell and Young, untuk ketebalan head = 1,75 in, sf = 1,5 -
4,5 in, dan dipilih sf = 3,5 in.
OA = th + b + sf
= 1,75 + 51 + 3,5
= 56,25 in
= 1,43 m
AB = ri - icr
= 38,39 in – 1,98 in
= 36,41 in
= 0,925 m
BC = rc - icr
= 30 in – 1,98 in
= 28,02 in
= 0,712 m

AC = √AB2 -BC2

=√36,412 -28,022

= 23,250 in
= 0,59 m
C-167

5. Tinggi Menara
Data perhitungan:
Diameter kolom, Dc = 1,95 m
Luas kolom, Ac = 2,985 m2
Volume head = 0,000049 (D3)
= 0,000049 (1,95)3
= 0,0003633 m3
π
Volume head pada sf = 4 x ID2 x sf

= 3,14/4 x (76,77 in)2 x 3,5


= 16192,76 in3
= 0,2654 m3
Volume total Head = Vhead tanpa sf + Vhead pada sf
= 0,0003633 m3 + 0,2654 m3
= 0,2657 m3
Blank diameter = OD + OD/24 + 2sf +2/3.icr
= 77,145 in + 77,145 in/24 + 2 (3,5 in) + 2/3 (1,98)
= 88,679 in
Untuk bagian bottom kolom:
L
Q = ρL
11379.36
Q = 1014

Q = 11,222 m3/jam
Q = 0,187 m3/menit
Waktu tinggal dibawah plate terakhir: 5 – 10 menit (Ulrich,1984). Waktu
tinggal cairan dipilih = 5 menit.
Vcairan = Q x waktu tinggal
= 0,187 m3/menit x 5 menit
= 0,935 m3
Tinggi cairan dalam shell (HL):
π
Vcairan = 4 Dc2 HL

HL = 4,53 m
C-168

6. Tinggi Total Menara


Jarak dari plate teratas =1m
Tinggi penyangga menara =1m
Jumlah plate = 12 buah
Tebal plate = 0,005 m
Tinggi head + tebal head = OA – sf
= 1,43 m – 0,089 m = 1,341 m
Tinggi plate terbawah = HL + (OA –sf)
= 1,403 m
Tinggi total = 1 + (14 x 0,3) + 0,005 + 1,341 + 1,403
= 7,4 m
= 313,976 in

H. Menentukan Perpipaan dan Nozzle Produk dan Umpan


a. Pipa Feed
Diketahui:
G = 20.745,88 kg/jam = 5,762 g/s
μ = 0,441 cp = 4,441 x 10-4 Pa.s
ρ = 984,376 kg/m3
G
Debit Aliran (Q) =
ρ
20.745,88 kg/jam
=
984,376 kg/m3

= 21,075 m3/jam
= 5,85 x 10-3 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 5,7200,52 x (0,441 x 10-3)0,03 x 984 30,37
= 54,314 mm
= 3,277 in
C-169

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 3 in
Schedule Member = 40 (standar)
ID = 3,068 in = 0,077 m
OD = 3,5 in
A’ = 7,38 in2 = 0,804 ft2
Kecepatan Aliran Feed (V) = 1,229 m/s
Nre = 213873,0579
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 3 in
OD of pipe = 3,5 in

b. Pipa Gas Keluar dari Puncak Menara


Diketahui:
G = 9.366,52 kg/jam = 2,602 g/s
π = 0,257 cp = 2,57 x 10-4 Pa.s
ρ = 822,667 kg/m3
G
Debit Aliran (Q) = ρ

9.366,52 kg/jam
=
822,667 kg/m3

= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
C-170

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,023 m/s
Nre = 205444,4092
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

c. Pipa Cairan Refluks di Puncak Menara


Diketahui:
G = 9.366,52 kg/jam = 2,602 g/s
π = 0,257 cp = 2,57 x 10-4 Pa.s
ρ = 822,667 kg/m3
G
Debit Aliran (Q) = ρ
9.366,52 kg/jam
= 822,667 kg/m3

= 11,385 m3/jam
= 0,003 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 2,602 0,52 x (2,57 x 10-4)0,03 x 822,667-0,37
= 37,769 mm
= 2,427 in
C-171

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,023 m/s
Nre = 205444,4092
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

d. Pipa Cairan Keluar dari Dasar Menara


Diketahui:
G = 11.379,36 kg/jam = 3,160 g/s
π = 0,301 cp = 3,01 x 10-4 Pa.s
ρ = 1205,59 kg/m3
G
Debit Aliran (Q) = ρ
11.379,36 kg/jam
= 1205,59 kg/m3

= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
C-172

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,213 m/s
Nre = 11996565,94
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

e. Pipa Vapor Keluaran Reboiler


Diketahui:
G = 11.379,36 kg/jam = 3,160 g/s
π = 0,301 cp = 3,01 x 10-4 Pa.s
ρ = 1205,59 kg/m3
G
Debit Aliran (Q) = ρ
11.379,36 kg/jam
= 1205,59 kg/m3

= 9,438 m3/jam
= 0,002 m3/s
Asumsi aliran adalah turbulen, Nre > 4000
Di, optimum = 352,8 G0,52 x π0,03 x ρ-0,37
= 352,8 x 3,160 0,52 x (3,01 x 10-4)0,03 x 1205,59 -0,37
= 36,454 mm
= 2,344 in
C-173

Dipilih spesifikasi pipa (Kern,1965, Tabel 11, hal 844):


Nominal pipe standar (NPS) = 2 ½ in
Schedule Member = 40 (standar)
ID = 2,469 in = 0,052 m
OD = 2,88 in
A’ = 4,79 in2 = 0,003 m2
Kecepatan Aliran Feed (V) = 1,213 m/s
Nre = 11996565,94
Sehingga asumsi aliran turbulen benar
Berdasarkan spesifikasi pipa standar diatas, ditentukan spesifikasi nozzle standar
untuk pipa feed spesifikasi nozzle standar dari Brownell and Young, 1959,
Appendix F item 1 adalah:
Size = 2 ½ in
OD of pipe = 2,375 in

I. Design Manhole Acces (Shell Manhole)


Manhole merupakan lubang pemeriksaan yang diperlukan pada saat
pembersihan atau pemeriksaan pada bagian dalam kolom. Setiap pressure vessel
yang dalam operasinya melibatkan liquid ataupun vessel yang ada didalamnya
terdapat alat lain seperti impeler, packing, plate dan lainnya sebaiknya dilengkapi
dengan manhole yang tujuannya untuk pemeriksaan dan perbaikan. Untuk vessel
dengan diameter antara 48 in sampai 96 in, digunakan manhole dengan diameter
dalam minimal 15 in. (Megyesy, 1983). Manhole dipasang dengan tujuan sebagai
tempat untuk perbaikan plate.
C-174

Gambar C. 14 Detail Design Manhole

Direncanakan manhole dipasang pada bagian samping sisi kolom sebanyak 2 buah
dengan ukuran standar 20 in berdasarkan rekomendasi API standar 12 C. Maka
konstruksi manhole berdasarkan rekomendasi API standar 12 C (Brownell and
Young, appendix F item 3 dan 4) dengan spesifikasi:
Diameter Manhole (ID) = 20 in
Ketebalan cover plate = 5/8 in
Bolting-flange thickness after finishing = ½ in
Dimensi manhole 20 in berdasarkan rekomendasi API Standard 12 C:
Ketebalan shell manhole = 0,3125 in
Ukuran Fillet Weld A = 0,1875 in
Ukuran Fillet Weld B = 0,3125 in
Approx Radius ® = 5/8 in
Length of Side (L) = 45 in
Width of Renforcing Plate (W) = 54 in
Max Diameter of Hole in Shell = 24,5 in
Inside Diameter of Manhole = 20 in
Diameter Bolt Circle (DB) = 26,25 in
Diameter of Cover Plate (DC) = 28,75 in
C-175

C.21 Reaktor CSTR ( R-01)

Gambar C.15 Tampilan Reaktor


Kode : R-01
Fungsi : Tempat terjadinya reaksi hidrolisa M-formiat
Jenis : Reaktor alir tangki berpengaduk (CSTR)
Jumlah : 1 buah
Tipe perancangan : Silinder tegak dengan flange and dish head (toripsherical)
sebagai tutup atas dan bawah.
Kondisi operasi;
Temperatur : 80°C
Tekanan : 3 atm
Laju alir massa : 20.745,88 kg/jam = 45.736,78 lb/jam
Viskositas campuran : 0,4416127 cp
Dasar pemilihan jenis reaktor dan perancangannya yaitu :
1. Fase Reaksi cair-cair dan prosesnya kontinyu
2. Pada Reaktor Alir Tangki Berpengaduk suhu dan komposisi campuran
dalam reaktor selalu seragam. Hal ini memungkinkan melakukan suatu
proses isotermal dalam reaktor CSTR.
3. Pada Reaktor Alir Tangki Berpengaduk karena volume reaktor relatif besar
dibandingkan dengan Reaktor Alir Pipa, maka waktu tinggal juga besar,
berarti zat pereaksi dapat lebih lama bereaksi di dalam reaktor.
4. Dipilihnya untuk perancangan berupa silinder tegak dengan flange and dish
Head (toripsherical) sebagai tutup atas dan bawah, karena tangki proses
ini dapat dioperasikan pada kisaran tekanan 15 – 200 psig, dan juga
akan di tempatkan pengaduk pada bagian atas.
C-176

Dasar pemilihan pengaduk (Fig. 10.57 Coulson, 1983) yaitu :


Dipilih pengaduk tipe Turbin with 6 flat blade
1. Cocok untuk mempercepat terjadinya perpindahan massa dan panas dalam
bentuk larutan pada sistem yang saling larut, karena pola aliran yang
dihasilkan adalah radial
2. Cocok untuk viskositas campuran sampai dengan 5 x 104 cP.
3. Cocok untuk volume fluida sampai dengan 20.000 galon (2.673ft3)

A. Menentukan Ukuran Tangki


Tabel C.29 Menentukan Konsentasi Umpan Masuk Reaktor
Komponen kg/jam kmol/jam Ƥi (kg/m3) Xi xi/ρi
HCOOCH3 16048.98 267.25 981.2440186 0.7736 0.00079
H2O 4645.73 257.88 997.9860229 0.22394 0.00022
HCOOH 0.00 0.00 1225.180054 1.3E-10 1.1E-13
CH3OH 51.17 1.60 795.7199707 0.00247 3.1E-06
20745.88 526.73 0.00102

1
ρ mix = Xi/ρi (C.125)
1
ρ mix = 0,00102

= 984,375955 kg/m3
= 61,45262 lb/ft3
Laju alir massa
Laju alir volumetrik (V1) = Densitas campuran (C.126)
45.736,78 lb/jam
= 61,45262 lb/ft3

= 744.2607961 ft3/jam
Laju alir mol M-formiat (FAO) = 267,25 kgmol/jam = 594,699935 lbmol/jam
C-177

FAo
Konsentrasi awal M-formiat (CAo) = (C.127)
V1
594,699935 lbmol/jam
= 744.2607961 ft3/jam

= 0,791645282 lbmol/ft3
B. Menentukan Waktu Tinggal Reaktor
Perhitungan waktu tinggal, τ
τ = Vr / V1 (Perry, 1999) (C.128)
713,6399219 ft3
=
744.2607961 ft3/jam

= 0,9499 jam
Volume bahan masuk (Vr) = τ x V umpan
= 0,9499 jam x 20,745 ft3/jam
= 19,70805 m3
= 713,6399 ft3
Faktor keamanan = 20 %
= 20% x Vm
=0,2 x 713,6399219 ft3
= 141,4057 ft3
Volume total = Vf + Vfk (C.129)
= 707,0286 ft3 + 141,4057 ft3
= 848,4344 ft3

C. Diameter Dan Tinggi Tangki


Diameter tangki (Dt)
Volume tangki = volume silinder
Vt = π/4 . Dt2 . H (C.130)
Dimana : H = (3/2) . Dt
h = (1/4) . Dt (Perry’s Chem.Eng, Tabel 6-51)
maka,
Vt = π/4 . Dt2 . (3/2) Dt
3 8 x Vt
Dt = √3xπ
C-178

3 8 x 848,4344 ft3
Dt = √ 3 x 3,14

= 8,965 ft
=107,580534 in
R = 4,482522 ft
= 53,7902 in
Tinggi tangki, H;
H = (3/2) Dt
= (3/2) 8,965 ft
= 13,44756 ft
= 164,371 in

D. Menghitung Tebal Shell


Volume Tutup Tangki (Vh);
π
(Vh) = 24 D3 (Brownell and Young, 1979) (C.131)
π
= 24 (8,965 ft )3

= 99,27048 ft3
Volume cairan dalam Shell (Vc);
(Vc) = Vt – 2Vh (C.132)
= 848,4344 ft3– 2 (99,27048 ft3)
= 659,8934 ft3
Tinggi cairan (h);

(h) = Vc shell (C.133)


D2
π.
4

659,8934 ft3
=
3,14 x (8,965 ft )2 /4

= 10,45921 ft
Perhitungan Tekanan Desain
Pdesain = Phidrostatik + Poperasi (C.134)
C-179

Tekanan hidrostatik :
g
ρ. h.
gc
Phidrostatik = (C.135)
144

Keterangan :
g : Percepatan gravitasi = 32,174 ft/det2
gc : Faktor konversi percepatan gravitasi = 32,1740 g.cm/gf.det2
lb
61,45262 x 10,45921 ft x 1
ft3
=
144
= 4,4635 psia
Poperasi = 3 atm = 44,1psia
Pdesain = 44,1 psia + 4,4635 psia
= 48,5635 psia
Perhitungan Tebal Sheel, t
Bahan yang digunakan adalah stainless steel, dimana :
- Allowable Working Stress (S) = 12650 psia
- Efisiensi sambungan (E) = 0,8
- Faktor korosi = 0,13 – 0,5 mm/ tahun
- Diambil = 0,01 in/ tahun
- Umur alat = 20 tahun
PR
t = SE−0,6 P +(c . n) dimana R = D/2 (Mc Cetta, 1993) (C.136)
48,5635 psia x 53,7902 in
= (12650 psia x 0,8)− 0,6 x48,5635 psia + (0,01 in/tahun x 20 tahun)

= 0,458872 in
Dari tabel 5.4, Brownell, 1979, dipilih tebal tangki standar ½ in.
C-180

E. Ukuran Tutup Atas Tangki

OD

OA
b
icr

ID
B A
Sf

a
C

Gambar C.16 Ukuran Tutup Reaktor


Untuk menentukan bentuk-bentuk head ada 3 pilihan :
1) Flanged and Standard Dished Head
Digunakan untuk vesel proses vertikal bertekanan rendah, terutama
digunakan untuk tangki penyimpan horizontal, serta untuk menyimpan fluida
yang volatil. ( brownell n Young, 1959: hal 86)
2) Torispherical Flanged and Dished Head
Digunakan untuk tangki dengan tekanan dalam rentang 15 psig (1,0020689
atm) sampai 200 psig (13,60919 atm). ( Brownell n Young, 1959: hal 88)
3) Elliptical Flanged and Dished Head
Digunakan untuk tangki dengan tekanan tinggi dalam rentang 100 psig dan
tekanan diatas 200 psig. ( brownell n Young, 1959: hal 92)
Untuk tekanan 3 atm/15 psig maka dipilih torishperical flanged and dished head.
Tutup Reaktor terbuat dari bahan yang sama dengan shell, maka :
Tebal Tutup Tangki = ½ in
Dari Tabel 5.4 Brownel and Young (1979), diperoleh,
Straight flange (Sf) = 2 in
Radius Sudut dalam (icr) = 1 ½ in
Perhitungan Dimensi Reaktor
Dt = ID = r = 8,965 ft
= 107,5805 in
OD = ID + 2 t (C.137)
C-181

= 107,5805 in + 2 (0,458872 in)


= 108,4982 in = 9,04152 ft
Dimensi keseluruhan (OA) = t + b + sf (Brownell and Young, 1979)
Dimana :
OA : Tinggi keseluruhan tutup tangki
a : Radius dalam
b : Pinggang bagian dalam
r : Radius Pinggang

a = ID /2 = 107,5805 in /2 = 53,7902 in
ID
AB = – icr = 53,7902 in - 1,5 = 52,2902 in
2

BC = ID – icr = 107,5805 in – 1,5 in = 106,0805 in


B = ID – √(BC)2 − (AB)2 (C.138)

= 107,5805 in – √(106,0805 in)2 − (52,2902 in)2


= 15,2831in
AC = √(BC)2 − (AB)2 (C.139)

= √(106,0805 in)2 − (52,2902 in)2


= 92,2974 in
OA = t + b + sf (C.140)
= 0,458872 in + 15,2831in + 2 in
= 17,742 in
Jadi tinggi tutup atas = 17,742 in = 1,478502 ft
Tinggi keseluruhan reaktor = 164,371 in x 2(17,742 in)
= 182,113 in
=5,001 m

F. Perancangan Pengaduk
Digunakan jenis six pitched blade turbine. Karena dapat digunakan untuk
campuran berviskositas < 10.000 cp ( Geankoplis 1993,hal 143). Pengaduk didesain
dengan standar sebagai berikut :
C-182

Da : Dt =1:4
W : Dt = 1 : 20
C : Dt =1:4
L : Dt =1:4
Dimana :
Da = Diameter pengaduk
Dt = Diameter tangki
W = Lebar daun pengaduk (blade)
C = Jarak pengaduk dari tangki dasar
L = Panjang daun pengaduk (blade)
J = Lebar baffle
Jadi :
Diameter pengaduk (Da) = 1/3 x Dt = 1/3 x 8,96504 ft = 2,98834 ft
Lebar daun pengaduk (W) = 1/5 x Da = 1/5 x 2,98834 ft = 0,1494 ft
Jarak pengaduk dari tangki dasar (C) = ¼ x Dt = ¼ x 8,96504 ft = 2,2412 ft
Panjang daun pengaduk (L) = ¼ x Dt = ¼ x 8,96504 ft = 2,2412 ft
Diameter batang pengaduk (Dd) = 2/3 Da = 2/3 x 2,98834 ft = 1,9922 ft
Lebar baffle (J) = 0,17 x Dt = 0,17 x 8,96504 ft = 0,508 ft
Tebal baffle = 1/5 x Da = 1/5 x 2,98834 ft = 0,59766 ft
Jarak baffle dari dasar tangki (offset 1) = ½ x Da = ½ x 2,98834 f = 1,4941 ft
Jarak baffle dari permukaan cairan ( offset 2) = 1/6 x J = 1/6 x 0,508 ft = 0,08466 ft
C-183

Gambar C.17 Dimensi Reaktor, Impeller Dan Baffle

1. Jumlah impeller yang digunakan:


Menurut Dickey (1984) dalam Walas 1990 Hal. 288, kriteria jumlah
impeller yang digunakan didasarkan pada viskositas liquid dan rasio ketinggian (H)
terhadap diameter tangki (Dt).
Diketahui bahwa :
Dt = 107,5805 in
Ht = 164,371 in
Ht /Dt = 1,5
µ = 0.4416127 Cp

Tabel C.30 Pemilihan Jumlah Impeller


Max Clearance
Viskositas, cP Jumlah
H/D lower Upper
<25000 1,5 1 h/3 -
<25000 2,1 2 D/3 (2/3)h
>25000 0,8 1 h/3 -
>25000 1,6 2 D/3 (2/3)h
C-184

Rasio H/D maksimum untuk penggunaan 1 buah impeller adalah 1,5 untuk
viskositas liquid <25000 cP dan rasio H/D = 1,5 maka jumlah impeller yang
digunakan sebanyak 1 buah. Kecepatan putaran motor standar yang tersedia secara
komersil adalah 37, 45, 56, 68, 84, 100, 125, 155, 190 dan 320 rpm (Walas,
1990).
N = 125 rpm = 2 rps
Bilangan Reynold,
ρ (Da)2 N
NRe = (C.141)
µ
lb
61,45262 x (2,98834 ft)2 x 2 rps
ft3
=
0,4416127 cP

= 2.485,3709
Dari gambar 9-13 mc cabe1jilid 1 untuk kurva A diperoleh angka daya,
Np =2
2. Kebutuhan Daya Teoritis :
Np ρN3 D5a
P = (C.142)
gc
lb
2 x 61,45262 x (2)3 .((2,98834 ft))5
ft3
P =
32,174

= 7.283,0168 ft.lbf/s
= 7.283,0168 ft.lbf/s / 2.571,875651
= 2,93035 hp
Efisiensi motor = 80 %
2,93035 hp
Motor yang digunakan =
0,80

= 3,66294 hp

G. Perencanaan Flange pada Sambungan Head dengan Shell


Flange merupakan salah satu aksesoris yang dipasang pada reaktor dengan
fungsi sebagai penghubung dengan sistem perpipaan yang terkoneksi dengan
reaktor. Pada vessel penggunaan flange juga bertujuan untuk memudahkan proses
pembersihan bagian dalam vessel. Digunakan jenis Slip-on flanges karena
C-185

digunakan secara luas, mudah dalam pengelasan dan biaya awalnya rendah. Data
perancangan:
Tekanan desain (p) = 48,64052991 psia
Temperatur desain = 80 0C
Material flange = Stainless steel SA 283 GRADE C
Bolting steel = SA 193 Grade B7 (Brownell and Young, 1959)
Material gasket = Asbestos composition, stainless steel
(Gambar12.11, Brownell and Young, 1959)
Diameter luar shell (B) = 110,3642 in = 9,19702 ft
Ketebalan shell = 0,463757671 in
Diameter dalam shell = 109,4367 in
Tegangan dari material flange = 18.750 psi
Tegangan dari bolting material (fb) = 20.000 psi

Gambar C.18 Tipe Fllange Dan Dimensinya

Perhitungan lebar gasket


do √y-pm
= (C.143)
di y-p(m+1)

Keterangan:
P = tekanan desain (psi)
do = diameter luar gasket (in)
di = diameter dalam gasket (in)
C-186

y = yield stress, lb/in2 (Fig. 12.11)


m = faktor gasket (fig. 12.11)
Dari fig 12.11 Brownell & Young, untuk material gasket Stainless steels diperoleh :
y = 9.000
m = 3,75
do √9000-48,5635 psia x 3,75
=
di 9000 - 48,5635 psia (3,75+1)
do
= 1,000333862
di

Do = 107,5805 in x 1,000333862
= 108,5345 in
Lebar gasket minimum
do-di
N = (C.144)
2
108,5345 in - 107,5805 in
=
2
= 0,018117 in
Keterangan :
N = Lebar gasket minimum (in)
do = Diameter luar gasket (in)
di = Diameter dalam gasket (in)
Digunakan gasket dengan lebar standar 0,25 in (Gambar 12.12, Brownell and
Young,1959).
Diameter gasket rata-rata (G) :
G = di + lebar gasket (C.145)
= 107,5805 in + 0,25 in
= 108,7482 in
Dari Fig 12.12 B & Y, kolom 1, tipe 1.a, didapat :
bo = N/2 (C.146)
=0,25/2
= 0,125 in
C-187

H. Menghitung diameter nozzle reaktor


Direncanakan terdapat 2 nozzle masuk dan 1 nozzle a keluaran reaktor.
1. Nozzle umpan M-formiat
Laju alir umpan masuk = 16144,79 kg/jam = 9,8869 lb/s
Densitas umpan = 61,2571 lb/ft3
Laju Alir
Debit umpan = Densitas (C.147)
9,8869 lb/s
=
61,2571 lb/ft3

= 0,161401361 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas) (C.148)
= 3,9 x (0,161401361 )0,45 x (48,63)0,13
= 2,930 in
Dipilih untuk nozzle pemasukan umpan menggunakan pipa dengan diameter
standar: 3 in
2. Nozzle umpan air
Laju alir umpan masuk H2O = 4645,73 kg/jam = 2,845 lb/s
Densitas umpan = 62,3022 lb/ft3
Laju Alir
Debit umpan =
Densitas
2,845 lb/s
=
62,3022 lb/ft3

= 0,045664 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas)
= 3,9 x (0,045664)0,45 x (48,63)0,13
= 1,6640 in
Dipilih untuk nozzle pemasukan umpan menggunakan pipa dengan diameter
standar: 2 in
3. Nozzle keluaran reaktor
Laju alir umpan masuk = 45.736,7774 lb/jam =12,7046 lb/s
Densitas umpan = 61,4526 lb/ft3
Laju Alir
Debit umpan =
Densitas
C-188

12,7046 lb/s
=
61,4526 lb/ft3

= 0,206739 ft3/s
Diameter optimum = 3,9 x Qf0,45 x ρ0,13 (pers 6.32, Wallas)
= 3,9 x (0,206739 ft3/s)0,45 x (61,4526 lb/ft3)0,13
= 3,277729 in
Dipilih untuk nozzle keluaran reaktor menggunakan pipa dengan diameter standar:
3 ½ in

4. Manhole
Setiap vessel yang dalam operasinya melibatkan cairan ataupun yang di
dalamnya terdapat alat lain seperti impeller, sebaiknya dilengkapi dengan manhole.
Manhole sangat dibutuhkan dalam vessel tertutup untuk pemeriksaan, pembersihan
kolom dan perbaikan. Direncanakan manhole dipasang pada kolom bagian atas
reaktor dengan ukuran standar 20 in berdasarkan rekomendasi API Standard 12 C
(Brownell and Young, Ap. F item 4), dengan spesifikasi :
Tebal shell = 0,3125 in
Tebal flange = 1 ½ in
Jumlah = satu
Ukuran potongan :
Weld A = 7/8 in
Weld B = 1,5 in
Panjang sisi = 42,5 in
Lebar reinforcement (W) = 49 in
Diameter manhole, ID = 20 in
Maksimum diameter lubang,
Dp = 27 in
Diameter plat penutup
cover plate = 28,75 in
Diameter bolt circle, DB = 26,25 in
C-189

I. Desain Skirt Support


Skirt adalah penyangga yang digunakan dan paling aman untuk menyangga
vertical vessel. Skirt disatukan dengan vessel mengunakan pengelasan kontinyu
(Continous welding), ukuran pengelasan ditentukan berdasarkan ketebalan skirt.
Ketebalan dari skirt harus mampu untuk menahan berat mati dan bending moment
dari vessel.
1. Momen pada base
M = Pw. Dis. H. hi (Megyesy, 1983) (C.149)
Keterangan:
Pw = wind pressure = 25 lb/ft2 = 122,060609 kg/m2
Dis = diameter vessel = 2,7558 m
H = tinggi menara total = 5,0001 m
H 5,0001 m
hl = lever arm = H/2 = = = 2,5 m (C.150)
2 2
Momen pada base (M) adalah= Pw. Dis. H. hi (C.151)
= 122,060609 kg/m2 × 2,7558 m× 5,0001 m × 2,5 m
= 4.169,39 kg.m
2. Momen pada ketinggian tertentu (batas antara penyambungan skirt)
MT = M – hT (V – 0,5.PW. Dis. hT) (Megyesy, 1983) (C.152)
Keterangan:
V = total shear = Pw. Dis. H1 (C.153)
= 122,0606 kg/m2 × 2,7558 m × 2,5 m
= 1667,7185 kg
hT = ketinggian skirt =1m
Momen pada batas penyambungan skirt
MT = M – hT (V – 0,5.PW. Dis. hT) (C.154)
= 4.169,39 kg.m - 1 m (1667,7185 kg - 0,5 × 122,0606 kg/m2 × 2,7558 m ×
2,5 m)
= 2.508,5034 kg.m
C-190

3. Menentukan Tebal Skirt


12 × MT
t = 2
(Megyesy, 1983) (C.155)
R × π × S ×E
Keterangan:
MT = momen pada penyambungan skirt & vessel
E = effisiensi penyambungan kolom & skirt = 0,6 (butt joint welding)
R = radius luar dari skirt = 0,76092486 m
S = nilai stress dari head atau material skirt menggunakan bahan carbon steel
= 10000 psi = 7030695,796 kg/m2
Maka,
12 × MT
t = (Megyesy, 1983)(C.156)
R2 × π × S ×E
12 × 2.508,5034 kg.m
=
0,760924862 m2 × 3,14 ×7030695,796 kg/m2 × 0,6

= 0,003924 m = 0,5452 in

J. Perancangan Sistem Pengendalian


Tujuan pengendalian adalah agar reaktor bekerja pada kondisi yang
diharapkan. Instrumen pengendali yang digunakan yaitu:
1. Flow Controller (FC), dengan alat berupa venturimeter, mengatur laju
umpan masuk sehingga selalu sesuai dengan komposisi yang diinginkan.
2. Temperatur Controller (TC), menunjukkan temperatur reaktor dan
mengatur laju alir air pendingin.
3. Level Controller (LC), yang bertujuan untuk menjaga ketinggian cairan
dalam reaktor agar tidak meluap dengan mengatur valve keluaran reaktor.
4. Pressure Controller (PC), menjaga tekanan dalam reaktor