Sei sulla pagina 1di 1

DIRECTIONS FOR USE OF:

ANACONDA LHS www.mtigroup.com.au

BEFORE STARTING: Ensure that


all mesh has been cut away from
the hole to prevent LHS from
puncture

NEEDS COLLAR PIPE ACCEPTABLE


INSERT INTO
UP-HOLE (If required)

STEP 1: Ensure hole is prepared:


The collar of hole must be free from sharp mesh. If collar has mesh or shotcrete with metal (anything that could puncture the LHS), collar pipe must be
used. Cut at least a 500mm length and ensure at least 200-300mm protruding. Collar pipe can be a maximum of 15mm smaller than diameter of hole.

CONNECT
Maximising your explosive capability
ANACONDA
NOT SUITABLE FOR HOLE
DO NOT OVER INFLATE
CLICK

DIRECTIONS FOR USE

GREATER THAN
MAX 10PSI

10m
successful connection.
will be heard upon
force. An audible click
applying a connecting
apposing directions while
twist coupling and bag in
valve, once mating,
Press coupling onto

CLICK !
Maximising your explosive capability
ANACONDA
NOT SUITABLE FOR HOLE
DO NOT OVER INFLATE
CLICK

DIRECTIONS FOR USE

GREATER THAN
MAX 10PSI

10m
successful connection.
will be heard upon
force. An audible click
applying a connecting
apposing directions while
twist coupling and bag in
valve, once mating,
Press coupling onto

STEP 2: Prepare ANACONDA LHS


Select the ANACONDA of length LESS THAN or EQUAL to the depth of the hole to be stabilized. Remove ANACONDA LHS from box and unfold the tail.
Attach inflation coupling.

6
STEP 3: Stabilise hole
Place tail in hole with 300 - 500mm protruding and the
remaining protective tail up/inside the hole. Begin
300mm - 500mm

0 10
psi inflating and stop when pressure reaches between 6 and
10 psi.
Support LHS firmly as when the expansion tube reaches
the toe it will try to push LHS out of the hole.
Disconnect once inflated

CLICK !

AIR
DISCONNECT

IMPORTANT
1) Hole must not breakthrough - if a breakthrough, an AERO plug will need to be placed at the breakthrough. LHS is a self lining product
which needs containment. In the event of large voids, it is recommended to line hole manually first with ANACONDA SHIELD.
2) Hole must be at a depth LESS than or equal to the size marked on the ANACONDA LHS failure to follow will cause product failure.
3) Collar of hole MUST be clear of sharp objects which could puncture LHS - Collar pipe is recommended as protection in severe
conditions
4) Product is not designed to prevent faults, shears or squeeze caused by seismic activity.
5) Product self lines hole, if a hose can be pushed to the end of hole, ANACONDA LHS will make it to the end.

Unit 2/5 Opportunity St, Wangara WA 6065 | E: info@mtigroup.com.au | P: 1300 301 115 | F: +61 (0)8 9302 4899 | www.mtigroup.com.au

Potrebbero piacerti anche