Flow Totaliser cum Controller - Microcompt VERMONT

The Microcompt is a powerful flow computer, designed


m
to meet the requirements of all types of fluid metering
installations. Microcompt is designed for refuellers, *— <9. <*
4
z:
I
tank trucks, marine and process batching applications.
%
Ei-" -.air*'

The Microcompt comes in two enclosures, first


Standard Explosion proof enclosure for all hazardous
area and second non-exproof (weatherproof) version.
'

W09L £ ®l
SALIENT FEATURES %
Exproof Microcompt Version
Self-diagnostic
Meter error curve linearization
Alphanumeric 20 x 2 backlit LCD display
n Tamper-proof and sealed calibration facility and

approved by Weights & Measures department jejaoSj1

Accepts all types of interlocks for fail-safe operation


Can be used with any make of flow meters and
pulse
'
RS-232 / RS-485 connectivity
Flameproof enclosure for hazardous area
application approved by PESO Weatherproof to
IP-65 Non-Exproof (Weather Proof) Microcompt Version
IE Mil
Temperature compensator as per API

PRINCIPLE OF OPERATION As Microcompt is designed for truck application,


special features like low frequency / voltage functioning,
Microcompt realizes a self-test at start-up, and also vibration dampening, ticket printing as per customer
periodically during operation, to ensure connectivity with requirement.
external devices and systems.
In the case of sudden power failure during product
The Microcompt can be programmed for a delivery, all the process data is stored into the EEPROM
predetermined product quantity to be loaded prior to a memory of the equipment.
delivery or as a Start / Stop system where unspecified
product quantity can be delivered. In both the options,
relay options are provided to control pumps and tank EQUIPMENT CONFIGURATION
valves. Product delivery is started only after proper
functioning of all the interlocks. The delivery The Microcompt is equipped with a EEPROM memory,
commences with gradual opening of the set stop valve in which all the configuration parameters like multi¬
controlled by the Microcompt. Loading operation point meter K-factors, password and related
parameters like batch quantity, flow rate can be seen on information are stored.
the display.
The parameters are field-settable, with tamperproof
During product delivery, Microcompt constantly monitors sealing facility provided on the rear side of the
the meter flow rate and linearizes the meter accuracy equipment. To configure the parameters, the calibration
curve to give unmatched metering accuracy. window on the rear side is opened and the calibration

Copyright © Vermont - www.vermonttechnologies.co.in


switch is actuated. The parameters can then be edited
by using front push buttons. Once the equipment is
0.25
configured for the required operating conditions, the
0.20 —
switch is de-actuated and the window is sealed.
0.15

0.10
SELF-DIAGNOSTIC FEATURES >, 0.05 —
ra 20 40 60 80. 100
0
During the delivery, Microcompt constantly monitors the 3
-0.05
operating conditions for and logs an alarm if any of the <
s? -0.10
conditions goes beyond threshold limits. These Corrected Accuracy
conditions include - -0.15
Original Curve
Meter over / under speeding -0.20 — Accuracy Curve
Absence of product after valve opening -0.25
Pulse transmitter failure % Flow Rate

Electrical power failure


Interlock failure like vehicle earthing, tank low Linearisation of Meter Accuracy
alarm, etc.

In case of electrical power failure, Microcompt retains Display : Alphanumeric 20 x 2 backlit LCD display
following information in its EEPROM memory -
Memory : 64 KB
Current volume
Accumulated totaliser
Operational flags

INPUTS
PERIPHERALS
PULSE TRANSMITTER
Microcompt may be associated with various types of Type Square wave
peripherals, depending upon the case it will perform as
Frequency 0 to 2000 Hz
either master or slave unit.
No. of Channels Two
Duty Cycle : 50% with 90°
PLC / COMPUTER
ANALOGUE
Microcompt can be connected to a PLC or a computer Type PT-100 three wire RTD
via a MODBUS link. This allows remote control of the Temperature -20°C to +75°C
loading operation, presetting of quantities to be Accuracy +/- 1°C
delivered, recovery of meter data, access control to the Resolution o.rc
loading position, etc. Quantity 1 no.

DIGITAL
PRINTERS Voltage : 12 VDC
Quantity : 2 nos.
Different types of printers can be connected via a serial
link. Microcompt can be interfaced to an industry SERIAL COMMUNICATION
standard Slip Printer and can offer the possibilities of Port-1 : RS-232 for serial printer
printing out all information in the form of a loading ticket. Port-2 : RS 485 optically isolated,
for host communication
STANDARD SPECIFICATIONS Protocol : MODBUS RTU
Baud Rate : Programmable to 4800 / 38400 BPS
POWER REQUIREMENT
Voltage : 12 VDC / 24 VDC / 110 VAC / 230 VAC
Current : 200 mAmp
Data Entry : 4 nos. multi-function push button keys