Sei sulla pagina 1di 2

Steel connections

___________________________________________________________________________________

Family: Column splice (CS)


Type: End plate
Description: 12
Design code: AISC 360-16 LRFD

DEMANDS
Description Pu Load type
[Ton]
---------------------------------------------
DL 70.00 Design
---------------------------------------------

GEOMETRIC CONSIDERATIONS
Dimensions Unit Value Min. value Max. value Sta. References
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
End plate
Thickness [cm] 2.00 0.04 2.54
Horizontal edge distance [cm] 4.00 2.63 -- Tables J3.4,
J3.5
Minimum distance to column edge [cm] 4.00 3.81 --
Number of bolts 10 4 --
Horizontal center-to-center spacing (gage) [cm] 9.04 6.00 -- J3.3
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio References
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
End plate
Yielding of the end plate [Ton] 123.25 70.00 DL 0.57 DG. 24 p.51
Tensile strength of bolts [Ton] 75.39 70.00 DL 0.93 DG. 24 p.51
Bolt tension [Ton] 116.27 70.00 DL 0.60 p. 9-10
Weld capacity [Ton] 102.67 70.00 DL 0.68 Eq. J2-4
Column
Tension yielding [Ton] 274.66 70.00 DL 0.25 Eq. D2-1
Tension rupture [Ton] 286.11 70.00 DL 0.24 Eq. J4-2
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Global critical strength ratio 0.93
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------