CALCULATION WEYMOUTH :
/
T P −P [ DESIGN DATA ]
.
Q = 433.45 × d × Pipe Size = 6
P LST
D = 6.625 in
Where is ∶
Q = Rate of gas flow , cu ft/24hr measured at standard t = 0.28 in
conditions d = 6.065 in
d = Internal Diameter of pipe in. 2.667
P = Initial Pressure , psia d = 122.408
P = Terminal pressure, psia P2 = 314.7 psia
L = Lenght of line, miles.
S = Spesific gravity flowing gas (air = 1). PS = 14.7 psia
T = Absolute temp. flowing gas (°F. +460) L = 70 km = 43.40 mile
T = Standard absolute temp. flowing gas (°F. +460)
P = Standard Pressure
S = 0.65
0 0
T = 100 F= 560 R
0 0
TS = 60 F= 520 R
QS = 10000 MSCFD
/ Q × L. S. T /
P −P =
T
433.45 × P × d .
(1) L. S. T 1/2
= √ 43.40 x 0.65 x 560 = √ 15797.6
= 125.69
(3) d = 6.065
d 2.667
= 122.408
= 669.67
P1 2 − P2 2 = 669.67
2
2 2
P1 2 = P2 + 669.67
P1 = √ 99036.09 + 448457.78
P1 = 739.93 psia