Sei sulla pagina 1di 2

Project: Made By:

Location: Checked By:


Client: Date:
Job Title Job.No/ Rev.

OUTRIGGER PAD DESIGN REF.

1. CRANE OUTRIGGER PAD GEOMETRY: Concrete

sHP = Rect. unitless Shape of the Outrigger Pad Mobile Crane

1.10
x_dim = 750.00 mm Distance along X-direction Manual
y_dim = 750.00 mm Distance along Y-direction
A_p = 5.63E+05 mm² Area of the Outrigger pad

2. LOADINGS:
1.10
Ps = 1137.62 kN Concentrated load from the Outrigger" PLAN pre-calculated
L = 1.40 unitless Load factor assumption
IM = 1.20 unitless Impact Factor assumption
1137.62
Pu = 1365.14 kN Ps+0.40Ps+0.20Ps, Factored load

3. BASE PROPERTIES:

Type = Concrete unitless Type of Base for the Pads


b = 981.00 kN/m² Base Bearing Capacity pre-calculated
AR = 1.160 m² Area required

4. PAD SUPPORT DESIGN & ANALYSIS: Timber Beam


4.1 MAT PROPERTIES: Concrete
Consider Douglas Fir- Larch, Select Structural NDS - 2005
Type = Timber unitless Mat Material ELEVATION
Fb = 1500.00 Mpa Bending Stress
Fv = 170.00 Mpa Shearing Stress Y
Fcp = 625 00 Mpa
625.00 Compressive Stress (perpendicular to the grain) d
ds
E = 1.60E+06 Mpa Modulus of Elasticity
d= 150.00 mm Standard thickness
b= 200.00 mm Standard width X
ds = 137.50 mm Dressed thickness
bs
bs = 187.50 mm Dressed width
A = 2.66E+04 mm² Gross Section Area
Sxx = 8.06E+05 mm³ Section Modulus along X-axis
Ixx = 8.05E+07 mm4 Moment of Inertia along X-axis
CROSS SECTION
Syy = 6.20E+05 mm³ Section Modulus along Y-axis
Iyy = 4.33E+07 mm4 Moment of Inertia along Y-axis
wt = 12.813 kg/m Weight of mat per meter 1365.14

4.2 CALCULATE THE FORCES CONSIDERED IN DESIGN:


AR = 1.16 m² Ps /  b, Area required
Ap = 1.20 m² Base Area provided
Lr = 1.10 m Actual Mats effective base Length
Wr = 1.10 m Actual Mats effective base Width
Lc = 0.73 m (Lr-x_dim)/2, Actual Mats cantilever length
qu = 1177.31 kN/m² (Pu/Ar)+(Wt of Mat) Factored Pressure on the base
Mu = 783.5 kNm quWrLr²/2, Factored Bending Moment
Vu = 1246.48 kN quWr(Lr-ds), Factored Shear Force
Timber Beam
Ru = 1365.14 kN Compressive force for Bearing Check

4.3 CALCULATE THE ADJUSTED STRENGTH OF THE MATS: 1177.31 NDS - 2005
Adjustment Factors for Bending, Shear & Bearing: 1.10
Cd = 1.00 unitless Load duration factor (Conservative Value) C2.3.2
Cm = 1.00 unitless Wet service factor
783.5
Ct = 1.00 unitless Temperature factor
CL = 1.00 unitless Beam stability factor
Cf = 1.00 unitless Size factor
Cfu = 1.00 unitless Flat use factor 1246.48
Ci = 0.80 unitless incising factor (0.80 Fb,Fv, 1.0 Fcp)
Cr = 1.00 unitless Repetitive member factor
Cb = 0.75 unitless Bearing Area Factor
0.73
Fb' = 1200.00 Mpa FbCdCmCtClCfCfuCiCr,Adjusted Bending Stress Table M4.3-1
Fv' = 136.00 Mpa FvCdCmCiCt, Adjusted Shearing Stress
Fcp' = 468.75 Mpa FcpCmCtCiCb, Adjusted Compressive Stress (perpendicular to the grain)

D:\Cris Files\old drive d\Calculation Files\Excel Sheet File\Outrigger Pad Design By: CGB
Project: KAFD Monorail System 8475 Made By: CGB
Location: Riyadh, Kingdom of Saudi Arabia Checked By:
Client: KAFD Date: 10-May-15
Job Title OUTRIGGER PAD DESIGN Job.No/ Rev. 000

OUTRIGGER PAD DESIGN REF.

4.4 CALCULATE THE STRENGTH OF THE PROFILE SECTION: NDS - 2005

A. Bending Moment:
Fb' = 1200.00 Mpa Adjusted Bending Stress
Sxx = 8.06E+05 mm³ Section Modulus along X-axis
M' = 966.75 kNm Fb'xSxx, Adjusted Bending Moment M3.3-2
Mu = 783.50 kNm Factored Bending Moment

B. Shear Force: V' > Vu


Fv' = 136.00 Mpa Adjusted Shearing Stress
A = 2.66E+04 mm² Gross Section Area
V' = 2412.90 kN 2/3Fv'A, Adjusted Shear Capacity parallel to the grain M3.4-3
Vu = 1246.48 kN Factored Shear Force

C. Bearing Capacity:
Fcp' = 468.75 Mpa Adjusted Compressive Stress (perpendicular to the grain)
Ab = 1.41E+05 mm² Bearing Area of 1 unit of Timber
R' = 65917.97 kN Fcp'A, Adjusted Compressive (perpendicular to the grain) M3.10-2
Ru = 1365.14 kN Compressive force for Bearing Check

5. SUMMARY RESULTS:
NDS - 2005
A. Bending Moment: M' > Mu M3.3-1
Rem = OK unitless Remarks
Utiliz = 0.81 unitless Utilization Ratio

B. Shear Force: V'


B V > Vu M3 4 1
M3.4-1
Rem = OK unitless Remarks
Utiliz = 0.52 unitless Utilization Ratio

C. Bearing Force: R' > Ru M3.10-1


Rem = OK unitless Remarks
Utiliz = 0.02 unitless Utilization Ratio

D. Base Support Bearing Capacity:


b = 981.00 kN/m² Base Bearing Capacity
ba = 948.02 kN/m² Actual Base Bearing Stress
Rem = OK unitless Remarks
Utiliz = 0.97 unitless Utilization Ratio

RESULT = OK unitless OVERALL RESULTS

D:\Cris Files\old drive d\Calculation Files\Excel Sheet File\Outrigger Pad Design By: CGB