DSEGenset®

DSE8610 MKII SPECIFICATIONS

DC SUPPLY
CONTINUOUS VOLTAGE RATING
SYNCHRONISING AUTO START 5 V to 35 V Continuous

LOAD SHARE CONTROL MODULE CRANKING DROPOUTS


Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
batteries.LEDs and backlight will not be
maintained during cranking.

MAXIMUM OPERATING CURRENT


530 mA at 12 V, 280 mA at 24 V

MAXIMUM STANDBY CURRENT


320 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

GENERATOR & BUS
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

MAGNETIC PICKUP
VOLTAGE RANGE
KEY FEATURES • 2 configurable volt-free relay KEY BENEFITS +/- 0.5 V to 70 V
• Comprehensive synchronising & outputs • Compatible in load share systems
loadsharing capabilities • 4 configurable analogue/digital containing DSE5500, DSE7500, FREQUENCY RANGE
10,000 Hz (max)
• Built in governor and AVR control inputs DSE8000 and DSE8600 MKII
• Base load (kW export) control • Built in sensors to support 0 V to 10 series. Contact DSE for further INPUTS
DIGITAL INPUTS A TO L
• Positive & negative kVAr export V & 4 mA to 20 mA details Negative switching
control • 12 configurable digital inputs • 132 x 64 pixel ratio display for
• Mains (Utility) decoupling protection • Configurable 5 stage dummy load clarity ANALOGUE INPUTS A TO D
Configurable as:
• 4-Line back-lit LCD text display and load shedding outputs • Real-time clock provides accurate Negative switching digital input
• Multiple Display Languages • CAN, MPU and alternator frequency event logging 0 V to 10 V sensor
4 mA to 20 mA sensor
• Five key menu navigation speed sensing in one variant • Ethernet communication, provides 0 Ω to 480 Ω sensor
• LCD alarm indication • Real time clock builit in advanced remote
• Heated display option available • Manual and automatic fuel pump monitoring. OUTPUTS
OUTPUT A & B (FUEL & StART)
• Customisable power-up text and control • Can be integrated into building 15 A DC at supply voltage
images • Engine run-time scheduler management systems (BMS) and
• DSENet expansion compatibility • Fuel usage monitor and low fuel programmable logic control (PLC) OUTPUTS C & D
8 A AC at ­­­250 V AC (Volt-free)
• Data logging & trending facility level alarms • Increased input and output
• Internal PLC editor • Simultaneous use of all expansion capability via DSENet® AUXILIARY OUTPUTS E to L
2 A DC at supply voltage
• Protections disable feature communication ports • Licence-free PC software
• Fully configurable via PC using • Remote SCADA monitoring via • IP65 rating (with supplied gasket) BUILT IN AVR GOVERNOR CONTROL
USB, RS232, RS485 & Ethernet various DSE software applications offers increased resistance to water MINIMUM LOAD IMPEDANCE
500 Ω
communication • MODBUS RTU & TCP support with ingress Fully isolated
• Front panel configuration with configurable MODBUS pages for • Advanced Internal PLC editor
GAIN VOLTAGE
PIN protection integration into building allows user configurable functions 0 V to 10 V DC
• Power save mode management systems (BMS) to meet specific application Fully isolated
• 3 phase generator sensing and • Advanced SMS messaging requirements.
OFFSET VOLTAGE
protection (additional external modem required) 0 V to 10 V DC
• Generator current and power • Start & stop capability via SMS EXPANSION DEVICES Fully isolated
monitoring (kW, kvar, kVA, pf) messaging • DSE124 CAN/MSC Extender DIMENSIONS
• kW and kvar overload alarms • 3 configurable maintenance alarms • DSE2130 Input Expansion Module OVERALL
• Reverse power alarms • Compatible with a wide range of • DSE2131 Ratio-metric Input 245 mm x 184 mm x 51 mm
9.6” x 7.2” x 2.0”
• Over current protection CAN engines, including tier 4 Expansion Module
• Unbalanced load protection engine support • DSE2133 RTD & Thermo-couple PANEL CUT-OUT
• Independent earth fault protection • Uses DSE Configuration Suite PC Expansion Module 220 mm x 160 mm
8.7” x 6.3”
• Breaker control via fascia buttons Software for simplified configuration • DSE2152 Ratio-metric Output
• Fuel and start outputs configurable Expansion Module MAXIMUM PANEL THICKNESS
8 mm
when using CAN • DSE2157 Output Expansion Module 0.3”
• 8 configurable DC outputs • DSE2548 LED Expansion
STORAGE TEMPERATURE RANGE
-40 °C to +85 °C
-40 °F to +185 °F
RELATED MATERIALS
TITLE PART NO. OPERATING TEMPERATURE RANGE
DSE8610 MKII Installation Instructions 053-182 -30 °C to +70 °C
-40 °F to +185 °F
DSE8610 MKII Operator Manual 057-254
DSE8610 MKII PC Configuration Suite Manual 057-238 HEATED DISPLAY VARIANT
-40 °C to +70 °C
-40 °F to +158 °F
DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA
Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457 055-204/09/15 (1) US
DSEGenset®

DSE8610 MKII ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


BS EN 61000-6-2
SYNCHRONISING AUTO START EMC Generic Immunity Standard for the
Industrial Environment

LOAD SHARE CONTROL MODULE BS EN 61000-6-4


EMC Generic Emission Standard for the
Industrial Environment

ELECTRICAL SAFETY
The DSE8610 MKII is an easy to use Designed to offer increased built KEY LOAD SHARE FEATURES: BS EN 60950
Safety of Information Technology Equipment,
Synchronising Auto Start Control in support for active sensors for • Peak lopping/sharing (with including Electrical Business Equipment
Module suitable for use in a 0 V to 10 V & 4 mA to 20 mA. appropriate DSE mains controller)
multi-generator loadshare system, Comprehensive communication • Sequential set start TEMPERATURE
BS EN 60068-2-1
designed to synchronise up to 32 and system expansion options are • Manual voltage/frequency
Ab/Ae Cold Test -30 oC
generators including electronic and available. adjustment BS EN 60068-2-2
non-electronic engines. • R.O.C.O.F. and vector shift Bb/Be Dry Heat +70 oC
Using the DSE PC Configuration Suite protection
VIBRATION
The DSE8610 MKII monitors the Software allows easy alteration of the • Generator load demand BS EN 60068-2-6
generator and indicates operational operational sequences, timers and • Automatic hours run balancing Ten sweeps in each of three major axes
status and fault conditions, alarms. With all communication ports • Mains (Utility) decoupling 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz
at 2 gn
automatically starting or stopping capable of being active at the same • Mains (Utility) decoupling
the engine on load demand or fault time, the DSE8610 MKII is ideal for a test mode HUMIDITY
condition. wide variety of demanding load share • Dead bus sensing BS EN 60068-2-30
applications. • Bus failure detection Db Damp Heat Cyclic 20/55 oC at 95% RH
48 Hours
System alarms are annunciated on • Direct governor and AVR control BS EN 60068-2-78
the LCD screen (multiple language • Volts and frequency matching Cab Damp Heat Static 40 oC at 93% RH
options available), illuminated LED • kW and kvar load sharing 48 Hours
and audible sounder.­­ • Dead bus synchronising SHOCK
BS EN 60068-2-27
The event log will record 250 events Three shocks in each of three major axes
15 gn in 11 mS
to facilitate easy maintenance, and an
extensive number of fixed and flexible DEGREES OF PROTECTION
monitoring, metering and protection PROVIDED BY ENCLOSURES
features are included. BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE


VARIETY OF LOAD SHARE APPLICATIONS
DSE2130
DSE2131 MODEM MODBUS PC
DSE2133
DSE2152 2 12 8 4
DSE2157
DSE2548 232 485

DSENET® RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 8-35V

ETHERNET
+

DEUTZ DETROIT
DSE8610 MKII MSC
ISUZU
PERKINS
IVECO
JOHN DEERE
CATERPILLAR LOMBARDINI
MTU SISU
7 VOLVO JCB DIESELMAX
55xx 75xx 8xxx 8xxx MKII
CUMMINS YANMAR
OTHER SCANIA AND OTHERS

BUS VOLT FREE GENERATOR SENSING FUEL & START CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
CURRENT VOLTS D+
+ W/L

1ph 2 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E/N N

ISSUE 3