Sei sulla pagina 1di 14

Zelio Plug-In Relays

RXM miniature relays


Data Bulletin
2014
Introduction Zelio™ Plug-In Relays
RXM miniature relays

7 Introduction of the product range


2 The RXM miniature relay range includes:
1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with
4 C/O contacts and 3 A “low level” relays with 4 C/O contacts. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor).
4 Metal hold-down clip for all sockets.
1 5 Plastic hold-down ejector clip for all sockets.
6 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify wiring when creating a jumper between the coil terminals.
4 7 Clip-in ID tags for all the sockets except RXZE2M114.

or

5
6
3 Relay description
1 Spring return push-to-test button for checking contact operation (green: DC coil,
8 red: AC coil).
1 2 Mechanical “relay status” indicator.
2 3 Optional removable lock-down door enables continuous engagement of the
contacts for test or maintenance purposes. During normal operation, this
3
lock-down door must always be in the closed position.
4 4 Bipolar LED indicating the relay status.
5 Removable ID tag for relay identification.
76 5 6 Four notches for DIN rail mounting adapter or panel mounting adapter with
mounting lugs.
7 Eight, eleven or fourteen quick-connect pins.
9 9 10 8 Finger grips for easy removal of the relay from a socket.
9 Mounting adapter for direct mounting of the relay on a panel.
10 Mounting adapter for direct mounting of the relay on a DIN rail.

6
Socket description
1 Sockets with mixed contact terminals (1)
1 Connection by screw clamp terminals or box lug connector.
2 Fourteen female contacts for the relay pins.
Outputs 3 Location for protection modules.
4 Locking components for plastic and metal hold-down clips.
2 5 Locating slot for mounting on DIN rail.
6 Two or four mounting holes for panel mounting.
4
3

Inputs

5 5 Relay coil
terminals
7 Sockets with separate contact terminals (2)
1 2 1 Connection by screw connector.
Inputs
2 Connection by push-in spring clamp terminals. No tool is required to insert the
cable.
3 Eight, eleven or fourteen female contacts for the relay pins.
4 Location for protection modules.
Outputs 5 Locking components for plastic and metal hold-down clips.
6 Locating slot for mounting on DIN rail.
3
7 Two mounting holes for panel mounting.
5 8 Location for bus jumpers (see “Mounting on Sockets” section on
4 www.schneider-electric.com).
9 Location for clip-in ID tag.

(1) The inputs are mixed with the relay coil terminals, with the outputs being located on the
opposite side of the socket.
(2) The inputs and outputs are separated from the relay coil terminals.
6 8 6 Relay coil terminals 6 9

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

3
Specifications Zelio™ Plug-In Relays
RXM miniature relays

General specifications
Conforming to standards IEC/EN 61810-1, UL 508, CSA C22-2 n° 14
Product certifications cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8; CSA; CE; Lloyds
Register; GOST; RoHS compliant
Ambient air temperature Storage °C (F) - 40… + 85 (-40... +185)
around the device Operation °C (F) - 40… + 55 (-40... +131)
Vibration resistance In operation 3 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clip
conforming to Not operating 5 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clip
IEC/EN 60068-2-6
Degree of protection Conforming to IP 40
IEC/EN 60529
Shock resistance In operation 10 gn (11 ms) with retention clip
conforming to Not operating 30 gn (11 ms) with retention clip
IEC/EN 60068-2-27
Protection category RT I
Mounting position Any
Insulation specifications
Rated insulation voltage (Ui) V 250 (IEC), 300 (UL, CSA)
Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 ms) for RXM 2ppppp and RXM 3ppppp; 2.5 (1.2/50 ms) for RXM 4ppppp
Dielectric strength Between coil/contact Vac 2000
(rms voltage) Between poles Vac 2000
Between contacts Vac 1300
Contact specifications
Relay type RXM 2ABppp RXM 3ABppp RXM 4ABppp RXM 4GBppp
Number and type of contacts 2 C/O 3 C/O 4 C/O 4 C/O low level
Contact materials Ag alloy with Au flash Ag with Au flash -
bifurcated
Conventional thermal For ambient A 12 10 6 3
current (Ith) temperature y 55 °C
Rated operational current Conforming to N.O. 12 10 6 2
in utilization categories IEC N.C. 6 5 3 1
AC-1 and DC-1
Switching current Minimum mA 10 3
Switching voltage Maximum V 250 Vac / 28 Vdc (IEC); 300 Vac / 30 Vdc (UL)
Minimum V 17 Vdc 5 Vdc
Nominal load A 12 at 250 Vac (100K cycles) 10 at 250 Vac (100K cycles) 6 at 250 Vac (100K cycles) 3 at 250 Vac (100K cycles)(1)
(conforming to IEC,
resistive, 100K cycles) A 12 at 28 Vdc (100K cycles) 10 at 28 Vdc (100K cycles) 6 at 28 Vdc (100K cycles) 3 at 28 Vdc (100K cycles)(1)
Rated operational Resistive A 12 at 277 Vac (100K cycles) 10 at 277 Vac (100K cycles) 6 at 277 Vac (200K cycles) 3 at 277 Vac (100K cycles)(1)
current (conforming A 12 at 120 Vac (200K cycles) 10 at 120 Vac (200K cycles) 8 at 120 Vac (200K cycles) 3 at 120 Vdc (100K cycles)(1)
to UL)
A 12 at 30 Vdc (100K cycles) 10 at 30 Vdc (100K cycles) 8 at 30 Vdc (200K cycles) 3 at 30 Vdc (100K cycles)(1)
Motor hp 1/2 at 120 Vac (6K cycles) 1/3 at 120 Vac (6K cycles) 1/3 at 120 Vac (6K cycles) 1/16 at 120 Vac (6K cycles)(1)
hp 1 at 277 Vac (6K cycles) 1 at 277 Vac (6K cycles) 1/2 at 277 Vac (6K cycles) 2.8 A FLA at 120 Vac
Pilot Duty B300 B300 B300 5 A make, 0.5 A break, 3A
continuous at 120 Vac(1)
Switching capacity Maximum AC VA 3000 2500 1500 750
DC W 336 280 168 84
Minimum mW 170 15
Maximum operating rate No-load 18 000
In operating cycles per hour Under load 1200
Utilization coefficient 20 %
Mechanical durability Cycles 10 000 000
(1) When mounted horizontally

Electrical durability of contacts Reduction coefficient for inductive load (AC) Maximum switching capacity on resistive load
Resistive load (AC) (depending on power factor cos j) (DC)
Reduction coefficient (A)

1
Durability (Number of operating cycles)

Current c

0,8
0,6
107 10
0,5
6
3
0,4
106 1
A B
D A B D C
C
105 0,3 0,1
0 1 2 3 1 0,6 0,4 0,2 0 28 50 100 150 200 250
Switching capacity (kVA) Voltage (Vdc)

A RXM 2ABppp B RXM 3ABppp C RXM 4ABppp D RXM 4GBppp Durability (inductive load) = durability (resistive load) x reduction coefficient.
Introduction: Specifications References: Dimensions: Wiring:
page 2 page 4 page 6 page 9 page 12

4
Specifications (continued) Zelio™ Plug-In Relays
RXM miniature relays

Coil specifications
Average consumption AC VA 0.9–1.2
DC W 0.8–1.1
Drop-out voltage threshold AC u 0.15 Uc
DC u 0.1 Uc
Operating time Between coil energization AC ms 20 (max.)
(response time) and making of the DC ms 20 (max.)
On-delay contact
Between coil de-energization AC ms 20 (max.)
and making of the DC ms 20 (max.)
Off-delay contact
Control circuit voltage Uc V 12 24 48 110 120 125 220 230 240
Relay control voltage codes JD BD ED FD – GD MD – –
DC supply Average resistance at 20 °C ± 10% W 160 650 2560 13 440 – 17 360 48 400 – –
Operating voltage limits Min. Vac 9.6 19.2 38.4 88 – 100 176 – –
Max. Vac 13.2 26.4 52.8 121 – 138 242 – –
Relay control voltage codes – B7 E7 F7 – – P7 U7
AC supply Average resistance at 20 °C ± 15% W – 177 708 – 3630 – – 16 270 17 720
Operating voltage limits Min. Vdc – 19.2 38.4 – 96 – – 184 192
Max. Vdc – 26.4 52.8 – 132 – – 253 264
Socket specifications
Socket type RXZE2S108M RXZE2S111M RXZE2S114M RXZE2S114S RXZE2M114M RXZE2M114
Relay types used RXM2ppppp RXM3ppppp RXM4ppppp RXM2ppppp RXM2ppppp (1) RXM2ppppp (1)
RXM4ppppp RXM4ppppp RXM4ppppp
Contact terminal arrangement Separate Mixed
Wire connection method Box lug connectors Spring clamp Box lug connectors Screw clamp
terminals terminals
Product certifications cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; GOST; Lloyds; RoHS compliant
Conforming to standards IEC 61984, UL 508, CSA 22.2 No. 14
Electrical specifications
Conventional thermal current (Ith) A 12 10 12 (2-Pole), 10
6 (4-Pole)
Maximum operating voltage Vac 250 (IEC)
Insulation specifications
Between adjacent output contacts Vrms 2500
Between input and output contacts Vrms 2500
Between contacts and DIN rail Vrms 2500
General specifications
Ambient air temperature Operation °C (°F) - 40…+ 40 (- 40…+ 104)
around the device Storage °C (°F) - 40…+ 85 (- 40…+ 185)
Degree of protection Conforming to IEC/EN IP 20
60529
Connection Solid wire 1 conductor 0.5…2.5 mm2 - AWG 20…AWG 14 0.5…1.5 mm2 0.5…2.5 mm2 0.5… 1.5 mm2
without mm 9 ~ 11 16 AWG 20…AWG 14 AWG 20…AWG 16
AWG 20…AWG
cable end 2 conductors in.
0.5…1.5 mm2 - AWG 20…AWG 16
0.35 ~ 0.43
Flexible 1 conductor 0.25…2.5 mm2 - AWG 22…AWG 14 0.5…1.5 mm2 0.25…2.5 mm2 0.25…1 mm2
wire with AWG 20…AWG 16 AWG 22…AWG 14 AWG 22…AWG 17
cable end 2 conductors 0.25…1 mm2 - AWG 22…AWG 17 0.5…1.5 mm2 0.25…1 mm2 - AWG 22…AWG 17
AWG 20…AWG 16
Maximum tightening torque / Screw size Nm 1 / M3 screw
Mounting On 35 mm DIN rail / on panel
Mounting on DIN rail By plastic clip
mm By metal By plastic clip
0.098

compression
2.5

in. spring
Terminal referencing IEC, NEMA
Bus jumper (Ith: 5 A) Yes No
Compatibility with the plastic hold-down Yes
ejector clip
Compatibility with the metal hold-down clip Yes
Protection module compatibility All RXM040W, RXM041pp, RXM021pp
Clip-in ID tag compatibility (1)
Yes (see page 6 for more information) (2) No
Wire connection method Screw connector Spring clamp Screw connector Screw clamp
terminals terminals

(1) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.

5
References Zelio™ Plug-In Relays
RXM miniature relays

Miniature relays with lockable test button only (sold in lots of 10)
Control Number and type of contacts - Thermal current (Ith)
circuit 2 C/O - 12 A 3 C/O - 10 A 4 C/O - 6 A
voltage
Unit Weight Unit Weight Unit Weight
reference reference reference
V kg (lb) kg (lb) kg (lb)
12 Vdc RXM2AB1JD 0.037 (0.082) RXM3AB1JD 0.037 (0.082) RXM4AB1JD 0.037 (0.082)
24 Vdc RXM2AB1BD 0.037 (0.082) RXM3AB1BD 0.037 (0.082) RXM4AB1BD 0.037 (0.082)
RXM4AB1BD 48 Vdc RXM2AB1ED 0.037 (0.082) RXM3AB1ED 0.037 (0.082) RXM4AB1ED 0.037 (0.082)
110 Vdc RXM2AB1FD 0.037 (0.082) RXM3AB1FD 0.037 (0.082) RXM4AB1FD 0.037 (0.082)
220 Vdc – – – – RXM4AB1MD 0.037 (0.082)

24 Vac RXM2AB1B7 0.037 (0.082) RXM3AB1B7 0.037 (0.082) RXM4AB1B7 0.037 (0.082)
48 Vac RXM2AB1E7 0.037 (0.082) RXM3AB1E7 0.037 (0.082) RXM4AB1E7 0.037 (0.082)
120 Vac RXM2AB1F7 0.037 (0.082) RXM3AB1F7 0.037 (0.082) RXM4AB1F7 0.037 (0.082)
230 Vac RXM2AB1P7 0.037 (0.082) RXM3AB1P7 0.037 (0.082) RXM4AB1P7 0.037 (0.082)
240 Vac – – – – RXM4AB1U7 0.037 (0.082)
RXM4AB1F7
Miniature relays with LED and lockable test button (sold in lots of 10)
12 Vdc RXM2AB2JD 0.037 (0.082) RXM3AB2JD 0.037 (0.082) RXM4AB2JD 0.037 (0.082)
24 Vdc RXM2AB2BD 0.037 (0.082) RXM3AB2BD 0.037 (0.082) RXM4AB2BD 0.037 (0.082)
48 Vdc RXM2AB2ED 0.037 (0.082) RXM3AB2ED 0.037 (0.082) RXM4AB2ED 0.037 (0.082)
110 Vdc RXM2AB2FD 0.037 (0.082) RXM3AB2FD 0.037 (0.082) RXM4AB2FD 0.037 (0.082)
125 Vdc – – – – RXM4AB2GD 0.037 (0.082)

24 Vac RXM2AB2B7 0.037 (0.082) RXM3AB2B7 0.037 (0.082) RXM4AB2B7 0.037 (0.082)
RXM4AB2BD
48 Vac RXM2AB2E7 0.037 (0.082) RXM3AB2E7 0.037 (0.082) RXM4AB2E7 0.037 (0.082)
120 Vac RXM2AB2F7 0.037 (0.082) RXM3AB2F7 0.037 (0.082) RXM4AB2F7 0.037 (0.082)
230 Vac RXM2AB2P7 0.037 (0.082) RXM3AB2P7 0.037 (0.082) RXM4AB2P7 0.037 (0.082)

Miniature relays with LED only (sold in lots of 10)


12 Vdc RXM2AB3JD 0.037 (0.082) – – RXM4AB3JD 0.037 (0.082)
24 Vdc RXM2AB3BD 0.037 (0.082) – – RXM4AB3BD 0.037 (0.082)
110 Vdc RXM2AB3FD 0.037 (0.082) – – RXM4AB3FD 0.037 (0.082)
RXM4AB2F7 125 Vdc – – – – RXM4AB3GD 0.037 (0.082)

24 Vac RXM2AB3B7 0.037 (0.082) – – RXM4AB3B7 0.037 (0.082)


48 Vac RXM2AB3E7 0.037 (0.082) – – RXM4AB3E7 0.037 (0.082)
120 Vac RXM2AB3F7 0.037 (0.082) – – RXM4AB3F7 0.037 (0.082)
230 Vac RXM2AB3P7 0.037 (0.082) – – RXM4AB3P7 0.037 (0.082)

RXM2AB3F7

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

6
References (continued) Zelio™ Plug-In Relays
RXM miniature relays

Miniature relays with low level contacts, lockable test button only (sold in lots of 10)
Control Number and type of
circuit contacts Thermal current
voltage (Ith)
4 C/O - 3 A
Unit Weight
reference
V kg (lb)
12 Vdc RXM4GB1JD 0.037 (0.082)
24 Vdc RXM4GB1BD 0.037 (0.082)
48 Vdc RXM4GB1ED 0.037 (0.082)
110 Vdc RXM4GB1FD 0.037 (0.082)

24 Vac RXM4GB1B7 0.037 (0.082)


48 Vac RXM4GB1E7 0.037 (0.082)
120 Vac RXM4GB1F7 0.037 (0.082)
RXM4GB1BD
230 Vac RXM4GB1P7 0.037 (0.082)

Miniature relays with low level contacts, with LED and lockable test button (sold in lots of 10)
12 Vdc RXM4GB2JD 0.037 (0.082)
24 Vdc RXM4GB2BD 0.037 (0.082)
48 Vdc RXM4GB2ED 0.037 (0.082)
110 Vdc RXM4GB2FD 0.037 (0.082)

24 Vac RXM4GB2B7 0.037 (0.082)


48 Vac RXM4GB2E7 0.037 (0.082)
RXM4GB2BD 120 Vac RXM4GB2F7 0.037 (0.082)
230 Vac RXM4GB2P7 0.037 (0.082)
240 Vac RXM4GB2U7 0.037 (0.082)

Miniature relays with low level contacts, with LED only (sold in lots of 10)
12 Vdc RXM4GB3JD 0.037 (0.082)
24 Vdc RXM4GB3BD 0.037 (0.082)
48 Vdc RXM4GB3ED 0.037 (0.082)
110 Vdc RXM4GB3FD 0.037 (0.082)

24 Vac RXM4GB3B7 0.037 (0.082)


48 Vac RXM4GB3E7 0.037 (0.082)
120 Vac RXM4GB3F7 0.037 (0.082)
RXM4GB3F7 230 Vac RXM4GB3P7 0.037 (0.082)

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

7
References (continued) Zelio™ Plug-In Relays
RXM miniature relays

Sockets
Contact terminal Connection Relay type Sold in Unit Weight
arrangement lots of reference kg (lb)
Mixed Screw clamp terminals RXM2pppp (3) 10 RXZE2M114 (1) 0.048 (0.106)
RXM4pppp
Screw connector RXM2pppp (3) 10 RXZE2M114M (1) 0.056 (0.124)
RXM4pppp
Separate Spring clamp terminals RXM2pppp (3) 10 RXZE2S114S (2) 0.070 (0.154)
RXM4pppp
Box lug connector RXM2pppp 10 RXZE2S108M (2) 0.058 (0.128)
RXM3pppp 10 RXZE2S111M (1) 0.066 (0.146)
RXM4pppp 10 RXZE2S114M (1) 0.070 (0.154)

Protection modules
RXZE2M114M Description Voltage For Sold in Unit Weight
+ use with lots of reference
Relay RXM4AB1F7
V kg (lb)
Diode 6...250 Vdc All sockets 20 RXM040W 0.003 (0.007)

RC circuit 24...60 Vac All sockets 20 RXM041BN7 0.010 (0.022)


110...240 Vac All sockets 20 RXM041FU7 0.010 (0.022)

Varistor 6...24 Vac / Vdc All sockets 20 RXM021RB 0.003 (0.007)


24...60 Vac / Vdc All sockets 20 RXM021BN 0.003 (0.007)
RXM041pp7 110...240 Vac / Vdc All sockets 20 RXM021FP 0.003 (0.007)

Timing relays
Description For Unit
use with reference
2 or 4 timed C/O contacts Sockets RXZEppppp REXL2pp (4)
REXL4pp (4)

Accessories
Description For Sold in Unit Weight
use with lots of reference kg (lb)
Metal hold-down clip All sockets 10 RXZ400 0.001 (0.002)
REXL4pp
Plastic hold-down ejector clip All sockets 10 RXZR335 0.005 (0.011)
Bus jumper 2-pole (Ith: 5 A) All sockets with separate contacts 10 RXZS2 0.005 (0.011)

Mounting adapter All relays 10 RXZE2DA 0.004 (0.009)


for DIN rails (5)
Mounting adapter All relays 10 RXZE2FA 0.002 (0.004)
with mounting lugs for panel
Clip-in ID tags All relays (sheet of 108 legends) 10 RXZL520 0.080 (0.176)
RXZ400 All sockets except RXZE2M114 and RXZE2S114S 10 RXZL420 0.001 (0.002)
RXZE2S114S socket 10 RSZL300 0.001 (0.002)
(1) Thermal current Ith: 10A
(2) Thermal current Ith: 12A
(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.
(4) Please consult the "Zelio Time timing relays" catalog.
(5) Test button becomes inaccessible if used with DIN rail mounting adapter or panel mounting adapter and terminals face the user.

8
Dimensions Zelio™ Plug-In Relays
RXM miniature relays

Dimensions
Miniature relays
RXMpppppp RXM2 RXM3 RXM4
Common view Pin side view
mm 6.6 6.6 4.4 4.4 4.4
in. 0.26 0.26 0.17 0.17 0.17
0.25 0.25 0.170.17
6.3 6.3 4.2 4.2

1.06
27
21 21
9 40 6 21 2.5 2.5 2.5 2.5 4.4
0.35 1.58 0.24 0.83 0.10 13.2 0.10 0.10 13.2 0.10 2.5 0.17 2.5
0.52 0.52 0.10 13.2 0.10
0.52
Sockets
RXZE2M114 RXZE2M114M

mm 40 mm 43
in. 1.58 19 in. 1.69 17
25.5
0.75 (4) 1.00 0.67
34 24 44 34 24 14
7 6
8 7 6 5
44 14
8 5 42 32 22 12
42 32 22 12 4 3 2 1
4 3 2 1
3.5 3.5
(1) 0.14 0.14
(1)

3.15
3.11

2.40
79

80
61

39.5
1.56

1.58
40
11
(3) (2) A2 A1 (3) (2) A2 A1
9
14 13 14 13
41 31 21 41 31 21 11

12 11 10 12 11 10 9

(4) 50 23.5
9 21 0.93
0.14

67 1.97
3.5

7 27
23 30 0.35 0.83
0.28 2.64 1.06
30
7 0.91 69 1.18
1.18
0.28 2.72

Common side view RXZE2S108M RXZE2S111M RXZE2S114M

mm 61
in. 2.40 19
0.75
41 11 31 21 11 41 31 21 11
12 9 9 8 7 12 11 10 9
44 14 34 24 14 44 34 24 14
8 5 6 5 4 8 7 6 5
42 12 32 22 12 42 32 22 12
4 1 3 2 1 4 3 2 1

3.5 3.5 3.5


(1) 0.14 0.14 0.14
3.11
79

1.50

(2)
1.50
1.50

(3)
38

38
38

A2 A1 A2 A1 A2 A1

14 13 14 13 14 13
(5)
23 29
0.14
3.5

0.91 1.14 23.5 23.5 23.5


7 70 0.93 0.93 0.93
0.28 2.76 27 27 27
1.06 1.06 1.06

(1) Relays
(2) Protection module
(3) Metal hold-down clip
(4) 2 elongated holes Ø 3.5 x 6.5
(5) 2 bus jumpers

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

9
Dimensions (continued) Zelio™ Plug-In Relays
RXM miniature relays

Dimensions (continued)
Sockets (continued)
RXZE2S114S Socket only RXZE2S114S Socket with RXM relay and retention clip

mm 31
35.5 in. 1.22
mm 31
1.40
in. 1.22
29.5 22
1.16 0.87
23.5
7.5
0.93
0.30

3.70
94
3.86
98
1.10
28

(1)
0.59
15

(3)
3.54
90
3.70
94

(2)
1.89
48

(4) 28
(1) Relay 1.10
52
(2) Protection module 2.05
(3) Metal retention clip 70
0.05

(4) I.D. tag


1.2

2.76
76
2.99

RXZE2S114S Socket with RXM relay and ejector clip

31
mm
in. 1.22
3.70
94
3.86
98

(1)

(3)

(2)

(4)
28
1.10
52
(1) Relay 2.05
(2) Protection module 70
2.76
(3) Ejector clip
80
(4) I.D. tag 3.15

Plastic ejector clip RXZR335 Metal retention clip RXZ400 ID tag RSZL300

57
2.24
0.87
22

8.0
0.3
1.06
27

42
14.5 7.2
1.65
0.6 0.3

0.8
0.03

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

10
Dimensions (continued) Zelio™ Plug-In Relays
RXM miniature relays

Dimensions (continued)
Plastic hold-down clip and clip-in ID tags
RXZR335 RXZL420 Mounting on all sockets (1)

57 26,5
2.24

14,2
(1)

12
1.06
27

94,5
81

(1) Clip-in ID tags for all sockets except


RXZE2M114
Bus jumper Metal hold-down clip
RXZS2 Mounting on sockets with separate contacts RXZ400
(view from below)
Example of bus jumper mounting on sockets

25
0.87
22
7,3
2,2

22 (1) (1)
2,3 42
1.65

(2) (2)
0.8
0.03

(1) 2 bus jumpers (polarity A2)


(2) 2 bus jumpers (polarity A1)

Mounting adapter for rails (1) Mounting adapter for panel


RXZE2DA RXZE2FA
38

43

38
48

3,5 3,5 4
6 4 48 49 24
3

23 24
51

(1) Test button becomes inaccessible

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

11
Wiring diagrams Zelio™ Plug-In Relays
RXM miniature relays

Wiring diagrams
Miniature relays
RXM2ppppp RXM3ppppp RXM4ppppp
A2

A2

A2
12
14
42
44

12
14
22
24
32
34

12
14
22
24
32
34
42
44
A1

A1

A1
11

41

11

21

31

11

21

31

41
1 4 1 2 3 1 2 3 4
12 42 12 22 32 12 22 32 42
5 8 4 5 6 5 6 7 8
14 44 14 24 34 14 24 34 44
9 12 9 10 11 12
7 8 9
11 41 11 21 31 41
11 21 31
13 14 13 14
13 14
A1 A2 A1 A2
A1 A2

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.

Sockets
RXZE2M114 RXZE2M114M RXZE2S108M
7 6 8 7 6 5 12 9
34 24 44 34 24 14 41 11
8 5 8 5
44 14 44 14
4 3 2 1 4 3 2 1 4 1
42 32 22 12 42 32 22 12
42 12
1
5
9
14 13 A2 A1

14 13 9 A2 A1
A2 A1 11 14 13
14 13
12 11 10 41 31 21 11 A2 INPUT A1
41 31 21 12 11 10 9

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.
RXZE2S111M RXZE2S114M RXZE2S114S
9 8 7 12 11 10 9
41 31 21 11
31 21 11 41 31 21 11
12 11 10 9
6 5 4 8 7 6 5
34 24 14 44 34 24 14
44 34 24 14
3 2 1 4 3 2 1
8 7 6 5
32 22 12 42 32 22 12
42 32 22 12
4 3 2 1

A2 A1 A2 A1

A2 A1
14 13 14 13
A2 INPUT A1 A2 INPUT A1 14 13

A2 A1
14 13

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.
Protection modules
RXM040W RXM041ppp RXM021ppp
– A2 – A2 – A2

+ A1 + A1 + A1

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

12
mm 9 ~ 11
in. 0.35 ~ 0.43
Wiring instructions Zelio
(1)

Plug-In Relays (2)
for RXZE2S114S socket RXM miniature relays
mm 9 ~ 11
in. 0.35 ~ 0.43

mm

0.098
2.5
in.
mm 9 ~ 11
in. 0.35 ~ 0.43
Wiring instructions for RXZE2S114S socket
Recommended wire strip length Recommended removal tool: flat blade, Openings for wiring and removal tool
mm parallel tip

0.098
2.5
in. F

(1) (2)

mm 9 ~ 11 mm F

0.098
2.5
in. 0.35 ~ 0.43 in.

(1) (2)

(1) Wiring opening


1 2 (2) Removal tool opening
mm (1) (2)
0.098
2.5

in.
Wiring insertion Wiring removal
F

F F F
F F F
(1) (2)
F F

F
F
1 2

1 2 35.5 1 2 31 3 4
mm 1.40
in. 1.22
F 29.5 22 F
1.16 0.87 F F
23.5 1 7.5 2
Recommended wiring for 0.93RXZE2S114S socket F F
F 0.30
Flexible wiring with 1 wire 0.5 to 1.5 mm2 – 20 to 16 AWG
cable end F F 1
2 wires 0.5 to 1.5 mm2 – 20 to 16 AWG
F 2
Solid wiring without 1 wire 0.5 to 1.5 mm2 – 20 to 16 AWG F
cable end F 2 – 20 to 16 AWG
2 wiresF 0.5 to 1.5 mm
F F
Note: Allow only one wire per terminal opening
1.10

1 2
28

F F
0.59

2
15

1 3
F F
3.54
90
3.70
94

1 2 3 4
F F
1.89
48

F F

F F
1 2 3 4
1 Wiring (cable) terminal opening
2 Removal tool opening
0.05
1.2

1 2 3 4

Introduction: Specifications References: Dimensions: Wiring:


page 2 page 4 page 6 page 9 page 12

13
www.schneider-electric.com
Schneider Electric USA, Inc. The information and dimensions in this catalog are provided for the convenience of our customers.
8001 Knightdale Blvd. While this information is believed to be accurate, Schneider Electric reserves the right to make
Knightdale, NC 27545 updates and changes without prior notification and assumes no liability for any errors or omissions.
USA Customer Care Center
Zelio, Schneider Electric and logo, and “Make the most of your energy” are trademarks or
Tel: 888-778-2733
registered trademarks of Schneider Electric or its affiliates in the United States and other
countries. Other trademarks used herein are the property of their respective owners.
Schneider Electric Canada
5985 McLaughlin Rd.
Design: Schneider Electric
Missassauga, Ontario, Canada L5R 1B8
Photos: Schneider Electric
Canada Customer Care Center
Tel: 800-565-6699

8501DB1301
© 2013–2014 Schneider Electric. All rights reserved. 5/2014