Sei sulla pagina 1di 7

www.hilti.co.uk Hilti PROFIS Rebar 2.4.

12
Company: Page: 1
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:
Specifiers comments:

Design standard: HIT Rebar Design


Application type: All applications/Column on slab

1. Loads 2. Drilling & Temperature 3. Material & Safety

Loads Drilling Structure


Md 68.0 kNm Hole Dry Concrete class (existing C20/25
condition structure)
Md,xz 0.00 kNm
Drilling Hammer Char. yield strength (existing) 500 N/mm²
Nd -35.0 kN method drilling Char. yield strength (new) 500 N/mm²
Highest 42.6 Drilling aid Drilling aid is Cracks
kN/bar used
Cracks along parallel No
Lowest 6.39 Temperature (HIT Rebar Design) member
kN/bar During from 5 °C to
Fire design installation 40 °C
Fire rating None During 20 °C / 20 °C
service
Fatigue design
None
Seismic
Seismic loads No

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:

4. Eurocode 2 parameters 5. Post-installed reinforcement

αcc 0.850 EC2 3.1.6(1) Reinforcements parameters


αct 1.00 EC2 3.1.6(2) Diameter 12.0 mm
Spacing - Y 96.0 mm
αct,bond 1.00
Spacing - X 96.0 mm
εud 0.0200 Table C.1
c 50.0 mm
k2 0.850 EC2 6.5.4(4b) cd (EC2, 8.4.4.1) 42.0 mm
ν' 0.920 EC2 6.5.2(2) Bond conditions Good
ρmax 0.0400 EC2 9.2.1.1 Min. reinforcement 100 mm²/m
εc2 2.00•10-3 Table 3.1 Other
εc2u 3.50•10-3 Table 3.1 Transverse pressure 0.00 N/mm²
Cover of tension force line b 0.00 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:
Selected solution
Bar size Drill bit size Bar spacing - Y Bar spacing - X Distance Drilled hole
centre/centre centre/centre centre/surface required
Φ [mm] D [mm] s [mm] s [mm] cs [mm] ℓvreq [mm]
Bar with highest 12.0 16.0 96.0 96.0 1,056 368
load

Required accessories

Drilling Cleaning Setting


- Suitable rotary hammer - Compressed air with required accessories to - Dispenser including cassette and mixer
- Properly sized drill bit blow from the bottom of the hole - For deep installations, a piston plug is
- Proper diameter wire brush necessary

Bar with highest load (tension)


Design Input

Design force in bar FE 42.6 kN EC2 9.2.1.4(2)


Stress in bars σsd 377 N/mm²
Adhesive used Hilti HIT-RE 500 V3

a) Reactions

M2d -31.6 kNm M3d -31.6 kNm


N2d 0.00 kN N3d 0.00 kN
V2d 17.5 kN V3d -17.5 kN
FT2d 109 kN FT3d 0.00 kN

b) Anchorage Post-Installed Reinforcement

Bond condition Good → η1 1.00 EC2 8.4.3(2)


Bond strength fbd,pi 2.30 N/mm² ETA 16/0142
Basic anchorage length lb,rqd = (Φ/4)•(σsd/fbd,pi) 491 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:
Basic anchorage length (Fyd) lb,rqd,fyd = (Φ/4)•(fyd/fbd,pi) 567 mm

Factor for minimum length fmult,min 1.00


Minimum anchorage length lb,min = fmult,min•max(0.3lb,rqd,fyd; 10Φ; 100 mm) 170 mm EC2 8.4.4(1)
and German
Nationaler
Anhang
Min of clear cover or half spacing cd 42.0 mm > 3Φ EC2
8.4.4(1)
Reduction for large cover δ 0.306

Influence cover/spacing α2' = {1/[1/0.7+δ∙(cd-3Φ)/Φ] ≥ 0.25} 0.632


Influence cover/spacing α2 = {0.7 ≤ 1-0.15[(cd-Φ)/Φ] ≤ 1.0} 0.700

Splitting bond strength fbd,spl = fbd,pi/α2' 3.64 N/mm²


Pullout bond strength fbd,po 9.33 N/mm² ETA 16/0143
Controlling bond strength fbd = max(fbd,pi/α2; min(fbd,spl; fbd,po)) 3.64 N/mm²

Design anchorage length lbd = max[(Φ/4)•(σsd/fbd); lb,min] 311 mm

c) Compressive strut in node

Drill hole depth linst 368 mm


Lever arm inside node z0 = linst-c2-lbd/2 173 mm
Strut angle tan(θF) = z0/z1R → θF 37.0 ° ≥ 30° → ok

Horizontal comp. of strut force Fc0d = (M1d+(V2d+V3d)•z1/2)/z0 394 kN


Compression in strut direction D0d = Fc0d/cosθF 493 kN
Design compressive strength redfcd = αcc•v’•k2•fck/γc 8.86 N/mm²
Resistance of strut D0Rd = redfcd∙lbd∙cosθF 879 kN D0d → ok

d) Splitting force in transition area

Splitting moment Msp,d = Fc0d∙z0∙(1-z0/z2)∙(1-lb1/(2∙z2)) 23.6 kNm


Width of the wall section b 400 mm
2
Resisting moment to splitting Wsp = b∙z2 /2.41 2.66•107 mm³
Splitting stress in slab maxσsp,d = Msp,d/Wsp 0.890 N/mm²
Resistance to splitting αct∙fctk,0.05/γc = 0,85∙fctk,0,05/1,5 1.03 N/mm² ≥ maxσsp,d→ok

e) Tension reinforcement in node

Additional tensile force Hs2d = (M1d+(V2d+V3d)•z1/2)∙(1/z0-1/z2)+V1d∙(z1/z0-1) 224 kN


Tension in top reinforcement 0 ≤ FT0d = FT2d + Hs2d 0.333 kNm
Top reinforcement required As0,rqd = FT0d/(fyk/γs) 766 mm² Amount of
tensile
reinforcement in
the node area
required for
forces out of
connection (in

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:
addition to
previous
loading)

Bar with lowest load (tension)


Design Input

Design force in bar FE 6.39 kN EC2 9.2.1.4(2)


Stress in bars σsd 56.5 N/mm²
Adhesive used Hilti HIT-RE 500 V3

a) Reactions

M2d -31.6 kNm M3d -31.6 kNm


N2d 0.00 kN N3d 0.00 kN
V2d 17.5 kN V3d -17.5 kN
FT2d 106 kN FT3d 0.00 kN

b) Anchorage Post-Installed Reinforcement

Bond condition Good → η1 1.00 EC2 8.4.3(2)


Bond strength fbd,pi 2.30 N/mm² ETA 16/0142
Basic anchorage length lb,rqd = (Φ/4)•(σsd/fbd,pi) 73.7 mm
Basic anchorage length (Fyd) lb,rqd,fyd = (Φ/4)•(fyd/fbd,pi) 567 mm

Factor for minimum length fmult,min 1.00


Minimum anchorage length lb,min = fmult,min•max(0.3lb,rqd,fyd; 10Φ; 100 mm) 170 mm EC2 8.4.4(1)
and German
Nationaler
Anhang
Min of clear cover or half spacing cd 42.0 mm > 3Φ EC2
8.4.4(1)
Reduction for large cover δ 0.306

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 6
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:

Influence cover/spacing α2' = {1/[1/0.7+δ∙(cd-3Φ)/Φ] ≥ 0.25} 0.632


Influence cover/spacing α2 = {0.7 ≤ 1-0.15[(cd-Φ)/Φ] ≤ 1.0} 0.700

Splitting bond strength fbd,spl = fbd,pi/α2' 3.64 N/mm²


Pullout bond strength fbd,po 9.33 N/mm² ETA 16/0143
Controlling bond strength fbd = max(fbd,pi/α2; min(fbd,spl; fbd,po)) 3.64 N/mm²

Design anchorage length lbd = max[(Φ/4)•(σsd/fbd); lb,min] 170 mm

c) Compressive strut in node

Drill hole depth linst 368 mm


Lever arm inside node z0 = linst-c2-lbd/2 243 mm
Strut angle tan(θF) = z0/z1R → θF 46.7 ° ≥ 30° → ok

Horizontal comp. of strut force Fc0d = (M1d+(V2d+V3d)•z1/2)/z0 280 kN


Compression in strut direction D0d = Fc0d/cosθF 408 kN
Design compressive strength redfcd = αcc•v’•k2•fck/γc 8.86 N/mm²
Resistance of strut D0Rd = redfcd∙lbd∙cosθF 414 kN D0d → ok

d) Splitting force in transition area

Splitting moment Msp,d = Fc0d∙z0∙(1-z0/z2)∙(1-lb1/(2∙z2)) 21.0 kNm


Width of the wall section b 400 mm
2
Resisting moment to splitting Wsp = b∙z2 /2.41 2.66•107 mm³
Splitting stress in slab maxσsp,d = Msp,d/Wsp 0.792 N/mm²
Resistance to splitting αct∙fctk,0.05/γc = 0,85∙fctk,0,05/1,5 1.03 N/mm² ≥ maxσsp,d→ok

e) Tension reinforcement in node

Additional tensile force Hs2d = (M1d+(V2d+V3d)•z1/2)∙(1/z0-1/z2)+V1d∙(z1/z0-1) 110 kN


Tension in top reinforcement 0 ≤ FT0d = FT2d + Hs2d 0.216 kNm
Top reinforcement required As0,rqd = FT0d/(fyk/γs) 496 mm² Amount of
tensile
reinforcement in
the node area
required for
forces out of
connection (in
addition to
previous
loading)

Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and
existing concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that
adequate transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The HIT Rebar Design is used in this calculation evaluates solely the strength of the connection; serviceability criteria are not considered.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.4.12
Company: Page: 7
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 03/02/2019
E-Mail:
Indications on displacements and creep of post-installed rebars can be found in the European Technical Approvals for anchors. The Installation
(drilling, cleaning, setting) must be according to the approval!
The user is repsonsible to check the amount of reinforcement in the existing structure. The frame node only works if there is sufficient
reinforcement in the existing part!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Minimum reinforcement requirements are not checked by the software.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Potrebbero piacerti anche