Sei sulla pagina 1di 24

Content

I. F lexible cables for fixed installation or


occasional movements

a. Control cables 4-5


b. Data cables 6-7
c. Single conductors 6-7
d. Motor & Servo cables 8-9
e. Feedback cables 8-9
f. PROFInet / Industrial Ethernet 10-11
g. BUS cables 10-13

II. H
 ighly flexible cables for continuous movements,
such as cable tracks

a. Control cables 14-15


b. Data cables 16-17
c. Single conductors 16-17
d. Motor & Servo cables 18-19
e. Feedback cables 18-19
f. PROFInet / Industrial Ethernet 20-21
g. BUS cables 20-23

5 CABLE QUALIFYING QUESTIONS

1. Are you looking for a flexible cable for fixed installation


or occasional movements (page 4) or a highly flexible cable
for continuous movements (page 14) such as a cable track?
2. W
 hat kind of cable do I need (control cable,
data cable, servo cable, BUS cable, ...)?
3. What kind of jacket material?
4. Shielded or unshielded?
5. Without UL/CSA, with UL/CSA or according to NFPA 79?

Cable track class

Cable Selection Guide Movement distance


(max.)
DC1
5m
DC2
15 m
DC3
50 m

for Industrial Automation


Bending radius (min.) 10 x Ø 7,5 x Ø 7,5 x Ø
Shielded
5xØ
Unshielded
Speed (max.) 2 m/s 3 m/s 5 m/s

Motor, servo, and feedback cables Acceleration (max.) 10 m/s² 10 m/s² 50 m/s²

Single conductor · Control cables


Cycles (min.) 1 Mio 5 Mio 5 Mio
This classification is intended as an initial pre-selection. The exact

Data cables · Bus cables cable track values can be found in Version 27 of the Cables, Wires and
Accessories catalog.

Industrial Ethernet cables Notes


red Halogen-free cables
green Bio-oil & microbe-resistant cables
blue Intrinsically safe cables
*
Oil resistance
Includes page references Please contact us first for special applications.
for Version 27 of the
Cables, Wires & Accessories Dimensions and specifications may change without prior notice.
Errors excepted.
catalog
Content RESEARCH & DEVELOPMENT
I. F lexible cables for fixed installation or We develop optimal, customized cable solutions for our customers.
occasional movements

a. Control cables 4-5 Research and development are the foundation of our work and are an By continuously optimizing our manufacturing processes and procedures,
b. Data cables 6-7 important engine for growth. In interdisciplinary teams we continuously we have become more efficient and economical, and yet we are still able to
c. Single conductors 6-7 develop our products and seek to enhance them for multiple applications. take the complex requirements of a wide variety of applications (such as

d. Motor & Servo cables Moreover, we rely on customer feedback as well as cooperation with regional cables for industrial robots or for applications under cleanroom conditions)
8-9
colleges and research institutes. into account.
e. Feedback cables 8-9
f. PROFInet / Industrial Ethernet 10-11
The materials that will be used are an important starting point of our work. In A crucial stage in the development process of our products is the work done
g. BUS cables 10-13 this regard, we place as much emphasis on searching for and utilizing new in our Test Center. For example, cables suitable for cable track implementation
materials as we do on manufacturing our plastic mixtures (granulates) can be tested with acceleration up to 10 G. Temperature ranges from -50°F
II. Highly flexible cables for continuous movements,
such as cable tracks ourselves, in order to enhance mechanical properties, such as oil resistance, to 482°F (-50°C to +250°C) are simulated in a special climate device so that
temperature range or chemical compatibility. Furthermore, we are capable of track cables can be tested for series production readiness before they are
a. Control cables 14-15
pulling a majority of our copper ourselves, and thus ensure a uniform, high installed in applications like refrigerated warehouses or steel mills.
b. Data cables 16-17
quality relative to properties and workmanship.
c. Single conductors 16-17
d. Motor & Servo cables 18-19
e. Feedback cables 18-19 Our test facilities:
f. PROFInet / Industrial Ethernet 20-21
· Test systems for bending and torsion requirements
g. BUS cables 20-23 · Cable track test systems with movement distances from 4 ft, 10 ft,
16 ft, 20 ft, 60 ft, and 132 ft
· Fire testing systems
5 CABLE QUALIFYING QUESTIONS
· Abrasion testing systems
· Torsion test tower for wind turbines
1. Are you looking for a flexible cable for fixed installation · Aging ovens in accordance with UL, VDE, CSA, HAR, TÜV, CCC
or occasional movements (page 4) or a highly flexible cable
for continuous movements (page 14) such as a cable track?
2. W
 hat kind of cable do I need (control cable,
data cable, servo cable, BUS cable, ...)?
3. What kind of jacket material?
4. Shielded or unshielded?
5. Without UL/CSA, with UL/CSA or according to NFPA 79?

Cable track class PRODUCTION


DC1 DC2 DC3 We specialize in the production of high-quality cables and wires.
Movement distance 5m 15 m 50 m
(max.)
In our two German plants, using the latest production methods, we
Bending radius (min.) 10 x Ø 7,5 x Ø 7,5 x Ø
Shielded manufacture approximately one million conductor kilometers (= 77 times
5xØ around the world) each year . More than 300 qualified employees are
Unshielded
specialized in the production of high-quality standard and specialty cables.
Speed (max.) 2 m/s 3 m/s 5 m/s
Acceleration (max.) 10 m/s² 10 m/s² 50 m/s²
Through use of the latest materials and collaboration with international test

Cycles (min.) 1 Mio 5 Mio 5 Mio institutes, we drive innovation in the areas of automation, data technology,

This classification is intended as an initial pre-selection. The exact building system technology, and renewable energy.
cable track values can be found in Version 27 of the Cables, Wires and Since 2014, in a 75,350 ft² facility in the Chinese city of Taicang (approx. 31
Accessories catalog.
mi northwest of Shanghai) HELUKABEL® has been producing cable and

Notes wires, primarily for the Asian region. As in the German plants, the focus here
is also on high-quality, flexible and highly flexible cables and wires that are
red Halogen-free cables
green Bio-oil & microbe-resistant cables manufactured in accordance with Chinese and international standards. The
blue Intrinsically safe cables use of flexible manufacturing cells enable short delivery times.
*
Oil resistance
Please contact us first for special applications.

Dimensions and specifications may change without prior notice.


Errors excepted.
Continue: PRODUCTION

Our production in numbers:

· 430,560 ft² production area


· 23 extruder systems
· 19 stranding machines
· 50 braiding machines
· Cables & wires from 30 AWG to 2,000 kcmil (0.05 to 1,000 mm²)
· Manufacturing in accordance with: VDE, EAC (GOST-R), UL,
CSA, HAR, CCC, Germanischer Lloyd, TÜV or customer
specification

LOGISTICS
Cable industry logistics redefined.

At its corporate headquarters in the Swabian town of Hemmingen, HELUKABEL® more than 53,820 ft² in the warehouse and 538,200 ft² outdoors enable fast
operates Europe's largest distribution center for cables and wires. This is where deliveries of cable, configured from 1 – 30 kV, to construction sites and major
a majority of the more than 33,000 products are housed in a 1.72 million  ft² projects.
storage area. Through the use of state-of-the-art conveyor and control The patented heavy load length-cutting machines with more than 10 tons of
technology, more than 1,000 orders can be picked and shipped daily to load capacity are the largest of their type in Germany.
destinations around the world.
The new logistics center at the Taicang (China) production facility serves as a
Neuenhagen/Berlin is the central warehouse location for underground cable, product distribution hub for the Asian region, and offers incredible advantages,
medium-voltage cable, and other infrastructure cables. Storage capacities of particularly for servicing time-critical and volume-critical major projects.

Industrial cables
Our logistics center - Hemmingen/Stuttgart

· 40,500 Euro-pallet racks 16 aisles with 16 storage and


retrieval devices
· 35,900 bin locations in the automatic small parts warehouse
capacity: 1,000 bins per hour
· 670 storage spaces in the heavy load warehouse:
Reels to max. 8,820 lbs and 7 ft diameter
· 6,562 ft conveyor line for pallets
· Conveyer connection directly to the length-cutting machines
· Manual processes reduced to merely packing

Infrastructure cables
Our logistics center - Neuenhagen/Berlin

· 11,000 cable reels in stock


· Automatic processing of reels to 9 ft Ø and 10 t
· 10 rewinding machines
· Cut to length with state-of-the-art cutting tools
· 24 h delivery is possible

3
CONTROL CABLE | Flexible cables for fixed installation or occasional movements

Jacket material
Conductor Temperature
UV-resistant Color

Shielding
number range
Cat.
Voltage class without UL Standard
Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
300/ 500V JZ-500 no gray 2 - 100 -15°C to +80°C
flexible, numbered, VDE Reg. 30
no no 0.5 - 185 -40°C to +80°C
300/ 500V JZ-500 black yes black 2 - 25 -15°C to +80°C
flexible, numbered 32
yes no 0.5 - 35 -40°C to +80°C
300/ 500V JB-500 no gray 2 - 25 -15°C to +80C
flexible, color coded 42
no no 0.5 - 2.5 -40°C to +80°C
300/ 500V H05VV5-F (NYSLYö-JZ) no gray 2 - 65 -5°C to +70°C
flexible, numbered, extremely oil-resistant 35
no yes 0.5 - 2.5 -40°C to +70°C
300/ 500V JZ-500 orange no orange 2-5 -15°C to +80°C
without

33
shield

flexible, VDE-Reg., for interlocking purposes no no 1 - 2.5 -40°C to +80°C


300/ 500V H05VV-F no bw o. w 2 - 100 -5°C to +70°C
PVC jacketed cable 46
no no 0.5 - 185 -40°C to +70°C
300/ 500V OZ-BL no blue 2 - 41 -15°C to +80°C
intrinsically safe, flexible, numbered 105
no no 0.75 - 2.5 -40°C to +80°C
450/ 750V JB-750 no gray 2 - 11 -15°C to +80°C
flexible, color coded 43
no no 2.5 - 185 -40°C to +80°C
450/ 750V JB-750 yellow no yellow 3-5 -15°C to +80°C
flexible, for warning indication 44
no no 1.5 - 2.5 -40°C to +80°C
0,6/ 1KV JZ-600 yes black 2 - 100 -15°C to +80°C
flexible, numbered 40
yes no 0.5 - 185 -40°C to +80°C
300/ 500V F-CY-JZ no gray 2 - 100 -10°C to +80°C
PVC

flexible, numbered, Cu-shielded, VDE Reg. 50


no no 0.5 - 50 -40°C to +80°C
Halogen-free cables are marked in red / Bio-oil & microbe-resistant cables are marked in green / Intrinsically safe cables marked in blue

300/ 500V JZ -500 C black yes gray 2 - 100 -10°C to +80°C


flexible, numbered 52
yes no 0.5 - 50 -40°C to +80°C
300/ 500V H05VVC4V5-K (NYSLYCYÖ-JZ) no gray 2 - 65 -5°C to +70°C
flexible, numbered, oil-resistant, Cu-shielded 57
no yes 0.5 - 2.5 -40°C to +70°C
300/ 500V Y-CY-JZ no transp. 2 - 100 -15°C to +80°C
flexible, numbered, transparent, Cu-shielded 53
no no 0.5 - 150 -40°C to +80°C
300/ 500V Y-CY-JB no transp. 2-5 -15°C to +80°C
flexible, color coded, transparent, Cu-shielded 62
no no 0.5 - 185 -40°C to +80°C
shield

300/ 500V SY-JZ no transp. 2 - 100 -15°C to +80°C


with

flexible, numbered, with steel wire braiding 55


no no 0.5 - 150 -40°C to +80°C
300/ 500V SY-JB no transp. 2 - 12 -15°C to +80°C
flexible, color coded with steel wire braiding 64
no no 0.5 - 150 -40°C to +80°C
300/ 500V OZ-BL-CY no blue 2 - 41 -10°C to +80°C
intrinsically safe, flexible, numbered, Cu-shielded 106
no no 0.5 - 1.5 -40°C to +80°C
300/ 500V OB-BL-PAAR-CYr no blue 2 - 25 -10°C to +80°C
intrinsically safe, flexible, numbered, Cu-shielded 107
no no 0.5 - 0.75 -30°C to +80°C
Control cables

0,6/ 1kV JZ-600-Y-CY yes black 2 - 25 -15°C to +80°C


flexible, numbered, Cu-shielded 60
yes no 0.5 - 185 -40°C to +80°C
0,6/ 1kV TOPFLEX® 600-C-PVC no gray 4 -15°C to +80°C
Motor power supply, Cu-shielded 198
no no 1.5 - 120 -40°C to +80°C
300/ 500V JZ-500 PUR yes gray 2 - 42 -15°C to +80°C
Wear resistant, numbered 67
yes no 0.5 - 16 -40°C to +80°C
300/ 500V PURö-JZ yes gray 2 - 50 -20°C to +80°C
Wear resistant, coolant-resistant, extremely oil-resistant 68
yes no 0.5 - 95 -40°C to +80°C
300/ 500V PUR-ORANGE (also available as PUR-yellow, see page 71) yes orange 2-7 -15°C to +80°C
70
without

abrasion resistant, coolant-resistant


shield

yes yes 0.75 - 35 -40°C to +80°C


300/ 500V H05BQ-F / H07BQ-F yes orange 2-12 -40°C to +80°C
Oil-resistant PUR

abrasion resistant, wear resistant, tear and cut-resistant 72


yes no 0.75-240 -50°C to +90°C
300/ 500V UNIPUR yes n. Kw. 2 - 41 -40°C to +90°C
flexible at low temperature, wear resistant, robust, color coded 73
yes yes 0.5 - 16 -
450/ 750V PUR-750 yes orange 2 - 25 -40°C to +80°C
flexible at low temperature, color coded, halogen-free 75
yes yes 0.75 - 120 (short +100°C)
300/ 500V F-C-PURö-JZ yes gray 2 - 50 -20°C to +80°C
Notch resistant, numbered, coolant-resistant 78
yes no 0.5 - 6 -40°C to +80°C
300/ 500V YÖ-C-PURÖ-JZ yes gray 2 - 50 -20°C to +80°C
shield
with

Notch resistant, numbered, coolant-resistant 80


yes yes 0.5 - 120 -40°C to +80°C
300/ 500V UNIPUR-CP yes n. Kw. 2 - 41 -40°C to +90°C
flexible at low temperature, wear resistant, robust, color coded, Cu-shieldded 82
yes yes 0.5 - 16 -
300/ 500V JZ-500 HMH no gray 2 - 65 -15°C to +70°C
flexible, numbered, extremely fire resistant, oil-resistant, halogen-free 86
no yes 0.5 - 120 -40°C to +70°C
300/ 500V MEGAFLEX 500 ®
yes gray 2 - 65 -30°C to +80°C
flexible, halogen-free, flame retardant, oil-resistant 88
yes no 0.5 - 150 -40°C to +80°C
without
shield

450/ 750V H07 ZZ-F no black 1 - 36 -5°C to +70°C


Halogen-free, cross-linked jacketed cable 90
no no 1.5 - 300 -20°C to +70°C
FRNC Halogen-free

450/ 750V JB-750 HMH no gray 3-5 -15°C to +70°C


flexible, color-coded, halogen-free, extremely fire resistant, oil-resistant 93
no yes 1.5 - 120 -40°C to +70°C
0,6/ 1kV JZ-600 HMH yes black 2 - 25 -15°C to +70°C
flexible, numbered, extremely fire resistant, oil-resistant, halogen-free 91
yes yes 0.5 - 120 -40°C to +70°C
300/ 500V JZ-500 HMH-C no gray 2 - 25 -15°C to +70°C
flexible, numbered, oil-resistant, halogen-free, Cu-shielded, extremely fire resistant 96
no yes 0.5 - 120 -40°C to +70°C
300/ 500V MEGAFLEX® 500-C yes gray 2 - 25 -30°C to +80°C
98
shield

flexible, halogen-free, flame retardant, oil-resistant, Cu-shielded


with

yes no 0.5 - 150 -40°C to +80°C


450/ 750V JB-750 HMH-C no gray 3-5 -15°C to +70°C
flexible, color-coded, oil-resistant, halogen-free, Cu-shielded, extremely fire resistant 102
no yes 1.5 - 120 -40°C to +70°C
0,6/ 1kV JZ-600 HMH-C yes black 3 - 25 -15°C to +70°C
flexible, numbered, oil-resistant, halogen-free, Cu-shielded, extremely fire resistant 100
yes yes 0.5 - 150 -40°C to +70°C
300/ 500V KOMPOFLEX JZ-500
with without

yes black 2 - 61 -30°C to +90°C


Oil-resistant

shield shield

halogen-free, numbered, microbe-resistant 112


TPE-O

yes yes 0.5 - 50 -40°C to +100°C


300/ 500V KOMPOFLEX JZ-500-C yes black 2 - 61 -30°C to +90°C
halogen-free, numbered, Cu-shield 113
yes yes 0.5 - 50 -40°C to +100°C
* Extremely oil resistant: Please contact us first for special applications.
4
Flexible cables for fixed installation or occasional movements

Conductor Temperature
UV-resistant Color
number range
Voltage Cat.
According to UL/CSA NFPA
class Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
600V JZ-602 no gray 2 - 41 -5°C to +90°C
flexible, numbered, two approval, oil-resistant no 356
no yes 0.5 - 120 -40°C to +90°C
600V JZ-603 no gray 2 - 61 -5°C to +90°C
flexible, numbered, MULTI approval, oil-resistant no 358
no yes 0.5 - 2.5 -40°C to +90°C
0,6/ 1kV JZ-600 UL/CSA yes (bw) bw / gr 2 - 25 -5°C to +80°C
flexible, numbered, two approval no 362
yes (bw) no 0.5 - 25 -40°C to +80°C
0,6/ 1kV HELUWIND WK 103w-T yes black 1 - 50 -35°C to +90°C
UV-resistant, Single-/Multiconductor no 808
yes no 0.34 - 400 -40°C to +90°C
0,6/ 1kV HELUWIND WK 103k-T yes black 1 - 50 -40°C to +80°C
UV-resistant, Single-/Multiconductor no 809
yes no 0.34 - 400 -40°C to +80°C
600V TRAYCONTROL 500 no gray 2 - 61 -5°C to +90°C
flexible, numbered, oil-resistant TC-ER, PLTC-ER, ITC-ER yes 359
no yes AWG20 - 4/0 -40°C to +90°C
600V JZ 604 TC TRAY CABLE yes black 2 - 25 -5°C to +90°C
flexible, numbered, exposed run yes 364
yes yes AWG18 - 4/0 -25°C to 90°C
600V TRAYCONTROL 600 yes black 2 - 61 -
flexible, numbered, oil-resistant, exposed run yes 366
yes yes AWG18 - 500KCMIL -40°C to +90°C
300V H05VV-F/SIT no bw, gr, wh 2-5 -5°C to +90°C
flexible, color coded no 368
no no AWG17 - 11 -40°C to +60°C

600V JZ-602-CY no gray 2 - 41 -5°C to +90°C


flexible, numbered, shielded, two approval, oil-resistant, inner jacket no 373
no yes 0.5 - 120 -40°C to +90°C
600V JZ-603-CY no gray 2 - 61 -5°C to +90°C
flexible, numbered, shielded, MULTI approval, inner jacket no 375
no yes 0.5 - 2.5 -40°C to +90°C
0,6/ 1kV JZ-600-Y-CY UL/CSA yes (bw) bw o. gr 2 - 25 -5°C to +80°C
flexible, numbered, shielded, two approval, oil-resistant, inner jacket no 378
yes (bw) no 0.5 - 25 -40°C to +80°C
0,6/ 1kV HELUWIND WK 103w EMV D-T yes black 1 - 50 -35°C to +90°C
UV-resistant, Single-/Multiconductor no 808
yes yes 0.34 - 300 -40°C to +90°C
0,6/ 1kV HELUWIND WK 103k EMV D-T yes black 1 - 50 -40°C to +80°C
UV-resistant, Single-/Multiconductor no 809
yes yes 0.34 - 300 -40°C to +80°C
600V TRAYCONTROL 500-C no gray 2 - 735 -5°C to +90°C
flexible, numbered, oil-resistant, Cu-shielded, exposed run TC-ER, PLTC-ER, ITC-ER yes 376
no yes AWG20 - 2 -40°C to +90°C
600V JZ 604-FCY TC TRAY CABLE yes black 2 - 61 -5°C to +90°C
flexible, numbered, exposed run yes 380
yes yes AWG18 - 8 -25°C to +90°C
600V JZ 604-YCY TC TRAY CABLE yes black 3-7 -5°C to +90°C
flexible, numbered, exposed run, inner jacket yes 381
yes yes AWG6 - 4/0 -25°C to +90°C
600V TRAYCONTROL 600-C yes black 3 - 25 -
flexible, numbered, oil-resistant, exposed run yes 382
yes yes AWG18 - 2 -40°C to +90°C

600V JZ-602-PUR yes gray 2 - 41 -5°C to +80°C


flexible, numbered, two approval, oil-resistant no 384
yes yes 0.5 - 25 -40°C to +80°C
0,6/ 1kV JZ-600 PUR yes bw o. gr 2 - 25 -5°C to +80°C
flexible, numbered, wear resistant, coolant-resistant, oil-resistant no 387
yes yes 0.5 - 25 -40°C to +80°C
0,6/ 1kV HELUWIND WK 135-T yes black 1 - 32 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 810
yes yes 0.34 - 400 -40°C to +90°C
0,6/ 1kV HELUWIND WK 137-T FT4 yes black 3 - 18 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C

600V JZ-602-C-PUR yes gray 2 - 41 -5°C to +80°C


flexible, numbered, Cu-shielded, two approval, oil-resistant, inner sheat no 389
yes yes 0.5 - 120 -40°C to +80°C
0,6/ 1KV JZ-600-YC-PUR yes bw o. gr 2 - 25 -5°C to +80°C
flexible, numbered, notch resistant, coolant-resistant, oil-resistant, Cu-shielded no 390
yes yes 0.5 - 16 -40°C to +80°C
0,6/ 1KV HELUWIND WK 135 D-EMV T yes black 1 - 32 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 810
yes yes 0.34 - 300 -40°C to +90°C
600V MEGAFLEX® 500 yes gray 2 - 65 -30°C to +80°C
Halogen-free, flame-retardant, oil resistant, UV resistant, numbered no 394
yes yes 0.5 - 150 -40°C to +80°C
0,6/ 1kV MEGAFLEX 600 ®
yes black 2 - 65 -30°C to +80°C
flexible, numbered, flame retardant, oil-resistant, UV-resistant no 396
yes yes 0.5 - 150 -40°C to +80°C
0,6/ 1kV HELUWIND WK 137-T FT4 yes black 3 - 18 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C

600V MEGAFLEX® 500-C yes gray 2 - 25 -30°C to +80°C


Halogen-free, flame-retardant, oil resistant, UV resistant, numbered no 398
yes yes 0.5 - 150 -40°C to +80°C
0,6/ 1kV MEGAFLEX® 600-C yes black 2 - 25 -30°C to +80°C
flexible, numbered, flame retardant, oil-resistant, UV-resistant, Cu-shielded no 400
yes yes 0.5 - 10 -40°C to +80°C
0,6/ 1kV HELUWIND WK 137 D-EMV T yes black 3 - 18 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C

600V TRAYCONTROL 670 HDP no orange 4 -


oil-resistant, exposed run (TC-ER) yes 392
no yes 1 - 35 -40°C to +105°C
600V TRAYCONTROL 670-C HDP no orange 4 -
oil-resistant, exposed run (TC-ER) yes 392
no yes 1 - 35 -40°C to +105°C
* Extremely oil resistant: Please contact us first for special applications.
5
DATA CABLES | Flexible cables for fixed installation or occasional movements
Conductor
Voltage number/ Temperature
UV-resistant Color

Shielding
material
Jacket class Number of range
Cat.
(Peak without UL Standard pairs
page
operating Flexing
Laying Increased oil Cross
voltage)
outside resistance* section Fixed installation
300/ 500V TRONIC (LiYY) no gray 2 - 100 -5°C to +80°C
flexible, color code according to DIN 47100 124
no no 0.14 - 1.5 -40°C to +80°C
300/ 500V PAAR-TRONIC no gray 1 - 55 -5°C to +80°C
twisted pairs, flexible, color code according to DIN 47100 126
no no 0.14 - 0.75 -30°C to +80°C
without
shield

350V SENSORFLEX no gb/or 3-5 -5°C to +80°C


Senor actuator cable, color coded 128
no no 0.25 - 0.34 -30°C to +80°C
300/500V VERTEILERFLEX no gray/bw 3-5 -5°C to +80°C
for senor actuator cable, color coded 129
no no 0.25 - 0.34 -30°C to +80°C

250V PAAR-TRONIC-Li-2YCYv no black 2 - 10 -5°C to +70°C


PE-insulated, low capacitance, Termi-Point®, color-coded 138
yes no 0.22 - 1 -30°C to +80°C
PVC

250V PAAR-TRONIC-Li-2YCY no gray 2 - 10 -5°C to +70°C


PE-insulated, low capacitance, Termi-Point®, color-coded 139
no no 0.2 -30°C to +80°C
Halogen-free cables are marked in red

350V LifYCY no gray 2 - 32 -5°C to +70°C


Highly flexible, in pairs, fully shielded 140
no no 0.22 - 0.5 -40°C to +70°C
shield
Data cables

300/ 500V TRONIC-CY (LiY-CY) no gray 1 - 100 -5°C to +80°C


with

flexible, color code according to DIN 47100, Cu-shielded 131


no no 0.14 - 1.5 -40°C to +80°C
300/ 500V PAAR-TRONIC-CY no gray 1 - 61 -5°C to +80°C
twisted pairs, flexible, color code according to DIN 47100, Cu-shielded 133
no no 0.14 - 1.5 -30°C to +80°C
300/ 500V PAAR-CY-OZ no gray 2 - 25 -5°C to +80°C
twisted pairs, flexible, numbered, Cu-shielded 135
no no 1 - 1.5 -40°C to +80°C
300/ 500V PAAR-TRONIC-CY-CY (LiYCY-CY) no gray 2 - 48 -5°C to +80°C
twisted pairs, flexible, numbered, Cu-shielded, PVC jacket overall CY pairs 136
no no 0.14 - 0.5 -40°C to +80°C
without
shield
Oil-resistant PUR

350V DATAPUR-C yes gray 2 - 25 -5°C to +80°C


with shield

flexible, color code according to DIN 47100, Cu-shielded 144


yes yes 0.14 - 0.5 -40°C to +80°C

300/ 500V DATAFLAMM


without

no gray 2 - 50 +5°C to +70°C


FRNC Halogen-free

shield

Halogen-free 130
no no 0.14 - 0.75 -40°C to +70°C
350V DATAFLAMM-C no gray 2 - 40 +5°C to +70°C
with shield

Halogen-free, Cu-shielded 145


no no 0.14 - 0.75 -40°C to +70°C
350V DATAFLAMM-C PAAR no gray 2 - 18 +5°C to +70°C
Halogen-free, Cu-shielded 146
no no 0.14 - 0.75 -40°C to +70°C

SINGLE CONDUCTORS | Flexible cables for fixed installation or occasional movements


Conductor Temperature
UV-resistant Color
Shielding
material

number range
Jacket

Voltage Cat.
without UL Standard
class Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
300/ 500V H05V-K no different 1 -5°C to +70°C
PVC conductor, fine stranded 289
no no 0.5 - 1 -30°C to +80°C
450/ 750V H07V-K/ (H)07V-K no different 1 -5°C to +70°C
PVC conductor, fine stranded 291
no no 1.5 - 240 -30°C to + 80°C
H05V-K 300/ 500V no different 1 -5°C to +70°C
(H)07V-K 2-colored 450/750V 293
no no 0.5 - 240 -30°C to +80°C
H05V-K Fassware 300/500V no different 1 -5°C to +70°C
H07V-K Fassware 450/750V 296
no no 0.5 - 6 -30°C to +80°C
without
shield

H05V-U / (H)05V-U / (H)07V-U no different 1 -5°C to +70°C


05= 300/ 500V, 07= 450/750V 294
no no 0.5 - 10 -30°C to +80°C
PVC

450/ 750V H07V-R no different 1 -5°C to +70°C


PVC single-conductors multi-wire 295
no no 16 - 240 -30°C to +80°C
Halogen-free cables are marked in red

300/ 500V H05V2-K/LiYW no different 0.5 - 1 +5°C to +90°C


Single conductors

PVC single-conductors, 90°C, heat-resistant 303


no different 0.14 - 0.5 -10°C to +105°C
450/ 750V H07V2-K no bw 1 +5°C to +90°C
PVC single-conductors, 90°C, heat-resistant 304
no no 1.5 - 240 -
shield
without with

1kV PUR-SINGLE ConductorS


yes different 1 -40°C to +80°C
Oil-resistant PUR

Shield

Cold resistant, halogen-free 299


yes no 0.5 - 1.5 -
with shield

300/ 500V HELUTERM 145 yes different 1 -


305
without

450/ 750V flexible, cross-linked, halogen-free,


shield

yes no 0.25 - 240 -55°C to +145°C


FRNC

shield
with

* Extremely oil resistant: Please contact us first for special applications.

6
Flexible cables for fixed installation or occasional movements

Conductor
number/ Temperature
UV-resistant Color
Number of range
Voltage Cat.
According to UL/CSA NFPA pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation
300V Control cable UL (LiYY) no bw o. gr 2 - 30 -10°C to +80°C
Style 2464/300V (80°C) no 403
no no 0.14 - 1.3 -20°C to +80°C
600V Control cable UL (LiYY) no bw o. gr 2 - 36 -10°C to +105°C
Style 2516/600V (105°C) no 404
no no 2.08 - 3.2 -20°C to +105°C
300V Control cable UL (LiYY-TP) no bw o. gr 1 - 25 -10°C to +80°C
twisted pairs, Style 2464/300V (80°C) no 407
no no 0.14 - 0.56 -20°C to +80°C
300V TRAYCONTROL 300 no gray 2 - 50 -25°C to +105°C
flexible, oil-resistant, NPFA79 yes 405
no yes 0.08 - 1.5 -
300V TRAYCONTROL 300 TP no gray 1 - 250 -25°C to +105°C
twisted pairs, flexible, oil-resistant, NPFA79 yes 409
no yes 0.14 - 1.0 -
300V Control cable UL (LiYCY) no bw o. gr 2 - 30 -10°C to +80°C
Style 2464/300V (80°C), Cu-shielded no 413
no no 0.14 - 1.3 -20°C to +80°C
300V Control cable UL (LiYCY) no bw o. gr 1 - 25 -10°C to +80°C
twisted pairs, Cu-shielded, Style 2464/300V (80°C) no 418
no no 0.14 - 0.56 -20°C to +80°C
300V TRAYCONTROL 300-C no gray 2 - 50 -
flexible, Cu-shielded, oil-resistant, NPFA79 yes 416
no yes 0.08 - 1.5 -25°C to +105°C
300V TRAYCONTROL 300-C TP no gray 1 - 25 -
twisted pairs, flexible, Cu-shielded, oil-resistant, NPFA79 yes 420
no yes 0.14 - 1.0 -25°C to +105°C
600V Control cable UL (LiYCY) no bw o. gr 2 - 30 -10°C to +105°C
Style 2516/600V (105°C), Cu-shielded no 415
no no 2.08 - 3.2 -20°C to +105°C

0,6/ 1kV HELUWIND WK 135-T yes black 1 - 32 -40°C to +90°C


UV-resistant, Single-/Multiconductor 90°C no 810
yes yes 0.34 - 400 -40°C to +90°C
0,6/ 1KV HELUWIND WK 135 D-EMV T yes black 1 - 32 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 810
yes yes 0.34 - 300 -40°C to +90°C
0,6/ 1kV HELUWIND WK 137 D-EMV T yes black 3 - 18 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C
0,6/ 1kV HELUWIND WK 137-T FT4 yes black 3 - 18 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C

0,6/ 1kV HELUWIND WK 137 D-EMV T yes black 3 - 18 -40°C to +90°C


UV-resistant, Single-/Multiconductor 90°C no 811
yes yes 0.75 - 35 -40°C to +90°C

Conductor Temperature
UV-resistant Color
number range
Voltage Cat.
According to UL/CSA NFPA
class Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
300V UL Style 1007, CSA TR 64 no different 1 -5°C to +80°C
PVC single-conductors, 80°C, tinned conductor no 485
no no 0.13 - 5.26 -30°C to +90°C
300V UL Style 1569, CSA TR 64 no different 1 -5°C to +105°C
PVC single-conductors, 105°C no 486
no no 0.13 - 5.26 -30°C to +105°C
600V UL Style 1015 no different 1 -5°C to +105°C
PVC single-conductors no 487
no no 0.21 - 254 -30°C to +105°C
600V THREENORM no different 1 +5°C to 70°C
PVC single conductor, UL Style 1013 and CSA 600V no 488
no no 0.5 - 150 -10°C to +70°C
600V SINGLE 600 -J/-O yes bw 1 -5°C to +90°C
Special single-conductor cables, double insulated no 498
yes no 6 - 240 -40°C to +90°C
0,6/ 1kV HELUWIND WK 103w-T yes black 1 -35°C to +90°C
UV-resistant, Single-/Multiconductor no 808
yes no 0.34 - 400 -40°C to +90°C
0,6/ 1kV HELUWIND WK 103k-T yes black 1 -40°C to +80°C
UV-resistant, Single-/Multiconductor no 809
yes no 0.34 - 400 -40°C to +80°C
600V FIVENORM HAR-UL-CSA-AWM-MTW no different 1 +5°C to +90°C
PVC-single conductor 600V, 105°C yes 490
no no 0.5 - 1 -40°C to +105°C
600V THHN no different 1 +90°C dry NEC
90°C, PVC + Nylon single conductor yes 493
no no 2.08 - 507 -
600V SINGLE 600-CY -J/-O yes bw 1 -5°C to +90°C
Special single-conductor cables, shielded, double insulated no 499
yes no 6 - 240 -40°C to +90°C
0,6/ 1kV HELUWIND WK 135-T
yes black 1 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 810
yes yes 0.34 - 400 -40°C to +90°C

300V HELUTERM® 145 yes different 1 -35°C to +120°C


Conductor insulation, flexible, cross-linked, halogen-free, no 495
yes no AWG 24 -10 -55°C to +125°C
600 V HELUTERM 145 ®
yes different. 1 -35°C to +120°C
Conductor insulation, flexible, cross-linked, halogen-free, no 496
yes no 0.25 - 50 -55°C to +125°C
0,6/ 1KV HELUWIND WK 135 D-EMV T yes black 1 -40°C to +90°C
UV-resistant, Single-/Multiconductor 90°C no 810
no yes 0.34 - 300 -40°C to +90°C
* Extremely oil resistant: Please contact us first for special applications.

7
MOTOR AND SERVO CABLES | Flexible cables for fixed installation or occasional movements
Conductor
number/ Temperature
UV-resistant Color

Shielding
material
Jacket Number of range
Voltage Cat.
without UL Standard pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation
0,6/ 1kV TOPFLEX® 600-PVC
without

no gray 4 -15°C to +80°C


shield

Motor cable without pair, flexible, numbered 197


no no 1.5 - 120 -40°C to +80°C
0,6/ 1kV TOPFLEX 600-C-PVC
®
no gray 4 -15°C to +80°C
Motor cable without pair, flexible, Cu-shielded, numbered 198
no no 1.5 - 120 -40°C to +80°C
0,6/ 1kV TOPFLEX®-EMV-2YSLCYK-J no transp. 4 -5°C to +70°C
Motor cables for power supply connections to frequency converters 204
no no 1,5 - 185 -40°C to +70°C
0,6/ 1kV TOPFLEX®-EMV-3 PLUS 2YSLCY-J no transp. 3 -5°C to +70°C
Motor cables for power supply connections to frequency converters 205
no no 1.5 - 240 -40°C to +70°C
Motor and servo cables

0,6/ 1kV TOPFLEX®-EMV-UV-2YSLCK-J yes black 4 -5°C to +70°C


Motor cables for power supply connections to frequency converters 206
yes no 1,5 - 185 -40°C to +70°C
0,6/ 1kV TOPFLEX® -EMV-UV-3 PLUS 2YSLCYK-J yes black 3 -5°C to +70°C
Motor-supply cable with control conductors 207
yes no 1.5 - 240 -40°C to +70°C
with shield
PVC

0,6/ 1kV TOPFLEX® -EMV-UV-2XSLCYK-J yes black 4 -5°C to +90°C


Motor-supply cable with control conductors 209
yes no 1,5 - 185 -40°C to +90°C
0,6/ 1kV TOPFLEX® -EMV-UV-3 PLUS 2XSLCYK-J yes black 3 -5°C to +90°C
Motor-supply cable with control conductors 211
yes no 1.5 - 240 -40°C to +90°C
0,6/ 1kV TOPFLEX® -EMV-UV-2XSLCH-J no black 4 -5°C to +90°C
Motor-supply cable with control conductors 213
no no 1,5 - 185 -40°C to +90°C
0,6/ 1kV TOPFLEX® - EMV-UV-3 PLUS 2XSLCH-J no black 3 -5°C to +90°C
Motor-supply cable with control conductors 215
no no 1.5 - 240 -40°C to +90°C
0,6/ 1kV TOPFLEX® MOTOR 109 yes orange 3-7 -5°C to +70°C
Low capacitance motor power supply cable, increased load rating 217
yes no 1.5 - 25 -40°C to +80°C
with without
Oil-resistant

shield shield
PUR

0,6/ 1kV TOPFLEX® MOTOR 109 yes orange 3-7 -5°C to +70°C
Low capacitance motor power supply cable, increased load rating 217
yes no 1.5 - 25 -40°C to +80°C

FEEDBACK CABLES | Flexible cables for fixed installation or occasional movements


Conductor
number/ Temperature
UV-resistant Color
Shielding
material

Number of range
Jacket

Voltage Cat.
without UL Standard pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation
with without with without
shield shield shield shield
Feedback cables

PVC

300V Feedback cables PVC no gray - -5°C to +70°C


202
no no - -30°C to +80°C
Oil-resistant
PUR

300V Feedback cables PUR no gray - -30°C to +80°C


203
no no - -40°C to +80°C

* Extremely oil resistant: Please contact us first for special applications.

Energy cable tracks

Energy cable tracks

·O
 pen chains
·C
 losed chains
· Accessories
· Installation instructions
· S election tables

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

8
Flexible cables for fixed installation or occasional movements

Conductor
number/ Temperature
UV-resistant Color
Number of range
Voltage Cat.
According to UL/CSA NFPA pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation

0,6/ 1kV TOPSERV® 108 PVC acc. to Siemens 6FX5008 no orange 4 -0°C to +60°C
Motor cable without pair, flexible, Cu-shielded, numbered no 465
no yes 1.5 - 50 -20°C to +80°C
0,6/ 1kV TOPSERV 112 PVC acc.to such as Siemens 6FX5008, Lenze
®
no orange 4 0°C to +60°C
Servo cable with single pair, flexible, Cu-shielded no 465
no yes 1.5 - 50 -20°C to +80°C
0,6/ 1kV TOPSERV® 119 PVC similar Indramat INK no orange 4 -0°C to +60°C
Servo cable with two pairs, flexible, Cu-shielded no 465
no yes 1.5 - 50 -20°C to +80°C
0,6/ 1kV TOPFLEX® 600 VFD yes or o. bw 4 -
Motor cable without pair, flexible yes 458
yes yes 1,5 - 35 -25°C to +90°C
0,6/ 1kV TOPFLEX® 650 VFD yes or o. bw 4 -
Servo cable with single pair yes 459
yes yes 1,5 - 35 -25°C to +105°C
1kV TOPFLEX®-EMV-UV-2YSLCYK yes black 4 -5°C to +80°C
Motor cables for power supply connections to frequency converters no 453
yes no 1,5 - 185 -40°C to +80°C
1kV TOPFLEX®-EMV-UV-3 PLUS 2YSLCYK-J yes black 3 -5°C to +80°C
Motor cables for power supply connections to frequency converters no 455
yes no 1.5 - 240 -40°C to +80°C
1kV TOPFLEX -EMV-UV-2YSLAC11Y-J UL/CSA
®
yes black 4 -5°C to +80°C
Motor cables for power supply connections to frequency converters no 461
yes no 1,5 - 185 -40°C to +80°C

1kV TOPFLEX® 1000 VFD yes black 4 -5°C to +80°C


Motor-supply cable with control conductors yes 460
yes no 1,5 - 185 -40°C to +80°C
1kV TOPSERV® Hybrid yes orange 8 -30°C to +80°C
Hybrid cable for SICK HIPERFACE DSL motor-feedback systems no 474
yes no 0.5 - 16 -40°C to +80°C

Siemens 6FX5008…, Siemens 6FX8008Plus… are registered trademarks of SIEMENS AG and are intended exclusively for comparative purposes. INDRAMAT INK… are registered trademarks of BOSCH
REXROTH AG and are intended exclusively for comparative purposes. LENZE … are registered trademarks of LENZE AG and are intended exclusively for comparative purposes.

Conductor
number/ Temperature
UV-resistant Color
Number of range
Voltage Cat.
According to UL/CSA NFPA pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation

30V + 300V TOPGEBER 511 PVC no gn o. or - -0°C to +60°C


acc. to such as Siemens 6FX5008, Lenze, similar to Indramat no 467
no yes - -20°C to +80°C

30V + 300V TOPGEBER 512 PVC yes gn - -30°C to +80°C


acc. to such as Siemens 6FX5008, Lenze, similar to Indramat no 470
yes no - -40°C to +80°C

Siemens 6FX5008…, Siemens 6FX8008Plus… are registered trademarks of SIEMENS AG and are intended exclusively for comparative purposes. INDRAMAT INK… are registered trademarks of BOSCH
REXROTH AG and are intended exclusively for comparative purposes. LENZE … are registered trademarks of LENZE AG and are intended exclusively for comparative purposes.
* Extremely oil resistant: Please contact us first for special applications.
Bundling, binding, and fastening

Bundling, binding, and fastening

· Plastic helix
· Cable tie
· Velcro fastener
· Mounting base

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

9
PROFINET / INDUSTRIAL ETHERNET | Flexible cables for fixed installation or occasional movements
UV- Temperature
Part number
Category

material
resistant range

Jacket
Frequency Cat.
without UL Standard
range Increased page
Laying Outer-Ø Flame
oil
outside ca. resistant
resistance*
PVC

Cables are only available with UL/CSA standard; shown on the opposite column, right page

100 MHz HELUKAT® 100IND, SF/UTP no 805699 -30°C to +80°C


AUR
2x2xAWG24/1 no no 5,6 mm IEC 60332-1-2
CAT 5e

100 MHz HELUKAT 100IND, SF/UTP


® no 805701 -5°C to +60°C
INDUSTRIAL ETHERNET

AUR
2x2xAWG26/7
Halogen-free cables are marked in red

no no 5,6 mm IEC 60332-1-2


FRNC

Cables are only available with UL/CSA standard; shown on the opposite column, right page

100 MHz HELUKAT® 100IND PROFInet A, robust yes 801194 -40°C to +80°C
2x2xAWG22/1, Fast Connect 699
no yes 6,5 mm IEC 60332-1-2
100 MHz HELUKAT 200IND S-FTP, Robustflex
®
no 800068 -40°C to +80°C
PUR

4x2xAWG26/7 692
no yes 5,8 mm IEC 60332-1-2
100 MHz HELUKAT® 100IND PROFInet A, radiation-resistant yes 801195 -40°C to +80°C
2x2xAWG22/7, Fast Connect 700
no yes 6,5 mm IEC 60332-1-2
CAT 6 / CAT 6A

PVC

Cables are only available with UL/CSA standard; shown on the opposite column, right page

600 MHz HELUKAT® 600IND S/STP, robust no 801197 -40°C to +80°C


PUR FRNC PVC
CAT 7 /CAT7A/

4x2xAWG23/1 687
no yes 7,8 mm IEC 60332-1-2
CAT 7e

600 MHz HELUKAT® 600IND S/FTP, SHIPLINE no 803382 -20°C to +75°C


4x2xAWG24/7 688
no no 9,1 mm IEC 60332-3

Cables are only available with UL/CSA standard; shown on the opposite column, right page

BUS CABLES | Flexible cables for fixed installation or occasional movements


UV- Temperature
BUS system

Installation

Part number
material

resistant range
Jacket

range

Cat.
Impedance without UL Standard Increased
Laying Outer-Ø Flame page
oil
outside ca. resistant
resistance*
150 OHM Profibus high temperature +105°C 805705 -40°C to +105°C
1x2x0,64 mm AUR
7,8 mm IEC 60332-1-2
Indoor
PVC
Halogen-free cables are marked in red

150 OHM Profibus L2 1x2x0,64 mm PUR teal no 81186 -40°C to +70°C


resistant

Indoor
PUR
Oil-

706
no yes 8,0 mm IEC 60332-1-2
Profibus 150 OHM

150 OHM Profibus L2 1x2x0,64 mm Shipline violet no 802178 -25°C to +80°C


711
no no 8,0 mm IEC 60332-1-2
150 OHM Profibus high temperature +200°C
Indoor

no 805706 -50°C to +200°C


FRNC

1x2xAWG23/1 AUR
no no 8,3 mm IEC 60332-1-2
150 OHM Profibus Profibus, fixed installation, PH120 no 805695 -20°C to +70°C
1x2xAWG23/1 AUR
no no 8,3 mm VDE 0482-332-1-2
150 OHM Profibus L2 1x2x0,64 mm PE black yes 80792 -40°C to +70°C
Outdoor 706
yes no 8,0 mm -
150 OHM Profibus L2 1x2x0,64 mm PVC/PE black yes 82824 -40°C to +80°C
direct burial 707
yes no 10,0 mm -
PE

150 OHM Profibus L2 1x2x0,64 mm PVC/PE black yes 802177 -40°C to +80°C
Direct burial armoured 707
yes no 10,6 mm -
150 OHM Profibus L1 1x2x0,64 mm PE black yes 81904 -20°C to +70°C
Outdoor, Fast Connect 715
yes no 9,6 mm -
150 OHM Profibus L2 1x2x0,64 mm high temperature +180°C violet no 802179 -50°C to +180°C
FEP

711
yes yes 7,2 mm IEC 60332-3

100 OHM Profibus PA armoured 1x2x1,0/ 2,55 mm PVC/PVC black yes 802181 -20°C to +70°C
715
yes no 10,2 mm IEC 60332-1-2
Profibus PA
100 OHM

100 OHM Profibus PA armoured 1x2x1,0/2,55 mm PVC/PVC blue EX no 802180 -20°C to +70°C
715
Indoor

no no 10,2 mm IEC 60332-1-2


PVC

* Extremely oil resistant: Please contact us first for special applications.


AUR = A vailable upon request, or refer to the Data, Network and BUS Technology catalog

10
Flexible cables for fixed installation or occasional movements

UV- Temperature
Part number
resistant range
Frequency Cat.
According to UL/CSA NFPA
range page
Laying Increased Outer-Ø Flame
outside oil resistance* ca. resistant
100 MHz HELUKAT® 100IND PROFInet A FRNC, fixed laying CMG no 805653 -40°C to +80°C
2x2xAWG22/1, Fast Connect yes 699
no no 6,5 mm IEC60332-3
100 MHz HELUKAT® 100IND PROFInet B, flexible CMG yes 800654 -40°C to +70°C
2x2xAWG22/7, Fast Connect yes 703
no yes 6,5 mm IEC 60332-1-2
100 MHz HELUKAT 100IND PROFInet B, Festoon
®
yes 803295 -10°C to +80°C
2x2xAWG22/7, Fast Connect yes 702
no no 6,5 mm IEC60332-3
100 MHz HMCB200 Industrial Ethernet PVC green no 802471 -20°C to +80°C
UL Style 2502 no 724
no no 6,8 mm IEC60332-1
100 MHz HMCB500S Industrial Ethernet PVC green no 803672 0°C to +60°C
UL Style 2502 no 725
no no 6,95 mm IEC60332-1
100 MHz HELUKAT® 100IND PROFInet A FRNC, fixed laying CMG no 805653 -40°C to +80°C
2x2xAWG22/1, Fast Connect yes 699
no no 6,5 mm IEC60332-3
100 MHz HELUKAT 100IND PROFInet B, flexible CMG
®
yes 800654 -40°C to +70°C
2x2xAWG22/7, Fast Connect yes 703
no yes 6,5 mm IEC 60332-1-2
100 MHz HELUKAT® 100IND PROFInet B, hybrid UL style 21282 yes 801651 -40°C to +70°C
2x2xAWG22/7+4x1,5 no 701
no yes 10,3 mm IEC 60332-1-2
100 MHz HELUKAT® 100IND PROFInet B, WINDKRAFT 105°C yes 802293 -40°C to +105°C
yes 693
2x2xAWG22/7, Fast Connect no no 6,5 mm IEC60332-3
100 MHz HELUKAT® 100IND PROFInet B, Shipline yes 802185 -40°C to +70°C
2x2xAWG22/7, Fast Connect yes 702
no no 6,5 mm IEC60332-3

Cables are only available without UL/CSA standard; shown on the opposite column, left page

250 MHz HELUKAT® 250IND SF/UTP, AWM no 805681 -40°C to +80°C


4x2xAWG24/1 no AUR
no no 8,0 mm IEC 60332-3
250 MHz HELUKAT® 250IND SF/UTP, CMG no 805655 -40°C to +80°C
4x2xAWG24/1 yes AUR
no no 8,0 mm IEC 60332-3
500 MHz HELUKAT 500IND S/FTP, 10GIG CM
®
no 803693 -40°C to +70°C
4x2xAWG22/1 yes 690
no yes 9,6 mm IEC 60332-1-2

Cables are only available without UL/CSA standard; shown on the opposite column, left page

Cables are only available without UL/CSA standard; shown on the opposite column, left page

600 MHz HELUKAT® 600IND S/FTP, Robustflex UL style 20963 no 802184 -40°C to +80°C
no 689
4x2xAWG26/7 no yes 6,4 mm IEC 60332-1-2

UV- Temperature
Part number
resistant range
Impedance acc. to UL/CSA Cat.
NFPA
(please note exceptions) Laying Increased Outer-Ø Flame page
outside oil resistance* ca. resistant
150 OHM Profibus L2 1x2x0,64 mm PVC no 80384 -40°C to +70°C
gray CMX yes 705
no no 7,8 mm IEC 60332-1-2
150 OHM Profibus L2 1x2x0,64 mm PVC no 81448 -40°C to +70°C
violet CMX yes 705
no no 7,8 mm IEC 60332-1-2
150 OHM Profibus SK 1x2x0,64 mm VC violet CMG yes 81903 -40°C to +80°C
Fast Connect yes 717
no no 8,0 mm IEC 60332-3
150 OHM Profibus L2/FIP 7-wire 1x2x0,64 mm PVC violet UL 2571 no 800648 -20°C to +80°C
continuous movements, no CSA! no 708
no no 7,8 mm EN 50265-2-1
150 OHM Profibus SK 1x2x0,64 mm PUR violet UL style 20236 yes 81905 -40°C to +70°C
Fast Connect no 718
no yes 8,0 mm IEC 60332-1-2
150 OHM Profibus SK 1x2x0,64 mm FRNC violet CM no 81501 -25°C to +70°C
Fast Connect yes 718
no no 8,0 mm EN 50265-2-1

Cables are only available without UL/CSA standard; shown on the opposite column, left page

Cables are only available without UL/CSA standard; shown on the opposite column, left page

100 OHM Profibus PA 1x2x1,0/ 2,55 mm PVC black UL Style 2571, no 82836 -30°C to +80°C
no CSA! no 714
no no 7,6 mm IEC 60332-1-2
100 OHM Profibus PA Long Distance 1x2x1,6/ 3,2 mm PVC black, no 800715 -40°C to +70°C
no CSA! UL Style 2571 no 716
no no 9,5 mm IEC 60332-1-2
100 OHM Profibus PA 1x2x1,0/2,55 mm PVC blue EX, UL Style 2571, no CSA no 82835 -30°C to +80°C
no 714
no no 7,6 mm IEC 60332-1-2
100 OHM Profibus PA Long Distance 1x2x1,6/3,2 mm PVC blue EX no SCA, UL Style 2571 no 800650 -40°C to +70°C
no 716
no no 9,5 mm IEC 60332-1-2
* Extremely oil resistant: Please contact us first for special applications.
AUR = A vailable upon request, or refer to the Data, Network and BUS Technology catalog

11
BUS CABLES | Flexible cables for fixed installation or occasional movements

Jacket material
UV- Temperature
BUS system

Installation
Part number
resistant range

range
Cat.
Impedance without UL Standard
Increased page
Laying Outer-Ø Flame
oil
outside ca. resistant
resistance*
Halogen-free cables are marked in red

Indoor
CAN BUS 120 OHM

Cables are only available with UL/CSA standard; shown on the opposite column, right page
PVC

120 OHM CAN Bus direct burial, PE yes 804268 -40°C to +70°C
Outdoor

AUR
1x2x0,50 mm² yes no 9,2 mm no
120 OHM CAN Bus direct burial, PE yes 804269 -40°C to +70°C
AUR
4x1x0,50 mm² yes no 9,7 mm no
Indoor
resistant
PUR

Cables are only available with UL/CSA standard; shown on the opposite column, right page
oil-

Indoor
PVC

Cables are only available with UL/CSA standard; shown on the opposite column, right page
Halogen-free cables are marked in red
DEVICENET 120 OHM

Indoor
FRNC

Cables are only available with UL/CSA standard; shown on the opposite column, right page
resistant

Indoor
PUR
Oil-

Cables are only available with UL/CSA standard; shown on the opposite column, right page
Indoor
CPE

Cables are only available with UL/CSA standard; shown on the opposite column, right page
Halogen-free cables are marked
INTER BUS 100 OHM

Indoor
PVC

Cables are only available with UL/CSA standard; shown on the opposite column, right page

100 OHM I-BUS long-distance BUS, fixed installation indoor halogen-free pastel-turquoise
Indoor

no 81557 -25°C to +60°C


in red

FRNC

3x2x0,22 743
no - 7,0 mm IEC 60332-1-2
100 OHM I-BUS long-distance BUS, drag chain PUR pastel-turquoise no 81203 -20°C to +70°C
Oil-resistant

744
Indoor

3x2x025, for use in cable tracks. no yes 7,6 mm IEC 60332-1-2


PUR

100 OHM I-BUS Insta long-distance BUS, drag chain PUR pastel-turquoise no 82696 -20°C to +70°C
3x2x0,25 + 3x1,0, for use in cable tracks. 744
no yes 8,6 mm IEC 60332-1-2
- A-BUS EPDM yelow 2x1,5 mm 2
no 80824 -40°C to +85°C
747
no yes - no
EPDM (rubber)

- A-BUS EPDM black 2x1,5 mm 2


yes 80825 -40°C to +85°C
747
Indoor

no yes - no
- A-BUS EPDM yellow 2x2,5 mm2 no 804408 -40°C to +85°C
748
no no - no
Halogen-free cables are marked in red

- A-BUS EPDM black 2x2,5 mm2 yes 804409 -40°C to +85°C


748
no no - no
AS-INTERFACE

- A-BUS TPE yellow 2x1,5 mm2 no 801846 -40°C to +105°C


751
Indoor

no yes - IEC 60332-1-2


TPE

- A-BUS TPE black 2x1,5 mm2 yes 801847 -40°C to +105°C


751
no yes - IEC 60332-1-2
Indoor
FRNC

Cables are only available with UL/CSA standard; shown on the opposite column, right page
Oil-resistant PUR

Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right page

FOUNDATION
Fieldbus

PVC

Cables are only available with UL/CSA standard; shown on the opposite column, right page

* Extremely oil resistant: Please contact us first for special applications.


12
Flexible cables for fixed installation or occasional movements

UV- Temperature
Part number
resistant range
Impedance acc. to UL/CSA Cat.
NFPA
(please note exceptions) page
Laying Increased Outer-Ø Flame
outside oil resistance* ca. resistant
120 OHM CAN Bus 1x2x0,22 mm2 PVC violet UL style 2571 no 81286 -40°C to +70°C
no CSA! no 731
no no 5,4 mm IEC 60332-1-2
120 OHM CAN Bus 4x1x0,22 mm2 PVC violet UL style 2571 no 81287 -40°C to +70°C
no CSA! no 731
no no 6,9 mm IEC 60332-1-2
120 OHM CAN Bus 2x2x0,22 mm PVC violet UL style 2571
2
no 82509 -25°C to +70°C
no 732
no no 7,5 mm IEC 60332-1-2
120 OHM CAN Bus 1x2x0,34 mm PVC violet UL style 2571
2
no 801572 -30°C to +70°C
no CSA! no 734
no no 6,5 mm IEC 60332-1-2
120 OHM CAN Bus 4x1x0,34 mm2 PVC violet UL style 2571 no 801573 -30°C to +70°C
no CSA! no 734
no no 8,0 mm IEC 60332-1-2
120 OHM CAN Bus 2x2x0,34 mm2 PVC violet CMX no 803344 -40°C to +70°C
yes 735
no no 8,5 mm IEC 60332-1-2
120 OHM CAN Bus 1x2x0,5 mm PVC violet UL style 2571
2
no 800571 -40°C to +70°C
no CSA! no 736
no no 7,0 mm IEC 60332-1-2
120 OHM CAN Bus 4x1x0,5 mm PVC violet UL style 2571
2
no 800685 -40°C to +70°C
no CSA!! no 736
no no 8,5 mm IEC 60332-1-2
120 OHM CAN Bus 2x2x0,5 mm2 PVC violet CMX no 803722 -40°C to +70°C
yes 737
no no 9,6 mm IEC 60332-1-2
120 OHM CAN Bus 1x2x0,75 mm2 PVC violet UL style 2571 no 803383 -40°C to +70°C
no 739
no no 8,3 mm IEC 60332-1-2
120 OHM CAN Bus 4x1x0,75 mm PVC violet UL style 2571
2
no 803384 -40°C to +70°C
no 739
no no 8,8 mm IEC 60332-1-2

Cables are only available without UL/CSA standard; shown on the opposite column, left page

120 OHM CAN Bus 105°C 4xAWG24 PUR violet UL style 21223 no 801982 -40°C to +105°C
no 733
no yes 8,4 mm IEC 60332-1-2

120 OHM DeviceNet™ Thick PVC gray 1x2xAWG18 + 1x2xAWG15 no 800683 -20°C to +80°C
CMG yes 753
no yes 12,2 mm IEC 60332-1-2
120 OHM DeviceNet™ Thin PVC gray 1x2xAWG24 + 1x2xAWG22 no 800684 -20°C to +80°C
CMG yes 753
no yes 6,9 mm IEC 60332-1-2
120 OHM DeviceNet™ Thick FRNC violet 1x2xAWG18 + 1x2xAWG15, no 800681 -25°C to +80°C
CL2 CMG yes 754
no no 12,2 mm IEC 60332-1-2
120 OHM DeviceNet™ Thin FRNC violet 1x2xAWG24 + 1x2xAWG22, no 800682 -25°C to +80°C
CL2 CMG yes 754
no no 6,9 mm IEC 60332-1-2
120 OHM DeviceNet™ Thick PUR violet 1x2xAWG18 + 1x2xAWG15, no 81909 -40°C to +80°C
CMX yes 756
no yes 12,2 mm VW1
120 OHM DeviceNet™ Thin PUR violet 1x2xAWG24 + 1x2xAWG22, no 81910 -40°C to +80°C
CMX yes 756
no yes 6,9 mm VW1
120 OHM DeviceNet™ Thick CPE yellow 1x2xAWG18 + 1x2xAWG15 CMG PLTC no 81907 -20°C to +60°C
yes 755
no no 12,0 mm FT4
120 OHM DeviceNet™ Thin CPE yellow 1x2xAWG24 + 1x2xAWG22 CL2 CMG no 81908 -20°C to +60°C
yes 755
no no 7,0 mm FT4
100 OHM I-BUS long-distance BUS, fixed installation indoor PVC pastel-turquoise no 80778 -40°C to +70°C
3x2x0,22, no CSA! UL style 2571 no 742
no - 7,0 mm IEC 60332-1-2
100 OHM I-BUS Insta long-distance BUS, fixed installation indoor PVC pastel-turquoise no 81202 -40°C to +70°C
3x2x0,22 + 3x1,0, no CSA! UL style 2571 no 742
no - 8,0 mm IEC 60332-1-2

Cables are only available without UL/CSA standard; shown on the opposite column, left page

Cables are only available without UL/CSA standard; shown on the opposite column, left page

Cables are only available without UL/CSA standard; shown on the opposite column, left page

- A-BUS TPE, UL CMG, black yes 804693 -40°C to +105°C


yes AUR
2x1,5 mm² no yes - IEC 60332-1-2
- A-BUS TPE, UL CMG, yellow no 805694 -40°C to +105°C
yes AUR
2x1,5 mm² yes yes - IEC 60332-1-2
- A-BUS for switch cabinets FLIH yellow 2x0,86/2,5, UL style 20549 no 802183 -25°C to +70°C
no CSA! no 752
no yes - IEC 60332-1-2
- A-BUS PUR yellow 2x1,5 mm UL style 20549
2
no 82434 -40°C to +80°C
no 749
no yes - IEC 60332-1-2
- A-BUS PUR black 2x1,5 mm UL style 20549
2
yes 82822 -40°C to +80°C
no 749
no yes - IEC 60332-1-2
- A-BUS PUR yellow 2x2,5 mm2 UL Style 21866 no 804410 -40°C to +80°C
no 750
no yes - FT2
- A-BUS PUR black 2x2,5 mm2 UL Style 21866 yes 804411 -40°C to +80°C
no 750
no yes - FT2
100 OHM FOUNDATION™ Fieldbus Basic 1x2x1,1/2,55 PVC orange CMG PLTC yes 803354 -40°C to +80°C
yes 720
no no 8,0 mm IEC60332-3
100 OHM FOUNDATION™ Fieldbus Typ A+green yellow 1x2x1,1/2,85 + 1x0,8 PVC yellow CMG CL3 yes 801191 -25°C to +105°C
yes 721
no no 7,9 mm IEC60332-3
100 OHM FOUNDATION™ Fieldbus Typ A armoured 1x2x1,1/2,85 + 1x0,8 PVC yellow CMG PLTC yes 801192 -25°C to +105°C
yes 722
no no 12,3 mm IEC60332-3
AUR = A
 vailable upon request, or refer to the Data, Network and BUS
Technology catalog 13
CONTROL CABLE | Highly flexible cables for continuous movements, such as cable tracks

Cable track class


Conductor Temperature
UV-resistant Color

Shielding
material
Jacket number range
Voltage Cat.
without UL Standard
class Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
300/ 500V JZ-HF no gray 2 - 65 -10°C to +80°C
highly flexible, numbered, oil-resistant, VDE-Reg. 160
no yes 0.5 - 16 -40°C to +80°C
without
shield

300/ 500V MULTISPEED® 500-PVC yes black 2 - 42 -15°C to +80°C


Highly flexible, numbered, low torsion, 7 or more conductors are bunch stranded 162
yes yes 0.5 - 2.5 -30°C to +80°C

300/ 500V JZ-HF-CY no gray 2 - 61 -10°C to +80°C


PVC

Highly flexible, shielded, VDE-Reg., oil-resistant 163


no yes 0.5 - 16 -40°C to +80°C
Halogen-free cables are marked in red / Bio-oil & fuel-resistant cables are marked in green

300/ 500V MULTISPEED® 500-C-PVC yes black 2 - 25 -15°C to +80°C


Highly flexible, numbered, low torsion, 7 or more conductors are bunch stranded, Cu-shielded 165
shield

yes yes 0.5 - 2.5 -30°C to +80°C


with

300/ 500V PURö-JZ-HF yes gray 2 - 65 -20°C to +80°C


Highly flexible, coolant-resistant, oil-resistant 167
yes yes 0.5 - 95 -40°C to +80°C
300/ 500V MULTIFLEX 512®-PUR yes gray 2 - 65 -30°C to +80°C
highly flexible, extreme conditions, numbered, halogen-free, oil-resistant, 169
yes yes 0.5 - 16 -50°C to +80°C
Control cables

without

300/ 500V MULTISPEED® 500-PUR yes black 2 - 42 -30°C to +80°C


shield

safety against high bending, low torsion, halogen-free, 7 or more conductors are bunch yes yes 0.5 - 2.5 -40°C to +80°C 171
stranded
Oil-resistant PUR

0,6/ 1kV TOPFLEX® 611-PUR yes gray 4 -30°C to +80°C


Motor power supply, halogen-free 199
yes yes 1.5 - 120 -40°C to +80°C
300/ 500V PURö-JZ-HF-YCP yes gray 2 - 65 -20°C to +80°C
Highly flexible, numbered, Cu-shielded, 172
yes yes 0.5 - 16 -40°C to +80°C
300/ 500V MULTIFLEX 512®-C-PUR yes gray 2 - 36 -30°C to +80°C
highly flexible, extreme conditions, halogen-free, Cu-shielded 174
yes yes 0.5 - 16 -40°C to +80°C
shield
with

300/ 500V MULTISPEED® 500-C-PUR yes dark blue 2 - 25 -30°C to +80°C


safety against high bending, low torsion, halogen-free, 7 or more conductors are bunch yes yes 0.5 - 2.5 -40°C to +80°C 176
stranded, Cu-shielded
0,6/ 1kV TOPFLEX® 611-C-PUR no gray 4 -30°C to +80°C
Motor power supply, halogen-free, Cu-shielded no yes 1.5 - 120 -40°C to +80°C 200

300/ 500V MULTISPEED® 500-TPE yes dark blue 2 - 42 -30°C to +80°C


safety against high bending, low torsion, halogen-free, 7 or more conductors are bunch
without

yes yes 0.5 - 35 -40°C to +80°C 177


shield
Oil-resistant TPE-O

stranded
300/ 500V KOMPOSPEED JZ-HF-500 yes black 2 - 25 -30°C to +90°C
Highly flexible, halogen-free, numbered, microbe-resistant 184
yes yes 0.5 - 2.5 -40°C to +100°C
300/ 500V MULTISPEED® 500-C-TPE yes dark blue 2 - 25 -30°C to +80°C
safety against high bending, low torsion, halogen-free, shielded, 7 or more conductors yes yes 0.5 - 4 -40°C to +80°C 179
shield
with

are bunch stranded


300/ 500V KOMPOSPEED JZ-HF-500-C yes black 2 - 25 -30°C to +90°C
Highly flexible, halogen-free, numbered, Cu-shielded, microbe-resistant 185
yes yes 0.5 - 2.5 -40°C to +100°C
* Extremely oil resistant: Please contact us first for special applications.

Cable glands

Cable glands

For standard applications:


· Plastic
· Stainless steel
For specific applications:
· Electromagnetic compatibility
· Robust applications
· Increased temperature
· Hazardous area
· S pecial pressure & installation condi-
tions

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

14
Highly flexible cables for continuous movements, such as cable tracks
Cable track class

Conductor Temperature
UV-resistant Color
number range
Voltage Cat.
According to UL/CSA NFPA
class Flexing page
Laying Increased Cross
outside oil resistance* section Fixed installation
600V JZ-602 RC yes black 3 - 34 -5°C to +90°C
highly flexible, red conductors no 423
yes yes 0.5 - 35 -40°C to +90°C
600V MULTISPEED® 500-PVC UL/CSA yes black 2 - 42 -5°C to +80°C
safety against high bending, low torsion, 7 or more conductors are bunch stranded, extruded as filler w/ pressure no 425
yes yes 0.5 - 2.5 -30°C to +80°C
600V MULTIFLEX 600 yes black 2 - 60 -5°C to +90°C
Highly flexible, oil-resistant, numbered, for exposed run TC-ER, PLTC-ER, ITC-ER yes AWG20 - AWG2 424
yes yes -40°C to +90°C
600V JZ-602 RC-CY yes black 3 - 34 -5°C to +90°C
Highly flexible, Red conductors, shielded (D-shield) no 427
yes yes 0.5 - 35 -40°C to +90°C
600V MULTISPEED® 500-C-PVC UL/CSA yes black 2 - 25 -5°C to +80°C
safety against high bending, low torsion, with inner jacket, Cu-shielded, 7 or more conductors are bunch stranded no 429
yes yes 0.5 - 2.5 -30°C to +80°C
600V MULTIFLEX 600-C yes black 2 - 60 -5°C to +90°C
Highly flexible, oil-resistant, numbered, Cu-shielded, for exposed run TC-ER, PLTC-ER, ITC-ER yes AWG20 - AWG2 428
yes yes -40°C to +90°C
1kV JZ-HF-FCY no gray 2 - 25 -5°C to +80°C
Highly flexible, oil-resistant, numbered, Cu-shielded, no AWG20 - AWG12 426
no no -40°C to +80°C
600V JZ 602 RC-PUR yes gray 3 - 34 -5°C to +80°C
Highly flexible, numbered no 430
yes no 0.5 - 35 -40°C to +80°C
600V MULTIFLEX 512®-PUR UL/CSA yes gray 2 - 65 -30°C to +80°C
Highly flexible, numbered, halogen-free, two approval no 431
yes yes 0.5 - 16 -40°C to +80°C
600V MULTISPEED® 500-PUR UL/CSA yes black 2 - 42 -30°C to +80°C
safety against high bending, numbered, low torsion, halogen-free, 7 or more conductors are bunch no yes yes 0.5 - 2.5 -40°C to +80°C 433
stranded

1kV PURö-JZ-HF-FCP yes gray 2 - 25 -5°C to +80°C


Highly flexible, oil-resistant, Cu-shielded no 435
yes yes 0.5 - 4 -40°C to +80°C
600V JZ-602 RC-C-PUR yes gray 3 - 34 -5°C to +80°C
Highly flexible, numbered, with inner jacket, D-shield no 436
yes no 0.5 - 35 -40°C to +80°C
600V MULTIFLEX 512®-C-PUR UL/CSA yes gray 2 - 65 -30°C to +80°C
Highly flexible, numbered, halogen-free, two approval, Cu-shielded no yes yes 0.5 - 16 -40°C to +80°C 437

600V MULTISPEED 500-C-PUR UL/CSA


®
yes black 2 - 36 -30°C to +80°C
safety against high bending, numbered, low torsion, halogen-free, 7 or more conductors are bunch no yes yes 0.5 - 2.5 -40°C to +80°C 439
stranded, Cu-shielded,
1kV MULTISPEED® 500-TPE UL/CSA yes gray 2 - 25 -30°C to +80°C
safety against high bending, highly flexible, low torsion no yes yes 0.5 - 2.5 -40°C to +80°C 441

1kV MULTISPEED® 500-C-TPE UL/CSA yes gray 2 - 25 -30°C to +80°C


safety against high bending, highly flexible, low torsion no yes yes 0.5 - 2.5 -40°C to +80°C 443

* Extremely oil resistant: Please contact us first for special applications.

Tools

Tools

· Cable shear
· Dismantling/stripping
· Crimping/Pressing
· Shield-Kon tools
· Fastening
· Cable tie tools
· Handling
· Mounting

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

15
DATA CABLES | Highly flexible cables for continuous movements, such as cable tracks
Conductor

Cable track class


Voltage number/ Temperature
UV-resistant Color

Shielding
material
Jacket class Number of range
Cat.
(Peak without UL Standard pairs
page
operating Flexing
Laying Increased oil Cross
voltage)
outside resistance* section Fixed installation
300/ 500V SUPERTRONIC®-PVC no gray 2 - 25 -5°C to +70°C
without

Track cable, color code acc. to DIN 47100 187


shield

no no 0.14 - 0.34 -40°C to +70°C


350V SENSORFLEX no gb/or 3-5 -5°C to +80°C
Senor actuator cable, color coded 128
no no 0.25 - 0.34 -30°C to +80°C
PVC
Halogen-free cables are marked in red

300/ 500V SUPERTRONIC®-C-PVC no gray 2 - 25 -5°C to +70°C


Track cable, color code acc. to DIN 47100, Cu-shielded 188
shield

no no 0.14 - 0.34 -40°C to +70°C


with
Data cables

300V SUPERTRONIC®-PURö yes gray 2 - 25 -5°C to +70°C


Track cable, color code acc. to DIN 47100, Cu-shielded 189
without

yes yes 0.14 - 0.34 -40°C to +70°C


shield
Oil-resistant PUR

300/ 500V SUPERTRONIC®-C-PURö yes gray 2 - 25 -30°C to +70°C


Track cable, halogen-free, color code acc. to DIN 47100, Cu-shielded 190
yes yes 0.14 - 0.34 -40°C to +70°C
300/ 500V SUPER-PAAR-TRONIC-C-PUR ®
yes gray 1 - 14 -30°C to +70°C
shield
with

Track cable, twisted pairs, color code acc. to DIN 47100, Cu-shielded 191
yes yes 0.25 - 1 -40°C to +70°C

SINGLE Conductor | Highly flexible cables for continuous movements, such as cable tracks
Cable track class

Conductor Temperature
UV-resistant Color
Shielding
material

number range
Jacket

Voltage Cat.
without UL Standard
class Flexing page
Laying Increased oil Cross
outside resistance* section Fixed installation
with without
shield shield
PVC
Halogen-free cables are marked in red
Single conductors

without
shield
Oil-resistant PUR

with shield

0,6/ 1kV KOMPOSPEED 600 yes bw 1 -30°C to +90°C


with without
Shield Shield

double insulated, halogen-free, for cable tracks 322


TPE-O

yes no 6 - 185 -40°C to +100°C


0,6/ 1kV KOMPSPEED 600-C yes bw 1 -30°C to +90°C
double insulated, halogen-free, for cable tracks, Cu-shielded 322
yes no 6 - 240 -40°C to +100°C
* Extremely oil resistant: Please contact us first for special applications.

Insulated, shrink, braided, and temperature protection tubes

Insulated, shrink, braided, and


temperature protection tubes

· Insulation tubes
·H
 eat shrink tubing
·B
 raided hose
·H
 igh-temperature protection
·E
 nd caps

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

16
Highly flexible cables for continuous movements, such as cable tracks

Conductor
Cable track class

Temperature
UV-resistant Color number/
range
Voltage Number of pairs Cat.
According to UL/CSA NFPA
class page
Laying Increased Cross Flexing
outside oil resistance* section Fixed installation
300V SUPERTRONIC®-310-PVC no gray 2 - 25 -5°C to +80°C
Track cable, conductors acc. to DIN 47100 no 445
no no 0.14 - 0.34 -40°C to +80°C

300V SUPERTRONIC®-310-C-PVC no gray 2 - 25 -5°C to +80°C


Track cable, conductors acc. to DIN 47100, Cu-shielded no 446
no no 0.14 - 0.34 -40°C to +80°C

300V SUPERTRONIC®-330-PURö yes gray 2 - 25 -30°C to +80°C


Track cable, halogen-free, conductors acc. to DIN 47100 no 447
yes yes 0.14 - 0.34 -40°C to +80°C
300V MULTISPEED®-TRONIC-PUR yes black 2 - 25 -30°C to +80°C
Track cable, conductors acc. to DIN 47100, 7 or more conductors are bunch stranded, extruded as no yes no 0.25 - 0.34 -40°C to +80°C 448
filler with pressure
300V SUPERTRONIC®-330-C-PURö yes gray 2 - 25 -30°C to +80°C
Track cable, conductors acc. to DIN 47100, Cu-shielded no 449
yes yes 0.14 - 0.34 -40°C to +80°C
300V SUPER-PAAR-TRONIC-340-C-PUR yes gray 1 - 14 -30°C to +80°C
Track cable, twisted pairs, halogen-free, conductors acc. to DIN 47100, Cu-shielded no 451
yes yes 0.25 - 1 -40°C to +80°C
300V MULTISPEED®-TRONIC-C-PUR yes black 2 - 25 -30°C to +80°C
Track cable, Cu-shielded, conductors acc. to DIN 47100, 7 or more conductors are bunch stranded, no yes no 0.25 - 0.34 -40°C to +80°C 450
extruded as filler with pressure
Cable track class

Conductor Temperature
UV-resistant Color
number range
Voltage Cat.
According to UL/CSA NFPA
class Flexing page
Laying Increased Cross
outside oil resistance* section Fixed installation
600V SINGLE 602-RC -J/-O no bw 1 -5°C to +90°C
Special cable tracks, conductors 90°C,600V no 501
no no 10 - 300 -40°C to + 90°C
600V SINGLE 602-RC-CY -J/-O no orange 1 -5°C to +90°C
Special cable tracks, conductors 90°C,600V, shielded no 502
no no 10 - 300 -40°C to + 90°C
TOPFLEX 301
®
no bw 1 -15°C to +80°C T9
unshielded, double insulated single conductor no no yes 6 - 240 -

0,6/ 1kV MULTISPEED® 600-PUR -J/-O yes bw 1 -30°C to +80°C


Special cable tracks, conductors 90°C, 600V, halogen-free no 504
yes no 6 - 300 -40°C to +90°C
TOPFLEX® 301-C no bw 1 -15°C to +80°C
shielded, double insulated single conductor no T9
no yes 6 - 240
0,6/ 1kV MULTISPEED® 600-C-PUR -J/-O yes bw 1 -30°C to +80°C
Special cable tracks, conductors 90°C, 600V, shielded, halogen-free no 505
yes no 6 - 300 -40°C to +90°C

* Extremely oil resistant: Please contact us first for special applications.

Ferrules and cable lugs

Ferrules and cable lugs

· Ferrules
· Shield connectors
· Solderless terminals
· Tubular cable lugs
· Compression joints

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

17
MOTOR and SERVO CABLES | Highly flexible cables for continuous movements, such as cable tracks
Conductor

Cable track class


number/ Temperature
UV-resistant Color

Shielding
material
Jacket Number of range
Voltage Cat.
without UL Standard pairs
class page
Laying Increased oil Cross Flexing
without with without outside resistance* section Fixed installation
shield Shield shield
PVC
Motor and servo cables
Halogen-free cables are marked in red

0,6/ 1kV TOPFLEX®611-PUR yes gray 4 -30°C to +80°C


Motor cable without pair, highly flexible, numbered, halogen-free 199
yes yes 1.5 - 120 -40°C to +80°C
Oil-resistant PUR

0,6/ 1kV TOPFLEX®611-C-PUR yes gray 4 -30°C to +80°C


Motor cable without pair, Cu-shielded. highly flexible, numbered, halogen-free 200
yes yes 1.5 - 120 -40°C to +80°C
shield

0,6/ 1kV TOPSERV® 110 yes teal 4+2 -30°C to +80°C


with

Servo cables with 1 pair 201


yes yes 1.5 - 50 -40°C to +80°C
0,6/ 1kV TOPSERV® 120 yes teal 4+2+2 -30°C to +80°C
Servo cables with 2 pairs 201
yes yes 1.5 - 50 -40°C to +80°C
without
shield
TPO

shield
with

FEEDBACK CABLE | Highly flexible cables for continuous movements, such as cable tracks
Conductor
Cable track class

number/ Temperature
UV-resistant Color
Shielding
material

Number of range
Jacket

Voltage Cat.
without UL Standard pairs
class page
Laying Increased oil Cross Flexing
outside resistance* section Fixed installation
without
Halogen-free cables are marked in red

shield
Feedback cables

PVC

350 V Feedback cable PVC no gray 10 + 4 -5°C to +70°C


shield

Colored conductors
with

202
no no 0.14 - 0.5 -30°C to +80°C
without
Oil-resistant PUR

shield

300 V Feedback cable PUR yes gray - -30°C to +80°C


Shield
with

203
yes yes - -40°C to +80°C

* Extremely oil resistant: Please contact us first for special applications.

HELUTEC® SIGNAL AND POWER PLUG CONNECTORS

The innovative The Patented Special Development The freely customizable


HELUTEC® system for the HELUTEC® Series 615/915 connector
This sensational, quick Fits in tight locations. In areas Bonded for life. This overmolded
fastening connector is safe and with limited space, just wind connector consists of a housing
stable while saving time and the pre-tensioned lock nut and the overmold, which are
installation costs. The vibration before sliding the nut into bonded together and cannot be
resistant lock mechanism was the lock position. A small disassembled. This provides the
perfected for plug connectors rotation with a little pull at required manipulation security
sizes M17, M23 and M40, the plug releases the lock nut for customized units - a design
which can be found in the preventing an unintended that is normally only available for
HELUTEC® series 617, 917, 623, release of the vibration cast versions. All commercially
723, 923 and 940. The resistant quick fastener. Only a available cables at any length
HELUTEC® angle junction quarter turn and a slight pull can be connected to the inner
boxes can be easily combined on the connector is required section of the robust metal
at any time with the HELUTEC® to disconnect. The connection housing. This is for both options:
system or with standard lock is absolutely vibration proof. Standard screw connections
nuts. This also addresses This was specially developed or those items that include a
the issue of downward and patented for the HELUTEC® patented fast lock system. For
compatibility. series 615/915. almost any pin design.
Slide it on and rotate for a
tight fit. Patented perfection
included.

18
Highly flexible cables for continuous movements, such as cable tracks

Conductor
Temperature
UV-resistant Color number/
range
Voltage Number of pairs Cat.
According to UL/CSA NFPA
class page
Laying Increased Cross Flexing
outside oil resistance* section Fixed installation

0,6/ 1kV TOPSERV® PVC no orange 4 -0°C to +60°C


see catalog for Cable track class no 465
no yes 1.5 - 50 -20°C to +80°C

1kV TOPSERV® Hybrid yes orange 8 -30°C to +80°C


Hybrid cable for SICK HIPERFACE DSL motor-feedback systems no 474
yes no 0.5 - 16 -40°C to +80°C
0,6/ 1kV TOPSERV® PUR yes orange 4 -30°C to +80°C
no 468
yes yes 1.5 - 50 -40°C to +80°C
0,6/ 1kV TOPSERV® 109 Single no orange 1 -30°C to +80°C
Track cable, halogen-free, meter marking no AUR
no yes 6 - 50 -40°C to +80°C

0,6/ 1kV TOPSERV® 600 VFD yes or o. bw 4 -25°C to +90°C


Motor cable without pair, highly flexible yes 472
yes no 1,5 - 35 -
0,6/ 1kV TOPSERV® 650 VFD yes or o. bw 4 -25°C to +105°C
Servo cable with single pair, highly flexible yes 473
yes no 1,5 - 35 -
Siemens 6FX5008…, Siemens 6FX8008Plus… are registered trademarks of SIEMENS AG and are intended exclusively for comparative purposes. INDRAMAT INK… are registered trademarks of BOSCH
REXROTH AG and are intended exclusively for comparative purposes. LENZE … are registered trademarks of LENZE AG and are intended exclusively for comparative purposes.
* Extremely oil resistant: Please contact us first for special applications.

Conductor
Cable track class

Temperature
UV-resistant Color number/
range
Voltage Number of pairs Cat.
According to UL/CSA NFPA
class page
Laying Increased Cross Flexing
outside oil resistance* section Fixed installation

30V + 300V TOPSERV® PVC


no gn o. or - -0°C to +60°C
see catalog for Cable track class no 467
no yes - -20°C to +80°C

30V + 300V TOPGEBER 512 PUR yes gn o. or - -30°C to +80°C


acc. to Siemens 6FX8008Plus, Lenze, Indramat, Elau, B+R, Heidenhain, Berger Lahr etc.
no 470
yes yes - -40°C to +80°C

Siemens 6FX5008…, Siemens 6FX8008Plus… are registered trademarks of SIEMENS AG and are intended exclusively for comparative purposes. INDRAMAT INK… are registered trademarks of BOSCH REX-
ROTH AG and are intended exclusively for comparative purposes. LENZE … are registered trademarks of LENZE AG and are intended exclusively for comparative purposes.
* Extremely oil resistant: Please contact us first for special applications.

HELUTEC®-Serie 617 / 623 / 627 HELUTEC®-Serie 917 / 923 / 932 / 940 / 958
Signal connectors – Controlling – Monitoring Power plug connectors – Strong and Safe
Stable, versatile, safe: HELUTEC® series can be Extremely resilient: HELUTEC® power plug
found where a safe connection is required within connectors accelerate torque heavy drive motors,
a limited installation space. The plug connectors spindle drives and servo motors reliably up to
in the 617, 623 and 627 series are designed the highest rotational speeds while tolerating
especially for extra-low voltages, and are used in millions of abrupt starts and stops. Voltages up to
any application that transmits signals, controls 630 V and currents of up to 200 A are transferred
motors or monitors the smooth functioning of a reliably even in continuous operation and under
system. the most demanding conditions. Cable cross
For this purpose, a multitude of multi-pin sections of up to 50 mm² and the smallest possible
insulation bodies - matching a variety of different designs are - depending on the application - part
designs such as plugs, couplings and flush- of the scope of delivery as well as a perfect EMC
mounted boxes - are available for the user. shielding for the highest operational and work
Consequently, safety.
HELUTEC® engineers are able to handle a Strong vibrations and sudden stops have no
multitude of customer-specific connector impact on these plug connectors in day-to-day
requirements in a very innovative way. operations

Online configurator:
www.helutec.de

19
PROFINET / INDUSTRIAL ETHERNET | Highly flexible cables for continuous movements, such as cable tracks

Cable track class


UV-resistant Part no. Temperature range

Category
material
Jacket frequency Cat.
without UL Standard
range page
Laying Increased oil Outer-Ø
Flame resistance
outside resistance* ca.
HELUKAT® 200S SF/UTP, drag chain no 800088 -25°C to +70°C
** 100 MHz 4 x 1 x AWG24/19 696
CAT 5
no yes 6,2 mm IEC 60332-1-2
PUR

HELUKAT® 200S SF/UTP, drag chain no 81155 -25°C to +70°C


** 100 MHz 4x2xAWG24/19 697
no yes 9,5 mm IEC 60332-1-2
PUR or PVC
Halogen-free cables are marked in red
Industrial Ethernet

CAT 5e

Cables are only available with UL/CSA standard; shown on the opposite column, right
page
CAT 6 / CAT 6A

Cables are only available with UL/CSA standard; shown on the opposite column, right
page
PUR or PVC

CAT 7

Cables are only available with UL/CSA standard; shown on the opposite column, right
page

BUS CABLES | Highly flexible cables for continuous movements, such as cable tracks
Cable track class

Temperature
Installation

UV-resistant Part no.


material

range
Jacket

range

Cat.
Impedance without UL Standard
page
Laying Increased oil Outer-Ø Flame-
outside resistance* ca. retardant
Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right
Halogen-free cables are marked in red

PVC

**
page
150 OHM Profibus L2 drag chain 1x2x0,64 mm (Litze) PUR teal no 81003 -30°C to +70°C
** 709
no yes 8,0 mm IEC60332-1
Profibus

150 OHM Profibus L2 drag chain 1x2x0,64 mm (Litze) PUR violet no 80267 -30°C to +70°C
Oil-resistant PUR

** 709
no yes 8,0 mm IEC60332-1
Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right
page

120 OHM CAN Bus drag chain 1x2x0,25 mm2 PUR violet no 81911 -40°C to +70°C
** 740
no yes 6,1 mm no
Oil-resistant
CANBUS

120 OHM CAN Bus drag chain 4x1x0,25 mm PUR violet


2
no 81912 -30°C to +70°C
Indoor

** 740
PUR

no yes 6,5 mm no
DEVICENET

Oil-resistant

Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right
PUR

page
AS-INTERFACE

Oil-resistant PUR

Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right
page

DESINA-HYBRID BUS POF + 4x1,5 no 81713 -20°C to +80°C


** 712
Indoor

no yes 8,8 mm no
POF

PUR

POF/PA 2P980 I-V4Y(ZN)11Y no 801201 -20°C to +70°C


** 649
no yes 8,0 mm no
* Extremely oil resistant: Please contact us first for special applications.
** Cable track classes are available on request (dnb@helukabel.com).

20
Highly flexible cables for continuous movements, such as cable tracks
Cable track class

UV-resistant Part no. Temperature range


frequency Cat.
According to UL/CSA NFPA
range page
Laying Increased Outer-Ø Flame-
outside oil resistance* ca. retardant
HELUKAT® 100T SF/UTP, Tordierflex UL Style 20963 no 800067 -40°C to +80°C
** 100 MHz 4x2xAWG26/19, Torsion no 698
no yes 7,5 mm IEC 60332-1-2

HELUKAT® 100IND PROFInet C, highly flexible CMG, PVC no 802914 -20°C to +70°C
** 100 MHz 2x2xAWG22/7, Fast Connect yes AUR
no yes 6, 5mm IEC 60332-3
HELUKAT 100IND PROFInet C, highly flexible CMX, PUR
®
no 800655 -20°C to +70°C
** 100 MHz 2x2xAWG22/7, Fast Connect yes 703
no yes 6,5 mm IEC 60332-1-2
HELUKAT® 100IND PROFInet C, Torsion UL Style 21161 no 802186 -40°C to +80°C
** 100 MHz 2x2xAWG26/19, no CSA! no 704
no yes 6,5 mm IEC 60332-1-2
HELUKAT® 100S SF/UTP, drag chain ECO, UL Style 20963 no 82838 -40°C to +80°C
** 155 MHz 4x1xAWG26/19 no 694
no yes 4,8 mm IEC 60332-1-2
HELUKAT® 100S SF/UTP, drag chain ECO, UL Style 20963 no 82839 -40°C to +80°C
** 155 MHz 4x2xAWG26/19 no 695
no yes 6,6 mm IEC 60332-1-2
HMCB500S Industrial Ethernet PVC green UL Style 2502 no 803672 -20°C to +80°C
** 100 MHz 2x2xAWG24+1x2xAWG22 no 725
no no 6,8 mm no
HMCB800W Industrial Ethernet PUR green UL Style 20236 no 804767 -20°C to +60°C
** 100 MHz 2x2x0,20+1x2x0,38 no 726
no yes 6,95 mm no
HELUKAT® 250S SF/UTP, drag chain, CMX no 803387 -30°C to +70°C
** 250 MHz 4x2xAWG26/19 yes 691
no yes 7,8 mm IEC 60332-1-2
HELUKAT® Industrial Ethernet S/FTP, drag chain, CM, PVC no 805704 -10°C to +80°C
** 500 MHz 4x2xAWG24/7 yes AUR
no no 8,9 mm IEC 60332-3
HELUKAT® Industrial Ethernet S/FTP, drag chain, CMX, PUR no 805703 -40°C to +80°C
** 500 MHz 4x2xAWG24/7 no AUR
no yes 8,9 mm IEC 60332-1-2
HELUKAT® S/FTP, drag chain, CMX, PUR no 805548 -10°C to +70°C
** 500 MHz 4x2xAWG26/7 yes AUR
no yes 7,8 mm IEC 60332-1-2
HELUKAT® SF/FTP, drag chain, PUR no 805614 -30°C to +70°C
** 600 MHz 4x2xAWG24/7 yes AUR
no yes 8,7 mm IEC 60332-1-2
HELUKAT® SF/FTP, Torsion, PUR no 805828 -30°C to +70°C
** 600 MHz 4x2xAWG24/7 yes AUR
no yes 8,7 mm IEC 60332-1-2
Cable track class

Temperature
UV-resistant Part no.
range
Cat.
Impedance According to UL/CSA NFPA
page
Laying Increased Outer-Ø Flame-
outside oil resistance* ca. retardant
150 OHM Profibus L2 FESTOON 1x2x0,65 mm PVC teal CMG yes 800649 -40°C to +60°C
** yes 713
yes yes 8,0 mm EN 50265-2-1
150 OHM Profibus ET200X PUR teal UL Style 20351 no 82913 -5°C to +60°C
** 1x2x0,65+3x1x1,5 no 710
no yes 9,7 mm no
150 OHM Profibus ECOFAST TPU teal UL Style 20233 no 800044 -15°C to +60°C
** 1x2x0,65+4x1x1,5 no 710
no yes 11,5 mm IEC 60332-1-2
150 OHM Profibus L2 Torsion 1x2x0,8 mm PUR violet CMX no 800109 -25°C to +75°C
** yes 713
no yes 8,0 mm IEC60332-1
150 OHM Profibus SK drag chain 1x2x0,64 mm (Litze) PUR teal CMX no 81906 -40°C to +70°C
** Fast Connect yes 719
no yes 8,0 mm IEC 60332-1-2
150 OHM Profibus SK drag chain 1x2x0,64 mm (Litze) PUR violet CMX no 801659 -40°C to +70°C
** Fast Connect yes 719
no yes 8,0 mm IEC 60332-1-2

120 OHM CAN Bus drag chain 1x2x0,34 mm² PUR violet CMX no 802182 -30°C to +70°C
** no CSA! yes 741
no yes 6,9 mm IEC 60332-1-2
120 OHM CAN Bus drag chain 4x1x0,34 mm² PUR violet CMX no 802339 -30°C to +70°C
** no CSA! yes 741
no yes 7,5 mm IEC 60332-1-2
120 OHM CAN BUS drag chain 1x2x0,5 mm² no 805685
** CMX yes AUR
no yes 8,0 mm IEC 60332-1-2
120 OHM CAN BUS drag chain 4x2x0,5 mm² no 805696
** CMX yes AUR
no yes 8,2 mm IEC 60332-1-2

120 OHM DeviceNet™ Thick PUR violet 1x2xAWG18 + 1x2xAWG15 no 81909 -40°C to +80°C
** CMX yes 756
no yes 12,2 mm VW1
120 OHM DeviceNet™ Thin PUR violet 1x2xAWG24 + 1x2xAWG22 no 81910 -40°C to +80°C
** CMX yes 756
no yes 6,9 mm VW1

- A-BUS PUR yellow 2x1,5 mm² UL Style 20549 no 82434 -40°C to +80°C
** no 749
no yes - IEC 60332-1-2
- A-BUS PUR black 2x1,5 mm² UL Style 20549 yes 82822 -40°C to +80°C
** no 749
yes yes - IEC 60332-1-2
- A-BUS PUR yellow 2x2,5 mm² UL Style 20549 no 804410 -40°C to +80°C
** no 750
no yes -
- 804411 A-BUS PUR black 2x2,5 mm² UL Style 20549 yes 804411 -40°C to +80°C
** no 750
yes yes -

Cables are only available without UL/CSA standard; shown on the opposite column, left page

* Extremely oil resistant: Please contact us first for special applications.


** Cable track classes are available on request (dnb@helukabel.com).
AUR = Available upon request, or refer to the Data, Network and BUS Technology catalog

21
BUS CABLES | Highly flexible cables for continuous movements, such as cable tracks

Cable track class


Temperature

Installation
UV-resistant Part no.
material
Jacket range

range
Cat.
Impedance without UL Standard
page
Laying Increased oil Outer-Ø Flame-
outside resistance* ca. retardant
MULTI

Indoor
BUS

Cables are only available with UL/CSA standard; shown on the opposite column, right
PUR

page
USB 2.0 / 3.0

Indoor

Cables are only available with UL/CSA standard; shown on the opposite column, right
PUR

page
Safety

Indoor
BUS

Cables are only available with UL/CSA standard; shown on the opposite column, right
PUR

page

* Extremely oil resistant: Please contact us first for special applications.


** Cable track classes are available on request (dnb@helukabel.com).

End caps & ferrules

End caps & ferrules for

·T
 elecommunication cables
· Low-voltage
· Medium-voltage
·A
 ccessories/component parts

YOU WILL FIND ADDITIONAL


ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

Cable protection tube systems

Cable protection tube systems

Corrugated tubes:
· F or standard applications
· Oversized
· Dividable corrugated tubes:
Highly flexible cable tubes
·P
 lastic with coil springs
· Metal, spiral wound
Cable protection tubes for
heavy duty applications
YOU WILL FIND ADDITIONAL
ACCESSORIES IN THE CABLE
ACCESSORIES CATALOG!

22
Highly flexible cables for continuous movements, such as cable tracks
Cable track class

Temperature
UV-resistant Part no.
range
Cat.
Impedance According to UL/CSA NFPA
page
Laying Increased Outer-Ø Flame-
outside oil resistance* ca. retardant
see Multibus I 15-conductor highly flexible, Torsion C-UL no 801652 -30°C to +80°C
** catalog no 745
no no 14,7 mm yes
see Multibus II 15-conductor highly flexible, Torsion C-UL no 804115 -20°C to +80°C
** catalog no 746
no no 15,0 mm yes

90 OHM USB S 2.0 drag chain 1x2xAWG28 + 1x2xAWG20 UL Style 20963 no 802469 -30°C to +60°C
** no 727
no no 5,0 mm yes
90 OHM USB L 2.0 drag chain 1x2xAWG24 + 1x2xAWG20 UL Style 20963 no 802470 -30°C to +70°C
** no 728
no no 6,3 mm yes
90 OHM USB 3.0 drag chain 2x2xAWG28 + 2x2xAWG28 UL Style 20236 no 805287 -30°C to +70°C
** no 729
no no 6,5 mm yes

110 OHM SafetyBUS PUR yellow 3x0,75 CMX no 800652 -30°C to +80°C
** yes 758
no no 7,8 mm yes

* Extremely oil resistant: Please contact us first for special applications.


** Cable track classes are available on request (dnb@helukabel.com).

NOTES

Prices
Errors excepted. All prices are subject to change and without obligation

Technical modifications
© HELUKABEL® GmbH Hemmingen
Dimensions and specifications may change without prior notice. Consequently all illustrations, numerical data, etc. are provided without guarantee. Color deviations
between photos and delivered goods cannot be avoided. Reproduction or duplication of the text and illustrations, in whole or in part, remain reserved. The transfer
of copyrights requires the written consent of HELUKABEL® GmbH. Our General Terms of Delivery and Payment, which can be viewed at www.helukabel.com, apply.

Safety notice
The cables and wires described in the brochure are produced in accordance with national and international standards, as well as plant standards; application safety,
as stipulated in safety directives, standards, and statutory regulations, as amended, are provided. Following proper installation and usage guidelines, the possibility
of product-specific dangers can be excluded. This brochure describes general use information for each product. Independent of the above, the applicable DIN VDE
specifications apply. Installation and processing must only be executed by qualified electricians.

Our General Terms of Delivery and Payment, which can be viewed at www.helukabel.com, apply

23
HELUKABEL® USA, Inc. Headquarters Elgin, Illinois

WM/Cable finder/03.2016/2000/EN/WD

helukabel.com
HELUKABEL
24 USA . 1490 Crispin Dr. . Elgin, IL 60123 . Phone: 847-930-5118 . Toll Free: 855-HELUUSA . Fax: 847-622-8766 .sales@helukabel.com
®