0.3 0.5
k 0.31 0.33 0.35 0.51 0.53 0.55
0.1 0.3 0.5 0.1 0.3 0.5
1 0.16 0.22 0.26 0.16 0.22 0.25
1.2 0.20 0.27 0.30 0.20 0.27 0.30
1.5 0.26 0.33 0.36 0.26 0.33 0.36
2 0.35 0.40 0.44 0.35 0.40 0.44
2.5 0.41 0.46 0.49 0.41 0.46 0.49
3 0.45 0.50 0.53 0.45 0.50 0.53
4 0.52 0.56 0.58 0.52 0.56 0.59
5 0.56 0.60 0.62 0.56 0.60 0.63
6 0.60 0.63 0.65 0.60 0.63 0.66
8 0.64 0.67 0.68 0.64 0.67 0.69
10 0.67 0.70 0.71 0.67 0.70 0.71
0.7
0.71 0.73 0.75
0.1 0.3 0.5
0.16 0.22 0.28
0.20 0.27 0.31
REGRESAR
0.26 0.33 0.39
0.35 0.40 0.45 TABULAR
0.41 0.46 0.52 MINIMO 0.60 0.66
0.45 0.50 0.54 MAXIMO 0.80 0.75
0.52 0.56 0.61 RELACION 0.45
0.56 0.60 0.63 VALOR TABULADO PARA 0.7255
0.60 0.63 0.68 0.716475
0.64 0.67 0.71
0.67 0.70 0.72
regresar
regresar
SALA
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 13.80 m k K= 0.7255119
h(l  a )
ANCHO 5.70 m
ALTURA 5.56 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S 21804.775
E: Luminancia deseada T  Φt=
E= 150.00 Lum/m² n. fm

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.3 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.6764 N N= 12
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

ESTACIONAMIENTO
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.91 m k K= 0.7188361
h(l  a )
ANCHO 5.70 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 3078.6906
E= 100.00 Lum/m² n. fm
FACTORES DE REFLECION FLUJO LUMINOSO LOCAL
Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.3 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.67346 N N= 2
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

CUARTO DE MAQUINAS
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.80 m k K= 0.5804312
h(l  a )
ANCHO 3.50 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2004.3195
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.3 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.61118 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento
Fm= 0.8

BAÑO DEL ESTACIONAMIENTO


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 1.65 m k K= 0.2462687
h(l  a )
ANCHO 1.10 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 921.5069
100.0 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 665.00 Lumenes
Pared 0.3 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.2462 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

OFICINA
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 3.56 m k K= 1.1656174
h(l  a )
ANCHO 5.70 m
ALTURA 1.88 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 6089.1369
n. fm
E.S
T 
200.000 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 2900.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.833123 N N= 2
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

BAÑO DE LA OFICINA
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.12 m k K= 0.3888829
h(l  a )
ANCHO 2.05 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 1034.7816
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.3 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.52499 N N= 1
n. L
T
N
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

DORMITORIO 1
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 3.43 m k K= 0.5518428
h(l  a )
ANCHO 2.60 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2619.5348
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.638329 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

DORMITORIO 2
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.92 m k K= 0.5530442
h(l  a )
ANCHO 3.01 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2579.5235
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 2900.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.638868 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

CLOSET DEL DORMITORIO 2


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 0.90 m k K= 0.2610093
h(l  a )
ANCHO 3.14 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 1044.1915
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
N
n. L
T
Cu=n 0.50745 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

BAÑO DEL DORMITORIO 2


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 1.26 m k K= 0.2826847
h(l  a )
ANCHO 1.90 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 578.62985
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 665.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.51717 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

DORMITORIO 3
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.70 m k K= 0.5615366
h(l  a )
ANCHO 3.40 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10
NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL
Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2678.1963
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 2900.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.64269 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

BAÑO DEL DORMITORIO 3


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 1.90 m k K= 0.4096186
h(l  a )
ANCHO 2.60 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 1075.1696
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.574328 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

CLOSET DEL DORMITORIO 3


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 1.90 m k K= 0.3448971
h(l  a )
ANCHO 1.80 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 1176.1674
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.545203 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

BAÑO DELOS PASADISOS


DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 1.65 m k K= 0.3078358
h(l  a )
l.a
k
h(l  a )
ANCHO 1.65 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 643.8898
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 665.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.528526 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

LAVATORIO Y COCINA
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.35 m k K= 0.5965073
h(l  a )
ANCHO 5.00 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 3346.0378
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1
COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS
Tabla de coeficiente de utilizacion

T
Cu=n 0.658428 N N= 2
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

SALA Y COMEDOR
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 5.76 m k K= 1.0875298
h(l  a )
ANCHO 5.90 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 7794.4382
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.817506 N N= 4
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

TERRAZA
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 3.50 m k K= 0.5504502
h(l  a )
ANCHO 2.55 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 1749.4512
100.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.6377 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

PASADIZO
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 8.22 m k K= 0.3326642
h(l  a )
ANCHO 1.00 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2870.4538
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.536936 N N= 2
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8

ESCALERAS
DIMENSIONES DEL LOCAL O AREA A ILUMINAR INDICE DE LOCAL
l.a
LARGO 2.15 m k K= 0.4969621
h(l  a )
ANCHO 3.50 m
ALTURA 2.68 m k, es un numero comprendido entre 1 y 10

NIVEL DE ILUMINACION FLUJO LUMINOSO TOTAL


Según Norma EM.010 - RNE
E.S
E: Luminancia deseada T  Φt= 2299.3219
150.00 Lum/m² n. fm
E=

FACTORES DE REFLECION FLUJO LUMINOSO LOCAL


Tabla de Factores de reflexion
Del tipo de luminaria a utilizar
Techo 0.7 Blanco Φl= 1810.00 Lumenes
Pared 0.5 Medio cantidad de lamparas por luminaria
Piso 0.1 Oscuro n 1

COEFICIENTE DE UTILIZACION NUMERO DE LUMINARIAS


Tabla de coeficiente de utilizacion

T
Cu=n 0.613632 N N= 1
n. L
FACTOR DE MANTENIMIENTO
Tabla de factor de mantenimiento

Fm= 0.8
32
PRIMERA PLANTA
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
ESTACIONAMIENTO 13.8 5.7 5.56 0.6764 0.8 150
ESTACIONAMIENTO 2.91 5.7 2.68 0.67346 0.8 100
CUARTO MAQUINAS 2.8 3.5 2.68 0.61118 0.8 100
BAÑO ESTACIONAMIENTO 1.65 1.1 2.68 0.2462 0.8 100
OFICINA 3.56 5.7 1.88 0.833123 0.8 200
BAÑO DE LA OFICINA 2.12 2.05 2.68 0.52499 0.8 100
ESCALERA 2.15 3.5 2.68 0.613632 0.8 150
SEGUNDA PLANTA
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
DORMITORIO N° 1 3.43 2.6 2.68 0.638329 0.8 150
DORMITORIO N° 2 2.92 3.01 2.68 0.638868 0.8 150
CLOSET DORMITORIO N° 2 0.9 3.14 2.68 0.50745 0.8 150
BAÑO DORMITORIO N° 2 1.26 1.9 2.68 0.51717 0.8 100
DORMITORIO N° 3 2.7 3.4 2.68 0.64269 0.8 150
BAÑO DORMITORIO N° 3 1.9 2.6 2.68 0.574328 0.8 100
CLOSET DORMITORIO N° 3 1.9 1.8 2.68 0.545203 0.8 150
BAÑO GENERAL 1.65 1.65 2.68 0.528526 0.8 100
LAVATORIO Y COCINA 2.35 5 2.68 0.658428 0.8 150
SALA Y COMEDOR 5.76 5.9 2.68 0.817506 0.8 150
TERRAZA 3.5 2.55 2.68 0.6377 0.8 100
PASADIZOS 8.22 1 2.68 0.536936 0.8 150
ESCALERA 2.15 3.5 2.68 0.613632 0.8 150
TERCERA PLANTA
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
DORMITORIO N° 1 3.43 2.6 2.68 0.638329 0.8 150
DORMITORIO N° 2 2.92 3.01 2.68 0.638868 0.8 150
BAÑO DORMITORIO N° 2 0.9 3.14 2.68 0.50745 0.8 150
CLOSET DORMITORIO N° 2 1.26 1.9 2.68 0.51717 0.8 100
DORMITORIO N° 3 2.7 3.4 2.68 0.64269 0.8 150
BAÑO DORMITORIO N° 3 1.9 2.6 2.68 0.574328 0.8 100
CLOSET DORMITORIO N° 3 1.9 1.8 2.68 0.545203 0.8 150
BAÑO GENERAL 1.65 1.65 2.68 0.528526 0.8 100
LAVATORIO Y COCINA 2.35 5 2.68 0.658428 0.8 150
SALA Y COMEDOR 5.76 5.9 2.68 0.817506 0.8 150
TERRAZA 3.5 2.55 2.68 0.6377 0.8 100
PASADIZOS 8.22 1 2.68 0.536936 0.8 150
ESCALERA 2.15 3.5 2.68 0.613632 0.8 150
CUARTA PLANTA
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
DORMITORIO N° 1 3.43 2.6 2.68 0.638329 0.8 150
DORMITORIO N° 2 2.92 3.01 2.68 0.638868 0.8 150
BAÑO DORMITORIO N° 2 0.9 3.14 2.68 0.50745 0.8 150
CLOSET DORMITORIO N° 2 1.26 1.9 2.68 0.51717 0.8 100
DORMITORIO N° 3 2.7 3.4 2.68 0.64269 0.8 150
BAÑO DORMITORIO N° 3 1.9 2.6 2.68 0.574328 0.8 100
CLOSET DORMITORIO N° 3 1.9 1.8 2.68 0.545203 0.8 150
BAÑO GENERAL 1.65 1.65 2.68 0.528526 0.8 100
LAVATORIO Y COCINA 2.35 5 2.68 0.658428 0.8 150
SALA Y COMEDOR 5.76 5.9 2.68 0.817506 0.8 150
TERRAZA 3.5 2.55 2.68 0.6377 0.8 100
PASADIZOS 8.22 1 2.68 0.536936 0.8 150
ESCALERA 2.15 3.5 2.68 0.613632 0.8 150
QUINTA PLANTA
LARGO ANCHO ALTO
AMBIENTE Cu Fm E (Lum./m2)
(Metros) (Metros) (Metros)
DORMITORIO N° 1 3.43 2.6 2.68 0.638329 0.8 150
DORMITORIO N° 2 2.92 3.01 2.68 0.638868 0.8 150
BAÑO DORMITORIO N° 2 0.9 3.14 2.68 0.50745 0.8 150
CLOSET DORMITORIO N° 2 1.26 1.9 2.68 0.51717 0.8 100
DORMITORIO N° 3 2.7 3.4 2.68 0.64269 0.8 150
BAÑO DORMITORIO N° 3 1.9 2.6 2.68 0.574328 0.8 100
CLOSET DORMITORIO N° 3 1.9 1.8 2.68 0.545203 0.8 150
BAÑO GENERAL 1.65 1.65 2.68 0.528526 0.8 100
LAVATORIO Y COCINA 2.35 5 2.68 0.658428 0.8 150
SALA Y COMEDOR 5.76 5.9 2.68 0.817506 0.8 150
TERRAZA 3.5 2.55 2.68 0.6377 0.8 100
PASADIZOS 8.22 1 2.68 0.536936 0.8 150
ESCALERA 2.15 3.5 2.68 0.613632 0.8 150
ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
0.725512 1810.00 21804.7753 12
0.718836 1810.00 3078.69064 2
0.580431 1810.00 2004.31951 1
0.246269 665.00 921.506905 1
6089.137 2900.00 6089.1369 2
0.388883 1810.00 1034.78161 1
0.496962 1810.00 2299.32191 1 20

ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
0.551843 1810.00 2619.53475 1
0.553044 2900.00 2579.52347 1
0.261009 1810.00 1044.19155 1
0.282685 665.00 578.629851 1
0.561537 2900.00 2678.19633 1
0.409619 1810.00 1075.16959 1
0.344897 1810.00 1176.16741 1
0.307836 665.00 643.889799 1
0.596507 1810.00 3346.03784 2
1.08753 1810.00 7794.43821 4
0.55045 1810.00 1749.45115 1
0.332664 1810.00 2870.45383 2
0.496962 1810 2299.32191 1 18

ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
0.551843 1810 2619.53475 1
0.553044 2900 2579.52347 1
0.261009 1810 1044.19155 1
0.282685 665 578.629851 1
0.561537 2900 2678.19633 1
0.409619 1810 1075.16959 1
0.344897 1810 1176.16741 1
0.307836 665 643.889799 1
0.596507 1810 3346.03784 2
1.08753 1810 7794.43821 4
0.55045 1810 1749.45115 1
0.332664 1810 2870.45383 2
0.496962 1810 2299.32191 1 18

ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
0.551843 1810 2619.53475 1
0.553044 2900 2579.52347 1
0.261009 1810 1044.19155 1
0.282685 665 578.629851 1
0.561537 2900 2678.19633 1
0.409619 1810 1075.16959 1
0.344897 1810 1176.16741 1
0.307836 665 643.889799 1
0.596507 1810 3346.03784 2
1.08753 1810 7794.43821 4
0.55045 1810 1749.45115 1
0.332664 1810 2870.45383 2
0.496962 1810 2299.32191 1 18

ΦL ΦT N°
K (Lumenes) (Lumenes) LUMINARIAS
0.551843 1810 2619.53475 1
0.553044 2900 2579.52347 1
0.261009 1810 1044.19155 1
0.282685 665 578.629851 1
0.561537 2900 2678.19633 1
0.409619 1810 1075.16959 1
0.344897 1810 1176.16741 1
0.307836 665 643.889799 1
0.596507 1810 3346.03784 2
1.08753 1810 7794.43821 4
0.55045 1810 1749.45115 1
0.332664 1810 2870.45383 2
0.496962 1810 2299.32191 1 18
PRIMER PISO
TABLERO DISTRIBUCION 1
DESCRIPCION LARGO ANCHO AREA
ESTACIONAMIENTO 16.90 m 6.00 m 101.40 m²
CUARTO DE MAQUINAS 3.10 m 3.65 m 11.32 m²
SERVICIO HIGIENICO 3.10 m 2.35 m 7.29 m²
TOTAL 120.00 m²

CARGA
DESCRIPCION AREA POTENCIA
UNITARIA
ESTACIONAMIENTO 101.40 m² 25.00 w/m² 2535.00 W
CUARTO DE MAQUINAS 11.32 m² 25.00 w/m² 282.88 W
SERVICIO HIGIENICO 7.29 m² 25.00 w/m² 182.13 W
TOTAL 3000.00 W

CUADRO DE CARGAS DEL TD1


DESCRIPCION PI (W) FD (%) MD (W)
2000.00 W 100% 2000.00 W
LUMINARIAS
1000.00 W 35% 350.00 W
TELEVISORES 350.00 W 100% 350.00 W
DVD 250.00 W 100% 250.00 W
TOTAL 2950.00 W

EN LA SIGUIENTE TABLA CALCULAREMOS LAS CORRIENTES DE DISEÑO


AGREGANDO SUS FACTORES DE SEGURIDAD PARA LA ELECCION DE LA
LLAVE TERMOMAGNETICA ADECUADA

VOLTAJE 220
F.P 1

DIAGRAMA UNIFILIAR
DESCRIPCION POTENCIA CORRIENTE F.D CORRIENTE DISEÑO
ALUMBRADO 2350.00 W 10.68 A 1.15 12.28 A
TOMACORRIENTE 600.00 W 2.73 A 1.15 3.14 A
RESERVA

MAXIMA DEMANDA - CUADRO DE CARGAS


TABLERO DE POTENCIA MAXIMA
DISTRIBUCION INSTALADA DEMANDA
TD - 1 3600.00 W 2950.00 W
TD - 2 1898.25 W 1898.25 W
TD - 3 17370.43 W 14567.05 W
TD - 4 15370.43 W 14567.05 W
TD - 5 14196.00 W 14567.05 W
TD - 6 13846.00 W 14567.05 W
TOTAL 63116.45 W

TABLERO DE CORREIENTE
CIRCUITOS TIPO DE CARGAS
DISTRIBUCION ELECTRICA
C-1 ALUMBRADO 12.28 A
TD - 1 C-2 TOMACORRIENTE 3.14 A
C-3 RESERVA 6.82 A
C-1 ALUMBRADO 5.51 A
C-2 ALUMBRADO 5.51 A
TD - 2
C-3 TOMACORRIENTE 6.14 A
C -4 RESERVA 6.82 A
C-1 ALUMBRADO 12.60 A
C-2 ALUMBRADO 12.60 A
C-3 TOMACORRIENTE 16.99 A
C -4 TOMACORRIENTE 16.99 A
TD - 3
C-5 COCINA ELECTRICA 39.27 A
C-6 LAVADORA 10,80
C -7 ELECTROBOMBA 7.80 A
C-8 RESERVA 6.82 A
C-1 ALUMBRADO 12.60 A
C-2 ALUMBRADO 12.60 A
C-3 TOMACORRIENTE 16.99 A
C -4 TOMACORRIENTE 16.99 A
TD - 4
C-5 COCINA ELECTRICA 39.27 A
C-6 LAVADORA 10,80
C -7 ELECTROBOMBA 7.80 A
C-8 RESERVA 6.82 A
C-1 ALUMBRADO 12.60 A

TD - 5
C-2 ALUMBRADO 12.60 A
C-3 TOMACORRIENTE 16.99 A
C -4 TOMACORRIENTE 16.99 A
TD - 5
C-5 COCINA ELECTRICA 39.27 A
C-6 LAVADORA 10,80
C -7 ELECTROBOMBA 7.80 A
C-8 RESERVA 6.82 A
C-1 ALUMBRADO 12.60 A
C-2 ALUMBRADO 12.60 A
C-3 TOMACORRIENTE 16.99 A
C -4 TOMACORRIENTE 16.99 A
TD - 6
C-5 COCINA ELECTRICA 39.27 A
C-6 LAVADORA 10,80
C -7 ELECTROBOMBA 7.80 A
C-8 RESERVA 6.82 A

K: Factor independiente del suministro


K=1 monofasica
K=1.73 trifasica
COSφ Factor de potencia para luminarias se tomara 1

El calibre minimo de los conductores aceptado en instalaciones de interiores sera:


Instalaciones de energia electrica en general 2.5 mm2 0 N° 14 AWG para luminacion.
Instalaciones de energia electrica en general 4 mm2 0 N° 12 AWG para Tomacorrientes.
MER PISO
TABLERO DISTRIBUCION 2
DESCRIPCION LARGO ANCHO AREA
OFICINA 3.54 m 6.00 m 21.23 m²
SERVICIO HIGIENICO 2.45 m 2.35 m 5.76 m²
ESCALERAS 2.45 m 3.65 m 8.94 m²
TOTAL 35.93 m²

CARGA
DESCRIPCION AREA POTENCIA
UNITARIA
OFICINA 21.23 m² 25.00 w/m² 530.75 W
SERVICIO HIGIENICO 5.76 m² 25.00 w/m² 143.94 W
ESCALERAS 8.94 m² 25.00 w/m² 223.56 W
TOTAL 898.25 W

CUADRO DE CARGAS DEL TD2


DESCRIPCION PI (W) FD (%) MD (W)
898.25 W 100% 898.25 W
LUMINARIAS
0.00 W 35% 0.00 W
COMPUTADORAS 350.00 W 100% 350.00 W
VENTILADOR 300.00 W 100% 300.00 W
TELEVISOR 350.00 W 100% 350.00 W
TOTAL 1898.25 W

EN LA SIGUIENTE TABLA CALCULAREMOS LAS CORRIENTES DE


DISEÑO AGREGANDO SUS FACTORES DE SEGURIDAD PARA LA
ELECCION DE LA LLAVE TERMOMAGNETICA ADECUADA

VOLTAJE 220
F.P 1

20 A DIAGRAMA UNIFILIAR
CORRIENTE
0.42 DESCRIPCION POTENCIA CORRIENTE F.D DISEÑO
C1 ALUMBRADO 898.25 W 4.08 1.15 4.70
C2 TOMACORRIENTE 1000.00 W 4.55 1.15 5.23

1HP

ITM A
UTILIZAR
20.00 A LLAVES
10.00 A 100.00 10 10
10.00 A 500.00 20 25
10.00 A 160.00 40 4
10.00 A 30 30 1
10.00 A 360 90 4 C1-2
10.00 A C3-4
20.00 A C5
20.00 A C6
20.00 A C7
20.00 A
40.00 A
20.00 A
20.00 A
10.00 A
20.00 A
20.00 A
20.00 A
20.00 A
40.00 A
20.00 A
20.00 A
10.00 A
20.00 A
20.00 A
20.00 A
20.00 A
40.00 A
20.00 A
20.00 A
10.00 A
20.00 A
20.00 A
20.00 A
20.00 A
40.00 A
20.00 A
20.00 A
10.00 A

interiores sera:
para luminacion.
ara Tomacorrientes.
SEGUNDO PISO TERCER
TABLERO DISTRIBUCION 3 TABLERO DISTR
DESCRIPCION LARGO ANCHO AREA DESCRIPCION
DORMITORIO 1 4.08 m 2.90 m 11.81 m² DORMITORIO 1
DORMITORIO 2 3.17 m 3.35 m 10.63 m² DORMITORIO 2
BAÑO DORMITORIO 2 1.41 m 1.90 m 2.68 m² BAÑO DORMITORIO 2
CLOSET DORMITORIO 2 0.90 m 3.30 m 2.97 m² CLOSET DORMITORIO 2
DORMITORIO 3 2.85 m 3.55 m 10.12 m² DORMITORIO 3
BAÑO DORMITORIO 3 1.95 m 2.75 m 5.36 m² BAÑO DORMITORIO 3
CLOSET DORMITORIO 3 2.96 m 2.10 m 6.22 m² CLOSET DORMITORIO 3
BAÑO DE PASADISOS 1.95 m 1.80 m 3.51 m² BAÑO DE PASADISOS
LAVANDERIA Y COCINA 2.50 m 5.35 m 13.38 m² LAVANDERIA Y COCINA
SALA COMEDOR 5.77 m 6.20 m 35.76 m² SALA COMEDOR
TERRAZA 2.45 m 2.70 m 6.62 m² TERRAZA
PASADISO 8.20 m 1.05 m 8.61 m² PASADISO
ESCALERAS 2.45 m 3.80 m 9.31 m² ESCALERAS
TOTAL 126.98 m² TOTAL

CARGA
DESCRIPCION AREA POTENCIA DESCRIPCION
UNITARIA
DORMITORIO 1 11.81 m² 25.00 w/m² 295.29 W DORMITORIO 1
DORMITORIO 2 10.63 m² 25.00 w/m² 265.83 W DORMITORIO 2
BAÑO DORMITORIO 2 2.68 m² 25.00 w/m² 67.02 W BAÑO DORMITORIO 2
CLOSET DORMITORIO 2 2.97 m² 25.00 w/m² 74.23 W CLOSET DORMITORIO 2
DORMITORIO 3 10.12 m² 25.00 w/m² 252.94 W DORMITORIO 3
BAÑO DORMITORIO 3 5.36 m² 25.00 w/m² 134.06 W BAÑO DORMITORIO 3
CLOSET DORMITORIO 3 6.22 m² 25.00 w/m² 155.47 W CLOSET DORMITORIO 3
BAÑO DE PASADISOS 3.51 m² 25.00 w/m² 87.75 W BAÑO DE PASADISOS
LAVANDERIA Y COCINA 13.38 m² 25.00 w/m² 334.38 W LAVANDERIA Y COCINA
SALA COMEDOR 35.76 m² 25.00 w/m² 894.09 W SALA COMEDOR
TERRAZA 6.62 m² 25.00 w/m² 165.38 W TERRAZA
PASADISO 8.61 m² 25.00 w/m² 215.25 W PASADISO
ESCALERAS 9.31 m² 25.00 w/m² 232.75 W ESCALERAS
TOTAL 3174.43 W TOTAL

CUADRO DE CARGAS DEL TD3 CUADRO DE CAR


DESCRIPCION PI (W) FD (%) MD (W) DESCRIPCION
2000.00 W 100% 2000.00 W
LUMINARIAS LUMINARIAS
1174.43 W 35% 411.05 W
COMPUTADORAS 350.00 W 100% 350.00 W COMPUTADORAS
VENTILADOR 300.00 W 100% 300.00 W VENTILADOR
TELEVISOR 350.00 W 100% 350.00 W TELEVISOR
LICUADORA 500.00 W 100% 500.00 W LICUADORA
FRIGIDER 600.00 W 100% 600.00 W FRIGIDER
PLANCHA 1000.00 W 100% 1000.00 W PLANCHA
EQUIPO DE SONIDO 150.00 W 100% 150.00 W EQUIPO DE SONIDO
COCINA ELECTRICA 8000.00 W 80% 6400.00 W COCINA ELECTRICA
LAVADORA 2200.00 W 80% 1760.00 W LAVADORA
ELECTROBOMBA 746.00 W 100% 746.00 W ELECTROBOMBA
TOTAL 14567.05 W TOTAL

EN LA SIGUIENTE TABLA CALCULAREMOS LAS CORRIENTES DE EN LA SIGUIENTE TABLA CALCULA


DISEÑO AGREGANDO SUS FACTORES DE SEGURIDAD PARA LA DISEÑO AGREGANDO SUS FACTO
ELECCION DE LA LLAVE TERMOMAGNETICA ADECUADA ELECCION DE LA LLAVE TERM

VOLTAJE 220 VOLTAJE


F.P 1 F.P

DIAGRAMA UNIFILIAR DIAGR


DESCRIPCION POTENCIA CORRIENTE F.D CORRIENTE DESCRIPCION
ALUMBRADO 2411.05 W 10.96 1.15 12.60 ALUMBRADO
TOMACORRIENTE 3250.00 W 14.77 1.15 16.99 TOMACORRIENTE
COCINA ELECTRICA 6400.00 W 29.09 1.35 39.27 COCINA ELECTRICA
LAVADORA 1760.00 W 8.00 1.35 10.80 LAVADORA
ELECTROBOMBA 746.00 W 3.39 2.30 7.80 ELECTROBOMBA
TERCER PISO CUARTO PISO
TABLERO DISTRIBUCION 4 TABLERO DISTRIBUCION 5
DESCRIPCION LARGO ANCHO AREA DESCRIPCION
ORMITORIO 1 4.08 m 2.90 m 11.81 m² DORMITORIO 1
ORMITORIO 2 3.17 m 3.35 m 10.63 m² DORMITORIO 2
AÑO DORMITORIO 2 1.41 m 1.90 m 2.68 m² BAÑO DORMITORIO 2
LOSET DORMITORIO 2 0.90 m 3.30 m 2.97 m² CLOSET DORMITORIO 2
ORMITORIO 3 2.85 m 3.55 m 10.12 m² DORMITORIO 3
AÑO DORMITORIO 3 1.95 m 2.75 m 5.36 m² BAÑO DORMITORIO 3
LOSET DORMITORIO 3 2.96 m 2.10 m 6.22 m² CLOSET DORMITORIO 3
AÑO DE PASADISOS 1.95 m 1.80 m 3.51 m² BAÑO DE PASADISOS
AVANDERIA Y COCINA 2.50 m 5.35 m 13.38 m² LAVANDERIA Y COCINA
ALA COMEDOR 5.77 m 6.20 m 35.76 m² SALA COMEDOR
ERRAZA 2.45 m 2.70 m 6.62 m² TERRAZA
ASADISO 8.20 m 1.05 m 8.61 m² PASADISO
SCALERAS 2.45 m 3.80 m 9.31 m² ESCALERAS
TOTAL 126.98 m² TOTAL

CARGA
DESCRIPCION AREA POTENCIA DESCRIPCION
UNITARIA
ORMITORIO 1 11.81 m² 25.00 w/m² 295.29 W DORMITORIO 1
ORMITORIO 2 10.63 m² 25.00 w/m² 265.83 W DORMITORIO 2
AÑO DORMITORIO 2 2.68 m² 25.00 w/m² 67.02 W BAÑO DORMITORIO 2
LOSET DORMITORIO 2 2.97 m² 25.00 w/m² 74.23 W CLOSET DORMITORIO 2
ORMITORIO 3 10.12 m² 25.00 w/m² 252.94 W DORMITORIO 3
AÑO DORMITORIO 3 5.36 m² 25.00 w/m² 134.06 W BAÑO DORMITORIO 3
LOSET DORMITORIO 3 6.22 m² 25.00 w/m² 155.47 W CLOSET DORMITORIO 3
AÑO DE PASADISOS 3.51 m² 25.00 w/m² 87.75 W BAÑO DE PASADISOS
AVANDERIA Y COCINA 13.38 m² 25.00 w/m² 334.38 W LAVANDERIA Y COCINA
ALA COMEDOR 35.76 m² 25.00 w/m² 894.09 W SALA COMEDOR
ERRAZA 6.62 m² 25.00 w/m² 165.38 W TERRAZA
ASADISO 8.61 m² 25.00 w/m² 215.25 W PASADISO
SCALERAS 9.31 m² 25.00 w/m² 232.75 W ESCALERAS
TOTAL 3174.43 W TOTAL

CUADRO DE CARGAS DEL TD3 CUADRO DE CARGAS DEL TD3


DESCRIPCION PI (W) FD (%) MD (W) DESCRIPCION
2000.00 W 100% 2000.00 W
UMINARIAS LUMINARIAS
1174.43 W 35% 411.05 W
OMPUTADORAS 350.00 W 100% 350.00 W COMPUTADORAS
ENTILADOR 300.00 W 100% 300.00 W VENTILADOR
ELEVISOR 350.00 W 100% 350.00 W TELEVISOR
ICUADORA 500.00 W 100% 500.00 W LICUADORA
RIGIDER 600.00 W 100% 600.00 W FRIGIDER
LANCHA 1000.00 W 100% 1000.00 W PLANCHA
QUIPO DE SONIDO 150.00 W 100% 150.00 W EQUIPO DE SONIDO
OCINA ELECTRICA 8000.00 W 80% 6400.00 W COCINA ELECTRICA
AVADORA 2200.00 W 80% 1760.00 W LAVADORA
LECTROBOMBA 746.00 W 100% 746.00 W ELECTROBOMBA
TOTAL 14567.05 W TOTAL

EN LA SIGUIENTE TABLA CALCULAREMOS LAS CORRIENTES DE EN LA SIGUIENTE TABLA CALCULAREMOS LAS


DISEÑO AGREGANDO SUS FACTORES DE SEGURIDAD PARA LA DISEÑO AGREGANDO SUS FACTORES DE SEGU
ELECCION DE LA LLAVE TERMOMAGNETICA ADECUADA ELECCION DE LA LLAVE TERMOMAGNETICA

220 VOLTAJE 220


1 F.P 1

DIAGRAMA UNIFILIAR DIAGRAMA UNIFILI


DESCRIPCION POTENCIA CORRIENTE F.D CORRIENTE DESCRIPCION
LUMBRADO 2411.05 W 10.96 1.15 12.60 ALUMBRADO
OMACORRIENTE 3250.00 W 14.77 1.15 16.99 TOMACORRIENTE
OCINA ELECTRICA 6400.00 W 29.09 1.35 39.27 COCINA ELECTRICA
AVADORA 1760.00 W 8.00 1.35 10.80 LAVADORA
LECTROBOMBA 746.00 W 3.39 2.30 7.80 ELECTROBOMBA
CUARTO PISO QUINTO PISO
TABLERO DISTRIBUCION 5 TABLERO DISTRIBUCION 6
LARGO ANCHO AREA DESCRIPCION LARGO
4.08 m 2.90 m 11.81 m² DORMITORIO 1 4.08 m
3.17 m 3.35 m 10.63 m² DORMITORIO 2 3.17 m
1.41 m 1.90 m 2.68 m² BAÑO DORMITORIO 2 1.41 m
0.90 m 3.30 m 2.97 m² CLOSET DORMITORIO 2 0.90 m
2.85 m 3.55 m 10.12 m² DORMITORIO 3 2.85 m
1.95 m 2.75 m 5.36 m² BAÑO DORMITORIO 3 1.95 m
2.96 m 2.10 m 6.22 m² CLOSET DORMITORIO 3 2.96 m
1.95 m 1.80 m 3.51 m² BAÑO DE PASADISOS 1.95 m
2.50 m 5.35 m 13.38 m² LAVANDERIA Y COCINA 2.50 m
5.77 m 6.20 m 35.76 m² SALA COMEDOR 5.77 m
2.45 m 2.70 m 6.62 m² TERRAZA 2.45 m
8.20 m 1.05 m 8.61 m² PASADISO 8.20 m
2.45 m 3.80 m 9.31 m² ESCALERAS 2.45 m
TOTAL 126.98 m² TOTAL

CARGA
AREA POTENCIA DESCRIPCION AREA
UNITARIA
11.81 m² 25.00 w/m² 295.29 W DORMITORIO 1 11.81 m²
10.63 m² 25.00 w/m² 265.83 W DORMITORIO 2 10.63 m²
2.68 m² 25.00 w/m² 67.02 W BAÑO DORMITORIO 2 2.68 m²
2.97 m² 25.00 w/m² 74.23 W CLOSET DORMITORIO 2 2.97 m²
10.12 m² 25.00 w/m² 252.94 W DORMITORIO 3 10.12 m²
5.36 m² 25.00 w/m² 134.06 W BAÑO DORMITORIO 3 5.36 m²
6.22 m² 25.00 w/m² 155.47 W CLOSET DORMITORIO 3 6.22 m²
3.51 m² 25.00 w/m² 87.75 W BAÑO DE PASADISOS 3.51 m²
13.38 m² 25.00 w/m² 334.38 W LAVANDERIA Y COCINA 13.38 m²
35.76 m² 25.00 w/m² 894.09 W SALA COMEDOR 35.76 m²
6.62 m² 25.00 w/m² 165.38 W TERRAZA 6.62 m²
8.61 m² 25.00 w/m² 215.25 W PASADISO 8.61 m²
9.31 m² 25.00 w/m² 232.75 W ESCALERAS 9.31 m²
TOTAL 3174.43 W TOTAL

CUADRO DE CARGAS DEL TD3 CUADRO DE CARGAS DEL TD3


PI (W) FD (%) MD (W) DESCRIPCION PI (W)
2000.00 W 100% 2000.00 W 2000.00 W
LUMINARIAS
1174.43 W 35% 411.05 W 1174.43 W
350.00 W 100% 350.00 W COMPUTADORAS 350.00 W
300.00 W 100% 300.00 W VENTILADOR 300.00 W
350.00 W 100% 350.00 W TELEVISOR 350.00 W
500.00 W 100% 500.00 W LICUADORA 500.00 W
600.00 W 100% 600.00 W FRIGIDER 600.00 W
1000.00 W 100% 1000.00 W PLANCHA 1000.00 W
150.00 W 100% 150.00 W EQUIPO DE SONIDO 150.00 W
8000.00 W 80% 6400.00 W COCINA ELECTRICA 8000.00 W
2200.00 W 80% 1760.00 W LAVADORA 2200.00 W
746.00 W 100% 746.00 W ELECTROBOMBA 746.00 W
TOTAL 14567.05 W TOTAL

ENTE TABLA CALCULAREMOS LAS CORRIENTES DE EN LA SIGUIENTE TABLA CALCULAREMOS LAS CORRIENTES
EGANDO SUS FACTORES DE SEGURIDAD PARA LA DISEÑO AGREGANDO SUS FACTORES DE SEGURIDAD PARA
N DE LA LLAVE TERMOMAGNETICA ADECUADA ELECCION DE LA LLAVE TERMOMAGNETICA ADECUADA

VOLTAJE 220
F.P 1

DIAGRAMA UNIFILIAR DIAGRAMA UNIFILIAR


POTENCIA CORRIENTE F.D CORRIENTE DESCRIPCION POTENCIA
2411.05 W 10.96 1.15 12.60 ALUMBRADO 2411.05 W
3250.00 W 14.77 1.15 16.99 TOMACORRIENTE 3250.00 W
6400.00 W 29.09 1.35 39.27 COCINA ELECTRICA 6400.00 W
1760.00 W 8.00 1.35 10.80 LAVADORA 1760.00 W
746.00 W 3.39 2.30 7.80 ELECTROBOMBA 746.00 W
INTO PISO
O DISTRIBUCION 6
ANCHO AREA
2.90 m 11.81 m²
3.35 m 10.63 m²
1.90 m 2.68 m²
3.30 m 2.97 m²
3.55 m 10.12 m²
2.75 m 5.36 m²
2.10 m 6.22 m²
1.80 m 3.51 m²
5.35 m 13.38 m²
6.20 m 35.76 m²
2.70 m 6.62 m²
1.05 m 8.61 m²
3.80 m 9.31 m²
AL 126.98 m²

CARGA POTENCIA
UNITARIA
25.00 w/m² 295.29 W
25.00 w/m² 265.83 W
25.00 w/m² 67.02 W
25.00 w/m² 74.23 W
25.00 w/m² 252.94 W
25.00 w/m² 134.06 W
25.00 w/m² 155.47 W
25.00 w/m² 87.75 W
25.00 w/m² 334.38 W
25.00 w/m² 894.09 W
25.00 w/m² 165.38 W
25.00 w/m² 215.25 W
25.00 w/m² 232.75 W
AL 3174.43 W

DE CARGAS DEL TD3


FD (%) MD (W)
100% 2000.00 W
35% 411.05 W
100% 350.00 W
100% 300.00 W
100% 350.00 W
100% 500.00 W
100% 600.00 W
100% 1000.00 W
100% 150.00 W
80% 6400.00 W
80% 1760.00 W
100% 746.00 W
AL 14567.05 W

ALCULAREMOS LAS CORRIENTES DE


S FACTORES DE SEGURIDAD PARA LA
TERMOMAGNETICA ADECUADA

DIAGRAMA UNIFILIAR
CORRIENTE F.D CORRIENTE
10.96 1.15 12.60
14.77 1.15 16.99
29.09 1.35 39.27
8.00 1.35 10.80
3.39 2.30 7.80
MD Δ𝑉=((𝐾)(𝐼𝐷)(𝜹) 〖 (cos 〗⁡〖� )(𝐿) 〗 )/�
i=
K.V.cosφ

MAXIMA
DESCRIPCION CORRIENTE
DEMANDA
Seccion del conductor alimentador 4848.25 w 22.04 A
Medidor 1 tablero de distribucion 1,2
Seccion del conductor alimentador 14567.05 w 66.21 A
Medidor 2 tablero de distribucion 3
Seccion del conductor alimentador 14567.05 w 66.21 A
Medidor 3 tablero de distribucion 4
Seccion del conductor alimentador 14567.05 w 66.21 A
Medidor 4 tablero de distribucion 5
Seccion del conductor alimentador 14567.05 w 66.21 A
Medidor 5 tablero de distribucion 6
Seccion del conductor de la cocina 6400.00 w 29.09 A
electrica
Seccion del conductor de la lavadora 1760.00 w 8.00 A
electrica
Seccion del conductor de la 746.00 w 3.39 A
electrobomba

DESCRIPCION CORRIENTE DISEÑO LONGITUD

Caida de tension del conductor


alimentador Medidor 1 tablero de 29.75 A 8.00 m
distribucion 1, 2

Caida de tension del conductor


alimentador Medidor 2 tablero de 89.39 A 12.00 m
distribucion 3

Caida de tension del conductor


alimentador Medidor 3 tablero de 89.39 A 15.00 m
distribucion 4

Caida de tension del conductor


alimentador Medidor 4 tablero de 89.39 A 17.00 m
distribucion 5

Caida de tension del conductor


alimentador Medidor 5 tablero de 89.39 A 20.00 m
distribucion 6
Caida de tension del conductor
alimentador Medidor 5 tablero de 89.39 A 20.00 m
distribucion 6

Caida de tension del conductor de la 39.27 A 10.00 m


cocina electrica

Caida de tension del conductor de la 10.80 A 10.00 m


lavadora electrica

Caida de tension del conductor de la 7.80 A 25.00 m


electrobomba
(cos 〗⁡〖� )(𝐿) 〗 )/�

CORRIENTE SECCION DEL


F.D DISEÑO CONDUCTOR

1.35 29.75 A 6 mm2 o


10 AWG
10 mm2 o
1.35 89.39 A 8 AWG
10 mm2 o
1.35 89.39 A 8 AWG
10 mm2 o
1.35 89.39 A 8 AWG

1.35 89.39 A 10 mm2 o


8 AWG
6 mm2 o
1.35 39.27 A 10 AWG
4 mm2 o
1.35 10.80 A 12 AWG
4 mm2 o
2.3 7.80 A 12 AWG

SECCION DEL CAIDA DE


CONDUCTOR TENSION ΔV

6.00 mm² 0.69 V

10.00 mm² 1.88 V

10.00 mm² 2.35 V

10.00 mm² 2.66 V

10.00 mm² 3.13 V


10.00 mm² 3.13 V

6.00 mm² 1.15 V

4.00 mm² 0.47 V

4.00 mm² 0.85 V