GAN-TRIUMPH “ODME” OPERATION & TEST PROCEDURE

CAUTION : System must be always on. Do not turn the system off. It can cause memory loss.

OIL DISCHARGE PROCEDURE

A) Preparations on Main Deck


1-Be sure that ; ``A1`` ( Fresh water drain) , ``C1`` ( Sample inlet drain) , ``D1 & D2``( Sample outlet
drain) , ``E`` ( Sampling pump Drain) valves are closed.

2- Open ``A`` (Fresh water inlet), ``C`` (Sample Inlet), ``D`` (Sample outlet-return to slop) valves.

3- Open the doors on the side of VPC panel

1/5
GAN-TRIUMPH “ODME” OPERATION & TEST PROCEDURE

B) Preparations at Fire Control Station.

1- Open ``B`` (Air supply of VPC panel) valve.

2- Be sure that the switch at pump control panel is at ``1`` position & Flowmeter panel power supply
is on.

2/5
GAN-TRIUMPH “ODME” OPERATION & TEST PROCEDURE
C ) Preparations at CCR

1- Push enter button for Oil Discharge option and select oil type

2- Reset Oil disch. Acc.

3- Set Total oil disch alarm limit (This limit must be max. 1/30,000 of the last cargo)

4- Select Start oil discharge option. When you push enter button system will start flushing and
calibration. This process takes 3 minutes. At the last 1.5 minutes start Slop P pump with 50 bars at
the end of the flushing process overboard will open and return to slop valve will be closed

5- When decanting completed. Push enter button twice Overboard valve will close and return valve
will open.
3/5
GAN-TRIUMPH “ODME” OPERATION & TEST PROCEDURE

TEST PROCEDURE

Before testing same procedure must be followed like decanting on deck. Only Sampling Valve (C)
and Sample outlet valve (D) to be kept closed.

1- From General settings menu Choose flowmeter 1 as manual (Manual Value is 500 cbm/hr)

2- General settings menu Choose Speed as manual (Manual Value is 10 kts)

3- At the bottom of General settings menu save the changes.

4/5
GAN-TRIUMPH “ODME” OPERATION & TEST PROCEDURE

4- Choose System Test option under Service Menu and Self Test

5- Select self test. System will test all sensors commands itself and result will be displayed.

6- Select simulation mode. When you select simulation mode overboard valve will open and return to
slop valve will close.

7- Push up button to increase PPM manually. When you reach 30L/mile System will give PPM Alarm
and overboard valve will close and Return to slop will open.

5/5