Sei sulla pagina 1di 2

Dacon MFL Series 2.

0
8" Datasheet - Magnetic Flux Leakage Metal Loss Inspection Tool

Mechanical Properties Measurement Properties

Nominal Pipe Size 8 inch Number of Metal Loss Sensors 80 tri-axial hall effect

Minimum ID Straight Pipe 180 mm Circumferential Hall Sensor Sapcing 6 mm

Minimum ID Bend 200 mm Axial Sampling Frequency, Variable 1,000 Hz

Tool Length 2,010 mm Minimum Wall Thickness 4 mm

Tool Weight 86 kgs Maximum Wall Thickness 16 mm

Minimum Bend Radius/ Degree 1.5D / 90° Direction of Magnetization Axial

Minimum Bend to Bend Distance 305 mm Internal/ External Discrimination Eddy current based

Inspection Distance 180 (@1m/s) kms Pressure Measurement Accuracy +/- 1.0 barg

Battery Life 50.0 hours Temperature Measurement Accuracy +/- 2.0 ℃

Number of Tool Bodies 4

General Operating Conditions Tool Operating Conditions

Minimum Pressure 2 barg Maximum Tool Speed 3 m/sec

Maximum Operating Pressure 50 barg Minimum Tool Speed 0.3 m/sec

Temperature Range 0 - 70 °C Min Distance Between T Openings 305 mm

Min Differential Pressure at Launch 2 barg Bidirectional No

Min Diff Pressure During Inspection 2 barg Trackable with Pinger Yes

IMU Installation No

Launcher and Receiver Dimensions Recommended Dimension Launcher Receiver

A (mm) 2,215 2,520

B (mm) 305 2,215

C (inch) 10 10

D (inch) 8 8

E (mm) 178 178

F (mm) 2,010 2,010


Dacon MFL Series 2.0
8" Datasheet - Magnetic Flux Leakage Metal Loss Inspection Tool

Mechanical Properties Measurement Properties

Nominal Pipe Size 18 inch Number of Metal Loss Sensors 190 tri-axial hall effect

Minimum ID Straight Pipe 360 mm Circumferential Hall Sensor Sapcing 6 mm

Minimum ID Bend 395 mm Axial Sampling Frequency, Variable 1,000 Hz

Tool Length 1,740 mm Minimum Wall Thickness 4 mm

Tool Weight 370 kgs Maximum Wall Thickness 16 mm

Minimum Bend Radius/ Degree 1.5D / 90° Direction of Magnetization Axial

Minimum Bend to Bend Distance 686 mm Internal/ External Discrimination Eddy current based

Inspection Distance 489.6 (@1m/s) kms Pressure Measurement Accuracy +/- 1 barg

Battery Life 136.0 hours Temperature Measurement Accuracy +/- 2 ℃

Number of Tool Bodies 2

General Operating Conditions Tool Operating Conditions

Minimum Pressure 2 barg Maximum Tool Speed 3 m/sec

Maximum Operating Pressure 50 barg Minimum Tool Speed 0.3 m/sec

Temperature Range 0 - 70 °C Min Distance Between T Openings 686 mm

Min Differential Pressure at Launch 2 barg Bidirectional No

Min Diff Pressure During Inspection 2 barg Trackable with Pinger Yes

IMU Installation Yes

Launcher and Receiver Dimensions Recommended Dimension Launcher Receiver

A (mm) 2,700 3,400

B (mm) 686 2,700

C (inch) 22 22

D (inch) 18 18

E (mm) 508 508

F (mm) 1,740 1,740

Potrebbero piacerti anche