Sei sulla pagina 1di 5

Table 7.21.

1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 1

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-1: Theaters and other facilities for the viewing of 100 or less 2 2 1 1 1 per 1
(A) the performing arts or motion pictures, 101 - 200 add 1 add 1 add 1 add 1 500 service
typically with fixed seats. 201 - 300 add 1 add 2 add 0 add 1 people sink
ea. add'l 300 add 1 add 2 add 1 add 1 per floor
See Notes: (6), (9) over 300 (21)

A-2: Night clubs, bars, taverns, and similar 25 or less 1 1 1 1 1 per 1


facilities where drink and/or food is consumed. 26 - 50 add 1 add 1 add 1 add 1 250 service
51 - 100 add 1 add 1 add 1 add 1 people sink
See Notes: (2), (3), (6), (9), (13) ea. add'l 200 add 1 add 1 add 1 add 1 (2) per floor
over 100 (21)

A-2: Restaurants, banquet halls, food courts, 50 or less 1 1 1 1 1 per 1


carry-outs with seating. 51 - 100 add 1 add 1 add 1 add 1 250 service
101 - 200 add 1 add 1 add 0 add 0 people sink
See Notes: (2), (3), (6), (9), (13) 201 - 300 add 1 add 1 add 1 add 1 (2) per floor
ea. add'l 200 add 1 add 1 add 1 add 1 (21)
over 300

A-3: Museums, art galleries, exhibition halls, 50 or less 1 1 1 1 1 per 1


lecture halls, libraries. 51 - 150 add 1 add 1 add 1 add 1 500 service
151 - 300 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9) ea. add'l 300 add 1 add 1 add 1 add 1 per floor
over 300 (21)

A-3: Passenger terminals, transportation facilities. 100 or less 1 1 1 1 1 per 1


101 to 250 add 2 add 2 add 1 add 1 500 service sink
See Notes: (6), (9) ea. add'l 250 add 2 add 2 add 1 add 1 people per floor
over 250 (21)

A-3: Places of worship and other religious services. 25 or less 1 1 1 1 1 per 1


26 - 150 add 1 add 1 add 1 add 1 500 service sink
See Notes: (6), (9) ea. add'l 150 add 1 add 1 add 1 add 1 people per floor
over 150 (21)

A-3: Gymnasiums (without spectator seating), 50 or less 1 1 1 1 1 per 1


health spas. 51 - 100 add 1 add 1 add 1 add 1 200 service
101 - 200 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9), (20) ea. add'l 200 add 2 add 2 add 2 add 2 per floor
over 200 (21)
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 2

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-4: Coliseums, arenas, skating rinks, pools and 1 - 100 2 2 2 2 1 per 1
(A) tennis courts for indoor sporting events and 101 - 200 add 2 add 2 add 2 add 2 500 service
(continued) activities. 201 - 400 add 2 add 2 add 2 add 2 people sink
ea. add'l 400 add 2 add 4 add 1 add 2 per floor
See Notes: (6), (9), (20) up to 2600 (21)
ea. add'l 600 add 2 add 4 add 1 add 2
over 2600

A-5: Stadiums, amusement parks, bleachers and 1 - 100 2 2 2 2 1 per 1


grandstands for outdoor sporting events and 101 - 200 add 2 add 2 add 2 add 2 1000 service
activities. 201 - 400 add 2 add 2 add 2 add 2 people sink
ea. add'l 400 add 2 add 4 add 1 add 2 per floor
See Notes: (6), (9), (20) up to 2600 (21)
ea. add'l 600 add 2 add 4 add 1 add 2
over 2600

Business B: Buildings for the transaction of business, 1 - 15 1 1 1 1 1 per 1


(B) professional services, office buildings, banks, 16 - 50 add 1 add 1 add 0 add 0 100 service
and similar uses. ea. add'l 50 add 1 add 1 add 1 add 1 people sink
over 50 per floor
See Notes: (6), (9), (12), (15) (21)

Education E-1: Day Care, Preschool, Kindergarten 15 or less 1 1 1 1 1 per 1


(E) 16 - 30 add 1 add 1 add 1 add 1 100 service
See Notes: (6), (9) 31 - 50 add 1 add 1 add 1 add 1 people sink
51 - 75 add 1 add 1 add 1 add 1 per floor
76 - 100 add 1 add 1 add 1 add 1 (21)
ea. add'l 50 add 1 add 1 add 1 add 1
over 100

E-2: Elementary Grades 1 - 6 25 or less 1 1 1 1 1 per 1


26 - 50 add 1 add 1 add 1 add 1 100 service
See Notes: (6), (9) 51 - 75 add 1 add 1 add 1 add 1 people sink
76 - 100 add 1 add 1 add 1 add 1 per floor
ea. add'l 50 add 1 add 1 add 1 add 1 (21)
over 100

E-3: Secondary Grades 7 - 12 30 or less 1 1 1 1 1 per 1


and higher education facilities 31 - 60 add 1 add 1 add 1 add 1 100 service
61 - 100 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9), (17) ea. add'l 50 add 1 add 1 add 1 add 1 per floor
over 100 (21)
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 3

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Factory F-1 and F-2: Structures in which occupants are 25 or less 1 1 1 1 1 1 per 1
(F) engaged in work fabricating, assembling, or 26 - 50 add 1 add 1 add 1 add 1 emergency 250 service
processing products, materials, food, etc.. 51 - 100 add 1 add 1 add 1 add 1 shower per people sink
ea. add'l 100 add 1 add 1 add 1 add 1 10 people per floor
See Notes: (6), (9) over 100 exposed (21)
to skin
contamin-
ation.

Institutional I-1: Residential care, assisted living facilities (24-hour). 1 - 10 1 1 1 1 1 per 1 per 1
(I) ea. add'l 10 add 1 add 1 add 1 add 1 8 100 service sink
See Notes: (6), (9), (11) over 10 occupants occupants per floor
(21)

I-2: Patients in hospitals, nursing homes, etc. 1 water closet 1 lavatory 1 per
per per patient
patient room patient room room

I-2: Employees in hospitals, etc. 25 or less 1 1 1 1 1 per 1


26 - 50 1 1 0 0 100 service
See Notes: (6), (9) 51 - 100 add 1 add 1 add 1 add 1 people sink
ea. add'l 100 add 1 add 1 add 1 add 1 per floor
over 100 per wing

I-2: Visitors in hospitals, etc. 50 or less 1 1 1 1 1 per


51 - 100 add 1 add 1 add 1 add 1 500
See Notes: (6), (9) ea. add'l 100 add 1 add 1 add 1 add 1 people
over 100

I-3: Prisoners in prisons. 1 per 1 per 1 per 1 per


cell cell 15 100
prisoners prisoners

I-3: Detainees in reformatories, detention centers, and 15 or less 1 1 1 1 1 per 1 per


correctional centers. 16 - 30 add 1 add 1 add 1 add 1 15 100
31 - 50 add 1 add 1 add 1 add 1 detainees detainees
51 - 75 add 1 add 1 add 1 add 1
76 - 100 add 1 add 1 add 1 add 1
ea. add'l 50 add 1 add 1 add 1 add 1
over 100
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 4

Classification Occupany Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Institutional I-3: Employees in prisons, reformatories, etc. 25 or less 1 1 1 1 1 per 1
(I) 26 - 50 add 1 add 1 add 0 add 0 100 service sink
(continued) See Notes: (9) 51 - 100 add 1 add 1 add 1 add 1 people per floor
ea. add'l 50 add 1 add 1 add 1 add 1 per wing
over 100

I-3: Visitors in prisons, reformatories, etc. 50 or less 1 1 1 1 1 per


51 - 100 add 1 add 1 add 1 add 1 500
See Notes: (9) ea. add'l 100 add 1 add 1 add 1 add 1 people
over 100

I-4: Adult day care, child day care. 15 or less 1 1 1 1 1 per 1


16 - 30 add 1 add 1 add 1 add 1 100 service
See Notes: (9) 31 - 50 add 1 add 1 add 1 add 1 people sink
51 - 75 add 1 add 1 add 1 add 1 per floor
76 - 100 add 1 add 1 add 1 add 1 (21)
ea. add'l 50 add 1 add 1 add 1 add 1
over 100

Mercantile M: Stores, shops, markets, shopping centers, 50 or less 1 1 1 1 1 per 1


(M) sales rooms, service stations, etc. 51 - 150 add 1 add 1 add 0 add 0 500 service
151 - 400 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (7), (8), (9), (15) ea. add'l 400 add 1 add 1 add 1 add 1 per floor
over 400 (21)

Residential R-1: Hotels, motels, boarding houses (transient). 1 water closet 1 lavatory 1 1
(R) per per per service sink
guest room guest room guest room per floor
(21)

R-2: Dormatories, fraternities, sororities, 10 or less 2 2 2 2 1 per 1 per 1


boarding houses, (not transient). 11 - 20 add 1 add 1 add 1 add 1 8 people 100 service sink
ea. add'l 20 add 2 add 2 add 2 add 2 people per floor
over 20 (21)

R-2: Apartment houses, condominiums. 1 water closet 1 lavatory 1 1 kitchen


per unit per unit per unit sink per unit
See Notes: (10)
provisions for
1 clothes
washer per
20 units
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 5

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Residential R-2: One-and two-family dwellings. 1 water closet 1 lavatory 1 1 kitchen
(R) per unit per unit per unit sink per unit
(continued)
provisions for
1 clothes
washer
per unit

R-3: Congregate living facilities with 16 or fewer 10 or less 1 1 1 1 1 1 per 1


persons. ea. add'l 10 add 1 add 1 add 1 add 1 per 8 100 service sink
over 10 persons people per floor
See Notes: (9) (21)

R-4: Residential care, assisted living facilities. 10 or less 1 1 1 1 1 1 1


ea. add'l 10 add 1 add 1 add 1 add 1 per 8 per service sink
See Notes: (9) over 10 residents 100 per floor
people (21)

Storage S-1 & S-2: Structures for the storage of goods, 50 or less 1 1 1 1 1 per 1
(S) warehouses, storehouses, and freight depots. 51 - 100 1 1 0 0 500 service
ea. add'l 100 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (18), (19) over 100 per floor
(21)

Potrebbero piacerti anche