MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 1
Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-1: Theaters and other facilities for the viewing of 100 or less 2 2 1 1 1 per 1
(A) the performing arts or motion pictures, 101 - 200 add 1 add 1 add 1 add 1 500 service
typically with fixed seats. 201 - 300 add 1 add 2 add 0 add 1 people sink
ea. add'l 300 add 1 add 2 add 1 add 1 per floor
See Notes: (6), (9) over 300 (21)
Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-4: Coliseums, arenas, skating rinks, pools and 1 - 100 2 2 2 2 1 per 1
(A) tennis courts for indoor sporting events and 101 - 200 add 2 add 2 add 2 add 2 500 service
(continued) activities. 201 - 400 add 2 add 2 add 2 add 2 people sink
ea. add'l 400 add 2 add 4 add 1 add 2 per floor
See Notes: (6), (9), (20) up to 2600 (21)
ea. add'l 600 add 2 add 4 add 1 add 2
over 2600
Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Factory F-1 and F-2: Structures in which occupants are 25 or less 1 1 1 1 1 1 per 1
(F) engaged in work fabricating, assembling, or 26 - 50 add 1 add 1 add 1 add 1 emergency 250 service
processing products, materials, food, etc.. 51 - 100 add 1 add 1 add 1 add 1 shower per people sink
ea. add'l 100 add 1 add 1 add 1 add 1 10 people per floor
See Notes: (6), (9) over 100 exposed (21)
to skin
contamin-
ation.
Institutional I-1: Residential care, assisted living facilities (24-hour). 1 - 10 1 1 1 1 1 per 1 per 1
(I) ea. add'l 10 add 1 add 1 add 1 add 1 8 100 service sink
See Notes: (6), (9), (11) over 10 occupants occupants per floor
(21)
I-2: Patients in hospitals, nursing homes, etc. 1 water closet 1 lavatory 1 per
per per patient
patient room patient room room
Classification Occupany Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Institutional I-3: Employees in prisons, reformatories, etc. 25 or less 1 1 1 1 1 per 1
(I) 26 - 50 add 1 add 1 add 0 add 0 100 service sink
(continued) See Notes: (9) 51 - 100 add 1 add 1 add 1 add 1 people per floor
ea. add'l 50 add 1 add 1 add 1 add 1 per wing
over 100
Residential R-1: Hotels, motels, boarding houses (transient). 1 water closet 1 lavatory 1 1
(R) per per per service sink
guest room guest room guest room per floor
(21)
Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Residential R-2: One-and two-family dwellings. 1 water closet 1 lavatory 1 1 kitchen
(R) per unit per unit per unit sink per unit
(continued)
provisions for
1 clothes
washer
per unit
Storage S-1 & S-2: Structures for the storage of goods, 50 or less 1 1 1 1 1 per 1
(S) warehouses, storehouses, and freight depots. 51 - 100 1 1 0 0 500 service
ea. add'l 100 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (18), (19) over 100 per floor