Sei sulla pagina 1di 1

1 2 3 4 5 6 7 8

PROJECT
NOTE PARTITION SCHEDULE DRYWALL STEEL DOOR DRYWALL WINDOW
WALL DWG. A-06002 OPENING DETAIL OPENING DETAIL
A DOOR DESCRIPTION SPECIFICATION

H=22
H=2280mm

TYPE DETAIL
01. THIS SHOP DRAWING IS TO BE READ IN CONJUNCTION WITH DOORS,
WINDOWS, AND DRY WALL SYSTEM SUBMITTED SEPARATELY.
P.12 PARTITION TYPE
P.29 100mm SOLID BLOCK (310mm)
100mm SOLID BLOCK (320mm)
K10.127I 1I
WATERFRONT
P.39 K10.127R 2I
02. ALL DRY WALL ARE LAID UP TO SLAB SOFFIT UNLESS P.41 150mm HOLLOW BLOCK (210mm) K10.130A 4A INTEGRATED

H=2160 mm
H=2160 mm
SC3.02

OTHER WISE NOTED.


- H : HEIGHT P.42 150mm HOLLOW BLOCK (210mm) K10.130B 4B

HKN-SPD-AR-DW-10900 HKN-SPD-AR-DW-10902 HKN-SPD-AR-DW-10904


03. BLOCK WALL SETTING OUT SHOP DRAWINGS SUBMITTED
SEPARATELY.
- H2 : LOWER HEIGHT
P.43
P.44
150mm HOLLOW BLOCK (210mm)
150mm HOLLOW BLOCK
K10.130C
K10.130D
4C
4D
RESORT
A - CB : CEMENT BOARD P.45 150mm SOLID BLOCK (265mm) K10.130E 4E

H=2160 mm
H=2260
04. TYPICAL DRYWALL DETAIL : REFER TO

mm
H=2160 mm
H=2260

mm
H=2160 mm
H=2260
H=2160 mm
H=2260

HKN-SPD-AR-DW-031xx, 081xx & 09100 - FH : FIRE HOSE CABINET P.46 150mm SOLID BLOCK (295mm) K10.130F 4F
P.48 150mm SOLID BLOCK K10.130H 4H CLIENT
05. PLASTERBOARD LININGS FOR DRY AREAS NOT PART
SC1.02

FIRE RESISTANCE OF 30 MINUTES P.49 100mm HOLLOW BLOCK (270mm) K10.130I 4I


OF THIS SUBMISSION. 100mm SOLID BLOCK (315mm)
FIRE RESISTANCE OF 1 HOUR P.59 K10.131I 3I

H=2200 mm
P.62 150mm HOLLOW BLOCK (210mm) K10.131J 5B
FIRE RESISTANCE OF 2 HOURS
LEGEND P.64 150mm HOLLOW BLOCK K10.132A 5D
P.65 150mm SOLID BLOCK (260mm) K10.131K 5E
HOLLOW CONCRETE BLOCK WALL

ALIGNED

ALIGNED
P.66 150mm SOLID BLOCK (290mm) K10.131L 5F
HKN-SPD-AR-DW-10901 HKN-SPD-AR-DW-10903 HKN-SPD-AR-DW-10905 SOLID CONCRETE BLOCK WALL P.68 200mm HOLLOW BLOCK (335mm) K10.132C 5H John
P.69 100mm HOLLOW BLOCK (270mm) K10.132B 5I Keells
SC3.03 HOLLOW CONCRETE BLOCK WALL WITH PLASTER
NOT FOR CONSTRUCTION P.91 200mm SOLID BLOCK (300mm) K10.127S 8A Group
SOLID CONCRETE BLOCK WALL WITH PLASTER (SUBJECT TO CHANGE BY EMPLOYER ) P.94 200mm + 150mm SOLID BLOCK (600mm) K10.127V 8D
P.98 150mm SOLID BLOCK (513mm) K10.135D 8H
DRY WALL (DOUBLE FACED) ACCESS HATCH TO CEMENT BOARD / PLASTER
NOT FOR REVIEW A.H. K10.430C/K10.430D E-1F,2E-2F,3E-3F DESIGN CONSULTANT
BOARD PARTITONS
DRY WALL (SINGLE FACED)
CONCRETE STIFFNER

FOR CONTINUATION REFER TO DWG HKN-SPD-AR-DW-10900


B www.balmondstudio.com
A Registered in England & Wales No. 7225351

KEY PLAN
8000

F F
6
4 5
2

3 1
3.G

N
C
KEY ELEVATION
8000

REFERENCE NUMBERS STATUS

P.72
01 A-31121 E, A-31122 D
3.H TERRACE 02 HKN-RFI-AR-00988
UNDER
REVIEW
02
A 3.09 A
D 502 KIT
MALE TOILET
3.09 03

P.72

P.72

FOR CONTINUATION REFER TO DWG HKN-SPD-AR-DW-10904


P.71 CHANGING

P.72
B 505
02 CLEANERS ROOM FEMALE TOILET
3.09 3.09 3.09 04
P.71 P.24 009 508 509
P.72 P.22
05

P.22
EXTERNAL A P.22 A P.24
COVERED
SPACE
02 06
TERRACE STAIR S3.7

P.64
H=2160 mm H=2160 mm

H=2160 mm
3.09 07

H=2160 mm
P.71 A A P.22

P.62
503 3.09
8000

P.22

P.22
507

P.24
P.24 08
P.22

P.22 09
P.72
P.69
P.69

PLANT ROOM CORRIDOR


STORAGE 3.09 FFL = +31.00
3.09 P.75

P.22
024 013 SSL =+30.90

H=2160 mm
H=2160 mm
3.09

P.75

P.75
506 A
A A A

E
3.J

H=2160 mm
BAR B

3.09
F&B FSL3.05 FSL3.06
019
(SHELL & CORE)
3.09 Service/ Service/
551
Fire Fighting Fire Fighting
Lift Lift

A 11.02.2019 FOR CONSTRUCTION

A1 04.01.2019 FOR APPROVAL


H=2160 mm
8000

A ISSUE
PLANT ROOM SC3.03 REV. DATE
3.09

H=2160 mm
A 3.09
014
022 ISSUE STATUS
FFL = +31.00
SSL =+30.90
H=2160 mm 3.09
FOR CONSTRUCTION
A 020

FFL = +31.00 3.09


SSL =+30.90 015 DRAWING TITLE
F PLANT ROOM

3.K BUILDING 1 & 3


LEVEL 09 - 2/6
DRY WALL SETTING OUT PLAN

SCALE 1:100 DATE 11.02.2019


F&B DRAWN BY HM
(SHELL & CORE)
8000

3.09
566
CHECKED BY BRUNO / STC

DRAWING NO. REVISION


RETAIL SHELL &
CORE ENTRANCE
3.09
HKN-SPD-AR-DW-10901 A
501
G

SUB CONTRACTOR

3.L

MAIN CONTRACTOR
4700

HYUNDAI
ENGINEERING & CONSTRUCTION CO. LTD.
75, YULGOK-RO, JONGNO-GU, SEOUL, KOREA
WWW.HDEC.CO.KR

3.M
TERRACE TERRACE
H
530-17 Dapsimni 5-dong, Dongdaemoongu, Seoul, Korea
www.kne.co.kr

NAWALOKA CONSTRUCTION
3600 8000 8000 8000 8000 8000 8000 8000 8000 CO. (PVT) LTD
NO: 115, SIR JAMES PEIRIS MAWATHA,COLOMBO 02, SRILANKA.
WEB : www.nawaloka.lk

3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9

Potrebbero piacerti anche