Problem Description
While trying to run an AV-transformation mapping (or PowerCenter Mapplet), the following error is reported:
Cause
1. Incorrect information in the Address Validation properties field of the Content Management System.
No Pre-Load Countries, Partial Pre-Load Countries AND Full Pre-load Countries are left empty.
It is advised to have at least No Pre-Load Countries set to ALL.
2. The used version of libAddressDoctor.so (or libAddressDoctor.dll) are older than the version officially released with this version of
(Example: Using version 5.2.9 with Informatica 9.5.1 HotFix 3 (with 5.4.0)
Solution
1. Set all No Pre-Load Countries = ALL in the Address Validation properties of the CMS properties window.
2. Update libAddressDoctor.so (or libAddressDoctor.dll) at least to the official released version of Informatica 9.
Restart the Content Management Service and Data Integration Services after making changes to the CMS properties to have them a
More Information
After editing the AD50.cfg file, a restart of the PowerCenter Repository Services or PowerCenter Integration Services is not necessar
Operating System.
The -1101 error refers to the internal AddressDoctor Library error message "An XML string is invalid".
https://kb.informatica.com/solution/23/Pages/4/155497.aspx 1/2