Sei sulla pagina 1di 36

Hexing MDC System

Protect Your Revenue

Hexing Confidential 保密
Contents
• System Overview
• Key Technologies
• Main Application
What problems can MDC system solve?

 Remote meter reading (AMR)


 Remote meter programming
 Extended metering - Water metering、Gas metering
 Sub-metering
 Tampering management & Event notification
 Provides metering data for line loss analysis
 Load profile & load control
 Remote tariff programming-including Step , TOU…
 Data collect for transformer monitoring device

w w w.hxgroup.cn Page 3
We provide a integrated MDC system

w w w.hxgroup.cn Page 4
System Architecture
AM PEMS
CIM SCADA
( CIM based ) ( CIM based )

CIM Adapter CIM Adapter

Enterprise Service Bus ( CIM based )

MDM MDC Transformer


( CIM based ) ( CIM based ) Monitoring System

WAN
1) Installation with GPS
2) Meter reading
3) Field Maintenance

DC :
1) Meter reading HHU
2) Transformer Monitoring

PLC/RF Gas
CT / PT
HV meter
meter

Water
3 phase meter 1 phase meter

w w w.hxgroup.cn Page 5
Key Features

Integrated system

Whole scope load balance

Well design HEAD-END platform

Enhanced supports for operation maintenance

w w w.hxgroup.cn Page 6
Key Features
Integrated System
1. Managed object including (1)HV gate meter, (2)smart circuit
breaker, (3) (~10kv)HV meter, (4) LV meters, (5) network products, (6)
LCU …

2. Core applications:
 Metering data collection
 Asset management
 Power quality monitoring
 Transformer monitoring
 Load management
 Tampering management (Line loss analysis and control)
 Smart pay ( AMI + Prepayment)
 VEE ( core component of MDM)
 Interface service

w w w.hxgroup.cn Page 7
Key Features
Whole scope load balance
 HEAD-END, DB, Web Application, all support cluster
 Support huge scale of meters
 Support high concurrency with high performance

Well design HEAD-END platform


 Advanced HEAD-END architecture design
 Rich protocols supported: DLMS, ANSI, DCSML,
DNP3, IEC60870-5-101, IEC60870-5-104…
 Modular driver model for meter & DC

w w w.hxgroup.cn Page 8
Key Features
Enhanced supports for operation maintenance
 Device auto discovery & registration
 Supervision of communication flow;
 Supervision of data collection quality;
 Supervision state of system components.

w w w.hxgroup.cn Page 9
Contents
• System Overview
• Key Technologies
• Main Application
Physical Architecture
Background Process:
Web Server 1) batch operation task
-MDC config 2) Missing rereading
Database

Protocols
Communication
Processor
Scheduler

Gate

Firewall

w w w.hxgroup.cn Page 11
System Integration

ERP/ MDM Billing


Via ESB
AM
1) Install meter Billing data
2) Replace meter export

MDM-MDC integration points:


1) Install / replace meter
2) Meter reading
3) Events reading
4) Load control

CIM based Enterprise Business Bus


( SOA,IEC61968,61970,61850 )

Database CIM based


MDC
Interface

w w w.hxgroup.cn Page 12
Independent HEAD-END Technology

APN / VPN

Firewall

s
y
n
c

w w w.hxgroup.cn Page 13
Installation Technology
Auto-discovery

Engineer 1
PLC / RF
DC

ERP Install Form

Event

Engineer 2

First msg

Detect
meter type

Auto-config AMI
Power on

Automatic Install & debug

w w w.hxgroup.cn Page 14
Auto-Periodic Meter Reading

Interval & activate configurable

Data item is configurable


Template
(Auto) Apply

3 2 1 0 Meter-Read-Time is dispersed

Asynchronous, high concurrency

Auto-Reread when network failed

w w w.hxgroup.cn Page 15
Monitoring of Whole System

 Daemon for each Gate of HEAD-END;


Event notified to administrators
 Real time monitoring for Components: Gate,
Scheduler, BP, DB, Web Application,
Interface Service
 Operation report send to administrator at
7:00 AM

w w w.hxgroup.cn Page 16
Remote Communication Technology

 GPRS/CDMA, internal module, external module


 SMS
 CSD
 GPRS/CDMA, On-demand on-line (Period-on + SMS wake up)
 Optical fiber
 Ethernet ( external module )

w w w.hxgroup.cn Page 17
Network Plan for Residential
GPRS Meters
Applicable Scenario GPRS
Ethernet
 Residents widely dispersed, PLC
signal is not good
 VIP residents, example : 3 phrase
consumers Transformer Meter

 AMI network performance is highly Smart Meter

required.

Smart Meter

w w w.hxgroup.cn Page 18
Network Plan for Residential
DC + PLC + Meters
Applicable Scenario GPRS
Ethernet
 Power grid suitable for PLC;
 Residential district;
 Rural house.

Transformer Meter DC

Technical Parameters Smart Meter

 Nodes supported by DC:1024 ;


 Max distance:3000 m ;
 Average response time between DC
& meter:15 seconds .
Smart Meter

w w w.hxgroup.cn Page 19
Network Plan for Residential
DC + RFmesh + Meter
GPRS
Ethernet

Transformer Meter DC

Smart Meter

Applicable Scenario
 Power grid is complex, not suitable
for PLC.
 Example: Old district.

w w w.hxgroup.cn Page 20
Network Plan for Residential
Collector + 485 + Meters
GPRS
Ethernet

Transformer Meter DC

Smart Meter

Applicable Scenario
 Power grid is complex
 Harmonic disturbance
 Wire-less signal attenuation Smart Meter

 Meter installation is central


 Example: district, shopping mall….

w w w.hxgroup.cn Page 21
Network Plan for Residential
DC + RFmesh Collector + 485
GPRS
Ethernet

Transformer Meter DC

Smart Meter

Applicable Scenario
 Power grid is complex
Smart Meter
 Meter installation is central
 high-rise residential building
 shopping mall

w w w.hxgroup.cn Page 22
Cost Comparison for GPRS Communication

GPRS PLC RF 485 RF+485

Meters 1 500 500 64 500

Install Cost x 500x 700x 128x 800x

Install Cost Each Meter x x 1.4x 2x 1.6x

Communication Cost y 2y 2y 1.5y 2y

Communication Cost Each y 0.004y 0.004y 0.023y 0.004y

w w w.hxgroup.cn Page 23
Security Mechanism Firewall
Anti-virus
Security of passwords

 RBAC
 Data access control
 IP/MAC restrictions
Master Station  Traceability

 AES-GCM
 Soft or hardware ciphering
 Meters connect to certain IP

Operators

User

w w w.hxgroup.cn Page 24
Contents
• System Overview
• Key Technologies
• Main Application
Application

Load Control

Transformer Monitoring Supporting

GIS

Operation & Maintenance

w w w.hxgroup.cn Page 26
Meter Reading for Line Loss Analysis
110KV / 35KV

110KV

F1 F2

Feeder
Line

AMI
Meter

Transformer 10KV / 220V HV Switch


Meter

C&I

AMI Meter
Master Meter Secondary Meter
C&I
w w w.hxgroup.cn Page 27
Alarm/Event Management
 GPRS meter or DC event notification
 Events reading & Management
 Events Analysis & Handling – ( Anti-tampering )

w w w.hxgroup.cn Page 28
Load Control
Device
AMI Meter

• For residents:Internal relay


• C&I: Internal relay control External circuit
breaker

Smart-pay Meter

• Similar to AMI meter. Provides prepayment


functions.

LCU

• LCU - Managed by concentrator through PLC

C&I Metering Cabinet

CIU or IHD

w w w.hxgroup.cn Page 29
Load Control
Master Station

Remote
connect/disconnect Load control Real time load
-single or parameters profile to display
download, meter load control
multiple or by activate result
group

w w w.hxgroup.cn Page 30
Load Profile & Load Control
 Load profile programming using template
 Load curve data for region, transformer area, or single measure-point
 Direct load control
 Parameterized load control – by load or circuit limit

w w w.hxgroup.cn Page 31
Events Reading for Outage Analysis
 Outage information collection – by Events
 Outage reports, by month or year
 Provides power supply reliability indicator
 Supports indicators :SAIFI、CAIFI、CAIDI、SAIDI

w w w.hxgroup.cn Page 32
Transformer Monitoring Support
• Voltage, Current
Operating States • Active, Reactive load
Real-time • Energy indicator
Monitoring • Oil temperature, Oil level
• Branch status

Reliable
Operating • Over load
Security • Three phase unbalance
Evaluation • Phase missing

Economical

Economical • Line loss analysis


Analysis • Reactive compensation
Safety

Power Quality • Voltage qualification rate


Analysis • Harmonic analysis

w w w.hxgroup.cn Page 33
GIS

w w w.hxgroup.cn Page 34
System Operation Supervision

Daily Week Month Year


analysis bulletin score appraisal

Install Operation Maintenance Application


• Installation • Data Integrality • Alarm Handling • Metering Data
Coverage Rate • Communication Rate Application Rate
success-rate

w w w.hxgroup.cn Page 35
www.hxgroup.cn
Add: 1418Moganshan Road, Shangcheng Industrial
Zone, 310011, Hangzhou City, China

Tel : +86-571-28020767/769
Fax : +86-571-28029263
Email: market@hxgroup.co

w w w.hxgroup.cn

Potrebbero piacerti anche