Single-port synchronous controller T-1000


A .T-
-1000 system features
1ǃ32ü256 Gay, Gamma correction procession software
2ǃSupport points, lights, and surfaces light source, rules and specific-shaped handle
3ǃSingle-port output, can support 1024/2048 light
4ǃOff-line control, playback content stored in the SD card
5ǃInput 220V AC power to achieve the same power, AC synchronous; split screen, the overall
synchronization.
6ǃT-1000 store a maximum of 16 documentsˈcan copy multiple documents to the SD card
in orderˈfile number are˖00.led, 01.led, 02.led, 03.ledĂ
NOTE˖T-1000 port 512 lights, the playback speed of up to 30 frames / sec, the port more than 512
lights, the frame rate with the increase in the number of lights automatically reduced.

Support chips˖
Support chips LedEdit Single one Remarks
corresponding support lights
model
LPD6803,D705,1101, T-1000-6803 2048pixels
6909,6912
LPD8806,LPD8809 T-1000-8806 2048pixels
TM1803,TM1804,T T-1000-TM 2048pixels TM1804andT
M1809,TM1812 M1809are
devided into
high and low
speed
DMX512 T-1000-DMX 170/512pixels Compatible
standard
DMX512agree
ment
WS2801,WS2803 T-1000-WS 2048pixels
TLS3001,TLS3002 T-1000-TLS 2048pixels
P9813 T-1000-P9813 2048pixels
SM16715 T-1000-SM16715 2048pixels
SM16716 T-1000-SM16716 2048pixels
BS0815 T-1000-0815 2048pixels
Match 6909,6912 T-1000-HL32 Must connect
1024pixels ™
Guardrail tube sub-control
board
sub--control

quantity

-1-
Rohopa Industry Limited
www.rohopa.com Tel: 86-755-23013296 E-mail: teresa@rohopa.com

B .Appearance˖

the output terminals definition˖


Project Meaning
AC IN 220V AC input
Red line
᧤clock᧥
CLK᧤ ᧥
White line
᧤signal᧥
DAT᧤ ᧥
Black line
᧤ground᧥
GND᧤ ᧥

˖
DIP switch˖4ü1˄File˅

ಧ1)
(4ಧ
0000 00.led
0001 01.led
0010 02.led
0011 03.led

-2-
Rohopa Industry Limited
www.rohopa.com Tel: 86-755-23013296 E-mail: teresa@rohopa.com

0100 04.led
0101 05.led
0110 06.led
0111 07.led
1000 08.led
1001 09.led
1010 10.led
1011 11.led
1100 12.led
1101 13.led
1110 14.led
1111 15.led
NOTE˖In the form, DIP statusþ0ÿmeans OFFˈþ1ÿmeans ON
DIP switch˖8ü5˄Speed˅˖
(8ü5)
0000 25frames/S
0001 16frames/S
0010 12frames/S
0011 10frames/S
0100 8frames/S
0101 7frames/S
0110 6frames/S
0111 5frames/S
1000 4frames/S
1001 3frames/S
1010 2frames/S
1011 1.5frames/S
1100 1frames/S
1101 0.6frames/S
1110 0.5frames/S
1111 0.4frames/S
NOTE˖In the form, DIP statusþ0ÿmeans OFFˈþ1ÿmeans ON
Other projects definition˖
Power Power LED
Status Running status indicator
SD Card SD card slot

C .Wiring diagram˖

-3-
Rohopa Industry Limited
www.rohopa.com Tel: 86-755-23013296 E-mail: teresa@rohopa.com

NOTE˖1.Playback stored in the SD card


2.220 V AC, and power, AC synchronous
3.The PC software automatically split screen, multiple controllers can play a whole picture

D. Specific parameters˖
Memory Card:
Type˖SD Card
Capacity˖256MBü2GB
File Format˖FAT file format
Store files˖*.led

Physical parameters˖
Temperature˖-40ćü85ć
Power Supply˖220V AC
Power˖5W

NOTE˖
1ǃTo copy files to SD card ˈyou must first format the SD card, pay attention to is
that each copy must be formatted before.
2ǃSD card must be formatted as "FAT" formatDŽ

-4-
Rohopa Industry Limited
www.rohopa.com Tel: 86-755-23013296 E-mail: teresa@rohopa.com

The SD card in controller can not be hot-swappable, plug the SD card every time, you must
first disconnect the power supply

E. Common problems exclude˖


Q1˖After powerˈthe T-1000 AC ERROR indicator STATUS has been flashing without display output
ANSWER˖The ERROR indicator STATUS has been flashing means the controller did not read the
card correctly, possible problems:
ķSD card is empty, with no effect file
ĸThe effect file in the SD card and the controller model are not match, please choose
correct controller model in LedEdit and then re-create the effect file *led
ĹSD card did not format to FAT before copy effect files
ĺChanging the SD card and then test to exclude the possibility of a bad SD card
Q2: The controller is powered on, the indicator is normal, but no effect change in lighting
ANAWER: The reasons for this are as follows:
ķ Check if the lightingĄs signal line and the controller connected correctly
ĸ If the TTL signal is received, the lamp and the controller must be common ground,
that means connect the lightingĄs and the controllerĄs ground together
Ĺ Check if the model chose during making display files on the SD card match the chips
used in the lighting