Calculation Checklist

Customer #REF! Proj No #REF!


Project Title #REF! Calc No #REF!
Calculation Title #REF! Phase/CTR #REF!
Elec File Location
#REF!
Project File Location #REF! Page 2 of #REF!
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
✘ Calculation number assigned and registered (refer to project numbering system or Document Numbering System
EPP-0040 for format).
✘ Project title shown.
✘ Calculation title shown.
✘ Revision history box complete and signed.
✘ Index.
✘ Appropriate stamp for preliminary issues.
✘ Calculation objectives (aims) stated.
✘ Calculation method defined or described (including formulae if relevant).
✘ Reference made to text, standard or code. Check version/edition with that required for project.
✘ Source of input data stated (with revision number and date if relevant).
✘ Assumptions stated.
✘ Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available. (Not applicable)
✘ Approach used is appropriate for problem being solved.
✘ Method clear and easy to follow.
✘ Input data correct.
✘ Calculation arithmetically correct OR software previously verified and reference to verification checked.
✘ Calculation result within expected limits.
Calculation tolerances stated if significant. (Not applicable)
✘ Units used as required by client.
✘ Abbreviations correct.
✘ Appropriate cross-references.
✘ Sketches included and clearly labeled, where required.
✘ Appendices included and referenced, as required.
✘ Considered design reviews, HAZOP actions, client input, safety and environmental issues, etc. (in later stages)
Checking Records:
Checked and annotated copy of calculation filed (use "Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.

#REF! #REF! #REF! #REF! #REF! #REF!


#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
0.00 #REF! #REF! #REF! #REF! #REF!
Rev Date Description By Checked Approved

002-000-PDF-566 (015311) EPF-0027


Corporate Base Page 1 of 5
Rev 2 (5-Mar-07)
Calculation Sheet

Customer #REF! Proj No #REF!


Project Title #REF! Calc No #REF!
Calculation Title #REF! Phase/CTR #REF!
Elec File Location #REF!
Project File Location #REF! Page 4 of 5
Rev Date By Checked Rev Date By Checked Rev Date By Checked Rev Date By Checked

#REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF!
FOR ETHYLENE LOADING LINE (INSULATED WITH POLYURETHANE FOAM (PUF))

Basis: Unit length of pipe


PIPE SIZE Notes:
PIPESIZE Symbol Unit 0.5" 0.75" 1" 1.5" 2" 3" 4" 6" 8" 10" 12" 1 To account for Solar
Pipe Schedule 40S 40S 10S 10S 10S 10S 10S 10S 10S 10S 10S Radiation, Ts is taken as
PIPE OD D1 mm 21.336 26.67 33.401 48.26 60.325 88.9 114.3 168.275 219.075 273.05 323.85 50 oC
PIPE ID D0 mm 15.7988 20.9296 27.8638 42.7228 54.7878 82.804 108.204 161.468 211.557 264.668 314.706
Wall thickness Xp mm 2.7686 2.8702 3.3782 3.683 3.9116 3.048 3.048 3.4036 3.7592 4.191 4.572 2. To meet design heat
Thermal Conductivity (SS304L) Kp W/m.K 13.74 13.74 13.74 13.74 13.74 13.74 13.74 13.74 13.74 13.74 13.74 flux of 25 W/m2, insulation
INSULATION thickness needs to be
Material PUF PUF PUF PUF PUF PUF PUF PUF PUF PUF PUF increased to 100 mm from
Thickness Xi mm 75 75 75 100 100 100 100 130 130 130 130 1.5" to 4" and to 130 mm
Thermal Conductivity (PUF) Ki W/m.K 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 from 6" to 12".
OD of insulation D2 mm 171.34 176.67 183.40 248.26 260.33 288.90 314.30 428.28 479.08 533.05 583.85
HEAT INGRESS CALCULATION
Ambient design temp Tamb ºC 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0
Bulk ethylene fluid temp. To ºC -103.0 -103.0 -103.0 -103.0 -103.0 -103.0 -103.0 -103.0 -103.0 -103.0 -103.0
Surface Temp Ts ºC 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0
Temp difference ΔT ºC 153.0 153.0 153.0 153.0 153.0 153.0 153.0 153.0 153.0 153.0 153.0
Convective heat transf coeff (air) ha W/m².K 8 8 8 8 8 8 8 8 8 8 8
Conductivity of insulation Ki/Xi W/m².K 0.3333 0.3333 0.3333 0.2500 0.2500 0.2500 0.2500 0.1923 0.1923 0.1923 0.1923
Conductivity of pipeline Kp/Xp W/m².K 4963 4787 4067 3731 3513 4508 4508 4037 3655 3278 3005
Convective heat transf coeff (fluid) hi W/m².K 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
Resistance due to air conv 0.23 0.23 0.22 0.16 0.15 0.14 0.13 0.09 0.08 0.07 0.07
Resistance due to ins cond 13.26 12.04 10.84 10.43 9.31 7.50 6.44 5.95 4.98 4.26 3.75
Resistance due to pipe cond 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Resistance due to fluid conv 1.01 0.76 0.57 0.37 0.29 0.19 0.15 0.10 0.08 0.06 0.05
Total resistance due to heat 14.27 12.80 11.42 10.80 9.60 7.70 6.59 6.05 5.06 4.32 3.80
Heat flux q W/m² 19.91 21.54 23.26 18.16 19.49 21.90 23.52 18.81 20.10 21.15 21.93
Overall heat transfer coeff U W/m².K 0.242 0.254 0.264 0.152 0.156 0.158 0.156 0.091 0.087 0.083 0.078
External surface area As m² 0.538 0.555 0.576 0.780 0.818 0.908 0.987 1.345 1.505 1.675 1.834
Q value based on overall Us W/m 19.91 21.54 23.26 18.16 19.49 21.90 23.52 18.81 20.10 21.15 21.93

002-000-PDF-566 (015311) EPF-0027


Corporate Base Page 2 of 5
Rev 2 (5-Mar-07)
Theoretical Background
Tamb,4 , h4
Tbulk,1 , h1

Tbulk,1 , h1

Tamb,4 , h4
Tbulk,1

Tamb,4

Tbulk,1 Tamb,4

Heat transfer rate is expressed as: temperature driving force

T bulk, 1−T amb, 4


qr=
1 ln( r 1 / r 2 ) ln ( r 3 / r 2 ) ln( r 4 / r 3 ) 1
+ + + +
2 πr 1 Lh1 2 πk A L 2 πk B L 2 πk C L 2 πr 4 Lh4

internal convection term heat conduction terms external convection term

Nomenclature:
qr heat transfer rate through the pipe (in W) h convective heat transfer coefficient (in W/m².K)
r radius (in mm) T temperature (in °C)
k thermal conductivity (in W/m.K)
L length of pipe

002-000-PDF-566 (015311) EPF-0027


Corporate Base Page 3 of 5
Rev 2 (5-Mar-07)
INSTRUCTIONS:

1 Yellow boxes indicate input data is required. Calculation results will not be displayed correctly if
data or incorrect data is filled into these boxes.

2 Blue boxes indicate calculation outputs. There are 2 forms of output arising from the calculation,
depending on the type of calculation performed.
[1] Determination of insulation thickness. The maximum heat influx allowed must be set as a constraint
to determine the thickness of insulation needed.
[2] Heat flux into the pipe given an insulation thickness. The amount of heat flux per unit length of
pipe can be determined.

3 *Save* this worksheet often. This cannot be emphasized more than enough.

4 Input data must be keyed into the boxes are listed below. Appropriate references are given below.
**CAUTION** - Please use values of ambient conditions with care and seek professional help if in doubt.

REFERENCES:

Air properties can be obtained from

[1] Sloanne, B.A. (1992) 'Maximise your energy savings with proper insulation size'
Hydrocarbon Processing. October.

[2] Bront, B. (1995) 'Spreadsheets for heat loss rates and temperatures'.
Chemical Engineering. December.

Further reading:

[1] Incropera. (2002) 'Fundamentals of Heat and Mass transfer' 5th Ed.

[2] Welty, Wicks, Wilson, Rorrer. (2003) 'Fundamentals of Momentum, Heat and Mass Transfer'
4th Ed.

002-000-PDF-566 (015311) EPF-0027


Corporate Base Page 4 of 5
Rev 2 (5-Mar-07)
Calculation Sheet

Customer #REF! Proj No #REF!


Project Title #REF! Calc No #REF!
Calculation Title #REF! Phase/CTR #REF!
Elec File Location
#REF!
Project File Location 0 Page of #REF!
Rev Date By Checked Rev Date By Checked Rev Date By Checked

0 ### 0 0 0 ### 0 0 0 ### 0 0

Calculation of convective heat transfer coefficient for pipe fluid

Fluid Name Ambient Temperature 0 °C


Fluid Type

For turbulent flow in smooth pipes, the Dittus-Boelter equation holds:


NuD = 0.023× Re0.8 Prn
where n = 0.4 for heating (Ts > Tm) and n = 0.3 for cooling (Ts < Tm)

Fluid Properties Input


Property Symbol Data Input Units Useful conversions
Density ρ kg/m³ 1 kg/m³ = 1000 g/cm³ = 0.062428 lb/ft³
Heat Capacity k W/m.K 1 W/m.K = 0.577789 Btu/ft.h.°F
Dynamic Viscosity μ Pa.s 1 Pa.s = 1000 cP
Volumetric Flowrate F m³/s
Temperature T °C 1°C = 33.8°F

Pipe Properties Input


Property Symbol Data Input Units Useful conversions
Pipe ID Do mm 1 inch = 25.4 mm

Calculation Results
Variable Symbol Data Output Remarks
Flow velocity V m/s
Reynolds Number Re For fluid flow in pipe, if Re > 2000, flow is turbulent.
Prandtl Number Pr
n value
Flow regime in pipe Laminar Dittus-Boelter correlation cannot be used, use Nu = 3.66

Nusselt number Nu
Heat transf coeff hi W/m².K

002-000-PDF-566 (015311) EPF-0027


Corporate Base Page 5 of 5
Rev 4 (27-Aug-08)