S.NO. DESCRIPTION D.S.R AMOUNT D.S.R + 120% N.S.R + 10% Total D.S.R Value Total N.S.R Value
AMOUNT
I CIVIL WORKS
AMOUNT
S.NO NAME OF SUB-HEAD
DSR 2016 NON-DSR
I EARTH WORK
II CONCRETE WORK
IV BRICK WORK
V MARBLE WORK
VI WOOD WORK
VIII FLOORING
IX ROOFING
X FINISHING
XI WATER PROOFING
I EARTH WORK
1 Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in
depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead upto 50m and lift upto
1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil Cu.M
2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains
(not exceeding 1.5m in width or 10 Sq.M on plan) including dressing of sides and ramming ob bottoms, lift upto 1.5m,
including getting out the excavated soil and disposal of surplus excavated soil as directed, withen a lead of 50m.
II CONCRETE WORK
5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All
work upto plinth level.
1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu.M
6 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters,
columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets,coping, bed blocks,
anchor blocks, plain window sills, fillets, etc. upto floor five level, excluding the cost of centring, shuttering and finishing:
1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cu.M
1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Cu.M
7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate Sq.M
20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and
grouted with fine sand including finishing the top smooth
8 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,
shuttering, finishing and reinforcement - All wirk upto plinth level:
1:1½ :3 (1cement :1½ Coarse sand: 3 graded stone aggregate 20 mm nominal size) Cu.M
9 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string
courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of
centering, shuttering, finishing and reinforcement.
1:1½:3 (1 cement :1½ Coarse sand : 3 graded stone aggregate 20 mm nominal size) Cu.M
Reinforced Cement concrete work in beams, suspended floors, roofs having slope upto 15 0 landings, balconies, Cu.M
shelves, chajjas, lintels, bands, plain cases upto floor five level excluding the cost of centering, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement : 1.5 Coarse sand : 3 graded stone aggregate 20mm nominal size) in lieu of
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Rate for RCC 1: 1.5 :3
Rate of item No. 5.3 for RCC 1:2:4 ( Cement 3.20 Qtl/Cu.M) = 3673.85
Code 0367 - Add Extra cement for 1:1 1/2:3 (0.80@450.00 Qtl) = 360.00
3673.85+360 = 4033.85
Difference of Cement = 4.00-3.20=0.80 Qtl
10 Centring and shuttering including strutting, propping etc. and removal of form for:
Suspended floors, roofs, landding, beams and balconies (plan area to be measured.) Sq.M
12 Providing hoisting and fixing upto floor five level precast reinforced cement concrete in mouldings as in cornices, Cu.M
windows sills etc. including setting in cement mortar 1 : 3(1cement ;3 coarse sand) cost of requird centring, shuttering
and finishing smooth with 6mm thick cement plaster 1 : 3(1cement : 3 fine sand) on exposed surfaces complete but
excluding the cost of reinforcement with 1:2 :4 (1cement : 2coarse sand : 4 graded stone aggregate 20mm nominal
size)
13 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
upto plinth level.
IV BRICK WORK
16 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
Cement mortar 1:6 (1 cement: 6 coarse sand) Cu.M
17 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes
and sizes in:
Cement mortar 1:6 (1 cement: 6 coarse sand) Cu.M
18 Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level
V MARBLE WORK
20 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen
platforms, vanity counters, windows sills, facias and similar locations of required size of approved shade, colour and
texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement,
mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high
gloss finish etc. complete at all levels.
Raj Nagar Plain white marble / udaipur green marble / Zebra black marble
Area of slab over 0.50 sqm Sq.M.
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
21 Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width up 150 mm R.M.
with epoxy resin based adhesive including cleaning etc. complete
22 Extra for providing opening of required size & shape for wash basins / kitchen sink in kitchen platform, vanity counters Each
and similar location in marble / Granite / stone work including necessary holes for pillar taps etc. including rubbing and
polishing of cut edges etc. complete.
VI WOOD WORK
23 Providing wood work in frames of doors, windows, clearestory windows and other frames, wrought framed and fixed in
position:
18 mm thick Sq.M.
25 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block
board construction with frame of 1st class hard wood and well matched commercial 3 ply venerring with vertical grains
or cross bands and face veneers on both faces of shutters:
35 mm thick without using ISI marked Stainless Steel butt hinges. Sq.M.
Rate = 929.95-112.60=817.35
25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sq.M.
26 Providing and fixing 30mm thick wire gauge shutters using galvanised M.S. wire gauge of average width of aperture
1.4mm with wire of dia. 0.63 mm for doors, windows and clerestory windows including ISI marked Stainless Steel butt
hinges with necessary screws:
Kiln seasoned and chemically treated Hollock wood Sq.M
27 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws
including drilling hole in masonry work /CC/ R.C.C. and making good etc. complete.
50 mm long Each
28 Providing and fixing wooden moulded beading to door and windows frames with iron screws, plugs and priming coat on
unexposed surface etc. complete.
Hollock wood
50x12mm R.M.
29 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.
all complete.
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
300x16 mm Each
250x16 mm Each
33 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:
1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
250x10 mm Each
100x10 mm Each
34 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade with necessary screws etc.complete:
125 mm Each
100 mm Each
75 mm Each
35 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC
10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
40 Suppling and fixing rolling shuters of approved make, made of required size M.S laths interlocked together through
their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,
side guides and arrangement for inside and outside locking with push and pull operation complete including the cost of
providing and fixing necessary 27.5 cm long wire springs grade No. 2 and M.S top cover pf required thickness for
rolling shutters.
80 x 1.25 mm M.S laths with 1.25 mm thick top cover Sq.M.
41 Providing and fixing ball bearing for rolling shutters Each
42 Extra for providing mechanical device chain and crank operation for operating rolling shutters
43 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S bar instead of laths as per design Sq.M.
approved by Engineer in charge.(area of grill to be measured.)
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
44 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and Kg
welded with 15x3mm lugs 10 cm long embedded in cement concreete block 15x10x10cm of 1:3:6 (1 cement: 3 coarse
sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or
with dash fastener or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and
screws and applying a priming coat of approved steel primer.
45 Providing and fixing pressed steel door frames confirming to IS:4351 manufactured from commercial mild steel sheet of
1.25mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section
50x25 mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means,
adjustable lugs with split end tail to each jamb including steel butt hings 2.5 mm thick with mortar guards, lock strike-
plate and shock absorbers as specified and aplying a coat of approved stel primer after pre treatment of the surface as
directed by Enginer-in-charges:
Profile B R.M.
Profile C R.M.
Steel work welded in built up sections/ framed work including cutting hoisting, fixing in position and applying a priming
coat of approved steel primer using structural steel etc. primer using structural steel etc. as required
In stringers, treads, landings etc. of stair case including use of chequered plat where ever required, all complete Kg
In gratings, frames, guard bar ladder, railings, brackets, gates and similar works Kg
46 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase
railing including applying a priming coat of approved steel primer.
M.S. tube. Kg
G.I. pipes Kg
VIII FLOORING
47 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed
with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 m thick bed of cement
mortar 1:4 (1 cement: 4 coarse sand)
Medium shade with 50% white cement and 50% ordinary cement. Sq.M
48 Marble stone flooring wilth 18 mm thick marble stone (sample of marble shall be approved by Engineer-in charge) over
20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed wth grey cement slurry
including rubbing and polishing complete with:
Raj nagar plain Sq.M
49 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with
pigment to match the shade of the slab including rubbing and polishing complete with base of 1:4 (1 cement :4 coarse
sand):
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
25 mm thick Sq.M
50 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar Sq.M
1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match te shade of the slabs,
including rubbing and polishing complete.
51 Extra for pre finished nosing in treads of steps of kota stone / sand stone slab R.M.
52 Extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. Sq.M
53 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the Sq.M
manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by
Engineer-in-charge in skirting. risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with
pigment of matching shade complete.
54 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st Sq.M
quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey Fume Red Brown, laid on 20
mm thick Cement Mortar 1:4 (1 Cement: 4 Coarse sand) including pointing the joints with white cement and matching
pigment etc., complete.
IX ROOFING
56 Providing gola 75x75mm in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10mm and down
gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design:
In 75x75mm deep chase R.M
57 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : Each
4 graded stone aggregate of 20 mm nominal size) over P.V.C sheet 1mx1mx400micron, finished with 12mm cement
plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the
outlet complete.
58 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including
joints with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes
X FINISHING
59 15 mm cement plaster on the rough side of single or half brick wall of mix:
1:6 (1 cement: 6 fine sand) Sq.M
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
68 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint Sq.M
applied @ 2.20kg/10 sqm).
69 Applying priming coat:
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel Sq.M
works
70 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
Two or more coats on new work Sq.M
71 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and Sq.M
manufacture.
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
72 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia Each
steel bar conforming to IS: 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm
and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard
drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having
manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15
cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete
as per design.
73 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
L D - 2.5
Rectangular shape 600x450mm internal dimensions Each
74 Providing and laying integral cement based water proofing treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc conisting of following operations: a) Applyaing a slurry coat of neat cement
using 2.75 kg/sq. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-
in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before
treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement
mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by
Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water
proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly
the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with
water proofing compound conforming to IS: 2645 and approve by Engineer-in-charge. d) Finishing the surface with 20
mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound
conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth aproved quality in top
layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm
square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for
curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-
Charge:
With average thickness of 120mm and minimum thickness at khurra as 65 mm. Sq.M
S DSR ESTIMATE AMOUNT (in
DESCRIPTION UNIT RATE (in Rs.)
No 2016 Code No. QUANTITY Rs.)
3 Providing applying cementitious crystalline based water proofing for concrete rafts, walls, water tanks, slabs, concrete Sq.M
floors etc with krystol T1 system. The application to be done from +ve(postive) side on wet open pore concrete surface
with brush @ 1Kg/Sq.M as per manufacturer specification.
SUMMARY OF COST INTERNAL PLUMBING WORKS
AMOUNT
S.NO NAME OF SUB-HEAD
DSR 2016 NON-DSR
IV SEWERAGE SYSTEM
TOTAL
2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat
and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever),
conforming to IS : 7231, Parryware/Hindware/Seabrid /Orient (Coral) with all fittings and fixtures
complete including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked black solid plastic seat and lid each
4 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white
PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions
and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other
couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors
wherever required:
Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern. each
5 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and
1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and
embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse
sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished
smooth.
a Granite Stone of approved shade sqm
6 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and
stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls
wherever required :
Kitchen sink with drain board
510x1040mm bowl depth 250mm each
S. ESTIMATE RATE (in Amount
DSR 2016 Code No. DESCRIPTION UNIT
NO QUANTITY Rs.) (in Rs.)
7 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
8 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete each
with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers
complete.
CP Brass fittings
9 Providing and fixing toilet paper holder
CP brass each
10 Providing and fixing unplasticised PVC connection pipe with brass unions
45 cm length
15 mm nominal bore each
11 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
150 mm diameter each
12 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
a) 15 mm nominal bore each
13 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and
weighing not less than 690 gms.
a) 15 mm nominal bore each
14 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality
conforming to IS:8931
a) 15 mm nominal bore each
2 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick,
bolts and nuts complete.
100 mm
Sand cast iron S&S as per IS-3989 each
4 Providing and fixing single equal plain invert branch of required degree:
100x100x100mm
Sand cast iron S&S as per IS-3989 each
5 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without
vent arm complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS-3989 each
6 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of
diameter:
100 mm each
7 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good
the walls etc. (internal work)
Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good
the wall (for Waste Conn.from WB/Urinals/Sinks)
a 32 mm dia nomina bore metre
(226.10+4.55+36.65)
b 40 mm dia nominal bore metre
(264.05+5.20+36.65)
8 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) 75mm in bed and around C.I Soil and waste pipe (embedded in the flooring /
ground)
a 100 mm dia metre
1 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized &
ant - microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R
plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing.
This includes testing of joints complete as per direction of Engineer in charge.
2 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized &
anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R
plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing.
This includes the cost of cutting chases and making good the same including testing of joints complete
as per direction of Engineer in charge.
Concealed work ,including cutting chases and making good the walls etc.,
a PN - 16 Pipe, 16 mm OD metre
b PN - 16 Pipe, 20 mm OD metre
c PN - 16 Pipe, 25 mm OD metre
d PN - 16 Pipe, 32 mm OD metre
3 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end )
a 25 mm nominal bore each
b 32 mm nominal bore. each
c 40 mm nominal bore. each
IV SEWERAGE SYSTEM
1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the
proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete
150 mm diameter metre
2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40
mm nominal size) alround S.W. pipes including bed concrete as per standard design:
3 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry
chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be
not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.
NON-SCHEDULED ITEMS
2 Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with Each
mounting bracket fixed on wall complete.[FOR EWC]
3 Providing & fixing 4 mm thick SS hinged grating with rim of approved design including setting in floor
with cement mortar.
125 mm dia Each
80 mm dia Each
4 Providing and fixing CP brass copper inlet connection of size 15mm nominal bore 45cm length with Each
brass unions.
5 Providing & Fixing CP brass liquid soap container fixed to the wall with PVC rubber plug with C.P brass Each
screw complete each
6 Supplying & Fixing of CP soap tray fixed to the wall with PVC rubber plug with CP brass screws. Each
7 Suppying and fixing Towel rail of size 600x20mm complete with bracket fixed to wooden cleats with CP Each
brass screws.
S. ESTIMATE RATE (in Amount
DSR 2016 Code No. DESCRIPTION UNIT
NO QUANTITY Rs.) (in Rs.)
8 Providing and fixing hinged stainless steel construction anti-cockroach trap with grating including fixing
to the floor trap complete in all respects.
a). 100mm dia Each
9 Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of Each
approved quality conforming to IS:8931. 15 mm nominal bore
10 Providing and Fixing, testing and commissioning of vertical / horizontal storage type hot water heater
fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non return valve complete
including making connection with 15 mm dia CP connecting pipe on Inlet and Outlet, suitable length of
power cable and 15A plugh.
Capacity 15 liters Each
1 Providing and fixing cast brass clean out plug with suitable insert keys for opening in brass cap, male
threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe /Floor trap including cost of
lead joints etc. complete in all respect.
100 mm dia. Each
2 Providing and fixing G.I Inlet fitting with maximum 3 inlets 32, 40 or 50 mm size fabricated from 100 mm
dia G.I pipes(approx. length=150mm to 300mm) and welded G.I sockets, fixed to CI trap with lead
caulked joint and set in cement concrete as per standard drawing including cost of Bitumastic paint
complete. Each
3 Providing and fixing floor drain with 65mm x 50mm GI Elbow with cement mortar, compelete in all
respect Each
2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end )
20mm nominal bore each
S. ESTIMATE RATE (in Amount
DSR 2016 Code No. DESCRIPTION UNIT
NO QUANTITY Rs.) (in Rs.)
SUMMARY OF INTERNAL ELECTRICAL WORKS
AMOUNT
S.NO NAME OF SUB-HEAD
DSR 2016 NON DSR
I POINT WIRING
IV EARTHING SYSTEM
I POINT WIRING
Group C Points
Supplying and fixing following size / modules, GI box along with modular base & cover plate for
modular switches in recess etc as required
1 or 2 Module (75 mm x 75 mm) Each
4 Module (125 mm x 75 mm) Each
40 Amps Each
IV EARTHING SYSTEM :
MV Cable laying upto 120 sqmm. In same trench: Laying of one number PVC insulated and PVC
sheated /XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 120
sqmm direct in ground including excavation, sand cushioning, protective covering and refilling
26 the trench etc. as required. Mtrs
Note : Manhole is not considered in Electrical Estimation it will come on Civil Estimation.
Supplying, fixing, connecting & testing of Telephone Tag Block krone type in a suitable size
1.6 mm thick dust and vermin proof Sheet steel enclosure duly painted by synthetic enamel over
anti corrosive primer, lockable and hinged cover with provision for cable through glands complete
in all respects.
33
10 pair krone Each
50 pair krone Each
Supplying, laying, testing and commissioning of following size anealed tinned copper conductor
PVC insulated and sheathed armoured copper telephone cables with suitable clamps, saddles
and including making terminal joints complete as required.
34
10 pair Mtrs
50 pair Mtrs
S DSR ESTIMATE RATE (in Amount
DESCRIPTION UNIT
No (Reprint-2010) QUANTITY Rs.) (in Rs.)
Supply and Erecting modular type computer jack RJ 45 ISI mark approved make with mounting Each
35 plate and box with wiring connections complete.
Supplying & installing UTP networking Cat-6 cable suitable for LAN/WAN computer net working
36 as per catalog no. DC6CAUTP4P3X. Mtrs
Supply, installation, testing and commissioning of CAT 6 giga speed patch cord 2m or equivalent Each
37 feet and factory terminal at both ends as per catalog no. DC6PCURJO2GYM.
Supply and installation of 24 port CAT 6 patch panel modular type complete as required as per Each
38 catalog no. DC6PP24UKY1U.
Supply, installation, testing and commissioning of CAT 6 giga speed patch cord 1.2m or Each
39 equivalent feet and factory terminal at both ends as per catalog no.DC6PCURJ01GYM.
Supply, installation, testing and commissioning of wall mounted data rack 12 U with glass door Each
40 hardware, cable manager, cooling fans power points etc.
Supply, laying and end terminations including connections of 6 core outside plant cable
corrugated steel tape armoured, loose tube, gel filled 50/125 micron OM cube fiber multi mode
armoured fibre optical cable in wall/floor/ground complete as required in one segment with fiber
41 connector as per catalog no. DFCA051GSTO6. Mtrs
42 Supply, installation, testing and commissioning of 12 Port 10/100 Edge Switch. Each
43 Supply, installation, testing and commissioning of GE SFP, LC connector LX/LH transceiver. Each
Supplying, laying, testing & commissioning of following sizes of 1.1 KV XLPE insulated
Aluminium conductor armoured cables in existing hume pipe or laid in existing trenches or laid
and tied on existing overhead cable trays; complete as required and as per specifications
44 complete as required and as per specifications.
Supply of surface mounting 1 x 36 watt T8 Lamp,with ballast, low loss magnetic gear (PF>.9)
45 with lamp complete in all respects. Each
Supply of surface mounting 1x18 watt CFL satin finish diffuser , low loss magnetic gear, IP23.
46 with lamp complete in all respects. Each
Supply of wall mounting 1x18 watt CFL satin finish diffuser , low loss magnetic gear, IP23. with
47 lamp complete in all respects. Each
Supply of surface/wall mounting 1 x 18 watt mirror light T8 Lamp, low loss magnetic gear with
48 lamp complete in all respects. Each
Supply of Industrial Bulk head fitting of cast aluminium body having heat resistant glass cover
and M.S galvanised wire guard suitable for and with 9/10 watt CFL complete in all respects.
49 Each
Supply of surface mounting 1x36W, G13 ATEX Category 2 certified flameproof Eex d linear
50 fluorescent luminaire, complete in all respects. Each
51 Supply of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. Each
Supplying of Exhaust Fan Heavy duty 230V A.C 50 cycles 375 mm 1400 RPM complete erected
52 in position with all accessories. Each
S DSR ESTIMATE RATE (in Amount
DESCRIPTION UNIT
No (Reprint-2010) QUANTITY Rs.) (in Rs.)
TOTAL(XII)
SUMMARY OF COST EXTERNALELECTRICAL WORKS
AMOUNT
S.NO NAME OF SUB-HEAD
DSR 2016 NON DSR
II EARTHING SYSTEM
V EXTERNAL LIGHTING
VI TRANSFORMER
X FIRE EXTINGUISHER
Supplying and making end terminations with brass compression glands and aluminium lugs for following
1 size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
MV Cable laying upto 400 sqmm. on surface: Laying of one number PVC insulated and PVC sheated
2 /XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm on surface Metre
as required.
MV Cable laying upto 400 sqmm. In same trench: Laying of one number PVC insulated and PVC
sheated /XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm
3 direct in ground in the same trench in one tier horizental formation including excavation, sand cushioning Metre
protective covering and refilling the trench etc as required.
MV Cable laying upto 25 sqmm. In same trench: Laying of one number PVC insulated and PVC
4 sheated /XLPE power cable of 1.1 KV grade of size not exceeding 25 sqmm direct in ground including Metre
excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supply, laying, jointing, testing and commissioning of ISI marked (IS : 14930, part 2) H.D.P.E. (DWC)
Double wall Corrugated pipe for cable laying having corrugation on outer wall and plain smooth surface
at inner side including transportation upto the site, jointing, providing and fixing all fittings i.e. sockets,
12 couplers, reducers, end caps etc to complete the works in all respects.
50 mm. ID / 65 mm OD Mtrs.
Supplying and laying of following sizes of RCC hume pipes NP2 grade in road crossings and below
paved areas laid and jointed complete with collars as required including excavation, road cutting and
making good the damages etc including Cement concrete in foundations filling and mass concrete.1:4:8
13 (1cement 4 coarse sand and 8 grit 40 mm and below.( below Hume pipes)
100 mm. dia Mtrs.
Design, manufacturing, testing at works, supply, installation, testing and commissioning of floor mounting
free standing totally enclosed indoor cubical extensible compartmentalized front operational vertical dust
and vermin proof D.G Isolator Panel fabricated out of 2 mm thick CRCA sheet steel provided with hinged
detachable lockable and front and back openable comparmentalised individual chamber doors including
strengthening and stiffening complete as requiredand as per specifications. The panel shall be powder
coated after proper treatment with 8 tank process and shall be provided with following components :-
14 Nos.
INCOMER :
125A FP Disconnecting switch with over load and SSC Protection - 1 Nos.
Phase Indicating Light (R,Y,B) - 3 Sets.
Design, manufacturing, testing at works, supply and delivery of floor mounting free standing totally
enclosed indoor cubical extensible compartmentalized front operational vertical dust and vermin proof
main LT panel fabricated out of 2 mm thick CRCA sheet steel provided with hinged detachable lockable
and front and back openable comparmentalised individual chamber doors including strengthening and
stiffening complete as requiredand as per specifications. The panel shall be powder coated after proper
treatment with 8 tank process and shall be provided with following components :-
(Note : The fault withstanding capacity shall be 20 KA for one sec. Earth bus shall be part of the panel).
One No. 125A, 20KA, Four pole MCCB suitable for cable connection on incoming side and busbar
connection on outgoing side. (63 KVA Transformer incomer) The MCCB shall be electrically and
mechanically interlocked with bus coupler/DG incomer. The MCCB shall be complete with all the in built
protections as required.The breakers shall be provided with microprocessor based release/relay having
variable range of overcurrent, short circuit and earth fault protection with time lag facility for each of the
fault for achieving discrimination.
b Bus Bars :
200Amps, 20 KA, TPN Aluminium Bus Bars of suitable length. Bus bars shall be colour coded and
insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be
1.2 sq.mm./amp.
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
c Outgoings :
All outgoing feeders shall be provided with R,Y,B Phase indicating lamps with 2A SP MCB, Digital
Ammeter with CT's.and Ammeter Selector Switch.
2 Nos. 80 amp FP MCCB of 20 KA breaking capacity.
2 Nos. 100 amp FP MCCB of 20 KA breaking capacity.
2 Nos. 63 amp FP MCCB of 20 KA breaking capacity.
1 Nos. 63 amp TP MCCB of 20 KA breaking capacity.
Main L.T. Panel / DG Panel described as above and all as per specification.
Design, manufacturing, testing at works, supply of 20 KVAR capacitor bank panel consisting of 4 Nos. 5
KVAR capacitor units (3 W + 1 S.B) in tier formation; housed in an integrated cubicle type, indoor type
automatic switching 'ON' and 'OFF' control panel with dust and vermin proof hinged and lockable doors
complete with interconnections, bonding to earth and painting (suitable for 400/440 Volts, 3 phase 50 Hz
supply system).
Automatic switching "ON" and "OFF" with 4 steps automatic control relay on the control panel for 30
KVAR capacitor banks. Each panel consists of: -
e Incoming :
1 No. 63 amp TP MCCB of 20 KA breaking capacity. (This shall be part of Main L.T panel), and already
included in L.T. panel.
Indicating Panel (Capacitor Bank)
Phase indicating lamps each backed up with 2 amp fuses and ON/OFF toggle switches.
Indicating lamp in each capacitor chamber unit to indicate "ON"/"OFF" status of capacitor unit.
Stepped relay with 4 steps (4 Nos.5 KVAR (1W+1S.B).
f Outgoings :
Note :- The Capacitor panel shall be integrated alongwith the L.T panel as shown in the
schematic diagram.
Design, manufacture, testing at works, supply of medium voltage (415 V) SDB cubicle type as per
technical specification and comprising of the following (Refer schematic diagram). All MCCB to be of
motor duty.
(Note : The panels shall be a FRONT operated, with cable entry from the top. Earth bus shall be part of
the panel.)
Incoming :
Indicating Panel :
The Indicating panel of the incomer shall be provided with the following :
One (1) No. (0-500V) 96 x 96 Sq.mm voltmeter and voltage selector switch
One (1) No. (0-80A) 96 x 96 Sq.mm CT operated Ammeter & Ammeter selector switch.
3 Nos. phase indicating lamps; backed up with 2 A MCB.
Bus Bar :
1 No. 200 amp TPN Alumanium Bus bar of suitable length with current density of 1.2 sq.mm/amp .
Outgoing :
Incoming:
1 No. 100 amp FP MCCB of minimum 20 KA breaking capacity.
Metering:
The Indicating panel of the incomer shall be provided with the following :
One (1) No. (0-500V) 96 x 96 Sq.mm voltmeter and voltage selector switch
One (1) No. (0-100A) 96 x 96 Sq.mm CT operated Ammeter & Ammeter selector switch.
3 Nos. phase indicating lamps; backed up with 2 A MCB.
Bus Bar:
200A, TPN aluminium bus bar of suitable length with colour coded sleeves.
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
Outgoings:
2 Nos. 63 A FP MCB of 10 KA breaking capacity.
2 Nos. 40 A FP MCB, 10 KA breaking capacity.
6 Nos. 40 A DP MCB, 10 KA breaking capacity.
3 Nos. 20 A DP MCB, 10 KA breaking capacity. Nos.
Incoming:
1 No.63 A FP MCB (10KA)
1. No.60 A Power Contactor with Daily Dial Timer 24 hour, 230 V A.C
Metering:
One (1) Set of Phase Indication Lamp with 2A SP MCB.
Bus Bar:
200A, TPN aluminium bus bar of suitable length with colour coded sleeves.
Outgoing:
7 Nos. 25A FP MCB (10 KA). Nos.
Supplying, installation, testing and commissioning of 2x11 watt CFL(Double nos. luminare) with PV
module 120 watt, Battery capacity 12 V, 100AH, Solar street light system with mounting structure and 6 m
pole. Note : Foundation work for Post top Pole is not involve in
20 Electrical works it will come on Civil work Nos.
Supplying and fixing of sodium vapour lamp street lighting luminaries single piece cast aluminium body
suitable for 2x70 Watt H.P.S.V lamp including integral control gear 2x70 watt H.P.S.V lamp on G.I Pipe
bracket complete in all respects including 6 m Steel Tubular swaged pole with suitable size of Junction
box and connectors, G.I Pipe for cable inlet and outlet . Note : Foundation
work for Street Light Pole is not involve in Electrical works it will come on Civil works.
21 Nos.
Supplying and fixing of sodium vapour lamp street lighting luminaries single piece cast aluminium body
suitable for 70 Watt H.P.S.V lamp including integral control gear 70 watt H.P.S.V lamp on G.I Pipe bracket
complete in all respects including 6 m Steel Tubular swaged pole with suitable size of Junction box and
connectors, G.I Pipe for cable inlet and outlet . Note : Foundation work
for Street Light Pole is not involve in Electrical works it will come on Civil work.
22 Nos.
Grand Total
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
(VI) TRANSFORMER :
Design, manufacture,testing at works, supply and delivery of the 63 KVA outdoor type transformer (oil
filled) as specified, in the Technical specifications, complete with the following standard, mountings,
23 fittings, accessories, etc as required. Nos.
l) Radiator with top and bottom shut off brass gate valves.
m) Rating and Diagram plate.
n) Bi-directional Plain/Flanged Rollers as required.
o) Drain cum bottom filter valve - 1 no.
p) Explosion vent with double diaphragm and sight glass.
q) 100 mm dial magnetic oil level gauge with max pointer and low level alarm contacts.
r) 150 mm dial oil temperature indicator (OTI) with max pointer and 2 sets of Contacts for Alarm & trip.
s) 150 mm dial winding temperature indicator (WTI) with max pointer & 2 sets of contacts for alarm & trip.
(Winding temperature indicators individually for each phase)
t) Magnetic oil level indicator with annunciation.(1 Working + 1 Standby)
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
u) Marshalling box with GLS lamp point and 15A switchsocket oulet point with watertight lockable cover at
the top.
v) De - Hydrating Breather.
w) Two Earthing Terminals.
Note : Foundation work for Transformer is not included in Electrical works it will come on Civil
work.
Grand Total
24 H.T. PANEL (11KV SINGLE PANEL BOARD NEAR ENTERENCE & NEAR GUARD ROOM) : Nos.
Design, manufacturing, testing at works, supply, installation, testing and commissioning of HT Panel as
per specification and comprising of the following:-
INCOMING PANEL :
630 A Vacuum circuit breaker of (350 MVA) 18.42 KA ruputuring capacity at 11 KV rated, totally
enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked
horizontal drawout type having double isolation features and control devices complete with the following:
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck
mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF
indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip
(shrouded) test/service position limit switches with 6 NO/6NC breaker auxilliary contacts in service
position,30/24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
630 amp air insulated but encapsulated,PVC insulated Copper bus bars.
C.T. chamber with double wound, C.T.'s 50/5 (seperate core for metering and separate core for protection).
a) All wiring necessary for the above including inter-connections. The size of the conductor should not be
less than 2.5 sq. mm. Copper wire where required.
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
b) Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standard
practise as under.
c) Red - Breaker close (ON)
d) Green - Breaker open (OFF)
e) Amber - auto trip
f) Clear - trip circuit healthy
g) white - 3 nos. one per phase
h) Blue spring charged
i) The following meters are to be provided :
j) Frequency meter, digital and vibrating reed type 47 to 55 range for panel cutout of 13 reeds in a row.
k) Digital Voltmeter range 0-15 KV, and suitable for 110V AC 144 x 144mm square dial with shrouded
terminal & protection fuses,with Voltmeter Selector Switch.
l) Digital Ammeter, with Ammeter Selector Switch
m) Power factor meter - Range - 0.5 lag to 0.5 lead.
n) Trivector meter with MDI.(Electronic)
o) DC Volt meter, 0-30 Volt, Digital type.
p) 6-window annunciation panel with audio and visual indicator.
q) Over current & earth fault - 2 windows
r) Spare - 4 windows
s) Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm.
t) Control :- T-N-C (Trip, Neutral. Close) breaker control switch with indication arrangement.
u) Terminal boxes with single gland trifucating cable box suitable (Raychem make) for 11 KV Aluminium
XLPE (E) cable of size 3 x 150 Sq. mm. for incoming breaker.
v) HT Danger Plate.(as per IS specification)
w) 2 Runs of 32 X 6 mm earth bus shall be provided for the full length of the panel.
Earth switch as required
HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above
in A and B items and as per specifications.
DSR ESTIMATE RATE (in Amount
S.No. DESCRIPTION UNIT QUANTITY Rs.) (in Rs.)
2016 Code No.
Supply, laying, testing and commissioning of 11KV(E), XLPE armoured, shielded & PVC sheathed cable
25 with aluminium conductors.
In ground including excavation, sand cushioning, protected with subclass ’B’ brick covering and refilling
the trench & disposal of surplus soil.
3 core 150 sqmm Mtrs.
Termination of the following sizes of XLPE insulated conductor armoured cable including providing
terminal lugs,single compression glands crimping the joints,providing insulation tape, effecting terminal
26 connections to the equipment complete as required.
3 core 150 sqmm Nos.
Supplying, laying, testing & commissioning of following sizes of 1.1 KV XLPE insulated Aluminium
conductor armoured cables in existing hume pipe or laid in existing trenches or laid and tied on existing
overhead cable trays; complete as required and as per specifications complete as required and as per
specifications.
27
Supplying and Laying of 25 mm X 5 mm Copper strip at 0.50 metre below ground as strip earth electrode,
28 including soldering etc. as required. Mtrs
Providing and Fixing Portable Fire Extinguisher Co2 Type with cylinder initially fully charged with Co2 gas
of 4.5 kg capacity. Complete with discharge valve discharge tube horn CI bracket for wall mounting etc.
29 conforming to IS 2878. Nos.
DSR ESTIMATE RATE (in Amount