∂h ∂p
Energy L ( h) ≡ ρ + ρ u ⋅ ∇h − ∇ ⋅ ( ρ D∇h ) =− ρ w F Q +
∂t ∂t
T T
Sensible
=h ∑Y ∫
i
i c pi ( T=
′ ) dT ′ ∑
=
i
Yh ∫ i i c p ( T ′ ) dT ′
Tref Tref
enthalpy
c p ∇=
T ∇ h − ∑ hi ∇ Yi
definition i
Coupling functions
Super-Scalar Formulation
Consider Leff / ( 1-YFs(Ts ) ) to be uniform over gas-liquid
interfaces. Then, a super scalar S can be constructed
which is uniform over the gas (but possibly time-varying).
is normalized by
2500 2500
T T
(TS-298)/(TWB-298)=0.4
(TS-298)/(TWB-298)=0.2
YF 0.8 YF 0.8
YO YO
2000 2000
TS=TWB
0.6 0.6
(TS-298)/(TWB-298)=0.2
(TS-298)/(TWB-298)=0.4
YF , YO
YF , YO
1500 1500
T
T
0.4 0.4
TS=TWB
1000 1000
0.2 0.2
500 500
0 0
0 0.25 0.5 0.75 1 0 0.25 0.5 0.75 1
Φ Φ
Ambient pressure
0.6
Ambient temperature
ΦF
Flames become 0.4
Decane, Air
approximately spherical Decane, O2
Heptane, Air
at large distances from 0.2 Heptane, O2
the droplet array Methanol, Air
Methanol, O2
1
Conduction-
limit d / a0 = 6: Conduction-limit
d / a0 = 6 d / a0 = 6: Infinite conductivity
d / a0 = 10
Infinite 100
0.8 conductivity d / a0 = 10: Conduction-limit
No heating d / a0 = 10: Infinite conductivity
d / a0 = 6 80
d / a0 = 50 d / a0 = 50: Conduction-limit
0.6
( a / a 0 )2
No heating
d / a0 = 50 d / a0 = 50: Infinite conductivity
ql
__
.
60
0.4
40
0.2
20
0 0
0 0.5 1 1.5 0 0.25 0.5 0.75 1
t / tiso t / tiso
The gas-phase for any geometry is governed by
0.6 0.6
0.5
ηΑ
0.5
ηΑ
0.4 0.4
Curve-fit
Curve-fit
0.3 9-drop 0.3
9-drop
27-drop
0.2 0.2 27-drop
64-drop
30-drop
0.1 125-drop 0.1 64-drop
0
0 2 4 6 8 10 12 0
ξ 0 2
ξ 4 6
The spherical
mesh is updated
as the droplet
surface regresses;
ρ∞U '∞ ,0 d 0
initial Reynolds number Re0 =
µ∞
d 0 / U '∞ ,0
initial Damkohler number Da0 =
ρ∞YFo /(ω ο M F )
o
where F and ω ο are the reference mass fraction
Y
for the fuel vapor and reference reaction rate.
Benchmarking of Code
A single isolated droplet was analyzed first using an axisymmetric
code with a spherical mesh. The hybrid spherical / Cartesian
3D mesh was checked against these results.
YF
YO
For lower initial Reynolds number (Re) and/ or higher initial Damkohler
number (Da), flame is initially an envelope flame and remains so for lifetime.
For higher initial
Reynolds number
and /or lower initial
Damkohler number,
flame is initially a
wake flame but
transitions later to
an envelope flame as
droplet slows.
Both droplet size and
relative velocity
decrease with time.
The deviation from
classical R2 law
increases as Re
becomes larger.
Droplet velocity decrease has a greater effect on residence time increase than
droplet size decrease has on residence time decrease. So, residence time
increases with time, allowing transition to envelope flame.
All of these qualitative features found in the single-droplet results
persist for the transient vaporization and burning of arrays.
Burning rate increases with initial
Re. For higher Re cases, transition to
envelope flame occurs, causing a
sudden increase in burning rate and
liquid surface temperature.
Vaporization rate increases with Da;
so, the flame is not thin and not
completely diffusion-controlled.
Flame shapes for different sp0 or Re0
Re0 = 9 ( Da0 = 1.5), sp0 = 5.9d 0 Re= 45 ( Da= 0.3), sp= 5.9d 0
0 0 0
Re0 =
9 ( Da0 =
1.5) Re0 =
45 ( Da0 =
0.3)
• The instant of wake-to-envelope transition advances first and
then is delayed as the initial droplet spacing decreases, because of
the gas velocity behavior between the adjacent droplets.
• The burning rate is influenced by the interactions amongst
droplets and the instant of wake-to-envelope transition.
Periodic Arrays with Two Layers
Droplets in Tandem
Staggered Droplets
Reo=110
Flame Structure for Periodic Array
with Two Staggered Layers
Transverse Spacing= 3.8 do
s/Ro = 5.6
Reo = 45
Front Droplet
Aft Droplets
Concluding remarks (1)
In the transient process for a droplet array, an initial envelope
flame remains an envelope flame, and an initial wake flame has a
tendency to develop from a wake flame to an envelope flame.
Similarly to isolated droplets, the flame standoff distance does
not vary significantly the during the lifetime.
Generally, if a flame is initially a separated, individual flame for
each droplet ( or a group flame for many droplets), it remains a
separated flame (or group flame) for a long time.
For an initial wake flame, the wake-to-envelope transition time
advances as the initial droplet spacing (intermediate) is
decreased, but then delays as the initial droplet spacing is
further reduced.
The critical initial Damkohler number for the determination of
an initial envelope or wake flame does not vary with initial
Reynolds number and decreases with decreasing initial droplet
spacing for intermediate spacing values, but has no substantial
change when the initial droplet spacing becomes too small.
Concluding remarks (2)
Burning rate is influenced by the Reynolds number, wake-to-
envelope transition time, and interaction amongst droplets.
Smaller initial droplet spacing or initial Reynolds number may
yield greater burning rate (for some period during the lifetime)