Sei sulla pagina 1di 4

Learning Home Catalog Transcript

Home ► Final Test - Broadband Premises Troubleshooting Part 1* ► ►


Final Test: Broadband Premises Troubleshooting Part 1*

Started on Saturday, February 3, 2018, 11:22 AM


State Finished
Completed on Saturday, February 3, 2018, 12:18 PM
Time taken 56 mins 14 secs
Grade 83.33 out of a maximum of 100.00
Feedback Congratulations on successfully completing the Broadband Premises Troubleshooting
Part 1 Final Test!

Question 1 Most issues and interference that may be encountered from MoCA service can be found in
Correct the:

Marked out of 1.00


Select one:
Flag question
a. Headend

b. Transport System
c. Premises

d. Node

e. Outside the home

Question 2 Existing home splitters and amplifiers that are not MoCA compatible will block MoCA
Correct signals.

Marked out of 1.00


Select one:
Flag question
True

False

Question 3 The customer tells you that the television was purchased in 2009, so there should be no
Correct problem with 3D format.
Marked out of 1.00 Select one:
Flag question True

False

Question 4 Which is TRUE about leakage detection equipment that is used by an installer?
Correct
Select one:
Marked out of 1.00
a. ensure there are signals leaking after completing a service call or installation
Flag question
b. improve RF signal power by detecting leaking twisted pair cabling
c. it is better to measure leakage at multiple frequencies to ensure leakage is within
specifications throughout the cable spectrum
d. for precise signal level leakage measurements use a flexible whip antenna

Question 5 Which statement below is correct about a telephone circuit?


Correct
Select one:
Marked out of 1.00
a. Tip is represented by a white/blue or red conductor and has a negative voltage.
Flag question
b. Tip is represented by a white/blue or green conductor and has a positive voltage.
c. Ring is represented by a white/blue or red conductor and has a positive voltage.
d. Tip is represented by a blue/white or green conductor and has a negative voltage.

Question 6 What is the average ratio of average signal constellation power to average constellation
Correct error power, expressed in decibels called?

Marked out of 1.00


Select one:
Flag question
a. bit error ratio
b. signal to noise

c. codeword error rate


d. modulation error ratio

e. forward error correction

Question 7 Place the troubleshooting steps in the correct order.


Correct
Step 1
Marked out of 1.00

Flag question Analyze


Step 2

Isolate

Step 3

Divide and Conquer

Step 4

Resolve

Step 5

Confirm

Question 8 True or False: The channel plan allows the meter to look at the correct parameters on each
Correct individual channel so that it can accurately read the signals coming off the HFC network.

Marked out of 1.00


Select one:
Flag question
True
False

Question 9 When using a multimeter to test a length of coax cable, a reading of zero was received.
Incorrect Which statement below best describes this situation?

Marked out of 1.00


Select one:
Flag question
a. A reading of zero indicates a potential short between the center conductor and
shielding.
b. A reading around zero indicates that the cable is working properly across its length.

c. A reading of zero resistance indicates an open somewhere along the the inside of
the cable.
d. A reading around zero indicates a ground fault that occured by a fault connector.

Question 10 Match the usable IP addresses in the typical IPv4 static IP packages offered by cable
Correct operators.

Marked out of 1.00


/28
Flag question
13
/29

/30

Next ►

QUIZ NAVIGATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

39 40 41 42 43 44 45 46 47 48

Show all questions on one page

Finish review

Powered by Coursestage from Web Courseworks Ltd.


Copyright ©2018 Society of Cable Telecommunications Engineers, Inc. All rights reserved.

Potrebbero piacerti anche