Sei sulla pagina 1di 16

BILL NO.

5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Premix Road

A Excavate for premix road 660mm deep to reduce


level commencing at platform level, get out and
remove surplus excavated material from site 700 M2

B Sub-grade road formation level to gradient and


crossfall and rolled as specified 700 M2

C 100mm sub-base (compacted thickness) unwashed


sand, spread, levelled in two layers and rolled with
10 ton roller 700 M2

D 450mm (consolidated thickness) of crusher run,


spread and levelled in two layers and rolled with 10
ton roller 700 M2

E Prepare and apply bitumen tack coat at the rate of


1.80 litre per square metre 700 M2

F 50mm (consolidated thickness) layer of premix


binder course, spread, levelled and rolled to falls
and chamber with 6 ton roller 700 M2

G 60mm (finished) layer of premix wearing course,


spread, levelled and rolled to falls and chamber with
6 ton roller 700 M2

Road Kerb

H 550mm x 350mm high slipform concrete grade 25


extruded kerb (Type SM-1) with top splayed,
straight or curve finished fall, 100mm thick concrete
mix grade 15 base, bedded and jointed in cement
mortar (1:3) and including excavation, painting,
formwork, intersection, angle mould, forming outlet,
joisting, haunching and other necessary work all
conforming to Local Authority's requirement and
Engineer's detail 812 M

J Extra over forming dropper/crossing kerb to


Engineer's detail 30 M

BQ/5/1 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Driveway Concrete Slab

A Excavate for concrete driveway 500mm deep to


reduce level commencing at platform level, get out
and remove surplus excavated material from site
1,960 M2

B 70mm sub-base (compacted thickness) unwashed


sand, spread, levelled in two layers and rolled with
10 ton roller 1,960 M2

C 305mm (consolidated thickness) of crusher run,


spread and levelled in two layers and rolled with 10
ton roller 1,960 M2

D 125mm thick concrete Grade 30 slab 1,960 M2

E Fabricated reinforcement BRC no. A7 1,960 M2

F Extra over forming 25mm x 25mm thick groove line


on ramp surface 245 M2

Concrete Imprint

G Supply and lay 100mm thick concrete imprint with


approved pattern including concrete, formwork,
reinforcement and other necessary works all in
accordance with manufacturer's specification 2,569 M2

Entrance Slab

H Reinforced concrete entrance slab approximate


3000mm width x 213mm thick complete with Y10
reinforcement as main bar, Y16 as trimmer bar,
BRC A7 laid on top and bottom, 100mm thick well
compacted sand, 450mm thick crusher run, 2 no.
610mm x 450mm heavy duty mild steel grating
(measured separately), 2 nos. wing wall 150mm x
300mm high complete with plastering and including
excavation, formwork and other necessary work all
as per Engineer's detail drawing 13 M

BQ/5/2 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Walkway

A To construct 100mm thick cast-in-situ concrete bed


complete with one layer fabricated wire mesh BRC
no. A7, 50mm thick sand bedding and 100mm x
250mm high restrain including excavation,
formwork, forming steel grating opening and other
necessary works all to Engineer's approval 551 M2

B Supply and lay approved 300mm x 300mm Tack tile


bedded in cement mortar (1:3) and pointing in
cement and laid on screeded bed to the required
pattern conform to Local Authority's requirement 64 M2

C Supply and lay 50mm thick concrete imprint with


approved pattern including concrete, formwork,
reinforcement and other necessary works all in
accordance with manufacturer's specification 490 M2

--------------------------------

D 225mm diameter precast scupper drain bedded and


jointed in cement and sand mortar (1:3), with
100mm thick concrete grade 15 surrounding and
laid to fall at 6.0m c/c including excavation, remove
surplus, part return, concrete, formwork, forming
outlet and other necessary work all as per
Engineer's detail drawing 82 M

Reinforced Concrete Pipe Culvert Drain

E To construct 450mm diameter class 'Y' concrete


pipe culvert surrounded with concrete grade 20,
225mm thick hardcore, 50mm thick lean concrete,
150mm thick concrete base complete with one layer
fabricated wire mesh BRC no. A6 and including
excavation, remove surplus, formwork, forming
outlet and other necessary works all as per
Engineer's detail drawing 63 M

F Ditto 600mm diameter pipe culvert 115 M

BQ/5/3 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Brickwall Sump

Brickwall sump of 900mm x 900mm (Internal


dimension) construct of 50mm thick lean
concrete, 150mm thick concrete mix 1:2:4
base reinforced with one layer BRC A6, 230mm
(min.) thick clay brickwall with 20mm thick
cement plaster on exposed surface, 150mm
(min.) thick grade 20 cast-in-situ concrete
slab complete with precast cover slab rebated
opening, 812mm x 610mm precast cover slab
(measured separately) and including all
necessary excavation, formwork, forming
outlet and other necessary work all as per
Engineer's detail :-

A Sump not exceeding 1.50m deep 22 No

B Ditto, exceeding 1.50m but not exceeding 3.00m


deep 1 No Rate Only

Brickwall sump of 750mm x 750mm (Internal


dimension) construct of 50mm thick lean
concrete, 150mm thick concrete mix 1:2:4
base reinforced with one layer BRC A6, 230mm
(min.) thick clay brickwall with 20mm thick
cement plaster on exposed surface, 150mm
(min.) thick grade 20 cast-in-situ concrete
slab complete with precast cover slab rebated
opening, 812mm x 610mm precast cover slab
(measured separately) and including all
necessary excavation, formwork, forming
outlet and other necessary work all as per
Engineer's detail :-

C Sump not exceeding 1.50m deep 12 No

D Ditto, exceeding 1.50m but not exceeding 3.00m


deep 1 No Rate Only

BQ/5/4 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Reinforced Concrete Sump

Reinforced concrete grade 20 sump with


internal dimension 900mm x 900mm consist of
150mm thick crusher run, 50mm thick lean
concrete, 200mm thick base and wall
reinforced with high tensile reinforcement bar
Y10, 20mm thick cement and sand plastering
to wall and all exposed concrete surface, mild
steel grating 1200mm x 1200mm (measured
separately) and including excavation,
formwork, forming outlet and other necessary
works all as per Engineer's detail :-

A Sump (S6) with depth exceeding 1.50m but not


exceeding 3.00m deep 1 No

Brick Retaining Wall

To construct brick retaining wall consists


225mm thick (min.) cement and sand brick,
50mm thick lean concrete, 300mm thick
concrete grade 20 base complete with one
layer BRC A10, Y-10 shear key at 200mm c/c
interval, 100mm diameter PVC pipe weep hole
with approved drainage material at 3000mm
c/c interval, 15mm thick cement plastering on
exposed brickwall surface and including
excavation, formwork and other necessary
work all as per Engineer's detail :-

B Brick retaining wall not exceeding 2.00m high 298 M

C Ditto, not exceeding 2.50m high 1 M Rate Only

D Do, not exceeding 3.00m high 1 M Rate Only

BQ/5/5 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Drainage

To supply and lay half round glazed ware drain


consist of 230mm (min.) thick clay brickwall
with 20mm thick plastering on exposed
surface, 300mm thick concrete grade 20 base,
125mm x 125mm concrete strut at 3000mm
c/c complete with 4 no. of Y10 mild steel bar,
R6 as link, 225mm x 125mm concrete mix
topping complete with rebated edge for
precast concrete slab (measured separately)
and including excavation, remove surplus,
formwork and other necessary works all as
per detail drawing :-

A 450mm wide with 300mm diameter half round


glazed ware drain not exceeding 1.00m deep (from
invert level) 1 M Rate Only

B Ditto exceeding 1.00m but not exceeding 1.50m


deep 1 M Rate Only

C Do exceeding 1.50m but not exceeding 2.10m deep


1 M Rate Only

Precast Box Culvert

D Supply and lay "HUME" or other approved


equivalent box culvert 1500mm x 1200mm high
(invert level) including excavation, lean concrete,
formwork and other necessary works all as per
Engineer's detail 158 M

Reinforced Concrete Step

Excavation

E Excavation for footing not exceeding 1.50m deep,


get out, part return, fill in and remove surplus
excavated materials from site 16 M3

F Ditto concrete step 4 M3

BQ/5/6 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Reinforced Concrete Step (Cont'd)

Reinforced Vibrated Concrete Grade 15 :-

A 50mm thick bed as blinding beneath footing 6 M2

B Ditto, beneath concrete step 18 M2

Reinforced Vibrated Concrete Grade 20 :-

C Footing 1 M3

D Stump 1 M3

E Concrete step 5 M3

High tensile steel rod reinforcement to


concrete :-

In stump

F 10mm diameter rod 140 Kg

In concrete step

G 10mm diameter rod 431 Kg

Fabric reinforcement cut to size :-

H One layer of B.R.C. No. A10 mesh fabric


reinforcement in footing (measured nett-no
allowance made for laps) 5 M2

Use and waste of sawn formwork :-

J To sides of stump 11 M2

K To sides of concrete step 350mm high 6 M

L To riser 165mm high 63 M

M To edge of concrete not exceeding 300mm high 16 M

BQ/5/7 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Metal Work

Galvanised Steel Grating

A Mild steel heavy duty steel grating with dimension


1000mm x 950mm wide consists of 50mm x 50mm
x 6mm thick L-shape angle frame embedded into
concrete complete with R8 steel rod, 15mm
diameter high tensile steel pin, 40 x 6mm mild steel
plate as bracing, 25mm x 6mm thick flat welded to
bracing all round and including other fixing
accessories, approved welding and other necessary
works all as per Engineer's detail 1 No

B Galvanised heavy duty steel grating with dimension


610mm x 450mm wide consists of 60mm x 60mm x
10mm thick L-shape steel frame embedded into
concrete complete with fish tail, 50 x 10mm thick
zinc galvanised plate as bracing, 40mm x 10mm
thick flat welded to bracing and including other
fixing accessories, approved welding and other
necessary works all as per Engineer's detail
2 No

C Galvanised catch pit steel grating with dimension


610mm x 250mm wide consists of 70mm x 70mm x
6mm thick L-shape angle frame embedded into
concrete complete with R8 steel rod, 15mm
diameter high tensile steel pin, 60 x 6mm mild steel
plate as bracing, 50mm x 12mm thick flat welded to
bracing all round and including other fixing
accessories, approved welding and other necessary
works all as per Engineer's detail 31 No

Catch Pitch

D To construct catch pitch with overall dimension


600mm x 350mm wide x 450mm deep complete
with mild steel grating (measured separately)
including excavation, concrete, formwork and other
necessary works all as per Engineer's detail 31 No

BQ/5/8 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Road Marking

Prepare and paint Class 1 quality white


Reflectorised Thermoplastic paint system on
premix road :-

A Continuity line 100mm wide 1 M Rate Only

B Stop line 150mm wide 6 M

C Parking line 100mm wide 1 M Rate Only

D Zebra crossing 2000mm x 600mm wide at 600mm


interval 24 M

E Pedestrian crossing 150mm wide 3 M

F Direction arrow 'one bend' 9 No

G Ditto 'straight' 16 No

H Do 'one bend and one straight' 1 No Rate Only

J Do 'two bend' 1 No Rate Only

Road Signs

K Retro reflextive 'Berhenti' sign complete with 75mm


mild steel post complete with approved painting and
embedded in 600mm x 600mm x 600mm high
concrete mix grade 1:3:6, 50mm thick lean
concrete and including excavation, clips, angles,
brackets, bolts and accessories all to Engineer's
approval 1 No

Reinforced Concrete Speed Hump

L Supply and install 1000mm wide reinforced concrete


speed hump including necessary reinforcement,
formwork and painting all as per Engineer's detailed
drawing 18 M

BQ/5/9 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Precast Cover Slab

A Supply and lay precast cover slab 600mm x 650mm


width x 50mm thick with concrete grade 20 mix,
reinforced with 10mm and 6mm diameter mild steel
reinforcement bar and lifting notch all as per
Engineer's detail 1 No Rate Only

Precast Compressed Concrete Slab

B Supply and lay precast compressed slab overall


dimension 610mm x 409mm x 50mm thick
complete with Y10 reinforcement bar, 50mm x
50mm x 5mm thick cast iron frame as bracing and
including other fixing accessories all according to
Engineer's detail 1 No Rate Only

C Ditto, 610mm x 812mm compressed slab ditto 34 No

Ancillary Works

D To demolish existing drain as described and


including cart away all debris from site
(approximate length: 150.00m) Item

E To demolish existing kerb and walkway as described


and including cart away all debris from site
(approximate length: 15.00m) Item

F To relocate existing electric post as per Engineer's


detail and instruction (Total post to be removed: 1
No) Item

BQ/5/10 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROAD & DRAINAGE

Bus Stand

A To construct bus stand overall dimension 7.20m x


2.80m x 3.10m high consist of 150mm diameter
stainless steel column complete with 300mm x
300mm x 12mm thick mild steel plate fixed on
concrete stump, aluminium composite panel roof
come with stainless steel support and fixing
accessories, 100mm diameter stainless steel bench
and barrier with both end fixed to floor in well
position, 1 no. of 400mm x 400mm bus stand
signage and including excavation, concrete,
formwork, reinforcement bar, floor finishes and
other necessary works all according to Architect's &
Engineer's detail drawing
1 No

Taxi Stand

B To construct taxi stand overall dimension 4.25m x


2.80m x 3.10m high consist of 150mm diameter
stainless steel column complete with 300mm x
300mm x 12mm thick mild steel plate fixed on
concrete stump, aluminium composite panel roof
come with stainless steel support and fixing
accessories, 100mm diameter stainless steel bench
and barrier with both end fixed to floor in well
position, 1 no. of 400mm x 400mm taxi stand
signage and including excavation, concrete,
formwork, reinforcement bar, floor finishes and
other necessary works all according to Architect's &
Engineer's detail drawing
1 No

BQ/5/11 TO COLLECTION :
BILL NO. 5
ROAD & DRAINAGE
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

COLLECTION

BQ/5/1

BQ/5/2

BQ/5/3

BQ/5/4

BQ/5/5

BQ/5/6

BQ/5/7

BQ/5/8

BQ/5/9

BQ/5/10

BQ/5/11

BQ/5/12 TO GENERAL SUMMARY :


BILL NO. 5
SEWERAGE RETICULATION
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SEWERAGE RETICULATION

Approved vitrified clay pipe as described extra


strength to BS 65 and 540 including all short
lengths, bends and jointing in spigot and
socket joint with flexible rubber rings to BS
2494 all in accordance with manufacturer's
specification :-

A 225mm diameter Class 'B' bedding to slope on and


including 525mm x 230mm thick compacted with
20mm crusher run bedding and haunching with
525mm x 415mm thick with approved selected
compacted backfill (minimum 300mm), detectable
marker tape laid on top of sewer pipe and including
excavation for pipe invert exceeding 1.50m but not
exceeding 3.00m deep, shoring, backfilling,
removing of surplus excavated material off site
9 M

Manhole

"HUME" or other approved equivalent precast


reinforced concrete chamber ring including
400mm thick chamber ring base with concrete
Grade 25, 150mm thick sulphate resisting
concrete surround and benching and
haunching to a slope of 1:12 gradient finished
of VCP half round channel at straight/bend
and junctions, minimum two layers of coal tar
epoxy/high alumina cement mortar applied on
chamber ring wall and taper top internally,
corrugated stainless steel step at 300mm
centres, 840mm x 840mm x 100mm heavy
duty ductile iron manhole cover and frame
bedding with 1:3 mortar mix including all
excavation, shoring, backfilling, removal of
surplus excavated material, formwork,
forming outlets and other necessary works all
as per Engineer's detail drawing :-

B Manhole with diameter 1220mm not exceeding


1.50m deep (Type A1) 1 No Rate Only

C Ditto exceeding 1.50m but not exceeding 3.00m


deep ditto 1 No

BQ/5/13 TO COLLECTION :
BILL NO. 5
SEWERAGE RETICULATION
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SEWERAGE RETICULATION (CONT'D)

A Allow for flushing the whole of the sewerage system


to the approval of the S.O. and local authority
representative Item

B Allow 10% of overall length of external sewerage


pipe for CCTV testing for sewerage networking Item

C Provide on completion six (6) copies of as-built


drawing for sewerage reticulation works certified by
Licensed Surveyor Item

D Allow for providing all necessary material and labour


for connection to sewerage treatment plant
Item

BQ/5/14 TO COLLECTION :
BILL NO. 5
SEWERAGE RETICULATION
(ALL PROVISIONAL)

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

COLLECTION

BQ/5/13

BQ/5/14

BQ/5/15 TO GENERAL SUMMARY :


BILL NO. 5
GENERAL SUMMARY

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

GENERAL SUMMARY Page No.

ROAD & DRAINAGE BQ/5/12

SEWERAGE RETICULATION BQ/5/15

BQ/5/16 TO FINAL SUMMARY :