Information on the Pressure Equipment Directive

Proline Promass 80/83/84


The following information relates to devices which have been examined in accordance with the
guidelines of the Pressure Equipment Directive 97/23/EC.

Type code
The code on the nameplate of the measuring device indicates whether the device in question has
been examined in accordance with the Pressure Equipment Directive::
Type code Definition

Promass 80F**-P/R/S/T/2/4***********

Promass 83F**-P/R/S/T/2/4***********

Promass 80M/E/I**-P/R***********
P/R/S/T/U/W/2/4 =
Promass 83M/E/I**-P/R*********** Approved in accordance with Pressure
Equipment Directive, Category III
Promass 80H**-U/W***********

Promass 83H**-U/W***********

Promass 84F/M/I**-P/R***********

Classification
The classification of the measuring device as per Art. 3 Par. 3, Cat. I/II or III is in accordance
with the PED 97/23/EC, Annex II, Tables 6 to 9..

Taking the flange-independent maximum pressure of the Promass into account, the following is
the maximum classification:

Device Application

Type Nominal Stable gases and fluids Unstable gases


diameter
Piping for gases, steams Piping for liquids
and liquids with a vapour with a vapour
pressure > 0.5 bar pressure < 0.5 bar

Group 1 Group 2 Group 1 Group 2


fluids fluids fluids fluids

Promass F DN 40...100 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III

Promass F DN 150...200 Cat. III Cat. II Cat. II Art. 3 Par. 3 Cat. III

Promass F DN 250...300 Cat. III Cat. II Cat. II Cat. I Cat. III

Promass F (HT) DN 50/80 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III

Promass M DN 40...80 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III

Promass E DN 40...50 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III

Promass I/H DN 40...50 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III

• Group 1 fluids:
explosive, flammable, toxic or oxidising media
• Group 2 fluids:
non-explosive, non-flammable, non-toxic and non-oxidising media

SD056D/06/en/01.05
50101403
Information on the Pressure Equipment Directive Proline Promass 80/83/84

Approval number
The following approval number for the type examination in accordance with Stoomwezen B.V.
applies to all the Promass measuring systems listed: PED/B/8035592

Material load diagrams of process connections


• Promass F → Page 2
• Promass M → Page 4
• Promass E → Page 5
• Promass H → Page 7
• Promass I → Page 8

Material load diagrams of process connections Promass F

Promass F:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80
• Alloy C-22
70

60 PN 63

50

40
PN 40
30

20

10 PN 16

0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]

F06-8xFxxxxx-05-xx-xx-xx-001

The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.

Promass F: [bar] [psi]


Flange connection to 110 1595
ANSI B16.5 90
Alloy C-22, Class 600
1305

Flange material: 80 1.4404/316L, Class 600 1160


• 1.4404/316L
70 1015
• Alloy C-22
60 870

50 Alloy C-22, Class 300 725

40 1.4404/316L, Class 300


580

30 435
Alloy C-22, Class 150
20 290
1.4404/316L, Class 150
10 145

0 0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]

F06-8xFxxxxx-05-xx-xx-xx-002

The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.

2 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive

Promass F: [bar]
Flange connection to 70
JIS B2238
60 63K

Flange material: 50
• 1.4404/316L
• Alloy C-22 40
40K
30

20
20K
10
10K
0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]

F06-8xFxxxxx-05-xx-xx-xx-003

The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.

Promass F: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.

# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!

Promass F:
Threaded union to
DIN 11864-1

Connection material:
• 1.4404/316L

F06-8xFxxxxx-05-xx-xx-xx-006

Promass F:
Flange connection to
DIN 11864-2

Flange material:
• 1.4404/316L

F06-8xFxxxxx-05-xx-xx-xx-007

Promass F:
Threaded union to ISO 2853

Connection material:
• 1.4404/316L

F06-8xFxxxxx-05-xx-xx-xx-008

Endress+Hauser 3
Information on the Pressure Equipment Directive Proline Promass 80/83/84

Material load diagrams of process connections Promass M

Promass M:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80
• Titan Grade 2
70

60 PN 63

50

40
PN 40
30

20

10 PN 16

0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]

F06-8xxxxxxx-05-xx-xx-xx-000

Promass M:
Flange connection to
ANSI B16.5

Flange material:
• 1.4404/316L
• Titan Grade 2

F06-8xxxxxxx-05-xx-xx-xx-001

4 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive

Material load diagrams of process connections Promass E

Promass E: [bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80

70

60 PN 63

50

40
PN 40
30

20
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]

F06-4xExxxxx-05-xx-xx-xx-000

Promass E:
Flange connection to
ANSI B16.5

Flange material:
• 1.4404/316L

F06-4xExxxxx-05-xx-xx-xx-001

Promass E: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.

# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!

Promass E:
Flange connection to
JIS B2238

Flange material:
• 1.4404/316L

F06-4xExxxxx-05-xx-xx-xx-002

Endress+Hauser 5
Information on the Pressure Equipment Directive Proline Promass 80/83/84

Promass E:
Threaded union to
DIN 11864-1

Connection material:
• 1.4404/316L

F06-4xExxxxx-05-xx-xx-xx-005

Promass E:
Flange connection to
DIN 11864-2

Flange material:
• 1.4404/316L

F06-4xExxxxx-05-xx-xx-xx-006

Promass E:
Threaded union to ISO 2853

Connection material:
• 1.4404/316L

F06-4xExxxxx-05-xx-xx-xx-007

6 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive

Material load diagrams of process connections Promass H

Promass H:
Flange connection to
EN 1092-1 (DIN 2501)

Flange material:
• 1.4301/304

Wetted parts:
• Zirkonium 702

F06-8xHxxxxx-05-xx-xx-xx-010

Promass H:
Flange connection to
ANSI B16.5

Flange material:
• 1.4301/304

Wetted parts:
• Zirkonium 702

F06-8xHxxxxx-05-xx-xx-xx-011

Promass H:
Flange connection to
JIS B2238

Flange material:
• 1.4301/304

Wetted parts:
• Zirkonium 702
F06-8xHxxxxx-05-xx-xx-xx-012

Endress+Hauser 7
Information on the Pressure Equipment Directive Proline Promass 80/83/84

Material load diagrams of process connections Promass I

Promass I:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4301/304 80

70
Wetted parts:
• Titan Grade 9 60 PN 63

50

40
PN 40
30

20

10 PN 16

0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]

F06-8xxxxxxx-05-xx-xx-xx-000

Promass I:
Flange connection to
ANSI B16.5

Flange material:
• 1.4301/304

Wetted parts:
• Titan Grade 9

F06-8xxxxxxx-05-xx-xx-xx-001

Promass I:
Flange connection to
JIS B2238

Flange material:
• 1.4301/304

Wetted parts:
• Titan Grade 9

F06-8xxxxxxx-05-xx-xx-xx-002

8 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive

Promass I: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.

# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!

Promass I:
Threaded union to
DIN 11864-1

Connection material:
• Titan Grade 2

F06-8xIxxxxx-05-xx-xx-xx-001

Promass I:
Threaded union to
DIN 11864-2

Connection material:
• Titan Grade 2

F06-8xIxxxxx-05-xx-xx-xx-002

Promass I:
Threaded union to
ISO 2853

Connection material:
• Titan Grade 2

F06-8xxxxxxx-05-xx-xx-xx-005

Endress+Hauser 9
Information on the Pressure Equipment Directive Proline Promass 80/83/84

Additional information
All measuring devices undergo a pressure unit test with at least 1.5 times the maximum pressure
rating. For more details, please refer to the 2.3 certificate provided.

If the device is delivered with detached process connections (only for Promass M), these connec-
tions have to be included in the piping pressure test.

The sensor housing protects the inner electronics and mechanics and is filled with dry nitrogen.
It does not serve as secondary containment (only for Promass E). A pressure of 5 bar for pressure
resistance can be given as guidance for the housing.

# Warning!
In case a danger of measuring tube failure exists due to process characteristics, e.g. with
corrosive process fluids, a mechanical overload of the housing can occur which could lead to
a housing failure and accordingly is connected with an increased danger potential (only for
Promass E). It is therefore of high importance to clarify the compatibility of process fluid with
the measuring tube material and to observe the specified maximum process pressure.