Type code
The code on the nameplate of the measuring device indicates whether the device in question has
been examined in accordance with the Pressure Equipment Directive::
Type code Definition
Promass 80F**-P/R/S/T/2/4***********
Promass 83F**-P/R/S/T/2/4***********
Promass 80M/E/I**-P/R***********
P/R/S/T/U/W/2/4 =
Promass 83M/E/I**-P/R*********** Approved in accordance with Pressure
Equipment Directive, Category III
Promass 80H**-U/W***********
Promass 83H**-U/W***********
Promass 84F/M/I**-P/R***********
Classification
The classification of the measuring device as per Art. 3 Par. 3, Cat. I/II or III is in accordance
with the PED 97/23/EC, Annex II, Tables 6 to 9..
Taking the flange-independent maximum pressure of the Promass into account, the following is
the maximum classification:
Device Application
Promass F DN 150...200 Cat. III Cat. II Cat. II Art. 3 Par. 3 Cat. III
Promass F (HT) DN 50/80 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III
Promass I/H DN 40...50 Cat. II Cat. I Cat. II Art. 3 Par. 3 Cat. III
• Group 1 fluids:
explosive, flammable, toxic or oxidising media
• Group 2 fluids:
non-explosive, non-flammable, non-toxic and non-oxidising media
SD056D/06/en/01.05
50101403
Information on the Pressure Equipment Directive Proline Promass 80/83/84
Approval number
The following approval number for the type examination in accordance with Stoomwezen B.V.
applies to all the Promass measuring systems listed: PED/B/8035592
Promass F:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80
• Alloy C-22
70
60 PN 63
50
40
PN 40
30
20
10 PN 16
0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]
F06-8xFxxxxx-05-xx-xx-xx-001
The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.
30 435
Alloy C-22, Class 150
20 290
1.4404/316L, Class 150
10 145
0 0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]
F06-8xFxxxxx-05-xx-xx-xx-002
The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.
2 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive
Promass F: [bar]
Flange connection to 70
JIS B2238
60 63K
Flange material: 50
• 1.4404/316L
• Alloy C-22 40
40K
30
20
20K
10
10K
0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 [°C]
F06-8xFxxxxx-05-xx-xx-xx-003
The values for the temperature range from +200 °C to +350 °C are exclusively valid for
Promass F (HT) high-temperature version.
Promass F: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.
# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!
Promass F:
Threaded union to
DIN 11864-1
Connection material:
• 1.4404/316L
F06-8xFxxxxx-05-xx-xx-xx-006
Promass F:
Flange connection to
DIN 11864-2
Flange material:
• 1.4404/316L
F06-8xFxxxxx-05-xx-xx-xx-007
Promass F:
Threaded union to ISO 2853
Connection material:
• 1.4404/316L
F06-8xFxxxxx-05-xx-xx-xx-008
Endress+Hauser 3
Information on the Pressure Equipment Directive Proline Promass 80/83/84
Promass M:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80
• Titan Grade 2
70
60 PN 63
50
40
PN 40
30
20
10 PN 16
0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]
F06-8xxxxxxx-05-xx-xx-xx-000
Promass M:
Flange connection to
ANSI B16.5
Flange material:
• 1.4404/316L
• Titan Grade 2
F06-8xxxxxxx-05-xx-xx-xx-001
4 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive
Promass E: [bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4404/316L 80
70
60 PN 63
50
40
PN 40
30
20
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]
F06-4xExxxxx-05-xx-xx-xx-000
Promass E:
Flange connection to
ANSI B16.5
Flange material:
• 1.4404/316L
F06-4xExxxxx-05-xx-xx-xx-001
Promass E: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.
# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!
Promass E:
Flange connection to
JIS B2238
Flange material:
• 1.4404/316L
F06-4xExxxxx-05-xx-xx-xx-002
Endress+Hauser 5
Information on the Pressure Equipment Directive Proline Promass 80/83/84
Promass E:
Threaded union to
DIN 11864-1
Connection material:
• 1.4404/316L
F06-4xExxxxx-05-xx-xx-xx-005
Promass E:
Flange connection to
DIN 11864-2
Flange material:
• 1.4404/316L
F06-4xExxxxx-05-xx-xx-xx-006
Promass E:
Threaded union to ISO 2853
Connection material:
• 1.4404/316L
F06-4xExxxxx-05-xx-xx-xx-007
6 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive
Promass H:
Flange connection to
EN 1092-1 (DIN 2501)
Flange material:
• 1.4301/304
Wetted parts:
• Zirkonium 702
F06-8xHxxxxx-05-xx-xx-xx-010
Promass H:
Flange connection to
ANSI B16.5
Flange material:
• 1.4301/304
Wetted parts:
• Zirkonium 702
F06-8xHxxxxx-05-xx-xx-xx-011
Promass H:
Flange connection to
JIS B2238
Flange material:
• 1.4301/304
Wetted parts:
• Zirkonium 702
F06-8xHxxxxx-05-xx-xx-xx-012
Endress+Hauser 7
Information on the Pressure Equipment Directive Proline Promass 80/83/84
Promass I:
[bar]
Flange connection to
EN 1092-1 (DIN 2501) 100
PN 100
90
Flange material:
• 1.4301/304 80
70
Wetted parts:
• Titan Grade 9 60 PN 63
50
40
PN 40
30
20
10 PN 16
0
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 [°C]
F06-8xxxxxxx-05-xx-xx-xx-000
Promass I:
Flange connection to
ANSI B16.5
Flange material:
• 1.4301/304
Wetted parts:
• Titan Grade 9
F06-8xxxxxxx-05-xx-xx-xx-001
Promass I:
Flange connection to
JIS B2238
Flange material:
• 1.4301/304
Wetted parts:
• Titan Grade 9
F06-8xxxxxxx-05-xx-xx-xx-002
8 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive
Promass I: The maximum process pressure for the Tri-Clamp connection is 16 bar. However, the load limit is
Tri-Clamp defined additionally by the material properties of the outer clamp used. This clamp is not included
Process connection in the scope of delivery.
# Warning!
Before opening the outer clamp make sure to relieve the pressure from the pipeline!
Promass I:
Threaded union to
DIN 11864-1
Connection material:
• Titan Grade 2
F06-8xIxxxxx-05-xx-xx-xx-001
Promass I:
Threaded union to
DIN 11864-2
Connection material:
• Titan Grade 2
F06-8xIxxxxx-05-xx-xx-xx-002
Promass I:
Threaded union to
ISO 2853
Connection material:
• Titan Grade 2
F06-8xxxxxxx-05-xx-xx-xx-005
Endress+Hauser 9
Information on the Pressure Equipment Directive Proline Promass 80/83/84
Additional information
All measuring devices undergo a pressure unit test with at least 1.5 times the maximum pressure
rating. For more details, please refer to the 2.3 certificate provided.
If the device is delivered with detached process connections (only for Promass M), these connec-
tions have to be included in the piping pressure test.
The sensor housing protects the inner electronics and mechanics and is filled with dry nitrogen.
It does not serve as secondary containment (only for Promass E). A pressure of 5 bar for pressure
resistance can be given as guidance for the housing.
# Warning!
In case a danger of measuring tube failure exists due to process characteristics, e.g. with
corrosive process fluids, a mechanical overload of the housing can occur which could lead to
a housing failure and accordingly is connected with an increased danger potential (only for
Promass E). It is therefore of high importance to clarify the compatibility of process fluid with
the measuring tube material and to observe the specified maximum process pressure.
10 Endress+Hauser
Proline Promass 80/83/84 Information on the Pressure Equipment Directive
Endress+Hauser 11
www.endress.com/worldwide
SD056D/06/en/01.05
50101403
FM+SGML 6.0