Sei sulla pagina 1di 7

Available online at www.sciencedirect.

com
Available online at www.sciencedirect.com

ScienceDirect
ScienceDirect
Procedia
Available Manufacturing
online 00 (2018) 407–413
atatwww.sciencedirect.com
Available
Procediaonline www.sciencedirect.com
Manufacturing 00 (2018) 407–413 www.elsevier.com/locate/procedia
www.elsevier.com/locate/procedia
ScienceDirect
ScienceDirect 
Procedia Manufacturing 22 (2018) 399–405
Procedia Manufacturing 00 (2017) 000–000
www.elsevier.com/locate/procedia
11th International Conference Interdisciplinarity in Engineering, INTER-ENG 2017, 5-6 October
11th International Conference Interdisciplinarity in Engineering,
2017, Tirgu-Mures, Romania INTER-ENG 2017, 5-6 October
2017, Tirgu-Mures, Romania
Simultaneous effect of nano and micro silica on corrosion behaviour
Simultaneous effect of nanoInternational
and micro silica 2017,
on corrosion
MESIC 2017,behaviour
ofManufacturing
reinforcementEngineering Society
in concrete containing Conference
cement strength 28-30 June
grade of C-
of reinforcement in concrete containing cement strength grade of C-
2017, Vigo (Pontevedra), Spain
525
Costing models for capacity optimization 525 in Industry 4.0: Trade-off
Hamid Eskandari-Naddafa,a,*, Ali Ziaei-Niaaa
betweenHamid
used Eskandari-Naddaf
capacity and operational efficiency
*, Ali Ziaei-Nia
Department of Civil Engineering, Hakim Sabzevari University, Sabzevar, Iran.
Department of Civil
a Engineering, Hakim
a,* Sabzevari University, Sabzevar, Iran.
A. Santana , P. Afonso , A. Zanin , R. Wernke b b

a
University of Minho, 4800-058 Guimarães, Portugal
Abstract b
Unochapecó, 89809-000 Chapecó, SC, Brazil
Abstract
The present study investigated the changes in the effect of additive nano-silica replacing micro-silica to reduce corrosion rate of
The present
steel study investigated
in the concrete the changes
made of C-525 cementininthe effect of environment,
a corrosive additive nano-silica
and alsoreplacing micro-silica
the optimum to reduce
combination corrosion
of these rate of
additives in
steel in theconcrete
reinforced
Abstract concreteformadethe of C-525 cement
production in a corrosive
of reinforced concreteenvironment, and also the
with high resistance optimum of
to corrosion combination of these To
the reinforcement. additives in
this end,
7reinforced
series of concrete
cylindricalforcorrosion
the production
samplesofwere
reinforced concrete
prepared, whichwith high resistance
comprised to corrosion
a base design of the reinforcement.
and 6 designs To this end,
of various combinations of
7micro
seriesand
Under of nano
the cylindrical
silica,corrosion
concept weighing
of samples were
a constant
"Industry 4.0", 11%prepared,
in total which
production the comprised
ofprocesses
weightwill a be
basepushed
of cement design
used inand 6bedesigns
each
to sample. ofSamples
variousinterconnected,
increasingly combinations
were placed inofa
micro and nano
3.5% salt-water
information silica,
solution
based weighing
on a and a constant
realunderwent 11%
time basisvarious in total of the
electrochemical
and, necessarily, weight
much of
tests, cement
including
more used in
corrosion
efficient. each sample.
In thispotential Samples
context,(OCP), were
linear
capacity placed in a
polarization
optimization
3.5%
(LPR), salt-water
impedance solution and underwent
spectroscopy (EIS), various
and Tafel electrochemical
polarization tests,
test. The including
results corrosion
obtained potential
suggested (OCP), linear
combined use ofpolarization
1.6% nano
goes beyond the traditional aim of capacity maximization, contributing also for organization’s profitability and value.
(LPR),
and 9.4% impedance spectroscopy
micro-silica for (EIS),
achieving the and
most Tafel polarization
appropriate test. The results obtaineduseful
suggested combined use of 1.6% nano
Indeed,
and
lean
9.4% reduction
management
micro-silica
and continuous
for achieving theofmost
improvement approaches suggest capacity optimization instead the
cost considering the increased life of concrete structures
appropriate cost considering the increased useful life of concrete structures and the
and of
optimum in rate of corrosion concrete.
maximization.
optimum The
reduction study of
in Published capacity
rate of corrosion optimization
of concrete. and costing models is an important research topic that deserves
© 2018 The Authors. by Elsevier B.V.
contributions
© from both
2018 The Authors.
Peer-review
the practical
Published
under responsibility by andB.V.
of Elsevier
theoretical
the scientific
perspectives. This paper presents and discusses a mathematical
committee of the 11th International Conference Interdisciplinarity in
©
model2018
Peer-reviewThe
for Authors.
capacity Published
management by Elsevier
based B.V.
under responsibility of the scientific committee of the models
on different costing (ABC and
11th International TDABC).Interdisciplinarity
Conference A generic model in has been
Engineering.under
Peer-review responsibility of the scientific committee of the 11th International Conference Interdisciplinarity in Engineering.
developed
Engineering. and it was used to analyze idle capacity and to design strategies towards the maximization of organization’s
value. TheConcrete,
Keywords: trade-off capacity
Corrosion, maximization
Electrochemical vs operational efficiency is highlighted and it is shown that capacity
methods.
Keywords: Concrete,
optimization mightCorrosion, Electrochemical
hide operational methods.
inefficiency.
© 2017 The Authors. Published by Elsevier B.V.
Peer-review under responsibility of the scientific committee of the Manufacturing Engineering Society International Conference
2017.

Keywords: Cost Models; ABC; TDABC; Capacity Management; Idle Capacity; Operational Efficiency

1. Introduction
* Corresponding author. Tel.: +98-514-401-3386; fax: 98-514-401-2789.
* Corresponding
E-mail address:author. Tel.: +98-514-401-3386; fax: 98-514-401-2789.
Hamidiisc@yahoo.com
The cost
E-mail of idle
address: capacity is a fundamental information for companies and their management of extreme importance
Hamidiisc@yahoo.com
in modern©production
2351-9789 systems.
2018 The Authors. In general,
Published it isB.V.
by Elsevier defined as unused capacity or production potential and can be measured
in several©under
2351-9789
Peer-review ways: tons of production,
2018responsibility
The Authors. Published
of available
by Elsevier
the scientific B.V.hours
committee of manufacturing,
of the 11th etc. The
International Conference management
Interdisciplinarity of the idle capacity
in Engineering.
Peer-review underTel.:
* Paulo Afonso. responsibility
+351 253 of the761;
510 scientific committee
fax: +351 253 604of741
the 11th International Conference Interdisciplinarity in Engineering.
E-mail address: psafonso@dps.uminho.pt

2351-9789 © 2017 The Authors. Published by Elsevier B.V.


Peer-review under responsibility of the scientific committee of the Manufacturing Engineering Society International Conference 2017.
2351-9789 © 2018 The Authors. Published by Elsevier B.V.
Peer-review under responsibility of the scientific committee of the 11th International Conference Interdisciplinarity in Engineering.
10.1016/j.promfg.2018.03.062
400 Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405
408 Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413

1. Introduction

According to The need for manufacturers in different parts of the world to produce concrete with higher corrosion
resistance to build structures in exposed to corrosive ions at optimal cost, minimum damage to the environment,
requires materials that are usually available everywhere. Caused by exposure to chloride ions is considered the main
destructive factor in reinforced concrete structures [1-5]. The ability of a substance to resist displacement of ions
usually depends on electrical resistivity, and inversely proportional to concrete resistivity [6]. Researchers have
demonstrated that concentration of corrosive materials and environmental conditions [7], percentage of micro-silica
[8] and nano-silica [9] additives can reduce corrosion in concrete [10]. The interest in these additives is because of
their advantages over other corrosion protection methods including diversity in type and amount and lower costs [11,
12]. Although the effects of micro and nano silica in increasing corrosion resistance of ordinary concretes is well-
known [13], their combined effects and optimum amounts have not yet been studied. Moreover, since these tests are
non-destructive, performing several different electrochemical corrosion tests plus one destructive test in a chloride
medium, instead of a single test, will produce better and more acceptable results and different parameters for
identifying potential and rate of corrosion [14, 15].
It should be noted that in the research conducted on the combination of micro and nano silica binary at different
doses in the manufacture of concrete with cement 525 with the aim of reducing the corrosion rate from chlorine ion
and reaching their optimal consumption together they are not used. For this purpose, 3 non-destructive tests
(corrosion potential OCP; linear polarization LPR; and impedance spectroscopy EIS) and Tafel polarization
destructive test were carried out on 7 series of test samples, so that different dimensions of the effects of these
additives can be accurately studied and compared.

2. Experimental

2.1. Materials properties and mixture proportions

To perform the corrosion test, seven 100 × 150 mm cylindrical concrete samples reinforced with 18Ø ribbed
polished steel bars were exposed to salt ion attack, such that 70 mm of the steel bar length was placed in the middle
of cylindrical samples (epoxy-free) and was tested after the standard 90 days curing age. Portland cement II-525
kg/cm2 of standard specification [16], and river-type aggregate of 9 mm maximum diameter, with standard poly-
carboxylic superplasticizer [17] were used. Nano-silica (NSF) of 20gr/cm3 density was used as an emulsion
suspended-in-water, with 29.6-31% silica, pH of 9.6-10.2, maximum viscosity of 7, and specific area of 200-240
m2/gr. Micro-silica powder (MSF) of specific area 20-25 m2/gr, was used as spherical particles of 229 nm diameter
and amorphous structure according to standards [18].
Samples were made from cement grade 350 kg/m3, W/C = 0.44 and superplasticizer weight 0.36% of cement
weight. Total percentage weight of MSF and NSF mixture in each sample was 0.11 of weight of cement used, which
was within the range recommended by some researchers as the appropriate amount of micro-silica for enhancing
certain endurance properties of concrete [19]. Mix 1 (control mixture) was prepared without nano or micro silica.
The difference in mixture designs was in the proportion of additives used, such that in mix2 to mix7 designs, the
following percentages of NSF and MSF were respectively used: (0.111, 0.0), (0.095, 0.016), (0.079, 0.032), (0.055,
0.055), (0.032, 0.079), and (0.0, 0.111).

3. Methods

First, to find natural corrosion potential of samples according to standards [20], OCP test was performed at
temperature of 25 °C, using a potentiostat (model ACM Instrument-Gill AC) and platinum counter electrode of 2
cm2 area in 3-electrode method.
Then, samples were subjected to Linear Polarization Resistance (LPR) test with DC current and potential sweep
range on from -10 mV cathode surface to +10 mV anode [21] compared to corrosion potential found in OCP test.
Next, current was found from resistance using Stern-Geary equation [21-23]. The corroded mass and ultimately
corrosion rate were found according to ASTM G102-89 standard and Faraday's current law [10, 23].
Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405 401
Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413 409

To find corrosion rate, EIS test was performed with AC current using equivalent circuit used by A Batysta [24] at
10 mV [15]. This test was carried out over a broad frequency range from 0.0001 to 100 KHz [15, 25], ignoring the
negligible value of Rs (about 3-10 Ωcm2).
Lastly, the destructive Tafel polarization test was performed at sweep speed of 60 Mv/sec. In the Tafel plots, the
potential values imposed on a sample were based on standards, ranging from -250 mV cathode to +250 mV anode,
compared to values obtained in OCP test for that sample [10].

4. Results and discussion

The results of OCP and LPR tests are presented in Fig. 1. It can be seen that from control mix to mix2,
replacement of micro-silica in the cement by 11% leads to reduced corrosion rate in LPR test by 3.9 times. Also,
from mix2 to mix3, by replacing micro-silica with 1.6% nano-silica, corrosion rate and potential will reduce by 5
and 12.5 times respectively. Comparison of mix7 and mix2 shows that complete replacement of MSF with NSF will
result in improved electrochemical properties of concrete in 90-day curing age. This improvement may have been
due to the filling ability and reduced ion penetration due to greater pozzolanic reactions of nano-silica compared to
micro-silica [26]. Some researchers have argued that smaller particles create a relatively denser structure and greater
discrete cavities in the concrete [8]. According to the above argument, design 3 will be the best overall choice.

0.016 0
LPR - corrosion rate (mm/year)

0.014
-100
0.012
-200
0.01

OCP (mV )
LPR- corrosion rate
0.008 -300
OCP
0.006
-400
0.004
-500
0.002
0 -600
0 2 4 6 8
NSF→ Mix Number ←MSF

Fig. 1. Matching values of OCP test and corrosion rate compared to LPR test in terms of micro-nano proportions used.

The results from EIS, LPR, and Tafel tests for all designs are presented in Fig. 2. Comparing control mix and
mix2 shows improvement in corrosion resistance by 5.85 and 2.5 times due to increased Icorr and total resistance (Z).
Moreover, corrosion current and total resistance (Z) obtained in Tafel and EIS tests improved by 2 and 8.8 times
respectively, to reduce corrosion rate. Recent studies have shown that addition of different doses of MSF and FGP to
concrete was able to reduce Icorr by a maximum of 34% [8], and also showed that design 3 produces the best results.
As a general trend, increasing Rs (Rp, Rc, and Rct) is clearly seen in Fig. 3. The increase in electrical resistance
and decrease in corrosion rate are due to MSF replacement with cement, which has been cited and explained by
researchers [8, 27-29]. OCP test does not show an ascending trend in corrosion potential in mix2 compared to
control mix, which may be due to the error in this method in some cases. An increase in values of R is observed in
mix3 compared to mix2, and this figure also confirms superiority of design 3, which means replacement of
equivalent weight of cement with 1.6% nano and 9.5% micro silica can produce better corrosion results.
402 Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405
410 Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413

0.0016 220
LPR - i
0.0014 Tafel - I corr
Total Impedance - Z
170

EIS - Z (K Ω.cm2 )
0.0012 Reality Impedance (Z')
I ( mA/cm2 )
Imaginary Impedance (Z'')
0.001 120
0.0008
0.0006 70

0.0004
20
0.0002
0 -30
0 1 2 3 4 5 6 7 8
NSF→ Mix Number ←MSF

Fig. 2. Comparing the results of impedance from total EIS test with I found in Tafel polarization and LPR tests in terms of proportions of micro-
nano used.

1.0E+07 EIS - Rct


0.1
EIS - R c
1.0E+06 LPR - Rp
0.01
EIS - CPE dl 0.001
EIS - R (k Ω.cm2)

1.0E+05 EIS - CPE c


0.0001

EIS - CPE (μF )


1.0E+04
0.00001
1.0E+03
0.000001
1.0E+02
0.0000001
1.0E+01 1E-08
1.0E+00 1E-09
1.0E-01 1E-10
0 1 2 3 4 5 6 7 8
NSF→ Mix number ←MSFF

Fig. 3. The trend of changes in resistance (Rp) obtained in LPR test and values found for resistance and capacitors in EIS test in relation to micro-
nano proportions (Rct=Rcharge transfer; Rc= Rcoute; Rp=Rpolarization; CPEdl= CPE double layer; CPEc=CPEconcrete (coute)).

Comparison of tests performed on all samples shows that replacement of nano-silica of more than 1.6% with
micro-silica powder does not produce a positive effect in reducing corrosion rate, and that because of the optimum
balance in the binary combination of NSF and MSF, mix3 produces the best results. The reasons for limited use of
nano-silica include reduced density, relatively greater absorption of water, and clear porosity due to use of nano-
silica in exceeding certain dosage [30, 31]. It has been argued that concurrent use of these two provides greater
corrosion resistance than using them individually; however, increasing use of nano and micro (even in combination)
will not necessarily improve endurance property of concrete [26, 32], which confirms the above results. Also, by
using relatively high doses of nano alone, electrical resistance can be observed [33]. Previous studies have shown
that in combination of nano and micro, even tiny amounts of nano-silica produce substantial effects in increasing
charge transfer resistance and resistance against corrosion. As a result, given the higher cost of nano silica, we found
Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405 403
Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413 411

its optimal use which will be economically optimal in terms of reducing both the cost of production and increase
lifespan of concrete structures constructed with this consumable dose.
The electrical properties of double-layer can have a significant role in chloride-induced corrosion in the
reinforced concrete steel bars [34]. This trend is due to an electro-capillary process and the interaction between pore
walls and pore solution, which creates an electrical absorptivity that slows down chloride ion penetration [35, 36]. A
highly important parameter of electrical double layer is the pore size, such that any changes in pore size cause a
substantial change in concentration of chloride inside the pores [35]. Hence, reduced diameter of pores, and thus
penetration of chloride ions, can be considered a reason for increasing R and relatively high level of resistance
against corrosion, and provides another explanation for increased corrosion resistance in mix3 compared to other
mixture designs (Fig. 3). Given the above discussion, due to their matching hydration rate on the one hand, and
creating better bond between cement micro-grains due to their optimal mixing including cement powder, NSF, and
MSF on the other hand, combination of NSF and MSF reduces diameter of pores and closes the connections between
them, resulting in increased density of concrete, and ultimately reduced penetration of chloride ions into concrete,
and ions reaching surface of steel bars to cause corrosion.

200 0.7
180
0.6
160
140 0.5
EIS - Z (KΩ.cm2 )

120
0.4

EIS - n
100
0.3
80
60 0.2
EIS - Total Impedance (Z)
40
EIS (n2) 0.1
20
EIS (n1)
0 0
0 2 4 6 8
NSF→ ←MSF
Mix number

Fig. 4. Changes in parameter n and total impedance Corrosion rate found in LPR test, and potential corrosion in OCP test, in relation to
proportions of nano-micro used.

The value of parameter n associated with CPE (usually less 1 [37], and generally ignored [38]) has a particular
trend here. Previous studies have shown that value of n can be considered as a criterion for surface toughness, and
test results indicate that value of n increases with increasing surface toughness [39]. Interestingly, Fig. 4 shows that
corrosion resistance is the highest, and values of n1 (steel surface) and n2 (concrete surface) are the lowest and the
highest, respectively, in mix3. Perhaps, n can be an effective parameter in reducing corrosion rate, and n1 compared
to n2 is more effective in increasing corrosion resistance in mix3 compared to other designs.

5. Conclusion

1- As a general trend, for cement 525, replacement of micro-silica with values of nano-silica greater than 1.6%
adversely affects reduction in corrosion rate. This amount varies according to type of cement and other
conditions.
2- Among the 4 tests used, OCP test lacks sufficient accuracy and cannot be used alone.
404 Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405
412 Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413

3- By increasing specific surface or reducing diameter of nano particles, the optimum range of silica particles
against reduction in concrete corrosion rate can be reduced
4- Compared to other additives, micro and nano silica compensate weaknesses of each other, and perform better,
which may be due to compatibility of their specific surface and hydration rate.
5- Although using nano alone produces better chlorine ion corrosion resistance results compared to using micro
alone, their binary combination produces better results still compared to their use separately.

References

[1] P.-C. Aïtcin, High performance concrete. 2011: CRC Press.


[2] H. Gerengi, Y Kocak, A. Jazdzewska, M. Kurtay, H. Durgun, Electrochemical investigations on the corrosion behaviour of reinforcing steel
in diatomite-and zeolite-containing concrete exposed to sulphuric acid. Construction and Building Materials. 49 (2013) 471-477.
[3] B. Pradhan, B. Bhattacharjee, Rebar corrosion in chloride environment. Construction and Building Materials. 25(5) (2011) 2565-2575.
[4] B. Pradhan, B. Bhattacharjee, Performance evaluation of rebar in chloride contaminated concrete by corrosion rate. Construction and
building materials. 23(6) (2009) 2346-2356.
[5] E. Güneyisi, E. Güneyisi, K. Mermerdaş, Corrosion behavior of reinforcing steel embedded in chloride contaminated concretes with and
without metakaolin. Composites, Corrosion behavior of reinforcing steel embedded in chloride contaminated concretes with and without
metakaolin. Composites Part B: Engineering. 45(1) (2013) 1288-1295.
[6] K. Hornbostel, C.K. Larsen, and M.R. Geiker, Relationship between concrete resistivity and corrosion rate–a literature review. Cement and
Concrete Composites. 39 (2013) 60-72.
[7] Z. Wang, JM LaFave, J Trybulski, D Lovett, J. Lima, D.W. Pfeifer, Corrosion of rebar in concrete under cyclic freeze–thaw and Chloride
salt action. Construction and Building Materials. 53 (2014) 40-47.
[8] J. Shi, W. Sun, Effects of phosphate on the chloride-induced corrosion behavior of reinforcing steel in mortars. Cement and Concrete
Composites. 45 (2014) 166-175.
[9] O. Keleştemur, B. Demirel, Corrosion behavior of reinforcing steel embedded in concrete produced with finely ground pumice and silica
fume. Construction and Building Materials. 24(10) (2010) 1898-1905.
[10] F.U.A. Shaikh, S.W. Supit, Chloride induced corrosion durability of high volume fly ash concretes containing nano particles. Construction
and Building Materials. 99 (2015) 208-225.
[11] T. Bremner, et al., ACI 222R-01 protection of metals in concrete against corrosion, in American Concrete Institute, Farmington Hills2001.
[12] T. Söylev, M. Richardson, Corrosion inhibitors for steel in concrete: State-of-the-art report. Construction and Building Materials. 22(4)
(2008) 609-622.
[13] S. Qian, D. Cusson, Electrochemical evaluation of the performance of corrosion-inhibiting systems in concrete bridges. Cement and
Concrete Composites. 26(3) (2004) 217-233.
[14] H. Müller, Constitutive modelling of high strength/high performance concrete. FIB Bulletin. 42 (2008).
[15] V. Bouteiller, C. Cremona, V. Baroghel-Bouny, A. Maloula, Corrosion initiation of reinforced concretes based on Portland or GGBS
cements: Chloride contents and electrochemical characterizations versus time. Cement and Concrete Research. 42(11) (2012) 1456-1467.
[16] C150, A., Standard Specification of Portland Cement, 2012, ASTM International West Conshohocken, PA.
[17] C494, A., Standard Specification for Chemical Admixtures for Concrete, 2004, ASTM International West Conshohocken, PA.
[18] C1240, A., Standard Specification for Silica Fume Used in Cementitious Mixtures, 2015, ASTM International, West Conshohocken.
[19] Song, H.-W., et al., An estimation of the diffusivity of silica fume concrete. Building and Environment, 2007. 42(3): p. 1358-1367.
[20] (ASTM), A.S.f.T.a.M., Standard Test Method for Sampling and Testing Fly Ash or Natural Pozzolans for Use in Portland-Cement Concrete,
ASTM C311-05: Pennsylvania.
[21] H. Böhni, Corrosion in reinforced concrete structures. 2005: Elsevier.
[22] B. Elsener, Corrosion inhibitors for steel in Concrete, Institute of Materials: Carlton House Terrace, London, 2001.
[23] G102., A., Standard Practice for Calculation of Corrosion Rates and Related Information From Electrochemical Measurements, 1999.
[24] G. Blanco, A. Bautista, and H. Takenouti, EIS study of passivation of austenitic and duplex stainless steels reinforcements in simulated pore
solutions. Cement and Concrete Composites. 28(3) (2006) 212-219.
[25] M.-G. Olivier, M. Poelman, Recent Researches in Corrosion Evaluation and Protection: Use of Electrochemical Impedance Spectroscopy
(EIS) for the Evaluation of Electrocoatings Performances. Recent researches in Corrosion Evaluation and Protection, 2012.
[26] J. Dotto, et al., Influence of silica fume addition on concretes physical properties and on corrosion behaviour of reinforcement bars. cement
and concrete composites. 26(1) (2004) 31-39.
[27] S.A. Civjan, JM LaFave, J Trybulski, D Lovett, J. Lima, D.W. Pfeifer, Effectiveness of corrosion inhibiting admixture combinations in
structural concrete. Cement and Concrete composites. 27(6) (2005) 688-703.
[28] J. Sobhani, M. Najimi, Electrochemical impedance behavior and transport properties of silica fume contained concrete. Construction and
Building Materials. 47 (2013) 910-918.
[29] A.R. Ghasemi, T. Parhizkar, A. Ramezanianpour. Influence of colloidal nano-SiO2 addition as silica fume replacement material in
properties of concrete. in Proceeding, Second international conference on sustainable construction materials and technologies. 2010.
[30] L. Senff, D. Hotza, W.L. Repette, V.M. Ferreira, J.A. Labrincha, Mortars with nano-SiO 2 and micro-SiO 2 investigated by experimental
design. Construction and Building Materials. 24(8) (2010) 1432-1437.
Hamid Eskandari-Naddaf et al. / Procedia Manufacturing 22 (2018) 399–405 405
Hamid Eskandari-Naddaf and Ali Ziaei-Nia / Procedia Manufacturing 00 (2018) 407–413 413

[31] A.M. Said, M.S. Zeidan, M.T. Bassuoni, Y. Tian, Properties of concrete incorporating nano-silica. Construction and Building Materials. 36
(2012) 838-844.
[32] M.Gesoglu, E. Güneyisi, D.S. Asaad, G.F. Muhyaddin, Properties of low binder ultra-high performance cementitious composites:
Comparison of nanosilica and microsilica. Construction and Building Materials. 102 2016 706-713.
[33] H. Madani, A Bagheri, T Parhizkar, A. Raisghasemi, Chloride penetration and electrical resistivity of concretes containing nanosilica
hydrosols with different specific surface areas. Cement and Concrete Composites. 53 (2014) 18-24.
[34] S. Chatterji, M. Kawamura, Electrical double layer, ion transport and reactions in hardened cement paste. Cement and Concrete Research,.
22(5) (1992) 774-782.
[35] P. Nguyen, O. Amiri, Study of electrical double layer effect on chloride transport in unsaturated concrete. Construction and Building
Materials. 50 (2014) 492-498.
[36] H. Friedmann, O Amiri, A Aıt-Mokhtar, P. Dumargue, A direct method for determining chloride diffusion coefficient by using migration
test. Cement and Concrete Research. 34(11) (2004) 1967-1973.
[37] D. Landolt, Corrosion and surface chemistry of metals. CRC Press, 2007.
[38] C.Hsu, F. Mansfeld, Technical note: concerning the conversion of the constant phase element parameter Y0 into a capacitance. Corrosion,
2001. 57(09).
[39] U.Rammelt, G. Reinhard, On the applicability of a constant phase element (CPE) to the estimation of roughness of solid metal electrodes.
Electrochimica Acta. 35(6) 1990 1045-1049.

Potrebbero piacerti anche