Param Default

Description Setting range Note


eters value

F1 Defrost time 1~120 Min 30 Min Duration time during defrost


The interval during two defrosts
F2 Defrost cycle 0~120 Hour 6 Hour
(Auto record every one hour)

1 2
Parame Description Setting range Defau lt Parame Description Setting range Default
ters Note ters value Note
value

0: Cumulative controller work When the measured cabinet


Temperature
Defrost cycle time after power on temperature has an error,
F3 1 F13 calibration of cabinet -10.0℃~+10.0℃ 0.0℃
calculation 1:Cumulative compressor work temperature could be calibrated by
sensor
time after power on this parameter.
Dripping time after
F4 0~120min 3min Time delay after finishing defrost
defrost
Before hot gas defrost, the Hide Menu:

compressor stops for 3minutes then Compressor stop


0:Electric heating defrost
start defrost, to make sure the time in the mode of Compressor stop time during when
F5 Defrost type 1:Hot gas defrost 0 H1 1~60Min 30Min
reliability of the system. After hot “Run/stop in a cabinet sensor fails.
2:wind defrost
gas defrost, compressor starts after proportional time”
2 minutes time delay. Compressor start
If defrost sensor temperature is high time in the mode of Compressor start time during when
H2 0~60Min 15Min
than the set value, defrost stops and “Run/stop in a cabinet sensor fails.
Defrost termination
F6 -40.0℃~+50.0℃ 10℃ defrost is forbidden. proportional time”
temperature
Note: if H8=0, this parameter will be Cabinet temperature
Cabinet temperature lower Note:If H5=1,this parameter item
disabled. H3 upper limit alarm 20.0℃
limit alarm value~85.0℃ will be disabled.
-180~-1: Fan starts ahead of value
compressor 180~1(second) Cabinet temperature
-40.0℃~Cabinet temperature Note:If H5=1,this parameter item
0 : Fan and compressor run H4 lower limit alarm -20.0℃
upper lower limit alarm value will be disabled.
synchronically Valid under Fan Controlled value
c: Fan runs continuously( no Mode(H10=0) 0: Absolute temperature
F7 Fan running mode 0 Over temperature
time delay after dripping) Note : If H10=1or H10=2 , this H5 1:Temp On/Off value ± Over 1
alarm mode
d: Fan runs continuously,stops parameter item is disabled. temperature alarm value
during defrost and dripping 0:No
1 ~ 300 : Fan starts behind H6 Start buzzer alarm 1 Buzzer beeps or not during alarm
1:Yes
compressor1~300 (seconds) Note: If the cabinet temperature
0:Normal cabinet temperature
Initial fan start time Initial fan start time delay after reaches start-defrost-temperature
F8 0~300S 30S Display mode during 1:Display dEF
delay after dripping dripping H7 0 within 15minutes after defrost
defrost and dripping 2: Display start-defrost cabinet
Compress start minimum time interval dripping, it displays real-time cabinet
temperature
Compressor start from its last stop (include the temperature.
F9 0~10Min 0
time delay compressor start time delay for the 0:No
H8 Start evaporator sensor 1
initial power on) 1:Yes
Over temperature After power on, during this time When the measured cabinet temperature has an error,
F1 0 alarm time delay after 0~24.0Hour 2.0Hour range, there is no over temperature Temperature has an error, temperature could be
power on alarm signal -10.0℃~+10.0℃ 0.0℃
H9 calibration of defrost calibrated by this parameter.
Refrigeration mode: sensor Note:
If cabinet temperature is higher than if H8=0,this parameter is disabled.
Over temperature “Temp On value + Over temperature 0:Fan is controlled by
F11 0~50.0℃ 5.0℃
alarm alarm value” or lower than “Temp Off compressor time
value-over temperature alarm 1:Fan is controlled by defrost
Note:if H8=0,this parameter is
value”, it alarms. H10 Fan controlled mode sensor temperature 0
disabled.
Alarm won’t occur until over 2:Fan is controller by the
Over temperature
F1 2 0~120Min 10Min temperature duration is longer than temperature difference between
alarm time delay
this parameter. cabinet sensor and defrost

3 4
between refrigeration and
synchronically,
heating, the timer of “defrost
stop during
cycle” will be cleared and it
defrost and
will start timing again.
dripping.
Defrost control
Compressor control Electric-heating Fan control
Hot gas defrost
defrost
The controller
controls the
The controller controls the
0: The controller controls the start/stop of defrost start/stop of
start/stop of compressor
Refrige device according to the parameter “def cycle” and fan according
according to the parameter “On
ration “def time”. to Fan
Temp” and “Off Temp”
controlled
mode
Heating is realized by controlling the start/stop of
defrost device according to the parameter “heating
start temperature” and “heating stop temperature”.
Note:If heating is realized
by hot gas theory, defrost is
Fan runs
In hot gas defrost, compressor realized by controlling the
1: continuously,
starts; Note: If heating is start/stop of defrost device
Heating stops during
In electric-heating defrost, realized by according to “Defrost cycle”
defrost and
compressor doesn’t work. heater(electric-heatin and “Defrost time”.At this
dripping
g), there is no defrost time, condenser is in the
function. status of defrost, therefore,
“defrost termination
temperature” is invalid.

After refrigeration, if the calculation of “defrost During


cycle” is not finished, and it starts heating, then the refrigeration:
timer of “defrost cycle” and “defrost time” is cleared. the controller
After refrigeration, if there is no heating controls the
proceeded, and it finishes the calculation of “defrost start/stop of
cycle”, then it starts defrost. fan according
to fan
Note:The defrost function takes priority over
Integrated the function of controlled
refrigeration and heating function.
refrigeration and heating, mode.
2: execute the corresponding Note 1: During

Consta refrigeration or heating function refrigeration, if finish

in each phase. “defrost cycle”, then it


nt
begins hot gas defrost on
temper the evaporator.
Note:If heating is During
ature During heating, if
realized by heater heating:Fan
finish “defrost cycle”, then
(electric-heating), and heater
it begins hot gas defrost on
there is no defrost the evaporator. run/stop

function. Note 2:During the switch synchronically,

5 6
EK-3030

10A 10A 10A

1 2 3 4 5 6 7 8 9

L Pb1 Pb2
Power
N 220V

Jiangsu Jingchuang Electronics Co.,Ltd. 0302 1 5