Created by,
Prashant S B
prashant@freyrenergy.com
8150834562
About Freyr Energy
Freyr SunPro is developed by Freyr Energy.Freyr Energy is a Hyderabad based full service distributed
solar solutions provider with operations in India and Ghana.The company's products range from
Rooftop Systems, Petrol Pumps, Solar Water Pumps to Microgrids. In the last two years, Freyr has
installed over 750 solar systems across 10 states in India and impacted over 40,000 lives on rural
India and Ghana. Freyr is a MNRE Chanel partner and a ISO-9001 and a 14001 certified company.
Project Summary
System Overview
Product Classification Off-Grid
System Size (KW) 3.0
Inverter Size (KW) 3KVA, Single Phase
Battery Bank (Ah-V) 180 Ah - 48 V
Net Metering No
Price (INR) 3,88,100
Taxes and Others Taxes as applicable, transportation at actuals
Payment Terms 30% Advance, 60% on Delivery and 10% on installation

Technical Details
The system has been designed for following inputs:

Load Type Load (W) Quantity Day Usage (hrs) Night Usage (hrs)
Tube Light 40 30 6.0 5.0

* Site survey is not completed , the system specifications and price could change based on site survey,which is accurate.
Solar Module Details
Make Trina
Wattage of each module * 300
Number of Modules 10
Warranty 10 yrs workmanship warranty; 25 yrs performance warranty.(90% upto year 10;
80% upto year 25)

* Wattage and number of modules is subject to change, total system size is however unchanged

Inverter Details
Make Neowatt
Rating KW per inverter 3
Quantity 1
Total KW 3
Number of Phases Single Phase
With MPP Tracker Yes
Warranty 5 years warranty

Mounting Structure Details (Fixed Tilt)


Material Type Regular System
Wind Speed Resistance 145 Kmph (standard, can be customised for higher wind speeds)
Warranty 10 year warranty

Battery Details
Make Exide
Battery Bank 180 Ah -48 V
Quantity of Batteries 4.0 batteries of 12V each
Warranty 5 Years Warranty
Battery Type Low maintenance lead acid batteries
Balance Of Systems

Item Description Make Unit Quantity


DC Disconnector (2 pole DC MCB) 5 IN 1 OUT: 63 Amp with box Legrand Each 1

AC Disconnector (2 Pole AC MCB)- 20 Amp with Box Legrand Each 1


Load

AC Disconnector (2 Pole AC MCB)- 25 Amp with Box L&T Each 1


Grid

Reputed 8
DC Lugs1 4 sq.mm Copper Ring Type Each
make

Reputed
DC Lugs2 16 sq.mm Copper Ring Type Each 6
make

Reputed
AC Lugs1 4 sq.mm Copper Each 10
make

Reputed
AC Lugs2 10 sq.mm Copper Each 10
make

DC Cabling Modules to AJB 1C x 4 sq.mm Siechem Mtrs 15

AC Cabling -flexible cable -AC 2C x 4 sq.mm Polycabb Mtrs 15


(Inverter to Load)

AC Cable (Earthing and ligthning 1C x 4 sq.mm Polycabb Mtrs 30


arrestor)

Copper Plate 300mm x 300mm x


3.15mm with 1.5 Meter pole with Reputed
Earthing System Each 2
10kgs of coal and 10kgs of salt per make
pit

Reputed
PVC pipe (outdoor rated) 1 inch Each 7
make

Reputed
PVC L bend (outdoor rated) 1 inch Each 11
make

Reputed
PVC T bend (outdoor rated) 1 inch Each 5
make

Heavy duty flexible corrugated PVC Reputed


1 inch Mtrs 5
pipe (outdoor rated) make

Reputed
MS Clamp for PVC mounting 1 inch Packet 1
make

Reputed
MC4 Connectors Positive and Negative Pair 12
make

Reputed
Cable Ties Size 300 (1 Pac - 100No's) Packet 1
make

Reputed
Screw & Rawal Plug 35 x 8 screw Each 1
make

Reputed Total
Insulation Tapes Red, Black and Green set 3
make Rolls

Cabling - Battery bank 1C x 10 sq.mm Polycabb Mtrs 5

Reputed
Lugs1 10 sq.mm Copper & Ring type Each 12
make

Reputed
Lugs2 10 sq.mm Copper & Pin type Each 3
make
Fasteners for fixing Reputed
M6 x 3 inches Each 22
ACDB,DCDB,Inverter make

Cubic
Civil Works Civil Works Civil Works 6
Feet
Single Line Diagram

5 IN 1 OUT: 63.0 DC Disconnector


Amp with box (2 pole DC MCB)

DC Cable 1C x 4 sq.mm DC Cable 1C x 4 sq.mm

Solar PV
300 Wp X 10 Modules

Inverter :
Neowatt
Single Phase
3 KVA 1 Number

Exide
180 Ah - 48 V
Grid 4 Number
Diesel
generator AC Cable 2C x 4 sq.mm AC Cable 2C x 4 sq.mm
(if
applicable)

AC Disconnector
Consumer distribution box 20 Amp with Box (AC MCB) - Load

Consumer loads
Site Survey

Comments:
Inverter Room Location
Other
Annual Environmental Impact

Number of trees saved CO2 emissions saved


47 4.1 Tons