Installation/Programming Manual
www.hidcorp.com EntryProx Installation/Programming Manual
Copyright 1999 Model Number 4045AGN00, Rev. 1.0
HID, Corp.
For more information, contact:
Telephone:
949-598-1600
800-237-PROX (toll free in U.S.)
949-598-1690 (tech support fax)
Fax: 949-598-1690 (main fax)
Table of Contents
Foreword
F.1 About this Manual................................................ ix
F.2 Safety Warnings and Cautions........................... ix
F.3 Design Change Disclaimer ................................. ix
F.4 Reproduction Disclaimer .................................... ix
F.5 Technical Support ................................................. ix
F.6 Warranty ................................................................ x
F.7 Items Supplied from the Factory....................... xi
F.8 Items the Installer Must Supply ........................ xi
Chapter 1: Description
1.1 General Description............................................. 1-1
1.1.1 Design Function ............................................ 1-1
1.2 Uses and Installation Configurations............... 1-2
1.3 Inputs/Outputs ..................................................... 1-2
1.4 Unit Capacity........................................................ 1-2
1.5 Operating Modes ................................................ 1-3
1.6 Alarm Output Selection...................................... 1-3
1.7 EntryProx Operation........................................... 1-4
Chapter 2: Installation
2.1 Installation Configurations................................. 2-1
2.2 Other Installation Considerations..................... 2-2
2.2.1 Power Supply/Current Requirements ....... 2-2
2.2.2 Gang Box and Mounting ............................. 2-2
2.2.3 Mounting the Unit on Metal....................... 2-3
2.2.4 RF Interference .............................................. 2-3
Chapter 3: Programming
3.1 Programming from the Keypad.........................3-1
3.1.1 Master Code....................................................3-1
3.1.2 EntryProx Default Settings...........................3-2
3.2 Changing the Main Relay Time.........................3-4
3.3 Resetting the Master Code and System
Defaults Only ..............................................................3-4
3.4 Erasing Entire Memory/Resetting System
Defaults.........................................................................3-5
3.5 Turning Audio Keypress Feedback ON/OFF ...3-5
Chapter 4: Troubleshooting
4.1 Before Calling HID...............................................4-1
4.2 Flow Charts ...........................................................4-4
4.3 Performing Power Supply Integrity Test ..........4-7
4.4 Correcting Possible Water Problems..................4-10
A. Silicone............................................................4-10
B. Wire Run.........................................................4-10
Chapter 5: Miscellaneous
Information
5. 1. Customer Service Policy....................................5-1
5.2 RMA Policy ............................................................5-2
Index
List of Tables
F.7 Items Supplied The following items are supplied from the factory with
from the Factory the initial EntryProx shipment.
F.9 FCC Warning This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired op-
eration.
FCC ID Number: JQ64045
1.1 General
Description
The HID EntryProx Proximity Reader/Keypad Door
1.1.1 Design
Function Access Control provides card and/or keypad access
control for a single door. The unit can be installed in
a one-stage configuration (which is typical for most
users) or a higher security, two-stage (or “remote”)
configuration.
In the “secure” (or remote) configuration, the antenna
can be detached and mullion-mounted up to a maxi-
mum of 10 feet away from the controller/keypad. For
installation details, see Chapter 2.
The EntryProx unit is compatible with all HID prox-
imity cards, with up to 37 bits. Batch programming can
be done only with 26-bit HID cards. All programming
is performed using the built-in keypad.
These four specific types of users can be programmed
with the EntryProx unit:
• 0-Toggle/latch strike
• 1-Normal access
• 2-log Dump
• 3-Lockout
For convenience, proximity cards can be programmed
efficiently in a “batch” mode. A user-programmable
ELECTRICAL
Power Supply/Current 10-15 VDC, linear filtered and regulated power supply
Requirements recommended (not including door locking device or
peripherals); 500 mA
WIRING
Remote Antenna Cable ALPHA 1174C (22AWG) 4-wire, stranded, unshielded
(this is required ONLY if you choose to remote the
antenna 10 feet away from the keypad/controller)
Wiegand Interface Cable ALPHA 1295C (22AWG) 5-conductor, stranded, either
overall shield or equivalent (this is required ONLY if
using a separate Wiegand control panel)
Power Supply Cable 18AWG - 22AWG 2-wire stranded, shielded (depends
upon distance)
Door Lock Cable 18AWG - 22AWG 2-wire stranded, unshielded
(depends upon distance)
Door Monitor Cable 18AWG - 22AWG 2-wire stranded, unshielded
(depends upon distance)
REX Cable (if using remote switch) 2-wire stranded, unshielded
MECHANICAL
Height 5.25 in (13.3 cm)
Width 2.75 in (7 cm)
Depth 1.375 in (3.5 cm)
RELAY OUTPUTS
Main Relay - Form C (switches up to 4A)
Aux Relay - Form C (switches up to 1A)
MONITOR INPUTS
Door Position (Normally Closed, dry contact)
Request to Exit (REX, Normally Open, dry contact)
OTHER OUTPUTS
Infrared output to optional IR printer
Wiegand output to separate control panel
SOUNDER 4000 Hz, defeatable
LEDs
Bi-Color (red/green)
Amber
COMPATIBLE
PROXIMITY CARDS
All HID cards up to 37 bits, including the following:
Prox Card II
IsoProx II
Duo Prox II
Proxkey FOB
UNIT CAPACITY
Users 2,000 users maximum; each user can have a
card/tag, a PIN code, or a card/tag PLUS a PIN code
Transactions 1,000 transactions maximum; each transaction
includes time, date, user “slot number,” and event
Strike Time 1-99 seconds
Strike Mode Access Time or Toggle/Latch
ALARM OUTPUT
One of three functions can be wired: Alarm Shunt
Relay, Forced Door Relay, or Propped Door Relay
2.2.3 Mounting the The EntryProx unit uses radio frequency to transfer
Unit on Metal power to and communicate with the proximity card
or keytag. If the antenna is mounted directly on a metal
building or wall, some of the energy is absorbed by
the metal, resulting in less power being transmitted to
the keytag; this causes reduced read range. If you must
mount the EntryProx unit on metal, test the unit in
place before permanently installing it. If read range
distance distance is not adequate, a non-metallic spacer
can be fabricated and installed between the unit’s an-
tenna and the metal mounting surface.
The EntryProx unit should not cause interference to
2.2.4 RF Interference
other equipment as it is designed to meet FCC guide-
lines. However, other devices can interfere with En-
tryProx operation.
Avoid locating the EntryProx unit closer than 3 feet (1
meter) to a computer monitor or television or another
EntryProx unit. If you believe you are experiencing
reduced read range due to interference, try reposition-
ing the EntryProx unit, remoting the antenna, or relo-
cating other nearby electrical equipment.
WIEGAND OPERATION
BLUE
BROWN
+V WHITE
GND GREEN
P1 P3 P2
P4
2.3 Checking the Figure 2-2 below provides a detailed illustration of the
Cables EntryProx’s wiring harness. Figure 2-3 illustrates the
Pin connectors on the main circuit board; Table 2-1
describes these four Pin connectors, P1, P2, P3, and P4.
WIRING HARNESS/
CABLE CROSS-SECTION 1-GREEN
2-GRAY
3-BLUE
4-BROWN
5-ORANGE P2
P1 6-WHITE
1-GRAY
2-GREEN
3-BLUE
4-BLACK
5-RED
P1 P3 P2
P4
3
WIRING
EXITS SINGLE
GANG BOX
HOLES
CONTROLLER
BACKPLATE
4
PRESSURE-
SENSITIVE
PADS ON THE
2 BACKSIDE OF
SIDE BACKPLATE
CUT-OUTS
MAX. 10 FEET
FROM KEYPAD/ 4 EXTERNAL
CONTROLLER CUT-OUTS
2 WIRING (MATCH SPRING-
EXITS LOADED TABS)
ANTENNA
REMOVE ANTENNA FROM BACKPLATE
KEYPAD/CONTROLLER BY 4 SPRING-
PRESSING FOUR SECURE LOADED TABS
TABS INWARD UNTIL
ANTENNA POPS OUT 2 SCREW
HOLES
PROX
SENSOR
2 OPTIONAL HOUSING
SIDE BREAK-OUTS
2 WEEP HOLES
REVERSE
VIEW OF
FILLER
PIECE
DOGBONE
FILLER PIECE/
REX OPERATION
2 TABS
REMOVED
FOR REX
OPERATION
FILLER
PIECE
DECIDE BETWEEN
REPLACING WITH "PRESS TO EXIT"
FILLER PIECE AND LABEL (APPLIED
REX OPERATION AFTER INSTALLATION)
IF USED AS A REX
BUTTON
2.5 Wiring the Select one of these three wiring options, Alarm Shunt,
EntryProx Unit Forced Door, or Propped Door, depending on how the
EntryProx’s alarm output is to be employed for this
installation. Then refer to sections 2.5.1 - 2.5.3 as ap-
propriate.
The Alarm Shunt Relay function may be necessary
2.5.1 Wiring the AUX
Relay for Use as when a separate existing security system is in place.
Alarm Shunt The Alarm Shunt Relay keeps an alarm panel zone
from going into alarm when the door is opened, after
a valid code is entered. No programming is required
for a new unit out-of-box, or if the unit is ever defaulted
using programming commands 40# and 46#. The En-
tryProx controller assigns the AUX relay to the Alarm
Shunt Relay automatically upon any valid access or
egress. To incorporate this feature, follow the steps
below; see Figure 2-7.
Wiring the Alarm Shunt Relay
1. Turn OFF power to the EntryProx unit, and then
unlatch the keypad from the plastic housing.
2. Locate connector P2 (the 6-pin connector) on the
main circuit board and plug on the 6-pin harness.
(The 2-pin jumper on pins 5 and 6 of connector
P2 must be removed first.)
3. Connect the 6-conductor harness to connector P2
as shown in Figure 2-7.
4. Connect the green wire to the “Common” side of
the door contact.
5. Connect the blue wire to the “Normally Open”
side of the door contact.
6. Make a parallel connection to the green and blue
wires and run the leads to the alarm panel. NOTE:
This feature requires that you use the “Door Con-
tact” input as shown in Figure 2-7.
TO ALARM PANEL
DOOR
CONTACT
GOING BACK
TO ALARM
PANEL BLUE (C)
GREEN
(N/O)
SEPARATE DOOR
P1 P3 P2 CONTACT BEING
MONITORED BY
PROX PAD
WHITE
P4
2.5.2 Wiring the AUX The Forced Door output function informs personnel
Relay for Use as that the door has been opened without authorization.
Forced Door The Aux relay is rated to handle one amp of current
at 12 VDC, and can turn ON or OFF one leg of the
power to a warning device. (Warning device not in-
cluded with the HID unit.) To incorporate this feature,
follow the steps below; see Figure 2-8.
Wiring the Forced Door Relay
1. Turn OFF power to the EntryProx unit, and then
unlatch the keypad from the plastic housing.
2. Locate connector P2 (the 6-pin connector) on the
main circuit board.
3. Connect the 6-conductor harness to connector P2.
(The 2-pin jumper on pins 5 and 6 of connector
P2 must be removed first.)
4. Connect the green wire to V+ on the warning
device.
5. Connect the blue wire to V+ on the power supply.
6. Connect V- from the power supply to V- on the
sounder. The gray wire is not used.
TO POWER SUPPLY
V- V+
-
+
V+
GREEN BLUE
(NO) (C)
P1 P3 P2
P4
2.5.3 Wiring the AUX The Propped Door Relay output function informs per-
Relay for Use as sonnel that the door is being held open, or “propped”
Propped Door open, after a valid entry. The Aux relay is rated to
handle one amp of current at 12 VDC, and turns ON
or OFF one leg of the power to a warning device.
(Warning device not included with the HID unit.) To
incorporate this feature, follow the steps below; see
Figure 2-9.
Wiring the Propped Door Relay
1. Turn OFF power to the EntryProx unit, and then
unlatch the keypad from the plastic housing.
2. Locate connector P2 (the 6-pin connector) on the
main circuit board.
3. Connect the 6-conductor harness to connector P2.
(The 2-pin jumper on pins 5 and 6 of connector
P2 must be removed first.)
4. Connect the green wire to V+ on the sounder.
5. Connect the blue wire to V+ on the power supply.
6. Connect V- from the power supply to V- on the
sounder. The gray wire is not used.
TO POWER SUPPLY
V- V+
-
+
V+
GREEN BLUE
(NO) (C)
P1 P3 P2
P4
2.5.4 Wiring the Door To solve the problem of people “tailgating” in behind
Contact Input personnel using valid access protocol, the Auto Re-
Lock feature is provided. With Auto Re-Lock, a long
door open time can be programmed. Auto Re-Lock
overrides the main relay timer, resetting the door open
time as soon as the EntryProx unit senses that the door
is open. A long door open time allows people sufficient
time to carry packages from the proximity reader/key-
pad to the door and open it before the timer runs out.
No programming is required to implement this fea-
ture.
After a valid access or egress, the EntryProx unit senses
that the door switch is open and drops the main relay
immediately. This disengages the lock, which locks
behind the person regardless of how long it takes that
person to get through the door.
DOOR CONTACT
ORANGE
DOOR
CONTACT
WHITE
P1 P3 P2
P4
2.5.5 Wiring the REX The EntryProx unit can be wired to monitor a remote
Switch switching device, which is intended to be installed on
the “safe” side of a door. The Request to Exit (REX)
switch is a momentary input that engages the main
relay for the same length of time for which the main
relay is programmed. This feature can be stored in the
Transaction Log for viewing.
If you elect to perform a secure installation where the
controller is mounted on the secure side of the door,
you can use the filler piece as a REX switch, thereby
decreasing the cost of the installation. For other instal-
lations, a separate REX switch must be purchased.
Other REX devices include a remote button placed at
a receptionist’s desk, a press-to-exit switch on the in-
side of a door, or a passive infrared detector, allowing
free and convenient egress. The REX feature requires
no programming; simply wire the unit as illustrated
in Figure 2-11. To incorporate this feature, follow the
steps below:
1. Turn OFF power to the EntryProx unit, and then
unlatch the keypad from the plastic housing.
2. Locate connector P2 on the main circuit board.
3. Plug the 6-conductor harness into connector P2.
(The 2-pin jumper on pins 5 and 6 of connector
P2 must be removed first.)
4. If you do not wish to install the door contacts per
Figure 2-11, twist the white wire and the orange
wires together; this is mandatory. If this is not
done, the REX input will not function.
ORANGE ORANGE
NORMALLY
BROWN OPEN BROWN
SWITCH
P1 P3 P2 WHITE P1 P3 P2 WHITE
NORMALLY
OPEN
SWITCH
DOOR
CONTACT
P4 P4
2.5.6 Wiring the Main The door lock is wired to connector P1 on the En-
Relay tryProx main circuit board. Wiring for this 5-pin con-
nector is described in Table 2-1, Figure 2-12 provides
an Electric Strike (Fail Secure) wiring diagram, Figure
2-13 a MagLock (Fail Safe) wiring diagram. Refer to
the power supply recommendations in section 2.2.1 if
necessary.
LOCK WIRING DIAGRAM
STRIKE
(FAIL-SECURE)
V-
POWER
V+ SUPPLY
BLACK
(V- ) BLUE
(MAIN RELAY C)
GREEN
(MAIN RELAY N/O) RED
(V+ IN)
P1 P3 P2
P4
MAGLOCK
(FAIL SAFE)
V-
POWER
V+ SUPPLY
BLACK
(V- ) BLUE
(MAIN RELAY C)
GRAY
(MAIN RELAY N/C) RED
(V+ IN)
P1 P3 P2
P4
FRONT
HOUSING
ASSEMBLY
PUSH TABS IN
DIRECTION OF
ARROWS TO REMOVE
REVERSE
TO RE-INSERT
3.2 Changing the Setting the main relay time for the master code simul-
Main Relay Time taneously sets the time for users in register one through
register two-thousand. The factory default main relay
time is five (5) seconds. Main relay time can be set in
one-second increments from one (1) second to ninety
(99) seconds using command 11.
1. Place the EntryProx unit in program mode. Press:
99 # Master Code * (default is 1234)
A slow blinking yellow LED indicates that the unit
is in program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.
2. Enter the new main relay time, in seconds (from
1 to 99). For example, to enter 10 seconds, press:
11 # 10 # 0 # **
The yellow LED continues to blink slowly.
3. Press * to exit program mode.
3.7 Adding New or The most basic EntryProx programming is adding new
Changing Existing codes or cards (users), or modifying existing codes or
cards (users). Each user entry consists of three or four
Codes/Cards data values: a user type, a location and a keypad-PIN,
and/or card.
Two methods can be used for adding new or changing
existing codes/cards, (1) keypress sequences (manual
entry), and (2) card presentations. Keypad PINs can
be programmed only through a keypad sequence,
while card PINs can be programmed manually or by
presenting the card to the proximity reader at a speci-
fied time during programming. These four specific
types of users can be programmed with the EntryProx
unit:
• Toggle/latch strike (0)
• Normal access (1)
• log Dump (2)
• Lockout (3)
3.8 Adding Cards “Batch entry” allows you to enter multiple, sequential
26-bit HID cards into the EntryProx unit’s memory at
via Batch Entry one time. (Keeping HID proximity cards in order is
easy as the code is printed on the front of each card.)
3.9.5 Programming The format for programming a user for both Code
Code AND Card Use AND Card use is as follows:
50 # user-type # user location # keypad PIN
* keypad PIN * <present card>
Card ONLY use can be programmed with command
3.9.6 Programming
Card ONLY Use 50, with the keypad PIN values omitted from the se-
quence. For instance, to program user 200 as a “Nor-
mal” access user with Card ONLY, press:
50 # user-type # user location # **
<present card>
Finally, you can program a user for either Code OR
3.9.7 Programming
Code OR Card Card use as follows:
3.11 Programming Table 3-3 identifies and describes the four user types
User Types supported by the EntryProx unit. NOTE: All examples
show programming the four user types as card only
users. All four user types can also be programmed as
code only, code and card, and code or card.
PCB
MASTER
CODE
SWITCH
(PROGRAM
SWITCH)
(ON REAR SIDE
OF PC BOARD)
CONTROLLER
HOUSING
1. Change master
code
Code-only 1 # (new code) * (repeat code) *
operation
(example, 4321 1 # 4321 * 4321 *
master code)
0=disabled,
3. Set AUX relay 1=shunt,
15 # output # 0 # **
output 2=forced door,
3=propped door
5. Print a
70 # 0 # 0 # **
transaction log
6. Set/clear
30 # option # s/c # ** see below
standard option
Option Set/Clear
0, audio keypress feature 0=OFF, 1=ON
1, visual keypress feature 0=OFF, 1=ON
2, auto entry enable 0=OFF, 1-ON
3, standalone/wiegand 0=standalone
operation 1=wiegand
4, facility code access 0=OFF, 1=ON
5, forced door audio alert 0=OFF, 1=ON
6, propped door audio alert 0=OFF, 1=ON
Option Set/Clear
7, internal rex switch 0=OFF, 1=ON
8, US/EU date format 0=US,
1=European
9, wiegand red LED enable 0=OFF, 1=ON
10, wiegand red led active 0=LOW,
state 1=HIGH
11, wiegand green led 0=OFF, 1=ON
enable
12, wiegand green led 0=LOW,
active 1=HIGH
13, daylight savings time 0=OFF, 1=ON
7a. Print
25 # 0 # 0 # ** see section 3.13.4
programmed user list
7b. Print
programmed user
25 # 0 # start user # **
list (starting at a
certain user)
8. Change Wiegand
32 # parameter # value # ** see below
parameters
Parameter Value
0, wiegand pulse count 1-255
(8-160µs)
1, wiegand interpulse 1-255
(spacing
32-640µs)
2, facility code 0-255
(defaults to 0)
hhmm=hour/minute,
9. Set system time 41 # hhmm # 0 # **
24-hr format
mmddyy=month,
10. Set system date 42 # mmddyy # dow # ** date, year; dow=day
of week, 1=Sunday
ttt=propped door
13. Set forced door
time, to nearest 10’s
time (this sets time
45 # ttt # 0 # ** seconds, entered as
for both Aux Relay
10-990;
and local sounder
default=10 secs
23. Reset/erase
76 # 00000 # 00000 # ** see section 3.13.3
transaction log
NO
YES
PASS FAIL
PASS
Persistent?
Revert to above
1. Set meter to read continuity, step.
1. Reprogram EntryProx
remove power from Main relay and re-test. 2. See "Note" at
common of EntryProx. 2. Enter bottom of page.
code 1234* to verify that relay
activates.
Troubleshoot per
instructions in Table 4-1.
PASS
FAIL
Bad EntryProx
The EntryProx is working
Meter voltage at lock and
properly, the problem may
enter 1234* .
reside with the locking device.
NO
Meter show
Change not occurring
change?
YES
Bad lock
NO
FAIL
PASS
PASS
NOTE: A glitch in the keypad program might result from using a power
supply that is not filtered and regulated properly. For extra filtering
suggestions, call HID technical support.
NO
PASS
FAIL
1. Verify that door position switch closed before
Troubleshoot per instructions attempting to engage the REX. (EntryProx ignores
in Table 4-1. this input when door is open.) 2. If no door PASS
contacts are used, jumper input together with a
piece of wire and try again.
YES
FAIL
1. Verify that no other equipment is monitoring 1. Verify that exit device is "dry contact"
same door contacts as EntryProx. 2. If so, and no induced voltages, A/C or D/C, are
disconnect all other devices on that set of being applied to input. 2. More than one
contacts, except the EntryProx. 3. Try again. volt?
YES
NO
If problem persists, Locate source and
see Note at bottom. eliminate. (Circuit requires
a dry switch.)
4.3 Performing This test confirms whether or not the power source is
Power Supply providing sufficient amperage to support all the equip-
ment. It indicates whether or not a stable electrical
Integrity Test
environment exists by revealing fluctuating voltages
during operations. A fluctuation in voltage exists when
the equipment draws more amperage than the power
supply offers.
As the EntryProx unit cycles the equipment ON and
OFF, power must remain constant. If a voltage fluctua-
tion of one-quarter volt or more occurs during testing,
in either the positive or negative direction, the test
results indicates a “fail” response. If the voltage retains
proper amplitude (remains constant), the test indicates
a “pass” response.
1. Set the meter to read voltage and place meter
probes on the red and black wires of P1, located
on the EntryProx unit. You may have to reference
Figure 2-3 for details. If the EntryProx unit consists
of two parts, a reader and a controller, the termi-
nals are located on the controller.
The voltage reading is monitored throughout the
entire test.
2. With power being applied to the entire EntryProx
unit, enter a valid code on the EntryProx keypad.
The REX input can be used in place of a valid
code; the test results remain the same. Reference
the keypad circuits diagram for REX input, located
in Chapter 2 of this manual.
3. Observe the meter as the keypad cycles the system
ON and OFF. The voltage should remain constant
during this operation, indicating that the electrical
system is stable and adequate.
1. Acquire an alternative power supply that matches Check circuit breaker, or obtain assistance of a
unit voltage, battery preferred. 2. Disconnect licensed electrician.
EntryProx power by removing wires from the (+) and FAIL
(-) wires at EntryProx. 3. Connect alternative power
to EntryProx and re-test per section 4.2.
Resolve and re-test per instructions in
section 4.3.
PASS
Ensure power supply donates ample power by 1. Disconnect all accessories and lock from
adding the max. current draw of each device. EntryProx. 2. Re-connect original power
FAIL
(Total AMPs should be less than provided by supply. 3. Re-test per instructions in section
power supply.) 4.3.
FAIL
Bad
PASS
PASS
EntryProx
A larger power
supply is required.
If applicable, ensure the lock's power selection
jumper is selecting proper voltage setting. (In
Problem is prior to
wrong position, current draw doubles.)
the EntryProx.
NOTE: A glitch in the EntryProx program might result from using a power
supply that is not filtered and regulated properly. For extra filtering
suggestions, call HID technical support.
U
Unit Capacity, 1-2
Users Chart, A-1
Uses and Installation Configurations,
1-2
Using the Printing Features, 3-15 -
3-20
W
Wall Mounted Installation, 2-1
Warranty, x
Wiegand Mode, 1-3
Wiegand Operation, 2-4
Wire Run, 4-10
Wiring AUX Relay for Use as Alarm
Shunt, 2-18
Wiring the AUX Relay for Use as
Forced Door, 2-20
Wiring the AUX Relay for Use as
Propped Door, 2-22
Wiring the Door Contact Input, 2-24
Wiring the Main Relay, 2-28
Wiring the EntryProx Unit, 2-18 - 2-30
Wiring the REX Switch, 2-26