Sei sulla pagina 1di 40

Smart choice for power™

Xantrex™
Renewable Energy
and Backup Power
Catalog
Inverters
Inverter/Chargers
System Components
Battery Chargers
Powerpacks

www.xantrex.com
Renewable Energy & Backup Power Catalog

Contents
Glossary 2-3
System Basics 4-5
Solar Inverters
GT Series 6
GT30E 8
GT100E 10, 11
GT250E 10, 12
GT500E 10, 13
Inverter/Chargers
XW Hybrid Inverter/Charger 14
Trace Inverter/Chargers 16
Inverters
Prosine 18
About Xantrex™
XPower Inverters 20
Xantrex Technology Inc. is a world leader Xantrex products convert and control Battery Chargers
in the development, manufacturing and raw electrical power from any central, XC Battery Chargers 22
marketing of advanced power electronic distributed, renewable, or backup power Powerpacks
XPower PP 175 Plus 24
products and systems. Xantrex makes a source into high-quality power required
XPower PP 300/300 Plus 26
positive difference in the lives of people by electronic and electrical equipment.
XPower PP 400 Plus 28
around the world by combining proven Xantrex products meet the needs of a Charge Controller
technology with unparalleled market wide range of customers as stand-alone XW Charge Controller 30
understanding to bring electricity to power products, as key components C Series Charge Controller 32
customers anytime, anywhere. integrated into equipment produced C12 Charge Controller 34
by others, or combined with a power Accessories
Xantrex operates in the higher growth source to provide self-contained power Gateway 36
and higher value segments of the solutions. Xantrex products are smaller,
advanced power electronics market. Its lighter, smarter, more efficient and
well-established products are sold to more reliable than traditional power
a diverse customer base in renewable, conversion equipment.
programmable, mobile, and portable
power markets.
What is an inverter?
Modern inverters have caused a quiet revolution in the way we live with indepen-
dent power systems, providing silent AC electricity anytime, anywhere. An inverter
is a sophisticated microprocessor controlled device that transforms the DC power
collected from your renewable energy source into household (AC) electricity. An
inverter that is connected to the grid allows you to sell the excess renewable power
you harvest to the utility company.

What is an inverter/charger?
An inverter/charger combines an inverter, battery charger, and transfer switch in
one box. In addition to converting DC power from the renewable energy source into
AC power, an inverter/charger can also convert AC power from a generator into DC
power to recharge batteries. To ensure the power supply is uninterrupted, some
models feature automated generator start and stop capabilities, so supplementary
power is automatically produced as necessary. The inverter/charger’s ability to
process multiple forms of incoming power makes it a popular choice for off-grid
applications as it provides homes with a completely autonomous supply
of electricity.

Wave Forms Explained


Today’s inverters, which simulate utility power electronically, produce two types of
AC power: modified sine wave or sine wave. The differences between these types of
inverters are subtle, but significant in the way they operate certain types of loads.

Sine Wave
Modified Sine Wave Inverters
Modified sine wave inverters can adequately power most household appliances Modified Sine Wave
and power tools. These inverters are less expensive. However, this waveform may
present certain compromises with some loads such as microwave ovens, laser
printers, clocks, and cordless tool chargers.

Sine Wave Inverters


Sine wave inverters are the most sophisticated inverters on the market today.
They are designed to replicate and even improve on the quality of electricity
supplied by utility companies.

1
Glossary of Terms

Alternating Current (AC) Electrolyte


The type of electricity supplied by A conductive medium in which the flow
the utility company. The unique of electricity takes place; this is the liquid
characteristic of this form of electricity found inside storage batteries.
is that it reverses direction at regular
Grid
intervals. For example, 230 Vac 50 Hz
When used in reference to utility
power reverses flow 50 times a second,
power, it refers to a system of electrical
hence the rating 50 Hz (cycles).
transmission and distribution lines.
Amp (A)
Ground Fault Protection (GFP) Inrush Current
A measurement of the flow of
A circuit protection device that prevents The peak power an appliance or tool will
electrical current.
the flow of electrical current to earth if a draw at the instant it starts up.
Amp Hour (Ah) short circuit is present. Usually required
Kilowatt (kW)
One amp of electrical current in wet locations, e.g. for outdoor, kitchen,
One thousand watts of electricity. Ten
flowing for one hour. Expresses the and bathroom circuits.
100-watt light bulbs use one kW of
relationship between current (amps)
Hertz (Hz) electrical power.
and time. (OHMS law : A =V/R)
The frequency, or number of times per
Kilowatt hour (kW/h)
Array second, that the flow of AC electricity
One kW of electrical power used for one
A group of solar electric modules reverses itself. Also referred to as cycles
hour. Most grid connected electrical
wired together. (see alternating current).
meters measure kWh for billing
Current High Battery Voltage Protection purposes.
The rate of flow of electrical charge. A control circuit that disconnects charge
Line Loss
The flow of amps is often expressed as current flowing to the battery when
A voltage drop caused by resistance in
current. voltage reaches a dangerously high
wire during transmission of electrical
threshold. Prevents damage created by
Direct Current (DC) power over distance.
excess gassing (or boiling) of electrolyte.
The type of electricity stored in
Load
batteries and generated by solar Idle Current
Any device that consumes electricity to
electric devices. Current flows in a The amount of electrical power required
operate. Appliances, tools, and lights are
single direction. to keep an inverter ready to produce
examples of electrical loads.
electricity on demand.


Glossary of Terms

Low Battery Protection Sine Wave


A control circuit that stops the flow of The type of waveform produced by the
electricity from batteries to loads when utility or a generator. Sensitive electrical
battery voltage drops to dangerously low equipment requires sine wave power to
levels. run.

Modified Sine Wave Series Wiring


Also called a modified square wave, this Batteries or PV modules wired together to
type of waveform emulates a sine wave increase voltage, while ampacity remains
using a series of small steps to create constant. Two 100 Ah 12 Vdc batteries
a curve. wired in series form a 100 Ah 24 Vdc Watt(s) (W)
battery bank. A unit of measurement of the amount of
Off Grid electrical power required or consumed by
An electrical system that is not connected Surge Capacity a tool or appliance. Watts = volts x amps
The amount of current an inverter can
to a utility distribution grid.
deliver for short periods of time. Most Watt Hour (Wh)
Overload/Overcurrent Protection electric motors draw up to three times Electrical energy consumption or capacity
A control circuit designed to protect an their rated current when starting. An measured in terms of time. One watt hour
inverter or similar device from loads inverter will surge to meet these motor- of electricity is equal to one watt of power
exceeding its output capacity. (A fuse, starting requirements. being consumed for one hour.
for example, is an overcurrent Transfer Switch
protection device.) A switch designed to transfer electricity
Parallel Wiring being supplied to loads from one source of
Batteries or PV modules, wired together to power to another.
increase ampacity, while voltage remains Volts (V)
constant. Two 100 Ah 12 Vdc batteries A unit of measure of the pressure in an
wired in parallel will form a 200 Ah 12 Vdc electrical circuit. If compared to water
battery bank. pressure, a high pressure hose would be
Photovoltaic (PV) Array considered high voltage, while a slow-
Commonly referred to as solar panels, the moving stream could be compared to low
PV array collects energy from the sun and voltage.
converts it into DC energy.


System Basics System Overview

Off-grid system with battery and generator backup

Basic Off-Grid System


With a Xantrex off-grid system, you can easily produce your own power without
the expense and environmental impact of extending power lines, or relying
completely on a generator.

A basic off-grid system consists of a renewable energy source, which generates


DC power, a battery bank that stores the DC power, and a Xantrex inverter.
Our inverter is the intelligent center of a renewable power system, seamlessly
converting DC power to clean, reliable AC electricity for your needs.

The system illustrated here is a solar electric hybrid system that offers additional
automatic features. It consists of a solar array, a battery bank, our top-of-the-line
Xantrex XW Inverter/Charger, a charge controller that manages battery charging
from the solar array, and a generator. When the sun is up, the solar panels
generate power to charge batteries and provide electricity. At night, the Xantrex
inverter/charger automatically runs your electrical equipment from your battery
bank. The generator provides additional back-up battery charging capability
for extended periods of cloudy weather. The Xantrex inverter/charger can
automatically start the generator and initiate a recharge cycle when the battery
bank is depleted or a load is too large for the batteries to support independently.

Xantrex manufactures a complete range of power products to suit various


budgets and electricity requirements. From complete power systems that come
ready to install from our factory, to components that can be integrated into a
system by a Xantrex Dealer, we have a system to meet your needs.


Grid tie system using GT Series Inverter

Basic Grid Tie System


A basic grid tie system consists of solar cells and a Xantrex grid-tie inverter. Solar
cells take the sun’s energy and turn it into DC electricity. The Xantrex inverter
turns the DC electricity generated by the solar cells into utility grade AC power
which can be sold to the utility grid. A grid tie system is an effective way to
obtain economical benefits, increase green energy production and improve
the environment.

Large-scale solar electrical systems play an important part in conservation and


energy production, and Xantrex is a premier supplier of inverters that turn the
Sun’s energy into clean, reliable electricity. Xantrex grid tie inverters are
a leading choice for large-scale solar installations in Europe.


GT Series Grid Tie Inverters (Single phase)

Xantrex new inverters make installation easier and more affordable

When Xantrex set out to develop the High Performance String Full Featured Inverter Display
Grid Tie Solar Inverters we listened to Inverters and Communications
the experts – renewable energy
From 2,5 kW to 5,0 kW Liquid Crystal Display (LCD)
dealers and installers. The result is
Superior PV energy harvest LCD vibration sensor allows the tap
high performance inverters that make
Peak inverter efficiency of a finger to turn backlight on and
utility interactive installations easier
Excellent thermal performance display screen cycling
and more cost effective. Our high
Bright LED indicators provide
performance PV string inverters offer
high efficiency, lower installed cost, Easy and Affordable to Install system status at a glance
PC software for remote monitoring
improved aesthetics and high Wide PV input MPPT tracking
reliability. The GT Series inverters are and system troubleshooting
voltage range makes module
high quality products that offer the selection and sizing extremely
best price/performance ratio in flexible
the industry. Includes a lightweight and versatile
mounting bracket that simplifies
installation
Modular design allows inverters
to be mounted side-by-side
Lightweight and compact size
Rugged IP54 inverter enclosure
allows reliable outdoor and
indoor installations


Solar Inverters

Electrical Specifications
GT2.5DE GT3.8DE GT2.8SP GT3.8SP GT5.0SP
Maximum AC power output 2500 W 3800 W 2800 W 3800 W 5000 W
Nominal AC power output 2300 W 3500 W 2500 W 3300 W 5000 W
DC input voltage range 195 to 600 Vdc 195 to 600 Vdc 195 to 600 Vdc 195 to 600 Vdc 240 to 600 Vdc
Peak power tracking voltage range 195 to 550 Vdc 195 to 550 Vdc 195 to 550 Vdc 195 to 550 Vdc 240 to 550 Vdc
Current THD < 3% < 3% < 3% < 3% < 3%
Peak inverter efficiency 95% 95,3% 95% 95,3% 96%
(includes transformer) (includes transformer) (includes transformer) (includes transformer) (includes transformer)
Euro efficiency 94% 94,5% 94% 94,5% 95,2%
(includes transformer) (includes transformer) (includes transformer) (includes transformer) (includes transformer)
Maximum continuous output current 12,5 Aac 19 Aac 14,5 Aac 19 Aac 23 Aac
Over current protection 15 A 20 A 20 A 20 A 30 A
Night time tare loss 1W 1 W 1W 1 W <1 W

Mechanical Specifications
Operating temperature range -25ºC to 65ºC -25ºC to 65ºC -25ºC to 65ºC -25ºC to 65ºC -25ºC to 65ºC
Enclosure type IP54 IP54 IP54 IP54 IP54
Unit weight 20 kg 20,5 kg 19,5 kg 20 kg 22,3 kg
Shipping weight 26 kg 26,5 kg 25,5 kg 26 kg 27,2 kg
Inverter dimensions (H x W x L) 59,7 x 40,3 x 13,6 cm 59,7 x 40,3 x 13,6 cm 59,7 x 40,3 x 13,6 cm 59,7 x 40,3 x 13,6 cm 59,7 x 40,3 x 13,6 cm
Mounting Wall mount (mounting bracket included)

Features & Options


Cooling Convection (no fan required)
Display Backlit, two-line, Liquid Crystal Display
Communications RS 232 and 2 Xanbus RJ45 ports

Regulatory Approvals
CE marked according to the following EU directives and standards:
EMC Directive EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-3, EN61000-6-1:2001, EN61000-6-3/A11:2004
Low Voltage Directive EN50178:1997 and EN60529/A1:2000
Other approvals Royal Decree RD 661-2007, RD 1663/2000, BGFE Certified to VDE0126

Note: Specifications subject to change without notice


GT30E Grid Tie Solar Inverter (Three phase)

The new compact three-phase solar inverter

More than 250.000 customers around High-efficiency isolated Lightweight


the world rely on Xantrex inverters HF design Lowest weight in its class at 80 kg
and system components to bring
One of the highest efficiencies Easy wall mounting
them electricity every day. During
in the 30 kW class Simplified operation and
the past decade our technology has
Reliable, safe electrical isolation transportation
generated more than 3000 megawatts
Rapid Maximum Power Installation in any location
of power conversion capacity.
Point Tracking
The new three-phase Xantrex GT30E Compact design
Grid Tie Solar Inverter is a 30 kW Designed to maximize Smallest enclosure size in its class
high-performance inverter that makes the return on investment Space-saving installation
utility-interactive installations easier Superior PV energy harvest Multiple inverters are easily
and more cost effective. It offers Simplified, fast installation paralleled for large PV power plants
superior PV energy harvest, easy Excellent thermal performance
installation, high reliability and a Local service network,
compact, ultra-lightweight design. reliable customer service
Engineered for compatibility
with thin-film technology Telephone hotline
Wide input voltage range Installation, commissioning
Isolated high-frequency design and product training
Flexible array sizing and
module selection


Solar Inverters

Electrical Specifications
Nominal power rating (AC) 29,9 kW
Nominal AC voltage 400 V, 3-phase
Nominal AC frequency 50 to 60 Hz
Line power factor > 0,99 above 20% rated power
AC current distortion < 4% THD at rated power
Nominal power (DC) 71 Adc
Night consumption 1W
Min DC voltage for feed-in 450 Vdc
Suggested PV power 25 to 35 kWp
Nominal power rating (DC) 31,9 kW
Max open-circuit voltage 840 Vdc
Power tracking window range 450 to 800 Vdc
Max efficiency 95% incl. transformer
European efficiency 94,2% incl. transformer

General Specifications
Ambient temperature range - 0ºC to 50ºC
Enclosure environmental rating IP20 (optional IP21)
Enclosure Powder-coated aluminum
Weight 80 kg
Dimensions (H x W x D) 71 x 47,5 x 34,7 cm
Relative humidity 0 to 95%, non-condensing

Features & Options


Cooling method Temperature-dependent forced-convection cooling
Protective functions AC over/under voltage, AC over/under frequency, over-temperature, AC and DC over-current,
DC over-voltage and reverse-polarity protection
User-display standard LCD, four-line text display with keypad
Ground-fault protection DC isolation monitoring
Disconnects AC contactor integral to inverter assembly
Transformer HF - Transformer
Installation / Mounting Prepared for wall mounting
Output relays Four relay contacts (three user-settable)
Interfaces RS232/485, optional telephone modem for remote system monitoring
Combiner boxes Optional feature − includes DC over-voltage protection and disconnect, calibrated AC power metering,
string fusing and monitoring, Weblog Pro and irradiance meter
Warranty Five years (extended warranties optional)

Regulatory Approvals
Labeled with CE mark and complies with applicable European Directives:
EMC Directive EN50081-2, EN50082-2
Low Voltage Directive EN50178; complies with the requirements of VDEW
The GT30E complies with the requirements of the Royal Decree, Spain
Note: Specifications subject to change without notice


GT Inverters: GT100E/GT250E/GT500E (Three phase)

From 100 kW to 500 kW three-phase power conversion center

GT100E GT250E GT500E

GT100E/GT250E/GT500E Features Options


The Xantrex Grid Tie Inverters are Digital Signal Processor (DSP) based Remote monitoring via
based on a reliable platform that is controls with self-diagnostics and telephone modem
used in grid-connected photovoltaic LCD for display of operating status Faults notification via modem
and wind turbine applications in Inverter shut off and disconnects Data acquisitions and logging
North America and Europe. Over- and under-voltage and
frequency protection shuts
Designed to be easy to install and down the inverter
operate, the GT three-phase invert- Anti-islanding protection prevents
ers automate start-up, shutdown, back-feeding inverter-generated
and fault detection. They incorporate power to the grid in the event of
advanced Maximum Power Point a utility outage
Tracking Technology to maximize the User definable power tracking
energy harvested from a PV array. To matches the inverter to the array,
minimize power losses during the as well as adjusts delay periods to
conversion process, the inverters’ customize system shutdown
switching technology uses insulated sequences
gate bi-polar transistors. The GT three- Graphical user interface software
phase inverters meet all applicable CE for real time communications,
requirements and are approved by the monitoring and control
TÜV Rheinland. Multiple inverters can be paralleled
for large power installations
The GT250E/GT500E are
manufactured in Germany

Springerville solar array installation

10
Solar Inverters

GT100E Grid Tie Inverter

Electrical Specifications
Continuous power rating 100 kW AC
Nominal DC power rating 105 kW DC
Nominal AC voltage 400 Vac three phase
Nominal AC frequency 50 Hz
Line power factor > 0,99 above 20% rated power
Maximum AC line current 164 Aac
AC current distortion < 3% THD at rated power
Max. open circuit voltage 650 Vdc
Power tracking window range 300 to 650 Vdc
Max. DC input current 319 Adc
Peak inverter efficiency 96,6% (includes transformer)
European weighted efficiency 96%
Standby tare losses 93 W

General Specifications
Ambient temperature range -10ºC to 45ºC
Enclosure environmental rating IP21
Enclosure Rittal TS Series
Weight 870 kg
Dimensions (H x W x L) 190,5 x 120,5 x 60,6 cm
Altitude up to 2000 m without de-rating
Relative humidity 0 to 95% non-condensing

Features & Options


Cooling method Forced convection cooling
Protective functions AC over / under voltage, AC over / under frequency, over temperature, AC and DC over current, DC over voltage
User display standard Four-line, 80-character VFD with a keypad
Disconnects (AC & DC) Integral to inverter assembly
Isolation transformer Integral to inverter assembly
Communications software Serial communications and control software
Data acqusition and logging Adjustable
Interfaces Telephone modem for remote monitoring and faults notification via modem, RS232

Regulatory Approvals
The GT100E is compliant to applicable European directives and CE marked :
EMC Directive EN 50081-2, EN 50082-2
Low Voltage Directive EN 50178
The GT100E complies with the requirements of VDEW
The GT100E is approved by the TÜV Rheinland
The GT100E complies with the requirements of the Royal Decree, Spain
Note: Specifications subject to change without notice.

11
GT Inverters: GT100E/GT250E/GT500E (Three phase)

GT250E Grid Tie Inverter

Electrical Specifications
Continuous power rating 250 kW AC
Nominal AC voltage 315 Vac three phase (other voltage levels on request)
Nominal AC frequency 50 Hz (60 Hz on request)
Line power factor > 0,99 above 20% rated power
AC current distortion < 3% THD at rated power
Maximum AC line current 460 Vdc
Standby tare losses < 100 W
Night consumption < 100 W
Minimum DC voltage for feed-in 450 Vdc
Suggested PV power 280 kWp
Maximum DC current 555 A
Maximum open circuit voltage 880 Vdc (optional 880 Vdc)
Power tracking window range 450 to 800 Vdc
Maximum efficiency 97,5% at medium voltage level
European efficiency 96,6% at medium voltage level

General Specifications
Ambient temperature range -10°C to 45°C
Enclosure environmental rating IP21
Enclosure Rittal TS Series
Weight 1160 kg
Dimensions (H x W x L) 211,2 x 200,6 x 60,5 cm
Altitude up to 1500 m without de-rating
Relative humidity 0 to 95% non-condensing

Features & Options


Cooling method Forced convection cooling
Protective functions AC over / under voltage, AC over / under frequency, over temperature, AC and DC over current, DC over voltage
User display standard LCD, four-line, 20-character with keypad
Disconnects (AC & DC) Integral to inverter assembly
Communications software Graphical user interface software for real time communications and control
Data acquisition and logging Adjustable
Combiner boxes Optional feature (information on request)
Container solution Optional feature (information on request)

Regulatory Approvals
The GT250E is compliant to applicable European directives
The GT250E complies with the requirements of VDEW
The GT250E complies with the requirements of the Royal Decree, Spain

Note: Specifications are subject to change without notice

12
Solar Inverters

GT500E Grid Tie Inverter

Electrical Specifications
Continuous power rating 500 kW AC
Nominal AC voltage 315 Vac three phase (other voltage levels on request)
Nominal AC frequency 50 Hz (60 Hz on request)
Line power factor > 0,99 above 20% rated power
AC current distortion < 3% THD at rated power
Maximum AC line current 920 A
Stand-by tare losses < 100 W
Night consumption < 100 W
Minimum DC voltage for feed-in 450 V
Suggested PV power 560 V
Maximum DC current 1120 V
Maximum open circuit voltage 880 Vdc
Power tracking window range 450 to 800 Vdc
Peak efficiency 98,1%
European efficiency 97,3%

General Specifications
Ambient temperature range -10ºC to 45ºC
Enclosure environmental rating IP21
Enclosure Rittal TS Series
Weight 1770 kg
Dimensions (H x W x L) 211,2 x 240,6 x 60,5 cm
Altitude up to 1500 m without de-rating
Relative humidity 0 to 95% non-condensing

Features & Options


Cooling method Forced convection cooling
Protective functions AC over / under voltage, AC over / under frequency, over temperature, AC and DC over current, DC over voltage
User display Standard LCD, four-line, twenty characters with keypad
Disconnects (AC & DC) Integral to inverter assembly
Communications software Graphical user interface software for real time communications and control
Data acqusition and logging Adjustable
Interfaces Webserver or telephone modem for remote system monitoring and fault notification
Combiner boxes Optional feature (information on request)
Container solution Optional feature (information on request)

Regulatory Approvals
The GT500E is compliant to applicable European directives and CE marked
The GT500E complies with the requirements of VDEW
The GT500E complies with the requirements of the Royal Decree, Spain

Note: Specifications are subject to change without notice

13
XW Hybrid Inverter/Charger

The next generation inverter/charger for renewable energy systems and backup power applications

Xantrex brings the next generation of Features Optional Accessories


inverter/charger to market, with the
True sine wave output XW Conduit Box
XW Hybrid Inverter/Charger, the heart
Single phase (230 Vac) and three phase XW Solar Charge Controller
of the XW System. The XW Hybrid
Inverter/Charger (XW) is a true sine (400/230 Vac) configurations possible XW System Control Panel
Dual AC inputs XW Automatic Generator Start
wave inverter/charger that incorporates
Several units can be connected
a DC to AC inverter, a battery charger,
and an AC auto-transfer switch. It is the in parallel
XanBus™-enabled network
foundation for battery-based residential
and commercial applications up to 18 communication
Unprecedented surge capacity
kilowatts (kW). Capable of being grid-
Efficient, power factor corrected, high-
interactive or grid-independent, the
XW can operate with generators and current, multistage battery charging
renewable energy sources to provide
full-time or backup power. Up to three
inverters can be installed to create larger
single-phase and three-phase systems
allowing for increased capacity.

Designed with consultation and input


from industry experts, dealers, and
installers, the XW sets a new standard
for battery-based inverter/chargers.
Integrating the best features available
in the market, innovative new features
by Xantrex and balance-of-systems
components, the XW Hybrid Inverter/
Charger’s design makes installation
quicker and easier. The XW offers high
efficiency and unprecedented surge
capacity to maximize the owner’s return
on investment. No other inverter/charger
looks or performs like the XW.

14
Inverter/Chargers

Electrical Specifications
Model XW6048-230-50 XW4548-230-50 XW4024-230-50
Continuous output power 6000 W 4500 W 4000 W
Surge rating 12000 W 9000 W 8000 W
Surge current 53 A rms 40 A rms 35 A rms
Waveform True sine wave True sine wave True sine wave
Peak efficiency 95,4% 95,6% 94%
Idle consumption - search mode < 7 W < 7 W <7W
AC connections AC1 (grid), AC2 (generator) AC1 (grid), AC2 (generator) AC1 (grid), AC2 (generator)
AC input voltage range (bypass/charge mode) 156 to 280 Vac (230 V nominal) 156 to 280 Vac (230 V nominal) 156 to 280 Vac (230 V nominal)
AC input frequency range (bypass/charge mode) 40 to 68 Hz (50 Hz nominal) 40 to 68 Hz (50 Hz nominal) 40 to 68 Hz (50 Hz nominal)
AC output voltage 230 Vac +/- 3% 230 Vac +/- 3% 230 Vac +/- 3%
Maximum AC pass through current 56 A 56 A 56 A
AC output continuous current 26,1 A 19,6 A 17,4 A
AC output frequency 50 Hz +/- 0,1 Hz 50 Hz +/- 0,1 Hz 50 Hz +/- 0,1 Hz
Total harmonic distortion < 5% at rated power < 5% at rated power < 5% at rated power
Typical transfer time 8 ms 8 ms 8 ms
DC current at rated power 131 A 96 A 178 A
Utility-interactive Disabled (default), AC voltage range 198 to 253 Vac, AC frequency range 49,1 to 50,9 Hz
DC input voltage range 44 to 64 V 44 to 64 V 22 to 32 V
Continuous charge rate 100 A 85 A 150 A
Power factor corrected charging PF (0,98) PF (0,98) PF (0,98)

Mechanical Specifications
Mounting Wall mount, backplate included
Inverter dimensions (H x W x D) 58 x 41 x 23 cm 58 x 41 x 23 cm 58 x 41 x 23 cm
Inverter weight 57 kg 52 kg 52 kg
Shipping dimensions 71,1 x 56,5 x 26,7 cm 71,1 x 56,5 x 26,7 cm 71,1 x 56,5 x 26,7 cm
Shipping weight 60 kg 55 kg 55 kg
Supported battery types Flooded (default), Gel, AGM, custom Flooded (default), Gel, AGM, custom Flooded (default), Gel, AGM, custom
Battery bank size 100 to 10000 Ah 100 to 10000 Ah 100 to 10000 Ah
Battery temperature sensor Included Included Included
Non volatile memory Yes Yes Yes
Display panel Status LEDs indicate AC In status, faults/warnings, equalize mode, On/Off and equalize button battery level.
Three-character display indicates output power or charge current
Multiple unit configurations Single phase: up to 3 parallel units. Three-phase: 1 unit per phase
System network Xanbus™ Xanbus™ Xanbus™
Warranty Five years Five years Five years

Environmental Specifications
Enclosure type IP 20 (sensitive electric components sealed inside enclosure)
Operational temperature range -25°C to 70°C -25°C to 70°C -25°C to 70°C

Accessories
Remote display Optional XW System Control Panel monitors and configures all devices connected to Xanbus™ Network
Generator support Optional XW Automatic Generator Start module connects to Xanbus™ Network. Automatically activates generator to recharge
depleted battery bank or assist inverter with heavy loads
Conduit Box Optional XW Conduit Box encloses the bottom of the inverter and protects the cabling. Provides knockouts for 2 cm,
2,5 cm, 3,2 cm, 6 cm, and 6,5 cm conduit
Solar Charge Controller Optional XW Solar Charge Controller with MPPT delivers the maximum energy available from the PV array to the battery bank

Regulatory Approval
CE marked according to the following EU directives and standards:
EMC Directive EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3
Low Voltage Directive EN50178
Note: Specifications are subject to change without

15
Trace Series Inverter/Charger

230 Vac / 50 Hz models inverter/chargers

Based on the proven technology of the Features Options


Xantrex™ DR Series, the Xantrex™ Trace
Series Inverter/Charger is an economical New digital display shows kilowatts TR-Remote On/Off Switch – includes
power conversion solution designed (kW) when inverting and amps (A) LED status indicator
to provide dependable modified sine when charging, plus incorporates a
TR-Conduit Box – connects to the DC
wave electricity to essential circuits robust ON/OFF membrane switch
side of the inverter and accepts 2 cm,
in the home or business during a and status indicators
New power factor corrected (PFC) 2,5 cm or 5 cm conduit
power outage. It can also be used in
conjunction with a generator or any charging, combined with a more
renewable energy source in an off-grid sophisticated multi-stage battery
application. In addition to providing charging algorithm, reduces
new features, the Trace Series improves electricity draw and generator
on the key features that have made the run-time
DR Series the most robust and reliable Simplified controls with a snap-on
inverter/charger line for backup power cover that protects settings from
and off-grid applications. being accidentally changed
Better thermal performance allows
full output power to 50°C
without de-rating
High surge capacity starts more
difficult loads and handles overload
conditions reliably
Circuit boards are conformally-
coated to protect them from
corrosion for longer life and
improved reliability
Durable powder coated, corrosion
resistant steel chassis

16
Inverter/Chargers

Electrical Specifications
Model TR1512-230-50 TR1524-230-50 TR2424-230-50
Invert mode
Waveform Modified sine wave Modified sine wave Modified sine wave
Continuous output power 1500 VA 1500 VA 2400 VA
AC output voltage (rms) 230 Vac 230 Vac 230 Vac
AC output frequency 50 Hz 50 Hz 50 Hz
Rated AC output current 6,5 Aac 6,5 Aac 10,4 Aac
Surge capability max. output & duration:
Overload 10 sec rating 3000 VA 3000 VA 4800 VA
Short Circuit 10 sec rating 26,5±2,5 Apk 26,5±2,5 Apk 42±4 Apk
Adjustable load sensing range 10 to 480 W 10 to 480 W 10 to 480 W
DC input current at no load - search mode 0,35 A 0,20 A 0,20 A
Efficiency - peak > 92% > 91% > 94%
DC input voltage range 11 to 15 Vdc 22 to 30 Vdc 22 to 30 Vdc
Rated DC input current 158 A 77 A 121 A
Load power factor (allowed) 0,8 to 1,0 (leading or lagging) 0,8 to 1,0 (leading or lagging) 0,8 to 1,0 (leading or lagging)
Series operation No No No
Bypass / Charge mode:
AC input voltage range 120 to 253 Vac (wide), 180 to 253 Vac (narrow) 120 to 253 Vac (wide), 180 to 253 Vac (narrow) 120 to 253 Vac (wide), 180 to 253 Vac (narrow)
AC input frequency range 45 to 55 Hz (narrow-charge and pass-through), 45 to 68 Hz (wide-charge), 41 to 68 Hz (wide pass-through)
Built-In internal supplemental breakers 15 Aac bypass, 8 Aac charger 15 Aac bypass, 8 Aac charger 15 Aac bypass, 15 Aac charger
DC charger rate (adjustable) 10 to 70 A 5 to 35 A 10 to 70 A
AC input current at max. charge rate 5,9 A 6,0 A 10,4 A
AC input power factor 0,91 > 0,83 0,92
Multi-stage charging Yes - bulk, absorption and float, plus user-initiated equalize (for flooded batteries only)
Temperature compensation Battery temperature sensor included Battery temperature sensor included Battery temperature sensor included
Automatic transfer relay 15 amps 15 amps 15 amps
Transfer time (typical) < 40 ms (wide), < 20 ms (narrow) < 40 ms (wide), < 20 ms (narrow) < 40 ms (wide), < 20 ms (narrow)

Environmental Specifications
Dimensions (W x H x L) 21,6 x 18,4 x 54,6 cm 21,6 x 18,4 x 54,6 cm 21,6 x 18,4 x 54,6 cm
Weight 19 kg 18 kg 20 kg
Shipping Dimensions (W x H x L) 31,5 x 30 x 67,5 cm 31,5 x 30 x 67,5 cm 31,5 x 30 x 67,5 cm
Shipping Weight 23,6 kg 23,6 kg 23,6 kg
Operating temperature range 0°C to 50°C 0°C to 50°C 0°C to 50°C
Mounting Wall-mount Wall-mount Wall-mount
Warranty Two years Two years Two years

Regulatory Approvals
CSA Certified to CSA 107.1, UL1741, FCC Class B and Industry Canada, CE

Note: Specifications subject to change without notice.

17
Prosine Inverters

1000 W and 1800 W 230 Vac / 50 Hz sine wave inverters

Offering superior quality sine wave Product Features Options


output, the Prosine 1000i and Prosine
Two models available: 1000 W Available in 12 and 24 volt models
1800i stand-alone inverters are ideal
(1500 W surge) and 1800 W Schuko AC receptacle
for electrical systems that already have
(2900 W surge) Remote interface kit for remote
a quality multistage battery charger.
True sine wave output mounting of display module
Designed for recreational and indus-
Removable LCD display can be Models available with Schuko,
trial applications, Prosine inverters are
suitable for both heavy duty and sensi- mounted remotely for control hardwire, or hardwire with
tive electronic loads. The inverters and monitoring transfer switch
Unique DC terminals offer 180-
are lighter and more compact than
others with similar power ratings degree connections for easy
because they use high-frequency installation in tight places
Efficient powersave mode draws only
switching technology in the power
conversion process. 1,5 W under no load condition
Two year warranty

Ultra-Clean True Sine Protection Features


Wave Power Over temperature shutdown and
With less than 3% total harmonic dis- automatic overload protection
tortion, the Prosine delivers true sine Over voltage and under voltage Inverter Remote Display
wave output that is identical to AC protection
power supplied by your utility. Expect Short circuit and AC backfeed Prosine 1000E/1800
trouble-free true sine wave electricity protection
Remote Panel
for televisions, audio systems, variable This remote panel displays DC input
speed tools, and more. voltage from the battery, DC input
current (amps) drawn from the
battery, power scale with inverter
wattage output, and status/error
display for shutdown conditions
- overload, over-temperature, and
over/under voltage. Comes with
7,6 m cable.

18
Inverters

Electrical Specifications
Model Prosine 1000i Prosine 1800i
Output power 1000 W 1800 W
Surge rating 1500 W 2900 W
Peak output current 11 A 20 A
Output voltage (at no load) 230 Vac RMS +/-3% 230 Vac RSM +/-3%
Output voltage (over full load and battery voltage range) 230 Vac RMS +4%, -10% 230 Vac RMS +4%, -10%
Output frequency 50 Hz+/-0,05 (crystal controlled) 50 Hz+/-0,05 (crystal controlled)
Output waveform True sine wave (< 3% THD) True sine wave (< 3% THD)
Peak efficiency 90% 90%
No load power draw (search mode) < 1,5 W < 1,5 W
No load power draw (idle mode) < 22 W < 22 W
Input voltage range (12 V / 24 V) 10 to 16 Vdc / 20 to 32 Vdc 10 to 16 Vdc / 20 to 32 Vdc
Transfer relay rating (hardwire/transfer relay models) 10 A 10 A
Transfer time AC to inverter and inverter to AC Max 2 cycles (typically 1 cycle) < 2,5 seconds with Powersave “ON”

General Specifications
Operating temperature range 0°C to 60°C 0°C to 60°C
Storage temperature range -30°C to 70°C -30°C to 70°C
AC output types Hardwire Hardwire
Hardwire with transfer relay Hardwire with transfer relay
Schuko AC receptacle Schuko AC receptacle
LCD display panel Removable; can be mounted remotely (requires remote interface kit - see part number section)
Recommended DC fuse (12 V model) 175 A (depending on applicable installation codes) 300 A (depending on applicable installation codes)
Recommended DC fuse (24 V model) 90 A (depending on applicable installation codes) 100 A (depending on applicable installatin codes)
Dimensions (H x W x L) 11,5 x 28 x 39 cm 11,5 x 28 x 39 cm
Weight 7,0 kg 7,5 kg
Warranty Two years Two years

Regulatory Approvals
CE mark - Low Voltage Directive (EN50091-1), EMC Directive (EN50091-2)
e-mark - Automotive EMC Directive 95/54/EC

Note: Specifications subject to change without notice.

19
XPower Inverter 150, 300 & 500

12 Vdc to 230 Vdc / 50 Hz power inverters

XPower Inverter 150 / 300 XPower Inverter 500

Ideal for powering recreational mobile Product Features Protection Features


office equipment and other electronic
Available in 150, 300 or 500 W Over temperature shutdown
appliances, XPower Inverters convert
models Overload shutdown
12 volts of DC battery power in your
Offer 300, 600 or 1000 W surge Low voltage shutdown (at 10,0 Vdc)
vehicle to 230 volts of AC power. Avail-
capacity Over voltage shutdown (at 15,0 Vdc)
able in a range of sizes, the invert-
Available in three AC outlet Low voltage alarm (at 10,7 Vdc)
ers can power a variety of electronic
configurations: Schuko, UK Short circuit protection
products including TVs, VCRs, fax
and AUS/NZ LED indicator indicates fault
machines, laptop computers, cam-
Regulated output protects connection
corders, stereos, small power tools
and work lights. sensitive equipment
Compact size for convenient use

Choosing the right size of inverter for and storage


Auto shutdown prevents total
a particular application is important.
For example, the XPower Inverter 150 battery discharge
Mounting brackets for convenient
can run a laptop for approximately
9 hours from a 75 amp-hour battery; installation (XPower Inverter 300
the XPower 300 can run a 49 cm TV and 500)
for approximately 6 hours from a 75
amp-hour battery. The exact run time
depends on the amount of power
being drawn by the application and
the size and condition of the battery.
The XPower Inverter 500 can be used
instead of a generator for low power
or intermittent loads.

20
Inverters

Electrical Specifications
Models 150 300 500
Output power (continuous) 150 W 300 W 500 W
Surge capacity (peak) 300 W 600 W 1000 W
Output voltage 230 Vac +/- 5% 230 Vac +/- 5% 230 Vac +/- 5%
Output frequency 50 +/- 3Hz 50 +/- 3Hz 50 +/- 3Hz
Output waveform Modified sine wave Modified sine wave Modified sine wave
Peak efficiency 90% 90% 90%
No load current draw < 0,18 A < 0,2 A < 0,3 A
Input voltage range 10 to 15 Vdc 10 to 15 Vdc 10 to 15 Vdc

General Specifications
Operating temperature range 0°C to 40°C 0°C to 40°C 0°C to 40°C
AC receptacle Schuko, UK and AUS/NZ Schuko, UK and AUS/NZ Schuko, UK and AUS/NZ
Display Power ON and Fault LEDs Power ON and Fault LEDs Power ON and Fault LEDs
Battery connection DC lighter plug DC lighter plug or cable clamps Cable clamps and hardwire
Mounting bracket None Built-in Built-in
Internal DC fuse Not user replaceable Not user replaceable Not user replaceable
Dimensions (H x W x L) 6,3 x 10,4 x 15,7 cm 6,6 x 10,4 x 20 cm 6,6 x 11,2 x 24,1 cm
Weight 0,65 kg 0,79 kg 1,2 kg
Warranty Two years Two years Two years

Regulatory Approvals
XPower Inverter 150 CE, TUV/GS, e-mark
XPower Inverter 300/500 CE, TUV/Type approved, e-mark

Note 1: Specifications subject to change without notice.


Note 2: Specifications are based on 12-volt DC nominal input.
Note 3: When operating products that require high surge or continuous power over 150 W with the XPower Inverter 300 or 500, we recommend hard wiring the inverter directly to the battery.

21
XC Series Battery Chargers (12 V & 24 V)

15, 25, 30 and 50 A Smart Chargers

Xantrex XC Battery Chargers are Performance Features Protection Features


designed to provide longer battery
life by independently controlling the 12 V models available in 30 A and True reverse polarity protection
charge profile for each battery bank. 50 A (XC3012 and XC5012) (no fuses)
The XC is the first “smart” charger that 24 V models available in 15 A and IP32 environmental enclosure
can charge up to three different bat- 25 A (XC1524 and XC2524) rating against moisture
tery chemistries simultaneously. This Microprocessor-controlled, multi- Over temperature protection
unique multiplex design means that DC over voltage protection
boaters can choose the optimal bat- stage charging algorithms
tery type for each application on their Three independently controlled Ignition protection
boat without concern about battery output banks accommodate
damage from either under- different battery chemistries and
or overcharging. states of charge simultaneously
Settings for flooded, gel, AGM, lead-
Available in both 12 and 24 volt
models, XC Chargers are unmatched calcium or custom battery types
Auto-ranging universal input voltage
for reliability. In addition to meeting
global safety and emission standards, (100-260 Vac, 47-63 Hz) is also
XC Chargers feature a unique drip- compatible with generator or other
proof design and fuseless reverse low quality power sources
polarity protection to ensure trouble- Independent temperature
free charging.
compensated charging on each
Designed primarily for marine of the three output banks
applications, XC Chargers are versatile Power Factor Corrected for
enough to be used in a wide variety efficient charging
of conditions and locations. Auto- Battery equalization feature
ranging AC input voltage capability Upgradeable for network
(100-260 Vac) makes traveling abroad
and handling poor quality power communications
Invertible and detachable
a breeze. The easy-to-read digital
display is invertable to accommodate digital display
either horizontal or vertical Ability to charge ‘dead’ batteries
installations, and can be detached (< 6 V)
and mounted wherever needed. An Includes one battery temperature
optional intelligent shunt provides
sensor; additional battery
a simple “fuel gauge” capability that
displays amp-hours consumed from temperature sensors available
a selected battery bank. (part #808-0232-01)
Optional intelligent shunt available
(part #808-8020-00) to measure
amp-hours consumed

22
Battery Chargers

Electrical Specifications
Models XC3012 XC5012 XC1524 XC2524
Output current 30 A 50 A 15 A 25 A
Output voltage 12 Vdc 12 Vdc 24 Vdc 24 Vdc
Input voltage 100 to 260 Vac 47 to 63 Hz 100 to 260 Vac 47 to 63 Hz 100 to 260 Vac 47 to 63 Hz 100 to 260 Vac 47 to 63 Hz
Power factor correction Yes Yes Yes Yes
Multi-stage charging Selectable 2 stage, 3 stage, or custom
Temperature compensation 3 channels 3 channels 3 channels 3 channels
Charger efficiency (nominal) 80% 80% 83% 83%
Battery types accommodated AGM, PBCa Gel, or flooded on any channel
Recommended battery size > 60 Ah > 100 Ah > 30 Ah > 50 Ah

General Specifications
Operating temperature range 0°C to 50°C (50°C to 65°C de-rated)
Storage temperature -40°C to 80°C -40°C to 80°C -40°C to 80°C -40°C to 80°C
DC output connections M6 Studs M6 Studs M6 Studs M6 Studs
AC input connections Hardwire Hardwire Hardwire Hardwire
Dimensions (H x W x L) 10,6 x 24 x 36,8 cm 10,6 x 24 x 36,8 cm 10,6 x 24 x 36,8 cm 10,6 x 24 x 36,8 cm
Weight 5 kg 6 kg 5 kg 6 kg
Digital remote display Included Included Included Included
Battery temperature sensor 1 included 1 included 1 included 1 included
Warranty Two years Two years Two years Two years

*Including mounting flanges

Options
Battery temperature sensor for 2nd and 3rd banks - all models
Easy shunt / Battery monitor for all models

Regulatory Approvals
Meets CSA 107.2, UL 1564, UL 1236 including marine supplement, ignition protection
EMC FCC Class B
CE marked, meeting LVD and EMC directives, as well as VCA compliance (e-mark)

Note: Specifications subject to change without notice.

23
XPower Powerpack 175 Plus

175 100
From W portable AC power
kW to 500 with 17 Bar
kW Three-Phase (250Conversion
Power psi) air compressor
Center

Portable Powerpacks keep you Product Features Applications


untethered. Whether you are at the
Runs 230 Vac or 12 Vdc For emergency situations:
beach, camping or just plain far from
products anywhere Jump-starts vehicles (4-cylinder and
a household electrical outlet, you
Built-in 175 W inverter most 6-cylinder engines)
can still run all the electronic con-
17 bar air compressor Charges cordless and cellular phones
veniences that you depend on. The
Sealed, non-spillable 12 amp-hour Powers emergency light and radios
XPower Powerpack 175 Plus allows you
AGM battery Inflates vehicle tires
to power blenders, stereos, or portable
Reverse polarity detector for safely
DVD players when you are on the go.
With one AC outlet and one DC socket, jumpstarting your vehicle For outdoor and indoor applications:
Jumper clips designed for easy Powers camcorders, stereos,
it can run a variety of devices while
delivering a maximum of 175 watts of storage on the unit 33 cm TV
Built-in light provides illumination Runs fans, computers, laptops,
power. This Powerpack also includes a
built-in light, an air compressor and a in emergency situations at home portable stereos and clock radios,
vehicle jump start feature to help you and on the road game consoles and more
Bar-graph LED indicator for
in emergency situations.
monitoring the Powerpack’s battery
charge level
Audible alarm signals unit overheat
and battery under voltage condition
Recharge at home or from a vehicle
Protective covers for the DC
power outlets

Accessories
AC Charger - recharge XPower
Powerpack 175 Plus from a standard
wall outlet
DC Charging Cable - recharge
XPower Powerpack 175 Plus
from your vehicle
Nozzle Adapters - pump air into your
vehicle tyres or small inflatable
sports equipment

24
Powerpacks

Electrical Specifications
230 volt AC section 12 volt DC section
AC output power (max. continuous) 140 W Internal battery type Sealed lead acid, AGM
AC output power (5 minutes) 175 W Internal battery capacity 12 amp-hours, 120 CCA
AC surge power (peak) 280 W Internal battery voltage 12 Vdc (nominal)
AC output voltage (nominal) 230 V DC power socket (circuit breaker) 12 amps (automatic reset)
AC output frequency 50 Hz +/- 2 Hz
AC output waveform Modified sine wave
Inverter no-load current < 0,2 amps (battery drain with no load on inverter)
Charging system Charging time
AC charger bulk charging current 500 mA (maximum) From AC outlet max. 24 hours*
Peak charging voltage 14,2 V (nominal) From DC outlet max. 2,5 hours*
Charge restart voltage 12,9 V (nominal) *Maximum charging time occurs when battery is completely discharged.
Float charge current 1 mA (nominal)
Charger input socket current 2,5 A (maximum)

General Specifications
Jump-start cables 61 cm, 8 AWG
Air compressor 17 bar
Built-in incandescent light 5 W (replaceable)
Operating/storage temperature 0°C to 40°C / 0°C to 30°C
AC receptacle UK, Schuko
Inverter low battery alarm 11 V (nominal)
Inverter low battery shutdown 10,5 VS (nominal)
Dimensions (H x W x L) 22,1 x 15,5 x 31,5 cm
Weight 5,4 kg
Warranty Two years

Regulatory Approval
XPower Powerpack 175 Plus CE, e-mark

Note: Specifications subject to change without notice.

25
XPower Powerpack 300 Plus

Portable power packs 230 Vac / 50 Hz

022097

XPower Powerpack 300 Plus by Xan- XPower Powerpack 300 Plus Accessories
trex provides maximum 300 watts of
230-volt AC and 12-volt DC outlets Jumper Cables – use the XPower
silent household (AC) and DC power
anytime, anywhere. It’s a convenient to power most small household Powerpack to jump start vehicles
appliances AC Charger – recharge the XPower
source of power for year-round use
Built-in 300 watt inverter with Powerpack from a standard
and it’s ideal for weather emergencies,
power outages and car breakdowns. sealed, non-spillable 20 amp-hour wall outlet
AGM battery DC Charging Cable – use the XPower
The XPower Powerpack 300 Plus
17 bar air compressor to Powerpack to power DC-compatible
integrates a power source for small
AC and DC appliances, an emergency inflate vehicle tires and small appliances or to recharge the
light, and a vehicle battery booster. It sports equipment Powerpack from a car, truck,
Smart circuitry protects against SUV or RV
also includes a 17 bar air compressor.
reverse polarity jumpstart Nozzle Adapters pump air easily into
As the market for portable electronic
devices grows, so does the need to connections vehicle tires or small inflatable
Built-in fluorescent lights provide sports equipment
power these devices. The XPower Pow-
illumination in emergency situations Accessory bag – helps keep XPower
erpack provides the power to improve
AC and DC charger cables allow Powerpack’s accessories together
safety, efficiency and the quality of
daily life. recharging from home or in vehicle
Battery level meter to easily monitor
the status of the Powerpack battery
Applications
AC charger offers battery overcharge For outdoor use:
protection Pump air into small inflatable sports
Audible alarm signals when the unit equipment
begins to overheat, and in times Power camcorders, video games,
of under voltage conditions stereos, 33 cm TV/VCR, TV/DVD
Electrical current overload and combos, computers, laptops, clock
overheating protection ensure radios, and small power tools
a longer Powerpack life
For emergency situations:
Inflate vehicle tires
Jump-start vehicles
Power emergency lights, TVs,
and radios

26
Powerpacks

Electrical Specifications
230 volt AC section
AC output power 250 W (max. continuous)
AC output power 300 W (5 minutes)
AC surge power 500 W (peak)
AC output voltage 230 V (nominal)
AC output frequency 50 Hz +/-4 Hz
AC output waveform Modified sine wave
Inverter no-load current < 0,2 amps

12 volt DC section
Internal battery type Sealed lead acid, AGM
Internal battery capacity 20 amp-hours, 200 CCA
Internal battery voltage 12 Vdc (nominal)
DC power socket (circuit breaker) 12 A (automatic reset)
Cold cranking amps 200 A

Charging system
AC charger bulk charging current 500 mA (maximum)
Peak charging voltage 14,5 V (nominal)
Charge restart voltage 12,9 V (nominal)
Float charge current 1 mA (nominal)

Charging time
From AC outlet Max. 40 hours*
From DC outlet Max. 4 hours*

* Maximum charging time occurs when battery is completely discharged.

General Specifications
Air compressor 17 bar
Jump-start cables 1 meter, 8 AWG
Built-in fluorescent lamp Two, 4 W bulbs (replaceable)
Operating temperature 0°C to 40°C
Storage temperature 0°C to 30°C
AC receptacle Schuko, UK and AUS/NZ
Inverter low battery alarm 10,7 V (nominal)
Inverter low battery shutdown 10 V (nominal)
Dimensions (H x W x D) 30 x 18,2 x 31,8 cm
Weight 9 kg
Warranty Two years

Note: Specifications subject to change without notice.

27
XPower Powerpack 400 Plus

400 W portable AC power with 17 Bar (250 psi) air compressor

Portable Powerpacks keep you Product Features Accessories


untethered. With a bigger battery and
Runs 230 Vac or 12 Vdc Jumper cables - use XPower
heavy-duty jumper cables, the XPower
Powerpack 400 Plus not only jump- products anywhere Powerpack 400 Plus to jump-start
Built-in 400 W inverter your vehicle
starts vehicles up to eight cylinders,
Sealed, non-spillable 20 amp-hour Nozzle adapters - pump air into your
it also offers extended runtime for
your electronics when and where you AGM battery vehicle tyres or small inflatable
17 bar air compressor for sports equipment
need it. Whether you are at the beach,
inflating tyres and small sports AC charger - recharge XPower
camping or just far from a household
electrical outlet you can still run all equipment Powerpack 400 Plus from a standard
Jumper cables designed for safe wall outlet
the electronic conveniences that you
and efficient jump-starting DC charging cable - recharge
depend on. This Powerpack allows
Built-in light provides illumination XPower Powerpack 400 Plus from
you to power blenders, stereos, por-
table DVD players or 51 cm TV/DVD in emergency situations at home your car, truck, boat or caravan
and on the road Accessory bag
combos when you are on the go. With
3-digit display allows for easy battery
one AC outlet and one DC socket,
it can run a variety of devices while status monitoring Applications
Audible alarm signals overheat and
delivering a maximum of 400 watts of For outdoor and indoor applications:
power – just enough to power small under voltage conditions Pumps air into small inflatable
Overload and over-temperature
electrical drills and other power tools sports equipment
that come in handy when doing minor protection Powers camcorders, video games
Recharge at home or from a vehicle
repairs in or around your house. The consoles, stereos, 51 cm TV/
XPower Powerpack 400 Plus also VCR combos
includes a built-in light and an air Runs fans, computers, laptops, clock
compressor to help you in emergency radios, small power tools
situations.
For emergency situations:
Inflates tires
Jump-starts vehicles (6-cylinder
and most 8-cylinder engines)
Charges cordless and cellular phones
Powers emergency lights, TVs
and radios

28
Powerpacks

Electrical Specifications
230 volt AC section 12 volt DC section
AC output power (max. continuous) 320 W Internal battery type Sealed lead acid, AGM
AC output power (5 minutes) 400 W Internal battery capacity 20 amp-hours, 200 CCA
AC surge power (peak) 640 W Internal battery voltage 12 Vdc (nominal)
AC output voltage (nominal) 230 V DC power socket (circuit breaker) 12 amps (automatic reset)
AC output frequency 50 Hz +/-4 Hz
AC output waveform Modified sine wave
Inverter no-load current < 0,2 A (battery drain with no load on inverter)
Charging system Charging time
AC charger bulk charging current 500 mA (maximum) From AC outlet max. 40 hours*
Peak charging voltage 14,2 V (nominal) From DC outlet max. 4 hours*
Charge restart voltage 12,9 V (nominal) *Maximum charging time occurs when battery is completely discharged.
Float charge current 1 mA (nominal)
Charger input socket current 2,5 A (maximum)

General Specifications
Air compressor 17 bar
Jump-start cables 61 cm, 6 AWG
Built-in incandescent light 5 W (replaceable)
Operating/storage temperature 0°C to 40°C / 0°C to 30°C
Inverter low battery alarm 11 V (nominal)
Inverter low battery shutdown 10,5 V (nominal)
Dimensions (H x W x L) 24,2 x 20,6 x 40,2 cm
Weight 9 kg
Warranty Two years

Regulatory Approval
XPower Powerpack 400 Plus CE, e-mark

Note: Specifications subject to change without notice.

29
XW Solar Charge Controller

Photovoltaic charge controller for 12, 24, 36, 48, and 60-volt DC battery systems

The Xantrex™ XW Solar Charge The XW SCC incorporates a dynamic Configurable auxiliary output
Controller (XW SCC) is a photovoltaic Maximum Power Point Tracking Two-line, 16-character liquid crystal
(PV) charge controller that tracks the (MPPT) algorithm designed to display (LCD) and four buttons for
electrical maximum power point of maximize energy harvest from the PV configuration and system monitoring
a PV array to deliver the maximum array. The MPPT constantly adjusts Input over-voltage and under-
available current for charging the operating points of the array voltage protection, output over-
batteries. When charging, the XW SCC to ensure it stays on the maximum current protection, and backfeed
regulates battery voltage and output power point. It does not stop energy (reverse current) protection (warning
current based on the amount of harvest to sweep the array like some and fault messages appear on LCD
energy available from the PV array and other competing products. This when unit shuts down as
state-of-charge of the battery. feature is beneficial all sunlight a protective measure)
conditions, especially in areas with Over-temperature protection and
The XW SCC can be used with 12, 24, fast moving cloud cover and quickly power derating when output power
36, 48, and 60-volt DC battery systems changing solar conditions. and ambient temperature are high
and is able to charge a lower nominal- Battery Temperature Sensor (BTS)
voltage battery from a higher nominal- Product Features included − automatically provides
voltage array. For example, the XW Maximum Power Point Tracking temperature compensated
SCC can charge a 12-volt battery from battery charging
(MPPT) delivers maximum available Xanbus™-enabled network
a 36-volt array. This provides flexibility
power from PV array to battery bank
for installers to use longer wiring runs Integrated PV ground-fault communications protocol
without compromising efficiency. (developed by Xantrex)
protection Five-year warranty
The XW Solar Charge Controller can Ultra-reliable, convection-cooled
be installed (in single or multi-unit
design does not require a cooling
configurations) with Xantrex XW
fan − large, aluminum, die-cast
Hybrid Inverter/Charger(s) or can be
heat-sink allows full output current
used in other solar energy systems
up to 45°C without thermal derating
where a solar charge controller is Selectable two or three-stage
needed.
charging algorithms with manual
equalization to maximize system
performance and improve
battery life

30
XW Solar Charge Controller

Electrical Specifications
Nominal battery voltage 12, 24, 36, 48, 60 Vdc
Maximum PV array voltage (operating) 140 Vdc
Maximum PV array open circuit voltage 150 Vdc
Array short-circuit current 60 Adc maximum
Maximum and minimum wire size in conduit #6 AWG to #14 AWG
Total power consumption while operating 2,5 W (tare)
Charger regulation method: Three-stage (bulk, absorption, float)
Two-stage (bulk, absorption)

Mechanical Specifications
Dimensions (H x W x D) 36,8 x 14,6 x 13,8 cm
Weight (controller only) 4,8 kg
Weight (shipping) 8 kg
Shipping dimensions (H x W x D) 48,3 x 22,9 x 35 cm
Mounting Vertical wall mount
Standard warranty Five years

Environmental Specifications
Enclosure type Indoor, ventilated, sheet metal chassis with 2.2 cm and 2.8 cm knockouts and aluminium heat-sink
Operating temperature range (full power) -20°C to 45°C
Storage temperature -40°C to 85°C
Altitude limit (operating) Sea level to 4572 m @ 15°C

Regulatory Approvals
Certified to CE, UL1741

Note: Specifications subject to change without notice.

31
Charge Controllers

Small system charge or lighting or load controller

C12 Features Optional Accessories


The C12 charge, lighting, or load Silent, pulse width modulated
controller is uniquely sophisticated. microprocessor control
As a charge controller, it features (maximizing battery life)
three-stage charging, user definable Field adjustable voltage and battery
voltage parameters and automatic type set points
equalization. Standard in the C12’s Electronic protection against short-
load control circuitry are field circuit, overload, over temperature,
adjustable low voltage disconnect and reverse polarity conditions
and reconnect points, along with a
five minute low battery disconnect C12 CM and CM/R
warning. The C12 also functions as a
BTS: Battery temperature sensor Digital Meter or Remote Display
lighting controller. Lighting run time is This digital meter mounts onto the
adjustable from two to eight hours or front of a charge controller or as a
can be set for dusk to dawn operation. C Series remote it can be installed up to 31m
CM: Cumulative amp hour meter away. It displays volts, amps, and
C Series resettable cumulative amp hours for
CM/R: Remote cumulative amp
The C35 and C60 are field configurable hour meter (available in 50 or 100 a solar array, DC loads, or diversion
for 12- and 24- Vdc operation. The loads, depending on the application.
foot lengths)
The CM/R comes with 15 m or 31m
C40 may be configured for 12-, 24-, or BTS: Battery temperature sensor
communication cable for remote
48- Vdc operation. All can be used as
installation.
a charge, diversion, or load controller
and come with a standard multi-color
charge status LED.

32
C Series Controllers

Electrical Specifications
Model C35 C40 C60
Voltage configurations 12 and 24 Vdc 12, 24, and 48 Vdc 12 and 24 Vdc
Max. PV open circuit array voltage 55 Vdc 125 Vdc 55 Vdc
Charging / load current (@ 25°C) 35 Adc 40 Adc 60 Adc
Max. peak current 85 A 85 A 85 A
Max. voltage drop through controller 0,30 V 0,30 V 0,30 V
Typical operating consumption 15 mA 15 mA 15 mA
Typical idle consumption 3 mA 3 mA 3 mA
Recommended breaker size 45 A 50 A 60 A rated at 100% continuous duty
Recommended wire size #8 AWG #8 AWG #6 AWG rated at 90°C
Lead acid battery settings Adjustable Adjustable Adjustable
NiCad battery settings Adjustable Adjustable Adjustable
Load control mode Low voltage reconnect - adjustable (sticker provided with unit) all models
Low voltage disconnect - user selectable manual or automatic reconnection - (includes warning flash before disconnect
and provides a one time, user selected grace period) all model

General Specifications
Specified temperature range 0°C to 40°C 0°C to 40°C 0°C to 40°C
Enclosure type Indoor, ventilated, powder coated steel with 2 cm and 2.5 cm knockouts
Unit weight 1,2 kg 1,4 kg 1,4 kg
Shipping 1,4 kg 1,6 kg 1,6 kg
Dimensions (H x W x L) 20,3 x 12,7 x 6,4 cm 25,4 x 12,7 x 6,35 cm 25,4 x 12,7 x 6,35 cm
Shipping dimensions (H x W x L) 31,5 x 17,8 x 6,4 cm 31,5 x 17,8 x 6,4 cm 31,5 x 17,8 x 6,4 cm
Mounting Vertical wall mount - indoor only
Altitude - operating 4,572 m
Altitude - non-operating 15,240 m
Warranty Two years
Part numbers C35, C40, C60 - Controllers
CM - Front display panel
CM/R-50, CM/R-100 - Remote display panel
BTS - Battery temperature sensor

Features & Options


Regulation method Solid state, three-stage (bulk, absorption, and float), pulse width modulation
Field adjustable control setpoints Two user adjustable voltage setpoints for control of loads or charging sources - settings retained if battery is disconnected
Display panel CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage,
cumulative amp hours, and amp hours since last reset - remote includes 15 m or 30,5 m cable
Equalization charge User selectable manual or automatic equalization - every 30 days
Battery temperature sensor BTS - optional remote battery temperature sensor for increased charging precision

Regulatory Approvals
CE compliant , UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards

Note: Specifications subject to change without notice.

33
C12 Controller

Electrical Specifications
Maximum PV amps 12 A at 12 Vdc only
Maximum DC load 12 A with auto reset
Minimum operating voltage 6V
Maximum voltage drop - PV to battery 0,3 V
Maximum voltage drop - battery to DC load 0,5 V
Regulation setting 13 to 15 Vdc
Equalize setting Bulk plus 1 volt for two hours
Typical consumption while charging 0,007 A
Typical consumption at night 0,003 A
Typical consumption with load disconnected 0,003 A
Maximum stranded wire size #10 AWG stranded (5.2 mm2)

General Specifications
Allowed temperature range 0°C to 40°C
Enclosure type Powder coated steel with strain relief for wiring and knockouts for up to three ½" conduits
Unit weight 0,9 kg
Shipping weight 1,13 kg
Dimensions (H x W x L) 16,5 x 11 x 4 cm
Shipping dimensions (H x W x L) 20,3 x 11,7 x 4 cm
Mounting Vertical wall mount - indoor
Warranty Two years
Part numbers C12 - charge controller

Features & Options


Regulation method Standard - three-stage (bulk, absorption, and float), solid state, pulse width modulation
Field adjustable control setpoints Standard - removable knobs and calibrated scales
Setting protection Standard - knobs can be removed to prevent tampering
Testpoints Standard - provided for each setting
Automatic equalization Standard - every 30 days or after voltage reaches low voltage disconnect - can be disabled
External battery temperature compensation Optional - battery temperature sensor (BTS)
Short circuit protection Standard - fully electronically protected with auto reset and manual reset switch, protects both the loads and PV
array from damage from short circuits - a fuse for the battery is still advised to protect the battery wires
if located separately
Reverse polarity protection Standard - fully protected
Low voltage disconnect Standard - adjustable automatic or manual operation, manual reconnection includes warning flash of loads five
minutes before and a ten minute grace period

Regulatory Approvals
ETL Listed to UL 1741 No. 2 and CSA C22.2 No 14

Note: Specifications subject to change without notice.

34
Accessories

For use with multiple systems


TFB Fuse Block
The Xantrex Fuse Block has a DC rated class T fuse in a protective holder with
slide-off cover and is available in 110, 200, 300, and 400 A. We make two
types of this useful accessory, one with a wire clamp to accept bare copper wire,
and another with a post type terminal to accept cables with ring terminals.

For use with C Series Charge


Controllers
Battery Temperature Sensor
The BTS mounts on your battery and measures its temperature. It sends
precise information to the inverter/charger or charge controller, which
automatically adjusts charging voltage to ensure full battery charge,
regardless of the ambient temperature of your battery installation.
The BTS is standard on SW Inverters.

For use with multiple systems


TM500A Meter - Battery System Monitor
The TM500A provides easy to understand information. The fuel gauge style battery
meter makes keeping track of state-of charge virtually fool proof. The TM500A
comes with 15 m of cable, a Deltek 50 mV/500 A shunt, a prewired cable, and
a plug-in adapter board. Note: 48 V systems require the TM/48 adapter board.

For use with XW System


XW System Control Panel
The Xantrex™ XW System Control Panel (XW SCP) features a graphical, backlit LCD
display that provides system configuration and diagnostic information for devices
connected to the Xanbus™-enabled network. The XW SCP gives a single point of
control to setup and monitor an entire system, which may consist of multiple XW
Inverter/Chargers, XW Solar Charge Controllers and other components.

For use with XW System


XW Automatic Generator Start
The Xantrex™ XW Automatic Generator Start (XW AGS) will automatically activate a
generator to provide an XW Series Hybrid Inverter/Charger with power to recharge a
depleted battery bank or provide additional power for heavy loads. The XW AGS adds
intelligence to generator management, thereby eliminating time spent monitoring
batteries and inverter loads.

For use with XW System


XW Conduit Box
The XW Conduit Box, is a bare conduit box (no wires) that can be used to create
systems larger than two inverters, or to retrofit XW Inverters into existing systems
which may already have AC/DC disconnects.

35
Communications Gateway

Communication bridge for residential or small commercial remote monitoring systems

The Xantrex™ Communication The Gateway includes both built- Product Features
Gateway bridges the gap between a in Wi-Fi and Ethernet connectivity
Xantrex GT or XW System and the allowing for flexible and simple set up Can monitor a network consisting
system owner’s computer, making for wireless or wired connection to a of up to 20 single phase GT
it the central component for a router or direct to a PC. inverters and up to 8 XW devices
residential or small commercial (XW inverter(s), XW Charge
Controller(s), XW SCP, and XW AGS)
remote monitoring system. The Gateway logs and
Wi-Fi/Ethernet module with 10/100
transmits performance data
The Gateway logs performance Base-T or 802.11 b/g
System power production Can be configured to send energy
data directly from the Xantrex GT
Inverter specific power production and alarm reports via email
or XW System, and transmits it to
Lifetime energy production; Graphical interactive solar
the included Yahoo™ Widget based
daily, weekly, monthly energy monitoring software
monitoring software for a simple
production graphs Embedded web page for configuring
and graphically rich view of system
Inverter faults with date the Gateway and upgrading
performance. More than a data logger,
and time stamp inverter firmware
the Gateway offers a web page with
the ability to configure automated 16 megabytes of storage
email reports and fault status to the
user or installer.

36
Accessories

Electrical Specifications
Communication Physical layer 2, CAN
Communication protocol Xanbus™
Maximum Xanbus™ cable length 40 m
Maximum Ethernet cable length 60 m
Connectors 3 RJ-45 – 8 pins (2 Xanbus, 1 Ethernet)

Communication Specifications
Ethernet IEEE Std 802.3™-2005
Wireless 802.11.4b and 802.11.4g; WEP and WPA security
Channels 1-11 (US/Canada), 1-9 (Europe)

Mechanical Specifications
Dimensions (H x W x D) 11,2 x 19,0 x 45 cm
Height including antenna 24,9 cm
Weight 0,21 kg

Regulatory Compliance
North America EMC FCC part 15B class B
Industry Canada ICES-003 class B
Europe
Safety Low Voltage Directive 2006/95/EC EN60950-1:2001
EMC EMC Directive 2004/108/EC, EN55022 A2: 2003, EN55024 A2: 2003
Telecom R&TTE Directive 1999/5/EC, ETSI EN 301 489-1 ver. 1.6.1, ETSI EN 301 489-17 ver. 1.2.1

Note: Specifications subject to change without notice.

37
About Xantrex™

Xantrex Technology Inc. (www.xantrex.


com) is a world leader in the development,
manufacturing and marketing of advanced
power electronic products and systems for
the renewable, programmable, and mobile
power markets. The company’s products
convert and control raw electrical power
from any central, distributed, renewable,
or backup power source into high-quality
power required by electronic and electrical
equipment.

Xantrex is an ISO9001:2000 company and


its products are certified to UL, CSA or CE
standards. Xantrex is publicly listed on
the Toronto Stock Exchange (TSX:XTX).
Xantrex is headquartered in Vancouver,
Canada, with facilities in Arlington,
Livermore, San Diego, and Elkhart, United
States; Barcelona, Spain; Reading, England;
Berlin, Germany; and a joint venture in
Shanghai, China.

Xantrex Technology Inc.


Headquarters
8999 Nelson Way
Burnaby, British Columbia
Canada V5A 4B5
+1 604 422 8595 Phone
+1 604 420 1591 Fax

Xantrex Technology GmbH


Justus-von-Liebig-Str. 7
12489 Berlin - Germany
+49 30 6393 4242 Phone
+49 30 6392 4256 Fax

Xantrex Technology S.L.


Constitución 3,4o2a
08960 Sant Just Desvern
Barcelona - Spain
+34 93 470 5330 Phone
+34 93 473 6093 Fax

europesales@xantrex.com
europemarketing@xantrex.com

www.xantrex.com

©2008 Xantrex Technology Inc. All rights reserved. Xantrex, Trace, Prosine
and Smart choice for power are trademarks of Xantrex International,
registered in the U.S. and other countries.

Potrebbero piacerti anche