Thermal Spraying
Flame Spraying
Flame spraying guns are light and easy to manipulate. They burn
acetylene, propane or hydrogen with oxygen and the spray con-
sumable is in the form of a wire, cord or powder. An additional gas
jet is frequently incorporated to accelerate the particles towards the
workpiece.
Arc Spray
In this process, the heat source is an arc, struck between two wires,
which are both consumable. A jet of gas is used to project the molten
metal droplets towards the surface to be coated. This process is
190
Thermal Spraying 191
Powder
feed
Tungsten
electrode Gas
Electric
power
Spray Plasma
jet
capable of use on site, for example for spraying bridges with zinc or
aluminium.
Plasma Spray
This process uses a plasma to act as the heat source. The consum-
able is fed in as a powder and ejected at great speed towards the
workpiece, Fig. 21.1.
The greatest risk of fire in flame spraying and HVOF comes from the
use of highly flammable gases such as acetylene, propane, hydrogen,
etc. The storage of these gases should be in accordance with the
advice given in Chapter 4. In thermal spray, gas flows are large and
thus bulk supplies are more likely to be required. Advice should be
sought from the gas supplier in setting up a bulk store and delivery
system. For an HVOF system, a hazardous area classification will be
required which will define zones in which electrical equipment
must be to a standard to be safe in a potentially flammable atmos-
phere.49,172 The equipment should use approved hose and connec-
tors (see Chapter 10) and be provided with non-return valves and
flashback arrestors to protect the system against faults.
Many of the processes use consumables in the form of powders.
Many metal dusts, such as aluminium and titanium are a significant
fire and explosion hazard. It is essential therefore to remove metal
dust from spray booths or other confined spaces by adequate exhaust
ventilation. All ducting for ventilation and dust collecting plant
should be provided with blow-out panels and all equipment used
for ventilation, including motors fans and pipes should be electri-
cally earthed.
Thermal Spraying 193
Noise
Spraying guns, with the exception of flame spray guns, are noisy.
For instance, noise levels over 130 dB(A) have been recorded close
Thermal Spraying 195
Toxic hazards
Coating materials