Process Instrumentation

Every drop of water and every unit of energy counts

Environmental: Water

usa.siemens.com/pi
Instrumentation that puts you in control
Water is at the heart of life and economic activity. Measurement of critical process parameters is key for

process management and sustainability throughout all phases of the plant life cycle.

Siemens’ instrumentation offers you the technology A complete portfolio Siemens Process Instrumentation is part of
to put you in control. We not only give you accuracy We offer a complete portfolio of field instruments for the Siemens Environmental Portfolio
and reliability of measurement but also the reassur- flow, level, pressure and temperature measurement. This covers all Siemens products that are of extraordi-
ance of seamless integration from the planning and Our ­technology is designed to fit your individual nary benefit for the environment and for our custom-
engineering phase to operation and modernization. needs. We feel responsible for sustainable resource ers. Siemens flowmeters for water applications and
Siemens Totally Integrated Automation (TIA) ensures management and for efficient use of energy. valve positioners for compressed air applications are
that the data and alerts from your instrumentation certified products.
Besides inline flow measurement, clamp-on technol-
and process analytics devices are translated into early
ogy, ideal for retrofit installations, extends the stan- With Siemens you have the reassurance of best-in-
and effective action.
dard offering. Custody transfer-approved instruments class products and a partner who understands your
Faster and more efficient processes and guarantee accurate billing of water or heating/cooling industry. Discover more in this brochure and at:
operations in the water industry energy. Battery-operated meters and wireless tech­ www.usa.siemens.com/pi
To save time and money, processes need to be simpli- nology enable you to control stand-alone devices in
fied and run efficiently. Integrated engineering with remote or inaccessible locations, giving you reliable
COMOS and SIMATIC PCS 7, the Consultant DVD and information from the field as well as reduced cabling
the Industry Library from Siemens offer outstanding or other infrastructure costs.
solutions.

2
PIA Life Cycle Portal
The PIA Life Cycle Portal is a web-based application for easy and convenient product

selection and configuration.

How to get access


Advantages at a glance:
You can access the PIA Life Cycle Portal around-the-clock
• Convenient product selection support with
at usa.siemens.com/pia-portal. It offers you active
answers to typical questions
­support to find the best solution from the extensive
• A variety of selection possibilities: see
Siemens portfolio of sensors and process analytical
the sample processes and simply select from the
products. The portal can be used to see how different
recommended process instrumentation and
solutions can be put to use in process and factory
analytics products
automation.
• Project lists for an order enquiry can be quickly
You can choose between several selection access created
options to find the appropriate product solution for • Different possibilities for processing data and
your specific requirements: information
• No separate installation needed
• Direct access sends you straight to a specific config-
• Product selection for spare parts
uration if you know the product you are seeking.
• The latest product data and information for
• “Guided selection” lets you to select the appropriate
Siemens process instrumentation and analytics
application, technology or industry and specify the
measurement task based on the various relevant
­parameters for your particular application.
usa.siemens.com/pia-portal

Scan to
explore the
PIA Life
Cycle Portal

3
Product range
Level measurement

Radar

SITRANS Probe LR SITRANS LR250 SITRANS LR200 SITRANS LR560


Compact 2-wire loop-powered, 6 GHz pulse radar 2-wire loop-powered, 25 GHz pulse radar level 2-wire, 6 GHz pulse radar level transmitter for 2-wire, 78 GHz FMCW radar level transmitter for
­transmitter with polypropylene rod antenna for transmitter with a full range of antennas: continuous monitoring of liquids and slurries up continuous monitoring of solids in silos up to a
description

­level measurement up to a range of 20 m (65 ft). horn-/PVDF-/fully encapsulated flanged antenna to a range of 20 m (66 ft). range of 100 m (328 ft).
up to 20 m (66 ft).
Brief

• Uni-Construction polypropylene rod antenna standard • Smaller process connections and narrow beam • Graphical local user interface (LUI) makes operation • High-frequency technology ensures reliable opera-
• Easy installation and simple start-up allows installation anywhere on a vessel simple with plug-and-play setup using the intuitive tion in dusty and vaporous environments
• Patented Sonic Intelligence® signal processing • Short blanking distance Quick Start Wizard • Lens antenna, eliminating large parabolic or horn
• Extremely high signal-to-noise ratio • Process Intelligence® for advanced echo processing • LUI displays echo profiles for diagnostic support ­antennas, providing a narrow 4° beam angle. Highly
• Auto False-Echo Suppression of false echoes • Reliable and accurate for extremely high signal and • Process Intelligence signal processing for improved resistant to product buildup
• Measuring frequency: 5.8 GHz (6.3 GHz for low noise yields measurement reliability and Auto False-Echo • Integrated air purge connection as standard for
North America) • Full vessel capacity for high accuracy of low and high Suppression of fixed obstructions ­particularly difficult installations
• Programming using infrared Intrinsically Safe hand- levels • Programming using infrared Intrinsically Safe hand- • Communication: HART®, PROFIBUS PA,
held programmer, SIMATIC PDM or HART® handheld • Quick Start Wizard for easy configuration and opera- held programmer or over a network using SIMATIC ­FOUNDATION  Fieldbus
communicator tion in a few minutes PDM, Emerson AMS, or Field Device Tools, such as • Approvals: CSA, FM, FFC, C-Tick, IECEX, ATEX,
• Communication: HART® • Infrared handheld programming or over a network PACTware or Fieldcare via SITRANS DTM ­INMETRO, NEPSI
• Approvals: CSA, FM, C-Tick, ATEX using SIMATIC PDM via HART® or PROFIBUS PA • Communication: HART®, PROFIBUS PA
• Graphical local user interface displays, echo profiles • Approvals: ATEX, CSA/FM, NEPSI, C-TICK, INMETRO,
and benefits

and diagnostic information GOST


• Communication: HART®, PROFIBUS PA,
Features

­FOUNDATION  Fieldbus
• Approvals: ATEX, FM, CSA, C-Tick, INMETRO, IECEX, NEPSI

Level and volume measurement of aggressive liquids Continuous level and volume monitoring of aggressive Continuous level and volume monitoring of liquids and Continuous level monitoring of bulk solids and pow-
such as acids, lime and other slurries, alum, polymers, liquids and slurries in chemical storage and process slurries in anaerobic digesters, storage and process ders such as lime and activated carbon in water and
sodium hypochlorite <20 % etc. in chemical storage vessels, e.g. acids / alkalis, polymers, sodium hypo­ vessels in water and wastewater treatment plants. wastewater treatment plants for both batch and con-
applications

tanks in water and wastewater treatment plants. chlorite >20 %, chlorinates, buffer and mixing tanks tinuous operation.
Typical

in water and wastewater treatment plants.

 ore information:
M  ore information:
M  ore information:
M  ore information:
M
usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level

4
Guided Wave Radar Ultrasonic

SITRANS LG SITRANS LU150 SITRANS Probe LU HydroRanger 200


Guided wave radar series for liquids, solids, slurries, 2 wire, 4 to 20 mA loop powered transmitter is ideal 2-wire loop-powered ultrasonic transmitter for level, Versatile short to medium range up to 15 m (50 ft)
inventory, process control, aggressive materials and for liquids, slurries, and bulk materials in open or volume and flow monitoring of liquids. Continuous ­ultrasonic single- and multi-vessel controller for use
description

more. closed vessels to 5 m (16.4 ft).The transducer is ­level measurement up to 12 m (40 ft) range. in a wide range of environmental industries.
available in PVDF copolymer, making the device
Brief

suitable for use in a wide variety of applications.

• Versatile and reliable level measurement even with • Sonic Intelligence provided highly reliable • Integrated temperature compensation • Single- or dual-point level monitoring
aggressive vapors, high temperatures and pressure, measurement • ETFE or PVDF transducers for chemical compatibility • 6 relays standard
dust, steam, or material buildup • Easy to install and maintain • Patented Sonic Intelligence signal processing • Auto False-Echo Suppression for fixed obstruction
• Measures level, level interface and volume in a wide • Easy two-button programming • Extremely high signal-to-noise ratio avoidance
range of applications from material storage to bypass • PVDF transducer • Auto False-Echo Suppression for fixed obstruction • Anti-grease ring / tide mark buildup
pipes • Patented Sonic Intelligence echo processing avoidance • Differential amplifier transceiver for common mode
• Rod and cable lengths can be field adjusted to fit • Integral temperature compensation • Level to volume or level to flow conversion noise rejection and improved signal-to-noise ratio
your application • 4 to 20 mA output • Programming using infrared Intrinsically Safe • For up to 6 pumps, provides control, differential
• Quick Start Wizard for easy configuration and • General Purpose ­handheld programmer, SIMATIC PDM or HART® control and open-channel flow monitoring
operation in a few minutes ­Communicator • Communication: Modbus RTU via RS485, Smart Linx
• Communication: HART®, PROFIBUS PA Cards for PROFIBUS DP and SIMATIC PDM
• Approvals: ATEX, FM, CSA, INMETRO, IECEX, C-Tick • Easy to use HMI display with local four-button pro-
gramming, menu-driven parameters, and Wizard sup-
and benefits

port for key applications


• Approvals: FM, CSA, MCERTS
Features

Continuous level and volume monitoring of liquids Level in chemical small storage vessels, filter beds, Level, volume and flow monitoring in open channels, Level monitoring and control of wet wells, open-chan-
such as ammonia. Measurement in storage and process liquid storage vessels, in water and wastewater non-foaming chemical storage vessels, simple process nel flow monitoring of flumes / weirs. Bar screen con-
vessels in water and wastewater treatment plants. treatment plats vessels, filter beds, chlorine contact chambers, clari­ trol, level monitoring and control of screenings / sludge
applications

fiers, sumps, etc. in water and wastewater treatment storage hoppers, non-aggressive chemical storage,
Typical

plants. ­liquid storage, and dry solids storage tanks in water


and wastewater treatment plants.

More information:  ore information:


M  ore information:
M  ore information:
M
usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level

5
Level measurement

Ultrasonic Hydrostatic Pressure Point Level

SITRANS LUT400 Echomax Transducers SITRANS LH100 SITRANS LVL100 / 200


Compact, single-point, long-range ultrasonic controllers Range of ultrasonic transducers provides reliable 2-wire submersible pressure transmitter to measure Compact vibrating fork for liquid slurry point level
for continuous level, or volume measurement of liquids, continuous level measurement. Various models for a hydrostatic pressure, compact version. detection. Contactless electronic switch is especially
slurries, and solids, and high-accuracy monitoring of wide range of ­applications. suited for use in hazardous locations.
description

open channel flow. ±1 mm high accuracy in standard


operation.
Brief

Measuring range up to 60 m.

• Separated transceiver / transducer (Echomax) • Narrow beam angle from 6 to 12 ° • IP68 stainless steel housing (23,4 mm diameter) • Compact insertion length of 40 mm for tight
protects the electronics from extreme vibration • Chemically resistant PVDF copolymer e­ nclosure and with a piezoresistive sensor and ceramic diaphragm spaces
• High-frequency, non-contacting ultrasonic transducer is CMS rubber face • Converts the level-proportional hydrostatic pressure • Test function standard to confirm correct
free of electronic components and fully potted to • Fully submersible into a standardized signal 4 – 20 mA operation
provide long-term reliability • Integral temperature compensation • Accuracy ≦ 0.3 % • Fault monitoring for corrosion, loss of vibration, or
• Energy-saving algorithms for minimizing pump • Max. cable length of 365 m (1200 ft) • Measuring range: Standard 4, 5, 6, 10 and 20 m line break to the piezo drive Independent of
operation during high-cost energy periods • Choice of mounting brackets available for ease of (60 ft H2O), on request from 4 to 30 m (98 ft H2O) dielectric and other material conditions such as
• Sonic Intelligence is standard and is proven to provide installation • Communication: 4 – 20 mA vapors, gases, bubbles, foam
superior performance in difficult conditions • Approvals: ATEX, FM, CSA • Approvals: ATEX, ICEEx • Robust design with threaded piezo drive system to
• Communication: HART® prevent failure in aggressive applications
• Approvals: MCERTs, CSA, FM, UL, C-Tick • Approvals: EHEDG, 3 A, FDA, WHG, ATEX, FM, CSA,
SIL2, IECEx
and benefits
Features

Open-channel flow monitoring in sewers, combined Installation in tanks, vessels, hoppers, open space like in Level monitoring under harsh environmental High and low point level detection for liquid or
sewer overflow. Wet well level and pump control, storm dam or in open channel along with ultrasonics controllers conditions and for installation in tight spaces, e.g. slurries in various chemical and process water
applications

water tank and level monitoring in holding tanks / vessels like SITRANS LUT, HydroRanger 200 to form complete in deep narrow wells, very foamy sumps & wet wells, storage tanks and sumps in water and wastewater
in water and wastewater treatment plants. ultrasonics level or flow measurement system. grease traps, irrigation canals, dams and reservoirs in treatment plants.
Typical

water and wastewater treatment processes.

 ore information:
M  ore information:
M  ore information:
M  ore information:
M
usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level usa.siemens.com/level

6
Flow measurement

Electromagnetic

SITRANS LVS100 / 200 Pointek CLS100 / 200 SITRANS F M MAG 1100 SITRANS F M MAG 3100
Vibrating fork for dry bulk solids point level Compact 2-wire inverse frequency shift capacitance switch for Electromagnetic flow sensor with stainless steel Electromagnetic flow sensor in a rugged, fully-welded
detection up to 20 m (65 ft). ­level detection in constricted spaces for interfaces, solids, liquids, housing for chemical dosing. design, can be upgraded to IP68 on site to be buried.
slurries and foam.
description
Brief

• High or low level alarm • Tip-sensitive switch, unaffected by conductive or non-conductive • Compact wafer design meets ANSI, EN 1092 and • Wide pressure range flanges: ANSI
• Compact design buildup DIN flange standards Class 150 / 300, AWWA, PN 6 to PN 100, , AS 2129 / AS
• Top, side, angle mount • Potted construction protects signal circuit from shock, vibration, • Corrosion-resistant AISI 316 L stainless steel 4087 or JIS
• Rotatable enclosure humidity and / or condensation ­sensor housing • Wide range of electrode and liner materials i­ncluding
• Replaceable electronics • High chemical resistance • Highly resistant liner and electrodes for EPDM (drinking water approved)
• Interface model with detection of solids • Level detection independent of tank or pipe grounding ­aggressive media • Fully-welded construction that suits the toughest
in liquids • Insensitive to product buildup due to high-frequency oscillation • Medium temperature rating up to + 200 °C applications and environments
• Best-in-industry lowest density measurement • High sensitivity allows installation in a wide range of liquids, solids, (+ 390 °F) • Designed for patented in-situ verification of
below 5 g / l slurries or interface applications • IP67 / NEMA 4X / 6 enclosure rating the whole flowmeter using the SENSORPROM
• Independent of dielectric and other material • Integral LCD display allows for easy setup to configure detection • Designed for patented in-situ verification of ­fingerprint
conditions such as vapors threshold, even under the most demanding process conditions the whole flowmeter using the SENSORPROM • Easy commissioning, SENSORPROM unit automatically
• Unaffected by external vibrations • Extended rod, cable and sanitary versions available ­fingerprint uploads calibration values and settings
• Replaceable electronics • Standard version: 3 LED indicators for adjustment control, • Easy commissioning, SENSORPROM unit • Approvals: Drinking water approvals including NSF/
• Short fork option for short insertion lengths output status and power automatically uploads calibration values and ANSI Standard 61, and certificates according to
and benefits

• Remote electronics option • Digital version: integral LCD display settings national and international standards FM, CSA, ATEX,
• Communication: 4 – 20 mA • Communication: PROFIBUS PA • Approvals: FM CL1 Div. 2, ATEX 2G D sensor IEC Ex
Features

• Approvals: FM, CSA, ATEX, C-Tick • Approvals: CSA, FM, ATEX, C-Tick, WHG, Pattern approval china Ex de ia IIB T3 - T6

High and low point level detection for bulk High and low point level detection for clean & contaminated Volume flow measurement for chemical dosing Volume flow measurement for water, salt water and all
solids storage tanks such as lime, activated ­liquids and slurries holding tanks and sumps in water and in water treatment processes, with a minimum liquids and chemicals with a minimum
applications

carbon, dry chlorine powder, etc. in water ­wastewater treatment plants. Overspill and pump protection electrical conductivity of 5 μS / cm. electrical conductivity of 5 μS / cm.
and wastewater treatment plants. in wet wells.
Typical

More information:  ore information:


M  ore information:
M  ore information:
M
usa.siemens.com/level usa.siemens.com/level usa.siemens.com/mag usa.siemens.com/mag

7
Flow measurement

Electromagnetics

SITRANS F M MAG 5100 W SITRANS F M MAG 5000 / 6000 / 6000 I SITRANS F M Verificator SITRANS F M MAG 8000 / CT / Irrigation
Electromagnetic flow sensor in a rugged, fully-welded Electromagnetic flow transmitter for flow and The Verificator provides the ability to confirm accurate Battery-operated electromagnetic water meter for
design, can be upgraded to IP68 on site to be buried volume measurement in combination with any performance of your Siemens Magnetic Flow Meter. stand-alone water applications, optional built-in
description

and flooded. Designed for the water and wastewater electromagnetic flow sensor. Can be used with sensors The Verificator works with the MAG5000/6000 wireless communication module. IP68 designs allow
industry. including MAG1100, MAG3100 and MAG5100W. transmitters and MAG 1100 & 1100F, MAG3100 & the sensor to be buried and flooded.
Brief

3100P, and MAG5100W sensors.

• Hard rubber lining guarantees consistent accuracy • Superior signal resolution for optimum turndown ratio • In-situ check of performance without interrupting • Compact or remote solution
throughout the entire pressure and temperature • Automatic reading of SENSORPROM data for easy the flow meter installation • Flexible power supply – internal or external battery
range commissioning • Verification of the sensor, the transmitter and the pack or line power supply with battery backup.
• Integrated Hastelloy C grounding and measuring • User-configurable operation menu with password interconnecting cable when the transmitter is 6 years battery life in typical revenue applications
electrodes protection remotely mounted • Bidirectional measurement
• Increased low flow accuracy for water leak detection • Flow rate in a wide range of units • Fully automated – no manual set up or data input – • Data logger with up to 26 months of recording and
• Built-in length according to ISO 13359 • Totalizer for forward, reverse and net flow plus with predefined factory accept levels consumption profile
• Designed for patented in-situ verification of the ­additional information • No expensive removal or installation costs • Alarm: Current consumption too high or too low
whole flowmeter using the SENSORPROM fingerprint • Multiple functional outputs for process control, • Full verification report to confirm meter performance • Advanced statistics and diagnostics
• Easy commissioning, SENSORPROM unit minimum configuration with analogue, according to quality standard ISO 9001 and • 0xD of straight pipe required upstream and
automatically uploads calibration values and settings pulse / frequency and relay output (status, flow management standard ISO 14001 suitable for third downstream from the sensor
• 0xD of straight pipe required upstream and direction, limits) party agencies looking for confirmation that the • Communication: Wired Modbus, IrDA, Radio
downstream from the sensor • Comprehensive self-diagnostic for error indication meter has been tested and confirmed accurate to its GSM / GPRS
and benefits

• Approvals: according to regional and national and error logging original specifications. • Approvals: CT, NSF/ANSI Standard 61, MI 001 (cold
standards. CSA Class I, Div 2 and FM Class I, Div 2 • Compact or remote version water) OIML R49, MCERTS, WRAS, KTW, DVGW 270,
Features

• Communication: HART®, Modbus RTU, ACS, Belgaqua, NMI 10 for SITRANS F M


­PROFIBUS PA / DP, DeviceNet, FF MAG 8000 Irrigation

For all water applications such as groundwater, Transmitter for all electrically conductive liquids and The Verificator is routinely used to confirm the performance Water distribution network: Optimize water supply &
drinking water, cooling water, wastewater, sewage slurries. The MAG5000 and MAG6000 are compatible of the Siemens Magmeter and Transmitter without the need reduce leakage. Revenue metering: CT approved meter
and sludge applications. Installation in water networks with the Siemens Verificator. The rugged die-cast to remove the Magmeter from the process line. The for accurate billing. Irrigation: Long-term performance,
for leak detection and billing. aluminum housing of the SITRANS F M MAG 6000 l Verification process can extend or eliminate the need to maintenance-free fair billing.
applications

provides exceptional protection, even in the most have the flow meter calibrated by either the manufacturer
Typical

rugged environment, including versions suitable for or a third party agency.


FM CL1 Div 1 installations.

 ore information:
M  ore information:
M  ore information:
M  ore information:
M
usa.siemens.com/mag usa.siemens.com/mag usa.siemens.com/mag usa.siemens.com/mag

8
Ultrasonic

SITRANS F US SONOKIT SITRANS Sono 3100/3300 SITRANS FUS1010 SITRANS FST020


Simple and accurate alternative to traditional In-line Ultrasonic flow measurement for flow and Advanced and highly accurate clamp-on Basic clamp-on ultrasonic flowmeter, performing basic
flowmeters because it can be retrofitted onto existing volume measurement of water and waste water. ultrasonic flowmeter allows simultaneous measurement tasks. Non-intrusive metering, easy
description

pipelines. IP68 version for burial and flooding measurement of up to 4 independent pipes and ­installation and maintenance.
applications. It includes the FUS060 or FUS080 bidirectional flow operation.
Brief

transmitter.

• Cost-effective solution – contains all necessary • Line sizes ranging from 2” to 24” • Operation in Wide-Beam transit-time or Doppler • No process shutdown for installation
components for retrofitting • 2-path measuring principle for optimum accuracy mode • Minimal maintenance: external sensors do not
• Easy to install in pipeline sizes DN 100 to DN 4000 • 4-path sensor technology available on request • Easy installation; external sensors, require periodic cleaning
(4" to 160") – without process shutdown or flow • Sensors can be replaced under pressure (3100) no need to cut pipe or stop flow • No moving parts to wear or foul
interruption. • Robust design for industrial applications • No pressure drop or energy loss • No pressure drop or energy loss
• High accuracy – the bigger the pipe, the more • No pressure drop • Wide turndown ratio • Compact, integral design reduces installation cost
accurate the result • Dynamic range Qi:Qs up to 1:400 • Choice of single channel or dual channel / dual path, • Wide-Beam technology ensures high performance
• Solid construction and no moving parts for a 100 % • Communication: Profibus PA, HART, analog outputs with doppler capability. Four channel / four beam • Zeromatic Path eliminates zero drift
maintenance and obstruction free flowmetering optional • Bidirectional flow operation
• Automatic calculation of the calibration factor when • Zeromatic Path automatically sets zero without • 1 MByte data logger with both site & data logger storage
pipe geometry data are entered in the transmitter stopping flow and reduces zero drift, even at low • Approvals: UL, ULc, C-Tick
• Battery-powered option with FUS080 flow • Communication: BACnet MSTP, Modbus RTU, VT100,
• Communication: HART®; PROFIBUS PA, IrDA optical • 1 MByte data logger with logger storage RS232
and benefits

eye via Modbus RTU (FUS080 only) • Approvals: INMETRO, CSA, FM, ATEX, ­
• Approvals: ATEX with FUS060 C-Tick, HART®, BacNET MSTP/BACNet IP, Modbus RTU/
Features

TCPIP, Ethernet IP
• Communication: RS232

Flowmeter for retrofit of all the following applications: Raw water intake for water treatment plants, ground Water leak detection and water monitoring Water leak detection and water monitoring
Raw water intake for water treatment plants, water water, drinking water, treated wastewater. applications, wastewater applications, wastewater
distribution systems, irrigation systems, hydro power Influent and effluent, processed sewage and sludge Influent and effluent, processed sewage and sludge
stations, district heating and cooling plants, cooling
applications

systems, sewage treatment plants.


Typical

More information:  ore information:


M  ore information:
M  ore information:
M
usa.siemens.com/flow usa.siemens.com/flow usa.siemens.com/clamp usa.siemens.com/clamp

9
Flow measurement Pressure

Ultrasonic clamp-on Vortex Pressure measurement

SITRANS FUP1010 SITRANS FX300 SITRANS P 200 / 210 / 220 SITRANS P300


SITRANS FUP1010 clamp-on non-intrusive ultrasonic Vortex flowmeters provide accurate volumetric and Compact single-range transmitters for absolute and gauge Digital pressure transmitter for gauge,
flow transmitter offers maximum versatility plus battery mass flow measurement of steam, gases and liquids, pressure. Measurement of process pressure, absolute pressure absolute pressure and level measurement.
power for portable field use. It can operate in either with integrated temperature and pressure and hydrostatic pressure.
WideBeam transit time or reflexor (Doppler) mode, compensation.
description

making it suitable for virtually any liquid, even those


with
Brief

high aeration or suspended solids.

• Operation in Wide-Beam transit-time or Doppler mode • Compact or remote design (max. 15 m) • Piezoresistive measuring cell with ­ceramic diaphragm (P200) • Piezoresistive measuring cell, oil-filled
• No process shutdown for installation • Single or dual transmitter version or SS diaphragm (P210 / 220) • Measuring range from 10 mbar to 400 bar
• No pressure drop or energy loss • Flow, pressure and temperature reading at one • Fixed-range transmitter • High measuring accuracy up to 0.075 %
• Battery-Powered up to 7 hours single point • Measuring range starting at 100 mbar up to 600 bar • Configuration through push buttons and
• IP67 Weatherproof enclosure • Accuracy: ± 0.75 % … 2.5 % (depending on media) • For aggressive and non-aggressive gases, vapors and liquids • LCD, HART® or PROFIBUS PA
• Impact Resistant • Fully-welded stainless steel construction; high • High measuring accuracy < 0.25 % • Ingress protection up to IP68
• Single or Dual channel/path configurations available corrosion, pressure and temperature resistance • Rugged stainless steel enclosure • Front flush mounted membrane and
• 1 MByte data logger with logger storage • Isolation valve to protect pressure sensor during • Compact design housing made of stainless steel
• FUP1010 Water check metering kit for water/waste pressure / leak testing in the pipe • EPDM gaskets for drinking water • FDA-compliant filling oils
water available • Communication: HART® • Ingress protection up to Fully IP67 • Excellent surface quality (Ra value ≤ 0.8 μm
• Approvals: FM, ATEX, IEC Ex • Available in explosion-protected design according to ATEX for process wetted parts)
• Communication: 0–20 mA, HART®,
PROFIBUS PA or FF
• Approvals: EHEDG, 3 A
and benefits
Features

Potable water, chemicals, Influent and effluent, Consumption measurement in compressed air Compact and economical pressure measurement in clean Pressure measurement in raw water intake,
sludges, check measurement, process control, and systems and other industrial gases or steam water and waste water process. sludge line, grit wash water, methane gas,
applications

water leak detection. installations. chemical storage, industrial utility


applications, desalination and irrigation.
Typical

 ore information:
M  ore information:
M  ore information:
M More information:
usa.siemens.com/clamp usa.siemens.com/flow usa.siemens.com/pressure usa.siemens.com/pressure

10
Positioner Temperature

Temperature measurement

SITRANS P DS III P310 and P410 SIPART PS2 SITRANS TS sensors SITRANS TH, TR, TF transmitters
Advanced digital pressure transmitter for Pneumatic, digital valve positioner with unique low SITRANS TS temperature sensors for a wide range Portfolio of temperature transmitters for head, rail or field mounting,
gauge, absolute and differential pressure, air bleed design. of temperature applications. for connection to many different thermocouples, resistance
level and flow measurement. Integral square thermometers, as well as mV and resistance sensors.
root extractor for venturi flow.
description
Brief

• Piezoresistive measuring cell, oil-filled • Almost zero air bleed at steady state (HYPERLINK SITRANS TS500 SITRANS TH
• Measuring range from 0.01 psi to 10153 psi "http://www.usa.siemens.com/cost-of-air" Cost of • Modular system of tubular or barstock • Installation in connection head Form B
• High measuring accuracy up to 0.065% Air Calculator) thermowell, extension, connection head with • Galvanic insulation and fault detection
• High long-term stability up to 0.125 % per 5 • Controls any style of pneumatic actuator optional transmitter and display • EMI-resistant transmission of the signal
years • Advanced valve diagnostics included, just turn • Replaceable measuring insert makes it possible SITRANS TR/TW
• Separate replacement of measuring cell and them on to conduct maintenance work even without • 2-wire or 4-wire rail-mount
electronics without recalibration • Pushbuttons and display included, no additional shutting down operations. SITRANS TF
• Configuration through push buttons / LCD setup equipment required • Available in explosion-protected design • Die-cast aluminum or stainless steel housing
• Ingress protection up to IP68 • Over 300+ mounting kit solutions according to ATEX and IECEx • LCD display
• Extensive diagnostics and simulation • Optional Remote Mount, Wear-Free Position • Available in explosion-protected design according to ATEX
functions with PDM Detection, Integral High Flow (Cv) and IECEx
• Communication: 0–20 mA, HART®, • 4–20 mA, HART®, PROFIBUS PA, ­FOUNDATION Fieldbus,
PROFIBUS PA, FOUNDATION Fieldbus WirelessHART®
• Approvals: FM, SIL, CSA, IECEx, ATEX, NSF/
and benefits

ANSI 61 NSF/, ANSI 372


Features

Various pressure, level and flow measurement For all pneumatic control valve and on/off valve For all temperature applications, e.g. surfaces, For all temperature applications.
in water/wastewater plants, chemical storage applications. bearings, machinery, equipment, in vessels and
applications

and other utility installations. D


­ esalination & pipes.
irrigation installations.
Typical

More information:  ore information:


M  ore information:
M  ore information:
M
usa.siemens.com/pressure usa.siemens.com/pressure usa.siemens.com/temperature usa.siemens.com/temperature

11
Weighing Communication and software

Weighfeeders Belt scales Remote displays

SITRANS weighfeeders Milltronics MSI SITRANS RD100 / 200 SITRANS RD300 SITRANS RD500
SITRANS WW100 and WW200 weighfeeders provide The Milltronics MSI belt scale has more approvals than SITRANS RD100 is a loop-powered Dual-line, panel mount, Remote data manager providing
continuous feed rate control of lime for slaking in any other belt scale on the market with general, food, ­remote display, and RD200 is a remote digital display for ­remote monitoring through data
water purification processes. With dust-tight enclosure hazardous and trade approvals. universal remote digital display for process instrumentation for ­logging, web access and alarming
description

options and high temperature belt these proven Probe LU, Probe LR, SITRANS P MPS to Probe LU, Probe LR, SITRANS P for instrumentation.
weighfeeders ensure uninterrupted control for install at or in areas with easier MPS to install at or in areas
Brief

­optimum process quality. access. with easier access.

• ± 0.25 – 0.5 % accuracy over a 10 – 100 % capacity • ± 0.5 % accuracy over a 20 – 100 % capacity rate range • Make measurement data visible and • Easy-to-read, dual-line dis- • Integrated web and ftp server, email
rate range • Single idler compact design for easy retrofit or new accessible from a remote location. play with eight brightness and sms for alarming, and up to 2 GB
• Compact design for easy retrofit or new installations i­nstallations • Compatible with all types of field levels for data logging of instrumentation
• Painted mild steel, or stainless steel options • Painted mild steel, galvanized or stainless steel options ­instruments in varying process • Flexible outputs with up to • Simple access to data remotely installed
• Dust-tight easy-open enclosure options • Proven triple-beam parallelogram stainless steel ­conditions eight relays and eight digital instrumentation
• Self-cleaning belt support pans or bars load cells • Easy to set up and program I / O for process control • Collects and sends sensor data to
• Up to 100 tph flow rate capacity • Up to 12,000 tph flow rate capacity • SITRANS RD200 includes freely alarming logistics systems providing up-to-
• Complete process control with Milltronics BW500 • Complete process control with Milltronics BW500 available logging and monitoring date, timely, and accurate
­integrator ­integrator software, allowing multiple displays information. Ethernet or Modem
and benefits

• Communication (BW500): 4 – 20 mA, Modbus ASCII, • Communication (BW500): 4 – 20 mA, Modbus ASCII, to be monitored from one PC (PSTN / GSM / GPRS) carries data to
Modbus RTU, Modbus TCP / IP, Ethernet / IP, Modbus RTU, Modbus TCP / IP, Ethernet / IP, • SITRANS RD200 has optional large your desktop without the need of
Features

­PROFINET, PROFIBUS DP, DeviceNet ­PROFINET, PROFIBUS DP, DeviceNet display with 35 mm (1.2") high LED ­additional software.
• Approvals: Hazardous rated component options available • Approvals: CSA, FM, Atex, IEC Ex, GOST-R Ex

Lime slaking. Solids sludge transport on conveyors. Remote process monitoring. Remote process monitoring. Remote monitoring of inventory
levels, process and environmental
applications, provides web access to
most types of field instrumentation,
applications

including flow, level, pressure,


Typical

temperature measurement and


weighing.

 ore information:
M  ore information:
M  ore information:
M  ore information:
M  ore information:
M
usa.siemens.com/weighing usa.siemens.com/weighing usa.siemens.com/pi usa.siemens.com/pi usa.siemens.com/pi

12
Service & Support Software

Service & Support SIMATIC PDM SITRANS Library


Siemens Process Instrumentation provides a complete line of service and Universal, non-proprietary tool for the configuration, parameterization, The SITRANS Library consists of function blocks, block icons and faceplates
support to keep your operation running with superior performance. commissioning, diagnostics and maintenance of intelligent field devices for a growing number of field instruments out of the families SITRANS
(sensors and actuators) and field components (remote I / Os, multiplexers, and SIPART. Target systems are SIMATIC PCS 7 and SIMATIC PLCs in
description

control room devices, compact controllers). ­parallel with SIMATIC WinCC and panels. Automation solutions can be
­implemented just by using already existing features and diagnostics
Brief

­information available in the instruments.

• Local support • Available as point-to-point or as an integrated part of SIMATIC S7 / PCS 7 Devices supported:
• Start-up • Allows the user to access any instrument or field device • SITRANS F M MAG 6000
• Calibration • Permits the plant to back up parameters as well as access programming • SITRANS LUT400
• Troubleshooting information or diagnose potential problems from a handheld, a field PC • SIPART PS2 with PROFIBUS PA and 4–20 mA / HART® interface
• Training or a workstation connected to the central control system
Customer advantages are:
• Same look and feel like standards in SIMATIC PCS 7
• No additional training for operators
• Usage of features in field devices without additional cost:
and benefits

customers use what they already have paid for


Features

All field applications, start-up and services Configuration, parameterization, commissioning, diagnostics and • Innovative dosing using the dosing feature of
maintenance of intelligent field devices and field components. SITRANS F M MAG 6000 at lower cost
• Fast and flexible operation of valves with SIPART PS2 with a
much higher degree of transparency
applications
Typical

More information:  ore information:


M  ore information:
M
usa.siemens.com/pisupport usa.siemens.com/simatic-pdm usa.siemens.com/library

13
Totally ERP – Enterprise Resource Planning

Integrated
PLM – Product Lifecycle Management

Automation
• Product Design
• Production Planning and Simulation
• Data Management

Products from the controller level to the Management Level MES – Manufacturing Execution Systems
field level SIMATIC IT

With Totally Integrated Automation (TIA),


Siemens is the only provider of an end-to-end
integrated portfolio of products and systems
for the automation of the entire production Operations Level SIMATIC PCS 7 Maintenance / Asset Engineering
Operation System Management Station
workflow.
Totally Integrated Automation reduces the
complexity of the automation solution and
enables what really counts: the practical com- TIA Portal
bination of optimally coordinated individual
components – without interface problems.
Control Level
Totally Integrated Automation integrates
not only the p
­ roduction process but all parts SIMATIC PCS 7
Automation
SINUMERIK
Computer Numeric Control
SIMOTION
Motion Control
SIMATIC NET
Industrial
of the company – from the field level to the Systems Communication

management level. The result: a perfectly


coordinated overall concept that enables
higher productivity.

Field Level

PROFIBUS PA

Process Instrumentation SIMATIC Ident


Industrial Identification

Totally HART
Integrated
Automation
Example: SIMATIC PCS 7. The innovative process
IO-Link
control system offers numerous options for
connecting I / Os as well as for sending and receiving
process signals via sensors and actuators.

14
Process
Instrumentation
Training
Plant Engineering With Siemens Process Instrumentation you
COMOS
are in complete control of your water and
wastewater operations. That’s why it’s so
Ethernet important that your team be fully trained to
maintain and handle any situation that may
Energy
Management
SIMATIC WinCC
SCADA System
arise. Our comprehensive training classes are
led by field-proven and experienced instructors
who combine extensive application and
Industrial Ethernet instrumentation knowledge with many years
of training experience.
Our 3 day, comprehensive, hands on water
and wastewater class provides students with
the technical knowledge required to specify,
SIMATIC Controllers SIMATIC HMI SIRIUS Industrial Controls
apply, install, and maintain process instruments
Modular / PC-based Human Machine Interface utilized in both drinking water and waste water
applications.
Want to learn even more? Our technology
focused courses delve deeper into a wide
array of specific topics, including pressure,
temperature, level, valve positioners, loop
controllers, flow, weighing and industrial
communications.
Classes are offered throughout the year at
PROFINET
various locations or through our mobile training
Industrial Ethernet platform we can bring the class right to you!
PROFIBUS
For more information please send an email to
SIMATIC Distributed I / O SINAMICS Drive Systems Low-Voltage Distribution AS-Interface
piatraining.industry@siemens.com, or call
KNX GAMMA instabus
1-800-365-8766, Prompt 7.
Totally
Integrated
Power

SIMOTICS Motors

15
Follow us on:
www.fb.com/siemensII
www.twitter.com/SiemensII
www.youtube.com/user/Siemens
https://blogs.siemens.com/measuringsuccess

usa.siemens.com/pi

More information:
info.us@siemens.com

Siemens Industry, Inc. Subject to change without prior notice Subject to changes and errors. The information given in this document only contains
100 Technology Drive Order No.: PIBR-0A290-0516 general descriptions and/or performance features which may not always specifically
Alpharetta, GA 30005 reflect those described, or which may undergo modification in the course of further
All rights reserved
development of the products. The requested performance features are binding only
Printed in USA when they are expressly agreed upon in the concluded contract.
1-800-365-8766
info.us@siemens.com © 2016 Siemens Industry, Inc.