Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
In case of material upgrade (65 or 70), the calculated thickness is still correct as mechanical properties are improved.
Design Conditions
Fluid Gaz à condensats
Type
Dimensions Ø 24'' - 600 Lbs
Operating Pressure 8 MPa
Max. Operating Temperature 60 °C
Min. Operating Temperature 5 °C
Nozzle on Header
1
WN Ø2" 11,07 mm Pad 8 mm x #N/A
Material
2/7
PROCESS SYSTEMS/ALLIA Note de calcul projet ref : 40390
Z.A. Les Landes COSIDER 08/02/2019
49481 VERRIERES EN ANJOU (France) RAMPE DE COMPTAGE 24"-BENI SAF Rév.A
Design Conditions
Design pressure P 8 MPa
Design temperature 60 °C
Corrosion Allowance 0 mm
Test pressure Pe 12 MPa
2/7
PROCESS SYSTEMS/ALLIA Note de calcul projet ref : 40390
Z.A. Les Landes COSIDER 08/02/2019
49481 VERRIERES EN ANJOU (France) RAMPE DE COMPTAGE 24"-BENI SAF Rév.A
ASME Code for Pressure Piping, B31.8-2016 The concentric or eccentric reducer will be considered as a conical section and designed according
to ASME VIII Div.1 (§ UG32) with formula below :
The required minimal wall thickness is calculted as follows : 𝑃𝐷
t = 2 cos α (𝑆𝐸 −0.6𝑃)
2𝑆𝑡 𝑃𝐷 - D = nominal outside diameter of pipe, mm.
Formula : P = 𝐹𝐸𝑇 became t = with :
𝐷 2𝑆𝐹𝐸𝑇 - E = joint efficiency
- α = one‐half of the included (apex) angle of the cone at the centerline of the head, degree.
- D = nominal outside diameter of pipe, mm. - P = design pressure, MPa.
- E = longitudinal joint factor obtained from Table 841.1.7-1. - S = specified minimum yield strength, MPa.
- F = design factor obtained from Table 841.1.6-1.
- P = design pressure, MPa. ASME Code for Pressure Piping, B31.8-2016
- S = specified minimum yield strength, MPa. 𝑃𝐷
Hoop Stress Formula : t = 2𝑡
- T = temperature derating factor obtained from Table 841.1.8-1.
- t = nominal wall thickness, mm when we search "P" and t = minimal wall - D = nominal outside diameter of pipe, mm.
thickness when we search "t". - P = design pressure, MPa.
Design Pressure
Minimmum Yeld Stress - S in MPa (SMYS x F x T) 298,08 Mpa 298,08 Mpa 298,80 Mpa
Required minimal wall thickness calculted 8,19 mm #N/A #N/A #N/A
Corrosion allowance 0,00 mm 0,00 mm 0,00 mm 0,00 mm
Allowance 1,88 mm 0,00 mm 0,00 mm 0,00 mm
Minimal wall thickness with B31.8 Code 10,07 mm #N/A #N/A #N/A
Hoop Stress at design pressure SH in MPa 162,67 Mpa 133,63 Mpa 153,65 Mpa 133,63 Mpa
Ratio 39,29% 32,28% 37,02% 32,20%
Test Pressure
Minimmum Yeld Stress - S in MPa (SMYS) 414 414 415
Required minimal wall thickness calculted 8,84 mm #N/A #N/A #N/A
Corrosion allowance 0,00 mm 0,00 mm 0,00 mm 0,00 mm
Allowance 1,88 mm 0,00 mm 0,00 mm 0,00 mm
Minimal wall thickness with B31.8 Code 10,72 mm #N/A #N/A #N/A
Hoop Stress at Test pressure SH in MPa 244,00 Mpa 200,44 Mpa 230,48 Mpa 200,44 Mpa
Ratio 58,94% 48,42% 55,54% 48,30%
2/7
PROCESS SYSTEMS/ALLIA Note de calcul projet ref : 40390
Z.A. Les Landes COSIDER 08/02/2019
49481 VERRIERES EN ANJOU (France) RAMPE DE COMPTAGE 24"-BENI SAF Rév.A
Deisgn in accordance of Algeria Rules "Règles de sécurite pour les canalisations de transport de Gaz Combustibles_Septembre 1991"
Design zone acc. (Article 4) Zone Ia
Rampe Major Reducer
24'' 0 24'' 0
Yeld strength factor (Article 6) - X.E in MPa ( 60 % E ) 248,4 248,4 249
Tensile strength factor (Article 6) - Y.R in MPa (36 % R ) 186,12 186,12 185,4
Minimum (XE ; YR) (Article 6) - t in MPa 186,12 186,12 185,4
Règles de sécurite pour les canalisations de transport de Gaz Combustibles_Septembre 1991 The concentric or eccentric reducer will be considered as a conical section and
The required minimal wall thickness is calculted as follows : designed according to ASME VIII Div.1 (§ UG32) with formula below :
2𝑡𝑒 𝑃𝐶 𝐷 𝑃𝐷
Formula : PC = became e = with : t=
𝐷 2𝑡 2 cos α (𝑆𝐸 −0.6𝑃)
Design Pressure
Required minimal wall thickness calculted 13,11 mm #N/A #N/A #N/A
Corrosion allowance 0,00 mm 0,00 mm 0,00 mm 0,00 mm
Allowance 1,88 mm #N/A 1,59 mm #N/A
Minimal wall thickness with Règles de sécurite Algérie 14,99 mm #N/A #N/A #N/A
Test Pressure
Required minimal wall thickness calculted 9,82 mm #N/A #N/A #N/A
Corrosion allowance 0,00 mm 0,00 mm 0,00 mm 0,00 mm
Allowance 1,88 mm #N/A 1,59 mm #N/A
Minimal wall thickness with Règles de sécurite Algérie 11,70 mm #N/A #N/A #N/A
2/7