Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
About
A vision, by three professionals having a collective experience of more than 50 Quality Systems and Procedures. Special emphasis is given to all these. In 2009
years, of providing Best of Art, Reliable and Technologically Advance Protection Procom qualified for ISO-9001 certification.
(Pro), Control (Co) and Metering (M) gave birth to MRM Procom Pvt. Ltd. The
company designs and manufactures micro-processors/DSP based sophisticated MRM Procom lays very heavy emphasis on the production and testing
systems for protection, controls and measurements of Power Generation and equipment's. We believe that the chain is as strong as its weakest link and hence
Distribution. the production and testing equipment's are procured only from well renowned
manufactures. All the testing equipment is calibrated at regular intervals. The
In year 2005 this vision was translated into reality when MRM Procom Pvt. Ltd. production is equipped to handle both through hole and SMD technology and is
was incorporated/ registered by the Indian Companies Act and started its capable of handling both leaded and lead free components. We have installed Fully
operation at a 1000 square feet rented premises in Okhla Industrial Estate. Automatic Pick and Place Machine from Juki Japan, Stencil printer from Akra,
Germany, Reflow of EMS and Wave Soldering machine with Dual wave from EMS.
Initial couple of years were utilized by the company in trying to carve a name of it, The calibration and testing facilities are also up to date and consists of State of the
as well as, have an in depth understanding of the generator market. Art Calibration with reference meter from ZERA and simulator and voltage &
current source from Calmet, Multi-Meters from Fluke, oscilloscopes from
By 2008 the company was well established and had earned the trust of the Tektronix, LCR Meter from HP. An in-house EMI & EMC pre-compliance facility is
customers. The brand PROCOM® was an accepted trade mark. Customer also available.
acceptability translated into orders demanding more human, machinery and
working area resources. The company moved into a new premise of 3000 sqft. MRM PROCOM is now recognized and approved for its reliable product and
and in 2009 another premises of 2500 sqft. was hired to enhance the production service by many govt, sector and renowned Private sectors e.g. Havells, Greaves
capacity. In 2010 Haryana Government allotted one acre of Industrial Plot and Cotton Mahindra & Mahindra, Ashok Leyland, DGS&D, Escorts, Eicher, Sonalika,
construction of State of the Art Manufacturing Plant having a covered area of Mitsubishi, Cummins, Airtel, Vodafone, Emerson, BSNL etc.
around 40,000 sqft. was started. The company shifted to its new premises, at
Faridabad in Nov. 2012.
MRM Procom always believed that the quality of its product depends upon the
quality of Man Power, Production Equipment, coupled with strict adherence to
02
DIGITAL PANEL METER
ACE Introduction Technical Specification
ACE series meters are compact digital power meter, equipped with customized 6 Accuracy : Class 1.0 IEC 62053 - 21/ (Optional
digit, 3 row alphanumeric display. Four navigator keys & alphanumeric digits 0.5;0.2 IEC 62053-22)
simplifies display & configuration of meter. ACE series are available with accuracy Input Voltage : Vr, Vy, Vb, Vn
class of 1.0 IEC 62053-21/(Optational 0.5,0.2 IEC- 62053-22) Modbus Input Voltage Range : 18-520V (L-L) / 10V-300V (L-N)
communication on RS 485 is optional. Insulation Voltage : 2000V
Input Current : Ir, Iy, Ib
Features Input Current : 50mA-6A (Accuracy range)
• Simultaneous Display of Measured Quantity & Parameter Starting Current : 1-200mA (programmable)
• Trip Function enables user to have record of integration qty from a selected time CT Burden : 0.2VA max. per phase
• Auto scaling of Kilo Giga, Mega and decimal Point Current with stand : 10A continuous, 50A for 1 Second
Input Frequency : 40 to 70Hz
• Password protection for user programmable parameters
Auxiliary Supply : 35-300V AC/DC
• Modbus Communication on RS - 485 (Optional)
Auxiliary supply burden : <4VA
• Meter/Wiring configuration is field programmable as Star/Delta/Single Phase
Display : 3 Row 6 Digit (4 Alpha-numeric)
connection.
Display Scrolling : Automatic/Manual
• Accuracy Class 1.0 IEC 62053 - 21/ (Optional 0.5;0.2 IEC 62053-22)
Pulse Output Contact Rating : 50mA (Optional, Max. Pulse
• Selectable auto & manual scroll of display
width 250+-50ms 24VDC
Communication : Modbus Comm. on RS-485 (Optional)
Max Time to Reset Max Time to
V.PRIxA. CT Primary setting : 1A to 999kA
Max Reading the Integrator in Overflow in Month
PRIx1.732 CT Secondary setting : 1A to 10A
Run Hours at Full Scale
PT Primary setting : 50V to 999kV
1VA to 40KVA 999999.999K 100 Years 2.8 Years PT Secondary setting : 50V to 999 V
40KVA to 40MVA 999999.999K 100 Years 2.8 Years
Depends Upon
>40MVA 999999.999K 100 Years
Setting
Model Selection
ACE
ACE-1900
ACE-5555
ACE-2552
ACE-2555
ACE-6555
ACE-2442
ACE-1600
ACE-2341
ACE-1100
ACE-2441
ACE-4811
ACE-4411
Measurement Parameters
Basic
Voltage VLL, VLN
Line Current IR, IY, IB
Frequency Hz
Average I
Neutral Current Calculated
Unbalance %1 %V
* Application specific models can be ere ated.
Power
Apparent Power Va, Va1, Va2, Va3
Active Power W, W1, W2, W3
Power Factor Pf, Pf1, Pf2, Pf3
Reactive Power Var, Var1, Var2, Var3
Integration Present
Active Energy Wh
Reactive Energy ±Varh
Power Energy Vah
Run Hour RnHr
Load Hour Ldhr
Old
Active Energy Wh
Reactive Energy ±Varh
Power Energy Vah
Run Hour RnHr
Load Hour Ldhr
Trip
Active Energy Wh
Reactive Energy? ±Varh
Power Energy Vah
Run Hour RnHr
Load Hour Ldhr
THD V&l
Max. Demand MD
Relay Output 3 Relays
03
www.mrmprocom.com
Model Selection
FLY-1100
FLY-1103
FLY-1300
FLY-1400
FLY-1403
FLY-1900
FLY-2010
FLY-2041
FLY-2111
FLY-2412
FLY-2415
FLY-2811
FLY-2812
FLY-2552
Measurement Parameters FLY-2555
Basic
Voltage VLL, VLN
Line Current IR, IY, IB
Frequency Hz
Average I
Neutral Current Calculated FLY
Unbalance %1 %V
Phase Angle PA
Power
Apparent Power
Active Power
Power Factor
Reactive Power
Integration
Active Energy Wh
Reactive Energy ±Varh
Power Energy Vah
Run Hour RnHr
Load Hour Ldhr
Interrupts Nos.
Old
Active Energy Wh
Reactive Energy ±Varh
Power Energy Vah
Run Hour RnHr
Load Hour Ldhr
Interrupts Nos. Max Time to Max Time to
Resetthe Overflow in
Trip V.PRIxA.
Max Reading Integrator Month at Full
Active Energy Wh PRIx1.732 Scale
in Run Hours
Reactive Energy? ±Varh
Power Energy Vah 1VA to 40KVA 999999.999K 100 Years 28 Years
Run Hour RnHr 40KVA to
Load Hour Ldhr 999999.999K 100 Years 28 Years
40MVA
Interrupts Nos.
Depends Upon
THD V&l >40MVA 999999.999K 100 Years
Setting
04
GEM Introduction Technical Specification
GEM series meters are digital panel meter with 4 digit, 3 row seven segment Voltage : L-N, L-L
display. Three navigator keys & Seven Segment display simplifies Current : 11, 12, 13
Frequency : Hz
measurement Display & configuration of meter.
Run Hour : Hr.
Rpm : Rpm
Features Input Range
Voltage Range : 10-300 V(L-N)
• True RMS Measurement • Accuracy class 1.0 of reading
: 18-520 V(L-L)
• High glow display for distant viewing • Programmable PT & CT Ration Current Range : 50mA to 6.0AAC
• Auto Decimal & Kilo Select • SMPS based Aux. Supply Frequency Range : 40 to 70 Hz
• Programmable 1A/5A site selectable Starting Current : 5mA
Over Current : 10A Continuos
Current Withstand : 50Afor 3 Seconds
Voltage Withstand : 1000V
Run DC DC Over Voltage : 550 V(L-L)
Model Frequency RPM
hour Voltage Current Resolution : 4 digit display with auto
L-L L-N 11 12 13
decimal scrolling
GEM-1-V Display Scrolling : Automatic / Manual
GEM-3-V Accuracy : Class 1 or 0.5
GEM-1-1 Auxiliary Supply : 35-300V AC/DC
Temperature : -10 to 70* C
GEM-3-1 Storage : -20 to 75 • C
GEM-F Humidityfnon condensing) : Upto 85% RH
GEM-1-VIF Mounting : Panel Mount
GEM-3-VIF
GEM
GEM-1-G
GEM-3-G
GEM-3-V3
GEM-3-I3
GEM-DC-V
GEM-DC-I
GEM-FR
GEM-HR
TNY-2200A
TNY-2010
TNY-2310
TNY-2320
TNY-2330
TNY-2305
TNY-2335
TNY-2340
TNY-2411
TNY-2443
Measurement Parameters
Basic
Voltage VLL, VLN
Line Current IR, IY, IB
Frequency Hz
Average 1
Neutral Current Calculated
Phase Angle PA
Power
TNY Introduction
Apparent Power Va,Va1,Va2,Va3
TNY series meters are compact digital power meter, equipped with 4 digit, Active Power W,W1 ,W2,W3
3 row LED display. Three navigator keys & LED display simplifies meter Power Factor Pf,Pfl,Pf2,Pf3
configuration.
Integration
TNY series are available with accuracy class of 1.0 IEC6205321/
(Optational 0.5,0.2 IEC- 62053-22), Modbus Communication On RS Active Energy Wh
485/232 is Optional. Reactive Energy ±Varh
Power Energy Vah
Run Hour RnHr
Features Load Hour Ldhr
• Trip Function enables user to have record of integration qty. from a Interrupts Nos.
selected time Old
• Auto scaling of Kilo Giga, Mega and decimal Point
• Modbus Communication on RS - 485/ RS - 232 (Optional) Active Energy Wh
Reactive Energy ±Varh
• Meter / Wiring configuration is field programmable as Star/ Delta/ Power Energy Vah
Single Phase connection. Run Hour RnHr
• Accuracy Class 1.0 IEC 62053 - 21/ (Optional 0.5;0.2 IEC 62053-22) Load Hour Ldhr
• Selectable auto & manual scroll of display Interrupts Nos.
• Polycarbonate body THD V&I
• IP 65 from front
05
www.mrmprocom.com
PROTECTION RELAYS
Introduction
• The COP Series of Protection Relays are Designed Using Numerical Technology (Discrete Fast Fourier
Transformation.) Reliable & Accurate Tripping is Ensured by Deploying Digital Technique Using DSP. High Sampling
Rate of 2000 Sample/Sec Ensures Actual Reproduction of Waveform.
• User Friendly HMI Eases Configuration & Operating Procedure of Relay
• User Programmable Digital Output Provides Flexibility in Selecting Alarm Contact.
• 2 x16 Row Backlit LCD Display
• Auxiliary supply H (50 to 300 VAC/ DC) L (8 to 35 VDC/DC)
• Display in Primary/Secondary Value
• Housing 96 X 96 mm
Two Stage Under and Over IDMT Over Current Earth Fault IDMT Over Current with S/C Earth Fault Protection Relay Restricted Earth Fault &
Voltage Relay with S/C Protection Relay Protection Relay Protection Relay
ANSI : 27,59 ANSI : 50, 51 & 50N, 51N ANSI : 50, 51 ANSI : 50N, 51N ANSI : 64R
l>: 0.1- 2.5 I/In l>: 0.1- 2.5 I/In le>: 0.05-2.5 I/In le>: 0.05-2.5 I/In
O/V : 0.50-1.7 V/Vn
l»: 0.5-12.0 I/In l»: 0.5-12.0 I/In le»: 0.3-4.0 I/In le»: 0.3-4.0 I/In
Characteristic Characteristic
DEFT DEFT
le>: 0.05-2.5 I/In EINV EINV
U/V : 0.50-1.7 V/Vn Characteristic Define Time
le>>: 0.3-4.0 I/In NINV 0.6 NINV 0.6
NINV 1.3 NINV 1.3
NINV 3.0 NINV 3.0
Timer: 5 Nos Timer: 5 Nos Timer: 3 Nos Timer: 3 Nos Timer: 3 Nos
Contact: 1 Trip, 3 Contact: 1 Trip, 3 Contact: 1 Trip, 3 Contact: 1 Trip, 3 Contact: 1 Trip, 3
Programmable Programmable Programmable Programmable Programmable
Two Stage Under & Over Reverse & Low Forward Combine Two Stage Voltage & Combine Two Stage Voltage, Two Trip Circuit Supervision Relay
Frequency Relay Power Relay Two Stage Frequency Stage Frequency, over current
Protection Relay short circuit & earth fault Relay
ANSI : 81 0 & 81 U ANSI : 32 R ANSI: 27, 59 & 81O & 81U ANSI: 27, 59 &810 & ANSI : 74TC
81U 50, 51& 50n, 51 n
Rated Voltage
l> : 0.1-2.51/In
.24VDC
O/F : 45-70 HZ l» : 0.5-12.01/In
U/F : 45-70 HZ Fpr: 0.05-0.5 P/Pn .48VDC
U/F : 45-70 HZ le> : 0.05-2.51/In
.110VDC
le» : 0.3-4.01/In
.220VDC
06
NUMERICAL FEEDER PROTECTION RELAYS
Introduction
• The COP Plus Series of Feeder Protection Relays are Designed Using Numerical
Technology (Discrete Fast Fourier Transformation.) Reliable & Accurate Tripping is
Ensured by Deploying Digital Technique Using DSP. High Sampling Rate of 2000
Sample/Sec Ensures Actual Reproduction of Waveform.
• User Friendly HMI Eases Configuration & Operating Procedure of Relay
• User Programmable Digital Output Provides Flexibility in Selecting Alarm Contact.
• In Addition to Default USB Part one Optional RS-485 Port is also Provided.
Introduction
• Over Current Protection
• Short Port Current Protection
• Earth Fault Protection
Features • High set Earth Fault Protection
• Ground Fault Protection
• 128x64 Pixel Graghical/display • High Ground Fault Protection
• Event Recording • Trip Current Supervision
• Fault Date Recording • Circuit Breaker Failure Protection
• RTC Stamp on Fault & Event • Multiple Shot Auto Recloser
• Five Digital Input • Lock Out
• Site Selectable 1A/5A CT Secondary Current • Tripping Characterstics
• Wide Auxiliary Supply(20 To 300 VDC/50-300VAC) Inverse Time - Extremely Inverse
• Display in Primary/Secondary Values Inverse Time - Very Inverse
• Wide Setting Range With Fine Setting Steps Inverse Time - Normal Inverse 0.6
• Front USB Port Inverse Time - Normal Inverse 1.3
• RS-485 communication Port with MODBUS Inverse Time - Normal Inverse 3.0
protocol • Selective Earth/ground Fault Blocking In Case of Three Phase Shorting
COP+IEGK
COP+IEG
COP+IEK
COP+IK
COP+IE
ANSI
PROTECTION
COP+I
Code
07
www.mrmprocom.com
Protection
Time Delay Reset Type Supply Contact Type Model No.
Variable Setting Fixed Setting
1C/O VMP 32A2-1
Single Phase 3P-3W
2C/O VMP 32A2-2
Prevention & Phase Trip Time <100ms Auto Reset
Sequence 1C/O VMP 42A2-1
3P-3W
2C/O VMP 42A2-2
1C/O
Adjustable 3P-3W
Single Phase Separate 2C/O VMR 39A0-2
Over Voltage Auto Reset
Prevention Trip Delay 1C/O VMR 49A0-1
(.2-10sec) 3P-3W
2C/O VMR 49A0-2
08
VOLTAGE MONITORING & PHASE SEQUENCE RELAYS
Protection Contact
Time Delay Reset Type Supply Model No.
Type
Variable Setting Fixed Setting
1C/O VMR 31M4-1
Fix Trip Delay 3P-3W
Single Phase (5s) & Manual 2C/O VMR 31M4-2
Under + Over Voltage
Prevention Fix Reset Reset 1C/O VMR 41M4-1
Delay (5s) 3P-4W
2C/O VMR 41M4-2
09
www.mrmprocom.com
CURRENT TRANSFORMERS
Current Transformer: Procom Manufacture Wide Range of LT Current Transformer For Rating Upto 3000A that Includes.
• Rectangular Molded Current Transformer • Protection Class IP - 20
• Round Molded Current Transformer • Dual Terminal For Fixing CT Shorting Link
• Rasing Cast LT Current Transformer • Bus Bar Clamp
• Wound Primary Current Transformer • Easy To Moun
• Core Balance Current Transformer • Finger Safe Terminal Cover
• Nylon Housing UL 94-V2
Various Models are Available to Suit Different Mounting & Busbar Arrangement
S2
400 15 1000 20
Accessaries : Busbar Holder 1 No. , Screw Cap 2 No. , Screw 2 No. Mounting Bracket 2 No.
10
TYPE - PRO9530B6215 Accuracy Class 1.0 (0.5 On Request)
Primary Current VA Rating Primary Current VA Rating
200 2.75 800 15
250 5 1000 20
300 5 1200 20
400 7.5 1250 20
500 15 1500 20
600 15 1600 20
750 15 2000 20
Accessaries : Busbar Holder 1 No. , Screw Cap 2 No. , Screw 2 No. Mounting Bracket 2 No.
100/5 31 75 50 96 2.5 5
150/5 31 75 50 96 5 5
200/5 31 75 50 96 5/10 5/10
200/5 43 92 41 113 5 5110/15
200/5 58 100 41 121 5 5/10/15
250/5 43 92 41 113 5 5/10
250/5 58 100 41 121 5 5/10/15
300/5 43 92 41 113 5/10 5/10/15 F
300/5 58 100 41 121 5/10 5/10/15
D
E
400/5 43 92 41 113 5/10 5/10
400/5 58 100 41 121 5/10 5/10
500/5 58 100 41 121 5/10/15 5/10/15 PROCOM
R
C
S2 S1
600/5 58 100 41 121 5/10/15 5/10/15
800/5 72 110 41 131 5/10/15 5/10/15 A
P2
800/5 85 134 30 155 5/10/15 5/10/15
1000/5 72 110 41 131 5/10/15 5/10/15
B
1000/5 85 134 30 155 5/10/15 5/10/15
1200/5 85 134 30 155 5 10/15
Dimension Drawing :
1200/5 113 160 40 181 15 15
1500/5 113 160 40 181 15 15 CT Type A (ID) B (OD) C (H) D E F (W)
1600/5 113 160 40 181 15 15 1. 31 75 100 50 20 50
1800/5 113 160 40 181 15 15 2. 43 92 117 50 20 41
2000/5 113 160 40 181 15 15 3. 58 100 125 50 20 41.5
2400/5 130 165 30 186 15 15 4. 72 110 135 50 20 41
2500/5 130 165 30 186 15 15 5. 85 134 159 50 20 30
3000/5 130 165 30 186 15 15 6. 113 160 185 50 20 40
3200/5 150 190 35 211 15 15 7. 130 165 190 50 20 30
4000/5 200 235 35 256 15 15 8. 150 190 215 50 20 35
5000/5 200 235 35 256 15 15 9. 200 235 260 50 20 35
11
www.mrmprocom.com
100/5 30 80 80 45 55 5 5
100/5 30 90 90 50 55 10 10
150/5 30 80 80 40 55 5 5
150/5 30 80 80 50 55 10 10
200/5 35 80 80 40 55 5/10 5/10
200/5 35 80 80 50 55 15 15
250/5 45 90 90 40 55 5/ 10 5/10
250/5 45 90 90 50 55 15 15
300/5 55 90 90 40 55 5/10 5/10
300/5 55 90 90 45 55 15 15
400/15 55 90 90 35 55 5 5
400/5 55 90 90 40 55 10 10
400/5 55 90 90 45 55 15 15
500/5 55 90 90 35 55 5/ 10 5/10
500/5 55 90 90 40 55 15 15
600/5 55 90 90 35 55 5/10 5/10
600/5 55 90 90 40 55 15 15
800/5 70 105 105 35 85 5 5
800/5 70 105 105 40 85 10 10
800/5 70 105 105 45 85 15 15
12
RESIN CAST PROTECTION CLASS CURRENT TRANSFORMER
Resin Cast CT
47.5 55 72.5
20.5
20.5 20.5
A B C
13
www.mrmprocom.com
AMF CONTROLLERS
Protection:
Lube Oil Pressure High Water Temperature Radiator Water Level, Emergency off, Low Fuel,
Charging Alt/V beet Failure.
Measurement Display :
Oil Pressure, Water Temperature, Fuel Level,
RPM, Run hour, Battery Voltage, Service Due Hour.
Digital Input:
Remote Start, Remote Stop, Protection Disable/Debar.
14
DGC-11 AMF CONTROLLERS
Operation Mode : Auto, Semi Auto, Manual, Test & Off Mode
Features : Configurable Three Phase/ Single Phase Mains & DG with Load
Management
Measurement : mains & DG Voltage, Current, KWH, KW, PF, Frequency, DC Battery
Voltage, Sensor Data, Rpm Running Hr. Service Due Alarm
Protection : External Fault Input 4 Nos., Over-speed, Over & Under Voltage, Over
Load, Emergency Stop, Fail to Start, Fail To Stop, Chg/ V-Belt
Battery Supply : 7-35 VDC
Housing : DIN Standard 186x96 MM
MANUAL DG
15
www.mrmprocom.com
BUSBAR SUPPORTS
BUS BAR SUPPORT CONICAL BUS BAR SUPPORT HEXAGONAL
PRODUCT CODE INSERT DIMENSION IN MM PRODUCT INSERT DIMENSION IN MM
CODE
D.T. D.B. H Hb
BIC-25-5 M5 19 25 25 10 D.T D.B H Hb
BIC-25-6 M6 19 25 25 10 BIH-25-5 M5 19 25 25 10
BIC-30-6 M6 25 30 30 10 BIH-25-6 M6 19 25 25 10
BIC-35-6 M6 28 35 35 12 BIH-30-6 M6 25 30 30 10
BIC-40-6 M6 33 40 40 12 BIH-35-6 M6 28 35 35 10
BIC-30-8 M8 25 30 30 10 BIH-40-6 M6 33 40 40 12
BIC-35-8 M8 28 35 35 12 BIH-30-8 M8 25 30 30 10
BIC-40-8 M8 40 33 40 12 BIH-35-8 M8 28 35 35 10
BIC-45-8 M8 33 40 45 12 BIH-40-8 M8 40 33 40 12
BIC-40-10 M10 33 40 40 12 BIH-45-8 M8 33 40 45 12
BIC-50-10 M10 40 50 50 17
BIH-40-10 M10 33 40 40 17
BIC-60-10 M10 40 50 60 17
BIH-50-10 M10 40 50 50 17
BIC-70-10 M10 40 50 70 20
BIH-60-10 M10 40 50 60 17
BIC-80-10 M10 40 50 80 20
BIH-70-10 M10 40 50 70 17
BIC-50-12 M12 40 50 50 20
BIH-80-10 M10 40 50 80 17
BIC-60-12 M12 40 50 60 20
BIH-50-12 M12 40 50 50 17
BIC-65-12 M12 40 50 65 20
BIH-60-12 M12 40 50 60 17
BIC-70-12 M12 40 50 70 20
BIC-75-12 M12 45 55 75 20
BIC-80-12 M12 45 55 80 20
D.T.
Hb Hb
D.B.
L-TYPE SUPPORT
40 10
PRODUCT CODE HEIGHT(H) MM
PRO-ML-60 60
60
PRO-ML-85 85
12
10
PRO-ML-105 105
30 50 30
PRO-ML-125 125
Front view Right view
PRO-ML-150 150
16
TWO WAY FINGER SUPPORT
PRODUCT CODE BUS BAR DIMENSION IN MM
SIZE
A B C D E F
PRO-M-206-W 6 MM x 2 BAR 7.0 60 32 14 10 5.5
PRO-M-210-W 10 MM x 2 BAR 11.2 60 32 14 10 9
PRO-M-212-W 12 MM x 2 BAR 13.2 60 32 14 10 11
PRO-M-206-K 6 MM x 2 BAR 7.0 70 40 20 16 5.5
PRO-M-210-K 10 MM x 2 BAR 11.2 70 40 20 16 9
PRO-M-212-K 12 MM x 2 BAR 13.7 70 40 20 16 11
F D
POWER TERMINAL
17
www.mrmprocom.com
PREPAID METER
Introduction:
Prepaid Meter is a user friendly meter and having compact wall mounting
design, equipped with 10 digit, 2 row LCD display. Top row diaplays
measurements and bottom row displays the parameters. Two navigator
keys & LCD display simplifies meter configuration.
Prepaid meter is a three phase dual source meter and can measure upto
80Amps whole current. Prepaid meter is available with accuracy class of
1.0 as per IS13779 and communication through RS 485.
Technical Specifications
Accuracy : Class 1.0
Input Voltage : VR, VY, VB, VN
Referance Voltage : 230 V (L-N)
Input Current : IR, IY, IB
Input Current : 10A Ibasic, 60A Imax.
Burden at Current circuit : <2.5 VA per phase
Burden at Voltage circuit : 10VA per phase
Current withstand : 60A continuous, 80A for 1 second
Input Frequency : 40 to 70 Hz
Display : 2Row 10Digit (LCD)
Display Scrolling : Automatic/ Manual
Communication : RS-485
Rs485 Option:
• Optically isolated connection
• Baud Rates up to 19200
• Up to 247 Nodes on a single network
• Modified Modbus on Rs485
Features:
Software Features:
• Customisation of meter parameters: • Critical data such Billing data, consumption, balance
(I) Customer Id available etc are avaiable both on Server and meter.
(II) Customer Name and Add
(III) Customer Mobile number
• Data is not lost due Failure of either server or meter
• Data transfer to Meter on RS485 port is secured by
Updating encryption AES-128 to prevent tampering and hacking of the
• Tariff for EB and DG
meter.
• Load sanctioned for EB and DG
• Holiday calendar • No separate EB and DG recharging.
• Weekly off • Protects your equipment against overload/over voltage.
• Happy Hours
• Billing on KVAh or Kwh • Displays and communicates Balance, VLL, VLN, Amp, Hz,
• Maintenance charges W, PF, VA, Kwh/KVAh(EB and DG).
• Additional Charges
• Indication for Low Balance.
• etc
• Currency based recharging for EB, DG, Fixed Charges and
Recharges Maintenance Charges.
• Record of the recharges along with the operator issuing the recharge
• Maintenance charge deduction on daily or monthly baisis
Logging meter data • History of last 12 Recharges.
• Meter can be read at a user defined duration and the data is logged in the
• Last 6 months of consumption records.
server
• Downloading the data from the meter for analysis and cross checking • Last 180 days daily consumption log
• 30 days calendar for holiday cut off prevention
Email/SMS
• User defined frequency for these messages • Programmable happy hours
Amount available • Programmable weekly off
Recharge done
Warning on reduced balances • Remote display unit allowing customer to monitor
Optional generation of monthly billing consumption.
User defined requirements • Currency based recharging for EB, DG, Fixed Charges and
Security
• Separate logging for each operator
Maintenance Charges.
• AES-128 encrypted data transfer to prevent spying
18
MANUAL PANEL CONTROLLERS / RELAY CARD / MCCB COVER
Procom provides all the shelf solution for simple manual control panal & typical AMFcontrol
panel. Procom can also customize the panal dismension and color as per customer requirement.
All the panels are CNG fabricated with seven tank power coated for easier identification
computerized level marking on wires. All component of the panal are mounted on threaded studs
for easier replacement. The manufacturing range is 5 Kva to 320 Kva panels for prestigious
customers.
RELAY CARD
MCCB Cover
Accessaries : Busbar Holder 1 No. , Screw Cap 2 No. , Screw 2 No. Mounting Bracket 2 No. PRO 400
19