Sei sulla pagina 1di 10

A.

Galvanized Agitator
1. With Agitation
Time Cooling Water Temp of
Liquid in
(minutes) Inlet Temp Outlet Temp Flow Rate Vessel
0 28.3 43.6 2.8 105
3 28.3 36.3 2.8 87
6 28.3 33.1 2.8 85 1

9 28.3 32 2.8 71
12 28.3 31.8 2.7 68 1

15 28.3 31.4 2.6 62

temperature
Lead lined Agitator
Time Cooling Water Temp of
Liquid in
(minutes) Inlet Temp Outlet Temp Flow Rate Vessel
0 28.3 46 2.9 95
3 28.3 34.3 2.9 78
6 28.3 31.9 2.9 70
9 28.3 31.2 2.9 60
12 28.3 30.9 2.8 58
15 28.3 30.7 2.8 57

Galvanized Agitator
Without Agitation

Time Cooling Water Temp of


Liquid in
(minutes) Inlet Temp Outlet Temp Flow Rate Vessel
0 28.3 32.2 2.4 102
3 28.3 31.4 2.4 97
6 28.3 29.9 2.4 92
9 28.3 29.7 1.9 90
12 28.3 29.33 1.9 88
15 28.3 29.1 1.9 87
temperature

Lead-Lined Agitator
Without Agitation
Time Cooling Water Temp of
Liquid in
(minutes) Inlet Temp Outlet Temp Flow Rate Vessel
0 28.3 31 2.5 110
3 28.3 29.4 2.4 100
6 28.3 29.2 2.5 98
9 28.3 28.7 1.9 95
12 28.3 28.2 1.9 93
15 28.3 28 1.9 90
cooling of a liquid with agitati on
Gal va ni zed Agi tator Lead Lined Agi tator
120

100

80
temperature

60

40

20

0
0 2 4 6 8 10 12 14 16
time

cooling of a liquid without agitati on


Gal va ni zed Agi tator Lead Li ned Agi tator
120

100

80
temperature

60

40

20

0
0 2 4 6 8 10 12 14 16
time
20

0
0 2 4 6 8 10 12 14 16
time
12 14 16
A. Galvanized Agitator
1. With Agitation
Time Steam
heati ng of
(Minutes) Inlet Condensate Temperature
of the Vessel Gal va n
Volume 140
Temp Pressure Temp
(ml) 120
0 125 25 0 85.3 30 100

temperature
3 125 25 610 76.1 70 80
6 125 15 150 52.1 82 60
9 125 10 65 48.2 91 40
12 125 65 2110 78.6 120 20
15 125 55 400 74.2 108 0
0 2 4

A. Lead-lined Agitator
1. With Agitation
Time Steam
Temperature
(Minutes) Inlet Condensate of the Vessel
Temp Pressure Volume Temp
0 125 20 0 0 50
3 125 30 500 74.1 64
6 125 30 600 78.2 91
9 125 23 400 77.6 95
12 125 70 930 85.8 103
15 125 65 365 74.5 114

Galvanized Iron
1. Without Agitation heati ng of a liquid witho
Time Steam Gal va ni zed Iron Lea d-L
Temperature
(Minutes) Inlet Condensate
of the120Vessel
Temp Pressure Volume Temp 100
0 125 30 0 0 30
80
temperature

3 125 60 170 56 65.5


60
6 125 90 195 55.6 76
40
9 125 90 186 54.7 91
12 125 80 1110 53.2 20
102
15 125 89 980 52.6 105.50
0 2 4 6 8
time
t
20

0
0 2 4 6 8
time

Lead-Lined Agitator
Time Steam
Temperature
(Minutes) Inlet Condensate
of the Vessel
Temp Pressure Volume Temp
0 125 25 0 0 30
3 125 59 710 58.4 87
6 125 40 430 57.4 102.5
9 125 30 560 56.7 102.5
12 125 60 520 53.8 102.5
15 125 50 670 52 109
heati ng of a liquid with agitati on
Gal va ni zed Iron Lea d Li ned Agi tator
140
120
100
80
60
40
20
0
0 2 4 6 8 10 12 14 16
time

f a liquid without agitati on


al va ni zed Iron Lea d-Li ned Agi tator

4 6 8 10 12 14 16
time
4 6 8 10 12 14 16
time

Potrebbero piacerti anche