Sei sulla pagina 1di 6

4-Port Antenna R1 Y1

Frequency Range 790–960 1710–2690


Dual Polarization X X
HPBW 65° 65°
Adjust. Electr. DT 0°–16° 2°–10°
set by hand or by optional RCU (Remote Control Unit)

4-Port Antenna 790–960/1710–2690 65°/65° 15/17.5dBi 0°–16°/2°–10°T


Type No. 80010664
Lowband R1, connector 1– 2
790 – 960
Frequency range MHz 790 – 862 824 – 894 880 – 960
Polarization ° +45, –45 +45, –45 +45, –45
Average gain dBi 14.5 ... 14.4 ... 14.2 14.6 ... 14.5 ... 14.3 14.8 ... 14.6 ... 14.4
Tilt ° 0 ... 8 ... 16 0 ... 8 ... 16 0 ... 8 ... 16
Horizontal Pattern:
Half-power beam width ° 69 68 67°
Front-to-back ratio, copolar (180°±30°) dB > 25 > 25 > 25
Cross polar ratio
Maindirection 0° dB Typically: 25 Typically: 25 Typically: 25
Sector ±60° > 10 >9 >8
Horizontal Pattern:
Half-power beam width ° 16.5 16.0 15.5
Electrical tilt ° 0–16, continuously adjustable
Sidelobe suppression for first sidelobe °T 0 ... 8 ... 16 0 ... 8 ... 16 0 ... 8 ... 16
above main beam dB 16 ... 15 ... 15 16 ... 15 ... 15 15 ... 15 ... 14
Impedance Ω 50
VSWR < 1.5
Isolation: Intrasystem dB > 30
Isolation: Intersystem dB > 30 (698–960 // 1710–2690 MHz)
Intermodulation IM3 dBc < –150 (2 x 43 dBm carrier)
Max. effective power per port 300 (at 50 °C ambient temperature)
W
Max. effective power for the antenna 600 (at 50 °C ambient temperature)
Subject to alteration.
936.4850/b

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 80010664 Page 1 of 3
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
4-Port Antenna

Highband Y1, connector 3 – 4


1710 – 2690
Frequency range MHz 1710 – 1880 1850 – 1990 1920 – 2170 2300 – 2400 2490 – 2690
Polarization ° +45, –45 +45, –45 +45, –45 +45, –45 +45, –45
Average gain dBi 17.2 ... 17.3 ... 16.8 17.4 ... 17.4 ... 16.9 17.6 ... 17.7 ... 17.0 17.0 ... 16.8 ... 16.0 17.2 ... 17.3 ... 16.7
Tilt ° 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10
Horizontal Pattern:
Half-power beam width ° 63 64 66 73 65
Front-to-back ratio, copolar (180°±30°) dB > 25 > 28 > 29 > 26 > 25
Cross polar ratio dB
Maindirection 0° Typically: 18 > 20 20 23 23
Sector ±60° >9 > 10 > 10 > 10 >8
Horizontal Pattern:
Half-power beam width ° 6.2 5.8 5.6 5.4 4.8
Electrical tilt ° 2–10, continuously adjustable
Sidelobe suppression for first sidelobe °T 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10 2 ... 6 ... 10
above main beam dB 14 ... 15 ... 16 14 ... 15 ... 17 15 ... 16 ... 17 17 ... 18 ... 18 15 ... 17 ... 18
Impedance Ω 50
VSWR < 1.5
Isolation: Intrasystem dB > 28 > 30
Isolation: Intersystem dB > 30 (790–960 // 1710–2690 MHz)
Intermodulation IM3 dBc < –150 (2 x 43 dBm carrier)
Max. effective power per port W 200 (at 50 °C ambient temperature)
Max. effective power for the antenna 400 (at 50 °C ambient temperature)

Mechanical specifications

Input 4 x 7-16 female (long neck)


Connector position Bottom
Adjustment mechanism 2 x, Position bottom
continuously adjustable
Subject to alteration.

Wind load (at Rated N | lbf Frontal: 260 | 58


Wind Speed: 150 km/h) Maximal: 415 | 93
Max. wind velocity km/h 200
mph 124
Height / width / depth mm 1403 / 300 / 152
Y1 inches 55.2 / 11.8 / 6.0
R1 Category of
M (Medium)
mounting hardware
936.4850/b

Weight kg 18 / 20 (clamps incl.)


Correlation Table lb 39.7 / 44.1 (clamps incl.)
Packing size mm 1726 x 322 x 190
Frequency range Array Connector inches 68.0 x 12.7 x 7.5
Scope of supply Panel and 2 units of clamps
790– 960 MHz R1 1–2 for 42 – 115 mm |
1710–2690 MHz Y1 3–4 1.7– 4.5 inches diameter

All specifications are subject to change without notice.


Page 2 of 3 80010664 The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Accessories
General Information

Accessories (order separately if required) 2) 1) ’ 9 | 0.4


1) 2) 64 | 2.5
Remarks Weight approx. Units per
Type No. Description
mm | inches kg | lb antenna

85010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 2
85010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2
737978 1 downtilt kit Downtilt angle: 0° – 15° 2.3 | 5.1 1
Accessories (included in the scope of supply)
738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.

1403 | 55.2
1433 | 56.4
1473 | 58.0
Wall mounting: No additional mounting kit needed.

Material: Reflector screen: Aluminum.


Fiberglass housing: It covers totally the internal antenna components.
The special design reduces the sealing areas to a minimum and
guarantees the best weather protection. Fiberglass material guarantees
optimum performance with regards to stability, stiffness, UV resistance
and painting. The color of the radome is light grey.
All nuts and bolts: Stainless steel or hot-dip galvanized steel.

Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.

Adjustment mechanism
with integrated scale

All dimensions
in mm | inches

Layout of interface:

t 790-960 1710-2690
Til Ti
lt
152 | 6.0 *

173 | 6.8 *
108 | 4.3
49 | 1.9
46 | 1.8
Subject to alteration.

101 | 4.0
221 | 8.7
244 | 9.6
936.4850/b

300 | 11.8 *

Bottom view
* Dimensions refer to radome
All dimensions in mm | inches

Any previous data sheet issues have now become invalid.

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 80010664 Page 3 of 3
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Mounting Hardware
Clamp Included in the Scope of Supply

Suitable for mast diameter (mm) 42 – 115


[inches] [1.65 – 4.53]
Antenna – mast distance (mm) 20 – 25
[inches] [0.79 – 0.98]
Material of clamp and screws Hot-dip galvanized steel / stainless steel
Weight (kg) 1.1
[lb] [2.43]

152 [5.98]

100 [3.94]

[0.79–0.98]
40 [1.57]
72 [2.83]

20–25
40 [1.57]

15
2–1
’ 4 4.53]
5–
[1.6

M10 ‰MA = 25 Nm

M8 ‰MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]

20–25
[0.79–0.98]
Subject to alteration.
936.3920/c

Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 738546 Page 1 of 1
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Instructions
for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

1
2

2
➀ Twist protection. ➀ Thread for fixing the protective To set the downtilt angle exactly,
➁ Downtilt spindle with integrated cap or the RCU (Remote Control you must look horizontally at the
scale. Unit). scale. The lower edge of the gear-
➁ Gearwheel for RCU power drive. wheel must be used for alignment.

Manual adjustment procedure:

0° – max.°

0° – max.°

Remove the protective cap and the Set downtilt angle by rotating the Screw on the twist protection and
twist protection completely. gearwheel. the protective cap again.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:


Subject to alteration.
936.4037/a

For a description of RCU installation please refer to the respective data sheet.
All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com Page 1 of 2
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Instructions
for Feederline and RCU Installation
for Antennas
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.

Description of bottom end cap (exemplary picture):

Adjustment mechanism
(protective cap removed) Ventilation hole

Spindle with tilting scale

Colour coding:
Correlation of each RF input to:
– the corresponding adjustment mechanism
7-16 female (long neck) – the frequency range
– the polarization

Installation of the feederline connector and RCU (optional):


In order to protect the adjustment mechanism, the protective caps have to be attached during
feederline installation!
Kathrein installation set: Type No. 85010077
Set has to be ordered separately!
Set consists of three spanners of divers width
27, 32 and 41 mm | 1.1, 1.3 and 1.6 inches
1/2˝ square actuation
according to
DIN 3120 Form C

32 | 1.3
Subject to alteration.

Carefully place the connector and After feederline installation, the


fix the nut using a torque-wrench optional remote control units
(according to the manufacturers (RCUs) can be mounted. .6
|1
27

guidelines). 41
| 1.
1

All dimensions in mm | inches


936.4037/a

These tools are suitable for 7-16 connectors with a wrench size of
27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a
wrench size of 41 mm | 1.6 inches.
Tighten nuts within a torque range of 25 – 33 Nm depending on
connector manufacturers’ specifications, respectively the RCU nut
with a torque range of 15 – 18 Nm.

All specifications are subject to change without notice.


Page 2 of 2 The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com