Sei sulla pagina 1di 3

C .

Energi

1. Boiler
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 499,15)K
1 𝑀𝑊
= 20928 Kj /s| 1000 𝐾𝑗/𝑠|
= 20,29 Mw

2. Turbin ke-1
Dik : p = 29 bar
Interpolasi suhu
𝑋−𝑋1
Y =| | (Y2 – Y1 ) + Y1
𝑋2−𝑋1
28−25
=| |(233,9 – 224,0) + 224,0
30−25
4
= 5 (9,9) + 224,0
= 231, 920 C
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 505,07)K
1 𝑀𝑊
= 20475,95 Kj /s| 1000 𝐾𝑗/𝑠|
= 20,47 Mw

3. Turbin ke-2
Dik : p = 11,5 bar
Interpolasi suhu
𝑋−𝑋1
Y =| 𝑋2−𝑋1| (Y2 – Y1 ) + Y1
11,5−10
=| |(198,3 – 179,9 ) + 179,9
15−10
1,5
= 5
(18,4) + 179,9
= 189,420 C
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 458,57)K
1 𝑀𝑊
= 24027,62 Kj /s| |
1000 𝐾𝑗/𝑠
= 24,02 Mw

4. Turbin ke-3
Dik : p = 3,75 bar -> 375 kpa
Interpolasi suhu
𝑋−𝑋1
Y =| | (Y2 – Y1 ) + Y1
𝑋2−𝑋1
3,75−3,50
= | 4,00−3,50 |(143,6 – 138,6) + 138,6
0,25
= 0,5 (5) + 138,6
= 141,10 C
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 414,25)K
1 𝑀𝑊
= 27412,78 Kj /s| 1000 𝐾𝑗/𝑠|
= 27,412 Mw

5. Turbin ke-4
Dik : p = 387 bar -> 0,87 kpa
Interpolasi suhu
𝑋−𝑋1
Y =| 𝑋2−𝑋1| (Y2 – Y1 ) + Y1
0,87−0,80
=| |(96,71 – 93,50) + 93,50
0,90−0,80
0,07
= 0,10
(3,21) + 93,50
= 95,7470 C
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 368,89)K
1 𝑀𝑊
= 53791,37 Kj /s| 1000 𝐾𝑗/𝑠|
= 53,79 Mw

6. Turbin ke-5
Dik : p = 0,1 bar -> 10 kpa
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (773,15 – 318,96)K
1 𝑀𝑊
= 34691,03 Kj /s| |
1000 𝐾𝑗/𝑠
= 34,69 Mw

7. Kondensor
Dik : p1 = 0,1 bar -> 10 kpa
P2 = 0,1 bar -> 10 kpa
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (318,96 – 318,96)K
= 0 Mw

8. Condensate Pump
Dik : p = 0,1 bar -> 10 kpa
T1 = 318,96 K T2 = 919,13 K
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (319,15 – 318,96)K
1 𝑀𝑊
= 14,51 Kj /s| |
1000 𝐾𝑗/𝑠
= 0,0145 Mw

9. Preheater ke - 1
Dik : in -> 460 C = 319,15 K
0,87 Bar
Out -> 314,15 K
Interpolasi suhu
𝑋−𝑋1
Y =| 𝑋2−𝑋1| (Y2 – Y1 ) + Y1
0,87−0,80
= | 0,90−0,80 |(96,71 – 93,50) + 93,50
0,07
= 0,10 (3,21) + 93,50
= 95,7470 C
Q = m. cp . △dt
= 76,38 . 1,00 Kj/Kg.K (687,7 – 314,15)K
1 𝑀𝑊
= 28531,74 Kj /s| 1000 𝐾𝑗/𝑠|
= 28,53 Mw

Potrebbero piacerti anche